Search results for: discharge measurement
3029 Measurement of Greenhouse Gas Emissions from Sugarcane Plantation Soil in Thailand
Authors: Wilaiwan Sornpoon, Sébastien Bonnet, Savitri Garivait
Abstract:
Continuous measurements of greenhouse gases (GHGs) emitted from soils are required to understand diurnal and seasonal variations in soil emissions and related mechanism. This understanding plays an important role in appropriate quantification and assessment of the overall change in soil carbon flow and budget. This study proposes to monitor GHGs emissions from soil under sugarcane cultivation in Thailand. The measurements were conducted over 379 days. The results showed that the total net amount of GHGs emitted from sugarcane plantation soil amounts to 36 Mg CO2eq ha-1. Carbon dioxide (CO2) and nitrous oxide (N2O) were found to be the main contributors to the emissions. For methane (CH4), the net emission was found to be almost zero. The measurement results also confirmed that soil moisture content and GHGs emissions are positively correlated.Keywords: soil, GHG emission, sugarcane, agriculture, Thailand
Procedia PDF Downloads 4323028 Automatic Registration of Rail Profile Based Local Maximum Curvature Entropy
Authors: Hao Wang, Shengchun Wang, Weidong Wang
Abstract:
On the influence of train vibration and environmental noise on the measurement of track wear, we proposed a method for automatic extraction of circular arc on the inner or outer side of the rail waist and achieved the high-precision registration of rail profile. Firstly, a polynomial fitting method based on truncated residual histogram was proposed to find the optimal fitting curve of the profile and reduce the influence of noise on profile curve fitting. Then, based on the curvature distribution characteristics of the fitting curve, the interval search algorithm based on dynamic window’s maximum curvature entropy was proposed to realize the automatic segmentation of small circular arc. At last, we fit two circle centers as matching reference points based on small circular arcs on both sides and realized the alignment from the measured profile to the standard designed profile. The static experimental results show that the mean and standard deviation of the method are controlled within 0.01mm with small measurement errors and high repeatability. The dynamic test also verified the repeatability of the method in the train-running environment, and the dynamic measurement deviation of rail wear is within 0.2mm with high repeatability.Keywords: curvature entropy, profile registration, rail wear, structured light, train-running
Procedia PDF Downloads 2603027 Load Characteristics of Improved Howland Current Pump for Bio-Impedance Measurement
Authors: Zhao Weijie, Lin Xinjian, Liu Xiaojuan, Li Lihua
Abstract:
The Howland current pump is widely used in bio-impedance measurement. Much attention has been focused on the output impedance of the Howland circuit. Here we focus on the maximum load of the Howland source and discuss the relationship between the circuit parameters at maximum load. We conclude that the signal input terminal of the feedback resistor should be as large as possible, but that the current-limiting resistor should be smaller. The op-amp saturation voltage should also be high. The bandwidth of the circuit is proportional to the bandwidth of the op-amp. The Howland current pump was simulated using multisim12. When the AD8066AR was selected as the op-amp, the maximum load was 11.5 kΩ, and the Howland current pump had a stable output ipp to 2mAp up to 200 kHz. However, with an OPA847 op-amp and a load of 6.3 kΩ, the output current was also stable, and the frequency was as high as 3 MHz.Keywords: bio-impedance, improved Howland current pump, load characteristics, bioengineering
Procedia PDF Downloads 5133026 Water Quality Trading with Equitable Total Maximum Daily Loads
Authors: S. Jamshidi, E. Feizi Ashtiani, M. Ardestani, A. Feizi Ashtiani
Abstract:
Waste load allocation (WLA) strategies usually intend to find economical policies for water resource management. Water quality trading (WQT) is an approach that uses discharge permit market to reduce total environmental protection costs. This primarily requires assigning discharge limits known as total maximum daily loads (TMDLs). These are determined by monitoring organizations with respect to the receiving water quality and remediation capabilities. The purpose of this study is to compare two approaches of TMDL assignment for WQT policy in small catchment area of Haraz River, in north of Iran. At first, TMDLs are assigned uniformly for the whole point sources to keep the concentrations of BOD and dissolved oxygen (DO) at the standard level at checkpoint (terminus point). This was simply simulated and controlled by Qual2kw software. In the second scenario, TMDLs are assigned using multi objective particle swarm optimization (MOPSO) method in which the environmental violation at river basin and total treatment costs are minimized simultaneously. In both scenarios, the equity index and the WLA based on trading discharge permits (TDP) are calculated. The comparative results showed that using economically optimized TMDLs (2nd scenario) has slightly more cost savings rather than uniform TMDL approach (1st scenario). The former annually costs about 1 M$ while the latter is 1.15 M$. WQT can decrease these annual costs to 0.9 and 1.1 M$, respectively. In other word, these approaches may save 35 and 45% economically in comparison with command and control policy. It means that using multi objective decision support systems (DSS) may find more economical WLA, however its outcome is not necessarily significant in comparison with uniform TMDLs. This may be due to the similar impact factors of dischargers in small catchments. Conversely, using uniform TMDLs for WQT brings more equity that makes stakeholders not feel that much envious of difference between TMDL and WQT allocation. In addition, for this case, determination of TMDLs uniformly would be much easier for monitoring. Consequently, uniform TMDL for TDP market is recommended as a sustainable approach. However, economical TMDLs can be used for larger watersheds.Keywords: waste load allocation (WLA), water quality trading (WQT), total maximum daily loads (TMDLs), Haraz River, multi objective particle swarm optimization (MOPSO), equity
Procedia PDF Downloads 3943025 A Calibration Method for Temperature Distribution Measurement of Thermochromic Liquid Crystal Based on Mathematical Morphology of Hue Image
Authors: Risti Suryantari, Flaviana
Abstract:
The aim of this research is to design calibration method of Thermochromic Liquid Crystal for temperature distribution measurement based on mathematical morphology of hue image A glass of water is placed on the surface of sample TLC R25C5W at certain temperature. We use scanner for image acquisition. The true images in RGB format is converted to HSV (hue, saturation, value) by taking of hue without saturation and value. Then the hue images is processed based on mathematical morphology using Matlab2013a software to get better images. There are differences on the final images after processing at each temperature variation based on visualization observation and the statistic value. The value of maximum and mean increase with rising temperature. It could be parameter to identify the temperature of the human body surface like hand or foot surface.Keywords: thermochromic liquid crystal, TLC, mathematical morphology, hue image
Procedia PDF Downloads 4723024 An Experimental Study to Control Single Droplet by Actuating Waveform with Preliminary and Suppressing Vibration
Authors: Oke Oktavianty, Tadayuki Kyoutani, Shigeyuki Haruyama, Ken Kaminishi
Abstract:
For advancing the experiment system standard of Inkjet printer that is being developed, the actual natural period, fire limitation number in droplet weight measurement and observation distance in droplet velocity measurement was investigated. In another side, the study to control the droplet volume in inkjet printer with negative actuating waveform method is still limited. Therefore, the effect of negative waveform with preliminary and suppressing vibration addition on the droplet formation process, droplet shape, volume and velocity were evaluated. The different voltage and print-head temperature were exerted to obtain the optimum preliminary and suppressing vibration. The mechanism of different phenomenon from each waveform was also discussed.
Keywords: inkjet printer, DoD, waveform, preliminary and suppressing vibration
Procedia PDF Downloads 2393023 Audit Outcome Cardiac Arrest Cases (2019-2020) in Emergency Department RIPAS Hospital, Brunei Darussalam
Authors: Victor Au, Khin Maung Than, Zaw Win Aung, Linawati Jumat
Abstract:
Background & Objectives: Cardiac arrests can occur anywhere or anytime, and most of the cases will be brought to the emergency department except the cases that happened in at in-patient setting. Raja IsteriPangiran Anak Saleha (RIPAS) Hospital is the only tertiary government hospital which located in Brunei Muara district and received all referral from other Brunei districts. Data of cardiac arrests in Brunei Darussalam scattered between Emergency Medical Ambulance Services (EMAS), Emergency Department (ED), general inpatient wards, and Intensive Care Unit (ICU). In this audit, we only focused on cardiac arrest cases which had happened or presented to the emergency department RIPAS Hospital. Theobjectives of this audit were to look at demographic of cardiac arrest cases and the survival to discharge rate of In-Hospital Cardiac Arrest (IHCA) and Out-Hospital Cardiac Arrest (OHCA). Methodology: This audit retrospective study was conducted on all cardiac arrest cases that underwent Cardiopulmonary Resuscitation (CPR) in ED RIPAS Hospital, Brunei Muara, in the year 2019-2020. All cardiac arrest cases that happened or were brought in to emergency department were included. All the relevant data were retrieved from ED visit registry book and electronic medical record “Bru-HIMS” with keyword diagnosis of “cardiac arrest”. Data were analyzed and tabulated using Excel software. Result: 313 cardiac arrests were recorded in the emergency department in year 2019-2020. 92% cases were categorized as OHCA, and the remaining 8% as IHCA. Majority of the cases were male with age between 50-60 years old. In OHCA subgroup, only 12.4% received bystander CPR, and 0.4% received Automatic External Defibrillator (AED) before emergency medical personnel arrived. Initial shockable rhythm in IHCA group accounted for 12% compare to 4.9% in OHCA group. Outcome of ED resuscitation, 32% of IHCA group achieved return of spontaneous circulation (ROSC) with a survival to discharge rate was 16%. For OHCA group, 12.35% achieved ROSC, but unfortunately, none of them survive till discharge. Conclusion: Standardized registry for cardiac arrest in the emergency department is required to provide valid baseline data to measure the quality and outcome of cardiac arrest. Zero survival rate for out hospital cardiac arrest is very concerning, and it might represent the significant breach in cardiac arrest chains of survival. Systematic prospective data collection is needed to identify contributing factors and to improve resuscitation outcome.Keywords: cardiac arrest, OHCA, IHCA, resuscitation, emergency department
Procedia PDF Downloads 993022 Hydrodynamic Modeling of the Hydraulic Threshold El Haouareb
Authors: Sebai Amal, Massuel Sylvain
Abstract:
Groundwater is the key element of the development of most of the semi-arid areas where water resources are increasingly scarce due to an irregularity of precipitation, on the one hand, and an increasing demand on the other hand. This is the case of the watershed of the Central Tunisia Merguellil, object of the present study, which focuses on an implementation of an underground flows hydrodynamic model to understand the recharge processes of the Kairouan’s plain groundwater by aquifers boundary through the hydraulic threshold of El Haouareb. The construction of a conceptual geological 3D model by the Hydro GeoBuilder software has led to a definition of the aquifers geometry in the studied area thanks to the data acquired by the analysis of geologic sections of drilling and piezometers crossed shells partially or in full. Overall analyses of the piezometric Chronicles of different piezometers located at the level of the dam indicate that the influence of the dam is felt especially in the aquifer carbonate which confirms that the dynamics of this aquifer are highly correlated to the dam’s dynamic. Groundwater maps, high and low-water dam, show a flow that moves towards the threshold of El Haouareb to the discharge of the waters of Ain El Beidha discharge towards the plain of Kairouan. Software FEFLOW 5.2 steady hydrodynamic modeling to simulate the hydraulic threshold at the level of the dam El Haouareb in a satisfactory manner. However, the sensitivity study to the different parameters shows equivalence problems and a fix to calibrate the limestones’ permeability. This work could be improved by refining the timing steady and amending the representation of limestones in the model.Keywords: Hydrodynamic modeling, lithological modeling, hydraulic, semi-arid, merguellil, central Tunisia
Procedia PDF Downloads 7643021 Effect of Bull Exposure on Post-Partum Estrus Interval in Nili-Ravi Buffaloes
Authors: Muhammad Saleem Akhtar, Mushtaq Hussain Lashari, Ejaz Ahmad, Tanveer Ahmad, Laeeq Akbar Lodhi, Ijaz Ahmad, Masood Akhtar
Abstract:
The objective of this study was to determine the effect of bull exposure continuously or intermittently or its excretory products after calving on postpartum interval to estrus, in Nili-Ravi buffalo. Forty-eight buffaloes of Nili-Ravi breed were allocated one of the four treatments in a totally randomized plan using a 4 x 1 factorial design. The four treatment groups were BEC (Bull Exposed Continuously), BEI (Bull Exposed Intermittently), EPB (Excretory Products of Bull) and BNE (Bull Not Exposed). BEC; buffaloes (n = 12) were exposed continuously to the physical presence of a bull whereas in BEI; buffaloes (n = 12) were exposed intermittently to the physical presence of bull. EPB; buffaloes (n = 12) were exposed to discharge waste (urine and feces) of bull and BNE buffaloes (n = 12) were not exposed to a bull or discharge waste of bulls. Buffaloes were exposed on day 15 after parturition. Day 15 postpartum represented d 0 for each treatment. The postpartum interval from calving to first behavioural estrus was 66.88 days in BEC, 75.12 days in BEI, 77.28 days in EPB and 76.5 days in BNE treatments. Postpartum interval to first behavioural estrus was shorter in BEC than BEI, EPB, and BNE treatments. There was no significant difference in postpartum interval to estrus between BEI, EPB and BNE treatments. In present study, the percentage of buffaloes showing estrus during experimental period was 75.0%, 66.66%, 66.66% and 58.33% in BEC, BEI, EPB and BNE treatments, respectively. The mean serum progesterone concentration did not differ significantly between BEC and other (BEI, EPB, and BNE) treatments. It was concluded that presence of bull has positive effect in reducing calving interval in Nili Ravi buffalo.Keywords: calving interval, biostimulation, buffalo, bull exposure
Procedia PDF Downloads 2553020 Learning Participation and Baby Care Ability in Mothers of Preterm Infant
Authors: Yi-Chuan Cheng, Li-Chi Huang, Yu-Shan Chang
Abstract:
Introduction: The main purpose of this study was to explore the relationship between the learning number, care knowledge, care skills and maternal confidence in preterm infant care in Taiwan. Background: Preterm infants care has been stressful for mother caring at home. Many programs have been applied for improving the infant care maternal confident. But less to know the learning behavior in mothers of preterm infant. Methods: The sample consisted of 55 mothers with preterm infants were recruited in a neonatal intermediate unit at a medical center in central Taiwan. The self-reported questionnaires including knowledge and skills of preterm infant care scales and maternal confidence scale were used to evaluation, which were conducted during hospitalization, before hospital discharge, and one month after discharge. We performed by using Pearson correlation of the collected data using SPSS 18. Results: The study showed that the learning number and knowledge in preterm infant care was a significant positive correlation (r = .40), and the skills and confidence preterm infant care was positively correlated (r = .89). Conclusions: Study results showed the mother had more learning number in preterm infant care will be stronger knowledge, and the skills and confidence in preterm infant care were also positively correlated. Thus, we found the learning behavior change significant care knowledge. And the maternal confidence change significant with skill on preterm infant’s care. But bondage still needs further study and develop the participation in hospital-based instructional programs, which could lead to greater long-term retention of learning.Keywords: learning behavior, care knowledge, care skills, maternal confidence
Procedia PDF Downloads 2603019 Durable Phantom Production Identical to Breast Tissue for Use in Breast Cancer Detection Research Studies
Authors: Hayrettin Eroglu, Adem Kara
Abstract:
Recently there has been significant attention given to imaging of the biological tissues via microwave imaging techniques. In this study, a phantom for the test and calibration of Microwave imaging used in detecting unhealthy breast structure or tumors was produced by using sol gel method. The liquid and gel phantoms being used nowadays are not durable due to evaporation and their organic ingredients, hence a new design was proposed. This phantom was fabricated from materials that were widely available (water, salt, gelatin, and glycerol) and was easy to make. This phantom was aimed to be better from the ones already proposed in the literature in terms of its durability and stability. S Parameters of phantom was measured with 1-18 GHz Probe Kit and permittivity was calculated via Debye method in “85070” commercial software. One, three, and five-week measurements were taken for this phantom. Finally, it was verified that measurement results were very close to the real biological tissue measurement results.Keywords: phantom, breast tissue, cancer, microwave imaging
Procedia PDF Downloads 3553018 Reinforcement Learning the Born Rule from Photon Detection
Authors: Rodrigo S. Piera, Jailson Sales Ara´ujo, Gabriela B. Lemos, Matthew B. Weiss, John B. DeBrota, Gabriel H. Aguilar, Jacques L. Pienaar
Abstract:
The Born rule was historically viewed as an independent axiom of quantum mechanics until Gleason derived it in 1957 by assuming the Hilbert space structure of quantum measurements [1]. In subsequent decades there have been diverse proposals to derive the Born rule starting from even more basic assumptions [2]. In this work, we demonstrate that a simple reinforcement-learning algorithm, having no pre-programmed assumptions about quantum theory, will nevertheless converge to a behaviour pattern that accords with the Born rule, when tasked with predicting the output of a quantum optical implementation of a symmetric informationally-complete measurement (SIC). Our findings support a hypothesis due to QBism (the subjective Bayesian approach to quantum theory), which states that the Born rule can be thought of as a normative rule for making decisions in a quantum world [3].Keywords: quantum Bayesianism, quantum theory, quantum information, quantum measurement
Procedia PDF Downloads 1083017 The Systemic Approach to Risk Measurement of Drainage Systems in Urban Areas
Authors: Jadwiga Królikowska, Andrzej Królikowski, Jarosław Bajer
Abstract:
The work delineates the threats of maladjustment of the capacity of rain canals, designed and built in the early 20th century, in connection to heavy rainfall, especially in summer. This is the cause of the so called 'urban floods.' It directly relates to fierce raise of paving in the cities. Resolving this problem requires a change in philosophy of draining the rainfall by wider use of retention, infiltration and usage of rainwater. In systemic approach to managing the safety of urban drainage systems the risk, which is directly connected to safety failures, has been accepted as a measure. The risk level defines the probability of occurrence of losses grater than the ones forecast for a given time frame. The procedure of risk modelling, enabling its numeric analysis by using appropriate weights, is a significant issue in this paper.Keywords: drainage system, urban areas, risk measurement, systemic approach
Procedia PDF Downloads 2943016 Full-Field Estimation of Cyclic Threshold Shear Strain
Authors: E. E. S. Uy, T. Noda, K. Nakai, J. R. Dungca
Abstract:
Cyclic threshold shear strain is the cyclic shear strain amplitude that serves as the indicator of the development of pore water pressure. The parameter can be obtained by performing either cyclic triaxial test, shaking table test, cyclic simple shear or resonant column. In a cyclic triaxial test, other researchers install measuring devices in close proximity of the soil to measure the parameter. In this study, an attempt was made to estimate the cyclic threshold shear strain parameter using full-field measurement technique. The technique uses a camera to monitor and measure the movement of the soil. For this study, the technique was incorporated in a strain-controlled consolidated undrained cyclic triaxial test. Calibration of the camera was first performed to ensure that the camera can properly measure the deformation under cyclic loading. Its capacity to measure deformation was also investigated using a cylindrical rubber dummy. Two-dimensional image processing was implemented. Lucas and Kanade optical flow algorithm was applied to track the movement of the soil particles. Results from the full-field measurement technique were compared with the results from the linear variable displacement transducer. A range of values was determined from the estimation. This was due to the nonhomogeneous deformation of the soil observed during the cyclic loading. The minimum values were in the order of 10-2% in some areas of the specimen.Keywords: cyclic loading, cyclic threshold shear strain, full-field measurement, optical flow
Procedia PDF Downloads 2343015 Measurement and Research of Green Office Building Operational Performance in China: A Case Study of a Green Office Building in Zhejiang Province
Authors: Xuechen Gui, Jian Ge, Senmiao Li
Abstract:
In recent years, green buildings in China have been developing rapidly and have developed into a wide variety of types, of which office building is a very important part. In many green office buildings, the energy consumption of building operation is high; the indoor environment quality needs to be improved, and the level of occupants’ satisfaction is low. This paper conducted a one-year measurement of operational performance of a green office building in Zhejiang Province. The measurement includes energy consumption of the building's one-year operation, the quality of the indoor environment and occupants’ satisfaction in different seasons. The energy consumption is collected from the power bureau. The quality of the indoor environment have been measured at different measuring points including offices, meeting rooms and reception for the whole year. The satisfaction of occupants are obtained from questionnaires. The results are compared with given standards and goals and the reasons why occupants are dissatisfied with the indoor environment are analyzed. Regarding energy consumption, the energy consumption of the building operational performance is much higher than the standard. Regarding the indoor environment, the temperature and humidity meet the standard for most of the time, but fine particulate matter (PM2.5) concentration is pretty high. Regarding occupants satisfaction, occupants have a higher expectation for indoor air quality even when the indoor air quality is well and occupants prefer a relatively humid environment. However the overall satisfaction is more than 80%, which indicates that occupants have a higher tolerability.Keywords: green office building, energy consumption, indoor environment quality, occupants satisfaction, operational performance
Procedia PDF Downloads 1773014 Measurement of Steady Streaming from an Oscillating Bubble Using Particle Image Velocimetry
Authors: Yongseok Kwon, Woowon Jeong, Eunjin Cho, Sangkug Chung, Kyehan Rhee
Abstract:
Steady streaming flow fields induced by a 500 um bubble oscillating at 12 kHz were measured using microscopic particle image velocimetry (PIV). The accuracy of velocity measurement using a micro PIV system was checked by comparing the measured velocity fields with the theoretical velocity profiles in fully developed laminar flow. The steady streaming flow velocities were measured in the saggital plane of the bubble attached on the wall. Measured velocity fields showed upward jet flow with two symmetric counter-rotating vortices, and the maximum streaming velocity was about 12 mm/s, which was within the velocity ranges measured by other researchers. The measured streamlines were compared with the analytic solution, and they also showed a reasonable agreement.Keywords: oscillating bubble, particle image velocimetry, microstreaming, vortices,
Procedia PDF Downloads 4133013 Measurement of Ionospheric Plasma Distribution over Myanmar Using Single Frequency Global Positioning System Receiver
Authors: Win Zaw Hein, Khin Sandar Linn, Su Su Yi Mon, Yoshitaka Goto
Abstract:
The Earth ionosphere is located at the altitude of about 70 km to several 100 km from the ground, and it is composed of ions and electrons called plasma. In the ionosphere, these plasma makes delay in GPS (Global Positioning System) signals and reflect in radio waves. The delay along the signal path from the satellite to the receiver is directly proportional to the total electron content (TEC) of plasma, and this delay is the largest error factor in satellite positioning and navigation. Sounding observation from the top and bottom of the ionosphere was popular to investigate such ionospheric plasma for a long time. Recently, continuous monitoring of the TEC using networks of GNSS (Global Navigation Satellite System) observation stations, which are basically built for land survey, has been conducted in several countries. However, in these stations, multi-frequency support receivers are installed to estimate the effect of plasma delay using their frequency dependence and the cost of multi-frequency support receivers are much higher than single frequency support GPS receiver. In this research, single frequency GPS receiver was used instead of expensive multi-frequency GNSS receivers to measure the ionospheric plasma variation such as vertical TEC distribution. In this measurement, single-frequency support ublox GPS receiver was used to probe ionospheric TEC. The location of observation was assigned at Mandalay Technological University in Myanmar. In the method, the ionospheric TEC distribution is represented by polynomial functions for latitude and longitude, and parameters of the functions are determined by least-squares fitting on pseudorange data obtained at a known location under an assumption of thin layer ionosphere. The validity of the method was evaluated by measurements obtained by the Japanese GNSS observation network called GEONET. The performance of measurement results using single-frequency of GPS receiver was compared with the results by dual-frequency measurement.Keywords: ionosphere, global positioning system, GPS, ionospheric delay, total electron content, TEC
Procedia PDF Downloads 1373012 Real-Time Measurement Approach for Tracking the ΔV10 Estimate Value of DC EAF
Authors: Jin-Lung Guan, Jyh-Cherng Gu, Chun-Wei Huang, Hsin-Hung Chang
Abstract:
This investigation develops a revisable method for estimating the estimate value of equivalent 10 Hz voltage flicker (DV10) of a DC Electric Arc Furnace (EAF). This study also discusses three 161kV DC EAFs by field measurement, with those results indicating that the estimated DV10 value is significantly smaller than the survey value. The key point is that the conventional means of estimating DV10 is inappropriate. There is a main cause as the assumed Qmax is too small. Although DC EAF is regularly operated in a constant MVA mode, the reactive power variation in the Main Transformer (MT) is more significant than that in the Furnace Transformer (FT). A substantial difference exists between estimated maximum reactive power fluctuation (DQmax) and the survey value from actual DC EAF operations. However, this study proposes a revisable method that can obtain a more accurate DV10 estimate than the conventional method.Keywords: voltage flicker, dc EAF, estimate value, DV10
Procedia PDF Downloads 4483011 Supply Chain and Performance Measurement: An Alignment With Sustainable Development Goals
Authors: Miriam Corrado, Roberta Ciccola, Maria Serena Chiucchi
Abstract:
SDGs represent the last edge in the sustainability corporate practices, including the supply chain management. Supply chains are becoming more global and complex, can create more inclusive markets and make contribution to the advance of the sustainable development. In corporate practices, the presence of sustainability criteria in supply chain management could offer an opportunity to increase competitiveness and to meet stakeholders’ expectations in terms of sustainability and corporate accountability. The research aims to understand how focal companies can integrate SDGs in their supply chain and how they can measure and assess their impacts on SDGs. The study adopts a multiple case study methodology based on four case studies referred to companies committed in measuring SDGs’ performance in their supply chains. Preliminary findings demonstrate the willingness and the need of companies to commit under a supply-chain perspective for the achievement of SDGs. Companies recognize their role in impacting the SDGs through their procurement choices by defining and implementing an SDGs scoring system. The contribution of the study is twofold: first, given the lack of research and studies addressing the integration of SDGs in the supply chain and in the performance measurement systems, the research provides a contribution to the current academic literature in relation to these emerging gaps; second, the research provides a practical guidance to implement a sustainable supply chain and advance towards the achievement of SDGs.Keywords: sustainable supply chains, sustainable development goals, performance measurement, performance management
Procedia PDF Downloads 1953010 Stent Surface Functionalisation via Plasma Treatment to Promote Fast Endothelialisation
Authors: Irene Carmagnola, Valeria Chiono, Sandra Pacharra, Jochen Salber, Sean McMahon, Chris Lovell, Pooja Basnett, Barbara Lukasiewicz, Ipsita Roy, Xiang Zhang, Gianluca Ciardelli
Abstract:
Thrombosis and restenosis after stenting procedure can be prevented by promoting fast stent wall endothelialisation. It is well known that surface functionalisation with antifouling molecules combining with extracellular matrix proteins is a promising strategy to design biomimetic surfaces able to promote fast endothelialization. In particular, REDV has gained much attention for the ability to enhance rapid endothelialization due to its specific affinity with endothelial cells (ECs). In this work, a two-step plasma treatment was performed to polymerize a thin layer of acrylic acid, used to subsequently graft PEGylated-REDV and polyethylene glycol (PEG) at different molar ratio with the aim to selectively promote endothelial cell adhesion avoiding platelet activation. PEGylate-REDV was provided by Biomatik and it is formed by 6 PEG monomer repetitions (Chempep Inc.), with an NH2 terminal group. PEG polymers were purchased from Chempep Inc. with two different chain lengths: m-PEG6-NH2 (295.4 Da) with 6 monomer repetitions and m-PEG12-NH2 (559.7 Da) with 12 monomer repetitions. Plasma activation was obtained by operating at 50W power, 5 min of treatment and at an Ar flow rate of 20 sccm. Pure acrylic acid (99%, AAc) vapors were diluted in Ar (flow = 20 sccm) and polymerized by a pulsed plasma discharge applying a discharge RF power of 200 W, a duty cycle of 10% (on time = 10 ms, off time = 90 ms) for 10 min. After plasma treatment, samples were dipped into an 1-(3-dimethylaminopropyl)-3- ethylcarbodiimide (EDC)/N-hydroxysuccinimide (NHS) solution (ratio 4:1, pH 5.5) for 1 h at 4°C and subsequently dipped in PEGylate-REDV and PEGylate-REDV:PEG solutions at different molar ratio (100 μg/mL in PBS) for 20 h at room temperature. Surface modification was characterized through physico-chemical analyses and in vitro cell tests. PEGylated-REDV peptide and PEG were successfully bound to the carboxylic groups that are formed on the polymer surface after plasma reaction. FTIR-ATR spectroscopy, X -ray Photoelectron Spectroscopy (XPS) and contact angle measurement gave a clear indication of the presence of the grafted molecules. The use of PEG as a spacer allowed for an increase in wettability of the surface, and the effect was more evident by increasing the amount of PEG. Endothelial cells adhered and spread well on the surfaces functionalized with the REDV sequence. In conclusion, a selective coating able to promote a new endothelial cell layer on polymeric stent surface was developed. In particular, a thin AAc film was polymerised on the polymeric surface in order to expose –COOH groups, and PEGylate-REDV and PEG were successful grafted on the polymeric substrates. The REDV peptide demonstrated to encourage cell adhesion with a consequent, expected improvement of the hemocompatibility of these polymeric surfaces in vivo. Acknowledgements— This work was funded by the European Commission 7th Framework Programme under grant agreement number 604251- ReBioStent (Reinforced Bioresorbable Biomaterials for Therapeutic Drug Eluting Stents). The authors thank all the ReBioStent partners for their support in this work.Keywords: endothelialisation, plasma treatment, stent, surface functionalisation
Procedia PDF Downloads 3113009 Flow Characteristics around Rectangular Obstacles with the Varying Direction of Obstacles
Authors: Hee-Chang Lim
Abstract:
The study aims to understand the surface pressure distribution around the bodies such as the suction pressure in the leading edge on the top and side-face when the aspect ratio of bodies and the wind direction are changed, respectively. We carried out the wind tunnel measurement and numerical simulation around a series of rectangular bodies (40d×80w×80h, 80d×80w×80h, 160d×80w×80h, 80d×40w×80h and 80d×160w×80h in mm3) placed in a deep turbulent boundary layer. Based on a modern numerical platform, the Navier-Stokes equation with the typical 2-equation (k-ε model) and the DES (Detached Eddy Simulation) turbulence model has been calculated, and they are both compared with the measurement data. Regarding the turbulence model, the DES model makes a better prediction comparing with the k-ε model, especially when calculating the separated turbulent flow around a bluff body with sharp edged corner. In order to observe the effect of wind direction on the pressure variation around the cube (e.g., 80d×80w×80h in mm), it rotates at 0º, 10º, 20º, 30º, and 45º, which stands for the salient wind directions in the tunnel. The result shows that the surface pressure variation is highly dependent upon the approaching wind direction, especially on the top and the side-face of the cube. In addition, the transverse width has a substantial effect on the variation of surface pressure around the bodies, while the longitudinal length has little or no influence.Keywords: rectangular bodies, wind direction, aspect ratio, surface pressure distribution, wind-tunnel measurement, k-ε model, DES model, CFD
Procedia PDF Downloads 2353008 Barrier Characteristics of Molecular Semiconductor-Based Organic/Inorganic Au/C₄₂H₂₈/n-InP Hybrid Junctions
Authors: Bahattin Abay
Abstract:
Thin film of polycyclic aromatic hydrocarbon rubrene, C₄₂H₂₈ (5,6,11,12-tetraphenyltetracene), has been surfaced on Moderately Doped (MD) n-InP substrate as an interfacial layer by means of spin coating technique for the electronic modification of Au/MD n-InP structure. Ex situ annealing has been carried out at 150 °C for three minutes under a brisk flow of nitrogen for the better adhesion of the deposited film with the substrate surface. Room temperature electrical characterization has been performed on the C₄₂H₂₈/MD n-InP hybrid junctions by current-voltage (I-V) and capacitance-voltage (C-V) measurement in the dark. It has been seen that the C₄₂H₂₈/MD n-InP structure demonstrated extraordinary rectifying behavior. An effective barrier height (BH) as high as 0.743 eV, along with an ideality factor very close to unity (n=1.203), has been achieved for C₄₂H₂₈/n-InP organic/inorganic device. A thin C₄₂H₂₈ interfacial layer between Au and MD n-InP also reduce the reverse leakage current by almost four orders of magnitude and enhance the BH about 0.278 eV. This good performance of the device is ascribed to the passivation effect of organic interfacial layer between Au and n-InP. By using C-V measurement, in addition, the value of BH of the C₄₂H₂₈/n-InP organic/inorganic hybrid junctions have been obtained as 0.796 eV. It has been seen that both of the BH value (0.743 and 0.796 eV) for the organic/inorganic hybrid junction obtained I-V and C-V measurement, respectively are significantly larger than that of the conventional Au/n-InP structure (0.465 and 0.503 eV). It was also seen that the device had good sensitivity to the light under 100 mW/cm² illumination conditions. The obtained results indicated that modification of the interfacial potential barrier for Metal/n-InP junctions might be attained using polycyclic aromatic hydrocarbon thin interlayer C₄₂H₂₈.Keywords: I-V and C-V measurements, heterojunction, n-InP, rubrene, surface passivation
Procedia PDF Downloads 1623007 Measurement of Nasal Septal Cartilage in Adult Filipinos Using Computed Tomography
Authors: Miguel Limbert Ramos, Joseph Amado Galvez
Abstract:
Background: The nasal septal cartilage is an autologous graft that is widely used in different otolaryngologic procedures of the different subspecialties, such as in septorhinoplasty and ear rehabilitation procedures. The cartilage can be easily accessed and harvested to be utilized for such procedures. However, the dimension of the nasal septal cartilage differs, corresponding to race, gender, and age. Measurements can be done via direct measurement of harvested septal cartilage in cadavers or utilizing radiographic imaging studies giving baseline measurement of the nasal septal cartilage distinct to every race. A preliminary baseline measurement of the dimensions of Filipino nasal septal cartilage was previously established by measuring harvested nasal septal cartilage in Filipino Malay cadavers. This study intends to reinforce this baseline measurement by utilizing computed tomography (CT) scans of adult Filipinos in a tertiary government hospital in the City of Manila, Philippines, which will cover a larger sampling population. Methods: The unit of observation and analysis will be the computed tomography (CT) scans of patients ≥ 18years old who underwent cranial, facial, orbital, paranasal sinus, and temporal bone studies for the year 2019. The measurements will be done in a generated best midsagittal image (155 subjects) which is a view through the midline of the cerebrum that is simultaneously viewed with its coronal and axial views for proper orientation. The view should reveal important structures that will be used to plot the anatomic boundaries, which will be measured by a DICOM image viewing software (RadiAnt). The measured area of nasal septal cartilage will be compared by gender and age. Results: The total area of the nasal septal cartilage is larger in males compared to females, with a mean value of 6.52 cm² and 5.71 cm², respectively. The harvestable nasal septal cartilage area is also larger in males with a mean value of 3.57 cm² compared to females with only a measured mean value of 3.13 cm². The total and harvestable area of the nasal septal cartilage is largest in the 18-30 year-old age group with a mean value of 6.47 cm² and 3.60 cm² respectively and tends to decrease with the advancement of age, which can be attributed to continuous ossification changes. Conclusion: The best time to perform septorhinoplasty and other otolaryngologic procedures which utilize the nasal septal cartilage as graft material is during post-pubertal age, hence surgeries should be avoided or delayed to allow growth and maturation of the cartilage. A computed tomography scan is a cost-effective and non-invasive tool that can provide information on septal cartilage areas prior to these procedures.Keywords: autologous graft, computed tomography, nasal septal cartilage, septorhinoplasty
Procedia PDF Downloads 1583006 The Development of a Residual Stress Measurement Method for Roll Formed Products
Authors: Yong Sun, Vladimir Luzin, Zhen Qian, William J. T. Daniel, Mingxing Zhang, Shichao Ding
Abstract:
The residual stresses in roll formed products are generally very high and un-predictable. This is due to the occurrence of redundant plastic deformation in roll forming process and it can cause various product defects. Although the residual stresses of a roll formed product consist of longitudinal and transverse residual stresses components, but the longitudinal residual stresses plays a key role to the product defects of a roll formed product and therefore, only the longitudinal residual stresses concerned by the roll forming scholars and engineers. However, how to inspect the residual stresses of a product quickly and economically as a routine operation is still a challenge. This paper introduces a residual stresses measurement method called slope cutting method to study the longitudinal residual stresses through layers geometrically to a roll formed products or a product with similar process such as a rolled sheet. The detailed measuring procedure is given and discussed. The residual stresses variation through the layer can be derived based on the variation of curvature in different layers and steps. The slope cutting method has been explored and validated by experimental study on a roll-formed square tube. The neutron diffraction method is applied to validate the accuracy of the newly proposed layering removal materials results. The two set results agree with each other very well and therefore, the method is expected to be a routine testing method to monitor the quality of a product been formed and that is a great impact to roll forming industry.Keywords: roll forming, residual stress, measurement method, neutron diffraction
Procedia PDF Downloads 3643005 A Paradigm for Characterization and Checking of a Human Noise Behavior
Authors: Himanshu Dehra
Abstract:
This paper presents a paradigm for characterization and checking of human noise behavior. The definitions of ‘Noise’ and ‘Noise Behavior’ are devised. The concept of characterization and examining of Noise Behavior is obtained from the proposed paradigm of Psychoacoustics. The measurement of human noise behavior is discussed through definitions of noise sources and noise measurements. The noise sources, noise measurement equations and noise filters are further illustrated through examples. The theory and significance of solar energy acoustics is presented for life and its activities. Human comfort and health are correlated with human brain through physiological responses and noise protection. Examples of heat stress, intense heat, sweating and evaporation are also enumerated.Keywords: human brain, noise behavior, noise characterization, noise filters, physiological responses, psychoacoustics
Procedia PDF Downloads 5083004 Impact of Changes of the Conceptual Framework for Financial Reporting on the Indicators of the Financial Statement
Authors: Nadezhda Kvatashidze
Abstract:
The International Accounting Standards Board updated the conceptual framework for financial reporting. The main reason behind it is to resolve the tasks of the accounting, which are caused by the market development and business-transactions of a new economic content. Also, the investors call for higher transparency of information and responsibility for the results in order to make a more accurate risk assessment and forecast. All these make it necessary to further develop the conceptual framework for financial reporting so that the users get useful information. The market development and certain shortcomings of the conceptual framework revealed in practice require its reconsideration and finding new solutions. Some issues and concepts, such as disclosure and supply of information, its qualitative characteristics, assessment, and measurement uncertainty had to be supplemented and perfected. The criteria of recognition of certain elements (assets and liabilities) of reporting had to be updated, too and all this is set out in the updated edition of the conceptual framework for financial reporting, a comprehensive collection of concepts underlying preparation of the financial statement. The main objective of conceptual framework revision is to improve financial reporting and development of clear concepts package. This will support International Accounting Standards Board (IASB) to set common “Approach & Reflection” for similar transactions on the basis of mutually accepted concepts. As a result, companies will be able to develop coherent accounting policies for those transactions or events that are occurred from particular deals to which no standard is used or when standard allows choice of accounting policy.Keywords: conceptual framework, measurement basis, measurement uncertainty, neutrality, prudence, stewardship
Procedia PDF Downloads 1263003 An Efficient Automated Radiation Measuring System for Plasma Monopole Antenna
Authors: Gurkirandeep Kaur, Rana Pratap Yadav
Abstract:
This experimental study is aimed to examine the radiation characteristics of different plasma structures of a surface wave-driven plasma antenna by an automated measuring system. In this study, a 30 cm long plasma column of argon gas with a diameter of 3 cm is excited by surface wave discharge mechanism operating at 13.56 MHz with RF power level up to 100 Watts and gas pressure between 0.01 to 0.05 mb. The study reveals that a single structured plasma monopole can be modified into an array of plasma antenna elements by forming multiple striations or plasma blobs inside the discharge tube by altering the values of plasma properties such as working pressure, operating frequency, input RF power, discharge tube dimensions, i.e., length, radius, and thickness. It is also reported that plasma length, electron density, and conductivity are functions of operating plasma parameters and controlled by changing working pressure and input power. To investigate the antenna radiation efficiency for the far-field region, an automation-based radiation measuring system has been fabricated and presented in detail. This developed automated system involves a combined setup of controller, dc servo motors, vector network analyzer, and computing device to evaluate the radiation intensity, directivity, gain and efficiency of plasma antenna. In this system, the controller is connected to multiple motors for moving aluminum shafts in both elevation and azimuthal plane whereas radiation from plasma monopole antenna is measured by a Vector Network Analyser (VNA) which is further wired up with the computing device to display radiations in polar plot forms. Here, the radiation characteristics of both continuous and array plasma monopole antenna have been studied for various working plasma parameters. The experimental results clearly indicate that the plasma antenna is as efficient as a metallic antenna. The radiation from plasma monopole antenna is significantly influenced by plasma properties which provides a wider range in radiation pattern where desired radiation parameters like beam-width, the direction of radiation, radiation intensity, antenna efficiency, etc. can be achieved in a single monopole. Due to its wide range of selectivity in radiation pattern; this can meet the demands of wider bandwidth to get high data speed in communication systems. Moreover, this developed system provides an efficient and cost-effective solution for measuring the radiation pattern in far-field zone for any kind of antenna system.Keywords: antenna radiation characteristics, dynamically reconfigurable, plasma antenna, plasma column, plasma striations, surface wave
Procedia PDF Downloads 1193002 An AK-Chart for the Non-Normal Data
Authors: Chia-Hau Liu, Tai-Yue Wang
Abstract:
Traditional multivariate control charts assume that measurement from manufacturing processes follows a multivariate normal distribution. However, this assumption may not hold or may be difficult to verify because not all the measurement from manufacturing processes are normal distributed in practice. This study develops a new multivariate control chart for monitoring the processes with non-normal data. We propose a mechanism based on integrating the one-class classification method and the adaptive technique. The adaptive technique is used to improve the sensitivity to small shift on one-class classification in statistical process control. In addition, this design provides an easy way to allocate the value of type I error so it is easier to be implemented. Finally, the simulation study and the real data from industry are used to demonstrate the effectiveness of the propose control charts.Keywords: multivariate control chart, statistical process control, one-class classification method, non-normal data
Procedia PDF Downloads 4223001 Investigating Unplanned Applications and Admissions to Hospitals of Children with Cancer
Authors: Hacer Kobya Bulut, Ilknur Kahriman, Birsel C. Demirbag
Abstract:
Introduction and Purpose: The lives of children with cancer are affected by long term hospitalizations in a negative way due to complications arising from diagnosis or treatment. However, the children's parents are known to have difficulties in meeting their children’s needs and providing home care after cancer treatment or during remission process. Supporting these children and their parents by giving a planned discharge training starting from the hospital and home care leads to reducing hospital applications, hospitalizations, hospital costs, shortening the length of hospital stay and increasing the satisfaction of the children with cancer and their families. This study was conducted to investigate the status of children and their parents' unplanned application to hospital and re-hospitalization. Methods: The study was carried out with 65 children with hematological malignancy in 0-17 age group and their families in a hematology clinic and polyclinic of a university hospital in Trabzon. Data were collected with survey methodology between August-November, 2015 through face to face interview using numbers, percentage and chi-square test in the evaluation. Findings: Most of the children were leukemia (90.8%) and 49.2% had been ill over 13 months. Few of the parents (32.3%) stated that they had received discharge and home care training (24.6%) but most of them (69.2%) found themselves enough in providing home care. Very few parents (6.2%) received home care training after their children being discharged and the majority of parents (61.5%) faced difficulties in home care and had no one to call around them. The parents expressed that in providing care to their children with hematological malignance, they faced difficulty in feeding them (74.6%), explaining their disease (50.0%), giving their oral medication (47.5%), providing hygiene (43.5%) and providing oral care (39.3%). The question ‘What are the emergency situations in which you have to bring your children to a doctor immediately?' was replied as fever (89.2%), severe nausea and vomiting (87.7%), hemorrhage (86.2%) and pain (81.5%). The study showed that 50.8% of the children had unplanned applications to hospitals and 33.8% of them identified as unplanned hospitalization and the first causes of this were fever and pain. The study showed that the frequency of applications (%78.8) and hospitalizations (%81.8) was higher for boys and a statistically significant difference was found between gender and unplanned applications (X=4.779; p=0.02). Applications (48.5%) and hospitalizations (40.9%) were found lower for the parents who had received hospital discharge training, and a significant difference was determined between receiving training and unplanned hospitalizations (X=8.021; p=0.00). Similarly, applications (30.3%) and hospitalizations (40.9%) was found lower for the ones who had received home care training, and a significant difference was determined between receiving home care training and unplanned hospitalizations (X=4.758; p=0.02). Conclusion: It was found out that caregivers of children with cancer did not receive training related to home care and complications about treatment after discharging from hospital, so they faced difficulties in providing home care and this led to an increase in unplanned hospital applications and hospitalizations.Keywords: cancer, children, unplanned application, unplanned hospitalization
Procedia PDF Downloads 2683000 Effect of Perioperative Protocol of Care on Clinical Outcomes among Patients Undergoing Coronary Artery Bypass Graft
Authors: Manal Ahmed, Amal Shehata, Shereen Deeb
Abstract:
The study's purpose was to determine the effect of the perioperative protocol of care on clinical outcomes among patients undergoing coronary artery bypass graft. Subjects: A sample of 100 adult patients who were planned for coronary artery bypass graft, were selected and divided alternatively and randomly into two equal groups (50 study -50 control).The study was carried out at National heart Institute in Cairo and open heart surgical intensive care unit in Shebin El-Kom Teaching Hospital. Instruments: Four instruments were used for data collection: Interviewing questionnaire, dyspnea analogue scale, Biophysiological measurement instrument, and Compliance assessment sheet. Results: There were statistically significant differences between both groups regarding most respiratory system assessment findings at discharge. More than two-thirds of the study group of the current study had a continuous and regular commitment to diet regimen, which ranked first followed by the compliance of daily living activities then quitting smoking. Conclusions: The perioperative protocol of care has a significant improving effect on respiratory findings, dyspnea degree, duration of mechanical ventilation, length of hospital stay, compliance to diet, therapeutic regimen, daily living activities, and quit smoking among study group undergoing CABG. Recommendations: Perioperative protocol of care should be carried out for CABG patients at open-heart surgical units as well as an illustrative colored booklet about CAD, CABG and perioperative care should be available and distributed to all CABG patients.Keywords: perioperative, effect, clinical outcomes, coronary artery, bypass graft, protocol of care
Procedia PDF Downloads 139