Search results for: ductile failure
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2476

Search results for: ductile failure

376 Therapeutic Effect of Cichorium Intybus Aerial Parts Extract against Oxidative Stress and Nephropathy Induced by Streptozotocin in Rats

Authors: Josline Salib, Sayed El-Toumy, Abeer Salama, Enayat Omara, Emad Hassan

Abstract:

Diabetic nephropathy is an important cause of morbidity and mortality and is now among the most common causes of end-stage renal failure (ESRF) in developed countries. Thus, the aim of the present study was to investigate the phenolic compounds content of Cichorium intybus aerial parts extracts as well as the therapeutic effects on diabetic nephropathy, oxidative stress, and anti-inflammatory by characterizing biochemical, histopathological changes and immunohistochemistry in an experimental diabetic rat model as compared with Amaryl. Ten known compounds of flavonoids, coumarins and phenolic acid derivatives were isolated from the C. intybus aqueous methanolic extract. Structures of the isolated compounds were established by chromatography, UV and 1D⁄2D 1H⁄ 13C spectroscopy. The aqueous methanol extract of C. intybus aerial parts was administered to Streptozotocin diabetes rats at doses (100 and 200 mg/kg) for 21 days. After treatment, blood glucose, serum insulin, urea, creatinine, and TNF-α were evaluated. Enzymatic scavengers including catalase (CAT), glutathione (GSH), malondialdehyde (MDA) and nitric oxide (NO) were determined to evaluate the oxidative status in the renal tissue. Diabetic rats treated with C. intybus extract showed a dose-dependent reduction of fasting blood glucose and kidney antioxidant status in comparison to the diabetic control group. The extract was able to enhance the antioxidant defenses of the kidney by increasing the reduced GSH and CAT content and decreasing MDA content in addition to significantly decreasing kidney nitric oxide content compared to diabetic control rats. Furthermore, the histopathological findings in C. intybus extract administered rats were observed at markedly lesser extent than the diabetic control group. Also, inducible nitric oxide synthase (iNOS) levels were decreased significantly after the administration of high-dose C. intybus extract in diabetic rats. Showing significant antihyperglycemic and antioxidant properties of C. intybus aerial parts extract, which is attributed to its polyphenolic content, may offer a potential source for the treatment of diabetes.

Keywords: antioxidant activity, anti-diabetic nephropathy, cichorium intybus aerial parts, phenolic compounds

Procedia PDF Downloads 121
375 Simulation of Maximum Power Point Tracking in a Photovoltaic System: A Circumstance Using Pulse Width Modulation Analysis

Authors: Asowata Osamede

Abstract:

Optimized gain in respect to output power of stand-alone photovoltaic (PV) systems is one of the major focus of PV in recent times. This is evident to its low carbon emission and efficiency. Power failure or outage from commercial providers in general does not promote development to the public and private sector, these basically limit the development of industries. The need for a well-structured PV system is of importance for an efficient and cost-effective monitoring system. The purpose of this paper is to validate the maximum power point of an off-grid PV system taking into consideration the most effective tilt and orientation angles for PV's in the southern hemisphere. This paper is based on analyzing the system using a solar charger with MPPT from a pulse width modulation (PWM) perspective. The power conditioning device chosen is a solar charger with MPPT. The practical setup consists of a PV panel that is set to an orientation angle of 0o north, with a corresponding tilt angle of 36 o, 26o and 16o. The load employed in this set-up are three Lead Acid Batteries (LAB). The percentage fully charged, charging and not charging conditions are observed for all three batteries. The results obtained in this research is used to draw the conclusion that would provide a benchmark for researchers and scientist worldwide. This is done so as to have an idea of the best tilt and orientation angles for maximum power point in a basic off-grid PV system. A quantitative analysis would be employed in this research. Quantitative research tends to focus on measurement and proof. Inferential statistics are frequently used to generalize what is found about the study sample to the population as a whole. This would involve: selecting and defining the research question, deciding on a study type, deciding on the data collection tools, selecting the sample and its size, analyzing, interpreting and validating findings Preliminary results which include regression analysis (normal probability plot and residual plot using polynomial 6) showed the maximum power point in the system. The best tilt angle for maximum power point tracking proves that the 36o tilt angle provided the best average on time which in turns put the system into a pulse width modulation stage.

Keywords: power-conversion, meteonorm, PV panels, DC-DC converters

Procedia PDF Downloads 149
374 Standardization of Solar Water Pumping System for Remote Areas in Indonesia

Authors: Danar Agus Susanto, Hermawan Febriansyah, Meilinda Ayundyahrini

Abstract:

The availability of spring water to meet people demand is often a problem, especially in tropical areas with very limited surface water sources, or very deep underground water. Although the technology and equipment of pumping system are available and easy to obtain, but in remote areas, the availability of pumping system is difficult, due to the unavailability of fuel or the lack of electricity. Solar Water Pumping System (SWPS) became one of the alternatives that can overcome these obstacles. In the tropical country, sunlight can be obtained throughout the year, even in remote areas. SWPS were already widely built in Indonesia, but many encounter problems during operations, such as decreased of efficiency; pump damaged, damaged of controllers or inverters, and inappropriate photovoltaic performance. In 2011, International Electrotechnical Commission (IEC) issued the IEC standard 62253:2011 titled Photovoltaic pumping systems - Design qualification and performance measurements. This standard establishes design qualifications and performance measurements related to the product of a solar water pumping system. National Standardization Agency of Indonesia (BSN) as the national standardization body in Indonesia, has not set the standard related to solar water pumping system. This research to study operational procedures of SWPS by adopting of IEC Standard 62253:2011 to be Indonesia Standard (SNI). This research used literature study and field observation for installed SWPS in Indonesia. Based on the results of research on SWPS already installed in Indonesia, IEC 62253: 2011 standard can improve efficiency and reduce operational failure of SWPS. SWPS installed in Indonesia still has GAP of 51% against parameters in IEC standard 62253: 2011. The biggest factor not being met is related to operating and maintenance handbooks for personnel that included operation and repair procedures. This may result in operator ignorance in installing, operating and maintaining the system. The Photovoltaic (PV) was also the most non-compliance factor of 71%, although there are 22 Indonesia Standard (SNI) for PV (modules, installation, testing, and construction). These research samples (installers, manufacturers/distributors, and experts) agreed on the parameter in the IEC standard 62253: 2011 able to improve the quality of SWPS in Indonesia. Recommendations of this study, that is required the adoption of IEC standard 62253:2011 into SNI to support the development of SWPS for remote areas in Indonesia.

Keywords: efficiency, inappropriate installation, remote areas, solar water pumping system, standard

Procedia PDF Downloads 199
373 Strengthening Reinforced Concrete Beams Using Carbon Fibre Reinforced Polymer Strips

Authors: Mina Iskander, Mina Melad, Mourad Yasser, Waleed Abdel Rahim, Amr Mosa, Mohamed El Lahamy, Ezzeldin Sayed-Ahmed, Mohamed Abou-Zeid

Abstract:

Strengthening of reinforced concrete beams in flexure using externally bonded composite laminate of high tensile strength is easy and of the minimum cost compared to traditional methods such as increasing the concrete section depth or reinforcement that requires formwork and curing which affect the structure usability. One of the main limitations of this technique is debonding of the externally bonded laminate, either by end delamination or by mid-span flexural crack-induced debonding. ACI 440.2-08 suggests that using side-bonded FRP laminate in the flexural strengthening of RC beams may serve to limit the extent and width of flexural cracks. Consequently, this technique may decrease the effect of flexural cracks on initiating the mid-span debonding; i.e. delays the flexural crack-induced debonding. Furthermore, bonding the FRP strips to the side of the beam may offer an attractive, practical solution when the soffit of this beam is not accessible. This paper presents an experimental programme designed to investigate the effect of using externally bonded CFRP laminate on the sides of reinforced concrete beams and compares the results to those of bonding the CFRP laminate to the soffit of the beams. In addition, the paper discusses the effect of using end anchorage by U-wrapping the CFRP strips at their end zones with CFRP sheets for beams strengthened with soffit-bonded and side-bonded CFRP strips. Thus, ten rectangular reinforced concrete beams were tested to failure in order to study the effect of changing the location of the externally bonded laminate on the flexural capacity and ductility of the strengthened beams. Pultruded CFRP strips were bonded to the soffit of the beams or their sides to check the possibility of limiting the flexural cracking in mid-span region, which is the main reason for mid-span debonding. Pre-peg CFRP sheets were used near the support as U-wrap for the beam to act as an end-anchorage for the externally bonded strips in order to delay/prevent the end delamination. Strength gains of 38% and 43% were recorded for the soffit-bonded and the side-bonded composite strips with end U-wrapped sheets, respectively. Furthermore, beams with end sheets applied as an end anchorage showed higher ductility than those without these sheets.

Keywords: flexural strengthening, externally bonded CFRP, side-bonded CFRP, CFRP laminates

Procedia PDF Downloads 356
372 Money Laundering Risk Assessment in the Banking Institutions: An Experimental Approach

Authors: Yusarina Mat-Isa, Zuraidah Mohd-Sanusi, Mohd-Nizal Haniff, Paul A. Barnes

Abstract:

In view that money laundering has become eminent for banking institutions, it is an obligation for the banking institutions to adopt a risk-based approach as the integral component of the accepted policies on anti-money laundering. In doing so, those involved with the banking operations are the most critical group of personnel as these are the people who deal with the day-to-day operations of the banking institutions and are obligated to form a judgement on the level of impending risk. This requirement is extended to all relevant banking institutions staff, such as tellers and customer account representatives for them to identify suspicious customers and escalate it to the relevant authorities. Banking institutions staffs, however, face enormous challenges in identifying and distinguishing money launderers from other legitimate customers seeking genuine banking transactions. Banking institutions staffs are mostly educated and trained with the business objective in mind to serve the customers and are not trained to be “detectives with a detective’s power of observation”. Despite increasing awareness as well as trainings conducted for the banking institutions staff, their competency in assessing money laundering risk is still insufficient. Several gaps have prompted this study including the lack of behavioural perspectives in the assessment of money laundering risk in the banking institutions. Utilizing experimental approach, respondents are randomly assigned within a controlled setting with manipulated situations upon which judgement of the respondents is solicited based on various observations related to the situations. The study suggests that it is imperative that informed judgement is exercised in arriving at the decision to proceed with the banking services required by the customers. Judgement forms a basis of opinion for the banking institution staff to decide if the customers posed money laundering risk. Failure to exercise good judgement could results in losses and absorption of unnecessary risk into the banking institutions. Although the banking institutions are exposed with choices of automated solutions in assessing money laundering risk, the human factor in assessing the risk is indispensable. Individual staff in the banking institutions is the first line of defence who are responsible for screening the impending risk of any customer soliciting for banking services. At the end of the spectrum, the individual role involvement on the subject of money laundering risk assessment is not a substitute for automated solutions as human judgement is inimitable.

Keywords: banking institutions, experimental approach, money laundering, risk assessment

Procedia PDF Downloads 267
371 Analysis of Sickle Cell Disease and Maternal Mortality in United Kingdom

Authors: Basma Hassabo, Sarah Ahmed, Aisha Hameed

Abstract:

Aims and Objectives: To determine the incidence of maternal mortality amongst pregnant women with sickle cell disease (SCD) in the United Kingdom and to determine exact cause of death in these women. Background: SCD is caused by the ‘sickle’ gene and is characterized by episodes of severe bone pain and other complications like acute chest syndrome, chronic pulmonary hypertension, stroke, retinopathy, chronic renal failure, hepato-splenic crises, avascular bone necrosis, sepsis and leg ulcers. SCD is a continual cause of maternal mortality and fetal complications, and it comprises 1.5% of all Direct and Indirect deaths in the UK. Sepsis following premature rupture of membranes with ascending infection, post-partum infection and pre-labour overwhelming septic shock is one of its leading causes of death. Over the last fifty years of maternal mortality reports in UK, between 1 to 4 pregnant women died in each triennium. Material and Method: This is a retrospective study that involves pregnant women who died from SCD complications in the UK between 1952-2012. Data were collected from the UK Confidential Enquiries into Maternal Death and its causes between 1952–2012. Prior to 1985, exact cause of death in this cohort was not recorded. Results: 33 deaths reported between 1964 and 1984. 17 deaths were reported due to sickle cell disease between 1985 and 2012. Five women in this group died of sickle cell crisis, one woman had liver sequestration crisis, two women died of venous thromboembolism, two had myocardial fibrosis and three died of sepsis. Remaining women died of amniotic fluid embolism, SUDEP, myocardial ischemia and intracranial haemorrhage. Conclusion: The leading causes of death in sickle cell sick pregnant women are sickle cell crises, sepsis, venous thrombosis and thromboembolism. Prenatal care for women with SCD should be managed by a multidisciplinary team that includes an obstetrician, nutritionist, primary care physician, and haematologist. In every sick Sickle Cell woman Sickle Cell crises should be on the top of the list of differential diagnosis. Aggressive treatment of complications with low threshold to commence broad-spectrum antibiotics and LMWH contribute to better outcomes.

Keywords: incidence, maternal mortality, sickle cell disease (SCD), uk

Procedia PDF Downloads 239
370 Prevalence of Anxiety among End Stage Renal Disease Patients and Its Association with Patient Compliance to Hemodialysis and Physician Instructions

Authors: Mohammed Asiri, Saleh Alsuwayt, Mohammed Bin Mugren, Abdulmalik Almufarrih, Tariq Alotaibi, Saad Almodameg

Abstract:

Background: End-stage renal disease is a major public health concern with high incidence and mortality rate. Most of ESRD patients are on hemodialysis therapy which is a long-term treatment that disturbs patients’ lifestyle. As a result, he will be susceptible to develop psychiatric disorders like anxiety that may direct him to non-compliance on physician instructions and hemodialysis therapy. Although there are studies conducted on psychiatric issues in hemodialysis patients, but few studies focused on the effect of anxiety disorder and the patient’s compliance. Hence, we are interested in determining the prevalence of anxiety disorder among hemodialysis patients in Saudi Arabia, as well as in defining the correlation between anxiety disorder and compliance on physician instructions and hemodialysis therapy. We hypothesize that our study will show a higher prevalence of anxiety in hemodialysis patients than in general population. Also, we expect the anxiety to have a negative impact on their compliance. Methodology: We used a cross-sectional study design carried out at dialysis unit of four major hospitals in Riyadh, KSA. We interviewed 235 End Stage Renal Disease male and female patients who are on hemodialysis. We divided the patients into two categories according to their compliance. we used modified general questionnaire to get their demographic data, then we used a psychometric response scale called visual analog scale (VAS) to assess patient’s compliance to hemodialysis and physician’s instructions. Also, we used the Arabic validated version of the hospital anxiety and depression scale (HAD scale) used mainly for anxiety assessment. Results: The overall response rate was 54%. Respondents included 147 (62.6%) males and 88 (37.4%) females. The prevalence of anxiety among hemodialysis patients is 13.3%. According to visual analog scale, we found that 189 compliant patients and 45 non-compliant patients. For HAD scale, the mean ± standard deviation of the total score for females was (4.44 ± 4.7) and it’s higher than males which was 2.65 ± 3.08 (P-value= 0.002). The mean ± standard deviation of HAD score in the non-compliant group was (5.88  4.88) and it was higher than the compliant group (2.7  3.32) (P-value= 0.004). Among non-complaint group, 33.3% of anxious patients were males and 66.6% were females. There was a negative correlation between HAD score of anxiety and visual analog scale (R= - 0.285). Conclusion: We conclude that there is a high prevalence of anxiety among patients with End Stage Renal Disease that was higher in females with association of non-compliance to physician’s instructions and hemodialysis therapy.

Keywords: anxiety, end-stage renal disease, renal failure, anxiety disorder

Procedia PDF Downloads 275
369 Usability Testing on Information Design through Single-Lens Wearable Device

Authors: Jae-Hyun Choi, Sung-Soo Bae, Sangyoung Yoon, Hong-Ku Yun, Jiyoung Kwahk

Abstract:

This study was conducted to investigate the effect of ocular dominance on recognition performance using a single-lens smart display designed for cycling. A total of 36 bicycle riders who have been cycling consistently were recruited and participated in the experiment. The participants were asked to perform tasks riding a bicycle on a stationary stand for safety reasons. Independent variables of interest include ocular dominance, bike usage, age group, and information layout. Recognition time (i.e., the time required to identify specific information measured with an eye-tracker), error rate (i.e. false answer or failure to identify the information in 5 seconds), and user preference scores were measured and statistical tests were conducted to identify significant results. Recognition time and error ratio showed significant difference by ocular dominance factor, while the preference score did not. Recognition time was faster when the single-lens see-through display on the dominant eye (average 1.12sec) than on the non-dominant eye (average 1.38sec). Error ratio of the information recognition task was significantly lower when the see-through display was worn on the dominant eye (average 4.86%) than on the non-dominant eye (average 14.04%). The interaction effect of ocular dominance and age group was significant with respect to recognition time and error ratio. The recognition time of the users in their 40s was significantly longer than the other age groups when the display was placed on the non-dominant eye, while no difference was observed on the dominant eye. Error ratio also showed the same pattern. Although no difference was observed for the main effect of ocular dominance and bike usage, the interaction effect between the two variables was significant with respect to preference score. Preference score of daily bike users was higher when the display was placed on the dominant eye, whereas participants who use bikes for leisure purposes showed the opposite preference patterns. It was found more effective and efficient to wear a see-through display on the dominant eye than on the non-dominant eye, although user preference was not affected by ocular dominance. It is recommended to wear a see-through display on the dominant eye since it is safer by helping the user recognize the presented information faster and more accurately, even if the user may not notice the difference.

Keywords: eye tracking, information recognition, ocular dominance, smart headware, wearable device

Procedia PDF Downloads 273
368 An Evaluation of Medical Waste in Health Facilities through Data Envelopment Analysis (DEA) Method: Turkey-Amasya Public Hospitals Union Model

Authors: Murat Iskender Aktaş, Sadi Ergin, Rasime Acar Aktaş

Abstract:

In the light of fast-paced changes and developments in the health sector, the Ministry of Health started a new structuring with decree law numbered 663 within the scope of the Project of Transformation in Health. Accordingly, hospitals should ensure patient satisfaction through more efficient, more effective use of resources and sustainable finance by placing patients in the centre and should operate to increase efficiency to its maximum level while doing these. Within this study, in order to find out how efficient the hospitals were in terms of medical waste management between the years 2011-2014, the data from six hospitals of Amasya Public Hospitals Union were evaluated separately through Data Envelopment Analysis (DEA) method. First of all, input variables were determined. Input variables were the number of patients admitted to polyclinics, the number of inpatients in clinics, the number of patients who were operated and the number of patients who applied to the laboratory. Output variable was the cost of medical wastes in Turkish liras. Each hospital’s total medical waste level before and after public hospitals union; the amounts of average medical waste per patient admitted to polyclinics, per inpatient in clinics, per patient admitted to laboratory and per operated patient were compared within each group. In addition, average medical waste levels and costs were compared for Turkey in general and Europe in general. Paired samples t-test was used to find out whether the changes (increase-decrease) after public hospitals union were statistically significant. The health facilities that were unsuccessful in terms of medical waste management before and after public hospital union and the factors that caused this failure were determined. Based on the results, for each health facility that was ineffective in terms of medical waste management, the level of improvement required for each input was determined. The results of the study showed that there was an improvement in medical waste management applications after the health facilities became a member of public hospitals union; their medical waste levels were lower than the average of Turkey and Europe while the averages of cost of disposal were the highest.

Keywords: medical waste management, cost of medical waste, public hospitals, data envelopment analysis

Procedia PDF Downloads 416
367 The Role of Autophagy Modulation in Angiotensin-II Induced Hypertrophy

Authors: Kitti Szoke, Laszlo Szoke, Attila Czompa, Arpad Tosaki, Istvan Lekli

Abstract:

Autophagy plays an important role in cardiac hypertrophy, which is one of the most common causes of heart failure in the world. This self-degradative catabolic process, responsible for protein quality control, balancing sources of energy at critical times, and elimination of damaged organelles. The autophagic activity can be triggered by starvation, oxidative stress, or pharmacological agents, like rapamycin. This induced autophagy can promote cell survival during starvation or pathological stress. In this study, it is investigated the effect of the induced autophagic process on angiotensin induced hypertrophic H9c2 cells. In our study, it is used H9c2 cells as an in vitro model. To induce hypertrophy, cells were treated with 10000 nM angiotensin-II, and to activate autophagy, 100 nM rapamycin treatment was used. The following groups were formed: 1: control, 2: 10000 nM AT-II, 3: 100 nM rapamycin, 4: 100 nM rapamycin pretreatment then 10000 nM AT-II. The cell viability was examined via MTT (cell proliferation assay) assay. The cells were stained with rhodamine-conjugated phalloidin and DAPI to visualize F-actin filaments and cell nuclei then the cell size alteration was examined in a fluorescence microscope. Furthermore, the expression levels of autophagic and apoptotic proteins such as Beclin-1, p62, LC3B-II, Cleaved Caspase-3 were evaluated by Western blot. MTT assay result suggests that the used pharmaceutical agents in the tested concentrations did not have a toxic effect; however, at group 3, a slight decrement was detected in cell viability. In response to AT-II treatment, a significant increase was detected in the cell size; cells became hypertrophic. However, rapamycin pretreatment slightly reduced the cell size compared to group 2. Western blot results showed that AT-II treatment-induced autophagy, because the increased expression of Beclin-1, p62, LC3B-II were observed. However, due to the incomplete autophagy, the apoptotic Cleaved Caspase-3 expression also increased. Rapamycin pretreatment up-regulated Beclin-1 and LC3B-II, down-regulated p62 and Cleaved Caspase-3, indicating that rapamycin-induced autophagy can restore the normal autophagic flux. Taken together, our results suggest that rapamycin activated autophagy reduces angiotensin-II induced hypertrophy.

Keywords: angiotensin-II, autophagy, H9c2 cell line, hypertrophy, rapamycin

Procedia PDF Downloads 148
366 Intellectual Property Rights Reforms and the Quality of Exported Goods

Authors: Gideon Ndubuisi

Abstract:

It is widely acknowledged that the quality of a country’s export matters more decisively than the quantity it exports. Hence, understanding the drivers of exported goods’ quality is a relevant policy question. Among other things, product quality upgrading is a considerable cost uncertainty venture that can be undertaken by an entrepreneur. Once a product is successfully upgraded, however, others can imitate the product, and hence, the returns to the pioneer entrepreneur are socialized. Along with this line, a government policy such as intellectual property rights (IPRs) protection which lessens the non-appropriability problem and incentivizes cost discovery investments becomes both a panacea in addressing the market failure and a sine qua non for an entrepreneur to engage in product quality upgrading. In addendum, product quality upgrading involves complex tasks which often require a lot of knowledge and technology sharing beyond the bounds of the firm thereby creating rooms for knowledge spillovers and imitations. Without an institution that protects upstream suppliers of knowledge and technology, technology masking occurs which bids up marginal production cost and product quality fall. Despite these clear associations between IPRs and product quality upgrading, the surging literature on the drivers of the quality of exported goods has proceeded almost in isolation of IPRs protection as a determinant. Consequently, the current study uses a difference-in-difference method to evaluate the effects of IPRs reforms on the quality of exported goods in 16 developing countries over the sample periods of 1984-2000. The study finds weak evidence that IPRs reforms increase the quality of all exported goods. When the industries are sorted into high and low-patent sensitive industries, however, we find strong indicative evidence that IPRs reform increases the quality of exported goods in high-patent sensitive sectors both in absolute terms and relative to the low-patent sensitive sectors in the post-reform period. We also obtain strong indicative evidence that it brought the quality of exported goods in the high-patent sensitive sectors closer to the quality frontier. Accounting for time-duration effects, these observed effects grow over time. The results are also largely consistent when we consider the sophistication and complexity of exported goods rather than just quality upgrades.

Keywords: exports, export quality, export sophistication, intellectual property rights

Procedia PDF Downloads 125
365 Quantum Cum Synaptic-Neuronal Paradigm and Schema for Human Speech Output and Autism

Authors: Gobinathan Devathasan, Kezia Devathasan

Abstract:

Objective: To improve the current modified Broca-Wernicke-Lichtheim-Kussmaul speech schema and provide insight into autism. Methods: We reviewed the pertinent literature. Current findings, involving Brodmann areas 22, 46, 9,44,45,6,4 are based on neuropathology and functional MRI studies. However, in primary autism, there is no lucid explanation and changes described, whether neuropathology or functional MRI, appear consequential. Findings: We forward an enhanced model which may explain the enigma related to autism. Vowel output is subcortical and does need cortical representation whereas consonant speech is cortical in origin. Left lateralization is needed to commence the circuitry spin as our life have evolved with L-amino acids and left spin of electrons. A fundamental species difference is we are capable of three syllable-consonants and bi-syllable expression whereas cetaceans and songbirds are confined to single or dual consonants. The 4 key sites for speech are superior auditory cortex, Broca’s two areas, and the supplementary motor cortex. Using the Argand’s diagram and Reimann’s projection, we theorize that the Euclidean three dimensional synaptic neuronal circuits of speech are quantized to coherent waves, and then decoherence takes place at area 6 (spherical representation). In this quantum state complex, 3-consonant languages are instantaneously integrated and multiple languages can be learned, verbalized and differentiated. Conclusion: We postulate that evolutionary human speech is elevated to quantum interaction unlike cetaceans and birds to achieve the three consonants/bi-syllable speech. In classical primary autism, the sudden speech switches off and on noted in several cases could now be explained not by any anatomical lesion but failure of coherence. Area 6 projects directly into prefrontal saccadic area (8); and this further explains the second primary feature in autism: lack of eye contact. The third feature which is repetitive finger gestures, located adjacent to the speech/motor areas, are actual attempts to communicate with the autistic child akin to sign language for the deaf.

Keywords: quantum neuronal paradigm, cetaceans and human speech, autism and rapid magnetic stimulation, coherence and decoherence of speech

Procedia PDF Downloads 195
364 Engineering Analysis for Fire Safety Using Computational Fluid Dynamic (CFD)

Authors: Munirajulu M, Srikanth Modem

Abstract:

A large cricket stadium with the capacity to accommodate several thousands of spectators has the seating arena consisting of a two-tier arrangement with an upper and a lower bowl and an intermediate concourse podium level for pedestrian movement to access the bowls. The uniqueness of the stadium is that spectators can have an unobstructed view from all around the podium towards the field of play. Upper and lower bowls are connected by stairs. The stairs landing is a precast slab supported by cantilevered steel beams. These steel beams are fixed to precast columns supporting the stadium structure. The stair slabs are precast concrete supported on a landing slab and cantilevered steel beams. During an event of a fire at podium level between two staircases, fire resistance of steel beams is very critical to life safety. If the steel beam loses its strength due to lack of fire resistance, it will be weak in supporting stair slabs and may lead to a hazard in evacuating occupants from the upper bowl to the lower bowl. In this study, to ascertain fire rating and life safety, a performance-based design using CFD analysis is used to evaluate the steel beams' fire resistance. A fire size of 3.5 MW (convective heat output of fire) with a wind speed of 2.57 m/s is considered for fire and smoke simulation. CFD results show that the smoke temperature near the staircase/ around the staircase does not exceed 1500 C for the fire duration considered. The surface temperature of cantilevered steel beams is found to be less than or equal to 1500 C. Since this temperature is much less than the critical failure temperature of steel (5200 C), it is concluded that the design of structural steel supports on the staircase is adequate and does not need additional fire protection such as fire-resistant coating. CFD analysis provided an engineering basis for the performance-based design of steel structural elements and an opportunity to optimize fire protection requirements. Thus, performance-based design using CFD modeling and simulation of fire and smoke is an innovative way to evaluate fire rating requirements, ascertain life safety and optimize the design with regard to fire protection on structural steel elements.

Keywords: fire resistance, life safety, performance-based design, CFD analysis

Procedia PDF Downloads 193
363 The Relationships between AntimüLlerian Hormone, Androgens and Ovarian Reserve in Non-Obese East Indian Women with and without Polycystic Ovary Syndrome

Authors: Dipanshu Sur, Ratnabali Chakravorty, Rimi Pal, Siddhartha Chatterjee, Joyshree Chaterjee, Amal Mallik

Abstract:

Background: Polycystic ovary syndrome (PCOS) is a common endocrine disease in reproductive women with a complex hormonal disturbance that affects the menstrual cycle and leads to metabolic consequences in later life. Hyperandrogenaemia is noticeable features of PCOS and influence the process of folliculogenesis in women. The levels of Antimüllerian Hormone (AMH) reflect the number of pre-antral follicles and thus are a marker of oocyte pool – germinal reserve of the ovary for reproduction. Besides its utilization in IVF (In-vitro fertilization), determination of AMH may serve as an additional marker in the diagnostics of PCOS, where increased AMH levels reflect the severity of the disease. The positive correlation of serum AMH with the number of antral follicles was found also in patients with PCOS. Objective: The objective of this study was to investigate the relationship between AMH androgens and whether AMH contributes to altered folliculogenesis in non-obese women with PCOS. Methods: We designed a prospective study which included a total of 65 IVF individuals. It enrolled 26 cases of PCOS based on 2003 Rotterdam criteria and 39 ovulatory normal- non PCOS, healthy, age-matched controls. AMH levels and ovarian morphology were assessed. The relationships between AMH and androgenaemia in patients with and without PCOS were studied. Results: Mean age of PCOS patients were slightly higher than controls (32±4 and 28±3 years, respectively). AMH generally increased with antral follicle count (AFC) [P=0.001], testosterone, and luteinising hormone, and decreased with age, and serum sex hormone binding globulin (SHBG). No significant relationships were found between circulating AMH levels and BMI between PCOS and non-PCOS patients. The calculation of AMH production per antral follicle (AMH/AF) showed that there was a significant difference in median AMH/AF between PCOS and non-PCOS (P =0.001). Both PCOS and non-PCOS groups showed a very similar increase in AMH with increases in AFC, but the PCOS patients had consistently higher AMH across all AFC levels. Conclusions: These observations indicate that there is a connection between AMH and androgens levels between PCOS and non-PCOS East Indian women. Excessive granulosa cell activity may be implicated in the abnormal follicular dynamic of the syndrome. They are higher in women with PCOS and, on the other hand, very low in women with an ovarian failure.

Keywords: anti-Mullerian hormone, polycystic ovary syndrome, antral follicle count, androgens

Procedia PDF Downloads 215
362 A Double-Blind, Randomized, Controlled Trial on N-Acetylcysteine for the Prevention of Acute Kidney Injury in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation

Authors: Sara Ataei, Molouk Hadjibabaie, Amirhossein Moslehi, Maryam Taghizadeh-Ghehi, Asieh Ashouri, Elham Amini, Kheirollah Gholami, Alireza Hayatshahi, Mohammad Vaezi, Ardeshir Ghavamzadeh

Abstract:

Acute kidney injury (AKI) is one of the complications of hematopoietic stem cell transplantation and is associated with increased mortality. N-acetylcysteine (NAC) is a thiol compound with antioxidant and vasodilatory properties that has been investigated for the prevention of AKI in several clinical settings. In the present study, we evaluated the effects of intravenous NAC on the prevention of AKI in allogeneic hematopoietic stem cell transplantation patients. A double-blind randomized placebo-controlled trial was conducted, and 80 patients were recruited to receive 100 mg/kg/day NAC or placebo as intermittent intravenous infusion from day -6 to day +15. AKI was determined on the basis of the Risk-Injury-Failure-Loss-Endstage renal disease and AKI Network criteria as the primary outcome. We assessed urine neutrophil gelatinase-associated lipocalin (uNGAL) on days -6, -3, +3, +9, and +15 as the secondary outcome. Moreover, transplant-related outcomes and NAC adverse reactions were evaluated during the study period. Statistical analysis was performed using appropriate parametric and non-parametric methods including Kaplan–Meier for AKI and generalized estimating equation for uNGAL. At the end of the trial, data from 72 patients were analyzed (NAC: 33 patients and placebo: 39 patients). Participants of each group were not different considering baseline characteristics. AKI was observed in 18% of NAC recipients and 15% of placebo group patients, and the occurrence pattern was not significantly different (p = 0.73). Moreover, no significant difference was observed between groups for uNGAL measures (p = 0.10). Transplant-related outcomes were similar for both groups, and all patients had successful engraftment. Three patients did not tolerate NAC because of abdominal pain, shortness of breath and rash with pruritus and were dropped from the intervention group before transplantation. However, the frequency of adverse reactions was not significantly different between groups. In conclusion, our findings could not show any clinical benefits from high-dose NAC particularly for AKI prevention in allogeneic hematopoietic stem cell transplantation patients.

Keywords: acute kidney injury, N-acetylcysteine, hematopoietic stem cell transplantation, urine neutrophil gelatinase-associated lipocalin, randomized controlled trial

Procedia PDF Downloads 434
361 Impact of Instrument Transformer Secondary Connections on Performance of Protection System: Experiences from Indian POWERGRID

Authors: Pankaj Kumar Jha, Mahendra Singh Hada, Brijendra Singh, Sandeep Yadav

Abstract:

Protective relays are commonly connected to the secondary windings of instrument transformers, i.e., current transformers (CTs) and/or capacitive voltage transformers (CVTs). The purpose of CT and CVT is to provide galvanic isolation from high voltages and reduce primary currents and voltages to a nominal quantity recognized by the protective relays. Selecting the correct instrument transformers for an application is imperative: failing to do so may compromise the relay’s performance, as the output of the instrument transformer may no longer be an accurately scaled representation of the primary quantity. Having an accurately rated instrument transformer is of no use if these devices are not properly connected. The performance of the protective relay is reliant on its programmed settings and on the current and voltage inputs from the instrument transformers secondary. This paper will help in understanding the fundamental concepts of the connections of Instrument Transformers to the protection relays and the effect of incorrect connection on the performance of protective relays. Multiple case studies of protection system mal-operations due to incorrect connections of instrument transformers will be discussed in detail in this paper. Apart from the connection issue of instrument transformers to protective relays, this paper will also discuss the effect of multiple earthing of CTs and CVTs secondary on the performance of the protection system. Case studies presented in this paper will help the readers to analyse the problem through real-world challenges in complex power system networks. This paper will also help the protection engineer in better analysis of disturbance records. CT and CVT connection errors can lead to undesired operations of protection systems. However, many of these operations can be avoided by adhering to industry standards and implementing tried-and-true field testing and commissioning practices. Understanding the effect of missing neutral of CVT, multiple earthing of CVT secondary, and multiple grounding of CT star points on the performance of the protection system through real-world case studies will help the protection engineer in better commissioning the protection system and maintenance of the protection system.

Keywords: bus reactor, current transformer, capacitive voltage transformer, distance protection, differential protection, directional earth fault, disturbance report, instrument transformer, ICT, REF protection, shunt reactor, voltage selection relay, VT fuse failure

Procedia PDF Downloads 83
360 Impact of Short-Term Drought on Vegetation Health Condition in the Kingdom of Saudi Arabia Using Space Data

Authors: E. Ghoneim, C. Narron, I. Iqbal, I. Hassan, E. Hammam

Abstract:

The scarcity of water is becoming a more prominent threat, especially in areas that are already arid in nature. Although the Kingdom of Saudi Arabia (KSA) is an arid country, its southwestern region offers a high variety of botanical landscapes, many of which are wooded forests, while the eastern and northern regions offer large areas of groundwater irrigated farmlands. At present, some parts of KSA, including forests and farmlands, have witnessed protracted and severe drought due to change in rainfall pattern as a result of global climate change. Such prolonged drought that last for several consecutive years is expected to cause deterioration of forested and pastured lands as well as cause crop failure in the KSA (e.g., wheat yield). An analysis to determine vegetation drought vulnerability and severity during the growing season (September-April) over a fourteen year period (2000-2014) in KSA was conducted using MODIS Terra imagery. The Vegetation Condition Index (VCI), derived from the Normalized Difference Vegetation Index (NDVI), and the Temperature Condition Index (TCI), derived from the Land Surface Temperature (LST) data was extracted from MODIS Terra Images. The VCI and TCI were then combined to compute the Vegetation Health Index (VHI). The VHI revealed the overall vegetation health for the area under investigation. A preliminary outcome of the modeled VHI over KSA, using averaged monthly vegetation data over a 14-year period, revealed that the vegetation health condition is deteriorating over time in both naturally vegetated areas and irrigated farmlands. The derived drought map for KSA indicates that both extreme and severe drought occurrences have considerably increased over the same study period. Moreover, based on the cumulative average of drought frequency in each governorate of KSA it was determined that Makkah and Jizan governorates to the east and southwest, witness the most frequency of extreme drought, whereas Tabuk to the northwest, exhibits the less extreme drought frequency. Areas where drought is extreme or severe would most likely have negative influences on agriculture, ecosystems, tourism, and even human welfare. With the drought risk map the kingdom could make informed land management decisions including were to continue with agricultural endeavors and protect forested areas and even where to develop new settlements.

Keywords: drought, vegetation health condition, TCI, Saudi Arabia

Procedia PDF Downloads 387
359 Constructed Wetlands with Subsurface Flow for Nitrogen and Metazachlor Removal from Tile Drainage: First Year Results

Authors: P. Fucik, J. Vymazal, M. Seres

Abstract:

Pollution from agricultural drainage is a severe issue for water quality, and it is a major reason for the failure in accomplishment of 'good chemical status' according to Water Framework Directive, especially due to high nitrogen and pesticide burden of receiving waters. Constructed wetlands were proposed as a suitable measure for removal of nitrogen from agricultural drainage in the early 1990s. Until now, the vast majority of constructed wetlands designed to treat tile drainage were free-surface constructed wetlands. In 2018, three small experimental constructed wetlands with horizontal subsurface flow were built in Czech Highlands to treat tile drainage from 15.73 ha watershed. The wetlands have a surface area of 79, 90 and 98 m² and were planted with Phalaris arundinacea and Glyceria maxima in parallel bands. The substrate in the first two wetlands is gravel (4-8 mm) mixed with birch woodchips (10:1 volume ratio). In one of those wetlands, the water level is kept 10 cm above the surface; in the second one, the water is kept below the surface. The third wetland has 20 cm layer of birch woodchips on top of gravel. The drainage outlet, as well as wetland outlets, are equipped with automatic discharge-gauging devices, temperature probes, as well as automatic water samplers (Teledyne ISCO). During the monitored period (2018-2019), the flows were unexpectedly low due to a drop of the shallow ground water level, being the main source of water for the monitored drainage system, as experienced at many areas of the Czech Republic. The mean water residence time was analyzed in the wetlands (KBr), which was 16, 9 and 27 days, respectively. The mean total nitrogen concentration eliminations during one-year period were 61.2%, 62.6%, and 70.9% for wetlands 1, 2, and 3, respectively. The average load removals amounted to 0.516, 0.323, and 0.399 g N m-2 d-1 or 1885, 1180 and 1457 kg ha-1 yr-1 in wetlands 1, 2 and 3, respectively. The plant uptake and nitrogen sequestration in aboveground biomass contributed only marginally to the overall nitrogen removal. Among the three variants, the one with shallow water on the surface was revealed to be the most effective for removal of nitrogen from drainage water. In August 2019, herbicide Metazachlor was experimentally poured in time of 2 hours at drainage outlet in a concentration of 250 ug/l to find out the removal rates of the aforementioned wetlands. Water samples were taken the first day every six hours, and for the next nine days, every day one water sample was taken. The removal rates were as follows 94, 69 and 99%; when the most effective wetland was the one with the longest water residence time and the birch woodchip-layer on top of gravel.

Keywords: constructed wetlands, metazachlor, nitrogen, tile drainage

Procedia PDF Downloads 151
358 A Case Study of the Saudi Arabian Investment Regime

Authors: Atif Alenezi

Abstract:

The low global oil price poses economic challenges for Saudi Arabia, as oil revenues still make up a great percentage of its Gross Domestic Product (GDP). At the end of 2014, the Consultative Assembly considered a report from the Committee on Economic Affairs and Energy which highlights that the economy had not been successfully diversified. There thus exist ample reasons for modernising the Foreign Direct Investment (FDI) regime, primarily to achieve and maintain prosperity and facilitate peace in the region. Therefore, this paper aims at identifying specific problems with the existing FDI regime in Saudi Arabia and subsequently some solutions to those problems. Saudi Arabia adopted its first specific legislation in 1956, which imposed significant restrictions on foreign ownership. Since then, Saudi Arabia has modernised its FDI framework with the passing of the Foreign Capital Investment Act 1979 and the Foreign Investment Law2000 and the accompanying Executive Rules 2000 and the recently adopted Implementing Regulations 2014.Nonetheless, the legislative provisions contain various gaps and the failure to address these gaps creates risks and uncertainty for investors. For instance, the important topic of mergers and acquisitions has not been addressed in the Foreign Investment Law 2000. The circumstances in which expropriation can be considered to be in the public interest have not been defined. Moreover, Saudi Arabia has not entered into many bilateral investment treaties (BITs). This has an effect on the investment climate, as foreign investors are not afforded typical rights. An analysis of the BITs which have been entered into reveals that the national treatment standard and stabilisation, umbrella or renegotiation provisions have not been included. This is problematic since the 2000 Act does not spell out the applicable standard in accordance with which foreign investors should be treated. Moreover, the most-favoured-nation (MFN) or fair and equitable treatment (FET) standards have not been put on a statutory footing. Whilst the Arbitration Act 2012 permits that investment disputes can be internationalised, restrictions have been retained. The effectiveness of international arbitration is further undermined because Saudi Arabia does not enforce non-domestic arbitral awards which contravene public policy. Furthermore, the reservation to the Convention on the Settlement of Investment Disputes allows Saudi Arabia to exclude petroleum and sovereign disputes. Interviews with foreign investors, who operate in Saudi Arabia highlight additional issues. Saudi Arabia ought not to procrastinate far-reaching structural reforms.

Keywords: FDI, Saudi, BITs, law

Procedia PDF Downloads 410
357 Electronic Six-Minute Walk Test (E-6MWT): Less Manpower, Higher Efficiency, and Better Data Management

Authors: C. M. Choi, H. C. Tsang, W. K. Fong, Y. K. Cheng, T. K. Chui, L. Y. Chan, K. W. Lee, C. K. Yuen, P. W. Lau, Y. L. To, K. C. Chow

Abstract:

Six-minute walk test (6MWT) is a sub-maximal exercise test to assess aerobic capacity and exercise tolerance of patients with chronic respiratory disease and heart failure. This has been proven to be a reliable and valid tool and commonly used in clinical situations. Traditional 6MWT is labour-intensive and time-consuming especially for patients who require assistance in ambulation and oxygen use. When performing the test with these patients, one staff will assist the patient in walking (with or without aids) while another staff will need to manually record patient’s oxygen saturation, heart rate and walking distance at every minute and/or carry oxygen cylinder at the same time. Physiotherapist will then have to document the test results in bed notes in details. With the use of electronic 6MWT (E-6MWT), patients wear a wireless oximeter that transfers data to a tablet PC via Bluetooth. Real-time recording of oxygen saturation, heart rate, and distance are displayed. No manual work on recording is needed. The tablet will generate a comprehensive report which can be directly attached to the patient’s bed notes for documentation. Data can also be saved for later patient follow up. This study was carried out in North District Hospital. Patients who followed commands and required 6MWT assessment were included. Patients were assigned to study or control groups. In the study group, patients adopted the E-6MWT while those in control group adopted the traditional 6MWT. Manpower and time consumed were recorded. Physiotherapists also completed a questionnaire about the use of E-6MWT. Total 12 subjects (Study=6; Control=6) were recruited during 11-12/2017. An average number of staff required and time consumed in traditional 6MWT were 1.67 and 949.33 seconds respectively; while in E-6MWT, the figures were 1.00 and 630.00 seconds respectively. Compared to traditional 6MWT, E-6MWT required 67.00% less manpower and 50.10% less in time spent. Physiotherapists (n=7) found E-6MWT is convenient to use (mean=5.14; satisfied to very satisfied), requires less manpower and time to complete the test (mean=4.71; rather satisfied to satisfied), has better data management (mean=5.86; satisfied to very satisfied) and is recommended to be used clinically (mean=5.29; satisfied to very satisfied). It is proven that E-6MWT requires less manpower input with higher efficiency and better data management. It is welcomed by the clinical frontline staff.

Keywords: electronic, physiotherapy, six-minute walk test, 6MWT

Procedia PDF Downloads 155
356 Multi-Scale Damage Modelling for Microstructure Dependent Short Fiber Reinforced Composite Structure Design

Authors: Joseph Fitoussi, Mohammadali Shirinbayan, Abbas Tcharkhtchi

Abstract:

Due to material flow during processing, short fiber reinforced composites structures obtained by injection or compression molding generally present strong spatial microstructure variation. On the other hand, quasi-static, dynamic, and fatigue behavior of these materials are highly dependent on microstructure parameters such as fiber orientation distribution. Indeed, because of complex damage mechanisms, SFRC structures design is a key challenge for safety and reliability. In this paper, we propose a micromechanical model allowing prediction of damage behavior of real structures as a function of microstructure spatial distribution. To this aim, a statistical damage criterion including strain rate and fatigue effect at the local scale is introduced into a Mori and Tanaka model. A critical local damage state is identified, allowing fatigue life prediction. Moreover, the multi-scale model is coupled with an experimental intrinsic link between damage under monotonic loading and fatigue life in order to build an abacus giving Tsai-Wu failure criterion parameters as a function of microstructure and targeted fatigue life. On the other hand, the micromechanical damage model gives access to the evolution of the anisotropic stiffness tensor of SFRC submitted to complex thermomechanical loading, including quasi-static, dynamic, and cyclic loading with temperature and amplitude variations. Then, the latter is used to fill out microstructure dependent material cards in finite element analysis for design optimization in the case of complex loading history. The proposed methodology is illustrated in the case of a real automotive component made of sheet molding compound (PSA 3008 tailgate). The obtained results emphasize how the proposed micromechanical methodology opens a new path for the automotive industry to lighten vehicle bodies and thereby save energy and reduce gas emission.

Keywords: short fiber reinforced composite, structural design, damage, micromechanical modelling, fatigue, strain rate effect

Procedia PDF Downloads 109
355 Managing of Cobalt and Chromium Ions by Patients with Metal-on-Metal Hip Prosthesis

Authors: Alina Beraudi, Simona Catalani, Dalila De Pasquale, Eva Bianconi, Umberto Santoro, Susanna Stea, Pietro Apostoli

Abstract:

Recently the European Community, in line with the international scientific community such as with the Consensus Statement, has determined to stop the use of metal-on-metal big head stemmed hip prosthesis. Among the factors accounted as responsible for the high failure rates of these hip implants are the release and accumulation of metal ions. Many studies have correlated the presence of these ions, besides other factors, with the induction of oxidative stress response. In our study on 12 subjects, we observed the patient specific capability to eliminate metal ions after revision surgery. While for cobalt all the patients were able to completely excrete cobalt ions within 5-7 months after metal-on-metal bearing removal, for chromium ions it didn’t happen. If on the one hand the toxicokinetic differences between the two types of ions are confirmed by toxicological and occupational studies, on the other hand, this peculiar way of exposition represents a novel and important point of view. Thus, two different approaches were performed to better understand the subject specific capability to transport metal ions (albumin study) and to manage the response to them (heme-oxygenase-1 study): - a mutational screening of ALBUMIN gene was conducted in 30 MoM prosthetic patients resulting in the absence of nucleotidic changes compared with the ALB reference sequence. To this study was also added the analysis of expression of modified albumin protein; - a gene and protein expression study on 44 patients of heme-oxygenase-1, that is one of the most important antioxidant enzyme induced by metallic ions, was performed. This study resulted in no statistically significant differences in the expression of the gene and protein heme-oxygenase-1 between prosthetic and non-prosthetic patients, as well as between patients with high and low ions levels. Our results show that the protein studied (albumin and heme-oxygenase-1) seem to be not involved in determining chromium and cobalt ions level. On the other hand, achromium and cobalt elimination rates are different, but similar in all patients analyzed, suggesting that this process could be not patient-related. We support the importance of researching more about ions transport within the organism once released by hip prosthesis, about the chemical species involved, the districts where they are contained and the mechanisms of elimination, not excluding the existence of a subjective susceptibility to these metals ions.

Keywords: chromium, cobalt, hip prosthesis, individual susceptibility

Procedia PDF Downloads 384
354 Advanced Deployable/Retractable Solar Panel System for Satellite Applications

Authors: Zane Brough, Claudio Paoloni

Abstract:

Modern low earth orbit (LEO) satellites that require multi-mission flexibility are highly likely to be repositioned between different operational orbits. While executing this process the satellite may experience high levels of vibration and environmental hazards, exposing the deployed solar panel to dangerous stress levels, fatigue and space debris, hence it is desirable to retract the solar array before satellite repositioning to avoid damage or failure. Furthermore, to accommodate for today's technological world, the power demand of a modern LEO satellite is rapidly increasing, which consequently provides pressure upon the design of the satellites solar array system to conform to the strict volume and mass limitations. A novel concept of deployable/retractable hybrid solar array system, aimed to provide a greater power to volume ratio while dramatically reducing the disadvantages of system mass and cost is proposed. Taking advantage of the new lightweight technology in solar panels, a mechanical system composed of both rigid and flexible solar panels arranged within a petal formation is proposed to yield a stowed to deployment area ratio up to at least 1:7, which improves the power density dramatically. The system consists of five subsystems, the outer ones based on a novel eight-petal configuration that provides a large surface and supports the flexible solar panels. A single cable and spool based hinge mechanism were designed to synchronously deploy/retract the panels in a safe, simple and efficient manner while the mass compared to the previous systems is considerably reduced. The relevant challenge to assure a smooth movement is resolved by a proper minimization of the gearing system and the use of a micro-controller system. A prototype was designed by 3D simulators and successfully constructed and tested. Further design works are in progress to implement an epicyclical gear hinge mechanism, which will further reduce the volume, mass and complexity of the system significantly. The proposed system due to an effective and reliable mechanism provides a large active surface, whilst being very compact. It could be extremely advantageous for use as ground portable solar panel system.

Keywords: mechatronic engineering, satellite, solar panel, deployable/retractable mechanism

Procedia PDF Downloads 380
353 Effect of Operative Stabilization on Rib Fracture Healing in Porcine Experimental Model: A Pilot Study

Authors: Maria Stepankova, Lucie Vistejnova, Pavel Klein, Tereza Blassova, Marketa Slajerova, Radek Sedlacek, Martin Bartos, Jaroslav Chlupac

Abstract:

Background: Clinical outcome benefits of the segment rib fracture surgical therapy are well known and follow from better stabilization of the chest wall. Despite this, some authors still incline to conservative therapy and point out to possible rib fracture healing failure in connection with the bone vascular supply disturbance caused by metal plate implantation. This suggestion met neither experimental nor clinical verification and remains the object of discussion. In our pilot study we investigated the titanium plate fixation effect on the rib fracture healing in porcine model and its histological, biomechanical and radiological aspects. Materials and Method: Two porcine models (experimental group) underwent the operative chest wall stabilization with a titanium plate implantation after osteotomy. Two other porcine models (control group) were treated conservatively after osteotomy. Three weeks after surgery, all animals were sacrificed, treated ribs were explanted and the histological analysis, µCT imaging and biomechanical testing of the calluses tissue were performed. Results: In µCT imaging, experimental group showed a higher cortical bone volume compared to the control group. Histological analysis using the non-decalcified bone tissue blocks demonstrated more maturated callus with higher newly-formed osseous tissue ratio in experimental group in comparison to controls. In contrast, no significant differences in bone blood vessels supply in both groups were observed. This finding suggests that the bone blood supply in experimental group was not impaired. Biomechanical analysis using 3-point bending test demonstrated significantly higher bending stiffness and the maximum force in experimental group. Conclusion: Based on our observation, it could be concluded, that the titanium plate fixation of the rib fractures leads to faster bone callus maturation whereas does not cause the vascular supply impairment after 3 weeks and thus has a beneficial effect on the rib fracture healing.

Keywords: bone vascular supply, chest wall stabilization, fracture healing, histological analysis, titanium plate implantation

Procedia PDF Downloads 141
352 Fabric-Reinforced Cementitious Matrix (FRCM)-Repaired Corroded Reinforced Concrete (RC) Beams under Monotonic and Fatigue Loads

Authors: Mohammed Elghazy, Ahmed El Refai, Usama Ebead, Antonio Nanni

Abstract:

Rehabilitating corrosion-damaged reinforced concrete (RC) structures has been accomplished using various techniques such as steel plating, external post-tensioning, and external bonding of fiber reinforced polymer (FRP) composites. This paper reports on the use of an innovative technique to strengthen corrosion-damaged RC structures using fabric-reinforced cementitious matrix (FRCM) composites. FRCM consists of dry-fiber fabric embedded in cement-based matrix. Twelve large-scale RC beams were constructed and tested in flexural monotonic and fatigue loads. Prior to testing, ten specimens were subjected to accelerated corrosion process for 140 days leading to an average mass loss in the tensile steel bars of 18.8 %. Corrosion was restricted to the main reinforcement located in the middle third of the beam span. Eight corroded specimens were repaired and strengthened while two virgin and two corroded-unrepaired/unstrengthened beams were used as benchmarks for comparison purpose. The test parameters included the FRCM materials (Carbon-FRCM, PBO-FRCM), the number of FRCM plies, the strengthening scheme, and the type of loading (monotonic and fatigue). The effects of the pervious parameters on the flexural response, the mode of failure, and the fatigue life were reported. Test results showed that corrosion reduced the yield and ultimate strength of the beams. The corroded-unrepaired specimen failed to meet the provisions of the ACI-318 code for crack width criteria. The use of FRCM significantly increased the ultimate strength of the corroded specimen by 21% and 65% more than that of the corroded-unrepaired specimen. Corrosion significantly decreased the fatigue life of the corroded-unrepaired beam by 77% of that of the virgin beam. The fatigue life of the FRCM repaired-corroded beams increased to 1.5 to 3.8 times that of the corroded-unrepaired beam but was lower than that of the virgin specimen. The specimens repaired with U-wrapped PBO-FRCM strips showed higher fatigue life than those repaired with the end-anchored bottom strips having similar number of PBO-FRCM-layers. PBO-FRCM was more effective than Carbon-FRCM in restoring the fatigue life of the corroded specimens.

Keywords: corrosion, concrete, fabric-reinforced cementitious matrix (FRCM), fatigue, flexure, repair

Procedia PDF Downloads 296
351 Utilising Indigenous Knowledge to Design Dykes in Malawi

Authors: Martin Kleynhans, Margot Soler, Gavin Quibell

Abstract:

Malawi is one of the world’s poorest nations and consequently, the design of flood risk management infrastructure comes with a different set of challenges. There is a lack of good quality hydromet data, both in spatial terms and in the quality thereof and the challenge in the design of flood risk management infrastructure is compounded by the fact that maintenance is almost completely non-existent and that solutions have to be simple to be effective. Solutions should not require any further resources to remain functional after completion, and they should be resilient. They also have to be cost effective. The Lower Shire Valley of Malawi suffers from frequent flood events. Various flood risk management interventions have been designed across the valley during the course of the Shire River Basin Management Project – Phase I, and due to the data poor environment, indigenous knowledge was relied upon to a great extent for hydrological and hydraulic model calibration and verification. However, indigenous knowledge comes with the caveat that it is ‘fuzzy’ and that it can be manipulated for political reasons. The experience in the Lower Shire valley suggests that indigenous knowledge is unlikely to invent a problem where none exists, but that flood depths and extents may be exaggerated to secure prioritization of the intervention. Indigenous knowledge relies on the memory of a community and cannot foresee events that exceed past experience, that could occur differently to those that have occurred in the past, or where flood management interventions change the flow regime. This complicates communication of planned interventions to local inhabitants. Indigenous knowledge is, for the most part, intuitive, but flooding can sometimes be counter intuitive, and the rural poor may have a lower trust of technology. Due to a near complete lack of maintenance of infrastructure, infrastructure has to be designed with no moving parts and no requirement for energy inputs. This precludes pumps, valves, flap gates and sophisticated warning systems. Designs of dykes during this project included ‘flood warning spillways’, that double up as pedestrian and animal crossing points, which provide warning of impending dangerous water levels behind dykes to residents before water levels that could cause a possible dyke failure are reached. Locally available materials and erosion protection using vegetation were used wherever possible to keep costs down.

Keywords: design of dykes in low-income countries, flood warning spillways, indigenous knowledge, Malawi

Procedia PDF Downloads 284
350 Risk of Fatal and Non-Fatal Coronary Heart Disease and Stroke Events among Adult Patients with Hypertension: Basic Markov Model Inputs for Evaluating Cost-Effectiveness of Hypertension Treatment: Systematic Review of Cohort Studies

Authors: Mende Mensa Sorato, Majid Davari, Abbas Kebriaeezadeh, Nizal Sarrafzadegan, Tamiru Shibru, Behzad Fatemi

Abstract:

Markov model, like cardiovascular disease (CVD) policy model based simulation, is being used for evaluating the cost-effectiveness of hypertension treatment. Stroke, angina, myocardial infarction (MI), cardiac arrest, and all-cause mortality were included in this model. Hypertension is a risk factor for a number of vascular and cardiac complications and CVD outcomes. Objective: This systematic review was conducted to evaluate the comprehensiveness of this model across different regions globally. Methods: We searched articles written in the English language from PubMed/Medline, Ovid/Medline, Embase, Scopus, Web of Science, and Google scholar with a systematic search query. Results: Thirteen cohort studies involving a total of 2,165,770 (1,666,554 hypertensive adult population and 499,226 adults with treatment-resistant hypertension) were included in this scoping review. Hypertension is clearly associated with coronary heart disease (CHD) and stroke mortality, unstable angina, stable angina, MI, heart failure (HF), sudden cardiac death, transient ischemic attack, ischemic stroke, subarachnoid hemorrhage, intracranial hemorrhage, peripheral arterial disease (PAD), and abdominal aortic aneurism (AAA). Association between HF and hypertension is variable across regions. Treatment resistant hypertension is associated with a higher relative risk of developing major cardiovascular events and all-cause mortality when compared with non-resistant hypertension. However, it is not included in the previous CVD policy model. Conclusion: The CVD policy model used can be used in most regions for the evaluation of the cost-effectiveness of hypertension treatment. However, hypertension is highly associated with HF in Latin America, the Caribbean, Eastern Europe, and Sub-Saharan Africa. Therefore, it is important to consider HF in the CVD policy model for evaluating the cost-effectiveness of hypertension treatment in these regions. We do not suggest the inclusion of PAD and AAA in the CVD policy model for evaluating the cost-effectiveness of hypertension treatment due to a lack of sufficient evidence. Researchers should consider the effect of treatment-resistant hypertension either by including it in the basic model or during setting the model assumptions.

Keywords: cardiovascular disease policy model, cost-effectiveness analysis, hypertension, systematic review, twelve major cardiovascular events

Procedia PDF Downloads 73
349 Barriers of the Development and Implementation of Health Information Systems in Iran

Authors: Abbas Sheikhtaheri, Nasim Hashemi

Abstract:

Health information systems have great benefits for clinical and managerial processes of health care organizations. However, identifying and removing constraints and barriers of implementing and using health information systems before any implementation is essential. Physicians are one of the main users of health information systems, therefore, identifying the causes of their resistance and concerns about the barriers of the implementation of these systems is very important. So the purpose of this study was to determine the barriers of the development and implementation of health information systems in terms of the Iranian physicians’ perspectives. In this study conducted in 8 selected hospitals affiliated to Tehran and Iran Universities of Medical Sciences, Tehran, Iran in 2014, physicians (GPs, residents, interns, specialists) in these hospitals were surveyed. In order to collect data, a research made questionnaire was used (Cronbach’s α = 0.95). The instrument included 25 about organizational (9), personal (4), moral and legal (3) and technical barriers (9). Participants were asked to answer the questions using 5 point scale Likert (completely disagree=1 to completely agree=5). By using a simple random sampling method, 200 physicians (from 600) were invited to study that eventually 163 questionnaires were returned. We used mean score and t-test and ANOVA to analyze the data using SPSS software version 17. 52.1% of respondents were female. The mean age was 30.18 ± 7.29. The work experience years for most of them were between 1 to 5 years (80.4 percent). The most important barriers were organizational ones (3.4 ± 0.89), followed by ethical (3.18 ± 0.98), technical (3.06 ± 0.8) and personal (3.04 ± 1.2). Lack of easy access to a fast Internet (3.67±1.91) and the lack of exchanging information (3.61±1.2) were the most important technical barriers. Among organizational barriers, the lack of efficient planning for the development and implementation systems (3.56±1.32) and was the most important ones. Lack of awareness and knowledge of health care providers about the health information systems features (3.33±1.28) and the lack of physician participation in planning phase (3.27±1.2) as well as concerns regarding the security and confidentiality of health information (3.15 ± 1.31) were the most important personal and ethical barriers, respectively. Women (P = 0.02) and those with less experience (P = 0.002) were more concerned about personal barriers. GPs also were more concerned about technical barriers (P = 0.02). According to the study, technical and ethics barriers were considered as the most important barriers however, lack of awareness in target population is also considered as one of the main barriers. Ignoring issues such as personal and ethical barriers, even if the necessary infrastructure and technical requirements were provided, may result in failure. Therefore, along with the creating infrastructure and resolving organizational barriers, special attention to education and awareness of physicians and providing solution for ethics concerns are necessary.

Keywords: barriers, development health information systems, implementation, physicians

Procedia PDF Downloads 346
348 Mechanical Properties of Enset Fibers Obtained from Different Breeds of Enset Plant

Authors: Diriba T. Balcha, Boris Kulig, Oliver Hensel, Eyassu Woldesenbet

Abstract:

Enset fiber is agricultural waste and available in a surplus amount in Ethiopia. However, the hypothesized variation in properties of this fiber due to diversity of its plant source breed, fiber position within plant stem and chemical treatment duration had not proven that its application for the development of composite products is problematic. Currently, limited data are known on the functional properties of the fiber as a potential functional fiber. Thus, an effort is made in this study to narrow the knowledge gaps by characterizing it. The experimental design was conducted using Design-Expert software and the tensile test was conducted on Enset fiber from 10 breeds: Dego, Dirbo, Gishera, Itine, Siskela, Neciho, Yesherkinke, Tuzuma, Ankogena, and Kucharkia. The effects of 5% Na-OH surface treatment duration and fiber location along and across the plant pseudostem was also investigated. The test result shows that the rupture stress variation is not significant among the fibers from 10 Enset breeds. However, strain variation is significant among the fibers from 10 Enset breeds that breed Dego fiber has the highest strain before failure. Surface treated fibers showed improved rupture strength and elastic modulus per 24 hours of treatment duration. Also, the result showed that chemical treatment can deteriorate the load-bearing capacity of the fiber. The raw fiber has the higher load-bearing capacity than the treated fiber. And, it was noted that both the rupture stress and strain increase in the top to bottom gradient, whereas there is no significant variation across the stem. Elastic modulus variation both along and across the stem was insignificant. The rupture stress, elastic modulus, and strain result of Enset fiber are 360.11 ± 181.86 MPa, 12.80 ± 6.85 GPa and 0.04 ± 0.02 mm/mm, respectively. These results show that Enset fiber is comparable to other natural fibers such as abaca, banana, and sisal fibers and can be used as alternatives natural fiber for composites application. Besides, the insignificant variation of properties among breeds and across stem is essential for all breeds and all leaf sheath of the Enset fiber plant for fiber extraction. The use of short natural fiber over the long is preferable to reduce the significant variation of properties along the stem or fiber direction. In conclusion, Enset fiber application for composite product design and development is mechanically feasible.

Keywords: Agricultural waste, Chemical treatment, Fiber characteristics, Natural fiber

Procedia PDF Downloads 238
347 The Use of Random Set Method in Reliability Analysis of Deep Excavations

Authors: Arefeh Arabaninezhad, Ali Fakher

Abstract:

Since the deterministic analysis methods fail to take system uncertainties into account, probabilistic and non-probabilistic methods are suggested. Geotechnical analyses are used to determine the stress and deformation caused by construction; accordingly, many input variables which depend on ground behavior are required for geotechnical analyses. The Random Set approach is an applicable reliability analysis method when comprehensive sources of information are not available. Using Random Set method, with relatively small number of simulations compared to fully probabilistic methods, smooth extremes on system responses are obtained. Therefore random set approach has been proposed for reliability analysis in geotechnical problems. In the present study, the application of random set method in reliability analysis of deep excavations is investigated through three deep excavation projects which were monitored during the excavating process. A finite element code is utilized for numerical modeling. Two expected ranges, from different sources of information, are established for each input variable, and a specific probability assignment is defined for each range. To determine the most influential input variables and subsequently reducing the number of required finite element calculations, sensitivity analysis is carried out. Input data for finite element model are obtained by combining the upper and lower bounds of the input variables. The relevant probability share of each finite element calculation is determined considering the probability assigned to input variables present in these combinations. Horizontal displacement of the top point of excavation is considered as the main response of the system. The result of reliability analysis for each intended deep excavation is presented by constructing the Belief and Plausibility distribution function (i.e. lower and upper bounds) of system response obtained from deterministic finite element calculations. To evaluate the quality of input variables as well as applied reliability analysis method, the range of displacements extracted from models has been compared to the in situ measurements and good agreement is observed. The comparison also showed that Random Set Finite Element Method applies to estimate the horizontal displacement of the top point of deep excavation. Finally, the probability of failure or unsatisfactory performance of the system is evaluated by comparing the threshold displacement with reliability analysis results.

Keywords: deep excavation, random set finite element method, reliability analysis, uncertainty

Procedia PDF Downloads 268