Search results for: exclusive HPLC
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 636

Search results for: exclusive HPLC

606 Parameters of Validation Method of Determining Polycyclic Aromatic Hydrocarbons in Drinking Water by High Performance Liquid Chromatography

Authors: Jonida Canaj

Abstract:

A simple method of extraction and determination of fifteen priority polycyclic aromatic hydrocarbons (PAHs) from drinking water using high performance liquid chromatography (HPLC) has been validated with limits of detection (LOD) and limits of quantification (LOQ), method recovery and reproducibility, and other factors. HPLC parameters, such as mobile phase composition and flow standardized for determination of PAHs using fluorescent detector (FLD). PAH was carried out by liquid-liquid extraction using dichloromethane. Linearity of calibration curves was good for all PAH (R², 0.9954-1.0000) in the concentration range 0.1-100 ppb. Analysis of standard spiked water samples resulted in good recoveries between 78.5-150%(0.1ppb) and 93.04-137.47% (10ppb). The estimated LOD and LOQ ranged between 0.0018-0.98 ppb. The method described has been used for determination of the fifteen PAHs contents in drinking water samples.

Keywords: high performance liquid chromatography, HPLC, method validation, polycyclic aromatic hydrocarbons, PAHs, water

Procedia PDF Downloads 104
605 Effectiveness of Educational and Supportive Interventions for Primiparous Women on Breastfeeding Outcomes: A Systematic Review and Meta-Analysis

Authors: Mei Sze Wong, Huanyu Mou, Wai-Tong Chien

Abstract:

Background: Breastmilk is the most nutritious food for infants to support their growth and protect them from infection. Therefore, breastfeeding promotion is an important topic for infant health; whereas, different educational and supportive approaches to interventions have been prompted and targeted at antenatal, postnatal, or both periods to promote and sustain exclusive breastfeeding. This systematic review aimed to identify the effective approaches of educational and supportive interventions to improve breastfeeding. Outcome measures were exclusive breastfeeding, partial breastfeeding, and breastfeeding self-efficacy, being analyzed in terms of ≤ 2 months, 3-5 months, and ≥ 6 months postpartum. Method: Eleven electronic databases and the reference lists of eligible articles were searched. English or Chinese articles of randomized controlled trials on educational and supportive intervention with the above breastfeeding outcomes over recent 20 years were searched. Quality appraisal and risk of bias of the studies were checked by Effective Public Health Practice Project tool and Revised Cochrane risk-of-bias tool, respectively. Results: 13 articles that met the inclusion criteria were included; and they had acceptable quality and risk of bias. The optimal structure, format, and delivery of the interventions significantly increased exclusive breastfeeding rate at ≤ 2 months and ≥ 6 months and breastfeeding self-efficacy at ≤ 2 months included: (a) delivering from antenatal to postnatal period, (b) multicomponent involving antenatal group education, postnatal individual breastfeeding coaching and telephone follow-ups, (c) both individual and group basis, (d) being guided by self-efficacy theory, and (e) having ≥ 3 sessions. Conclusion: The findings showed multicomponent theory-based interventions with ≥ 3 sessions that delivered across antenatal and postnatal period; using both face-to-face teaching and telephone follow-ups can be useful to enhance exclusive breastfeeding rate for more than 6 months and breastfeeding self-efficacy over the first two months of postpartum.

Keywords: breastfeeding self-efficacy, education, exclusive breastfeeding, primiparous, support

Procedia PDF Downloads 137
604 RP-HPLC Method Development and Its Validation for Simultaneous Estimation of Metoprolol Succinate and Olmesartan Medoxomil Combination in Bulk and Tablet Dosage Form

Authors: S. Jain, R. Savalia, V. Saini

Abstract:

A simple, accurate, precise, sensitive and specific RP-HPLC method was developed and validated for simultaneous estimation of Metoprolol Succinate and Olmesartan Medoxomil in bulk and tablet dosage form. The RP-HPLC method has shown adequate separation for Metoprolol Succinate and Olmesartan Medoxomil from its degradation products. The separation was achieved on a Phenomenex luna ODS C18 (250mm X 4.6mm i.d., 5μm particle size) with an isocratic mixture of acetonitrile: 50mM phosphate buffer pH 4.0 adjusted with glacial acetic acid in the ratio of 55:45 v/v. The mobile phase at a flow rate of 1.0ml/min, Injection volume 20μl and wavelength of detection was kept at 225nm. The retention time for Metoprolol Succinate and Olmesartan Medoxomil was 2.451±0.1min and 6.167±0.1min, respectively. The linearity of the proposed method was investigated in the range of 5-50μg/ml and 2-20μg/ml for Metoprolol Succinate and Olmesartan Medoxomil, respectively. Correlation coefficient was 0.999 and 0.9996 for Metoprolol Succinate and Olmesartan Medoxomil, respectively. The limit of detection was 0.2847μg/ml and 0.1251μg/ml for Metoprolol Succinate and Olmesartan Medoxomil, respectively and the limit of quantification was 0.8630μg/ml and 0.3793μg/ml for Metoprolol and Olmesartan, respectively. Proposed methods were validated as per ICH guidelines for linearity, accuracy, precision, specificity and robustness for estimation of Metoprolol Succinate and Olmesartan Medoxomil in commercially available tablet dosage form and results were found to be satisfactory. Thus the developed and validated stability indicating method can be used successfully for marketed formulations.

Keywords: metoprolol succinate, olmesartan medoxomil, RP-HPLC method, validation, ICH

Procedia PDF Downloads 316
603 Tracking of Linarin from the Ethyl Acetate Fraction of Melinjo (Gnetum gnemon L.) Seeds Using Preparative High Performance Liquid Chromatography

Authors: Asep Sukohar, Ramadhan Triyandi, Muhammad Iqbal, Sahidin, Suharyani

Abstract:

Introduction: Resveratrol is a class of bioactive chemicals found in melinjo, which has a wide range of biological actions. The purpose of this study is to determine the linarin content of the melinjo fraksi by using preparative-high-performance liquid chromatography (prep-HPLC). Method: Extraction used the soxhletation method with 96% ethanol solvent. Fractionation used ethyl acetate and ethanol in a ratio of 1:1. Tracing of linarin compound used prep-HPLC with a mobile phase ratio of distilled water: methanol (55: 45, v/v). The presence of linarin was detected using a wavelength of 215 nm. Fourier Transform Infrared (FTIR) was used to identify the functional groups of compound. Result: The retention time required to elute the ethyl acetate fraction was 2.601 minutes. Compound separation identification using Fourier Transform Infrared Spectroscopy - Quest Attenuated Total Reflectance (FTIR - QATR) has a similarity value range with standards from 0 to 1000. The elution results of the ethyl acetate fraction have similar values with the standard compounds linarin (668), resveratrol (578), and catechin (455). Conclusion: Tracing for active compound in the ethyl acetate fraction of Gnetum Gnemon L. using prep-HPLC showed a strong suspicion of the presence of linarin compound.

Keywords: Gnetum gnemon L., linarin, prep-HPLC, fraction ethyl acetate

Procedia PDF Downloads 120
602 HPLC-UV Screening of Legal (Caffeine and Yohimbine) and Illegal (Ephedrine and Sibutramine) Substances from Weight Loss Dietary Supplements for Athletes

Authors: Amelia Tero-Vescan, Camil-Eugen Vari, Laura Ciulea, Cristina Filip, Silvia Imre

Abstract:

A HPLC –UV method for the identification of ephedrine (EPH), sibutramine (SB), yohimbine (Y) and caffeine (CF) was developed. Separation was performed on a Kromasil 100-RP8, 150 mm x 4.6 mm, 5 mm column equipped with a precolumn Kromasil RP 8. Mobile phase was a gradient of 80-35 % sodium dihydrogen phosphate pH=5 with NH4OH and acetonitrile over 15 minutes time of analysis. Based on the responses of 113 athletes about dietary supplements (DS) consumed for "fat burning" and weight loss which have a legal status in Romania, 28 supplements have been selected and investigated for their content in CF, Y, legal substances, and SB, EPH (prohibited substances in DS). The method allows quantitative determination of the four substances in a short analysis time and with minimum cost. The presence of SB and EPH in the analyzed DS was not detected while the content in CF and Y considering the dosage recommended by the manufacturer does not affect the health of the consumers. DS labeling (plant extracts with CF and Y content) allows manufacturers to avoid declaring correct and exact amounts per pharmaceutical form (pure CF or equivalent and Y, respectively).

Keywords: dietary supplements, sibutramine, ephedrine, yohimbine, caffeine, HPLC

Procedia PDF Downloads 442
601 Simultaneous Determination of Cefazolin and Cefotaxime in Urine by HPLC

Authors: Rafika Bibi, Khaled Khaladi, Hind Mokran, Mohamed Salah Boukhechem

Abstract:

A high performance liquid chromatographic method with ultraviolet detection at 264nm was developed and validate for quantitative determination and separation of cefazolin and cefotaxime in urine, the mobile phase consisted of acetonitrile and phosphate buffer pH4,2(15 :85) (v/v) pumped through ODB 250× 4,6 mm, 5um column at a flow rate of 1ml/min, loop of 20ul. In this condition, the validation of this technique showed that it is linear in a range of 0,01 to 10ug/ml with a good correlation coefficient ( R>0,9997), retention time of cefotaxime, cefazolin was 9.0, 10.1 respectively, the statistical evaluation of the method was examined by means of within day (n=6) and day to day (n=5) and was found to be satisfactory with high accuracy and precision.

Keywords: cefazolin, cefotaxime, HPLC, bioscience, biochemistry, pharmaceutical

Procedia PDF Downloads 363
600 A Validated High-Performance Liquid Chromatography-UV Method for Determination of Malondialdehyde-Application to Study in Chronic Ciprofloxacin Treated Rats

Authors: Anil P. Dewani, Ravindra L. Bakal, Anil V. Chandewar

Abstract:

Present work demonstrates the applicability of high-performance liquid chromatography (HPLC) with UV detection for the determination of malondialdehyde as malondialdehyde-thiobarbituric acid complex (MDA-TBA) in-vivo in rats. The HPLC-UV method for MDA-TBA was achieved by isocratic mode on a reverse-phase C18 column (250mm×4.6mm) at a flow rate of 1.0mLmin−1 followed by UV detection at 278 nm. The chromatographic conditions were optimized by varying the concentration and pH followed by changes in percentage of organic phase optimal mobile phase consisted of mixture of water (0.2% Triethylamine pH adjusted to 2.3 by ortho-phosphoric acid) and acetonitrile in ratio (80:20 % v/v). The retention time of MDA-TBA complex was 3.7 min. The developed method was sensitive as limit of detection and quantification (LOD and LOQ) for MDA-TBA complex were (standard deviation and slope of calibration curve) 110 ng/ml and 363 ng/ml respectively. The method was linear for MDA spiked in plasma and subjected to derivatization at concentrations ranging from 100 to 1000 ng/ml. The precision of developed method measured in terms of relative standard deviations for intra-day and inter-day studies was 1.6–5.0% and 1.9–3.6% respectively. The HPLC method was applied for monitoring MDA levels in rats subjected to chronic treatment of ciprofloxacin (CFL) (5mg/kg/day) for 21 days. Results were compared by findings in control group rats. Mean peak areas of both study groups was subjected for statistical treatment to unpaired student t-test to find p-values. The p value was < 0.001 indicating significant results and suggesting increased MDA levels in rats subjected to chronic treatment of CFL of 21 days.

Keywords: MDA, TBA, ciprofloxacin, HPLC-UV

Procedia PDF Downloads 325
599 Factors Adversely Associated with Breastfeeding among Obese Mothers in Malaysia

Authors: Syahrul Bariah Abdul Hamid, Colin W. Binns, Jun Hui Chih

Abstract:

The total of obese mothers is growing throughout Asia. Breastfeeding provides the perfect nutrition for infants, by promoting a higher IQ and protecting against childhood and adult diseases. A prospective cohort study was carried out of mothers attending eight antenatal clinics run by the Ministry of Health in Selangor, Malaysia to document the prevalence of obesity and its relationship with breastfeeding outcomes. Mothers were enrolled during the antenatal period and followed up until 6 months postpartum to document breastfeeding outcomes. A total of 652 Malay mothers were recruited for the study a response rate of 93.1 %. The pre-pregnancy body mass index (BMI) of the mothers showed that 36.5% of the mothers were overweight or obese. There were a total of 78 obese mothers in the sample and 41 (52.6%) of these mothers were able to initiate breastfeeding within one hour of birth compared to 238/337 (70.6 %, χ² 9.35, p<0.001) of those with a normal BMI. At 6 months, 23.1 % of obese mothers were exclusively breastfeeding their infants, compared to 56.0 % of the normal BMI mothers. On the other hand, the rate of infant formula feeding was higher in the obese mothers by 53.8 % compared to 19.0 % among normal weight mothers, χ² 37.6, p<0.001). Further analysis suggested these factors were found to be positively associated with discontinued exclusive breastfeeding at 6 months among obese mothers; mothers whom delayed breastfeeding initiation, had health problems during pregnancy, caesarean delivery, reported had insufficient colostrum/milk and babies had sucking problems at or before 4 weeks. Besides that, mothers who perceived their biological mothers had preference towards formula feeding or were ambivalent about the feeding method and had biological mothers without experience in breastfeeding for more than 1 month also were more likely to discontinue exclusive breastfeeding at 6 months. These findings suggested that the greater the pre-pregnant BMI, the earlier the cessation of exclusive breastfeeding and they were also less likely to initiate breastfeeding and have less adequate milk supply. Future investigations of the effects of maternal obesity on breastfeeding outcomes should be conducted along with effective interventions to advance the care of obese women at reproductive age and their children.

Keywords: exclusive breastfeeding, body mass index (BMI), breastfeeding discontinuation, maternal obesity

Procedia PDF Downloads 195
598 Purification of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) from Fish Oil Using HPLC Method and Investigation of Their Antibacterial Effects on Some Pathogenic Bacteria

Authors: Yılmaz Uçar, Fatih Ozogul, Mustafa Durmuş, Yesim Ozogul, Ali Rıza Köşker, Esmeray Kuley Boğa, Deniz Ayas

Abstract:

The aim of this study was to purified eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), that are essential oils from trout oil, using high-performance liquid chromatography (HPLC) method, bioconverted EPA and DHA into bioconverted EPA (bEPA), bioconverted DHA (bDHA) extracts by P. aeruginosa PR3. Moreover, in vitro antibacterial activity of bEPA and bDHA was investigated using disc diffusion methods and minimum inhibitory concentration (MIC). EPA and DHA concentration of 11.1% and 15.9% in trout oil increased in 58.64% and 40.33% after HPLC optimisation, respectively. In this study, EPA and DHA enriched products were obtained which are to be used as valuable supplements for food and pharmaceutical purposes. The bioconverted EPA and DHA exhibited antibacterial activities against two Gram-positive bacteria (Listeria monocytogenes ATCC 7677 and Staphylococcus aureus ATCC 29213) and six Gram-negative bacteria (Pseudomonas aeruginosa ATCC 27853, Escherichia coli ATCC 25922, Klebsiella pneumoniae ATCC700603, Enterococcus faecalis ATCC 29212, Aeromonas hydrophila NCIMB 1135, and Salmonella Paratyphi A NCTC 13). Inhibition zones and MIC value of bEPA and bDHA against bacterial strains ranged from 7 to 12 mm and from 350 to 2350 μg/mL, respectively. Our results suggested that the crude extracts of bioconversion of EPA and DHA by P. aeruginosa PR3 can be considered as promising antimicrobials in improving food safety by controlling foodborne pathogens.

Keywords: High-Performance Liquid Chromatography (HPLC), docosahexaenoic acid, DHA, eicosapentaenoic acid, EPA, minimum inhibitory concentration, MIC, Pseudomonas aeruginosa PR3

Procedia PDF Downloads 501
597 Phytochemical Investigation of Berries of the Embelia schimperi Plant

Authors: Tariku Nefo Duke

Abstract:

Embelia is a genus of climbing shrubs in the family Myrsinaceae. Embelia schimperi is as important in traditional medicine as the other species in the genus. The plant has been much known as a local medicine for the treatment of tapeworms. In this project, extraction, phytochemical screening tests, isolation, and characterization of berries of the Embelia schimperi plant have been conducted. The chemical investigations of methanol and ethyl acetate (1:1) ratio extracts of the berries lead to the isolation of three new compounds. The compounds were identified to be alkaloids coded as AD, AN, and AG. Structural elucidations of the isolated compounds were accomplished using spectroscopic methods (IR, UV, ¹H NMR, ¹³C NMR, DEPT and 2D NMR, HPLC, and LC-MS). The alkaloid coded as (AN) has a wide MIC range of 6.31-25.46 mg/mL against all tested bacteria strains.

Keywords: Embelia schimper, HPLC, alkaloids, 2D NMR, MIC

Procedia PDF Downloads 99
596 Quantitative Analysis of (+)-Catechin and (-)-Epicatechin in Pentace burmanica Stem Bark by HPLC

Authors: Thidarat Duangyod, Chanida Palanuvej, Nijsiri Ruangrungsi

Abstract:

Pentace burmanica Kurz., belonging to the Malvaceae family, is commonly used for anti-diarrhea in Thai traditional medicine. A method for quantification of (+)-catechin and (-)-epicatechin in P. burmanica stem bark from 12 different Thailand markets by reverse-phase high performance liquid chromatography (HPLC) was investigated and validated. The analysis was performed by a Shimadzu DGU-20A3 HPLC equipped with a Shimadzu SPD-M20A photo diode array detector. The separation was accomplished with an Inersil ODS-3 column (5 µm x 4.6 x 250 mm) using 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) as mobile phase at the flow rate of 1 ml/min. The isocratic was set at 20% B for 15 min and the column temperature was maintained at 40 ºC. The detection was at the wavelength of 280 nm. Both (+)-catechin and (-)-epicatechin existed in the ethanolic extract of P. burmanica stem bark. The content of (-)-epicatechin was found as 59.74 ± 1.69 µg/mg of crude extract. In contrast, the quantitation of (+)-catechin content was omitted because of its small amount. The method was linear over a range of 5-200 µg/ml with good coefficients (r2 > 0.99) for (+)-catechin and (-)-epicatechin. Limit of detection values were found to be 4.80 µg/ml for (+)-catechin and 5.14 µg/ml for (-)-epicatechin. Limit of quantitation of (+)-catechin and (-)-epicatechin were of 14.54 µg/ml and 15.57 µg/ml respectively. Good repeatability and intermediate precision (%RSD < 3) were found in this study. The average recoveries of both (+)-catechin and (-)-epicatechin were obtained with good recovery in the range of 91.11 – 97.02% and 88.53 – 93.78%, respectively, with the %RSD less than 2. The peak purity indices of catechins were more than 0.99. The results suggested that HPLC method proved to be precise and accurate and the method can be conveniently used for (+)-catechin and (-)-epicatechin determination in ethanolic extract of P. burmanica stem bark. Moreover, the stem bark of P. burmanica was found to be a rich source of (-)-epicatechin.

Keywords: pentace burmanica, (+)-catechin, (-)-epicatechin, high performance liquid chromatography

Procedia PDF Downloads 455
595 Determination of Aflatoxins in Edible-Medicinal Plant Samples by HPLC with Fluorescence Detector and KOBRA-Cell

Authors: Isil Gazioglu, Abdulselam Ertas

Abstract:

Aflatoxins (AFs) are secondary toxic metabolites of Aspergillus flavus and A. parasiticus. AFs can be absorbed through the skin. Potent carcinogens like AFs should be completely absent from cosmetics, this can be achieved by careful quality control of the raw plant materials. Regulatory limits for aflatoxins have been established in many countries, and reliable testing methodology is needed to implement and enforce the regulatory limits. In this study, ten medicinal plant samples (Bundelia tournefortti, Capsella bursa-pastoris, Carduus tenuiflorus, Cardaria draba, Malva neglecta, Malvella sharardiana, Melissa officinalis, Sideritis libanotica, Stakys thirkei, Thymus nummularius) were investigated for aflatoxin (AF) contaminations by employing an HPLC assay for the determination of AFB1, B2, G1 and G2. The samples were extracted with 70% (v/v) methanol in water before further cleaned up with an immunoaffinity column and followed by the detection of AFs by using an electrochemically post-column derivatization with Kobra-Cell and fluorescence detector. The extraction procedure was optimized in order to obtain the best recovery. The method was successfully carried out with all medicinal plant samples. The results revealed that five (50%) of samples were contaminated with AFs. The association between particular samples and the AF contaminated could not be determined due to the low frequency of positive samples.

Keywords: aflatoxin B1, HPLC-FLD, KOBRA-Cell, mycotoxin

Procedia PDF Downloads 606
594 The Comparison and Optimization of the Analytic Method for Canthaxanthin, Food Colorants

Authors: Hee-Jae Suh, Kyung-Su Kim, Min-Ji Kim, Yeon-Seong Jeong, Ok-Hwan Lee, Jae-Wook Shin, Hyang-Sook Chun, Chan Lee

Abstract:

Canthaxanthin is keto-carotenoid produced from beta-carotene and it has been approved to be used in many countries as a food coloring agent. Canthaxanthin has been analyzed using High Performance Liquid Chromatography (HPLC) system with various ways of pretreatment methods. Four official methods for verification of canthaxanthin at FSA (UK), AOAC (US), EFSA (EU) and MHLW (Japan) were compared to improve its analytical and the pretreatment method. The Linearity, the limit of detection (LOD), the limit of quantification (LOQ), the accuracy, the precision and the recovery ratio were determined from each method with modification in pretreatment method. All HPLC methods exhibited correlation coefficients of calibration curves for canthaxanthin as 0.9999. The analysis methods from FSA, AOAC, and MLHW showed the LOD of 0.395 ppm, 0.105 ppm, and 0.084 ppm, and the LOQ of 1.196 ppm, 0.318 ppm, 0.254 ppm, respectively. Among tested methods, HPLC method of MHLW with modification in pretreatments was finally selected for the analysis of canthaxanthin in lab, because it exhibited the resolution factor of 4.0 and the selectivity of 1.30. This analysis method showed a correlation coefficients value of 0.9999 and the lowest LOD and LOQ. Furthermore, the precision ratio was lower than 1 and the accuracy was almost 100%. The method presented the recovery ratio of 90-110% with modification in pretreatment method. The cross-validation of coefficient variation was 5 or less among tested three institutions in Korea.

Keywords: analytic method, canthaxanthin, food colorants, pretreatment method

Procedia PDF Downloads 683
593 Development and Validation of a HPLC Method for 6-Gingerol and 6-Shogaol in Joint Pain Relief Gel Containing Ginger (Zingiber officinale)

Authors: Tanwarat Kajsongkram, Saowalux Rotamporn, Sirinat Limbunruang, Sirinan Thubthimthed.

Abstract:

High-Performance Liquid Chromatography (HPLC) method was developed and validated for simultaneous estimation of 6-Gingerol(6G) and 6-Shogaol(6S) in joint pain relief gel containing ginger extract. The chromatographic separation was achieved by using C18 column, 150 x 4.6mm i.d., 5μ Luna, mobile phase containing acetonitrile and water (gradient elution). The flow rate was 1.0 ml/min and the absorbance was monitored at 282 nm. The proposed method was validated in terms of the analytical parameters such as specificity, accuracy, precision, linearity, range, limit of detection (LOD), limit of quantification (LOQ), and determined based on the International Conference on Harmonization (ICH) guidelines. The linearity ranges of 6G and 6S were obtained over 20-60 and 6-18 µg/ml respectively. Good linearity was observed over the above-mentioned range with linear regression equation Y= 11016x- 23778 for 6G and Y = 19276x-19604 for 6S (x is concentration of analytes in μg/ml and Y is peak area). The value of correlation coefficient was found to be 0.9994 for both markers. The limit of detection (LOD) and limit of quantification (LOQ) for 6G were 0.8567 and 2.8555 µg/ml and for 6S were 0.3672 and 1.2238 µg/ml respectively. The recovery range for 6G and 6S were found to be 91.57 to 102.36 % and 84.73 to 92.85 % for all three spiked levels. The RSD values from repeated extractions for 6G and 6S were 3.43 and 3.09% respectively. The validation of developed method on precision, accuracy, specificity, linearity, and range were also performed with well-accepted results.

Keywords: ginger, 6-gingerol, HPLC, 6-shogaol

Procedia PDF Downloads 445
592 Exclusive Value Adding by iCenter Analytics on Transient Condition

Authors: Zhu Weimin, Allegorico Carmine, Ruggiero Gionata

Abstract:

During decades of Baker Hughes (BH) iCenter experience, it is demonstrated that in addition to conventional insights on equipment steady operation conditions, insights on transient conditions can add significant and exclusive value for anomaly detection, downtime saving, and predictive maintenance. Our work shows examples from the BH iCenter experience to introduce the advantages and features of using transient condition analytics: (i) Operation under critical engine conditions: e.g., high level or high change rate of temperature, pressure, flow, vibration, etc., that would not be reachable in normal operation, (ii) Management of dedicated sub-systems or components, many of which are often bottlenecks for reliability and maintenance, (iii) Indirect detection of anomalies in the absence of instrumentation, (iv) Repetitive sequences: if data is properly processed, the engineering features of transients provide not only anomaly detection but also problem characterization and prognostic indicators for predictive maintenance, (v) Engine variables accounting for fatigue analysis. iCenter has been developing and deploying a series of analytics based on transient conditions. They are contributing to exclusive value adding in the following areas: (i) Reliability improvement, (ii) Startup reliability improvement, (iii) Predictive maintenance, (iv) Repair/overhaul cost down. Illustrative examples for each of the above areas are presented in our study, focusing on challenges and adopted techniques ranging from purely statistical approaches to the implementation of machine learning algorithms. The obtained results demonstrate how the value is obtained using transient condition analytics in the BH iCenter experience.

Keywords: analytics, diagnostics, monitoring, turbomachinery

Procedia PDF Downloads 74
591 Child Feeding Practices of Mothers (Childbearing) and Exploration of Their Household Food Insecurity in a Coastal Region of Bangladesh

Authors: Md Abdullah Al Mamun

Abstract:

Background: The current situation of Ensuring WHO recommended feeding practices for infant and young children which is becoming a challenge nowadays in many developing countries, especially in areas where household food security is at risk. Because many households of the developing countries often encounter severe food insecurity hence provision of adequate child nutrition is threatened. Aim: The study aimed to assess the child feeding practices of 0-24 months childbearing mothers and explore their household food insecurity in a coastal region of Bangladesh. Methods: This study was conducted in Suborno Char (one of the coastal suburbs in Noakhali District in Bangladesh) from October 2019 to April 2020. A total of 400 mothers were selected with their children of 0-24 months following a cross sectional study sampling procedure of the population. Data were collected through a standard questionnaire and analyzed using statistical tests in SPSS version 20.0.0. Results: The frequency of exclusive breastfeeding, timely initiation of complementary feeding, and giving foods from four food groups to the children were 53.5%, 75.5%, and 22.2%, respectively. Mother's level of education showed a strong association with the child feeding practices of the mothers. Mothers of severely food insecure households showed lower odds in exclusive breastfeeding practice (COR 0.233 at 95% CI 0.083, 0.655; and AOR 0.478 at 95% CI 0.133, 1.713) than mothers of food secured households. Similar results have also been found in case of timely initiation of complementary feeding and minimum dietary diversity of the children.

Keywords: household food insecurity, exclusive breastfeeding, complementary feeding, maternal education, mothers age, household income

Procedia PDF Downloads 159
590 Pharmacokinetic Study of Clarithromycin in Human Female of Pakistani Population

Authors: Atifa Mushtaq, Tanweer Khaliq, Hafiz Alam Sher, Asia Farid, Anila Kanwal, Maliha Sarfraz

Abstract:

The study was designed to assess the various pharmacokinetic parameters of a commercially available clarithromycin Tablet (Klaricid® 250 mg Abbot, Pakistan) in plasma sample of healthy adult female volunteers by applying a rapid, sensitive and accurate HPLC-UV analytical method. The human plasma samples were evaluated by using an isocratic High Performance Liquid Chromatography (HPLC) system of Sykam consisted of a pump with a column C18 column (250×4.6mn, 5µm) UV-detector. The mobile phase comprises of potassium dihydrogen phosphate (50 mM, pH 6.8, contained 0.7% triethylamine), methanol and acetonitrile (30:25:45, v/v/v) was delivered with injection volume of 20µL at flow rate of 1 mL/min. The detection was performed at λmax 275 nm. By applying this method, important pharmacokinetic parameters Cmax, Tmax, Area under curve (AUC), half-life (t1/2), , Volume of distribution (Vd) and Clearance (Cl) were measured. The parameters of pharmacokinetics of clarithromycin were calculated by software (APO) pharmacological analysis. Maximum plasma concentrations Cmax 2.78 ±0.33 µg/ml, time to reach maximum concentration tmax 2.82 ± 0.11 h and Area under curve AUC was 20.14 h.µg/ml. The mean ± SD values obtained for the pharmacokinetic parameters showed a significant difference in pharmacokinetic parameters observed in previous literature which emphasizes the need for dose adjustment of clarithromycin in Pakistani population.

Keywords: Pharmacokinetc, Clarothromycin, HPLC, Pakistan

Procedia PDF Downloads 108
589 ANFIS Based Technique to Estimate Remnant Life of Power Transformer by Predicting Furan Contents

Authors: Priyesh Kumar Pandey, Zakir Husain, R. K. Jarial

Abstract:

Condition monitoring and diagnostic is important for testing of power transformer in order to estimate the remnant life. Concentration of furan content in transformer oil can be a promising indirect measurement of the aging of transformer insulation. The oil gets contaminated mainly due to ageing. The present paper introduces adaptive neuro fuzzy technique to correlate furanic compounds obtained by high performance liquid chromatography (HPLC) test and remnant life of the power transformer. The results are obtained by conducting HPLC test at TIFAC-CORE lab, NIT Hamirpur on thirteen power transformer oil samples taken from Himachal State Electricity Board, India.

Keywords: adaptive neuro fuzzy technique, furan compounds, remnant life, transformer oil

Procedia PDF Downloads 464
588 Estimation of Enantioresolution of Multiple Stereogenic Drugs Using Mobilized and/or Immobilized Polysaccharide-Based HPLC Chiral Stationary Phases

Authors: Mohamed Hefnawy, Abdulrahman Al-Majed, Aymen Al-Suwailem

Abstract:

Enantioseparation of drugs with multiple stereogenic centers is challenging. This study objectives to evaluate the efficiency of different mobilized and/or immobilized polysaccharide-based chiral stationary phases to separate enantiomers of some drugs containing multiple stereogenic centers namely indenolol, nadolol, labetalol. The critical mobile phase variables (composition of organic solvents, acid/base ratios) were carefully studied to compare the retention time and elution order of all isomers. Different chromatographic parameters such as capacity factor (k), selectivity (α) and resolution (Rs) were calculated. Experimental conditions and the possible chiral recognition mechanisms have been discussed.

Keywords: HPLC, polysaccharide columns, enantio-resolution, indenolol, nadolol, labetalol

Procedia PDF Downloads 454
587 Exclusive Breast Feeding Practices in Bangladesh

Authors: Md. Ashikur Rahman

Abstract:

Optimal breastfeeding practice is essential to reducing childhood morbidity and mortality and helps to achieve Millennium Development Goal (MDG). A cross-sectional study was conducted in a rural area in Dhaka district to explore the barrier to optimal breastfeeding practices. The population of this study constitutes all nursing mothers having children aged 0-6 months, and they were selected purposively. The study adopted a structured and in-depth interview procedure consisting of open and closed-ended questions. Four hundred rural nursing mothers constituted the sample of the structured interview, while 15 were involved in the in-depth interview. Among the respondent's majority (67%) were in the age group 17-25 years, with a mean age of 24.44 years. Most (39.5%) of the mothers were housewives with a secondary level of education (46.5%). About 32% of mothers started breastfeeding within one hour after birth. But delayed initiation was reported in 31.5% of mothers, whereas 36.8% of mothers forgot the exact time of initiation of breastfeeding. The main reason not to practice colostrum was mothers tried to breastfeed, but there was no milk, stated 13.8% of mothers. In addition, about one-third (34.3%) of the respondents practiced pre-lacteal feeding, and among them, 12.8% introduced sugar with water. Reasons given by the mothers for bottle-feeding was that baby was not satisfied with breast milk only; 22.0% of mothers indicated this cause. The main influence to take formula milk by their mother and mothers-in-law was stated by 18.8% of mothers. Some mothers stated that major constraints to EBF were the perception of not having enough milk (25.5 %) and babies crying seems to be hungry (8.8%). One-third of the mothers (31.5%) felt uncomfortable during breastfeeding. Access to antenatal and postnatal counseling in the study area also was a key obstacle to optimal breastfeeding practices. In a qualitative survey, some mothers believed that there was no difference between breast milk and formula milk. Colostrum feeding, pre-lacteal feeding, early initiation of breastfeeding, and exclusive breastfeeding were strongly associated with family type, family member, birth order, religion, husbands' occupation, delivery attendants and delivery type, postnatal care, and health care facilities. To reduce the barriers to the successful practice of exclusive breastfeeding, there is a need for a grass-roots approach to educating and counseling nursing mothers with identifying factors influencing or discouraging the optimal practice.

Keywords: exclusive, breast feeding, practices, Bangladesh

Procedia PDF Downloads 95
586 An Investigation of How Salad Rocket May Provide Its Own Defence Against Spoilage Bacteria

Authors: Huda Aldossari

Abstract:

Members of the Brassicaceae family, such as rocket species, have high concentrations of glucosinolates (GLSs). GSLs and isothiocyanates (ITCs), the product of GLSs hydrolysis, are the most influential compounds that affect flavour in rocket species. Aside from their contribution to the flavour, GSLs and ITCs are of particular interest due to their potential ability to inhibit the growth of human pathogenic bacteria such as E. coli O157. Quantitative and qualitative analysis of glucosinolate compounds in rocket extracts was obtained by Liquid Chromatography-Mass Spectrometry (LC–MS).Each individual component of non-volatile GLSs and ITCs was isolated by High-Performance Liquid Chromatography (HPLC) fractionation. The identity and purity of each fraction were confirmed using Ultra High-Performance Liquid Chromatography (UPLC). The separation of glucosinolates in the complex rocket extractions was performed by optimizing a HPLC fractionation method through changing the mobile phase composition, solvent gradient, and the flow rate. As a result, six glucosinolates compounds (Glucosativin, 4-Methoxyglucobrassicin, Glucotropaeolin GTP, Glucoiberin GIB, Diglucothiobenin, and Sinigrin) have been isolated, identified and quantified in the complex samples. This step aims to evaluate the antibacterial activity of glucosinolates and their enzymatic hydrolysis against bacterial growth of E.coli k12. Therefore, fractions from this study will be used to determine the most active compounds by investigating the efficacy of each component of GLSs and ITCs at inhibiting bacterial growth.

Keywords: rocket, glucosinolates, E.coli k12., HPLC fractionatio

Procedia PDF Downloads 98
585 Use RP-HPLC To Investigate Factors Influencing Sorghum Protein Extraction

Authors: Khaled Khaladi, Rafika Bibi, Hind Mokrane, Boubekeur Nadjemi

Abstract:

Sorghum (Sorghum bicolor (L.) Moench) is an important cereal crop grown in the semi-arid tropics of Africa and Asia due to its drought tolerance. Sorghum grain has protein content varying from 6 to 18%, with an average of 11%, Sorghum proteins can be broadly classified into prolamin and non-prolamin proteins. Kafirins, the major storage proteins, are classified as prolamins, and as such, they contain high levels of proline and glutamine and are soluble in non-polar solvents such as aqueous alcohols. Kafirins account for 77 to 82% of the protein in the endosperm, whereas non-prolamin proteins (namely, albumins, globulins, and glutelins) make up about 30% of the proteins. To optimize the extraction of sorghum proteins, several variables were examined: detergent type and concentration, reducing agent type and concentration, and buffer pH and concentration. Samples were quantified and characterized by RP-HPLC.

Keywords: sorghum, protein extraction, detergent, food science

Procedia PDF Downloads 322
584 Evaluation of Polyphenolics Compounds in Cold Brewed Indian Tea

Authors: Chandrima Das, Sirshendu Chatterjee

Abstract:

Tea (Camellia sinensis) is known as nature's low calorie wonder drink. Since ancient times hot consumptions of tea is very much popular. We have observed that many heat sensitive secondary metabolites which get destroyed on heating, moreover by people, who are permanently live at higher altitude or the members of high altitude expedition team, are deprived of various tea brewing facilities like electricity, fuel, etc. and the hence cold decoction of tea might be a good alternative. In this backdrop present study aims at the analysis of antioxidants like polyphenols, flavonoids and free radical scavenging activity as well as the l-theanine concentration of different types of cold brewed teas like black, green, white and oolong and compared with its hot decoction. Further, we also analysed in details about the bioactive components by using HPLC followed by green synthesis of nanoparticles. The study highlighted that the difference between the concentration of antioxidant in cold and hot brewed tea is insignificant and hence intake of cold decoction will be beneficial to health.

Keywords: antioxidants, flavanoid, polyphenols, HPLC, nanoparticles

Procedia PDF Downloads 307
583 Separation of Fexofenadine Enantiomers Using Beta Cyclodextrin as Chiral Counter Ion in Mobile Phase

Authors: R. Fegas, S. Zerkout, S. Taberkokt, M. Righezza

Abstract:

The present work demonstrate the potential of Betacyclodextrine (BCD) for the chiral analysis of a drug .Various separation mechanisms were applied and several parameters affecting the separation were studied, including the type and concentration of chiral selector, and pH of buffer. A simple and sensitive high-performance liquid chromatography (HPLC) method was developed as an assay for fexofenadine enantiomers in pharmaceutical preparation. Fexofenadine enantiomers were separated using a mobile phase of 0.25mM NaH2PO4–acetonitrile (65:35, v/v) – Betacyclodextrine on achiral phenyl-urea column at a flow rate of 1ml/min and measurement at 220nm. The chiral mechanism of separation was mainly based on specific interaction between the solute and the stationary phase. The retention was directly controlled by mobile phase composition but not the selectivity which results of the two mechanisms, electrostatic interactions and partition mechanism.

Keywords: fexofenadine enantiomer, HPLC, achiral phenyl-urea column

Procedia PDF Downloads 458
582 Development of Stability Indicating Method and Characterization of Degradation Impurity of Nirmaltrelvir in Its Self-Emulsifying Drug Delivery System

Authors: Ravi Patel, Ravisinh Solanki, Dignesh Khunt

Abstract:

A stability-indicating reverse phase high performance liquid chromatography (RP-HPLC) method was developed and validated for estimating Nirmatrelvir in its self-emulsifying drug delivery system (SEDDS). The separation of Nirmatrelvir and its degradation products was accomplished by employing an Agilent Zorbax Eclipse plus C18 (250 mm x 4.6 mm, 5 µm) column, through which the mobile phase 5 mM phosphate buffer (pH 4.0) as mobile phase A and Acetonitrile as mobile phase B in a ratio of (40:60 % v/v) was pumped at a flow rate of 1.0 mL/min, through the HPLC system. Chromatographic separation and elution were monitored by a photo-diode array detector at 210 nm. Stress studies have been employed to evaluate this method's ability to indicate stability. Nirmatrelvir was exposed to several stress conditions, such as acid, alkali, oxidative, photolytic, and thermal degradations. Significant degradation was observed during acid and alkali hydrolysis, and the resulting degradation product was successfully separated from the Nirmatrelvir peak, preventing any interference. Furthermore, the primary degradant produced under alkali degradation conditions was identified using UPLC-ESI-TQ-MS/MS. The method was validated in accordance with the International Council on Harmonization (ICH) and found to be selective, precise, accurate, linear, and robust. The apparent permeability of Nirmatrelvir SEDDS was 4.20 ± 0.21×10-6 cm/sec, and the average proportion of free drug recovered was 0.5%. The method developed in this study was feasible and accurate for routine quality control evaluation of Nirmatrelvir SEDDS.

Keywords: Nirmatrelvir, SEDDS, degradation study, HPLC, LC-MS/MS

Procedia PDF Downloads 20
581 Nematicidal Activity of the Cell Extract from Penicillium Sp EU0013 and Its Metabolite Profile Using High Performance Liquid Chromatograpy

Authors: Zafar Iqbal, Sana Irshad Khan

Abstract:

Organic extract from newly isolated plant growth promoting fungus (PGPF) Penicillium sp EU0013 was subjected to bioassays including anti fungal (disc diffusion) cytotoxicity (brine shrimp lethality), herbicidal (Lemna minor) and nematicidal activities. Metabolite profile of the extract was also assessed using HPLC analysis with the aim to identify bioactive natural products in the extract as new drug candidate(s). The extract showed anti fungal potential against tested fungal pathogens. Growth of the Wilt pathogen Fusarium oxyosproum was inhibited up to 63% when compared to negative reference. Activity against brine shrimps was weak and mortality up to 10% was observed at concentration of 200 µg. mL-1. The extract exhibited no toxicity against Lemna minor frond at 200 µg. mL-1. Nematicidal activity was observed very potent against root knot nematode and LC50 value was calculated as 52.5 ug. mL-1 using probit analysis. Methodically assessment of metabolites profile by HPLC showed the presence of kojic acid (Rt 1.4 min) and aflatoxin B1 (Rt 5.9 min) in the mycellial extract as compared with standards. The major unidentified metabolite was eluted at Rt 8.6 along with other minor peaks. The observed high toxicity against root knot nematode was attributed to the unidentified compounds that make fungal extract worthy of further exploration for isolation and structural characterization studies for development of future commercial nematicidal compound(s).

Keywords: penicillium, nematicidal activity, metabolites, HPLC

Procedia PDF Downloads 447
580 Determination of the Stability of Haloperidol Tablets and Phenytoin Capsules Stored in the Inpatient Dispensary System (Swisslog) by the Respective HPLC and Raman Spectroscopy Assay

Authors: Carol Yue-En Ong, Angelina Hui-Min Tan, Quan Liu, Paul Chi-Lui Ho

Abstract:

A public general hospital in Singapore has recently implemented an automated unit-dose machine in their inpatient dispensary, Swisslog, with the objective of reducing human error and improving patient safety. However, a concern in stability arises as tablets are removed from their original packaging (bottled loose tablets/capsules) and are repackaged into individual, clear plastic wrappers as unit doses in the system. Drugs that are light-sensitive and hygroscopic would be more susceptible to degradation as the wrapper does not offer full protection. Hence, this study was carried out to study the stability of haloperidol tablets and phenytoin capsules that are light-sensitive and hygroscopic respectively. Validated HPLC-UV assays were first established for quantification of these two compounds. The medications involved were put in the Swisslog and sampled every week for one month. The collected data was analysed and showed no degradation over time. This study also explored an alternative approach for drug stability determination-Raman spectroscopy. The advantage of Raman spectroscopy is its high time efficiency and non-destructive nature. The results suggest that drug degradation can indeed be detected using Raman microscopy, but further research is needed to establish this approach for quantification or qualification of compounds. NanoRam®, a portable Raman spectrocope was also used alongside Raman microscopy but was unsuccessful in detecting degradation in this study.

Keywords: drug stability, haloperidol, HPLC, phenytoin, raman spectroscopy, Swisslog

Procedia PDF Downloads 350
579 Development and Validation of High-Performance Liquid Chromatography Method for the Determination and Pharmacokinetic Study of Linagliptin in Rat Plasma

Authors: Hoda Mahgoub, Abeer Hanafy

Abstract:

Linagliptin (LNG) belongs to dipeptidyl-peptidase-4 (DPP-4) inhibitor class. DPP-4 inhibitors represent a new therapeutic approach for the treatment of type 2 diabetes in adults. The aim of this work was to develop and validate an accurate and reproducible HPLC method for the determination of LNG with high sensitivity in rat plasma. The method involved separation of both LNG and pindolol (internal standard) at ambient temperature on a Zorbax Eclipse XDB C18 column and a mobile phase composed of 75% methanol: 25% formic acid 0.1% pH 4.1 at a flow rate of 1.0 mL.min-1. UV detection was performed at 254nm. The method was validated in compliance with ICH guidelines and found to be linear in the range of 5–1000ng.mL-1. The limit of quantification (LOQ) was found to be 5ng.mL-1 based on 100µL of plasma. The variations for intra- and inter-assay precision were less than 10%, and the accuracy values were ranged between 93.3% and 102.5%. The extraction recovery (R%) was more than 83%. The method involved a single extraction step of a very small plasma volume (100µL). The assay was successfully applied to an in-vivo pharmacokinetic study of LNG in rats that were administered a single oral dose of 10mg.kg-1 LNG. The maximum concentration (Cmax) was found to be 927.5 ± 23.9ng.mL-1. The area under the plasma concentration-time curve (AUC0-72) was 18285.02 ± 605.76h.ng.mL-1. In conclusion, the good accuracy and low LOQ of the bioanalytical HPLC method were suitable for monitoring the full pharmacokinetic profile of LNG in rats. The main advantages of the method were the sensitivity, small sample volume, single-step extraction procedure and the short time of analysis.

Keywords: HPLC, linagliptin, pharmacokinetic study, rat plasma

Procedia PDF Downloads 241
578 Stability Indicating RP – HPLC Method Development, Validation and Kinetic Study for Amiloride Hydrochloride and Furosemide in Pharmaceutical Dosage Form

Authors: Jignasha Derasari, Patel Krishna M, Modi Jignasa G.

Abstract:

Chemical stability of pharmaceutical molecules is a matter of great concern as it affects the safety and efficacy of the drug product.Stability testing data provides the basis to understand how the quality of a drug substance and drug product changes with time under the influence of various environmental factors. Besides this, it also helps in selecting proper formulation and package as well as providing proper storage conditions and shelf life, which is essential for regulatory documentation. The ICH guideline states that stress testing is intended to identify the likely degradation products which further help in determination of the intrinsic stability of the molecule and establishing degradation pathways, and to validate the stability indicating procedures. A simple, accurate and precise stability indicating RP- HPLC method was developed and validated for simultaneous estimation of Amiloride Hydrochloride and Furosemide in tablet dosage form. Separation was achieved on an Phenomenexluna ODS C18 (250 mm × 4.6 mm i.d., 5 µm particle size) by using a mobile phase consisting of Ortho phosphoric acid: Acetonitrile (50:50 %v/v) at a flow rate of 1.0 ml/min (pH 3.5 adjusted with 0.1 % TEA in Water) isocratic pump mode, Injection volume 20 µl and wavelength of detection was kept at 283 nm. Retention time for Amiloride Hydrochloride and Furosemide was 1.810 min and 4.269 min respectively. Linearity of the proposed method was obtained in the range of 40-60 µg/ml and 320-480 µg/ml and Correlation coefficient was 0.999 and 0.998 for Amiloride hydrochloride and Furosemide, respectively. Forced degradation study was carried out on combined dosage form with various stress conditions like hydrolysis (acid and base hydrolysis), oxidative and thermal conditions as per ICH guideline Q2 (R1). The RP- HPLC method has shown an adequate separation for Amiloride hydrochloride and Furosemide from its degradation products. Proposed method was validated as per ICH guidelines for specificity, linearity, accuracy; precision and robustness for estimation of Amiloride hydrochloride and Furosemide in commercially available tablet dosage form and results were found to be satisfactory and significant. The developed and validated stability indicating RP-HPLC method can be used successfully for marketed formulations. Forced degradation studies help in generating degradants in much shorter span of time, mostly a few weeks can be used to develop the stability indicating method which can be applied later for the analysis of samples generated from accelerated and long term stability studies. Further, kinetic study was also performed for different forced degradation parameters of the same combination, which help in determining order of reaction.

Keywords: amiloride hydrochloride, furosemide, kinetic study, stability indicating RP-HPLC method validation

Procedia PDF Downloads 465
577 Comprehensive Validation of High-Performance Liquid Chromatography-Diode Array Detection (HPLC-DAD) for Quantitative Assessment of Caffeic Acid in Phenolic Extracts from Olive Mill Wastewater

Authors: Layla El Gaini, Majdouline Belaqziz, Meriem Outaki, Mariam Minhaj

Abstract:

In this study, it introduce and validate a high-performance liquid chromatography method with diode-array detection (HPLC-DAD) specifically designed for the accurate quantification of caffeic acid in phenolic extracts obtained from olive mill wastewater. The separation process of caffeic acid was effectively achieved through the use of an Acclaim Polar Advantage column (5µm, 250x4.6mm). A meticulous multi-step gradient mobile phase was employed, comprising water acidified with phosphoric acid (pH 2.3) and acetonitrile, to ensure optimal separation. The diode-array detection was adeptly conducted within the UV–VIS spectrum, spanning a range of 200–800 nm, which facilitated precise analytical results. The method underwent comprehensive validation, addressing several essential analytical parameters, including specificity, repeatability, linearity, as well as the limits of detection and quantification, alongside measurement uncertainty. The generated linear standard curves displayed high correlation coefficients, underscoring the method's efficacy and consistency. This validated approach is not only robust but also demonstrates exceptional reliability for the focused analysis of caffeic acid within the intricate matrices of wastewater, thus offering significant potential for applications in environmental and analytical chemistry.

Keywords: high-performance liquid chromatography (HPLC-DAD), caffeic acid analysis, olive mill wastewater phenolics, analytical method validation

Procedia PDF Downloads 72