Search results for: dose volume histogram
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4053

Search results for: dose volume histogram

3813 Protective Effect of Herniarin on Ionizing Radiation-Induced Impairments in Brain

Authors: Sophio Kalmakhelidze, Eka Shekiladze, Tamar Sanikidze, Mikheil Gogebashvili, Nazi Ivanishvili

Abstract:

Radiation-induced various degrees of brain injury and cognitive impairment have been described after cranial radiotherapy of brain tumors. High doses of ionizing radiation have a severe impact on the central nervous system, resulting in morphological and behavioral impairments. Structures of the limbic system are especially sensitive to radiation exposure. Hence, compounds or drugs that can reduce radiation-induced impairments can be used as promising antioxidants or radioprotectors. In our study Mice whole-body irradiation with 137Cs was performed at a dose rate of 1,1 Gy/min for a total dose of 5 Gy with a “Gamma-capsule-2”. Irradiated mice were treated with Herniarin (20 mg/kg) for five days before irradiation and the same dose was administrated after one hour of irradiation. The immediate and delayed effects of ionizing radiation, as well as, protective effect of Herniarin was evaluated during early and late post-irradiation periods. The results reveal that ionizing radiation (5 Gy) alters the structure of the hippocampus in adult mice during the late post-irradiation period resulting in the decline of memory formation and learning process. Furthermore, Simple Coumarin-Herniarin reveals a radiosensitizing effect reducing morphological and behavioral alterations.

Keywords: ionizing radiation, cognitive impairments, hippocampus, limbic system, Herniarin

Procedia PDF Downloads 73
3812 Open Fields' Dosimetric Verification for a Commercially-Used 3D Treatment Planning System

Authors: Nashaat A. Deiab, Aida Radwan, Mohamed Elnagdy, Mohamed S. Yahiya, Rasha Moustafa

Abstract:

This study is to evaluate and investigate the dosimetric performance of our institution's 3D treatment planning system, Elekta PrecisePLAN, for open 6MV fields including square, rectangular, variation in SSD, centrally blocked, missing tissue, square MLC and MLC shaped fields guided by the recommended QA tests prescribed in AAPM TG53, NCS report 15 test packages, IAEA TRS 430 and ESTRO booklet no.7. The study was performed for Elekta Precise linear accelerator designed for clinical range of 4, 6 and 15 MV photon beams with asymmetric jaws and fully integrated multileaf collimator that enables high conformance to target with sharp field edges. Seven different tests were done applied on solid water equivalent phantom along with 2D array dose detection system, the calculated doses using 3D treatment planning system PrecisePLAN, compared with measured doses to make sure that the dose calculations are accurate for open fields including square, rectangular, variation in SSD, centrally blocked, missing tissue, square MLC and MLC shaped fields. The QA results showed dosimetric accuracy of the TPS for open fields within the specified tolerance limits. However large square (25cm x 25cm) and rectangular fields (20cm x 5cm) some points were out of tolerance in penumbra region (11.38 % and 10.9 %, respectively). For the test of SSD variation, the large field resulted from SSD 125 cm for 10cm x 10cm filed the results recorded an error of 0.2% at the central axis and 1.01% in penumbra. The results yielded differences within the accepted tolerance level as recommended. Large fields showed variations in penumbra. These differences between dose values predicted by the TPS and the measured values at the same point may result from limitations of the dose calculation, uncertainties in the measurement procedure, or fluctuations in the output of the accelerator.

Keywords: quality assurance, dose calculation, 3D treatment planning system, photon beam

Procedia PDF Downloads 517
3811 Correlations between Folate, Homocysteine Levels, and Markers of Brain Atrophy in Elderly Male and Female Rats

Authors: Fatimah A. Alhomaid, Nadia H. Mahmoud, Maha A. Al-Qaraawi

Abstract:

The present study was designed to induce hyperhomocysteinemia (HHcy) in elderly male and female rats. Also,to evaluate, the effect of (HHcy) as a risk factor for cerebrovascular disease and brain atrophy and folate supplementation on serum levels of Hcy, total cholesterol, low density lipoprotein cholesterol (LDLc), high density lipoprotein cholesterol (HDLc), triglycerides, pyridoxal phosphate , folate also, histopathological examination of brain and cerebrovascular vessels In this work 50 male and 50 female elderly albino rats were used and divided into five groups. The first group served as control, the second and third group received two different dose of L-methionine, the fourth and fifth group received fortified diet with folate powder plus L-methionine. Our results showed that homocysteine levels in male and female rats that received low and high dose of methionine were higher than in the control group, while the levels of folate significantly decreased in male rats only. Induced hyperhomocysteinemia in elderly male and female rats led to significant increase in serum level of cholesterol, LDLc and triglycerides but serum level of HDLc were significantly lower in methionine treated male and female rats than in control. Our results showed that a strong positive correlation between all these parameters and homocysteine except HDLc levels which correlate negatively to Hcy levels. Administration of folate to methionine treated male rats led to insignificant changes in the level of cholesterol when compared to control group but this level was found to be significantly decrease in female rats received small dose of methionine. When the level of cholesterol compared to the same dose of methionine treated group we found a significant decrease in both male and female rats. LDLc and triglycerides level significantly decrease in male rats only versus the control rats, while when compared to low and high dose of methionine a significant decreased occurs. A significant increase in serum level of HDLc in male and female rats when compared to both control and methionine treated groups. In male and female rats supplemented with folate we found an increased serum levels of folate when compared to rats received both dose of methionine. The levels of pyridoxal phosphate significantly decreased in all treated rats compared to the control group and its level were increased with supplementation of folate versus the rats received small and large dose of methionine. It can be concluded that hyperhomocysteinemia may be an additional risk factor for cerebrovascular atherosclesosis and brain atrophy in elderly people and diatery supplementation with folate blocking the activity of homocysteine and may be considered as a therapeutic possibility.

Keywords: hyperhomocysteinemia, brain atrophy, cerebrovascular, L-methionine, pyridoxal phosphate

Procedia PDF Downloads 302
3810 Poliovirus Vaccine Immunity among Chronically Malnourished Pakistani Infants: A Randomized Controlled Trial from Developing Country

Authors: Ali Faisal Saleem, Farheen Quadri, Mach Ondrej, Anita Zaidi

Abstract:

Purpose: Pakistan is the final frontier for a polio-free world. Chronic malnutrition is associated with lack of effective gut immunity, and possibly associated with poliomyelitis in children received multiple OPV. We evaluate IPV dose administered together with OPV results in higher immunogenicity and mucosal immunity compared to OPV alone in chronically malnourished infants. Methods AND Materials: A community-based, unblinded-randomized-trial, conducted in 5 peri-urban, low-middle-income households of Karachi, in infants 9-12 months. Two study groups were non-malnourished (HAZ= -2 or more) and chronic malnourished (HAZ <-2SD), with 2-arms each i) OPV and ii) OPV and IPV. Two blood specimens (2ml) at baseline and at day 28 and two stool specimens (6 gm.) at day 29 and after 7 days. All infants received a bOPV challenge dose after first stool specimen. Calculates sample size was 210 in each arm. Serological (baseline compared to 28 days post-vaccine) and mucosal immunity after one week of bOPV challenge dose were study outcomes. Results: Baseline seroprevalence in malnourished infants were low compared to non-malnourished (P1, P2 and P3 (p=<0.001). There is significant rise in antibody titer and P1 seroprevalence in Mal A and B after receiving study vaccine; much higher in Mal B. Infants randomized to bOPV + IPV study vaccine showed incremental immune response against P1 (Mal B, 92.2%; Nor B, 98.4%), P2 (Mal B, 90.4%; Nor B, 94.7%), and P3 (Mal B, 85.6% and Nor B, 93.5%) was observed. A significant proportion of infants in malnourished (P1, 13%; P2, 24%; P3, 26%) and normally nourished group (P1, 5%; P2, 11%; P3, 14%) were found to be seronegative at baseline. Infants who received BOPV + IPV as their study vaccine showed a very high seroconversion response after vaccine (p=<0.001 for P1, P2 and P3). Majority of the specimens were negative at baseline (Mal A, 2%, Mal B, 1%; Nor A, 2%; Nor B, 1%), and remains negative after bOPV challenge dose (Mal A, 8%, Mal B, 6%; Nor A, 11%; Nor B, 10%). Conclusion: Malnourished-infants have low poliovirus-seroprevalence that increased remarkably after IPV. There is less viral shedding after IPV in infants.

Keywords: chronic malnutrition, infants, IPV, OPV

Procedia PDF Downloads 398
3809 Hexavalent Chromium-Induced Changes in Biochemical Parameters of Wistar Albino Rats

Authors: Ounassa Adjroud

Abstract:

Potassium dichromate (K2Cr2O7) is one of the most toxic elements to which man can be exposed at work or in the environment. The purpose of the current work is to compare the effect of K2Cr2O7 using variations in the dose, route of administration and duration of exposure in male and female Wistar albino rats with a special focus on biochemical parameters. K2Cr2O7 was subcutaneously administered alone (10, 50 and 100 mg/kg body weight) to female Wistar albino rats. Male rats received in their drinking water K2Cr2O7 30 mg/L/day) for 20 consecutive days. The Biochemical parameters were evaluated on days 3, 6 and 21 after subcutaneous (sc.) treatment in female rats and on days 10 and 20 after oral administration in male rats. The subcutaneous (s.c.) administration of 25 mg/kg of K2Cr2O7 to Wistar albino rats induced a slight change in plasma glucose levels during the experiment period. On the contrary, a significant decrease in plasma glucose levels was observed with 50 mg/kg mainly on days 3 (-26%) and 21 (-48%) after treatment compared to controls females rats. On the other hand, the higher dose provoked a significant increase in plasma glucose concentrations on days 6 (+31%) and 21 (+60%). similarly, the lower dose of chromium had no effect on the plasma urea levels. Conversely, a significant increase (122%) in this parameter was obtained during the first three days after treatment. In addition, a significant decrease in plasma glucose levels was observed with 50 mg/kg mainly on days 3 (-26%) and 21 (-48%) after treatment. On the other hand, the higher dose provoked a significant increase in plasma glucose concentrations on days 6 (+31%) and 21 (+60%). similarly, the lower dose of chromium had no effect on the plasma urea levels. Conversely, a significant increase in this parameter (122%) was obtained during the first three days after treatment. In addition, administration of 100 mg/kg of K2Cr2O7 by s.c markedly augmented the levels of plasma urea on days 3 (62%) and 6 (121%). Administration of 30 mg/L/day of K2Cr2O7 in the drinking water induced a significant augmentation in both of plasma glucose (27%) and urea (126%) during the first ten days of treatment. These results suggested that K2Cr2O7 administered subcutaneously or in the drinking water may induce harmful effects on biochemical parameters.

Keywords: glucose, potassium dichromate, Wistar albino rat, urea

Procedia PDF Downloads 283
3808 Dosimetry in Interventional Radiology Examinations for Occupational Exposure Monitoring

Authors: Ava Zarif Sanayei, Sedigheh Sina

Abstract:

Interventional radiology (IR) uses imaging guidance, including X-rays and CT scans, to deliver therapy precisely. Most IR procedures are performed under local anesthesia and start with a small needle being inserted through the skin, which may be called pinhole surgery or image-guided surgery. There is increasing concern about radiation exposure during interventional radiology procedures due to procedure complexity. The basic aim of optimizing radiation protection as outlined in ICRP 139, is to strike a balance between image quality and radiation dose while maximizing benefits, ensuring that diagnostic interpretation is satisfactory. This study aims to estimate the equivalent doses to the main trunk of the body for the Interventional radiologist and Superintendent using LiF: Mg, Ti (TLD-100) chips at the IR department of a hospital in Shiraz, Iran. In the initial stage, the dosimeters were calibrated with the use of various phantoms. Afterward, a group of dosimeters was prepared, following which they were used for three months. To measure the personal equivalent dose to the body, three TLD chips were put in a tissue-equivalent batch and used under a protective lead apron. After the completion of the duration, TLDs were read out by a TLD reader. The results revealed that these individuals received equivalent doses of 387.39 and 145.11 µSv, respectively. The findings of this investigation revealed that the total radiation exposure to the staff was less than the annual limit of occupational exposure. However, it's imperative to implement appropriate radiation protection measures. Although the dose received by the interventional radiologist is a bit noticeable, it may be due to the reason for using conventional equipment with over-couch x-ray tubes for interventional procedures. It is therefore important to use dedicated equipment and protective means such as glasses and screens whenever compatible with the intervention when they are available or have them fitted to equipment if they are not present. Based on the results, the placement of staff in an appropriate location led to increasing the dose to the radiologist. Manufacturing and installation of moveable lead curtains with a thickness of 0.25 millimeters can effectively minimize the radiation dose to the body. Providing adequate training on radiation safety principles, particularly for technologists, can be an optimal approach to further decreasing exposure.

Keywords: interventional radiology, personal monitoring, radiation protection, thermoluminescence dosimetry

Procedia PDF Downloads 62
3807 Effect of Acute Dose of Mobile Phone Radiation on Life Cycle ‎of the Mosquito, Culex univittatus

Authors: Fatma H. Galal, Alaaeddeen M. Seufi

Abstract:

Due to the increasing usage of mobile phone, experiments were designed to investigate ‎the effect of acute dose exposure on the mosquito life cycle. 50 tubes (5 ml size) ‎containing 3 ml water and a first instar larva of the mosquito, Culex univittatus were put ‎between two mobile cell phones switched on talking mode for 4 continuous hours. A ‎control group of tubes (unexposed to radiation) were used. Larval and pupal durations ‎were calculated. Furthermore, adult emergence and sex ratio were observed for both ‎treated and control larvae. Results indicated that the employed dose of radiation reduced ‎total larval duration to about half the value of control. 1st, 2nd, 3rd and 4th larval ‎durations were reduced significantly by mobile radiation when compared to controls. ‎Meanwhile pupal duration was elongated significantly by mobile radiation when ‎compared to control. Sex ratio was significantly shifted in favor of females in the case of ‎radiated mosquitoes. Successful adult emergence was decreased significantly in the case ‎of radiated insects when compared to controls. Molecular studies to investigate the ‎effects of mobile radiation on insects and other model organisms are going on.‎

Keywords: mosquito, mobilr radiation, larval and pupal durations, sex ratio

Procedia PDF Downloads 185
3806 Induced Breeding of Neolissochilus hexagonolepis Using Pituitary and Synthetic Hormone under the Agro-Climatic Condition of Meghalaya, India

Authors: Lydia Booney Jyrwa, Rabindra Nath Bhuyan

Abstract:

Chocolate Mahseer (Neolissochilus hexagonolepis) is one of the Mahseer species inhabiting the North-eastern region of India and is a native species to the state of Meghalaya since it can adapt and grow well under the agro climatic conditions of the region. The natural population of this fish has been declining over the years from this part of the country. The natural population of this fish has been declining over the years from this part of the country. The fish is considered as one of the endangered species of the Mahseer group, which is having tremendous scope for culture, sports and tourism. But non-availability of quality seed is a hindrance for the culture of this fish. Thus induced breeding of the fish by hormonal administration with pituitary gland and synthetic hormones is the only reliable method to procure the pure seed of the fish. Chocolate Mahseer was successfully bred at the Hatchery Complex, St. Anthony’s College, Shillong, Meghalaya by using pituitary extract and synthetic hormone viz. ovaprim, ovatide and gonopro-FH. The dose standardized is @ 4mg/kg body weight to both male and female as 1st dose and @ 7.9 mg/kg body weight only to female as 2nd dose for pituitary extract and single dose @ 0.8 ml/kg body weight to female and @ 0.3 ml/kg body weight to male of both ovaprim and ovatide, while a single dose @ 0.9 ml/kg body weight to female and @ 0.3 ml/kg body weight to male of gonopro-FH. The doses are standardized after a series of trial and error experiment performed. The fecundity of the fish was 3500 eggs/ kg body weight. The final hatching percentage achieved was 60%. The survival rate of hatchling was 50% up to fry stage. The use of synthetic hormone and positive response of the fish to the hormone will go in long way for production of quality seed of the fish which in turn help in culture of the species as the fish can be a very good candidate species for the culture in the state. This study will also help in the ranching of the fish in the natural habitat leading to conservation of the species. However, the study should be continued further for the large scale production of seeds.

Keywords: chocolate mahseer, induced breeding, pituitary extract, synthetic hormone

Procedia PDF Downloads 241
3805 Half Dose Tissue Plasminogen Activator for Intermediate-Risk Pulmonary Embolism

Authors: Macie Matta, Ahmad Jabri, Stephanie Jackson

Abstract:

Introduction: In the absence of hypotension, pulmonary embolism (PE) causing right ventricular dysfunction or strain, whether confirmed by imaging or cardiac biomarkers, is deemed to be an intermediate-risk category. Urgent treatment of intermediate-risk PE can prevent progression to hemodynamic instability and death. Management options include thrombolysis, thrombectomy, or systemic anticoagulation. We aim to evaluate the short-term outcomes of a half-dose tissue plasminogen activator (tPA) for the management of intermediate-risk PE. Methods: We retrospectively identified adult patients diagnosed with intermediate-risk PE between the years 2000 and 2021. Demographic data, lab values, imaging, treatment choice, and outcomes were all obtained through chart review. Primary outcomes measured include major bleeding events and in-hospital mortality. Patients on standard systemic anticoagulation without receiving thrombolysis or thrombectomy served as controls. Patient data were analyzed using SAS®️ Software (version 9.4; Cary, NC) to compare individuals that received half-dose tPA with controls, and statistical significance was set at a p-value of 0.05. Results: We included 57 patients in our final analysis, with 19 receiving tPA. Patient characteristics and comorbidities were comparable between both groups. There was a significant difference between PE location, presence of acute deep vein thrombosis, and peak troponin level between both groups. The thrombolytic cohort was more likely to demonstrate a 60/60 sign and thrombus in transit finding on echocardiography than controls. The thrombolytic group was more likely to have major bleeding (17% vs 7.9%, p= 0.4) and in-hospital mortality (5.3% vs 0%, p=0.3); however, this was not statistically significant. Patients who received half-dose tPA had non-significantly higher rates of major bleeding and in-hospital mortality. Larger scale, randomized control trials are needed to establish the benefit and safety of thrombolytics in patients with intermediate-risk PE.

Keywords: pulmonary embolism, half dose thrombolysis, tissue plasminogen activator, cardiac biomarkers, echocardiographic findings, major bleeding event

Procedia PDF Downloads 75
3804 The Nuclear Power Plant Environment Monitoring System through Mobile Units

Authors: P. Tanuska, A. Elias, P. Vazan, B. Zahradnikova

Abstract:

This article describes the information system for measuring and evaluating the dose rate in the environment of nuclear power plants Mochovce and Bohunice in Slovakia. The article presents the results achieved in the implementation of the EU project–Research of monitoring and evaluation of non-standard conditions in the area of nuclear power plants. The objectives included improving the system of acquisition, measuring and evaluating data with mobile and autonomous units applying new knowledge from research. The article provides basic and specific features of the system and compared to the previous version of the system, also new functions.

Keywords: information system, dose rate, mobile devices, nuclear power plant

Procedia PDF Downloads 376
3803 In vivo Antiplatelet Activity Test of Wet Extract of Mimusops elengi L.'s Leaves on DDY Strain Mice as an Effort to Treat Atherosclerosis

Authors: Dewi Tristantini, Jason Jonathan

Abstract:

Coronary Artery Disease (CAD) is one of the deathliest diseases which is caused by atherosclerosis. Atherosclerosis is a disease that plaque builds up inside the arteries. Plaque is made up of fat, cholesterol, calcium, platelet, and other substances found in blood. The current treatment of atherosclerosis is to provide antiplatelet therapy treatment, but such treatments often cause gastrointestinal irritation, muscle pain and hormonal imbalance. Mimusops elengi L.’s leaves can be utilized as a natural and cheap antiplatelet’s source because it contains flavonoids such as quertecin. Antiplatelet aggregation effect of Mimusops elengi L.’s leaves’ wet extract was measured by bleeding time on DDY strain mice with the test substances were given orally during the period of 8 days. The bleeding time was measured on first day and 9th day. Empirically, the dose which is used for humans is 8.5 g of leaves in 600 ml of water. This dose is equivalent to 2.1 g of leaves in 350 ml of water for mice. The extract was divided into 3 doses for mice: 0.05 ml/day; 0.1 ml/day; 0.2 ml/day. After getting the percentage of the increase in bleeding time, data were analyzed by analysis of variance test (Anova), followed by individual comparison within the groups by LSD test. The test substances above respectively increased bleeding time 21%, 62%, and 128%. As the conclusion, the 0.02 ml/day dose of Mimusops elengi L.’s leaves’ wet extract could increase bleeding time better than clopidogrel as positive controls with 110% increase in bleeding time.

Keywords: antiplatelets, atheroschlerosis, bleeding time, Mimusops elengi

Procedia PDF Downloads 264
3802 A Segmentation Method for Grayscale Images Based on the Firefly Algorithm and the Gaussian Mixture Model

Authors: Donatella Giuliani

Abstract:

In this research, we propose an unsupervised grayscale image segmentation method based on a combination of the Firefly Algorithm and the Gaussian Mixture Model. Firstly, the Firefly Algorithm has been applied in a histogram-based research of cluster means. The Firefly Algorithm is a stochastic global optimization technique, centered on the flashing characteristics of fireflies. In this context it has been performed to determine the number of clusters and the related cluster means in a histogram-based segmentation approach. Successively these means are used in the initialization step for the parameter estimation of a Gaussian Mixture Model. The parametric probability density function of a Gaussian Mixture Model is represented as a weighted sum of Gaussian component densities, whose parameters are evaluated applying the iterative Expectation-Maximization technique. The coefficients of the linear super-position of Gaussians can be thought as prior probabilities of each component. Applying the Bayes rule, the posterior probabilities of the grayscale intensities have been evaluated, therefore their maxima are used to assign each pixel to the clusters, according to their gray-level values. The proposed approach appears fairly solid and reliable when applied even to complex grayscale images. The validation has been performed by using different standard measures, more precisely: the Root Mean Square Error (RMSE), the Structural Content (SC), the Normalized Correlation Coefficient (NK) and the Davies-Bouldin (DB) index. The achieved results have strongly confirmed the robustness of this gray scale segmentation method based on a metaheuristic algorithm. Another noteworthy advantage of this methodology is due to the use of maxima of responsibilities for the pixel assignment that implies a consistent reduction of the computational costs.

Keywords: clustering images, firefly algorithm, Gaussian mixture model, meta heuristic algorithm, image segmentation

Procedia PDF Downloads 217
3801 Radiation Risks for Nurses: The Unrecognized Consequences of ERCP Procedures

Authors: Ava Zarif Sanayei, Sedigheh Sina

Abstract:

Despite the advancement of radiation-free interventions in the gastrointestinal and hepatobiliary fields, endoscopy and endoscopic retrograde cholangiopancreatography (ERCP) remain indispensable procedures that necessitate radiation exposure. ERCP, in particular, relies heavily on radiation-guided imaging to ensure precise delivery of therapy. Meanwhile, interventional radiology (IR) procedures also utilize imaging modalities like X-rays and CT scans to guide therapy, often under local anesthesia via small needle insertion. However, the complexity of these procedures raises concerns about radiation exposure to healthcare professionals, including nurses, who play a crucial role in these interventions. This study aims to assess the radiation exposure to the hands and fingers of nurses 1 and 2, who are directly involved in ERCP procedures utilizing (TLD-100) dosimeters at the Gastrointestinal Endoscopy department of a clinic in Shiraz, Iran. The dosimeters were initially calibrated using various phantoms and then a group was prepared and used over a two-month period. For personal equivalent dose measurement, two TLD chips were mounted on a finger ring to monitor exposure to the hands and fingers. Upon completion of the monitoring period, the TLDs were analyzed using a TLD reader, showing that Nurse 1 received an equivalent dose of 298.26 µSv and Nurse 2 received an equivalent dose of 195.39 µSv. The investigation revealed that the total radiation exposure to the nurses did not exceed the annual limit for occupational exposure. Nevertheless, it is essential to prioritize radiation protection measures to prevent potential harm. The study showed that positioning staff members and placing two nurses in a specific location contributed to somehow equal doses. To reduce exposure further, we suggest providing education and training on radiation safety principles, particularly for technologists.

Keywords: dose measurement, ERCP, interventional radiology, medical imaging

Procedia PDF Downloads 34
3800 Risk Assessment of Radiation Hazard for a Typical WWER1000: Cancer Risk Analysis during a Hypothetical Accident

Authors: R. Gharari, N. Kojouri, R. Hosseini Aghdam, E. Alibeigi, B. Salmasian

Abstract:

In this research, the WWER1000/V446 (a PWR Russian type reactor) is chosen as the case study. It is assumed that radioactive materials that release into the environment are more than allowable limit due to a complete failure of the ventilation system (reactor stack). In the following, the HOTSPOT and the RASCAL computational codes have been used and coupled with a developed program using MATLAB software to evaluate Total effective dose equivalent (TEDE) and cancer risk according to the BEIR equations for various human organs. In addition, effects of the containment spray system and climate conditions on the TEDE have been investigated. According to the obtained results, there is an inverse correlation between the received dose and the wind speed; the amount of the TEDE for wind speed 2 m/s and is more than wind speed for 14 m/s during the class A of the climate (2.168 and 0.444 mSv, respectively). Also, containment spray system can effect and reduce the amount of the fission products and TEDE. Furthermore, the probability of the cancer risk for women is more than men, and for children is more than adults. In addition, a specific emergency zonal planning is proposed. Results are promising in which the site selection of the WWER1000/V446 were considered safe for the public in this situation.

Keywords: TEDE, total effective dose equivalent, RASCAL and HOTSPOT codes, BEIR equations, cancer risk

Procedia PDF Downloads 164
3799 Development and Verification of the Idom Shielding Optimization Tool

Authors: Omar Bouhassoun, Cristian Garrido, César Hueso

Abstract:

The radiation shielding design is an optimization problem with multiple -constrained- objective functions (radiation dose, weight, price, etc.) that depend on several parameters (material, thickness, position, etc.). The classical approach for shielding design consists of a brute force trial-and-error process subject to previous designer experience. Therefore, the result is an empirical solution but not optimal, which can degrade the overall performance of the shielding. In order to automate the shielding design procedure, the IDOM Shielding Optimization Tool (ISOT) has been developed. This software combines optimization algorithms with the capabilities to read/write input files, run calculations, as well as parse output files for different radiation transport codes. In the first stage, the software was established to adjust the input files for two well-known Monte Carlo codes (MCNP and Serpent) and optimize the result (weight, volume, price, dose rate) using multi-objective genetic algorithms. Nevertheless, its modular implementation easily allows the inclusion of more radiation transport codes and optimization algorithms. The work related to the development of ISOT and its verification on a simple 3D multi-layer shielding problem using both MCNP and Serpent will be presented. ISOT looks very promising for achieving an optimal solution to complex shielding problems.

Keywords: optimization, shielding, nuclear, genetic algorithm

Procedia PDF Downloads 110
3798 Anti-Implantation Activity of Kepel (Stelechocarpus burahol) Pulp Ethanol Extract in Female Mice

Authors: Suparmi, Israhnanto Isradji, Dina Fatmawati, Iwang Yusuf

Abstract:

Kepel (Stelechocarpus burahol) is one of the traditional plants originating from Indonesia that can be used to prevent pregnancy, launched urine and kidney inflammation. Kepel pulp has compounds alkaloid, triterpenoid, tannin, saponin, and flavonoid, when used will give the hormonal and cytotoxic effect. This study was aimed at evaluating ethanol extract of kepel in vivo for anti-implantation activities. In this experimental study with post test only control group design, 20 female mice were randomly divided into 4 groups. It was divided into the control, the 0,65 mg dose, 1,3 mg dose, and 3,6 mg dose of kepel pulp extract group. The extract soluted in DMSO’s solution and was given 1 ml per mice. The extract was given 10 days before copulation until 18 days of pregnancy. Then, the number of implantation, presence of fetus, and embrio resorbtion were recorded and used to calculate the percentage anti-implantation effect. The results were tested by One-way ANOVA. The mean number of implantation in group control, 0,65 mg;1,3 mg; and 2,6 mg were 5,60±1,14; 6,20± 1,64; 7,60±1,51; 8,00± 1,58, respectively. One way Annova test showed that there is no significant difference in the number of implantation between the group (p > 0,05). The administration of kepel pulp ethanol extract had no effect on the percentage anti-implantation effect and the number of and embrio resorbtion.

Keywords: antiimplantation, fetus, Stelechocarpus burahol, flavonoid

Procedia PDF Downloads 436
3797 Nondestructive Acoustic Microcharacterisation of Gamma Irradiation Effects on Sodium Oxide Borate Glass X2Na2O-X2B2O3 by Acoustic Signature

Authors: Ibrahim Al-Suraihy, Abdellaziz Doghmane, Zahia Hadjoub

Abstract:

We discuss in this work the elastic properties by using acoustic microscopes to measure Rayleigh and longitudinal wave velocities in a no radiated and radiated sodium borate glasses X2Na2O-X2B2O3 with 0 ≤ x ≤ 27 (mol %) at microscopic resolution. The acoustic material signatures were first measured, from which the characteristic surface velocities were determined.Longitudinal and shear ultrasonic velocities were measured in a different composition of sodium borate glass samples before and after irradiation with γ-rays. Results showed that the effect due to increasing sodium oxide content on the ultrasonic velocity appeared more clearly than due to γ-radiation. It was found that as Na2O composition increases, longitudinal velocities vary from 3832 to 5636 m/s in irradiated sample and it vary from 4010 to 5836 m/s in high radiated sample by 10 dose whereas shear velocities vary from 2223 to 3269 m/s in irradiated sample and it vary from 2326 m/s in low radiation to 3385 m/s in high radiated sample by 10 dose. The effect of increasing sodium oxide content on ultrasonic velocity was very clear. The increase of velocity was attributed to the gradual increase in the rigidity of glass and hence strengthening of network due to gradual change of boron atoms from the three-fold to the four-fold coordination of oxygen atoms. The ultrasonic velocities data of glass samples have been used to find the elastic modulus. It was found that ultrasonic velocity, elastic modulus and microhardness increase with increasing barium oxide content and increasing γ-radiation dose.

Keywords: mechanical properties X2Na2O-X2B2O3, acoustic signature, SAW velocities, additives, gamma-radiation dose

Procedia PDF Downloads 396
3796 Pretherapy Initial Dosimetry Results in Prostat Cancer Radionuclide Therapy with Lu-177-PSMA-DOTA-617

Authors: M. Abuqebitah, H. Tanyildizi, N. Yeyin, I. Cavdar, M. Demir, L. Kabasakal

Abstract:

Aim: Targeted radionuclide therapy (TRT) is an increasingly used treatment modality for wide range of cancers. Presently dosimetry is highly required either to plan treatment or to ascertain the absorbed dose delivered to critical organs during treatment. Methods and Materials: The study comprised 7 patients suffered from prostate cancer with progressive disease and candidate to undergo Lu-177-DOTA-617 therapy following to PSMA- PET/CT imaging for all patients. (5.2±0.3 mCi) was intravenously injected. To evaluate bone marrow absorbed dose 2 cc blood samples were withdrawn in short variable times (3, 15, 30, 60, 180 minutes) after injection. Furthermore, whole body scans were performed using scintillation gama camera in 4, 24, 48, and 120 hours after injection and in order to quantify the activity taken up in the body, kidneys , liver, right parotid, and left parotid the geometric mean of anterior and posterior counts were determined through ROI analysis, after that background subtraction and attenuation correction were applied using patients PSMA- PET/CT images taking in a consideration: organ thickness, body thickness, and Hounsfield unites from CT scan. OLINDA/EXM dosimetry program was used for curve fitting, residence time calculation, and absorbed dose calculations. Findings: Absorbed doses of bone marrow, left kidney, right kidney, liver, left parotid, right parotid, total body were 1.28±0.52, 32.36±16.36, 32.7±13.68, 10.35±3.45, 38.67±21.29, 37.55±19.77, 2.25±0.95 (mGy/mCi), respectively. Conclusion: Our first results clarify that Lu-177-DOTA-617 is safe and reliable therapy as there were no complications seen. In the other hand, the observable variation in the absorbed dose of the critical organs among the patients necessitate patient-specific dosimetry approach to save body organs and particularly highly exposed kidneys and parotid gland.

Keywords: Lu-177-PSMA, prostate cancer, radionuclide therapy

Procedia PDF Downloads 480
3795 An Open-Label Phase I Clinical Study: Safety, Tolerability and Pharmacodynamics of Mutant Collagenase Injection in Adults for Localized Fat Reduction

Authors: Yong Cang

Abstract:

RJV001 is a subcutaneous injection containing mutated recombinant Collagenase H (ColH), leading to disruption of collagen matrix in adipose tissue and programmed cell death of adipocytes. Here we reported our clinical investigation of the safety, tolerance and pharmacodynamics of localized RJV001 injection into healthy human abdominal fat tissues (NCT04821648, Arizona Research Center). Investigate the safety, tolerance and clinical pharmacodynamics of subcutaneous RJV001 in humans. In the dose-escalating study, 18 subjects completed the study, 100% female, 78% white, with a mean age of 42[±9.9]. All three tested dose (0.05, 0.075 and 0.15 mg/injection), up to 30 injections, were safe and well-tolerated. Bruising and tenderness to palpation, mild to moderate, were the most frequent local skin reactions but nearly all resolved within 30 days. Additionally, physician-monitored ultrasound measurement showed that a reduction in abdominal fat tissue thickness was consistently observed in Cohort C (0.075, 0.15 mg/injection, 30injections), with a mean reduction of 7.37 [± 2.020] mm. Based on this clinical study, RJV001 has been advanced to phase II clinical studies. In the dose-escalating study, subcutaneously administered RJV001 was safe and well-tolerated in healthy adults up to 0.15 mg/injection, 30 injections. Fat reduction and adipocytolysis were observed by ultrasound measurements and histological analysis for exploratory purposes.

Keywords: fat reduction, mutant collagenase, clinical trial, subcutaneous injection

Procedia PDF Downloads 109
3794 Evaluation of Adequacy of Caspofungin Prescription in a Tunisian Hospital Cohort

Authors: Mariem Meddeb Sidhom, Souhayel Hedfi, Rjaibia Houda, Mehdi Dridi, Mohamed Ali Yousfi, Sâadia Gargouri

Abstract:

Considering the important increase in costs of caspofungin treatments and ahead the evolution of its indication, pharmacy department was prompted to realize a review of the adequacy of prescriptions in the medical intensive care units (ICU). A retrospective observational study was conducted in Tunis military hospital concerning ICU prescriptions of caspofungin from 2008 until 2013. A pharmacist had returned to the patient’s medical records to collect data and to the microbiology department for parasitological results. The adequacy of prescriptions was evaluated by a pharmacist and an infectiologist parasitologist, referring to predefined scale of criteria resuming the indications of the marketing authorization (MA) and grade AI-AII of the guidelines of the Infectious Diseases Society of America (IDSA). Sixty two ICU patients have been treated with caspofungin during the period of study; however, 8 files were lost. Thus, 54 patients were included in the study having received 55 prescriptions of caspofungin. Males were a majority with 64.8% of the population. Mean age was 51 years. Caspofungin was indicated in accordance with the IDSA recommendations in 43.6% of the cases. The most case of non respect to the guidelines was the indication of caspofungin as empirical treatment in non neutropenic patients. Caspofungin was utilized as a first line treatment in 9 cases where it was possible to give fluconazole first, as germs were fluconazole- sensitive. Caspofungin was indicated in 2 patients with good renal function and in which nor amphotericin B, liposomal ampho B neither itraconazole had been previously used, as indicates the MA. The posology of caspofungin was respected in all prescriptions with a loading dose of 70 mg in the first day and a maintenance dose of 50 mg daily. Seven patients had received a daily dose of 70 mg, the recommended dose for people weighing more than 80 Kg. Caspofungin prescriptions are far to be adequately done. There is a clear need of optimization in indicating this molecule and that must be done in collaboration between the pharmacy department, the ICUs and parasitology department.

Keywords: caspofungin, prescription, intensive care units, marketing authorization, Tunisian hospital cohort

Procedia PDF Downloads 339
3793 Hepatoprotective Assessment of L-Ascorbate 1-(2-Hydroxyethyl)-4,6-Dimethyl-1, 2-Dihydropyrimidine-2-on in Toxic Liver Damage Test

Authors: Vladimir Zobov, Nail Nazarov, Alexandra Vyshtakalyuk, Vyacheslav Semenov, Irina Galyametdinova, Vladimir Reznik

Abstract:

The aim of this study was to investigate hepatoprotective properties of the Xymedon derivative L-ascorbate 1- (2-hydroxyethyl)-4,6-dimethyl-1,2-dihydropyrimidine-2-one (XD), which exhibits high efficiency as actoprotector. The study was carried out on 68 male albino rats weighing 250-400 g using preventive exposure to the test preparation. Effectiveness of XD win comparison with effectiveness of Xymedon (original substance) after administration of the compounds in identical doses. Maximum dose was 20 mg/kg. The animals orally received Xymedon or its derivative in doses of 10 and 20 mg/kg over 4 days. In 1-1.5 h after drug administration, CCl4 in vegetable oil (1:1) in a dose of 2 ml/kg. Controls received CCl4 but without hepatoprotectors. Intact control group consisted of rats, not receiving CCl4 or other compounds. The next day after the last administration of CCl4 and compounds under study animals were dehematized under ether anesthesia, blood and liver samples were taken for biochemical and histological analysis. Xymedon and XD administered according to the preventice scheme, exerted hepatoprotective effects: Xymedon — in the dose of 20 mg/kg, XD — in doses of 10 and 20 mg/kg. The drugs under study had different effects on liver condition, affected by induction with CCl4. Xymedon had a more pronounced effect both on the ALT level, which can be elevated not only due to destructive changes in hepatocytes, but also as a cholestasis manifestation, and on the serum total protein level, which reflects protein synthesis in liver. XD had a more pronounced effect on AST level, which is one of the markers of hepatocyte damage. Lower effective dose of XD — 10 mg/kg, compared to Xymedon effective according to, and its pronounced effect on AST, the hepatocyte cytolysis marker, is indicative of its higher preventive effectiveness, compared to Xymedon. This work was performed with the financial support of Russian Science Foundation (grant No: 14-50-00014).

Keywords: hepatoprotectors, pyrimidine derivatives, toxic liver damage, xymedon

Procedia PDF Downloads 302
3792 Environmental Impact Assessment of Ceramic Tile Materials Used in Jordan on Indoor Radon Level

Authors: Mefleh Hamideen

Abstract:

In this investigation, the activity concentrations of ²²⁶Ra, ²³²Th, and ⁴⁰K, of some ceramic tile materials used in the local market of Jordan for interior decoration were determined by making use of High Purity Germanium (HPGe) detector. Twenty samples of the different countries of origin and sizes used in Jordan were analyzed. The concentration values of the last-mentioned radionuclides ranged from 30 Bq.kg⁻¹ (Sample from Jordan) to 98 Bq.kg⁻¹ (Sample from China) for ²²⁶Ra, 31 Bq.kg⁻¹ (Sample from Italy) to 98 Bq.kg⁻¹ (Sample from China) for ²³²Th, and 129 Bq.kg⁻¹ (Sample from Spain) to 679 Bq.kg⁻¹ (Sample from Italy) for ⁴⁰K. Based on the calculated activity concentrations, some radiological parameters have been calculated to test the radiation hazards in the ceramic tiles. In this work, the following parameters: Total absorbed dose rate (DR), Annual effective dose rate (HR), Radium equivalent activity (Raeq), Radon emanation coefficient F (%) and Radon mass exhalation rate (Em) were calculated for all ceramic tiles and listed in the body of the work. Fortunately, the average calculated values of all parameters are less than the recommended values for each parameter. Consequently, almost all the examined ceramic materials appear to have low radon emanation coefficients. As a result of that investigation, no problems on people can appear by using those ceramic tiles in Jordan.

Keywords: radon emanation coefficient, radon mass exhalation rate, total annual effective dose, radon level

Procedia PDF Downloads 201
3791 Reduction of Defects Using Seven Quality Control Tools for Productivity Improvement at Automobile Company

Authors: Abdul Sattar Jamali, Imdad Ali Memon, Maqsood Ahmed Memon

Abstract:

Quality of production near to zero defects is an objective of every manufacturing and service organization. In order to maintain and improve the quality by reduction in defects, Statistical tools are being used by any organizations. There are many statistical tools are available to assess the quality. Keeping in view the importance of many statistical tools, traditional 7QC tools has been used in any manufacturing and automobile Industry. Therefore, the 7QC tools have been successfully applied at one of the Automobile Company Pakistan. Preliminary survey has been done for the implementation of 7QC tool in the assembly line of Automobile Industry. During preliminary survey two inspection points were decided to collect the data, which are Chassis line and trim line. The data for defects at Chassis line and trim line were collected for reduction in defects which ultimately improve productivity. Every 7QC tools has its benefits observed from the results. The flow charts developed for better understanding about inspection point for data collection. The check sheets developed for helps for defects data collection. Histogram represents the severity level of defects. Pareto charts show the cumulative effect of defects. The Cause and Effect diagrams developed for finding the root causes of each defects. Scatter diagram developed the relation of defects increasing or decreasing. The P-Control charts developed for showing out of control points beyond the limits for corrective actions. The successful implementation of 7QC tools at the inspection points at Automobile Industry concluded that the considerable amount of reduction on defects level, as in Chassis line from 132 defects to 13 defects. The total 90% defects were reduced in Chassis Line. In Trim line defects were reduced from 157 defects to 28 defects. The total 82% defects were reduced in Trim Line. As the Automobile Company exercised only few of the 7 QC tools, not fully getting the fruits by the application of 7 QC tools. Therefore, it is suggested the company may need to manage a mechanism for the application of 7 QC tools at every section.

Keywords: check sheet, cause and effect diagram, control chart, histogram

Procedia PDF Downloads 326
3790 Directionally-Sensitive Personal Wearable Radiation Dosimeter

Authors: Hai Huu Le, Paul Junor, Moshi Geso, Graeme O’Keefe

Abstract:

In this paper, the authors propose a personal wearable directionally-sensitive radiation dosimeter using multiple semiconductor CdZnTe detectors. The proposed dosimeter not only measures the real-time dose rate but also provide the direction of the radioactive source. A linear relationship between radioactive source direction and the radiation intensity measured by each detectors is established and an equation to determine the source direction is derived by the authors. The efficiency and accuracy of the proposed dosimeter is verified by simulation using Geant4 package. Results have indicated that in a measurement duration of about 7 seconds, the proposed dosimeter was able to estimate the direction of a 10μCi 137/55Cs radioactive source to within 2 degrees.

Keywords: dose rate, Geant4 package, radiation dosimeter, radioactive source direction

Procedia PDF Downloads 327
3789 Assessment of Reproductive Toxicity of Diazinon Pesticide in Male Wistar Rats

Authors: Mohammad Alfaifi

Abstract:

Organophosphates are among the most widely used synthetic insect pesticides. The widespread use of organophosphates has stimulated research into the possible existence of effects related with their reproductive toxic activity. The present study aimed to assess the effects of diazinon (DIZ) on male reproductive system. DIZ at the dose levels of 1.5, 3.0 and 9.0 mg/kg b. wt./day was administered orally to male rats of Wistar strain for 30 days to evaluate the toxic alterations in testicular histology, biochemistry, sperm dynamics, and testosterone levels. The body weight of animals did not show any significant changes, however, a significant reduction was observed in testes weight. DIZ also brought about marked reduction in epididymal and testicular sperm counts in exposed males and a decrease in serum testosterone concentration. Histopathological examination of testes showed mild to severe degenerative changes in seminiferous tubules at various dose levels. Fertility test showed 79% negative results. All these toxic effects are moderate at low doses and become severe at higher dose levels. From the results of the present study it is concluded that DIZ induces severe testicular damage and results in reduction in sperm count and thus affect fertility. Small changes in sperm counts are known to have adverse affects on human fertility. Therefore, application of such insecticide should be limited to a designed programme.

Keywords: reproductive toxicity, fertility, diazinon, sperm count

Procedia PDF Downloads 318
3788 Mutagenesis, Oxidative Stress Induction and Blood Cytokine Profile in First Generation Male Rats Whose Parents Were Exposed to Radiation and Hexavalent Chromium

Authors: Yerbolat Iztleuov

Abstract:

Stochastic effects, which are currently largely associated with exposure to ionizing radiation or a combination of ionizing radiation with other chemical, physical, and biological agents, are expressed in the form of various mutations. In the first stage of the study, rats of both sexes were divided into 3 groups. 1st - control group, animals of the 2nd group were exposed to gamma radiation at a dose of 0.2 Gy. The third group received hexavalent chromium in a dose of 180 mg/ l with drinking water for a month before irradiation and a day after the end of chromium consumption and was subjected to total gamma irradiation at a dose of 0.2 Gy. The second stage of the experiment. After 3 days, the males were mated with the females. The obtained offspring were studied for peroxidation, cytokine profile and micronucleus in the nuclei. This study shows that 5-month-old offspring whose parents were exposed to combined exposure to chromium and γ-irradiation exhibit hereditary instability of the genome, decreased activity of antioxidant enzymes and sulfhydryl blood groups, and increased levels of lipid peroxidation. There is also an increase in the level of inflammatory markers (IL-6 and TNF) in the blood plasma against the background of a decrease in anti-inflammatory cytokine (IL-10). Thus, the combined effect of hexavalent chromium and ionizing radiation can lead to the development of an oncological process.

Keywords: hexavalent chromium, ionizing radiation, first generation, oxidative stress, cytokines, mutagenesis, cancer

Procedia PDF Downloads 26
3787 Evaluation of Reproductive Toxicity of Diazinon Pesticide in Male Wistar Rats

Authors: Mohammad Alfaifi, Mohammed Alshehri

Abstract:

Organophosphates are among the most widely used synthetic insect pesticides. The widespread use of organophosphates has stimulated research into the possible existence of effects related with their reproductive toxic activity. The present study aimed to assess the effects of diazinon (DIZ) on male reproductive system. DIZ at the dose levels of 1.5, 3.0 and 9.0 mg/kg b. wt./day was administered orally to male rats of Wistar strain for 30 days to evaluate the toxic alterations in testicular histology, biochemistry, sperm dynamics and testosterone levels. The body weight of animals did not show any significant changes; however, a significant reduction was observed in testes weight. DIZ also brought about a marked reduction in epididymal and testicular sperm counts in exposed males and a decrease in serum testosterone concentration. Histopathological examination of testes showed mild to severe degenerative changes in seminiferous tubules at various dose levels. Fertility test showed 79% negative results. All these toxic effects are moderate at low doses and become severe at higher dose levels. From the results of the present study, it is concluded that DIZ induces severe testicular damage and results in a reduction in sperm count and thus affect fertility. Small changes in sperm counts are known to have adverse effects on human fertility. Therefore, application of such insecticide should be limited to a designed programme.

Keywords: organophosphates, reproductive toxicity, diazinon, fertility

Procedia PDF Downloads 411
3786 Preliminary Study of Standardization and Validation of Micronuclei Technique to Assess the DNA Damages Cause for the X-Rays

Authors: L. J. Díaz, M. A. Hernández, A. K. Molina, A. Bermúdez, C. Crane, V. M. Pabón

Abstract:

One of the most important biological indicators that show the exposure to the radiation is the micronuclei (MN). This technique is using to determinate the radiation effects in blood cultures as a biological control and a complement to the physics dosimetry. In Colombia the necessity to apply this analysis has emerged due to the current biological indicator most used is the chromosomal aberrations (CA), that is why it is essential the MN technique’s standardization and validation to have enough tools to improve the radioprotection topic in the country. Besides, this technique will be applied on the construction of a dose-response curve, that allow measure an approximately dose to irradiated people according to MN frequency found. Inside the steps that carried out to accomplish the standardization and validation is the statistic analysis from the lectures of “in vitro” peripheral blood cultures with different analysts, also it was determinate the best culture medium and conditions for the MN can be detected easily.

Keywords: micronuclei, radioprotection, standardization, validation

Procedia PDF Downloads 493
3785 Determination of the Quantity of Water Absorbed by the Plant When Irrigating by Infiltration in Arid Regions (Case of Ouargla in Algeria)

Authors: Mehdi Benlarbi, Dalila Oulhaci

Abstract:

Several physical, human and economic factors come into play in the choice of an irrigation system for developing arid and semi-arid regions. Since it is impossible to define or weight quantitatively all the relevant factors in each case, the choice of the system is often based on subjective preferences rather than explicit analysis. Over the past decade, irrational irrigation in the Ouargla region has evolved to a certain extent based largely on water wastage and which may pose risks to the environment both off-site and at the site. In the whole region, the environment is damaged by excess water because the water tables that tend to be high form swamps that pollute nature on the surface. The purpose of our work is a comparison between sprinkler irrigation and drip irrigation using bottles. By irrigating with the aid of the bottle and giving a volume of 4 liters with a flow rate of one (1) liter per hour, the watering dose received varies between 6 and 7 mm without infiltration losses. And for the case of sprinkler irrigation, the dose received may not exceed 2.5mm. E in some cases, we have a quantity of water lost by infiltration. This shows that irrigation using the bottle is much more efficient than sprinkling. Because, on the one hand, a large amount of water is absorbed by the plant and on the other hand, there is no loss by infiltration. The results obtained are very significant because, on the one hand, we reuse local products, and on the other hand, as the bottles are buried, we avoid water losses by evaporation, especially in dry periods and salinization.

Keywords: resources, water, arid, evaporation, infiltration

Procedia PDF Downloads 76
3784 Toward Indoor and Outdoor Surveillance using an Improved Fast Background Subtraction Algorithm

Authors: El Harraj Abdeslam, Raissouni Naoufal

Abstract:

The detection of moving objects from a video image sequences is very important for object tracking, activity recognition, and behavior understanding in video surveillance. The most used approach for moving objects detection / tracking is background subtraction algorithms. Many approaches have been suggested for background subtraction. But, these are illumination change sensitive and the solutions proposed to bypass this problem are time consuming. In this paper, we propose a robust yet computationally efficient background subtraction approach and, mainly, focus on the ability to detect moving objects on dynamic scenes, for possible applications in complex and restricted access areas monitoring, where moving and motionless persons must be reliably detected. It consists of three main phases, establishing illumination changes in variance, background/foreground modeling and morphological analysis for noise removing. We handle illumination changes using Contrast Limited Histogram Equalization (CLAHE), which limits the intensity of each pixel to user determined maximum. Thus, it mitigates the degradation due to scene illumination changes and improves the visibility of the video signal. Initially, the background and foreground images are extracted from the video sequence. Then, the background and foreground images are separately enhanced by applying CLAHE. In order to form multi-modal backgrounds we model each channel of a pixel as a mixture of K Gaussians (K=5) using Gaussian Mixture Model (GMM). Finally, we post process the resulting binary foreground mask using morphological erosion and dilation transformations to remove possible noise. For experimental test, we used a standard dataset to challenge the efficiency and accuracy of the proposed method on a diverse set of dynamic scenes.

Keywords: video surveillance, background subtraction, contrast limited histogram equalization, illumination invariance, object tracking, object detection, behavior understanding, dynamic scenes

Procedia PDF Downloads 256