Search results for: indoor/outdoor air pollution
2314 Assessment of Air Pollution Impacts On Population Health in Béjaia City
Authors: Benaissa Fatima, Alkama Rezak, Annesi-Maesano Isabella
Abstract:
To assess the health impact of the air pollution on the population of Béjaia, we carried out a descriptive epidemiologic inquiry near the medical establishments of three areas. From the registers of hospital admissions, we collected data on the hospital mortality and admissions relating to the various cardiorespiratory pathologies generated by this type of pollution. In parallel, data on the automobile fleet of Bejaia and other measurements were exploited to show that the concentrations of the pollutants are strongly correlated with the concentration the urban traffic. This study revealed that the whole of the population is touched, but the sensitivity to pollution can show variations according to the age, the sex and the place of residence. So the under population of the town of Bejaia marked the most raised death and morbidity rates, followed that of Kherrata. Weak rates are recorded for under rural population of Feraoun. This approach enables us to conclude that the population of Béjaia could not escape the urban pollution generated by her old automobile fleet. To install a monitoring and measuring site of the air pollution in this city could provide a beneficial tool to protect its inhabitants by them informing on quality from the air that they breathe and measurements to follow to minimize the impacts on their health and by alerting the authorities during the critical situations.Keywords: air, urban pollution, health, impacts
Procedia PDF Downloads 3602313 Flashover Voltage of Silicone Insulating Surface Covered by Water Drops under AC Voltage
Authors: Fatiha Aouabed, Abdelhafid Bayadi, Rabah Boudissa
Abstract:
Nowadays, silicone rubber insulation materials are widely used in high voltage outdoor insulation systems as they can combat pollution flashover problems. The difference in pollution flashover performance of silicone rubber and other insulating materials is due to the way that water wets their surfaces. It resides as discrete drops on silicone rubber, and the mechanism of flashover is due to the breakdown of the air between the water drops and the distortion of these drops in the direction of the electric field which brings the insulation to degradation and failure. The main objective of this work is to quantify the effect of different types of water drops arrangements, their position and dry bands width on the flashover voltage of the silicone insulating surface with non-uniform electric field systems. The tests were carried out on a rectangular sample under AC voltage. A rod-rod electrode system is used. The findings of this work indicate that the performance of the samples decreases with the presence of water drops on their surfaces. Further, these experimental findings show that there is a limiting number of rows from which the flashover voltage of the insulation is minimal and constant. This minimum is a function of the distance between two successive rows. Finally, it is concluded that the system withstand voltage increases when the row of droplets on the electrode axis is removed.Keywords: contamination, flashover, testing, silicone rubber insulators, surface wettability, water droplets
Procedia PDF Downloads 4422312 Assessing the Severity of Traffic Related Air Pollution in South-East London to School Pupils
Authors: Ho Yin Wickson Cheung, Liora Malki-Epshtein
Abstract:
Outdoor air pollution presents a significant challenge for public health globally, especially in urban areas, with road traffic acting as the primary contributor to air pollution. Several studies have documented the antagonistic relation between traffic-related air pollution (TRAP) and the impact on health, especially to the vulnerable group of population, particularly young pupils. Generally, TRAP could cause damage to their brain, restricting the ability of children to learn and, more importantly, causing detrimental respiratory issues in later life. Butlittle is known about the specific exposure of children at school during the school day and the impact this may have on their overall exposure to pollution at a crucial time in their development. This project has set out to examine the air quality across primary schools in South-East London and assesses the variability of data found based on their geographic location and surroundings. Nitrogen dioxide, PM contaminants, and carbon dioxide were collected with diffusion tubes and portable monitoring equipment for eight schools across three local areas, that are Greenwich, Lewisham, and Tower Hamlets. This study first examines the geographical features of the schools surrounding (E.g., coverage of urban road structure and green infrastructure), then utilize three different methods to capture pollutants data. Moreover, comparing the obtained results with existing data from monitoring stations to understand the differences in air quality before and during the pandemic. Furthermore, most studies in this field have unfortunately neglected human exposure to pollutants and calculated based on values from fixed monitoring stations. Therefore, this paper introduces an alternative approach by calculating human exposure to air pollution from real-time data obtained when commuting within related areas (Driving routes and field walking). It is found that schools located highly close to motorways are generally not suffering from the most air pollution contaminants. Instead, one with the worst traffic congested routes nearby might also result in poor air quality. Monitored results also indicate that the annual air pollution values have slightly decreased during the pandemic. However, the majority of the data is currently still exceeding the WHO guidelines. Finally, the total human exposures for NO2 during commuting in the two selected routes were calculated. Results illustrated the total exposure for route 1 were 21,730 μm/m3 and 28,378.32 μm/m3, and for route 2 were 30,672 μm/m3 and 16,473 μm/m3. The variance that occurred might be due to the difference in traffic volume that requires further research. Exposure for NO2 during commuting was plotted with detailed timesteps that have shown their peak usually occurred while commuting. These have consolidated the initial assumption to the extremeness of TRAP. To conclude, this paper has yielded significant benefits to understanding air quality across schools in London with the new approach of capturing human exposure (Driving routes). Confirming the severity of air pollution and promoting the necessity of considering environmental sustainability for policymakers during decision making to protect society's future pillars.Keywords: air pollution, schools, pupils, congestion
Procedia PDF Downloads 1172311 Spatial Variability of Soil Pollution and Health Risks Due to Long-Term Wastewater Irrigation in Egypt
Authors: Mohamed Eladham Fadl M. E. Fadl
Abstract:
In Egypt, wastewater has been used for irrigation in areas with fresh water scarcity. However, continuous applications may cause potential risks. Thus, the current study aims at screening the impacts of long-term wastewater irrigation on soil pollution and human health due to the exposure of heavy metals. Soils of nine sites in Al-Qalyubiyah Governorate, Egypt were sampled and analyzed for different properties. Wastewater resulted in a build-up of metals in soils. The pollution index (PI) showed the order of Cd > Pb > Ni > Zn. The integrated pollution index of Nemerow’s (IPIN) exceeded the safe limit of 0.7. The enrichment factor (EF) surpassed 1.0 value proving anthropogenic effects. The geo-accumulation index (Igeo) indicated that Pb, Ni, and Zn-induced none to moderate pollution, while high threats were associated with Cd. The calculated hazard index proved a potential health risk for humans, particularly children. It is recommended to perform a treatment to the wastewater used in irrigation to avoid such threats.Keywords: pollution, health risks, heavy metals, effluent, irrigation, GIS techniques
Procedia PDF Downloads 3382310 An Analysis of Structural Relationship among Perceived Restorative Environment, Relaxing Experience, Subjective Vitality and the Health-Related Quality of Life of the Participants in Nature-Based Urban Outdoor Recreation
Authors: Lee Jin-Eui, Kim Jin-OK, Han Seung-Hoon, Kim Nam-Jo
Abstract:
Recently, there has been a growing interest in wellbeing where individuals pursue a healthy life. About the half of world population is living in cities, and the urban environment is negatively affecting the mental health of modern people. The stress level of urban dwellers continues to increase, and they pursue nature-based recreation activities to relieve their stresses. It was found that activities in green spaces are improving concentration, relieving mental stress, and positively affecting physical activities and social relationship, thus enhancing the quality of life. For that reason, studies have been continuously conducted on the role of nature, which is a green space for pursuing health and relieving the stress of urban dwellers. Therefore, this study investigated the effect of experiencing a restoration from nature-based outdoor recreation activities of urban dwellers on their quality of life for the groups with high and low-stress levels. The results of the analysis against visitors who trekked and climbed Mt. Bukhan National Park in Seoul, South Korea showed that the effect of perceiving restorative environment on relaxation, calmness and subjective vitality, and the effect of relaxation and calmness on the quality of life were similar in both groups. However, it was found that subjective vitality affected the quality of life in the group with the high-stress group, while it did not show a significant result in the low-stress group. This is because the high-stress group increased their belief in the future and themselves and vitality through nature-based outdoor activities, which in turn affected their quality of life, while people in the low-stress group normally have subjective vitality in their daily lives, not affected by nature-based outdoor recreation. This result suggests that urban dwellers feel relaxed and calm through nature-based outdoor recreation activities with perceived restorative environment, and such activities enhance their quality of life. Therefore, a wellbeing policy is needed to enhance the quality of life of citizens by creating green spaces in city centers for the promotion of public health.Keywords: healing tourism, nature-based outdoor recreation, perceived restorative environment, quality of life
Procedia PDF Downloads 2192309 Intelligent Rescheduling Trains for Air Pollution Management
Authors: Kainat Affrin, P. Reshma, G. Narendra Kumar
Abstract:
Optimization of timetable is the need of the day for the rescheduling and routing of trains in real time. Trains are scheduled in parallel with the road transport vehicles to the same destination. As the number of trains is restricted due to single track, customers usually opt for road transport to use frequently. The air pollution increases as the density of vehicles on road transport is increased. Use of an alternate mode of transport like train helps in reducing air-pollution. This paper mainly aims at attracting the passengers to Train transport by proper rescheduling of trains using hybrid of stop-skip algorithm and iterative convex programming algorithm. Rescheduling of train bi-directionally is achieved on a single track with dynamic dual time and varying stops. Introduction of more trains attract customers to use rail transport frequently, thereby decreasing the pollution. The results are simulated using Network Simulator (NS-2).Keywords: air pollution, AODV, re-scheduling, WSNs
Procedia PDF Downloads 3602308 Urban Block Design's Impact on the Indoor Daylight Quality, Heating and Cooling Loads of Buildings in the Semi-Arid Regions: Duhok City in Kurdistan Region-Iraq as a Case Study
Authors: Kawar Salih
Abstract:
It has been proven that designing sustainable buildings starts from early stages of urban design. The design of urban blocks specifically, is considered as one of the pragmatic strategies of sustainable urbanism. There have been previous studies that focused on the impact of urban block design and regulation on the outdoor thermal comfort in the semi-arid regions. However, no studies have been found that concentrated on that impact on the internal behavior of buildings of those regions specifically the daylight quality and energy performance. Further, most studies on semi-arid regions are focusing only on the cooling load reduction, neglecting the heating load. The study has focused on two parameters of urban block distribution which are the block orientation and the surface-to-volume ratio with the consideration of both heating and cooling loads of buildings. In Duhok (a semi-arid city in Kurdistan region of Iraq), energy consumption and daylight quality of different types of residential blocks have been examined using dynamic simulation. The findings suggest that there is a considerable higher energy load for heating than cooling, contradicting many previous studies about these regions. The results also highlight that the orientation of urban blocks can vary the energy consumption to 8%. Regarding the surface-to-volume ratio (S/V), it was observed that after the twice enlargement of the S/V, the energy consumption increased 15%. Though, the study demonstrates as well that there are opportunities for reducing energy consumption with the increase of the S/V which contradicts many previous research on S/V impacts on energy consumption. These results can help to design urban blocks with the bigger S/V than existing blocks in the city which it can provide better indoor daylight and relatively similar energy consumption.Keywords: blocke orienation, building energy consumption, urban block design, semi-arid regions, surfacet-to-volume ratio
Procedia PDF Downloads 3612307 Comparison of Concentration of Heavy Metals in PM2.5 Analyzed in Three Different Global Research Institutions Using X-Ray Fluorescence
Authors: Sungroul Kim, Yeonjin Kim
Abstract:
This study was conducted by comparing the concentrations of heavy metals analyzed from the same samples with three X-Ray fluorescence (XRF) spectrometer in three different global research institutions, including PAN (A Branch of Malvern Panalytical, Seoul, South Korea), RTI (Research Triangle Institute, NC, U.S.A), and aerosol laboratory in Harvard University, Boston, U.S.A. To achieve our research objectives, the indoor air filter samples were collected at homes (n=24) of adults or child asthmatics then analyzed in PAN followed by Harvard University and RTI consecutively. Descriptive statistics were conducted for data comparison as well as correlation and simple regression analysis using R version 4.0.3. As a result, detection rates of most heavy metals analyzed in three institutions were about 90%. Of the 25 elements commonly analyzed among those institutions, 16 elements showed an R² (coefficient of determination) of 0.7 or higher (10 components were 0.9 or higher). The findings of this study demonstrated that XRF was a useful device ensuring reproducibility and compatibility for measuring heavy metals in PM2.5 collected from indoor air of asthmatics’ home.Keywords: heavy metals, indoor air quality, PM2.5, X-ray fluorescence
Procedia PDF Downloads 2002306 Time Series Analysis of Radon Concentration at Different Depths in an Underground Goldmine
Authors: Theophilus Adjirackor, Frederic Sam, Irene Opoku-Ntim, David Okoh Kpeglo, Prince K. Gyekye, Frank K. Quashie, Kofi Ofori
Abstract:
Indoor radon concentrations were collected monthly over a period of one year in 10 different levels in an underground goldmine, and the data was analyzed using a four-moving average time series to determine the relationship between the depths of the underground mine and the indoor radon concentration. The detectors were installed in batches within four quarters. The measurements were carried out using LR115 solid-state nuclear track detectors. Statistical models are applied in the prediction and analysis of the radon concentration at various depths. The time series model predicted a positive relationship between the depth of the underground mine and the indoor radon concentration. Thus, elevated radon concentrations are expected at deeper levels of the underground mine, but the relationship was insignificant at the 5% level of significance with a negative adjusted R2 (R2 = – 0.021) due to an appropriate engineering and adequate ventilation rate in the underground mine.Keywords: LR115, radon concentration, rime series, underground goldmine
Procedia PDF Downloads 452305 Respiratory Health and Air Movement Within Equine Indoor Arenas
Authors: Staci McGill, Morgan Hayes, Robert Coleman, Kimberly Tumlin
Abstract:
The interaction and relationships between horses and humans have been shown to be positive for physical, mental, and emotional wellbeing, however equine spaces where these interactions occur do include some environmental risks. There are 1.7 million jobs associated with the equine industry in the United States in addition to recreational riders, owners, and volunteers who interact with horses for substantial amounts of time daily inside built structures. One specialized facility, an “indoor arena” is a semi-indoor structure used for exercising horses and exhibiting skills during competitive events. Typically, indoor arenas have a sand or sand mixture as the footing or surface over which the horse travels, and increasingly, silica sand is being recommended due to its durable nature. It was previously identified in a semi-qualitative survey that the majority of individuals using indoor arenas have environmental concerns with dust. 27% (90/333) of respondents reported respiratory issues or allergy-like symptoms while riding with 21.6% (71/329) of respondents reporting these issues while standing on the ground observing or teaching. Frequent headaches and/or lightheadedness was reported in 9.9% (33/333) of respondents while riding and in 4.3% 14/329 while on the ground. Horse respiratory health is also negatively impacted with 58% (194/333) of respondents indicating horses cough during or after time in the indoor arena. Instructors who spent time in indoor arenas self-reported more respiratory issues than those individuals who identified as smokers, highlighting the health relevance of understanding these unique structures. To further elucidate environmental concerns and self-reported health issues, 35 facility assessments were conducted in a cross-sectional sampling design in the states of Kentucky and Ohio (USA). Data, including air speeds, were collected in a grid fashion at 15 points within the indoor arenas and then mapped spatially using krigging in ARCGIS. From the spatial maps, standard variances were obtained and differences were analyzed using multivariant analysis of variances (MANOVA) and analysis of variances (ANOVA). There were no differences for the variance of the air speeds in the spaces for facility orientation, presence and type of roof ventilation, climate control systems, amount of openings, or use of fans. Variability of the air speeds in the indoor arenas was 0.25 or less. Further analysis yielded that average air speeds within the indoor arenas were lower than 100 ft/min (0.51 m/s) which is considered still air in other animal facilities. The lack of air movement means that dust clearance is reliant on particle size and weight rather than ventilation. While further work on respirable dust is necessary, this characterization of the semi-indoor environment where animals and humans interact indicates insufficient air flow to eliminate or reduce respiratory hazards. Finally, engineering solutions to address air movement deficiencies within indoor arenas or mitigate particulate matter are critical to ensuring exposures do not lead to adverse health outcomes for equine professionals, volunteers, participants, and horses within these spaces.Keywords: equine, indoor arena, ventilation, particulate matter, respiratory health
Procedia PDF Downloads 1162304 Analysis of the Air Pollution Behavior Registered at MACAM Net Using DOAS, Associated with High Pollution Episodes
Authors: Francisca Rojas Martínez, T. Pedro Oyola
Abstract:
The combination of the geographical and meteorological conditions of the Santiago basin are unfavorable for the circulation of atmospheric pollution, especially in the autumn and winter months. The problem of environmental pollution in the Metropolitan Region has been studied since the 1960s because the city has presented high pollution levels for most of the year, levels that have even been compared with those in cities in developed countries, This implies serious consequences for the health of the population. Two of the most important gasses present in the contamination are NO2, and O3, the highest concentrations of nitrogen dioxide are measured during the winter, in addition, it is considered as a great contribution to the fine fraction of particulate matter and as a precursor of tropospheric ozone. On the other hand, tropospheric ozone is a pollutant of photochemical origin and is strongly enhanced by solar radiation, which is why its presence in the atmosphere is more significant in the spring and summer. The measurements were made at 3 different places in Santiago, and were used different equipment; a DOAS for gasses measures, SIMCA for Black Carbon Measure and the MACAM net for particulate matter and meteorological condition. The results shows an important relation between height and presence of pollution gasses, and additionally, pollution episodes are in common low temperature (< 10 °C) and high relative humidity (> 80%), which are factors that allows the air suspension of particulate matter and focus NH4+ and NO3-.Keywords: black carbon, DOAS, episodes, high pollution, simca
Procedia PDF Downloads 2772303 Environmental Pollution and Treatment Technology
Authors: R. Berrached, H. Ait Mahamed, A. Iddou
Abstract:
Water pollution is nowadays a serious problem, due to the increasing scarcity of water and thus to the impact induced by such pollution on the human health. Various techniques are made use of to deal with water pollution. Among the most used ones, some can be enumerated: the bacterian bed, the activated mud, the Lagunage as biological processes and coagulation-floculation as a physic-chemical process. These processes are very expensive and an treatment efficiency which decreases along with the increase of the initial pollutants’ concentration. This is the reason why research has been reoriented towards the use of a process by adsorption as an alternative solution instead of the other traditional processes. In our study, we have tempted to exploit the characteristics of two metallic hydroxides Al and Fe to purify contaminated water by two industrial dyes SBL blue and SRL-150 orange. Results have shown the efficiency of the two materials on the blue SBL dye.Keywords: metallic hydroxydes, industrial dyes, purificatıon,
Procedia PDF Downloads 3252302 Impact of Chronic Pollution on the Taj Mahal, India
Authors: Kiran P. Chadayamuri, Saransh Bagdi, Sai Vinod Boddu
Abstract:
Pollution has been a major problem that has haunted India for years. Large amounts of industrial, automobile and domestic waste have resulted in heavy contamination of air, land and water. The Taj Mahal, one of the Seven Wonders of the World, has been and continues to be India’s symbol of a rich history around the globe. Over the years, the beauty of Taj Mahal has also suffered from increasing pollution. Its shiny white exterior has started to turn yellow because of air pollution and acid rain. Illegal factories and uncontrolled construction have played a major role in worsening its condition. Rapid population growth in the city (Agra) meant more water requirement which has led to ground water deterioration under the historical monument making its wooden foundations dry and weak. Despite various measures by the state and central government, there hasn’t been any satisfactory result. This paper aims at studying the various causes and their impacts affecting the Taj Mahal and method that could slow down its deterioration.Keywords: pollution, Taj Mahal, India, management
Procedia PDF Downloads 3912301 Air Pollutants Exposure and Blood High Sensitivity C-Reactive Protein Concentrations in Healthy Pregnant Women
Authors: Gwo-Hwa Wan, Tai-Ho Hung, Fen-Fang Chung, Wan-Ying Lee, Hui-Ching Yang
Abstract:
Air pollutant exposure results in elevated concentrations of oxidative stress and inflammatory biomarkers in general populations. Increased concentrations of inflammatory biomarkers in pregnant women would be associated with preterm labor and low birth weight. To our best knowledge, the associations between air pollutants exposure and inflammation in pregnant women and fetuses are unknown, as well as their effects on fetal growth. This study aimed to evaluate the influences of outdoor air pollutants in northern Taiwan areas on the inflammatory biomarker (high sensitivity C-reactive protein, hs-CRP) concentration in the blood of healthy pregnant women and how the biomarker impacts fetal growth. In this study, 38 healthy pregnant women who are in their first trimester and live in northern Taiwan area were recruited from the Taipei Chang Gung Memorial Hospital. Personal characteristics and prenatal examination data (e.g., blood pressure) were obtained from recruited subjects. The concentrations of inflammatory mediators, hs-CRP, in the blood of healthy pregnant women were analyzed. Additionally, hourly data of air pollutants (PM10, SO2, NO2, O3, CO) concentrations were obtained from air quality monitoring stations in Taipei area, established by the Taiwan Environmental Protection Administration. The definition of lag 0 and lag 01 are the exposure to air pollutants on the day of blood withdrawal, and the average exposure to air pollutants one day before and on the day of blood withdrawal, respectively. The statistical analyses were conducted using SPSS software version 22.0 (SPSS, Inc., Chicago, IL, USA). This analytical result indicates that the healthy pregnant women aged between 28 and 42 years old. The body mass index before pregnancy averaged 21.51 (sd = 2.51) kg/m2. Around 90% of the pregnant women had never smoking habit, and 28.95% of them had allergic diseases. Approximately around 84% and 5.26% of the pregnant women worked at indoor and outdoor environments, respectively. The mean hematocrit level of the pregnant women was 37.10%, and the hemoglobin levels were ranged between 10.1 and 14.7 g/dL with 12.47 g/dL of mean value. The blood hs-CRP concentrations of healthy pregnant women in the first trimester ranged between 0.32 and 32.5 mg/L with 2.83 (sd = 5.69) mg/L of mean value. The blood hs-CRP concentrations were positively associated with ozone concentrations at lag 0-14 (r = 0.481, p = 0.017) in healthy pregnant women. Significant lag effects were identified in ozone at lag 0-14 with a positive excess concentration of blood hs-CRP.Keywords: air pollutant, hs-CRP, pregnant woman, ozone, first trimester
Procedia PDF Downloads 2562300 Effect of Urban Informal Settlements and Outdoor Advertisement on the Quality of Built Environment and Urban Upgrading in Nigeria
Authors: Amao Funmilayo Lanrewaju, T. Ogunlade
Abstract:
The paper examines the causes and characteristics of informal settlements and outdoor advertisement in the evaluation of quality of environment. The paper identifies the problems that have aided informal settlements to: Urbanization, poverty, growth of informal sector, non-affordability of land and housing shortage. The paper asserts that the informal settlements have serious adverse effects on the people’s health, their built environment and quality of life. The secondary data was obtained from books, journals and seminar papers. The paper argues that, although the urban upgrading possesses great potential for improving quality of built environment in informal settlements, there is a need to repackage the upgrading exercise so that majority can benefit from it. It is necessary to incorporate community participation into the urban upgrading in order to assist the very poor that cannot take care of their housing consumption needs. Therefore, government is encouraged to see informal settlements as a solution to new city planning rather than problem to the urban areas. This paper suggests the implementation of policies and planning, physical infrastructural development, social economic improvement, environment and health improvement. Government, private and communities interventions on informal settlements are required in order to prevent further decay for sustainable development.Keywords: quality of environment, informal settlements, urban upgrading, outdoor advertisement
Procedia PDF Downloads 4852299 Indoor Air Assessment and Health Risk of Volatile Organic Compounds in Secondary School Classrooms in Benin City, Edo State, Nigeria
Authors: Osayomwanbor E. Oghama, John O. Olomukoro
Abstract:
The school environment, apart from home, is probably the most important indoor environment for children. Children spend as much as 80-90% of their indoor time either at school or at home; an average of 35 - 40 hours per week in schools, hence are at the risk of indoor air pollutants such as volatile organic compounds (VOCs). Concentrations of VOCs vary widely but are generally higher indoors than outdoors. This research was, therefore, carried out to evaluate the levels of VOCs in secondary school classrooms in Benin City, Edo State. Samples were obtained from a total of 18 classrooms in 6 secondary schools. Samples were collected 3 times from each school and from 3 different classrooms in each school using Draeger ORSA 5 tubes. Samplers were left to stay for a school-week (5 days). The VOCs detected and analyzed were benzene, ethlybenzene, isopropylbenzene, naphthalene, n-butylbenzene, n-propylbenzene, toluene, m-xylene, p-xylene, o-xylene, styrene, chlorobenzene, chloroform, 1,2-dichloropropane, 2,2-dichloropropane, tetrachloroethane, tetrahydrofuran, isopropyl acetate, α-pinene, and camphene. The results showed that chloroform, o-xylene, and styrene were the most abundant while α-pinene and camphene were the least abundant. The health risk assessment was done in terms of carcinogenic (CRI) and non-carcinogenic risks (THR). The CRI values of the schools ranged from 1.03 × 10-5 to 1.36 × 10-5 μg/m³ (a mean of 1.16 × 10-5 μg/m³) with School 6 and School 3 having the highest and lowest values respectively. The THR values of the study schools ranged from 0.071-0.086 μg/m³ (a mean of 0.078 μg/m³) with School 3 and School 2 having the highest and lowest values respectively. The results show that all the schools pose a potential carcinogenic risks having CRI values greater than the recommended limit of 1 × 10-6 µg/m³ and no non-carcinogenic risk having THR values less than the USEPA hazard quotient of 1 µg/m³. It is recommended that school authorities should ensure adequate ventilation in their schools, supplementing natural ventilation with mechanical sources, where necessary. In addition, indoor air quality should be taken into consideration in the design and construction of classrooms.Keywords: carcinogenic risk indicator, health risk, indoor air, non-carcinogenic risk indicator, secondary schools, volatile organic compounds
Procedia PDF Downloads 1912298 Simulation-Based Evaluation of Indoor Air Quality and Comfort Control in Non-Residential Buildings
Authors: Torsten Schwan, Rene Unger
Abstract:
Simulation of thermal and electrical building performance more and more becomes part of an integrative planning process. Increasing requirements on energy efficiency, the integration of volatile renewable energy, smart control and storage management often cause tremendous challenges for building engineers and architects. This mainly affects commercial or non-residential buildings. Their energy consumption characteristics significantly distinguish from residential ones. This work focuses on the many-objective optimization problem indoor air quality and comfort, especially in non-residential buildings. Based on a brief description of intermediate dependencies between different requirements on indoor air treatment it extends existing Modelica-based building physics models with additional system states to adequately represent indoor air conditions. Interfaces to corresponding HVAC (heating, ventilation, and air conditioning) system and control models enable closed-loop analyzes of occupants' requirements and energy efficiency as well as profitableness aspects. A complex application scenario of a nearly-zero-energy school building shows advantages of presented evaluation process for engineers and architects. This way, clear identification of air quality requirements in individual rooms together with realistic model-based description of occupants' behavior helps to optimize HVAC system already in early design stages. Building planning processes can be highly improved and accelerated by increasing integration of advanced simulation methods. Those methods mainly provide suitable answers on engineers' and architects' questions regarding more exuberant and complex variety of suitable energy supply solutions.Keywords: indoor air quality, dynamic simulation, energy efficient control, non-residential buildings
Procedia PDF Downloads 2322297 Spatial Orientation of Land Use Activities along Buffalo River Estuary: A Study in Buffalo City Metropolitan Municipality, Eastern Cape South Africa
Authors: A. Ngunga, M. K. Soviti, S. Nakin
Abstract:
South Africa is one of the developing countries rich in estuary ecosystem. Previous studies have identified many impacts of land use activities on the pollution status of the estuaries. These land use activity and related practices are often blamed for the many pollution problems affecting the estuaries. For example, the estuarine ecosystems on a global scale are experiencing vast transformations from anthropogenic influences; Buffalo River Estuary is one of the influenced estuaries whereby the sources of pollution are unknown. These problems consequently lead to the degradation of the estuaries. The aim of the research was to establish the factors that have the potential to impact pollution status of Buffalo river estuary. Study focuses on Identifying and mapping land use activities along Buffalo River Estuary. Questionnaire survey, structured interviews, direct observation, GPS survey and ArcGIS mapping were the methods used for data collection in the area, and results were analyzed and presented by ANOVA and Microsoft Excel statistical methods. The results showed that harbour is the main source of pollution, in Buffalo River Estuary, through Ballast water discharge. Therefore that requires more concern for protecting and cleaning the estuary.Keywords: estuary, land-use activities, pollution, mapping, water pollution
Procedia PDF Downloads 1942296 Cellular Architecture of Future Wireless Communication Networks
Authors: Mohammad Yahaghifar
Abstract:
Nowadays Wireless system designers have been facing the continuously increasing demand for high data rates and mobility required by new wireless applications. Evolving future communication network generation cellular wireless networks are envisioned to overcome the fundamental challenges of existing cellular networks, for example, higher data rates, excellent end-to-end performance, and user coverage in hot-spots and crowded areas with lower latency,energy consumption and cost per information transfer. In this paper we propose a potential cellular architecture that separates indoor and outdoor scenarios and discuss various promising technologies for future wireless communication systemssystems, such as massive MIMO, energy-efficient communications,cognitive radio networks, and visible light communications and we disscuse about 5G that is next generation of wireless networks.Keywords: future challenges in networks, cellur architecture, visible light communication, 5G wireless technologies, spatial modulation, massiva mimo, cognitive radio network, green communications
Procedia PDF Downloads 4882295 Computational Modeling of Thermal Comfort and CO2 Distribution in Common Room-Lecture Room by Using Hybrid Air Ventilation System, Thermoelectric-PV-Silica Gel under IAQ Standard
Authors: Jirod Chaisan, Somchai Maneewan, Chantana Punlek, Ninnart Rachapradit, Surapong Chirarattananon, Pattana Rakkwamsuk
Abstract:
In this paper, simulation modeling of heat transfer, air flow and distribution emitted from CO2 was performed in a regenerated air. The study room was divided in 3 types: common room, small lecture room and large lecture room under evaluated condition in two case: released and unreleased CO2 including of used hybrid air ventilation system for regenerated air under Thailand climate conditions. The carbon dioxide was located on the center of the room and released rate approximately 900-1200 ppm corresponded with indoor air quality standard (IAQs). The indoor air in the thermal comfort zone was calculated and simulated with the numerical method that using real data from the handbook guideline. The results of the study showed that in the case of hybrid air ventilation system explained thermal and CO2 distribution due to the system was adapted significantly in the comfort zone. The results showed that when CO2 released on the center of the other room, the CO2 high concentration in comfort zone so used hybrid air ventilation that decreased CO2 with regeneration air including of reduced temperature indoor. However, the study is simulation modeling and guideline only so the future should be the experiment of hybrid air ventilation system for evaluated comparison of the systems.Keywords: air ventilation, indoor air quality, thermal comfort, thermoelectric, photovoltaic, dehumidify
Procedia PDF Downloads 4842294 The Role of Phytoremediation in Reclamation of Soil Pollution and Suitability of Certain Ornamental Plants to Phytoremediation
Authors: Bahriye Gülgün, Gökhan Balik, Şükrü Dursun, Kübra Yazici
Abstract:
The main reasons such as economic growth of society increase of the world population and rapid changes of industrialization cause the amount and the types of pollutants to increase over time. Soil pollution is the typical side effect of industrial activities. As a result of industrial activities, there are large amounts of heavy metal emission every year. Heavy metals are one of the highest pollution sources according to the soil pollution aspect. The usage of hyperaccumulator plants to clean heavy metal polluted soils and the selection of plants for phytoremediation gain importance recently. There are limited numbers of researches on the ornamental plant types of phytoremediation thus; researches on this subject are important. This research is prepared based on the ornamental plant types with phytoremediation abilities.Keywords: phytoremediation, ornamental plants, landscape reclamation, soil reclamation, environmental pollution
Procedia PDF Downloads 4102293 Accurate Positioning Method of Indoor Plastering Robot Based on Line Laser
Authors: Guanqiao Wang, Hongyang Yu
Abstract:
There is a lot of repetitive work in the traditional construction industry. These repetitive tasks can significantly improve production efficiency by replacing manual tasks with robots. There- fore, robots appear more and more frequently in the construction industry. Navigation and positioning are very important tasks for construction robots, and the requirements for accuracy of positioning are very high. Traditional indoor robots mainly use radiofrequency or vision methods for positioning. Compared with ordinary robots, the indoor plastering robot needs to be positioned closer to the wall for wall plastering, so the requirements for construction positioning accuracy are higher, and the traditional navigation positioning method has a large error, which will cause the robot to move. Without the exact position, the wall cannot be plastered, or the error of plastering the wall is large. A new positioning method is proposed, which is assisted by line lasers and uses image processing-based positioning to perform more accurate positioning on the traditional positioning work. In actual work, filter, edge detection, Hough transform and other operations are performed on the images captured by the camera. Each time the position of the laser line is found, it is compared with the standard value, and the position of the robot is moved or rotated to complete the positioning work. The experimental results show that the actual positioning error is reduced to less than 0.5 mm by this accurate positioning method.Keywords: indoor plastering robot, navigation, precise positioning, line laser, image processing
Procedia PDF Downloads 1482292 Heavy Metal Contamination in Sediments of North East Coast of Tamilnadu by EDXRF Technique
Authors: R. Ravisankar, Tholkappian A. Chandrasekaran, Y. Raghu, K. K. Satapathy, M. V. R. Prasad, K. V. Kanagasabapathy
Abstract:
The coastal areas of Tamilnadu are assuming greater importance owing to increasing human population, urbanization and accelerated industrial activities. sIn the present study, sediment samples are collected along the east coast of Tamilnadu for assessment of heavy metal pollution. The concentration of 13 selected heavy metals such as Mg, Al, Si, K, Ca, Ti, Fe, V, Cr, Mn, Co, Ni and Zn determined by Energy dispersive X-ray fluorescence (EDXRF) technique. In order to describe the pollution status, Contamination factor and pollution load index are calculated and reported. This result suggests that sources of metal contamination were mainly attributed to natural inputs from surrounding environments.Keywords: sediments, heavy metals, EDXRF, pollution contamination factors
Procedia PDF Downloads 3402291 Environmental Pollution Impact on Lung Functions and Cognitive Functions Among School Adolescence
Authors: Sultan Ayoub Meo
Abstract:
Environmental pollution is a highly challenging global concern of the 21st century and is a major cause of various communicable and non-communicable diseases. We investigate the impact of air pollution on "lung function, fractional exhaled nitric oxide, and cognitive function"in a group of one hundred young students studying in a traffic-polluted school. The students wereselected based on their age, gender, height, weight, and ethnicity. After the clinical history, one hundred students were recruited from the schoolnear and away from the polluted areas. The lung and cognitive functions were recorded. The results revealed that lung and cognitive function parameters were reduced in groups of students studying in a school located in a traffic-polluted area compared to thosestudying in a schoolsituated away from the traffic-polluted area. Environmental pollution impairs students' lung and cognitive functions studying in schools located within traffic-polluted areas. The health officials and policymakers establish strategies to minimize environmental pollution and its allied health hazards. Prof. Sultan Ayoub Meo, MD, Ph.D Professor, Department of Physiology, College of Medicine, King Saud University, Saudi Arabia Email. [email protected] / [email protected]Keywords: environmental pOllution, lung physiology, cognitive functions, air pollution
Procedia PDF Downloads 1232290 Potential Distribution and Electric Field Analysis around a Polluted Outdoor Polymeric Insulator with Broken Sheds
Authors: Adel Kara, Abdelhafid Bayadi, Hocine Terrab
Abstract:
This paper presents a study of electric field distribution along of 72 kV polymeric outdoor insulators with broken sheds. Different cases of damaged insulators are modeled and both of clean and polluted cases. By 3D finite element analysis using the software package COMSOL Multiphysics 4.3b. The obtained results of potential and the electrical field distribution around insulators by 3D simulation proved that finite element computations is useful tool for studying insulation electrical field distribution.Keywords: electric field distributions, insulator, broken sheds, potential distributions
Procedia PDF Downloads 5122289 LogiSun: An Interactive Robot to Reduce Pollution on the Beach
Authors: Ruth Manzanares, Victor Honores, Hugo Zapata, Javier Cansaya, Deivid Yavar, Junior Meza
Abstract:
LogiSum is a robot focused on education like a solution to the ecological crisis. This robot allows reducing the pollution on the beaches by stimulating environmental awareness of not contaminating through the collection of waste. Through the use of the methodology of design thinking, it is intended to reinforce values in adults and with a greater focus on children, so as not to contaminate the beaches. The goal is to encourage the use of the container of the robot LogiSum to put the garbage, with visual interaction and simulation of dialogue with the function of the robot. The results obtained of the testings of the interaction of children with the robot showed an encouraging behavior. With the robot, children left the waste in the right places and not bury it in the sand or in the floor.Keywords: interaction human-robot, pollution reduction, social robot, robot container, beach pollution
Procedia PDF Downloads 2672288 An Experimental Study on Intellectual Concentration Influenced by Indoor Airflow
Authors: Kyoko Ito, Shinya Furuta, Daisuke Kamihigashi, Kimi Ueda, Hirotake Ishii, Hiroshi Shimoda, Fumiaki Obayashi, Kazuhiro Taniguchi
Abstract:
In order to improve intellectual concentration, few studies have verified the effect of indoor airflow among the thermal environment conditions, and the differences of the season in effects have not been studied. In this study, in order to investigate the influence of the airflow in winter on the intellectual concentration, an evaluation experiment was conducted. In the previous study, an effective airflow in summer was proposed and the improvement of intellectual concentration by evaluation experiment was confirmed. Therefore, an airflow profile in winter was proposed with reference to the airflow profile in summer. The airflows are a combination of a simulative airflow and mild airflow. An experiment has been conducted to investigate the influence of a room airflow in winter on intellectual concentration. As a result of comparison with no airflow condition, no significant difference was found. Based on the results, it is a future task to ask preliminary preference in advance and to establish a mechanism that can provide controllable airflow for each individual, taking into account the preference for airflow to be different for each individual.Keywords: concentration time ratio, CTR, indoor airflow, intellectual concentration, workplace environment
Procedia PDF Downloads 2342287 Evaluation of Traffic Noise Level: A Case Study in Residential Area of Ishbiliyah , Kuwait
Authors: Jamal Almatawah, Hamad Matar, Abdulsalam Altemeemi
Abstract:
The World Health Organization (WHO) has recognized environmental noise as harmful pollution that causes adverse psychosocial and physiologic effects on human health. The motor vehicle is considered to be one of the main source of noise pollution. It is a universal phenomenon, and it has grown to the point that it has become a major concern for both the public and policymakers. The aim of this paper, therefore, is to investigate the Traffic noise levels and the contributing factors that affect its level, such as traffic volume, heavy-vehicle Speed and other metrological factors in Ishbiliyah as a sample of a residential area in Kuwait. Three types of roads were selected in Ishbiliyah expressway, major arterial and collector street. The other source of noise that interferes the traffic noise has also been considered in this study. Traffic noise level is measured and analyzed using the Bruel & Kjaer outdoor sound level meter 2250-L (2250 Light). The Count-Cam2 Video Camera has been used to collect the peak and off-peak traffic count. Ambient Weather WM-5 Handheld Weather Station is used for metrological factors such as temperature, humidity and wind speed. Also, the spot speed was obtained using the radar speed: Decatur Genesis model GHD-KPH. All the measurement has been detected at the same time (simultaneously). The results showed that the traffic noise level is over the allowable limit on all types of roads. The average equivalent noise level (LAeq) for the Expressway, Major arterial and Collector Street was 74.3 dB(A), 70.47 dB(A) and 60.84 dB(A), respectively. In addition, a Positive Correlation coefficient between the traffic noise versus traffic volume and between traffic noise versus 85th percentile speed was obtained. However, there was no significant relation and Metrological factors. Abnormal vehicle noise due to poor maintenance or user-enhanced exhaust noise was found to be one of the highest factors that affected the overall traffic noise reading.Keywords: traffic noise, residential area, pollution, vehicle noise
Procedia PDF Downloads 662286 Next Generation Radiation Risk Assessment and Prediction Tools Generation Applying AI-Machine (Deep) Learning Algorithms
Authors: Selim M. Khan
Abstract:
Indoor air quality is strongly influenced by the presence of radioactive radon (222Rn) gas. Indeed, exposure to high 222Rn concentrations is unequivocally linked to DNA damage and lung cancer and is a worsening issue in North American and European built environments, having increased over time within newer housing stocks as a function of as yet unclear variables. Indoor air radon concentration can be influenced by a wide range of environmental, structural, and behavioral factors. As some of these factors are quantitative while others are qualitative, no single statistical model can determine indoor radon level precisely while simultaneously considering all these variables across a complex and highly diverse dataset. The ability of AI- machine (deep) learning to simultaneously analyze multiple quantitative and qualitative features makes it suitable to predict radon with a high degree of precision. Using Canadian and Swedish long-term indoor air radon exposure data, we are using artificial deep neural network models with random weights and polynomial statistical models in MATLAB to assess and predict radon health risk to human as a function of geospatial, human behavioral, and built environmental metrics. Our initial artificial neural network with random weights model run by sigmoid activation tested different combinations of variables and showed the highest prediction accuracy (>96%) within the reasonable iterations. Here, we present details of these emerging methods and discuss strengths and weaknesses compared to the traditional artificial neural network and statistical methods commonly used to predict indoor air quality in different countries. We propose an artificial deep neural network with random weights as a highly effective method for assessing and predicting indoor radon.Keywords: radon, radiation protection, lung cancer, aI-machine deep learnng, risk assessment, risk prediction, Europe, North America
Procedia PDF Downloads 962285 Existence of Nano-Organic Carbon Particles below the Size Range of 10 nm in the Indoor Air Environment
Authors: Bireswar Paul, Amitava Datta
Abstract:
Indoor air environment is a big concern in the last few decades in the developing countries, with increased focus on monitoring the air quality. In this work, an experimental study has been conducted to establish the existence of carbon nanoparticles below the size range of 10 nm in the non-sooting zone of a LPG/air partially premixed flame. Mainly, four optical techniques, UV absorption spectroscopy, fluorescence spectroscopy, dynamic light scattering and TEM have been used to characterize and measure the size of carbon nanoparticles in the sampled materials collected from the inner surface of the flame front. The existence of the carbon nanoparticles in the sampled material has been confirmed with the typical nature of the absorption and fluorescence spectra already reported in the literature. The band gap energy shows that the particles are made up of three to six aromatic rings. The size measurement by DLS technique also shows that the particles below the size range of 10 nm. The results of DLS are also corroborated by the TEM image of the same material.
Keywords: indoor air, carbon nanoparticle, lpg, partially premixed flame, optical techniques
Procedia PDF Downloads 277