Search results for: contrast-enhanced computed tomography scan
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1353

Search results for: contrast-enhanced computed tomography scan

1083 Applying Multiple Kinect on the Development of a Rapid 3D Mannequin Scan Platform

Authors: Shih-Wen Hsiao, Yi-Cheng Tsao

Abstract:

In the field of reverse engineering and creative industries, applying 3D scanning process to obtain geometric forms of the objects is a mature and common technique. For instance, organic objects such as faces and nonorganic objects such as products could be scanned to acquire the geometric information for further application. However, although the data resolution of 3D scanning device is increasing and there are more and more abundant complementary applications, the penetration rate of 3D scanning for the public is still limited by the relative high price of the devices. On the other hand, Kinect, released by Microsoft, is known for its powerful functions, considerably low price, and complete technology and database support. Therefore, related studies can be done with the applying of Kinect under acceptable cost and data precision. Due to the fact that Kinect utilizes optical mechanism to extracting depth information, limitations are found due to the reason of the straight path of the light. Thus, various angles are required sequentially to obtain the complete 3D information of the object when applying a single Kinect for 3D scanning. The integration process which combines the 3D data from different angles by certain algorithms is also required. This sequential scanning process costs much time and the complex integration process often encounter some technical problems. Therefore, this paper aimed to apply multiple Kinects simultaneously on the field of developing a rapid 3D mannequin scan platform and proposed suggestions on the number and angles of Kinects. In the content, a method of establishing the coordination based on the relation between mannequin and the specifications of Kinect is proposed, and a suggestion of angles and number of Kinects is also described. An experiment of applying multiple Kinect on the scanning of 3D mannequin is constructed by Microsoft API, and the results show that the time required for scanning and technical threshold can be reduced in the industries of fashion and garment design.

Keywords: 3D scan, depth sensor, fashion and garment design, mannequin, multiple Kinect sensor

Procedia PDF Downloads 345
1082 Examination of the Influence of the Near-Surface Geology on the Initial Infrastructural Development Using High-Resolution Seismic Method

Authors: Collins Chiemeke, Stephen Ibe, Godwin Onyedim

Abstract:

This research work on high-resolution seismic tomography method was carried out with the aim of investigating how near-surface geology influences the initial distribution of infrastructural development in an area like Otuoke and its environs. To achieve this objective, seismic tomography method was employed. The result revealed that the overburden (highly-weathered layer) thickness ranges from 27 m to 50 m within the survey area, with an average value of 37 m. The 3D surface analysis for the overburden thickness distribution within the survey area showed that the thickness of the overburden is more in regions with less infrastructural development, and least in built-up areas. The range of velocity distribution from the surface to within a depth of 5 m is about 660 m/s to 1160 m/s, with an average value of 946 m/s. The 3D surface analysis of the velocity distribution also revealed that the areas with large infrastructural development are characterized with large velocity values compared with the undeveloped regions that has average low-velocity values. Hence, one can conclusively say that the initial settlement of Otuoke and its environs and the subsequent infrastructural development was influenced by the underlying near surface geology (rigid earth), among other factors.

Keywords: geology, seismic, infrastructural, near-surface

Procedia PDF Downloads 267
1081 Chromite Exploration Using Electrical Resistivity Tomography in Ingessana Hill, Blue Nile State, Sudan

Authors: Mohamed A. Mohamed-Ali, Jannis Simos, Khalid M. Kheiralla

Abstract:

The Ingessana hills in the southern Blue Nile of Sudan are part of the southern sector of the NE-SW trending ophiolithic belt of the Arab-Nubian Shield with mid-neoproterozoic age. The rocks are mainly serpentinized and in parts highly silicified dunites especially towards the contact with the intruding Bau granite. A promising chromite mineralization zones in the area tend to be generally associated with NE-SW trending shear-zones. A detailed geophysical survey employing electrical resistivity tomography (ERT) at 34 lines were carried out over a zone of a known chromite mineralization to test feasibility of detecting and delineating the ore (if exist) and accordingly facilitate the positioning of exploratory drill holes. ERT sections were inverted with smooth constraints inversion code where the contacts between the granite and the ultramafics are showing up clearly. The continuity of mineralization along the contact is not well confirmed. However, the low-resistivity anomalies are probably recognized as potential chromite mineralization zones. These anomalies represent prime targets for further exploration by drilling, trenching or shallow pits. If the results of the drilling or excavations are positive, small open pit exploitations may produce important tonnages of chromite.

Keywords: chromite exploration, ERT, Ingessana Hills, inversion

Procedia PDF Downloads 360
1080 Metastatic Invasive Lobular Cancer Presenting as a Cervical Polyp

Authors: Sally Shepherd, Craig Murphy

Abstract:

Introduction: The uterus or cervix are unusual locations as metastatic sites for cancers. It is further unusual for it to be a site of metastasis, whilst the primary malignancy remains occult. Case Report: A 63-year-old female with three months of altered bowel habits underwent a CT scan of the abdomen and pelvis, revealing a bulky uterus and left ovary, nonspecific colonic thickening, and diffuse peritoneal changes. She underwent colposcopy, which revealed a large endocervical polyp that was excised, revealing strongly hormone-positive metastatic invasive lobular breast cancer. She subsequently underwent a PET scan, which showed moderately diffuse activity in the cervix and left adnexa. Breast examination was unremarkable, and screening mammography, ultrasound, and MRI of the breast did not identify any lesions. Her blood tests revealed a Ca 15-3 of 934, CA-125 of 220, and CEA of 27. She was commenced on letrozole and ribociclib with an improvement in her symptoms. Conclusion: It is rare for occult breast cancer to be established and diagnosed by pelvic imaging and biopsy. Suspicion of uterine or cervical metastasis should be heightened in patients with an active or past history of breast cancer.

Keywords: occult breast cancer, cervical metastasis, invasive lobular carcinoma, metastasis

Procedia PDF Downloads 99
1079 Liquid Biopsy and Screening Biomarkers in Glioma Grading

Authors: Abdullah Abdu Qaseem Shamsan

Abstract:

Background: Gliomas represent the most frequent, heterogeneous group of tumors arising from glial cells, characterized by difficult monitoring, poor prognosis, and fatality. Tissue biopsy is an established procedure for tumor cell sampling that aids diagnosis, tumor grading, and prediction of prognosis. We studied and compared the levels of liquid biopsy markers in patients with different grades of glioma. Also, it tried to establish the potential association between glioma and specific blood groups antigen. Result: 78 patients were identified, among whom maximum percentage with glioblastoma possessed blood group O+ (53.8%). The second highest frequency had blood group A+ (20.4%), followed by B+ (9.0%) and A- (5.1%), and least with O-. Liquid biopsy biomarkers comprised of ALT, LDH, lymphocytes, Urea, Alkaline phosphatase, AST Neutrophils, and CRP. The levels of all the components increased significantly with the severity of glioma, with maximum levels seen in glioblastoma (grade IV), followed by grade III and grade II respectively. Conclusion: Gliomas possess significant clinical challenges due to their progression with heterogeneous nature and aggressive behavior. Liquid biopsy is a non-invasive approach which aids to establish the status of the patient and determine the tumor grade, therefore may show diagnostic and prognostic utility. Additionally, our study provides evidence to demonstrate the role of ABO blood group antigens in the development of glioma. However, future clinical research on liquid biopsy will improve the sensitivity and specificity of these tests and validate their clinical usefulness to guide treatment approaches.

Keywords: GBM: glioblastoma multiforme, CT: computed tomography, MRI: magnetic resonance imaging, ctRNA: circulating tumor RNA

Procedia PDF Downloads 11
1078 Laparoscopic Management of Cysts Mimicking Hepatic Cystic Echinococcosis in Children (A Case Series)

Authors: Assia Haif, Djelloul Achouri, Zineddine Soualili

Abstract:

Introduction: Laparoscopic treatment of liver echinococcosis cyst has become popular. In parallel, the diagnostic approach of cystic liver lesions is based on the number of lesions and their distribution. The etiologies of cystic masses in children are different, and the role of imaging in their characterization and pre-therapeutic evaluation is essential. The main differential diagnoses of hepatic hydatid cysts can be discovered intraoperatively by minimally invasive surgery. Methods: The clinical data contained seven patients with hepatic cystic who underwent laparoscopic surgery in the Department of Pediatric Surgery, SETIF, Algeria, from 2015 to 2022. Results: Of reported seven patients, five are male, and the remaining two are female. Abdominal pain was the most frequent clinical signs. Biological parameters were within normal limits, Abdominal ultrasound, practiced in all cases, completed by abdominal computed tomography (CT), showed a hydatid cystic. For all patients, surgical procedures were performed under laparoscopy. Total cystectomy in four patients, fenestration or subtotal cystectomy in three patients, respectively. A histopathological feature confirmed the nature of the cysts. During the follow-up period, there was no recurrence. Conclusions: Laparoscopic liver surgery is a safe and effective approach, it is an alternative to conventional surgery and a reproducible method. Laparoscopic surgery approach should follow the same principals with those of open surgery. This surgical technique can rectify the diagnosis of hydatid cyst, the histopathological examination confirms the nature of the cystic lesion.

Keywords: children, cyst, echinococcosis, laparoscopic, liver

Procedia PDF Downloads 114
1077 The Budget Impact of the DISCERN™ Diagnostic Test for Alzheimer’s Disease in the United States

Authors: Frederick Huie, Lauren Fusfeld, William Burchenal, Scott Howell, Alyssa McVey, Thomas F. Goss

Abstract:

Alzheimer’s Disease (AD) is a degenerative brain disease characterized by memory loss and cognitive decline that presents a substantial economic burden for patients and health insurers in the US. This study evaluates the payer budget impact of the DISCERN™ test in the diagnosis and management of patients with symptoms of dementia evaluated for AD. DISCERN™ comprises three assays that assess critical factors related to AD that regulate memory, formation of synaptic connections among neurons, and levels of amyloid plaques and neurofibrillary tangles in the brain and can provide a quicker, more accurate diagnosis than tests in the current diagnostic pathway (CDP). An Excel-based model with a three-year horizon was developed to assess the budget impact of DISCERN™ compared with CDP in a Medicare Advantage plan with 1M beneficiaries. Model parameters were identified through a literature review and were verified through consultation with clinicians experienced in diagnosis and management of AD. The model assesses direct medical costs/savings for patients based on the following categories: •Diagnosis: costs of diagnosis using DISCERN™ and CDP. •False Negative (FN) diagnosis: incremental cost of care avoidable with a correct AD diagnosis and appropriately directed medication. •True Positive (TP) diagnosis: AD medication costs; cost from a later TP diagnosis with the CDP versus DISCERN™ in the year of diagnosis, and savings from the delay in AD progression due to appropriate AD medication in patients who are correctly diagnosed after a FN diagnosis.•False Positive (FP) diagnosis: cost of AD medication for patients who do not have AD. A one-way sensitivity analysis was conducted to assess the effect of varying key clinical and cost parameters ±10%. An additional scenario analysis was developed to evaluate the impact of individual inputs. In the base scenario, DISCERN™ is estimated to decrease costs by $4.75M over three years, equating to approximately $63.11 saved per test per year for a cohort followed over three years. While the diagnosis cost is higher with DISCERN™ than with CDP modalities, this cost is offset by the higher overall costs associated with CDP due to the longer time needed to receive a TP diagnosis and the larger number of patients who receive a FN diagnosis and progress more rapidly than if they had received appropriate AD medication. The sensitivity analysis shows that the three parameters with the greatest impact on savings are: reduced sensitivity of DISCERN™, improved sensitivity of the CDP, and a reduction in the percentage of disease progression that is avoided with appropriate AD medication. A scenario analysis in which DISCERN™ reduces the utilization for patients of computed tomography from 21% in the base case to 16%, magnetic resonance imaging from 37% to 27% and cerebrospinal fluid biomarker testing, positive emission tomography, electroencephalograms, and polysomnography testing from 4%, 5%, 10%, and 8%, respectively, in the base case to 0%, results in an overall three-year net savings of $14.5M. DISCERN™ improves the rate of accurate, definitive diagnosis of AD earlier in the disease and may generate savings for Medicare Advantage plans.

Keywords: Alzheimer’s disease, budget, dementia, diagnosis.

Procedia PDF Downloads 119
1076 Alternate Optical Coherence Tomography Technologies in Use for Corneal Diseases Diagnosis in Dogs and Cats

Authors: U. E. Mochalova, A. V. Demeneva, Shilkin A. G., J. Yu. Artiushina

Abstract:

Objective. In medical ophthalmology OCT has been actively used in the last decade. It is a modern non-invasive method of high-precision hardware examination, which gives a detailed cross-sectional image of eye tissues structure with a high level of resolution, which provides in vivo morphological information at the microscopic level about corneal tissue, structures of the anterior segment, retina and optic nerve. The purpose of this study was to explore the possibility of using the OCT technology in complex ophthalmological examination in dogs and cats, to characterize the revealed pathological structural changes in corneal tissue in cats and dogs with some of the most common corneal diseases. Procedures. Optical coherence tomography of the cornea was performed in 112 animals: 68 dogs and 44 cats. In total, 224 eyes were examined. Pathologies of the organ of vision included: dystrophy and degeneration of the cornea, endothelial corneal dystrophy, dry eye syndrome, chronic superficial vascular keratitis, pigmented keratitis, corneal erosion, ulcerative stromal keratitis, corneal sequestration, chronic glaucoma and also postoperative period after performed keratoplasty. When performing OCT, we used certified medical devices: "Huvitz HOCT-1/1F», «Optovue iVue 80» and "SOCT Copernicus Revo (60)". Results. The results of a clinical study on the use of optical coherence tomography (OCT)of the cornea in cats and dogs, performed by the authors of the article in the complex diagnosis of keratopathies of variousorigins: endothelial corneal dystrophy, pigmented keratitis, chronic keratoconjunctivitis, chronic herpetic keratitis, ulcerative keratitis, traumatic corneal damage, sequestration of the cornea of cats, chronic keratitis, complicating the course of glaucoma. The characteristics of the OCT scans are givencorneas of cats and dogs that do not have corneal pathologies. OCT scans of various corneal pathologies in dogs and cats with a description of the revealed pathological changes are presented. Of great clinical interest are the data obtained during OCT of the cornea of animals undergoing keratoplasty operations using various forms of grafts. Conclusions. OCT makes it possible to assess the thickness and pathological structural changes of the corneal surface epithelium, corneal stroma and descemet membrane. We can measure them, determine the exact localization, and record pathological changes. Clinical observation of the dynamics of the pathological process in the cornea using OCT makes it possible to evaluate the effectiveness of drug treatment. In case of negative dynamics of corneal disease, it is necessary to determine the indications for surgical treatment (to assess the thickness of the cornea, the localization of its thinning zones, to characterize the depth and area of pathological changes). According to the OCT of the cornea, it is possible to choose the optimal surgical treatment for the patient, the technique and depth of optically constructive surgery (penetrating or anterior lamellar keratoplasty).; determine the depth and diameter of the planned microsurgical trepanation of corneal tissue, which will ensure good adaptation of the edges of the donor material.

Keywords: optical coherence tomography, corneal sequestration, optical coherence tomography of the cornea, corneal transplantation, cat, dog

Procedia PDF Downloads 38
1075 Early Diagnosis of Alzheimer's Disease Using a Combination of Images Processing and Brain Signals

Authors: E. Irankhah, M. Zarif, E. Mazrooei Rad, K. Ghandehari

Abstract:

Alzheimer's prevalence is on the rise, and the disease comes with problems like cessation of treatment, high cost of treatment, and the lack of early detection methods. The pathology of this disease causes the formation of protein deposits in the brain of patients called plaque amyloid. Generally, the diagnosis of this disease is done by performing tests such as a cerebrospinal fluid, CT scan, MRI, and spinal cord fluid testing, or mental testing tests and eye tracing tests. In this paper, we tried to use the Medial Temporal Atrophy (MTA) method and the Leave One Out (LOO) cycle to extract the statistical properties of the three Fz, Pz, and Cz channels of ERP signals for early diagnosis of this disease. In the process of CT scan images, the accuracy of the results is 81% for the healthy person and 88% for the severe patient. After the process of ERP signaling, the accuracy of the results for a healthy person in the delta band in the Cz channel is 81% and in the alpha band the Pz channel is 90%. In the results obtained from the signal processing, the results of the severe patient in the delta band of the Cz channel were 89% and in the alpha band Pz channel 92%.

Keywords: Alzheimer's disease, image and signal processing, LOO cycle, medial temporal atrophy

Procedia PDF Downloads 165
1074 Influence of Low and Extreme Heat Fluxes on Thermal Degradation of Carbon Fibre-Reinforced Polymers

Authors: Johannes Bibinger, Sebastian Eibl, Hans-Joachim Gudladt

Abstract:

This study considers the influence of different irradiation scenarios on the thermal degradation of carbon fiber-reinforced polymers (CFRP). Real threats are simulated, such as fires with long-lasting low heat fluxes and nuclear heat flashes with short-lasting high heat fluxes. For this purpose, coated and uncoated quasi-isotropic samples of the commercially available CFRP HexPly® 8552/IM7 are thermally irradiated from one side by a cone calorimeter and a xenon short-arc lamp with heat fluxes between 5 and 175 W/cm² at varying time intervals. The specimen temperature is recorded on the front and backside as well as at different laminate depths. The CFRP is non-destructively tested with ultrasonic testing, infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), and micro-focused computed X-Ray tomography (μCT). Destructive tests are performed to evaluate the mechanical properties in terms of interlaminar shear strength (ILSS), compressive and tensile strength. The irradiation scenarios vary significantly in heat flux and exposure time. Thus, different heating rates, radiation effects, and temperature distributions occur. This leads to unequal decomposition processes, which affect the sensitivity of the strength type and damage behaviour of the specimens. However, with the use of surface coatings, thermal degradation of composite materials can be delayed.

Keywords: CFRP, one-sided thermal damage, high heat flux, heating rate, non-destructive and destructive testing

Procedia PDF Downloads 82
1073 Optimization of Temperature Difference Formula at Thermoacoustic Cryocooler Stack with Genetic Algorithm

Authors: H. Afsari, H. Shokouhmand

Abstract:

When stack is placed in a thermoacoustic resonator in a cryocooler, one extremity of the stack heats up while the other cools down due to the thermoacoustic effect. In the present, with expression a formula by linear theory, will see this temperature difference depends on what factors. The computed temperature difference is compared to the one predicted by the formula. These discrepancies can not be attributed to non-linear effects, rather they exist because of thermal effects. Two correction factors are introduced for close up results among linear theory and computed and use these correction factors to modified linear theory. In fact, this formula, is optimized by GA (Genetic Algorithm). Finally, results are shown at different Mach numbers and stack location in resonator.

Keywords: heat transfer, thermoacoustic cryocooler, stack, resonator, mach number, genetic algorithm

Procedia PDF Downloads 341
1072 Segmenting 3D Optical Coherence Tomography Images Using a Kalman Filter

Authors: Deniz Guven, Wil Ward, Jinming Duan, Li Bai

Abstract:

Over the past two decades or so, Optical Coherence Tomography (OCT) has been used to diagnose retina and optic nerve diseases. The retinal nerve fibre layer, for example, is a powerful diagnostic marker for detecting and staging glaucoma. With the advances in optical imaging hardware, the adoption of OCT is now commonplace in clinics. More and more OCT images are being generated, and for these OCT images to have clinical applicability, accurate automated OCT image segmentation software is needed. Oct image segmentation is still an active research area, as OCT images are inherently noisy, with the multiplicative speckling noise. Simple edge detection algorithms are unsuitable for detecting retinal layer boundaries in OCT images. Intensity fluctuation, motion artefact, and the presence of blood vessels also decrease further OCT image quality. In this paper, we introduce a new method for segmenting three-dimensional (3D) OCT images. This involves the use of a Kalman filter, which is commonly used in computer vision for object tracking. The Kalman filter is applied to the 3D OCT image volume to track the retinal layer boundaries through the slices within the volume and thus segmenting the 3D image. Specifically, after some pre-processing of the OCT images, points on the retinal layer boundaries in the first image are identified, and curve fitting is applied to them such that the layer boundaries can be represented by the coefficients of the curve equations. These coefficients then form the state space for the Kalman Filter. The filter then produces an optimal estimate of the current state of the system by updating its previous state using the measurements available in the form of a feedback control loop. The results show that the algorithm can be used to segment the retinal layers in OCT images. One of the limitations of the current algorithm is that the curve representation of the retinal layer boundary does not work well when the layer boundary is split into two, e.g., at the optic nerve, the layer boundary split into two. This maybe resolved by using a different approach to representing the boundaries, such as b-splines or level sets. The use of a Kalman filter shows promise to developing accurate and effective 3D OCT segmentation methods.

Keywords: optical coherence tomography, image segmentation, Kalman filter, object tracking

Procedia PDF Downloads 455
1071 An Improved Method to Compute Sparse Graphs for Traveling Salesman Problem

Authors: Y. Wang

Abstract:

The Traveling salesman problem (TSP) is NP-hard in combinatorial optimization. The research shows the algorithms for TSP on the sparse graphs have the shorter computation time than those for TSP according to the complete graphs. We present an improved iterative algorithm to compute the sparse graphs for TSP by frequency graphs computed with frequency quadrilaterals. The iterative algorithm is enhanced by adjusting two parameters of the algorithm. The computation time of the algorithm is O(CNmaxn2) where C is the iterations, Nmax is the maximum number of frequency quadrilaterals containing each edge and n is the scale of TSP. The experimental results showed the computed sparse graphs generally have less than 5n edges for most of these Euclidean instances. Moreover, the maximum degree and minimum degree of the vertices in the sparse graphs do not have much difference. Thus, the computation time of the methods to resolve the TSP on these sparse graphs will be greatly reduced.

Keywords: frequency quadrilateral, iterative algorithm, sparse graph, traveling salesman problem

Procedia PDF Downloads 198
1070 Development of a Shape Based Estimation Technology Using Terrestrial Laser Scanning

Authors: Gichun Cha, Byoungjoon Yu, Jihwan Park, Minsoo Park, Junghyun Im, Sehwan Park, Sujung Sin, Seunghee Park

Abstract:

The goal of this research is to estimate a structural shape change using terrestrial laser scanning. This study proceeds with development of data reduction and shape change estimation algorithm for large-capacity scan data. The point cloud of scan data was converted to voxel and sampled. Technique of shape estimation is studied to detect changes in structure patterns, such as skyscrapers, bridges, and tunnels based on large point cloud data. The point cloud analysis applies the octree data structure to speed up the post-processing process for change detection. The point cloud data is the relative representative value of shape information, and it used as a model for detecting point cloud changes in a data structure. Shape estimation model is to develop a technology that can detect not only normal but also immediate structural changes in the event of disasters such as earthquakes, typhoons, and fires, thereby preventing major accidents caused by aging and disasters. The study will be expected to improve the efficiency of structural health monitoring and maintenance.

Keywords: terrestrial laser scanning, point cloud, shape information model, displacement measurement

Procedia PDF Downloads 205
1069 Measuring the Effect of Continuous Performance Test-3 Administration on Regional Cerebral Blood Flow with Single-Photon Emission Computed Tomography in Adult ADHD

Authors: Claire Stafford, Charles Golden, Daniel Amen, Kristen Willeumier

Abstract:

The aim of this study is to investigate the effect of the administration of the Conners Continuous Performance Test (CPT-3) on cerebral blood flow (CBF) in adults with ADHD. The data for this study was derived from a large SPECT database. Participants in the ADHD group (n=81, Mage=37.97) were similar to those in the healthy control group (n=8503, Mage=41.86). All participants were assessed for cerebral blood flow levels before and after CPT-3 administration. Both age and gender were considered covariates. Multiple 2-by-2 ANCOVAs with repeated measures were conducted with sphericity assumed. The main effects of CPT-3 administration on CBF levels were significant in the left and right side of the frontal and occipital, and right temporal lobe. The main effects of ADHD diagnosis were significant in all brain areas assessed. The interaction between CPT-3 administration and ADHD diagnosis was significant in the left and right side of the limbic system, basal ganglia, the frontal lobe, and occipital lobe. Post hoc tests with a Bonferroni adjustment revealed that CBF levels increased following CPT-3 administration but less so in the ADHD group. Individuals had higher levels of CBF following the administration of CPT-3. Due to a significant interaction, we can infer that ADHD diagnosis changes the effect of CPT-3 administration on CBF levels. This is consistent with our hypothesis considering that CPT-3 is a test of sustained attention, a common challenge for children with ADHD. The aforementioned interaction was not found to be significant in the parietal lobe. This may be due to the nature of CPT- 3 which does not require an integration of sensory information.

Keywords: SPECT, ADHD, conners continuous performance test, cerebral blood flow

Procedia PDF Downloads 76
1068 Providing a Secure, Reliable and Decentralized Document Management Solution Using Blockchain by a Virtual Identity Card

Authors: Meet Shah, Ankita Aditya, Dhruv Bindra, V. S. Omkar, Aashruti Seervi

Abstract:

In today's world, we need documents everywhere for a smooth workflow in the identification process or any other security aspects. The current system and techniques which are used for identification need one thing, that is ‘proof of existence’, which involves valid documents, for example, educational, financial, etc. The main issue with the current identity access management system and digital identification process is that the system is centralized in their network, which makes it inefficient. The paper presents the system which resolves all these cited issues. It is based on ‘blockchain’ technology, which is a 'decentralized system'. It allows transactions in a decentralized and immutable manner. The primary notion of the model is to ‘have everything with nothing’. It involves inter-linking required documents of a person with a single identity card so that a person can go anywhere without having the required documents with him/her. The person just needs to be physically present at a place wherein documents are necessary, and using a fingerprint impression and an iris scan print, the rest of the verification will progress. Furthermore, some technical overheads and advancements are listed. This paper also aims to layout its far-vision scenario of blockchain and its impact on future trends.

Keywords: blockchain, decentralized system, fingerprint impression, identity management, iris scan

Procedia PDF Downloads 104
1067 The Correlation between Three-Dimensional Implant Positions and Esthetic Outcomes of Single-Tooth Implant Restoration

Authors: Pongsakorn Komutpol, Pravej Serichetaphongse, Soontra Panmekiate, Atiphan Pimkhaokham

Abstract:

Statement of Problem: The important parameter of esthetic assessment in anterior maxillary implant include pink esthetic of gingiva and white esthetic of restoration. While the 3 dimensional (3D) implant position are recently concerned as a key for succeeding in implant treatment. However, to our knowledge, the authors did not come across any publication that demonstrated the relations of esthetic outcome and 3D implant position. Objectives: To investigate the correlation between positional accuracy of single-tooth implant restoration (STIR) in all 3 dimensions and their esthetic outcomes. Materials and Methods: 17 patients’ data who had a STIR at central incisor with pristine contralateral tooth were included in this study. Intraoral photographs, dental models, and cone beam computed tomography (CBCT) images were retrieved. The esthetic outcome was assessed in accordance with pink esthetic score and white esthetic score (PES/WES). While the number of correct position in each dimension (mesiodistal, labiolingual, apicocoronal) of the implant were evaluated and defined as 'right' or 'wrong' according to ITI consensus conference by one investigator using CBCT data. The different mean score between right and wrong position in all dimensions was analyzed by Mann-Whitney U test with 0.05 was the significant level of the study. Results: The average score of PES/WES was 15.88 ± 1.65 which was considered as clinically acceptable. The average PES/WES score in 1, 2 and 3 right dimension of the implant position were 16.71, 15.75 and 15.17 respectively. None of the implants placed wrongly in all three dimensions. Statistically significant difference of the PES/WES score was found between the implants that placed right in 3 dimensions and 1 dimension (p = 0.041). Conclusion: This study supported the principle of 3D position of implant. The more properly implant was placed, the higher esthetic outcome was found.

Keywords: accuracy, dental implant, esthetic, 3D implant position

Procedia PDF Downloads 152
1066 An Optimized Association Rule Mining Algorithm

Authors: Archana Singh, Jyoti Agarwal, Ajay Rana

Abstract:

Data Mining is an efficient technology to discover patterns in large databases. Association Rule Mining techniques are used to find the correlation between the various item sets in a database, and this co-relation between various item sets are used in decision making and pattern analysis. In recent years, the problem of finding association rules from large datasets has been proposed by many researchers. Various research papers on association rule mining (ARM) are studied and analyzed first to understand the existing algorithms. Apriori algorithm is the basic ARM algorithm, but it requires so many database scans. In DIC algorithm, less amount of database scan is needed but complex data structure lattice is used. The main focus of this paper is to propose a new optimized algorithm (Friendly Algorithm) and compare its performance with the existing algorithms A data set is used to find out frequent itemsets and association rules with the help of existing and proposed (Friendly Algorithm) and it has been observed that the proposed algorithm also finds all the frequent itemsets and essential association rules from databases as compared to existing algorithms in less amount of database scan. In the proposed algorithm, an optimized data structure is used i.e. Graph and Adjacency Matrix.

Keywords: association rules, data mining, dynamic item set counting, FP-growth, friendly algorithm, graph

Procedia PDF Downloads 391
1065 Enhanced Tensor Tomographic Reconstruction: Integrating Absorption, Refraction and Temporal Effects

Authors: Lukas Vierus, Thomas Schuster

Abstract:

A general framework is examined for dynamic tensor field tomography within an inhomogeneous medium characterized by refraction and absorption, treated as an inverse source problem concerning the associated transport equation. Guided by Fermat’s principle, the Riemannian metric within the specified domain is determined by the medium's refractive index. While considerable literature exists on the inverse problem of reconstructing a tensor field from its longitudinal ray transform within a static Euclidean environment, limited inversion formulas and algorithms are available for general Riemannian metrics and time-varying tensor fields. It is established that tensor field tomography, akin to an inverse source problem for a transport equation, persists in dynamic scenarios. Framing dynamic tensor tomography as an inverse source problem embodies a comprehensive perspective within this domain. Ensuring well-defined forward mappings necessitates establishing existence and uniqueness for the underlying transport equations. However, the bilinear forms of the associated weak formulations fail to meet the coercivity condition. Consequently, recourse to viscosity solutions is taken, demonstrating their unique existence within suitable Sobolev spaces (in the static case) and Sobolev-Bochner spaces (in the dynamic case), under a specific assumption restricting variations in the refractive index. Notably, the adjoint problem can also be reformulated as a transport equation, with analogous results regarding uniqueness. Analytical solutions are expressed as integrals over geodesics, facilitating more efficient evaluation of forward and adjoint operators compared to solving partial differential equations. Certainly, here's the revised sentence in English: Numerical experiments are conducted using a Nesterov-accelerated Landweber method, encompassing various fields, absorption coefficients, and refractive indices, thereby illustrating the enhanced reconstruction achieved through this holistic modeling approach.

Keywords: attenuated refractive dynamic ray transform of tensor fields, geodesics, transport equation, viscosity solutions

Procedia PDF Downloads 19
1064 Multi-Modality Imaging of Aggressive Hoof Wall Neoplasia in Two Horses

Authors: Hannah Nagel, Hayley Lang, Albert Sole Guitart, Natasha Lean, Rachel Allavena, Cleide Sprohnie-Barrera, Alex Young

Abstract:

Aggressive neoplasia of the hoof is a rare occurrence in horses and has been only sporadically described in the literature. In the few cases reported intra-hoof wall, aggressive neoplasia has been documented radiographically and has been described with variable imaging characteristics. These include a well-defined osteolytic area, a smoothly outlined semi-circular defect, an extensive draining tract beneath the hoof wall, as well as an additional large area of osteolysis or an extensive central lytic region. A 20-year-old Quarterhorse gelding and a 10-year-old Thoroughbred gelding were both presented for chronic reoccurring lameness in the left forelimb and left hindlimb, respectively. Both of the cases displayed radiographic lesions that have been previously described but also displayed osteoproliferative expansile regions of additional bone formation. Changes associated with hoof neoplasia are often non-specific due to the nature and capacity of bone to react to pathological insult, which is either to proliferate or be absorbed. Both cases depict and describe imaging findings seen on radiography, contrast radiography, computed tomography, and magnetic resonance imaging before reaching a histological diagnosis of malignant melanoma and squamous cell carcinoma. Although aggressive hoof wall neoplasia is rare, there are some imaging features which may raise our index of suspicion for an aggressive hoof wall lesion. This case report documents two horses with similar imaging findings who underwent multiple assessments, surgical interventions, and imaging modalities with a final diagnosis of malignant neoplasia.

Keywords: horse, hoof, imaging, radiography, neoplasia

Procedia PDF Downloads 110
1063 Nonlinear Absorption and Scattering in Wide Band Gap Silver Sulfide Nanoparticles Colloid and Their Effects on the Optical Limiting

Authors: Hoda Aleali, Nastran Mansour, Maryam Mirzaie

Abstract:

In this paper, we study the optical nonlinearities of Silver sulfide (Ag2S) nanostructures dispersed in the Dimethyl sulfoxide (DMSO) under exposure to 532 nm, 15 nanosecond (ns) pulsed laser irradiation. Ultraviolet–visible absorption spectrometry (UV-Vis), X-ray diffraction (XRD), and transmission electron microscopy (TEM) are used to characterize the obtained nanocrystal samples. The band gap energy of colloid is determined by analyzing the UV–Vis absorption spectra of the Ag2S NPs using the band theory of semiconductors. Z-scan technique is used to characterize the optical nonlinear properties of the Ag2S nanoparticles (NPs). Large enhancement of two photon absorption effect is observed with increase in concentration of the Ag2S nanoparticles using open Z-scan measurements in the ns laser regime. The values of the nonlinear absorption coefficients are determined based on the local nonlinear responses including two photon absorption. The observed aperture dependence of the Ag2S NP limiting performance indicates that the nonlinear scattering plays an important role in the limiting action of the sample.The concentration dependence of the optical liming is also investigated. Our results demonstrate that the optical limiting threshold decreases with increasing the silver sulfide NPs in DMSO.

Keywords: nanoscale materials, silver sulfide nanoparticles, nonlinear absorption, nonlinear scattering, optical limiting

Procedia PDF Downloads 364
1062 Lung HRCT Pattern Classification for Cystic Fibrosis Using a Convolutional Neural Network

Authors: Parisa Mansour

Abstract:

Cystic fibrosis (CF) is one of the most common autosomal recessive diseases among whites. It mostly affects the lungs, causing infections and inflammation that account for 90% of deaths in CF patients. Because of this high variability in clinical presentation and organ involvement, investigating treatment responses and evaluating lung changes over time is critical to preventing CF progression. High-resolution computed tomography (HRCT) greatly facilitates the assessment of lung disease progression in CF patients. Recently, artificial intelligence was used to analyze chest CT scans of CF patients. In this paper, we propose a convolutional neural network (CNN) approach to classify CF lung patterns in HRCT images. The proposed network consists of two convolutional layers with 3 × 3 kernels and maximally connected in each layer, followed by two dense layers with 1024 and 10 neurons, respectively. The softmax layer prepares a predicted output probability distribution between classes. This layer has three exits corresponding to the categories of normal (healthy), bronchitis and inflammation. To train and evaluate the network, we constructed a patch-based dataset extracted from more than 1100 lung HRCT slices obtained from 45 CF patients. Comparative evaluation showed the effectiveness of the proposed CNN compared to its close peers. Classification accuracy, average sensitivity and specificity of 93.64%, 93.47% and 96.61% were achieved, indicating the potential of CNNs in analyzing lung CF patterns and monitoring lung health. In addition, the visual features extracted by our proposed method can be useful for automatic measurement and finally evaluation of the severity of CF patterns in lung HRCT images.

Keywords: HRCT, CF, cystic fibrosis, chest CT, artificial intelligence

Procedia PDF Downloads 39
1061 Coherent Optical Tomography Imaging of Epidermal Hyperplasia in Vivo in a Mouse Model of Oxazolone Induced Atopic Dermatitis

Authors: Eric Lacoste

Abstract:

Laboratory animals are currently widely used as a model of human pathologies in dermatology such as atopic dermatitis (AD). These models provide a better understanding of the pathophysiology of this complex and multifactorial disease, the discovery of potential new therapeutic targets and the testing of the efficacy of new therapeutics. However, confirmation of the correct development of AD is mainly based on histology from skin biopsies requiring invasive surgery or euthanasia of the animals, plus slicing and staining protocols. However, there are currently accessible imaging technologies such as Optical Coherence Tomography (OCT), which allows non-invasive visualization of the main histological structures of the skin (like stratum corneum, epidermis, and dermis) and assessment of the dynamics of the pathology or efficacy of new treatments. Briefly, female immunocompetent hairless mice (SKH1 strain) were sensitized and challenged topically on back and ears for about 4 weeks. Back skin and ears thickness were measured using calliper at 3 occasions per week in complement to a macroscopic evaluation of atopic dermatitis lesions on back: erythema, scaling and excoriations scoring. In addition, OCT was performed on the back and ears of animals. OCT allows a virtual in-depth section (tomography) of the imaged organ to be made using a laser, a camera and image processing software allowing fast, non-contact and non-denaturing acquisitions of the explored tissues. To perform the imaging sessions, the animals were anesthetized with isoflurane, placed on a support under the OCT for a total examination time of 5 to 10 minutes. The results show a good correlation of the OCT technique with classical HES histology for skin lesions structures such as hyperkeratosis, epidermal hyperplasia, and dermis thickness. This OCT imaging technique can, therefore, be used in live animals at different times for longitudinal evaluation by repeated measurements of lesions in the same animals, in addition to the classical histological evaluation. Furthermore, this original imaging technique speeds up research protocols, reduces the number of animals and refines the use of the laboratory animal.

Keywords: atopic dermatitis, mouse model, oxzolone model, histology, imaging

Procedia PDF Downloads 109
1060 Hydrodynamics in Wetlands of Brazilian Savanna: Electrical Tomography and Geoprocessing

Authors: Lucas M. Furlan, Cesar A. Moreira, Jepherson F. Sales, Guilherme T. Bueno, Manuel E. Ferreira, Carla V. S. Coelho, Vania Rosolen

Abstract:

Located in the western part of the State of Minas Gerais, Brazil, the study area consists of a savanna environment, represented by sedimentary plateau and a soil cover composed by lateritic and hydromorphic soils - in the latter, occurring the deferruginization and concentration of high-alumina clays, exploited as refractory material. In the hydromorphic topographic depressions (wetlands) the hydropedogical relationships are little known, but it is observed that in times of rainfall, the depressed region behaves like a natural seasonal reservoir - which suggests that the wetlands on the surface of the plateau are places of recharge of the aquifer. The aquifer recharge areas are extremely important for the sustainable social, economic and environmental development of societies. The understanding of hydrodynamics in relation to the functioning of the ferruginous and hydromorphic lateritic soils system in the savanna environment is a subject rarely explored in the literature, especially its understanding through the joint application of geoprocessing by UAV (Unmanned Aerial Vehicle) and electrical tomography. The objective of this work is to understand the hydrogeological dynamics in a wetland (with an area of 426.064 m²), in the Brazilian savanna,as well as the understanding of the subsurface architecture of hydromorphic depressions in relation to the recharge of aquifers. The wetland was compartmentalized in three different regions, according to the geoprocessing. Hydraulic conductivity studies were performed in each of these three portions. Electrical tomography was performed on 9 lines of 80 meters in length and spaced 10 meters apart (direction N45), and a line with 80 meters perpendicular to all others. With the data, it was possible to generate a 3D cube. The integrated analysis showed that the area behaves like a natural seasonal reservoir in the months of greater precipitation (December – 289mm; January – 277,9mm; February – 213,2mm), because the hydraulic conductivity is very low in all areas. In the aerial images, geotag correction of the images was performed, that is, the correction of the coordinates of the images by means of the corrected coordinates of the Positioning by Precision Point of the Brazilian Institute of Geography and Statistics (IBGE-PPP). Later, the orthomosaic and the digital surface model (DSM) were generated, which with specific geoprocessing generated the volume of water that the wetland can contain - 780,922m³ in total, 265,205m³ in the region with intermediate flooding and 49,140m³ in the central region, where a greater accumulation of water was observed. Through the electrical tomography it was possible to identify that up to the depth of 6 meters the water infiltrates vertically in the central region. From the 8 meters depth, the water encounters a more resistive layer and the infiltration begins to occur horizontally - tending to concentrate the recharge of the aquifer to the northeast and southwest of the wetland. The hydrodynamics of the area is complex and has many challenges in its understanding. The next step is to relate hydrodynamics to the evolution of the landscape, with the enrichment of high-alumina clays, and to propose a management model for the seasonal reservoir.

Keywords: electrical tomography, hydropedology, unmanned aerial vehicle, water resources management

Procedia PDF Downloads 115
1059 Endoscopic Treatment of Esophageal Injuries Using Vacuum Therapy

Authors: Murad Gasanov, Shagen Danielyan, Ali Gasanov, Yuri Teterin, Peter Yartsev

Abstract:

Background: Despite the advances made in modern surgery, the treatment of patients with esophageal injuries remains one of the most topical and complex issues. In recent years, high-technology minimally invasive methods, such as endoscopic vacuum therapy (EVT) in the treatment of esophageal injuries. The effectiveness of EVT has been sufficiently studied in case of failure of esophageal anastomoses, however the application of this method in case of mechanical esophageal injuries is limited by a small series of observations, indicating the necessity of additional study. Aim: The aim was to аnalyzed of own experience in the use of endoscopic vacuum therapy (EVT) in a comprehensive examination of patients with esophageal injuries. Methods: We analyzed the results of treatment of 24 patients with mechanical injuries of the esophagus for the period 2019-2021. Complex treatment of patients included the use of minimally invasive technologies, including percutaneous endoscopic gastrostomy (PEG), EVT and video-assisted thoracoscopic debridement. Evaluation of the effectiveness of treatment was carried out using multislice computed tomography (MSCT), endoscopy and laboratory tests. The duration of inpatient treatment and the duration of EVT, the number of system replacements, complications and mortality were taken into account. Result: EVT in patients with mechanical injuries of the esophagus allowed to achieve epithelialization of the esophageal defect in 21 patients (87.5%) in the form of linear scar on the site of perforation or pseudodiverticulum. Complications were noted in 4 patients (16.6%), including bleeding (2) and and esophageal stenosis in the perforation area (2). Lethal outcome was in one observation (4.2%). Conclusion. EVT may be the method of choice in complex treatment in patients with esophageal lesions.

Keywords: esophagus injuries, damage to the esophagus, perforation of the esophagus, spontaneous perforation of the esophagus, mediastinitis, endoscopic vacuum therapy

Procedia PDF Downloads 82
1058 Biophysical Features of Glioma-Derived Extracellular Vesicles as Potential Diagnostic Markers

Authors: Abhimanyu Thakur, Youngjin Lee

Abstract:

Glioma is a lethal brain cancer whose early diagnosis and prognosis are limited due to the dearth of a suitable technique for its early detection. Current approaches, including magnetic resonance imaging (MRI), computed tomography (CT), and invasive biopsy for the diagnosis of this lethal disease, hold several limitations, demanding an alternative method. Recently, extracellular vesicles (EVs) have been used in numerous biomarker studies, majorly exosomes and microvesicles (MVs), which are found in most of the cells and biofluids, including blood, cerebrospinal fluid (CSF), and urine. Remarkably, glioma cells (GMs) release a high number of EVs, which are found to cross the blood-brain-barrier (BBB) and impersonate the constituents of parent GMs including protein, and lncRNA; however, biophysical properties of EVs have not been explored yet as a biomarker for glioma. We isolated EVs from cell culture conditioned medium of GMs and regular primary culture, blood, and urine of wild-type (WT)- and glioma mouse models, and characterized by nano tracking analyzer, transmission electron microscopy, immunogold-EM, and differential light scanning. Next, we measured the biophysical parameters of GMs-EVs by using atomic force microscopy. Further, the functional constituents of EVs were examined by FTIR and Raman spectroscopy. Exosomes and MVs-derived from GMs, blood, and urine showed distinction biophysical parameters (roughness, adhesion force, and stiffness) and different from that of regular primary glial cells, WT-blood, and -urine, which can be attributed to the characteristic functional constituents. Therefore, biophysical features can be potential diagnostic biomarkers for glioma.

Keywords: glioma, extracellular vesicles, exosomes, microvesicles, biophysical properties

Procedia PDF Downloads 121
1057 Non-Destructing Testing of Sandstones from Unconventional Reservoir in Poland with Use of Ultrasonic Pulse Velocity Technique and X-Ray Computed Microtomography

Authors: Michał Maksimczuk, Łukasz Kaczmarek, Tomasz Wejrzanowski

Abstract:

This study concerns high-resolution X-ray computed microtomography (µCT) and ultrasonic pulse analysis of Cambrian sandstones from a borehole located in the Baltic Sea Coast of northern Poland. µCT and ultrasonic technique are non-destructive methods commonly used to determine the internal structure of reservoir rock sample. The spatial resolution of the µCT images obtained was 27 µm, which enabled the author to create accurate 3-D visualizations of structure geometry and to calculate the ratio of pores volume to the total sample volume. A copper X-ray source filter was used to reduce image artifacts. Furthermore, samples Young’s modulus and Poisson ratio were obtained with use of ultrasonic pulse technique. µCT and ultrasonic pulse technique provide complex information which can be used for explorations and characterization of reservoir rocks.

Keywords: elastic parameters, linear absorption coefficient, northern Poland, tight gas

Procedia PDF Downloads 222
1056 A Clinical Study of Tracheobronchopathia Osteochondroplastica: Findings from a Large Chinese Cohort

Authors: Ying Zhu, Ning Wu, Hai-Dong Huang, Yu-Chao Dong, Qin-Ying Sun, Wei Zhang, Qin Wang, Qiang Li

Abstract:

Background and study aims: Tracheobronchopathia osteochondroplastica (TO) is an uncommon disease of the tracheobronchial system that leads to narrowing of the airway lumen from cartilaginous and/or osseous submucosal nodules. The aim of this study is to perform a detailed review of this rare disease in a large cohort of patients with TO proven by fiberoptic bronchoscopy from China. Patients and Methods: Retrospective chart review was performed on 41,600 patients who underwent bronchoscopy in the Department of Respiratory Medicine of Changhai Hospital between January 2005 and December 2012. Cases of TO were identified based on characteristic features during bronchoscopic examination. Results: 22 cases of bronchoscopic TO were identified. Among whom one-half were male and the mean age was 47.45 ±10.91 years old. The most frequent symptoms at presentation were chronic cough (n=14) and increased sputum production (n=10). Radiographic abnormalities were observed in 3/18 patients and findings on computed tomography consistent with TO such as beaded intraluminal calcifications and/or increased luminal thickenings were observed in 18/22 patients. Patients were classified into the following categories based on the severity of bronchoscopic findings: Stage I (n=2), Stage II (n=6) and Stage III(n=14). The result that bronchoscopic improvement was observed in 2 patients administered with inhaled corticosteroids suggested that resolution of this disease is possible. Conclusions: TO is a benign disease with slow progression, which could be roughly divided into 3 stages on the basis of the characteristic endoscopic features and histopathologic findings. Chronic inflammation was thought to be more important than the other existing plausible hypotheses in the course of TO. Inhaled corticosteroids might have some impact on patients at Stage I/II.

Keywords: airway obstruction, bronchoscopy, etiology, Tracheobronchopathia osteochondroplastica (TO), treatment

Procedia PDF Downloads 433
1055 A Finite Element Study of Laminitis in Horses

Authors: Naeim Akbari Shahkhosravi, Reza Kakavand, Helen M. S. Davies, Amin Komeili

Abstract:

Equine locomotion and performance are significantly affected by hoof health. One of the most critical diseases of the hoof is laminitis, which can lead to horse lameness in a severe condition. This disease exhibits the mechanical properties degradation of the laminar junction tissue within the hoof. Therefore, it is essential to investigate the biomechanics of the hoof, focusing specifically on excessive and cumulatively accumulated stresses within the laminar junction tissue. For this aim, the current study generated a novel equine hoof Finite Element (FE) model under dynamic physiological loading conditions and employing a hyperelastic material model. Associated tissues of the equine hoof were segmented from computed tomography scans of an equine forelimb, including the navicular bone, third phalanx, sole, frog, laminar junction, digital cushion, and medial- dorsal- lateral wall areas. The inner tissues were connected based on the hoof anatomy, and the hoof was under a dynamic loading over cyclic strides at the trot. The strain distribution on the hoof wall of the model was compared with the published in vivo strain measurements to validate the model. Then the validated model was used to study the development of laminitis. The ultimate stress tolerated by the laminar junction before rupture was considered as a stress threshold. The tissue damage was simulated through iterative reduction of the tissue’s mechanical properties in the presence of excessive maximum principal stresses. The findings of this investigation revealed how damage initiates from the medial and lateral sides of the tissue and propagates through the hoof dorsal area.

Keywords: horse hoof, laminitis, finite element model, continuous damage

Procedia PDF Downloads 149
1054 Role of Imaging in Predicting the Receptor Positivity Status in Lung Adenocarcinoma: A Chapter in Radiogenomics

Authors: Sonal Sethi, Mukesh Yadav, Abhimanyu Gupta

Abstract:

The upcoming field of radiogenomics has the potential to upgrade the role of imaging in lung cancer management by noninvasive characterization of tumor histology and genetic microenvironment. Receptor positivity like epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK) genotyping are critical in lung adenocarcinoma for treatment. As conventional identification of receptor positivity is an invasive procedure, we analyzed the features on non-invasive computed tomography (CT), which predicts the receptor positivity in lung adenocarcinoma. Retrospectively, we did a comprehensive study from 77 proven lung adenocarcinoma patients with CT images, EGFR and ALK receptor genotyping, and clinical information. Total 22/77 patients were receptor-positive (15 had only EGFR mutation, 6 had ALK mutation, and 1 had both EGFR and ALK mutation). Various morphological characteristics and metastatic distribution on CT were analyzed along with the clinical information. Univariate and multivariable logistic regression analyses were used. On multivariable logistic regression analysis, we found spiculated margin, lymphangitic spread, air bronchogram, pleural effusion, and distant metastasis had a significant predictive value for receptor mutation status. On univariate analysis, air bronchogram and pleural effusion had significant individual predictive value. Conclusions: Receptor positive lung cancer has characteristic imaging features compared with nonreceptor positive lung adenocarcinoma. Since CT is routinely used in lung cancer diagnosis, we can predict the receptor positivity by a noninvasive technique and would follow a more aggressive algorithm for evaluation of distant metastases as well as for the treatment.

Keywords: lung cancer, multidisciplinary cancer care, oncologic imaging, radiobiology

Procedia PDF Downloads 96