24541 Time to CT in Major Trauma in Coffs Harbour Health Campus - The Australian Rural Centre Experience

Authors: Thampi Rawther, Jack Cecire, Andrew Sutherland

Abstract:

Introduction: CT facilitates the diagnosis of potentially life-threatening injuries and facilitates early management. There is evidence that reduced CT acquisition time reduces mortality and length of hospital stay. Currently, there are variable recommendations for ideal timing. Indeed, the NHS standard contract for a major trauma service and STAG both recommend immediate access to CT within a maximum time of 60min and appropriate reporting within 60min of the scan. At Coffs Harbour Health Campus (CHHC), a CT radiographer is on site between 8am-11pm. Aim: To investigate the average time to CT at CHHC and assess for any significant relationship between time to CT and injury severity score (ISS) or time of triage. Method: All major trauma calls between Jan 2021-Oct 2021 were audited (N=87). Patients were excluded if they went from ED to the theatre. Time to CT is defined as the time between triage to the timestamp on the first CT image. Median and interquartile range was used as a measure of central tendency as the data was not normally distributed, and Chi-square test was used to determine association. Results: The median time to CT is 51.5min (IQR 40-74). We found no relationship between time to CT and ISS (P=0.18) and time of triage to time to CT (P=0.35). We compared this to other centres such as John Hunter Hospital and Gold Coast Hospital. We found that the median CT acquisition times were 76min (IQR 52-115) and 43min, respectively. Conclusion: This shows an avenue for improvement given 35% of CT’s were >30min. Furthermore, being proactive and aware of time to CT as an important factor to trauma management can be another avenue for improvement. Based on this, we will re-audit in 12-24months to assess if any improvement has been made.

Keywords: imaging, rural surgery, trauma surgery, improvement

Procedia PDF Downloads 81
24540 Axle Load Estimation of Moving Vehicles Using BWIM Technique

Authors: Changgil Lee, Seunghee Park

Abstract:

Although vehicle driving test for the development of BWIM system is necessary, but it needs much cost and time in addition application of various driving condition. Thus, we need the numerical-simulation method resolving the cost and time problems of vehicle driving test and the way of measuring response of bridge according to the various driving condition. Using the precision analysis model reflecting the dynamic characteristic is contributed to increase accuracy in numerical simulation. In this paper, we conduct a numerical simulation to apply precision analysis model, which reflects the dynamic characteristic of bridge using Bridge Weigh-in-Motion technique and suggest overload vehicle enforcement technology using precision analysis model.

Keywords: bridge weigh-in-motion(BWIM) system, precision analysis model, dynamic characteristic of bridge, numerical simulation

Procedia PDF Downloads 264
24539 A Data Driven Approach for the Degradation of a Lithium-Ion Battery Based on Accelerated Life Test

Authors: Alyaa M. Younes, Nermine Harraz, Mohammad H. Elwany

Abstract:

Lithium ion batteries are currently used for many applications including satellites, electric vehicles and mobile electronics. Their ability to store relatively large amount of energy in a limited space make them most appropriate for critical applications. Evaluation of the life of these batteries and their reliability becomes crucial to the systems they support. Reliability of Li-Ion batteries has been mainly considered based on its lifetime. However, another important factor that can be considered critical in many applications such as in electric vehicles is the cycle duration. The present work presents the results of an experimental investigation on the degradation behavior of a Laptop Li-ion battery (type TKV2V) and the effect of applied load on the battery cycle time. The reliability was evaluated using an accelerated life test. Least squares linear regression with median rank estimation was used to estimate the Weibull distribution parameters needed for the reliability functions estimation. The probability density function, failure rate and reliability function under each of the applied loads were evaluated and compared. An inverse power model is introduced that can predict cycle time at any stress level given.

Keywords: accelerated life test, inverse power law, lithium-ion battery, reliability evaluation, Weibull distribution

Procedia PDF Downloads 147
24538 Effects of an Educational Program on Nurses Knowledge and Practice Related to Hepatitis-B: Pre-Experimental Design

Authors: R. S. Mehta, G. N. Mandal

Abstract:

Hepatitis-B is the major infectious disease of mankind. In Nepal it is reported that more than 4.3% of Nepalese population at any time in their life has been infected with Hepatitis-B virus (HBV). The objective of this study was to evaluate the effectiveness of planned educational programme regarding knowledge and practice of hepatitis-B among the nurses working at medical units of BPKIHS. Pre-experimental research design was used to conduct the study among the nurses working in medical units of BPKIHS. Total 40 nurses were included in the pre-test and 34 in the post-test. The education intervention was arranged on 24th May 2012 from 2:15 pm to 4:45 pm i.e. two and half hours. After two weeks of education intervention post-test was conducted. Most of the participants (60%) were of the age group of 18-22 years, Hindu (82.5%), and unmarried (65%). After education intervention there is significant differences in knowledge on the components of Hepatitis-B at 0.05 level of significance. There is no difference in the attitude components after post-test except the component patient contaminated with Hepatitis-B must be called as the last patient (p=0.035). It can conclude that hepatitis-B educational program improved knowledge and practice among the nurses.

Keywords: educational program, Hepatitis-B, pre-experimental design, medical units

Procedia PDF Downloads 331
24537 Pentax Airway Scope Video Laryngoscope for Orotracheal Intubation in Children: A Randomized Controlled Trial

Authors: In Kyong Yi, Yun Jeong Chae, Jihoon Hwang, Sook-Young Lee, Jong-Yeop Kim

Abstract:

Background: Pentax airway scope (AWS) is a recently developed video laryngoscope for use in both normal and difficult airways, providing a good laryngeal view. The purpose of this randomized noninferior study was to evaluate the efficacy of the Pentax-AWS regarding intubation time, laryngeal view and ease of intubation in pediatric patients with normal airway, compared to Macintosh laryngoscope. Method: A total of 136 pediatric patients aged 1 to 10 with American Society of Anesthesiologists physical status I or II undergoing general anesthesia required orotracheal intubation were randomly allocated into two groups: Macintosh laryngoscope (n =68) and Pentax AWS (n=68). Anesthesia was induced with propofol, rocuronium, and sevoflurane. The primary outcome was intubation time. Cormack-Lehane laryngeal view grade, application of optimal laryngeal external manipulation (OELM), intubation difficulty scale (IDS), intubation failure rate and adverse events were also measured. Result: No significant difference was observed between the two groups regarding intubation time (Macintosh; 23[22-26] sec vs. Pentax; 23.5[22-27.75] sec, p=0.713). As for the laryngeal view grade, the Pentax group showed less number of grade 2a or higher grade cases compared to the Macintosh group (1/2a/2b/3; 52.9%/41.2%/4.4%/1.5% vs. 98.5%/1.5%/0%/0%, p=0.000). No optimal laryngeal external manipulation application was required in the Pentax group (38.2% vs. 0%, p=0.000). Intubation difficulty scale resulted in lower values for Pentax group (0 [0-2] vs. 0 [0-0.55], p=0.001). Failure rate was not different between the two groups (1.5% vs. 4.4%, p=0.619). Adverse event-wise, slightly higher incidence of bleeding (1.5% vs. 5.9%, p=0.172) and teeth injury (0% vs. 5.9%, p=0.042) occurred in the Pentax group. Conclusion: In conclusion, Pentax-AWS provided better laryngeal view, similar intubation time and similar success rate compared with Macintosh laryngoscope in children with normal airway. However, the risk of teeth injury might increase and warrant special attention.

Keywords: Pentax-AWS, pediatric, video laryngoscope, intubation

Procedia PDF Downloads 177
24536 Changes in Postural Stability after Coordination Exercise

Authors: Ivan Struhár, Martin Sebera, Lenka Dovrtělová

Abstract:

The aim of this study was to find out if the special type of exercise with elastic cord can improve the level of postural stability. The exercise programme was conducted twice a week for 3 months. The participants were randomly divided into an experimental group and a control group. The electronic balance board was used for testing of postural stability. All participants trained for 18 hours at the time of experiment without any special form of coordination programme. The experimental group performed 90 minutes plus of coordination exercise. The result showed that differences between pre-test and post-test occurred in the experimental group. It was used the nonparametric Wilcoxon t-test for paired samples (p=0.012; the significance level 95%). We calculated effect size by Cohen´s d. In the experimental group d is 1.96 which indicates a large effect. In the control group d is 0.04 which confirms no significant improvement.

Keywords: balance board, balance training, coordination, stability

Procedia PDF Downloads 369
24535 Validating the Arabic Communicative Development Inventory for Assessing the Development of Language in Arabic-Speaking Children

Authors: Alshaimaa Abdelwahab, Allegra Cattani, Caroline Floccia

Abstract:

Assessing children’s language is fundamental for changing their developmental outcome as it gives a chance for a quick and early intervention with the suitable planning and monitoring program. The importance of language assessment lies in helping to find the right test fit for purpose, in addition to achievement and proficiency. This study examines the validity of a new Arabic assessment tool, the Arabic Communicative Development Inventory ‘Arabic CDI’. It assesses the development of language in Arabic children in different Arabic countries, allowing to detect children with language delay. A concurrent validity is set to compare the Arabic CDI to the Arabic Language test. Twenty-three typically developing Egyptian healthy children and their mothers participated in this study. Their age is 24 months (+ or -) two weeks. The sample included 13 males and 10 females. Mothers completed the Arabic CDI either before or after the Arabic Language Test was conducted with the child. The score for comprehension in the Arabic CDI (M= 52.7, SD= 9.7) and words understood in the Arabic Language Test (M= 59.6, SD= 12.5) were strongly and positively correlated (r= .62, p= .002). At the same time, the scores for production in the Arabic CDI (M= 38.4, SD= 14.8) and words expressed in the Arabic Language Test (M= 52.1, SD= 16.3) were also strongly and positively correlated (r= .82, p= .000). The new Arabic CDI is an adequate tool for assessing the development of comprehension and production at Arabic children. In addition, it could be used for detecting children with language impairment. Standardization of the Arabic CDI across 18 different Arabic dialects in children aged 8 to 30 months is underway.

Keywords: Arabic CDI, assessing children, language development, language impairment

Procedia PDF Downloads 431
24534 Pick and Place System for Dip Glaze Using PID Controller

Authors: Benchalak Muangmeesri

Abstract:

Glazes ceramics are ceramic materials produced through controlled crystallization of a parent glass. The great variety of compositions and the possibility of developing special micro structures with specific technological properties have allowed glass ceramic materials to be used in a wide range of applications. At the same time, glazes ceramics need to improvement in the mechanical and chemical properties of glazed. The pick and place station is equipped with a three-axis module. test piece housings placed on the vacuum are detected module picks up a test piece insert from the slide and places it on the test piece housing. Overall, glazes ceramics are compared with automatically and manually of speed and position control. The handling modules of automatic transfer are a new generation of high speed and precision then these color results from absorption and thickness than manual is also included.

Keywords: glaze, PID control, pick and place, ceramic

Procedia PDF Downloads 353
24533 Analyzing the Relationship between Physical Fitness and Academic Achievement in Chinese High School Students

Authors: Juan Li, Hui Tian, Min Wang

Abstract:

In China, under the considerable pressure of 'Gaokao' –the highly competitive college entrance examination, high school teachers and parents often worry that doing physical activity would take away the students’ precious study time and may have a negative impact on the academic grades. There was a tendency to achieve high academic scores at the cost of physical exercise. Therefore, the purpose of this study was to examine the relationship between the physical fitness and academic achievement of Chinese high school students. The participants were 968 grade one (N=457) and grade two students (N=511) with an average age of 16 years from three high schools of different levels in Beijing, China. 479 were boys, and 489 were girls. One of the schools is a top high school in China, another is a key high school in Beijing, and the other is an ordinary high school. All analyses were weighted using SAS 9.4 to ensure the representatives of the sample. The weights were based on 12 strata of schools, sex, and grades. Physical fitness data were collected using the scores of the National Physical Fitness Test, which is an annual official test administered by the Ministry of Education in China. It includes 50m run, sits and reach test, standing long jump, 1000m run (for boys), 800m run (for girls), pull-ups for 1 minute (for boys), and bent-knee sit-ups for 1 minute (for girls). The test is an overall evaluation of the students’ physical health on the major indexes of strength, endurance, flexibility, and cardiorespiratory function. Academic scores were obtained from the three schools with the students’ consent. The statistical analysis was conducted with SPSS 24. Independent-Samples T-test was used to examine the gender group differences. Spearman’s Rho bivariate correlation was adopted to test for associations between physical test results and academic performance. Statistical significance was set at p<.05. The study found that girls obtained higher fitness scores than boys (p=.000). The girls’ physical fitness test scores were positively associated with the total academic grades (rs=.103, p=.029), English (rs=.096, p=.042), physics (rs=.202, p=.000) and chemistry scores (rs=.131, p=.009). No significant relationship was observed in boys. Cardiorespiratory fitness had a positive association with physics (rs=.196, p=.000) and biology scores (rs=.168, p=.023) in girls, and with English score in boys (rs=.104, p=.029). A possible explanation for the greater association between physical fitness and academic achievement in girls rather than boys was that girls showed stronger motivation in achieving high scores in whether academic tests or fitness tests. More driven by the test results, girls probably tended to invest more time and energy in training for the fitness test. Higher fitness levels were associated with an academic benefit among girls generally in Chinese high schools. Therefore, physical fitness needs to be given greater emphasis among Chinese adolescents and gender differences need to be taken into consideration.

Keywords: physical fitness; adolescents; academic achievement; high school

Procedia PDF Downloads 104
24532 The Use of Electrical Resistivity Measurement, Cracking Test and Ansys Simulation to Predict Concrete Hydration Behavior and Crack Tendency

Authors: Samaila Bawa Muazu

Abstract:

Hydration process, crack potential and setting time of concrete grade C30, C40 and C50 were separately monitored using non-contact electrical resistivity apparatus, a novel plastic ring mould and penetration resistance method respectively. The results show highest resistivity of C30 at the beginning until reaching the acceleration point when C50 accelerated and overtaken the others, and this period corresponds to its final setting time range, from resistivity derivative curve, hydration process can be divided into dissolution, induction, acceleration and deceleration periods, restrained shrinkage crack and setting time tests demonstrated the earliest cracking and setting time of C50, therefore, this method conveniently and rapidly determines the concrete’s crack potential. The highest inflection time (ti), the final setting time (tf) were obtained and used with crack time in coming up with mathematical models for the prediction of concrete’s cracking age for the range being considered. Finally, ANSYS numerical simulations supports the experimental findings in terms of the earliest crack age of C50 and the crack location that, highest stress concentration is always beneath the artificially introduced expansion joint of C50.

Keywords: concrete hydration, electrical resistivity, restrained shrinkage crack, setting time, simulation

Procedia PDF Downloads 187
24531 Infrastructure Change Monitoring Using Multitemporal Multispectral Satellite Images

Authors: U. Datta

Abstract:

The main objective of this study is to find a suitable approach to monitor the land infrastructure growth over a period of time using multispectral satellite images. Bi-temporal change detection method is unable to indicate the continuous change occurring over a long period of time. To achieve this objective, the approach used here estimates a statistical model from series of multispectral image data over a long period of time, assuming there is no considerable change during that time period and then compare it with the multispectral image data obtained at a later time. The change is estimated pixel-wise. Statistical composite hypothesis technique is used for estimating pixel based change detection in a defined region. The generalized likelihood ratio test (GLRT) is used to detect the changed pixel from probabilistic estimated model of the corresponding pixel. The changed pixel is detected assuming that the images have been co-registered prior to estimation. To minimize error due to co-registration, 8-neighborhood pixels around the pixel under test are also considered. The multispectral images from Sentinel-2 and Landsat-8 from 2015 to 2018 are used for this purpose. There are different challenges in this method. First and foremost challenge is to get quite a large number of datasets for multivariate distribution modelling. A large number of images are always discarded due to cloud coverage. Due to imperfect modelling there will be high probability of false alarm. Overall conclusion that can be drawn from this work is that the probabilistic method described in this paper has given some promising results, which need to be pursued further.

Keywords: co-registration, GLRT, infrastructure growth, multispectral, multitemporal, pixel-based change detection

Procedia PDF Downloads 109
24530 Application of Seasonal Autoregressive Integrated Moving Average Model for Forecasting Monthly Flows in Waterval River, South Africa

Authors: Kassahun Birhanu Tadesse, Megersa Olumana Dinka

Abstract:

Reliable future river flow information is basic for planning and management of any river systems. For data scarce river system having only a river flow records like the Waterval River, a univariate time series models are appropriate for river flow forecasting. In this study, a univariate Seasonal Autoregressive Integrated Moving Average (SARIMA) model was applied for forecasting Waterval River flow using GRETL statistical software. Mean monthly river flows from 1960 to 2016 were used for modeling. Different unit root tests and Mann-Kendall trend analysis were performed to test the stationarity of the observed flow time series. The time series was differenced to remove the seasonality. Using the correlogram of seasonally differenced time series, different SARIMA models were identified, their parameters were estimated, and diagnostic check-up of model forecasts was performed using white noise and heteroscedasticity tests. Finally, based on minimum Akaike Information (AIc) and Hannan-Quinn (HQc) criteria, SARIMA (3, 0, 2) x (3, 1, 3)12 was selected as the best model for Waterval River flow forecasting. Therefore, this model can be used to generate future river information for water resources development and management in Waterval River system. SARIMA model can also be used for forecasting other similar univariate time series with seasonality characteristics.

Keywords: heteroscedasticity, stationarity test, trend analysis, validation, white noise

Procedia PDF Downloads 181
24529 Relationships between Screen Time, Internet Addiction and Other Lifestyle Behaviors with Obesity among Secondary School Students in the Turkish Republic of Northern Cyprus

Authors: Ozen Asut, Gulifeiya Abuduxike, Imge Begendi, Mustafa O. Canatan, Merve Colak, Gizem Ozturk, Lara Tasan, Ahmed Waraiet, Songul A. Vaizoglu, Sanda Cali

Abstract:

Obesity among children and adolescents is one of the critical public health problems worldwide. Internet addiction is one of the sedentary behaviors that cause obesity due to the excessive screen time and reduced physical activities. We aimed to examine the relationships between the screen time, internet addiction and other lifestyle behaviors with obesity among high school students in the Near East College in Nicosia, Northern Cyprus. A cross-sectional study conducted among 469 secondary school students, mean age 11.95 (SD, 0.81) years. A self-administrated questionnaire was applied to assess the screen time and lifestyle behaviors. The Turkish adopted version of short-form of internet addiction test was used to assess internet addiction problems. Height and weight were measured to calculate BMI and classified based on the BMI percentiles for sex and age. Descriptive analysis, Chi-Square test, and multivariate regression analysis were done. Of all, 17.2% of the participants were overweight and obese, and 18.1% had internet addictions, while 40.7% of them reported having screen time more than two hours. After adjusting the analysis for age and sex, eating snacks while watching television (OR, 3.04; 95% CI, 1.28-7.21), self- perceived body weight (OR, 24.9; 95% CI, 9.64-64.25) and having a play station in the room (OR, 4.6; 95% CI, 1.85 - 11.42) were significantly associated with obesity. Screen time (OR, 4.68; 95% CI, 2.61-8.38; p=0.000) and having a computer in bedroom (OR, 1.7; 95% CI, 1.01- 2.87; p=0.046) were significantly associated with internet addiction, whereas parent’s compliant regarding the lengthy technology use (OR, 0.23; 95% CI, 0.11-0.46; p=0.000) was found to be a protective factor against internet addiction. Prolonged screen time, internet addiction, sedentary lifestyles, and reduced physical and social activities are interrelated, multi-dimensional factors that lead to obesity among children and adolescents. A family - school-based integrated approach should be implemented to tackle obesity problems.

Keywords: adolescents, internet addiction, lifestyle, Northern Cyprus, obesity, screen time

Procedia PDF Downloads 118
24528 Diagnostics of Subclinical Mastitis in Dairy Cows

Authors: G. Tanbayeva, Z. Myrzabekov, O. Tagayev, B. Barakhov, M. Tokayeva

Abstract:

Mastitis is widely spread among dairy cows bringing large economic damage resulting in decreased milk yield, deterioration of the milk quality, gastrointestinal tract disorders among young animals, culling of breeding stock, and expenses for sick animal treatment. Up-to-date and accurate diagnostics of subclinical (latent) mastitis in dairy cows has huge practical and economical significance. The aim of the research was to develop a new optimal alternative rapid method for the diagnosis of subclinical mastitis in cows. The study was performed in the laboratory of the Hygiene and Sanitation of Kazakh National Agrarian University. The first stage was to evaluate the different percentages of “Promastit” preparation. It showed that the best diagnostics capacity had 10% dilution. The second stage was to compare “Promastit” with some of the domestic and foreign analogues “Somatic-Test” (Denmark), “MastTest” (Russia), “Mastidin” (Ukraine), “Diagmast” (Kazakhstan). The observation was carried out on 520 dairy cows with subclinical mastitis on farms of Almaty region of Kazakhstan. The effectiveness was checked by milk sedimentation test. Our research tends to show that the diagnostic test "Promastitis" revealed subclinical mastitis in 193 out of 520 lactating cows (37.1% of those examined). At the same time, in the case of using other diagnostic tests, the given index was as follows: 35.5% (mastidin), 34.4% (masttest-AF), 33.8% (somatic-test Ecotest), 30.7% (diagmast).

Keywords: dairy cows, diagnostics, subclinical mastitis, test Promastit

Procedia PDF Downloads 332
24527 Graphic Calculator Effectiveness in Biology Teaching and Learning

Authors: Nik Azmah Nik Yusuff, Faridah Hassan Basri, Rosnidar Mansor

Abstract:

The purpose of the study is to find out the effectiveness of using Graphic calculators (GC) with Calculator Based Laboratory 2 (CBL2) in teaching and learning of form four biology for these topics: Nutrition, Respiration and Dynamic Ecosystem. Sixty form four science stream students were the participants of this study. The participants were divided equally into the treatment and control groups. The treatment group used GC with CBL2 during experiments while the control group used the ordinary conventional laboratory apparatus without using GC with CBL2. Instruments in this study were a set of pre-test and post-test and a questionnaire. T-Test was used to compare the student’s biology achievement while a descriptive statistic was used to analyze the outcome of the questionnaire. The findings of this study indicated the use of GC with CBL2 in biology had significant positive effect. The highest mean was 4.43 for item stating the use of GC with CBL2 had saved collecting experiment result’s time. The second highest mean was 4.10 for item stating GC with CBL2 had saved drawing and labelling graphs. The outcome from the questionnaire also showed that GC with CBL2 were easy to use and save time. Thus, teachers should use GC with CBL2 in support of efforts by Malaysia Ministry of Education in encouraging technology-enhanced lessons.

Keywords: biology experiments, Calculator-Based Laboratory 2 (CBL2), graphic calculators, Malaysia Secondary School, teaching/learning

Procedia PDF Downloads 382
24526 Reliability and Validity for Measurement of Body Composition: A Field Method

Authors: Ahmad Hashim, Zarizi Ab Rahman

Abstract:

Measurement of body composition via a field method has the most popular instruments which are used to estimate the percentage of body fat. Among the instruments used are the Body Mass Index, Bio Impedance Analysis and Skinfold Test. All three of these instruments do not involve high costs, do not require high technical skills, are mobile, save time, and are suitable for use in large populations. Because all three instruments can estimate the percentage of body fat, but it is important to identify the most appropriate instruments and have high reliability. Hence, this study was conducted to determine the reliability and convergent validity of the instruments. A total of 40 students, males and females aged between 13 and 14 years participated in this study. The study found that the test retest and Pearson correlation coefficient of reliability for the three instruments is very high, r = .99. While the inter class reliability also are at high level with r = .99 for Body Mass Index and Bio Impedance Analysis, r = .96 for Skin fold test. Intra class reliability coefficient for these three instruments is too high for Body Mass Index r = .99, Bio Impedance Analysis r = .97, and Skin fold Test r = .90. However, Standard Error of Measurement value for all three instruments indicates the Body Mass Index is the most appropriate instrument with a mean value of .000672 compared with other instruments. The findings show that the Body Mass Index is an instrument which is the most accurate and reliable in estimating body fat percentage for the population studied.

Keywords: reliability, validity, body mass index, bio impedance analysis and skinfold test

Procedia PDF Downloads 309
24525 Correlation between the Undrained Shear Strength of Clay of the Champlain Sea as Determined by the Vane Test and the Swedish Cone

Authors: Tahar Ayadat

Abstract:

The undrained shear strength is an essential parameter for determining the consistency and the ultimate bearing capacity of a clay layer. The undrained shear strength can be determined by field tests such as the in situ vane test or in laboratory, including hand vane test, triaxial, simple compression test, and the consistency penetrometer (i.e. Swedish cone). However, the field vane test and the Swedish cone are the most commonly used tests by geotechnical experts. In this technical note, a comparison between the shear strength results obtained by the in situ vane test and the cone penetration test (Swedish cone) was conducted. A correlation between the results of these two tests, concerning the undrained shear strength of the Champlain sea clay, has been developed. Moreover, some applications of the proposed correlation on some geotechnical problems have been included, such as the determination of the consistency and the bearing capacity of a clay layer.

Keywords: correlation, shear strength, clay, vane test, Swedish cone

Procedia PDF Downloads 374
24524 Ankaferd Blood Stopper (ABS) Has Protective Effect on Colonic Inflammation: An in Vitro Study in Raw 264.7 and Caco-2 Cells

Authors: Aysegul Alyamac, Sukru Gulec

Abstract:

Ankaferd Blood Stopper (ABS) is a plant extract used to stop bleeding caused by injuries and surgical interventions. ABS also involved in wound healing of intestinal mucosal damage due to oxidative stress and inflammation. Inflammatory Bowel Disease (IBD) is a common chronic disorder of the gastrointestinal tract that causes abdominal pain, diarrhea, and gastrointestinal bleeding, and increases the risk of colon cancer. Inflammation is an essential factor in the development of IBD. The various studies have been performed about the physiological effects of ABS; however, ABS dependent mechanism on colonic inflammation has not been elucidated. Thus, the protective effect of ABS on colonic inflammation was investigated in this study. The Caco-2 and RAW 264.7 murine macrophage cells were used as a model of in vitro colonic inflammation. RAW 264.7 cells were treated with lipopolysaccharide (LPS) for 12 hours to induce the inflammation, and a conditional medium was obtained. Caco-2 cells were treated with 15 µl/ml ABS for 4 hours, then incubated with conditional medium and the cells also were incubated with 15 µl/ml ABS and conditional medium together for 4 hours. Tumor necrosis factor alpha (TNF-α) protein levels were targeted in testing inflammatory condition and its level was significantly increased (25 fold, p<0.001) compared to the control group by using Enzyme-Linked Immunosorbent Assay (ELISA) method. The COX-2 mRNA level was used as a marker gene to show the possible anti-inflammatory effect of ABS in Caco-2 cells. RAW cells-derived conditional medium significantly (3.3 fold, p<0.001) induced cyclooxygenase-2 (COX-2) mRNA levels in Caco-2 cells. The pretreatment of Caco-2 cells caused a significant decrease (3.3 fold, p<0.001) in COX-2 mRNA levels relative to conditional medium given group. Furthermore, COX-2 mRNA level was significantly reduced (4,7 fold, p<0.001) in ABS and conditional medium treated group. These results suggest that ABS might have an anti-inflammatory effect in vitro.

Keywords: Ankaferd blood stopper, CaCo-2, colonic inflammation, RAW 264.7

Procedia PDF Downloads 115
24523 Hypertensive Response to Maximal Exercise Test in Young and Middle Age Hypertensive on Blood Pressure Lowering Medication: Monotherapy vs. Combination Therapy

Authors: James Patrick A. Diaz, Raul E. Ramboyong

Abstract:

Background: Hypertensive response during maximal exercise test provides important information on the level of blood pressure control and evaluation of treatment. Method: A single center retrospective descriptive study was conducted among 117 young (aged 20 to 40) and middle age (aged 40 to 65) hypertensive patients, who underwent treadmill stress test. Currently on maintenance frontline medication either monotherapy (Angiotensin-converting enzyme inhibitor/Angiotensin receptor blocker [ACEi/ARB], Calcium channel blocker [CCB], Diuretic - Hydrochlorthiazide [HCTZ]) or combination therapy (ARB+CCB, ARB+HCTZ), who attained a maximal exercise on treadmill stress test (TMST) with hypertensive response (systolic blood pressure: male >210 mm Hg, female >190 mm Hg, diastolic blood pressure >100 mmHg, or increase of >10 mm Hg at any time during the test), on Bruce and Modified Bruce protocol. Exaggerated blood pressure response during exercise (systolic [SBP] and diastolic [DBP]), peak exercise blood pressure (SBP and DBP), recovery period (SBP and DBP) and test for ischemia and their antihypertensive medication/s were investigated. Analysis of variance and chi-square test were used for statistical analysis. Results: Hypertensive responses on maximal exercise test were seen mostly among female population (P < 0.000) and middle age (P < 0.000) patients. Exaggerated diastolic blood pressure responses were significantly lower in patients who were taking CCB (P < 0.004). A longer recovery period that showed a delayed decline in SBP was observed in patients taking ARB+HCTZ (P < 0.036). There were no significant differences in the level of exaggerated systolic blood pressure response and during peak exercise (both systolic and diastolic) in patients using either monotherapy or combination antihypertensives. Conclusion: Calcium channel blockers provided lower exaggerated diastolic BP response during maximal exercise test in hypertensive middle age patients. Patients on combination therapy using ARB+HCTZ exhibited a longer recovery period of systolic blood pressure.

Keywords: antihypertensive, exercise test, hypertension, hyperytensive response

Procedia PDF Downloads 254
24522 Virtual Test Model for Qualification of Knee Prosthesis

Authors: K. Zehouani, I. Oldal

Abstract:

Purpose: In the human knee joint, degenerative joint disease may happen with time. The standard treatment of this disease is the total knee replacement through prosthesis implanting. The reason lies in the fact that this phenomenon causes different material abrasion as compare to pure sliding or rolling alone. This study focuses on developing a knee prosthesis geometry, which fulfills the mechanical and kinematical requirements. Method: The MSC ADAMS program is used to describe the rotation of the human knee joint as a function of flexion, and to investigate how the flexion and rotation movement changes between the condyles of a multi-body model of the knee prosthesis as a function of flexion angle (in the functional arc of the knee (20-120º)). Moreover, the multi-body model with identical boundary conditions is constituted, and the numerical simulations are carried out using the MSC ADAMS program system. Results: It is concluded that the use of the multi-body model reduces time and cost since it does not need to manufacture the tibia and the femur as it requires for the knee prosthesis of the test machine. Moreover, without measuring or by dispensing with a test machine for the knee prosthesis geometry, approximation of the results of our model to a human knee is carried out directly. Conclusion: The pattern obtained by the multi-body model provides an insight for future experimental tests related to the rotation and flexion of the knee joint concerning the actual average and friction load.

Keywords: biomechanics, knee joint, rotation, flexion, kinematics, MSC ADAMS

Procedia PDF Downloads 118
24521 Three Dimensional Analysis of Cubesat Thermal Vacuum Test

Authors: Maged Assem Soliman Mossallam

Abstract:

Thermal vacuum testing target is to qualify the space system and ensure its operability under harsh space environment. The functionality of the cubesat was checked at extreme orbit conditions. Test was performed for operational and nonoperational modes. Analysis is done to simulate the cubesat thermal cycling inside thermal vacuum chamber. Comsol Multiphysics finite element is used to solve three dimensional problem for the cubesat inside TVAC. Three dimensional CAD model is done using Autodesk Inventor program. The boundary conditions were applied from the actual shroud temperature. The input heat load variation with time is considered to solve the transient three dimensional problem. Results show that the simulated temperature profiles are within an acceptable range from the real testing data.

Keywords: cubesat, thermal vacuum test, testing simulation, finite element analysis

Procedia PDF Downloads 119
24520 Modification Encryption Time and Permutation in Advanced Encryption Standard Algorithm

Authors: Dalal N. Hammod, Ekhlas K. Gbashi

Abstract:

Today, cryptography is used in many applications to achieve high security in data transmission and in real-time communications. AES has long gained global acceptance and is used for securing sensitive data in various industries but has suffered from slow processing and take a large time to transfer data. This paper suggests a method to enhance Advance Encryption Standard (AES) Algorithm based on time and permutation. The suggested method (MAES) is based on modifying the SubByte and ShiftRrows in the encryption part and modification the InvSubByte and InvShiftRows in the decryption part. After the implementation of the proposal and testing the results, the Modified AES achieved good results in accomplishing the communication with high performance criteria in terms of randomness, encryption time, storage space, and avalanche effects. The proposed method has good randomness to ciphertext because this method passed NIST statistical tests against attacks; also, (MAES) reduced the encryption time by (10 %) than the time of the original AES; therefore, the modified AES is faster than the original AES. Also, the proposed method showed good results in memory utilization where the value is (54.36) for the MAES, but the value for the original AES is (66.23). Also, the avalanche effects used for calculating diffusion property are (52.08%) for the modified AES and (51.82%) percentage for the original AES.

Keywords: modified AES, randomness test, encryption time, avalanche effects

Procedia PDF Downloads 219
24519 Statistically Significant Differences of Carbon Dioxide and Carbon Monoxide Emission in Photocopying Process

Authors: Kiurski S. Jelena, Kecić S. Vesna, Oros B. Ivana

Abstract:

Experimental results confirmed the temporal variation of carbon dioxide and carbon monoxide concentration during the working shift of the photocopying process in a small photocopying shop in Novi Sad, Serbia. The statistically significant differences of target gases were examined with two-way analysis of variance without replication followed by Scheffe's post hoc test. The existence of statistically significant differences was obtained for carbon monoxide emission which is pointed out with F-values (12.37 and 31.88) greater than Fcrit (6.94) in contrary to carbon dioxide emission (F-values of 1.23 and 3.12 were less than Fcrit).  Scheffe's post hoc test indicated that sampling point A (near the photocopier machine) and second time interval contribute the most on carbon monoxide emission.

Keywords: analysis of variance, carbon dioxide, carbon monoxide, photocopying indoor, Scheffe's test

Procedia PDF Downloads 299
24518 Development of Self-Reliant Satellite-Level Propulsion System by Using Hydrogen Peroxide Propellant

Authors: H. J. Liu, Y. A. Chan, C. K. Pai, K. C. Tseng, Y. H. Chen, Y. L. Chan, T. C. Kuo

Abstract:

To satisfy the mission requirement of the FORMOSAT-7 project, NSPO has initialized a self-reliant development on satellite propulsion technology. A trade-off study on different types of on-board propulsion system has been done. A green propellant, high-concentration hydrogen peroxide (H2O2 hereafter), is chosen in this research because it is ITAR-free, nontoxic and easy to produce. As the components designed for either cold gas or hydrazine propulsion system are not suitable for H2O2 propulsion system, the primary objective of the research is to develop the components compatible with H2O2. By cooperating with domestic research institutes and manufacturing vendors, several prototype components, including a diaphragm-type tank, pressure transducer, ball latching valve, and one-Newton thruster with catalyst bed, were manufactured, and the functional tests were performed successfully according to the mission requirements. The requisite environmental tests, including hot firing test, thermal vaccum test, vibration test and compatibility test, are prepared and will be to completed in the near future. To demonstrate the subsystem function, an Air-Bearing Thrust Stand (ABTS) and a real-time Data Acquisition & Control System (DACS) were implemented to assess the performance of the proposed H2O2 propulsion system. By measuring the distance that the thrust stand has traveled in a given time, the thrust force can be derived from the kinematics equation. To validate the feasibility of the approach, it is scheduled to assess the performance of a cold gas (N2) propulsion system prior to the H2O2 propulsion system.

Keywords: FORMOSAT-7, green propellant, Hydrogen peroxide, thruster

Procedia PDF Downloads 400
24517 Macroeconomic Impact of Economic Growth on Unemployment: A Case of South Africa

Authors: Ashika Govender

Abstract:

This study seeks to determine whether Okun’s Law is valid for the South African economy, using time series data for the period 2004 to 2014. The data were accessed from the South African Reserve Bank and Stats SA. The stationarity of the variables was analysed by applying unit root tests via the Augmented Dickey-Fuller test (ADF), the Phillips-Perron (PP) test, and the Kwiatkowski–Phillips–Schmidt–Shin test (KPSS) test. The study used an ordinary least square (OLS) model in analysing the dynamic version of Okun’s law. The Error Correction Model (ECM) was used to analyse the short-run impact of GDP growth on unemployment, as well as the speed of adjustment. The results indicate a short run and long run relationship between unemployment rate and GDP growth rate in period 2004q1-2014q4, suggesting that Okun’s law is valid for the South African economy. With a 1 percent increase in GDP, unemployment can decrease by 0.13 percent, ceteris paribus. The research culminates in important policy recommendations, highlighting the relationship between unemployment and economic growth in the spirit of the National Development Plan.

Keywords: unemployment, economic growth, Okun's law, South Africa

Procedia PDF Downloads 248
24516 A Pretest for Choosing between Stratified Logrank or Wilcoxon in the Two-Sample Problem with Covariate

Authors: Jhoanne Marsh C. Gatpatan, Joshua D. Naranjo

Abstract:

Logrank test and generalized Wilcoxon procedure are the two commonly used tests for comparing survival curves. Between the two, the logrank test is the appropriate test used when the proportional hazards (PH) assumption holds. Alternatively, the Wilcoxon method is used when the PH assumption fails. This is equally true when the data is stratified according to values of a covariate, with the stratified logrank as the first choice and stratified Wilcoxon as the alternative option when diagnostics show that the PH assumption is violated. Moreover, the choice between logrank and Wilcoxon tests also depends on whether survival curves tend to differ early or late in time. In this article, the relative performance of the stratified logrank against the stratified Wilcoxon over a range of treatment effect patterns is investigated. A method for using a Q–statistic to detect whether differences tend to occur early or late across strata are then proposed. Using Q as a pretest, the user will be able to choose the more powerful test under various patterns of deviations from the null hypothesis. Simulations show that the pretest is able to detect the more efficient procedure over varying patterns of treatment effect.

Keywords: covariates, pretest, proportional hazards, stratified logrank, stratified Wilcoxon

Procedia PDF Downloads 54
24515 Explantation of Osseo-Integrated Implant Using Electrosurgery and Ultrasonic Instrumentation

Authors: Stefano Andrea Denes

Abstract:

The use of dental implants to rehabilitate edentulous patients has become a well-established and effective treatment option; however, despite its high success rate, this treatment is not free of complications. The fracture of implant body is a rare cause of failure but when it does occur it can present technical challenges. In this article, we report the complete removal of a fractured osseointegrated implant using electrosurgery and ultrasonic instrumentation. The postoperative course was uneventful, no bleeding, infection, or hematoma formation was observed.

Keywords: dental implant, oral surgery, electrosurgery, piezosurgery

Procedia PDF Downloads 243
24514 Repair Workshop Queue System Modification Using Priority Scheme

Authors: C. Okonkwo Ugochukwu, E. Sinebe Jude, N. Odoh Blessing, E. Okafor Christian

Abstract:

In this paper, a modification on repair workshop queuing system using multi priority scheme was carried out. Chi square goodness of fit test was used to determine the random distribution of the inter arrival time and service time of crankshafts that come for maintenance in the workshop. The chi square values obtained for all the prioritized classes show that the distribution conforms to Poisson distribution. The mean waiting time in queue results of non-preemptive priority for 1st, 2nd and 3rd classes show 0.066, 0.09, and 0.224 day respectively, while preemptive priority show 0.007, 0.036 and 0.258 day. However, when non priority is used, which obviously has no class distinction it amounts to 0.17 days. From the results, one can observe that the preemptive priority system provides a very dramatic improvement over the non preemptive priority as it concerns arrivals that are of higher priority. However, the improvement has a detrimental effect on the low priority class. The trend of the results is similar to the mean waiting time in the system as a result of addition of the actual service time. Even though the mean waiting time for the queue and that of the system for no priority takes the least time when compared with the least priority, urgent and semi-urgent jobs will terribly suffer which will most likely result in reneging or balking of many urgent jobs. Hence, the adoption of priority scheme in this type of scenario will result in huge profit to the Company and more customer satisfaction.

Keywords: queue, priority class, preemptive, non-preemptive, mean waiting time

Procedia PDF Downloads 364
24513 Mechanical Qualification Test Campaign on the Demise Observation Capsule

Authors: B. Tiseo, V. Quaranta, G. Bruno, R. Gardi, T. Watts, S. Dussy

Abstract:

This paper describes the qualification test campaign performed on the Demise Observation Capsule DOC-EQM as part of the Future Launch Preparatory Program FLPP3. The mechanical environment experienced during launch ascent and separation phase was first identified and then replicated in terms of sine, random and shock vibration. The loads identification is derived by selecting the worst possible case. Vibration and shock qualification test performed at CIRA Space Qualification laboratory is herein described. Mechanical fixtures’ design and validation, carried out by means of FEM, is also addressed due to its fundamental role in the vibrational test campaign. The Demise Observation Capsule (DOC) successfully passed the qualification test campaign. Functional test and resonance search have not been point any fault and damages of the capsule.

Keywords: capsule, demise, demise observation capsule, DOC, launch environment, re-ntry, qualification

Procedia PDF Downloads 118
24512 Oakes Test and Proportionality Test: Balance between the Practical Costs of Limiting Rights and the Benefits Arising from the Law

Authors: Rafael Tedrus Bento

Abstract:

The analysis of proportionality as a test is raised as a basic foundation for the achievement of Fundamental Rights. We used legal dogmatics and empirical analysis to seek the expected results, from the reading of the RV Oakes trial by the Supreme Court of Canada. In cases involving freedom of expression, two tests are used to resolve disputes. The first examines whether, in fact, the case can be characterized as a violation of freedom of expression; the second assesses whether this violation can be justified by the reasonable limit clause. This test was defined in the RV Oakes trial by the Supreme Court of Canada, concluding with the Oakes Test, used worldwide as a proportionality test. Resulting is a proportionality between the effects of the limiting measure and the objective - the more serious the harmful effects of a measure, the more important the objective must be.

Keywords: Oakes, proportionality, fundamental rights, Supreme Court of Canada