Search results for: knee arthroplasty
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 296

Search results for: knee arthroplasty

86 Bone Marrow Edema Syndrome in the Foot and Ankle

Authors: S. Alireza Mirghasemi, Elly Trepman, Mohammad Saleh Sadeghi, Narges Rahimi Gabaran, Shervin Rashidinia

Abstract:

Bone marrow edema syndrome (BMES) is an uncommon and self-limited syndrome characterized by atraumatic extremity pain with unknown of etiology. Symptom onset may include sudden or gradual swelling and pain at rest or during activity, usually at night. This syndrome mostly affects middle-aged men and younger women who have pain in the lower extremities. The most common sites involved with BMES, in decreasing order of frequency, are the bones about the hip, knee, ankle, and foot. The diagnosis of BMES is made with magnetic resonance imaging to exclude other causes of bone marrow edema. The correct diagnosis often is delayed because of the low prevalence and nonspecific signs in the foot and ankle. This delay may intensify bone pain and impair patient function and quality of life. The goal of BMES treatment is to relieve pain and shorten disease duration. Treatment options are limited and may include symptomatic treatment, pharmacologic treatment, and surgery.

Keywords: transient osteoporosis, bone marrow edema syndrome, iloprost, bisphosphonates

Procedia PDF Downloads 334
85 Nutrient Foramina in the Shaft of Long Bones of Upper Limb

Authors: Madala Venkateswara Rao

Abstract:

The major blood supply to the long bones occurs through the nutrient arteries, which enters through the nutrient foramina. This is the study of nutrient Foramina in the shaft of upper limb long bones taken from the department of Anatomy at Narayana medical college nellore. Nutrient foramina play an important role in nutrition and growth of the bones. Most of the nutrient arteries follow the rule, 'to the elbow I go, from the knee I flee' but they are very variable in position. Their number, location, direction & its importance in the growing end of long bones were studied in the long bones of upper limb. The present study has variations in the position & direction of long bones especially in the radius & ulna, as most of the nutrient foramina are found in anterior surface of upper 1/3rd and middle 1/3rd of these bones. The study of nutrient foramina is not only of academic interest but also in medico-legal practice in relation to their position. Careful observation has also been made on the position of nutrient foramina in relation to upper end of long bones. This study also gives importance of length long bones to know the height of an individual. With the knowledge of variations in the nutrient foramen, placement of internal fixation devices can be appropriately done.

Keywords: nutrient artery, nutrient foramina, shaft of long bones, upper limb bones

Procedia PDF Downloads 479
84 Self-Regenerating, Vascularizing Hybrid Scaffold-Hydrogel For Bone Tissue Engineering

Authors: Alisha Gupta

Abstract:

Osteoarthritis (OA) is the most common form of arthritis which is a degenerative joint disease causing joints to begin to break down and underlying bones to change. This “wear and tear” most frequently affects hands, hips, and knees. This is important because OA pain is considered to be a leading cause of mobility impairment in older adults, with hip and knee OA ranked 11th highest contributors to global disability. Bone tissue engineering utilizing polymer scaffolds and hydrogels is an emerging field for treating osteoarthritis. Polymer scaffolds provide a three-dimensional structure for tissue growth, and hydrogels can be used to deliver drugs and growth factors. The combination of the two materials creates a hybrid structure that can better withstand physiological and mechanical demands while also providing a more controlled environment for drug and nutrient delivery. I think using bone tissue engineering for making scaffold-hydrogel composites that are self-regenerating and vascularizing might be useful in solving this problem. Successful implementation can reconstruct healthy, simulated bone tissue on deficient applicants.

Keywords: tissue engineering, regenerative medicine, scaffold-hydrogel composites, osteoarthritis

Procedia PDF Downloads 81
83 Geometry of the Bandaging Procedure and Its Application while Wrapping Bandages for Treatment of Leg Ulcers

Authors: Monica Puri Sikka, Subrato Ghosh Arunangshu Mukhopadhyay

Abstract:

Appropriate compression bandaging is important for compression therapeutic medical diseases. The high compression approach employed for treating venous leg ulcers should be used correctly so that sufficient (but not excessive) pressure is applied. Bandages used to treat venous disease by compression should achieve and sustain effective levels and gradients of pressure and minimise the risk of pressure trauma. To maintain graduated compression on the limb the bandage needs to be applied at same tension for each layer from ankle to the knee. In this paper the geometry for various bandaging procedures is used to wrap each layer of bandage by marking the relaxed length of the bandage. The relaxed length is calculated depending on the stretch, average circumference of the limb on which it is to be applied and the bandaging technique to be used. This paper aims at developing a scientific approach while applying the bandage to reduce the inter operator variability in applying same tension on each successive layer of bandage.

Keywords: bandaging, compression, inter operator variability, graduated, relaxed length, stretch

Procedia PDF Downloads 473
82 Realization of Wearable Inertial Measurement Units-Sensor-Fusion Harness to Control Therapeutic Smartphone Applications

Authors: Svilen Dimitrov, Manthan Pancholi, Norbert Schmitz, Didier Stricker

Abstract:

This paper presents the end-to-end development of a wearable motion sensing harness consisting of computational unit and four inertial measurement units to control three smartphone therapeutic games for children. The inertial data is processed in real time to obtain lower body motion information like knee raises, feet taps and squads. By providing a Wi-Fi connection interface the sensor harness acts wireless remote control for smartphone applications. By performing various lower body movements the users provoke corresponding game state changes. In contrary to the current similar offers, like Nintendo Wii Remote, Xbox Kinect and Playstation Move, this product, consisting of the sensor harness and the applications on top of it, are fully wearable, which means they do not rely on the user to be bound to concrete soft- or hardwareequipped space.

Keywords: wearable harness, inertial measurement units, smartphone therapeutic games, motion tracking, lower-body activity monitoring

Procedia PDF Downloads 373
81 Associated Risks of Spontaneous Lung Collapse after Shoulder Surgery: A Literature Review

Authors: Fiona Bei Na Tan, Glen Wen Kiat Ho, Ee Leen Liow, Li Yin Tan, Sean Wei Loong Ho

Abstract:

Background: Shoulder arthroscopy is an increasingly common procedure. Pneumothorax post-shoulder arthroscopy is a rare complication. Objectives: Our aim is to highlight a case report of pneumothorax post shoulder arthroscopy and to conduct a literature review to evaluate the possible risk factors associated with developing a pneumothorax during or after shoulder arthroscopy. Case Report: We report the case of a 75-year-old male non-smoker who underwent left shoulder arthroscopy without regional anaesthesia and in the left lateral position. The general anaesthesia and surgery were uncomplicated. The patient was desaturated postoperatively and was found to have a pneumothorax on examination and chest X-ray. A chest tube drain was inserted promptly into the right chest. He had an uncomplicated postoperative course. Methods: PubMed Medline and Cochrane database search was carried out using the terms shoulder arthroplasty, pneumothorax, pneumomediastinum, and subcutaneous emphysema. We selected full-text articles written in English. Results: Thirty-two articles were identified and thoroughly reviewed. Based on our inclusion and exclusion criteria, 14 articles, which included 20 cases of pneumothorax during or after shoulder arthroscopy, were included. Eighty percent (16/20) of pneumothoraxes occurred postoperatively. In the articles that specify the side of pneumothorax, 91% (10/11) occur on the ipsilateral side of the arthroscopy. Eighty-eight percent (7/8) of pneumothoraxes occurred when subacromial decompression was performed. Fifty-six percent (9/16) occurred in patients placed in the lateral decubitus position. Only 30% (6/20) occurred in current or ex-smokers, and only 25% (5/20) had a pre-existing lung condition. Overall, of the articles that posit a mechanism, 75% (9/12) deem the pathogenesis to be multifactorial. Conclusion: The exact mechanism of pneumothorax is currently unknown. Awareness of this complication and timely recognition are important to prevent life-threatening sequelae. Surgeons should have a low threshold to obtain diagnostic plain radiographs in the event of clinical suspicion.

Keywords: rotator cuff repair, decompression, pressure, complication

Procedia PDF Downloads 44
80 The Effects of Seat Heights and Obesity on Lower-Limb Joint Kinematics during Sit-To-Stand Movement

Authors: Seungwon Baek, Haeseok Jeong, Haehyun Lee, Woojin Park

Abstract:

The main purpose of this study was to compare obese people to the non-obese in terms of joint kinematics in lower-limb body. The height of chairs was also considered as a design factor. Obese people had a difficulty in sit-to-stand (STS) tasks compared to the non-obese people. High chair heights can make STS task easy and it helps the obese to be more comfortable with STS task in particular. Subjects were instructed to wear inertial measurement unit (IMU) sensors. They perform STS task using chairs of different heights. Joint kinematics and subjective ratings of discomfort were measured. Knee angles of the obese group were greater than that of the non-obese group in normal type. No significant difference in joint kinematics was found in high chair. Interaction effect was found between obesity and height of chair. The results verified the previous research that had suggested a biomechanical model of STS movement. The results can be applied to occupational design for the obese.

Keywords: biomechanics, electromyography, joint kinematics, obesity, sitting, sit-to-stand

Procedia PDF Downloads 282
79 Rehabilitative Walking: The Development of a Robotic Walking Training Device Using Functional Electrical Stimulation for Treating Spinal Cord Injuries and Lower-Limb Paralysis

Authors: Chung Hyun Goh, Armin Yazdanshenas, X. Neil Dong, Yong Tai Wang

Abstract:

Physical rehabilitation is a necessary step in regaining lower body function after a partial paralysis caused by a spinal cord injury or a stroke. The purpose of this paper is to present the development and optimization of a training device that accurately recreates the motions in a gait cycle with the goal of rehabilitation for individuals with incomplete spinal cord injuries or who are victims of a stroke. A functional electrical stimulator was used in conjunction with the training device to stimulate muscle groups pertaining to rehabilitative walking. The feasibility and reliability of the design are presented. To validate the design functionality, motion analyses of the knee and ankle gait paths were made using motion capture systems. Key results indicate that the robotic walking training device provides a viable mode of physical rehabilitation.

Keywords: functional electrical stimulation, rehabilitative walking, robotic walking training device, spinal cord injuries

Procedia PDF Downloads 120
78 Higher-Level Return to Female Karate Competition Following Multiple Patella Dislocations

Authors: A. Maso, C. Bellissimo, G. Facchinetti, N. Milani, D. Panzin, D. Pogliana, L. Garlaschelli, L. Rivaroli, S. Rivaroli, M. Zurek, J. Konin

Abstract:

15 year-old female karate athlete experienced two unilateral patella dislocations: one contact and one non-contact. This challenged her from competing as planned at the regional and national competitions as a result of her inability to perform at a high level. Despite these injuries and other complicated factors, she was able to modify her training timeline and successfully perform, winning third at the National Cup. Initial pain numeric rating scale 8/10 during karate training isometric figures, taking the stairs, long walking, a positive rasp test, palpation pain on the lateral patella joint 9/10, pain performing open kinetic chain 0°-45° and close kinetic chain 30°-90°, tensor fascia lata, vastus lateralis, psoas muscles retraction/stiffness. Foot hyper pronation, internally rotated femur, and knee flexion 15° were the postural findings. Exercise prescription for three days/week for three weeks to include exercise-based rehabilitation and soft tissue mobilization with massage and foam rolling. After three weeks, the pain was improved during activity daily living 5/10, and soft tissue stiffness decreased. An additional four weeks of exercise-based rehabilitation was continued. At this time, axial x-rays and TA-GT TAC were taken, and an orthopaedic medical check was recommended to continue conservative treatment. At week seven, she performed 2/4 karate position technique without pain and 2/4 with pain. An isokinetic test was performed at week 12, demonstrating a 10% strength deficit and 6% resistance deficit both to the left hamstrings. Moreover, an 8% strength and resistance surplus to the left quadriceps was found. No pain was present during activity, daily living and sports activity, allowing a return to play training to begin. A plan for the return to play framework collaborated with her trainer, her father, a physiotherapist, a sports scientist, an osteopath, and a nutritionist. Within 4 and 5 months, both non-athlete and athlete movement quality analysis tests were performed. The plan agreed to establish a return to play goal of 7 months and the highest level return to competition goal of 9 months from the start of rehabilitation. This included three days/week of training and repeated testing of movement quality before return to competition with detectable improvements from 77% to 93%. Beginning goals of the rehabilitation plan included the importance of a team approach. The patient’s father and trainer were important to collaborate with to assure a safe and timely return to competition. The possibility of achieving the goals was strongly related to orthopaedic decision-making and progress during the first weeks of rehabilitation. Without complications or setbacks, the patient can successfully return to her highest level of competition. The patient returned to participation after five months of rehabilitation and training, and then she returned to competition at the national level in nine months. The successful return was the result of a team approach and a compliant patient with clear goals.

Keywords: karate, knee, performance, rehabilitation

Procedia PDF Downloads 77
77 A Case Study of a Rehabilitated Child by Joint Efforts of Parents and Community

Authors: Fouzia Arif, Arif S. Mohammad, Hifsa Altaf, Lubna Raees

Abstract:

Introduction: The term "disability", refers to any condition that impedes the completion of daily tasks using traditional methods. In developing countries like Pakistan, disable population is usually excluded from the mainstream. In squatter settlements the situation is more critical. Sultanabad is one of the squatter settlements of Karachi. Purpose of case study is to improve the health of disabled children’s, and create awareness among the parents and community. Through a household visit, Shiraz, a young disabled boy of 15.5 years old was identified. Her mother articulated that her son was living normally and happily with his parents two years back. When he was 13 years old and student of class 8th, both his legs were traumatized in a Railway Train Accident while playing cricket. He got both femoral shaft fractured severely. He was taken to Jinnah Post Graduate Medical Centre (JPMC) where his left leg was amputated at above knee level and right leg was opened & fixed by reduction internally, luckily bone healed moderately with the passage of time. Methods: In Squatter settlements of Karachi Sultanabad, a survey was conducted in two sectors. Disability screening questionnaire was developed, collaboration with community through household visits, outreach sessions 23cases of disabled were identified who were socialized through sports, Musical program and get-together was organized with stockholder for creating awareness among community and parent’s. Collaboration was established with different NGOs, Government, stakeholders and community support for establishment of Physiotherapy Center. During home visit it was identified that Shiraz was on bed since last 1 year, his family could not afforded cost of physiotherapist and medical consultation due to poverty. Parents counseling was done mentioning that Shiraz needed to take treatment. After motivation his parents agreed for treatment. He was consulted by an orthopedic surgeon in AKUH, Who referred to DMC University of Health Science for rehabilitation service. There he was assessed and referred for Community Based Physiotherapy Centre Sultanabad. Physiotherapist visited home along with Coordinator for Special children and assessed him regularly, planned Physiotherapy treatment for abdominal, high muscles strutting exercise foot muscles strengthening exercise, knee mobilization weight bearing from partial to full weight gradually, also strengthen exercise were given for residual limb as the boy was dependent on it. He was also provided by an artificial leg and training was done. Result: Shiraz is now fully mobile, he can walk independently even out of home, functional ability progress improved and dependency factors reduced. It was difficult but not impossible. We all have sympathy but if we have empathy then we can rehabilitate the community in a better way. His parents are very happy and also the community is surprised to see him in such better condition. Conclusion: Combined efforts of physiotherapist, Coordinator of special children, community and parents made a drastic change in Shiraz’s case by continuously motivating him for better outcome. He is going to school regularly without support. Since he belongs to a poor family he faces financial constraints for education and clinical follow ups regularly.

Keywords: femoral shaft fracture, trauma, orthopedic surgeon, physiotherapy treatment

Procedia PDF Downloads 217
76 Modeling of a Pendulum Test Including Skin and Muscles under Compression

Authors: M. J. Kang, Y. N. Jo, H. H. Yoo

Abstract:

Pendulum tests were used to identify a stretch reflex and diagnose spasticity. Some researches tried to make a mathematical model to simulate the motions. Thighs are subject to compressive forces due to gravity during a pendulum test. Therefore, it affects knee trajectories. However, the most studies on the pendulum tests did not consider that conditions. We used Kelvin-Voight model as compression model of skin and muscles. In this study, we investigated viscoelastic behaviors of skin and muscles using gelatin blocks from experiments of the vibration of the compliantly supported beam. Then we calculated a dynamic stiffness and loss factors from the experiment and estimated a damping coefficient of the model. We also did pendulum tests of human lower limbs to validate the stiffness and damping coefficient of a skin model. To simulate the pendulum motion, we derive equations of motion. We used stretch reflex activation model to estimate muscle forces induced by the stretch reflex. To validate the results, we compared the activation with electromyography signals during experiments. The compression behavior of skin and muscles in this study can be applied to analyze sitting posture as wee as developing surgical techniques.

Keywords: Kelvin-Voight model, pendulum test, skin and muscles under compression, stretch reflex

Procedia PDF Downloads 423
75 Chlorine Pretreatment Effect on Mechanical Properties of Optical Fiber Glass

Authors: Abhinav Srivastava, Hima Harode, Chandan Kumar Saha

Abstract:

The principal ingredient of an optical fiber is quartz glass. The quality of the optical fiber decreases if impure foreign substances are attached to its preform surface. If residual strain inside a preform is significant, it cracks with a small impact during drawing or transporting. Furthermore, damages and unevenness on the surface of an optical fiber base material break the fiber during drawing. The present work signifies that chlorine pre-treatment enhances mechanical properties of the optical fiber glass. FTIR (Fourier-Transform Infrared Spectroscopy) results show that chlorine gas chemically modifies the structure of silica clad; chlorine is known to soften glass. Metallic impurities on the preform surface likely formed volatile metal chlorides due to chlorine pretreatment at elevated temperature. The chlorine also acts as a drying agent, and therefore the preform surface is anticipated to be water deficient and supposedly avoids particle adhesion on the glass surface. The Weibull analysis of long length tensile strength demarcates a substantial shift in its knee. The higher dynamic fatigue n-value also indicated surface crack healing.

Keywords: mechanical strength, optical fiber glass, FTIR, Weibull analysis

Procedia PDF Downloads 149
74 A Closed Loop Audit of Pre-operative Transfusion Samples in Orthopaedic Patients at a Major Trauma Centre

Authors: Tony Feng, Rea Thomson, Kathryn Greenslade, Ross Medine, Jennifer Easterbrook, Calum Arthur, Matilda Powell-bowns

Abstract:

There are clear guidelines on taking group and screen samples (G&S) for elective arthroplasty and major trauma. However, there is limited guidance on blood grouping for other trauma patients. The purpose of this study was to review the level of blood grouping at a major trauma centre and validate a protocol that limits the expensive processing of G&S samples. After reviewing the national guidance on transfusion samples in orthopaedic patients, data was prospectively collected for all orthopaedic admissions in the Royal Infirmary of Edinburgh between January to February 2023. The cause of admission, number of G&S samples processed on arrival and need for red cells was collected using the hospital blood bank. A new protocol was devised based on a multidisciplinary meeting which limited the requirement for G&S samples only to presentations in “category X”, including neck-of-femur fractures (NOFs), pelvic fractures and major trauma. A re-audit was completed between April and May after departmental education and institution of this protocol. 759 patients were admitted under orthopaedics in the major trauma centre across two separate months. 47% of patients were admitted with presentations falling in category X (354/759) and patients in this category accounted for 88% (92/104) of those requiring post-operative red cell transfusions. Of these, 51% were attributed to NOFs (47/92). In the initial audit, 50% of trauma patients outwith category X had samples sent (116/230), estimated to cost £3800. Of these 230 patients, 3% required post-operative transfusions (7/230). In the re-audit, 23% of patients outwith category X had samples sent (40/173), estimated to cost £1400, of which 3% (5/173) required transfusions. None of the transfusions in these patients in either audit were related to their operation and the protocol achieved an estimated cost saving of £2400 over one month. This study highlights the importance of sending samples for patients with certain categories of orthopaedic trauma (category X) due to the high demand for post-operative transfusions. However, the absence of transfusion requirements in other presentations suggests over-testing. While implementation of the new protocol has markedly reduced over-testing, additional interventions are required to reduce this further.

Keywords: blood transfusion, quality improvement, orthopaedics, trauma

Procedia PDF Downloads 51
73 A Systematic Review on The Usage of CRISPR-Cas System in The Treatment of Osteoarthritis(OA)

Authors: Atiqah Binti Ab Aziz

Abstract:

Background: It has been estimated that about 250 million people all over the world suffer from osteoarthritis (OA). Thus, OA is a major health problem in urgent need of better treatment. Problem statement: Current therapies for OA can temporarily relieve clinical symptoms and for pain management, rather than preventing or curing OA. Total knee replacement performed at the end stage of the disease is considered the only cure available. Objectives: This article aimed to explore the potential of treating osteoarthritis via the CRISPR Cas system. Methods: Articles that relate to the application of the CRISPR Cas system in osteoarthritis were extracted, categorized, and reviewed through the PRISMA method using PubMed, an engine published from November 2016 to November 2021. Results: There were 30 articles screened. Articles that fall under the categories of non-English articles, full articles that were not available, articles that were not an original articles were excluded. Ultimately, 13 articles were reviewed. Discussion: This review provides an information on the introduction of CRISPR and discussed on their mechanism of actions in extracted studies for OA treatment. Conclusions: It can be seen that not many medical research utilize the CRISPR Cas system as part of the method in the treatment of OA. Hence exploring the extent of the usage of the CRISPR Cas system in OA treatment is important to determine the research gap and point out at which of the research is needed further investigation to avoid redundancy of existing research and ensure the novelty of the research.

Keywords: osteoarthritis, treatment, CRISPR, review, therapy

Procedia PDF Downloads 151
72 Tool Wear Analysis in 3D Manufactured Ti6AI4V

Authors: David Downey

Abstract:

With the introduction of additive manufacturing (3D printing) to produce titanium (Ti6Al4V) components in the medical/aerospace and automotive industries, intricate geometries can be produced with virtually complete design freedom. However, the consideration of microstructural anisotropy resulting from the additive manufacturing process becomes necessary due to this design flexibility and the need to print a geometric shape that can consist of numerous angles, radii, and swept surfaces. A femoral knee implant serves as an example of a 3D-printed near-net-shaped product. The mechanical properties of the printed components, and consequently, their machinability, are affected by microstructural anisotropy. Currently, finish-machining operations performed on titanium printed parts using selective laser melting (SLM) utilize the same cutting tools employed for processing wrought titanium components. Cutting forces for components manufactured through SLM can be up to 70% higher than those for their wrought counterparts made of Ti6Al4V. Moreover, temperatures at the cutting interface of 3D printed material can surpass those of wrought titanium, leading to significant tool wear. Although the criteria for tool wear may be similar for both 3D printed and wrought materials, the rate of wear during the machining process may differ. The impact of these issues on the choice of cutting tool material and tool lifetimes will be discussed.

Keywords: additive manufacturing, build orientation, microstructural anisotropy, printed titanium Ti6Al4V, tool wear

Procedia PDF Downloads 70
71 Configuration Design and Optimization of the Movable Leg-Foot Lunar Soft-Landing Device

Authors: Shan Jia, Jinbao Chen, Jinhua Zhou, Jiacheng Qian

Abstract:

Lunar exploration is a necessary foundation for deep-space exploration. For the functional limitations of the fixed landers which are widely used currently and are to expand the detection range by the use of wheeled rovers with unavoidable path-repeatability, a movable lunar soft-landing device based on cantilever type buffer mechanism and leg-foot type walking mechanism is presented. Firstly, a 20 DoFs quadruped configuration based on pushrod is proposed. The configuration is of the bionic characteristics such as hip, knee and ankle joints, and can make the kinematics of the whole mechanism unchanged before and after buffering. Secondly, the multi-function main/auxiliary buffers based on crumple-energy absorption and screw-nut mechanism, as well as the telescopic device which could be used to protect the plantar force sensors during the buffer process are designed. Finally, the kinematic model of the whole mechanism is established, and the configuration optimization of the whole mechanism is completed based on the performance requirements of slope adaptation and obstacle crossing. This research can provide a technical solution integrating soft-landing, large-scale inspection and material-transfer for future lunar exploration and even mars exploration, and can also serve as the technical basis for developing the reusable landers.

Keywords: configuration design, lunar soft-landing device, movable, optimization

Procedia PDF Downloads 129
70 Motion Performance Analyses and Trajectory Planning of the Movable Leg-Foot Lander

Authors: Shan Jia, Jinbao Chen, Jinhua Zhou, Jiacheng Qian

Abstract:

In response to the functional limitations of the fixed landers, those are to expand the detection range by the use of wheeled rovers with unavoidable path-repeatability in deep space exploration currently, a movable lander based on the leg-foot walking mechanism is presented. Firstly, a quadruped landing mechanism based on pushrod-damping is proposed. The configuration is of the bionic characteristics such as hip, knee and ankle joints, and the multi-function main/auxiliary buffers based on the crumple-energy absorption and screw-nut mechanism. Secondly, the workspace of the end of the leg-foot mechanism is solved by Monte Carlo method, and the key points on the desired trajectory of the end of the leg-foot mechanism are fitted by cubic spline curve. Finally, an optimal time-jerk trajectory based on weight coefficient is planned and analyzed by an adaptive genetic algorithm (AGA). The simulation results prove the rationality and stability of walking motion of the movable leg-foot lander in the star catalogue. In addition, this research can also provide a technical solution integrating of soft-landing, large-scale inspection and material transfer for future star catalogue exploration, and can even serve as the technical basis for developing the reusable landers.

Keywords: motion performance, trajectory planning, movable, leg-foot lander

Procedia PDF Downloads 118
69 Survey of Epidemiology and Mechanisms of Badminton Injury Using Medical Check-Up and Questionnaire of School Age Badminton Players

Authors: Xiao Zhou, Kazuhiro Imai, Xiaoxuan Liu

Abstract:

Badminton is one type of racket sports that requires repetitive overhead motion, with the shoulder in abduction/external rotation and requires players to perform jumps, lunges, and quick directional changes. These characteristics could be stressful for body regions that may cause badminton injuries. Regarding racket players including badminton players, there have not been any studies that have utilized medical check-up to evaluate epidemiology and mechanism of injuries. In addition, epidemiology of badminton injury in school age badminton players is unknown. The first purpose of this study was to investigate the badminton injuries, physical fitness parameters, and intensity of shoulder pain using medical check-up so that the mechanisms of shoulder injuries might be revealed. The second purpose of this study was to survey the distribution of badminton injuries in elementary school age players so that injury prevention can be implemented as early as possible. The results of this study revealed that shoulder pain occurred in all players, and present shoulder pain players had smaller weight, greater shoulder external rotation (ER) gain, significantly thinner circumference of upper limbs and greater trunk extension. Identifying players with specific of these factors may enhance the prevention of badminton injury. This study also shows that there are high incidences of knee, ankle, plantar, and shoulder injury or pain in elementary school age badminton players. Injury prevention program might be implemented for elementary school age players.

Keywords: badminton injury, epidemiology, medical check-up, school age players

Procedia PDF Downloads 115
68 Cartilage Mimicking Coatings to Increase the Life-Span of Bearing Surfaces in Joint Prosthesis

Authors: L. Sánchez-Abella, I. Loinaz, H-J. Grande, D. Dupin

Abstract:

Aseptic loosening remains as the principal cause of revision in total hip arthroplasty (THA). For long-term implantations, submicron particles are generated in vivo due to the inherent wear of the prosthesis. When this occurs, macrophages undergo phagocytosis and secretion of bone resorptive cytokines inducing osteolysis, hence loosening of the implanted prosthesis. Therefore, new technologies are required to reduce the wear of the bearing materials and hence increase the life-span of the prosthesis. Our strategy focuses on surface modification of the bearing materials with a hydrophilic coating based on cross-linked water-soluble (meth)acrylic monomers to improve their tribological behavior. These coatings are biocompatible, with high swelling capacity and antifouling properties, mimicking the properties of natural cartilage, i.e. wear resistance with a permanent hydrated layer that prevents prosthesis damage. Cartilage mimicking based coatings may be also used to protect medical device surfaces from damage and scratches that will compromise their integrity and hence their safety. However, there are only a few reports on the mechanical and tribological characteristics of this type of coatings. Clear beneficial advantages of this coating have been demonstrated in different conditions and different materials, such as Ultra-high molecular weight polyethylene (UHMWPE), Polyethylene (XLPE), Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK), cobalt-chromium (CoCr), Stainless steel, Zirconia Toughened Alumina (ZTA) and Alumina. Using routine tribological experiments, the wear for UHMWPE substrate was decreased by 75% against alumina, ZTA and stainless steel. For PEEK-CFR substrate coated, the amount of material lost against ZTA and CrCo was at least 40% lower. Experiments on hip simulator allowed coated ZTA femoral heads and coated UHMWPE cups to be validated with a decrease of 80% of loss material. Further experiments on hip simulator adding abrasive particles (1 micron sized alumina particles) during 3 million cycles, on a total of 6 million, demonstrated a decreased of around 55% of wear compared to uncoated UHMWPE and uncoated XLPE. In conclusion, CIDETEC‘s hydrogel coating technology is versatile and can be adapted to protect a large range of surfaces, even in abrasive conditions.

Keywords: cartilage, hydrogel, hydrophilic coating, joint

Procedia PDF Downloads 98
67 Development of an Auxetic Tissue Implant

Authors: Sukhwinder K. Bhullar, M. B. G. Jun

Abstract:

The developments in biomedical industry have demanded the development of biocompatible, high performance materials to meet higher engineering specifications. The general requirements of such materials are to provide a combination of high stiffness and strength with significant weight savings, resistance to corrosion, chemical resistance, low maintenance, and reduced costs. Auxetic materials which come under the category of smart materials offer huge potential through measured enhancements in mechanical properties. Unique deformation mechanism, providing cushioning on indentation, automatically adjustable with its strength and thickness in response to forces and having memory returns to its neutral state on dissipation of stresses make them good candidate in biomedical industry. As simple extension and compression of tissues is of fundamental importance in biomechanics, therefore, to study the elastic behaviour of auxetic soft tissues implant is targeted in this paper. Therefore development and characterization of auxetic soft tissue implant is studied in this paper. This represents a real life configuration where soft tissue such as meniscus in knee replacement, ligaments and tendons often are taken as transversely isotropic. Further, as composition of alternating polydisperse blocks of soft and stiff segments combined with excellent biocompatibility make polyurethanes one of the most promising synthetic biomaterials. Hence selecting auxetic polyurathylene foam functional characterization is performed and compared with conventional polyurathylene foam.

Keywords: auxetic materials, deformation mechanism, enhanced mechanical properties, soft tissues

Procedia PDF Downloads 443
66 Pressure Relief in Prosthetic Sockets through Hole Implementation Using Different Materials

Authors: Gabi N. Nehme

Abstract:

Below-knee amputees commonly experience asymmetrical gait patterns. It is generally believed that ischemia is related to the formation of pressure sores due to uneven distribution of forces. Micro-vascular responses can reveal local malnutrition. Changes in local skin blood supply under various external loading conditions have been studied for a number of years. Radionuclide clearance, photo-plethysmography, trans-cutaneous oxygen tension along with other studies showed that the blood supply would be influenced by the epidermal forces, and the rate and the amount of blood supply would decrease with increased epidermal loads being shear forces or normal forces. Several cases of socket designs were investigated using Finite Element Model (FEM) and Design of Experiment (DOE) to increase flexibility and minimize the pressure at the limb/socket interface using ultra high molecular weight polyethylene (UHMWPE) and polyamide 6 (PA6) or Duraform. The pressure reliefs at designated areas where reducing thickness is involved are seen to be critical in determination of amputees’ comfort and are very important to clinical applications. Implementing a hole between the Patellar Tendon (PT) and Distal Tibia (DT) would decrease stiffness and increase prosthesis range of motion where flexibility is needed. In addition, displacement and prosthetic energy storage increased without compromising mechanical efficiency and prosthetic design integrity.

Keywords: patellar tendon, distal tibia, prosthetic socket relief areas, hole implementation

Procedia PDF Downloads 390
65 Malnutrition Among Adult Hospitalized Orthopedic Patients: Nursing Role And Nutrition Screening

Authors: Ehsan Ahmed Yahia

Abstract:

Introduction: The nursing role in nutrition screening and assessing hospitalized patients is important. Malnutrition is a common and costly problem, particularly among hospitalized patients, and can have an adverse effect on the healing process. The study's goal is to assess the prevalence of malnutrition among adult hospitalized orthopedic patients and to detect the barriers to the nutrition screening process. Aim of the study: This study aimed to (a) assess the prevalence of malnutrition in hospitalized orthopedic patients and (b) evaluate the relationship between malnutrition and selected clinical outcomes. Material and Methods: This prospective field study was conducted for three months between 03/2022 and 06/2022 in the selected orthopedic departments in a teaching hospital affiliated withCairo University, Egypt. with a total number of one hundred twenty (120) patients. Patients' assessment included checking for malnutrition using the Nutritional Risk Screening Questionnaire. Patients at risk for malnourishment were defined as NRS score ≥ 3. Clinical outcomes under consideration included 1) length of hospitalization, 2) mobilization after surgery and conservative treatment, and 3) rate of adverse events. Results: This study found that malnutrition is a significant problem among patients hospitalized in an orthopedic ward. The prevalence of malnutrition was the highest in patients with lumbar spine and pelvis fractures, followed by the proximal femur and proximal humerus fractures. Patients at risk for malnutrition had significantly prolonged hospitalization, delayed postoperative mobilization, and increased incidence of adverse events.27.8% of the study sample were at risk for malnutrition. The highest prevalence of malnourishment was found in Septic Surgery with 32%, followed by Traumatology with 19.6% and Arthroplasty with 15.3%. A higher prevalence of malnutrition was detected among patients with typical fractures, such as lumbar spine and pelvis (46.7%), proximal femur (34.4%), and proximal humeral (23.7%) fractures. Additionally, patients at risk for malnutrition showed prolonged hospitalization (14.7 ± 11.1 vs. 21.2 ± 11.7 days), delayed postoperative mobilization (2.3 ± 2.9 vs. 4.1 ± 4.9 days), and delayed to mobilize after conservative treatment (1.1 ± 2.7 vs. 1.8 ± 1.9 days). A significant statistical correlation of NRS with individual parameters (Spearman's rank correlation, p < 0.05) was observed. The rate of adverse incidents in patients at risk for malnutrition was significantly higher than that of patients with a regular nutritional status (37.2% vs. 21.1%, p < 0.001). Conclusions: Our results indicate that the prevalence of malnutrition in surgical patients is significant. The nutritional status of patients with typical fractures is especially at risk. Prolonged hospitalization, delayed postoperative mobilization, and delayed mobilization after conservative treatment is significantly associated with malnutrition. In addition, the incidence of adverse events in patients at risk for malnutrition is significantly higher.

Keywords: malnutrition, nutritional risk screening, surgery, nursing, orthopedic nurse

Procedia PDF Downloads 77
64 Long-Term Sitting Posture Identifier Connected with Cloud Service

Authors: Manikandan S. P., Sharmila N.

Abstract:

Pain in the neck, intermediate and anterior, and even low back may occur in one or more locations. Numerous factors can lead to back discomfort, which can manifest into sensations in the other parts of your body. Up to 80% of people will have low back problems at a certain stage of their lives, making spine-related pain a highly prevalent ailment. Roughly twice as commonly as neck pain, low back discomfort also happens about as often as knee pain. According to current studies, using digital devices for extended periods of time and poor sitting posture are the main causes of neck and low back pain. There are numerous monitoring techniques provided to enhance the sitting posture for the aforementioned problems. A sophisticated technique to monitor the extended sitting position is suggested in this research based on this problem. The system is made up of an inertial measurement unit, a T-shirt, an Arduino board, a buzzer, and a mobile app with cloud services. Based on the anatomical position of the spinal cord, the inertial measurement unit was positioned on the inner back side of the T-shirt. The IMU (inertial measurement unit) sensor will evaluate the hip position, imbalanced shoulder, and bending angle. Based on the output provided by the IMU, the data will be analyzed by Arduino, supplied through the cloud, and shared with a mobile app for continuous monitoring. The buzzer will sound if the measured data is mismatched with the human body's natural position. The implementation and data prediction with design to identify balanced and unbalanced posture using a posture monitoring t-shirt will be further discussed in this research article.

Keywords: IMU, posture, IOT, textile

Procedia PDF Downloads 53
63 Effect of Different Muscle Contraction Mode on the Expression of Myostatin, IGF-1, and PGC-1 Alpha Family Members in Human Vastus Lateralis Muscle

Authors: Pejman Taghibeikzadehbadr

Abstract:

Muscle contraction stimulates a transient change of myogenic factors, partly related to the mode of contractions. Here, we assessed the response of Insulin-like growth factor 1Ea (IGF-1Ea), Insulin-like growth factor 1Eb (IGF-1Eb), Insulin-like growth factor 1Ec (IGF-1Ec), Peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC1α-1), Peroxisome proliferator-activated receptor gamma coactivator 4-alpha (PGC1α-4), and myostatin to the eccentric Vs the concentric contraction in human skeletal muscle. Ten healthy males were performed an acute eccentric and concentric exercise bout (n = 5 per group). For each contraction type, participants performed 12 sets of 10 repetitions knee extension by the dominant leg. Baseline and post-exercise muscle biopsy were taken 4 weeks before and immediately after experimental sessions from Vastus Lateralis muscle. Genes expression was measured by real-time PCR technique. There was a significant increase in PGC1α-1, PGC1α-4, IGF-1Ea and, IGF-1Eb mRNA after concentric contraction (p ≤ 0.05), while the PGC1α-4 and IGF-1Ec significantly increased after eccentric contraction (p ≤ 0.05). It is intriguing to highlight that; no significant differences between groups were evident for changes in any variables following exercise bouts (p ≥ 0.05). Our results found that concentric and eccentric contractions presented different responses in PGC1α-1, IGF-1Ea, IGF-1Eb, and IGF-1Ec mRNA. However, a similar significant increase in mRNA content was observed in PGC1α-4. Further, no apparent differences could be found between the response of genes to eccentric and concentric contraction.

Keywords: eccentric contraction, concentric contraction, gene expression, PGC-1 alpha, IGF-1 Myostatin

Procedia PDF Downloads 143
62 Comparing Effects of Supervised Exercise Therapy versus Home-Based Exercise Therapy on Low Back Pain Severity, Muscle Strength and Anthropometric Parameters in Patients with Nonspecific Chronic Low Back Pain

Authors: Haleh Dadgostar, Faramarz Akbari, Hosien Vahid Tari, Masoud Solaymani-Dodaran, Mohammad Razi

Abstract:

Introduction: There are a number of exercises-protocols have been applied to improve low back pain. We compared the effect of supervised exercise therapy and home-based exercise therapy among patients with nonspecific chronic low back pain. Methods: 70 patients with nonspecific chronic low back pain were randomly (using a random number generator, excel) divided into two groups to compare the effects of two types of exercise therapy. After a common educational session to learn how to live with low back pain as well as to use core training protocols to strengthen the muscles, the subjects were randomly assigned to follow supervised exercise therapy (n = 31) or home-based exercise therapy (n = 34) for 20 weeks. Results: Although both types of exercise programs resulted in reduced pain, this factor decreased more significantly in supervised exercise program. All scores of fitness improved significantly in supervised exercise group. But only knee extensor strength score was increased in the home base exercise group. Conclusion: Comparing between two types of exercise, supervised group exercise showed more effective than the other one. Reduction in low back pain severity and improvement in muscle flexibility and strength can be more achieved by using a 20-week supervised exercise program compared to the home-based exercise program in patients with nonspecific chronic low back pain.

Keywords: low back pain, anthropometric parameters, supervised exercise therapy, home-based exercise therapy

Procedia PDF Downloads 300
61 Mathematical Modelling and AI-Based Degradation Analysis of the Second-Life Lithium-Ion Battery Packs for Stationary Applications

Authors: Farhad Salek, Shahaboddin Resalati

Abstract:

The production of electric vehicles (EVs) featuring lithium-ion battery technology has substantially escalated over the past decade, demonstrating a steady and persistent upward trajectory. The imminent retirement of electric vehicle (EV) batteries after approximately eight years underscores the critical need for their redirection towards recycling, a task complicated by the current inadequacy of recycling infrastructures globally. A potential solution for such concerns involves extending the operational lifespan of electric vehicle (EV) batteries through their utilization in stationary energy storage systems during secondary applications. Such adoptions, however, require addressing the safety concerns associated with batteries’ knee points and thermal runaways. This paper develops an accurate mathematical model representative of the second-life battery packs from a cell-to-pack scale using an equivalent circuit model (ECM) methodology. Neural network algorithms are employed to forecast the degradation parameters based on the EV batteries' aging history to develop a degradation model. The degradation model is integrated with the ECM to reflect the impacts of the cycle aging mechanism on battery parameters during operation. The developed model is tested under real-life load profiles to evaluate the life span of the batteries in various operating conditions. The methodology and the algorithms introduced in this paper can be considered the basis for Battery Management System (BMS) design and techno-economic analysis of such technologies.

Keywords: second life battery, electric vehicles, degradation, neural network

Procedia PDF Downloads 31
60 Effect of Sintering Time and Porosity on Microstructure, Mechanical and Corrosion Properties of Ti6Al15Mo Alloy for Implant Applications

Authors: Jyotsna Gupta, S. Ghosh, S. Aravindan

Abstract:

The requirement of artificial prostheses (such as hip and knee joints) has increased with time. Many researchers are working to develop new implants with improved properties such as excellent biocompatibility with no tissue reactions, corrosion resistance in body fluid, high yield strength and low elastic modulus. Further, the morphological properties of the artificial implants should also match with that of the human bone so that cell adhesion, proliferation and transportation of the minerals and nutrition through body fluid can be obtained. Present study attempts to make porous Ti6Al15Mo alloys through powder metallurgy route using space holder technique. The alloy consists of 6wt% of Al which was taken as α phase stabilizer and 15wt% Mo was taken as β phase stabilizer with theoretical density 4.708. Ammonium hydrogen carbonate is used as a space holder in order to generate the porosity. The porosity of these fabricated porous alloys was controlled by adding the 0, 50, 70 vol.% of the space holder content. Three phases were found in the microstructure: α, α_2 and β phase of titanium. Kirkendall pores are observed to be decreased with increase of holding time during sintering and parallelly compressive strength and elastic modulus value increased slightly. Compressive strength and elastic modulus of porous Ti-6Al-15Mo alloy (1.17 g/cm3 density) is found to be suitable for cancellous bone. Released ions from Ti-6Al-15Mo alloy are far below from the permissible limits in human body.

Keywords: bone implant, powder metallurgy, sintering time, Ti-6Al-15Mo

Procedia PDF Downloads 122
59 Injury Pattern of Field Hockey Players at Different Field Position during Game and Practice

Authors: Sujay Bisht

Abstract:

The purpose of the study was to assess and examines the pattern of injury among the field hockey players at different field position during practice & game. It was hypothesized that the backfield might have the height rate of injury, followed by midfield. Methods: university level and national level male field hockey (N=60) are selected as a subject and requested to respond an anon questionnaire. Personal characteristics of each and individual players were also collected like (age, height, weight); field hockey professional information (level of play, year of experience, playing surface); players injury history (site, types, cause etc). The rates of injury per athlete per year were also calculated. Result: Around half of the injury occurred were to the lower limbs (49%) followed by head and face (30%), upper limbs (19%) and torso region (2%). Injuries included concussion, wounds, broken nose, ligament sprain, dislocation, fracture, and muscles strain and knee injury. The ligament sprain is the highest rate (40%) among the other types of injuries. After investigation and evaluation backfield players had the highest rate of risk of injury (1.10 injury/athletes-year) followed by midfield players (0.70 injury/athlete-year), forward players (0.45 injury/athlete-year) & goalkeeper was (0.37 injury/athlete-year). Conclusion: Due to the different field position the pattern & rate of injury were different. After evaluation, lower limbs had the highest rate of injury followed by head and face, upper limbs and torso respectively. It also revealed that not only there is a difference in the rate of injury between playing the position, but also in the types of injury sustain at a different position.

Keywords: trauma, sprain, strain, astroturf, acute injury

Procedia PDF Downloads 201
58 Body Mass Components in Young Soccer Players

Authors: Elizabeta Sivevska, Sunchica Petrovska, Vaska Antevska, Lidija Todorovska, Sanja Manchevska, Beti Dejanova, Ivanka Karagjozova, Jasmina Pluncevic Gligoroska

Abstract:

Introduction: Body composition plays an important role in the selection of young soccer players and it is associated with their successful performance. The most commonly used model of body composition divides the body into two compartments: fat components and fat-free mass (muscular and bone components). The aims of the study were to determine the body composition parameters of young male soccer players and to show the differences in age groups. Material and methods: A sample of 52 young male soccer players, with an age span from 9 to 14 years were divided into two groups according to the age (group 1 aged 9 to 12 years and group 2 aged 12 to 14 years). Anthropometric measurements were taken according to the method of Mateigka. The following measurements were made: body weight, body height, circumferences (arm, forearm, thigh and calf), diameters (elbow, knee, wrist, ankle) and skinfold thickness (biceps, triceps, thigh, leg, chest, abdomen). The measurements were used in Mateigka’s equations. Results: Body mass components were analyzed as absolute values (in kilograms) and as percentage values: the muscular component (MC kg and MC%), the bone component (BCkg and BC%) and the body fat (BFkg and BF%). The group up to 12 years showed the following mean values of the analyzed parameters: MM=21.5kg; MM%=46.3%; BC=8.1kg; BC%=19.1%; BF= 6.3kg; BF%= 15.7%. The second group aged 12-14 year had mean values of body composition parameters as follows: MM=25.6 kg; MM%=48.2%; BC = 11.4 kg; BC%=21.6%; BF= 8.5 kg; BF%= 14. 7%. Conclusions: The young soccer players aged 12 up to 14 years who are in the pre-pubertal phase of growth and development had higher bone component (p<0.05) compared to younger players. There is no significant difference in muscular and fat body component between the two groups of young soccer players.

Keywords: body composition, young soccer players, body fat, fat-free mass

Procedia PDF Downloads 431
57 Use of Triclosan-Coated Sutures Led to Cost Saving in Public and Private Setting in India across Five Surgical Categories: An Economical Model Assessment

Authors: Anish Desai, Reshmi Pillai, Nilesh Mahajan, Hitesh Chopra, Vishal Mahajan, Ajay Grover, Ashish Kohli

Abstract:

Surgical Site Infection (SSI) is hospital acquired infection of growing concern. This study presents the efficacy and cost-effectiveness of triclosan-coated suture, in reducing the burden of SSI in India. Methodology: A systematic literature search was conducted for economic burden (1998-2018) of SSI and efficacy of triclosan-coated sutures (TCS) vs. non-coated sutures (NCS) (2000-2018). PubMed Medline and EMBASE indexed articles were searched using Mesh terms or Emtree. Decision tree analysis was used to calculate, the cost difference between TCS and NCS at private and public hospitals, respectively for 7 surgical procedures. Results: The SSI range from low to high for Caesarean section (C-section), Laparoscopic hysterectomy (L-hysterectomy), Open Hernia (O-Hernia), Laparoscopic Cholecystectomy (L-Cholecystectomy), Coronary artery bypass graft (CABG), Total knee replacement (TKR), and Mastectomy were (3.77 to 24.2%), (2.28 to 11.7%), (1.75 to 60%), (1.71 to 25.58%), (1.6 to 18.86%), (1.74 to 12.5%), and (5.56 to 25%), respectively. The incremental cost (%) of TCS ranged 0.1%-0.01% in private and from 0.9%-0.09% at public hospitals across all surgical procedures. Cost savings at median efficacy & SSI risk was 6.52%, 5.07 %, 11.39%, 9.63%, 3.62%, 2.71%, 9.41% for C-section, L-hysterectomy, O-Hernia, L-Cholecystectomy, CABG, TKR, and Mastectomy in private and 8.79%, 4.99%, 12.67%, 10.58%, 3.32%, 2.35%, 11.83% in public hospital, respectively. Efficacy of TCS and SSI incidence in a particular surgical procedure were important determinants of cost savings using one-way sensitivity analysis. Conclusion: TCS suture led to cost savings across all 7 surgeries in both private and public hospitals in India.

Keywords: cost Savings, non-coated sutures, surgical site infection, triclosan-coated sutures

Procedia PDF Downloads 372