Search results for: endotracheal tubes
221 Adequacy of Second-Generation Laryngeal Mask Airway during Prolonged Abdominal Surgery
Authors: Sukhee Park, Gaab Soo Kim
Abstract:
Purpose: We aimed to evaluate the adequacy of second-generation laryngeal mask airway use during prolonged abdominal surgery in respect of ventilation, oxygenation, postoperative pulmonary complications (PPC), and postoperative non-pulmonary complications on living donor kidney transplant (LDKT) surgery. Methods: In total, 257 recipients who underwent LDKT using either laryngeal mask airway-ProSeal (LMA-P) or endotracheal tube (ETT) were retrospectively analyzed. Arterial partial pressure of carbon dioxide (PaCO2 and ratio of arterial partial pressure of oxygen to fractional inspired oxygen (PFR) during surgery were compared between two groups. In addition, PPC including pulmonary aspiration and postoperative non-pulmonary complications including nausea, vomiting, hoarseness, vocal cord palsy, delirium, and atrial fibrillation were also compared. Results: PaCO2 and PFR during surgery were not significantly different between the two groups. PPC was also not significantly different between the two groups. Interestingly, the incidence of delirium was significantly lower in the LMA-P group than the ETT group (3.0% vs. 10.3%, P = 0.029). Conclusions: During prolonged abdominal surgery such as LDKT, second-generation laryngeal mask airway offers adequate ventilation and oxygenation and can be considered a suitable alternative to ETT.Keywords: laryngeal mask airway, prolonged abdominal surgery, kidney transplantation, postoperative pulmonary complication
Procedia PDF Downloads 148220 Intensification of Heat Transfer Using AL₂O₃-Cu/Water Hybrid Nanofluid in a Circular Duct Using Inserts
Authors: Muluken Biadgelegn Wollele, Mebratu Assaye Mengistu
Abstract:
Nanotechnology has created new opportunities for improving industrial efficiency and performance. One of the proposed approaches to improving the effectiveness of temperature exchangers is the use of nanofluids to improve heat transfer performance. The thermal conductivity of nanoparticles, as well as their size, diameter, and volume concentration, all played a role in influencing the rate of heat transfer. Nanofluids are commonly used in automobiles, energy storage, electronic component cooling, solar absorbers, and nuclear reactors. Convective heat transfer must be improved when designing thermal systems in order to reduce heat exchanger size, weight, and cost. Using roughened surfaces to promote heat transfer has been tried several times. Thus, both active and passive heat transfer methods show potential in terms of heat transfer improvement. There will be an added advantage of enhanced heat transfer due to the two methods adopted; however, pressure drop must be considered during flow. Thus, the current research aims to increase heat transfer by adding a twisted tap insert in a plain tube using a working fluid hybrid nanofluid (Al₂O₃-Cu) with a base fluid of water. A circular duct with inserts, a tube length of 3 meters, a hydraulic diameter of 0.01 meters, and tube walls with a constant heat flux of 20 kW/m² and a twist ratio of 125 was used to investigate Al₂O₃-Cu/H₂O hybrid nanofluid with inserts. The temperature distribution is better than with conventional tube designs due to stronger tangential contact and swirls in the twisted tape. The Nusselt number values of plain twisted tape tubes are 1.5–2.0 percent higher than those of plain tubes. When twisted tape is used instead of plain tube, performance evaluation criteria improve by 1.01 times. A heat exchanger that is useful for a number of heat exchanger applications can be built utilizing a mixed flow of analysis that incorporates passive and active methodologies.Keywords: nanofluids, active method, passive method, Nusselt number, performance evaluation criteria
Procedia PDF Downloads 74219 Open Source Algorithms for 3D Geo-Representation of Subsurface Formations Properties in the Oil and Gas Industry
Authors: Gabriel Quintero
Abstract:
This paper presents the result of the implementation of a series of algorithms intended to be used for representing in most of the 3D geographic software, even Google Earth, the subsurface formations properties combining 2D charts or 3D plots over a 3D background, allowing everyone to use them, no matter the economic size of the company for which they work. Besides the existence of complex and expensive specialized software for modeling subsurface formations based on the same information provided to this one, the use of this open source development shows a higher and easier usability and good results, limiting the rendered properties and polygons to a basic set of charts and tubes.Keywords: chart, earth, formations, subsurface, visualization
Procedia PDF Downloads 442218 Behavioral Study Circumferential and Longitudinal Cracks in a Steel Pipeline X65 and Repair Patch
Authors: Sadok Aboubakr
Abstract:
The mechanical behavior of cracks from several manufacturing defect in an oil pipeline, is characterized by the fact that defects'm taking several forms: circumferential, longitudinal and inclined crack that evolve over time. Increased lifetime of the constructions and in particular cylindrical tubes under internal pressure requires knowledge improving these defects during loading. From this study we simulated various forms of cracking and also their pipeline repair patch.Keywords: stress intensity factor, pressure, Young's modulus, Poisson's ratio, Shear modulus, Longueur du pipeline, the angle of crack, crack length
Procedia PDF Downloads 361217 Numerical Study for Spatial Optimization of DVG for Fin and Tube Heat Exchangers
Authors: Amit Arora, P. M. V. Subbarao, R. S. Agarwal
Abstract:
This study attempts to find promising locations of upwash delta winglets for an inline finned tube heat exchanger. Later, location of winglets that delivers highest improvement in thermal performance is identified. Numerical results clearly showed that optimally located upwash delta winglets not only improved the thermal performance of fin area in tube wake and tubes, but also improved overall thermal performance of heat exchanger.Keywords: apparent friction factor, delta winglet, fin and tube heat exchanger, longitudinal vortices
Procedia PDF Downloads 310216 Investigation for Pixel-Based Accelerated Aging of Large Area Picosecond Photo-Detectors
Authors: I. Tzoka, V. A. Chirayath, A. Brandt, J. Asaadi, Melvin J. Aviles, Stephen Clarke, Stefan Cwik, Michael R. Foley, Cole J. Hamel, Alexey Lyashenko, Michael J. Minot, Mark A. Popecki, Michael E. Stochaj, S. Shin
Abstract:
Micro-channel plate photo-multiplier tubes (MCP-PMTs) have become ubiquitous and are widely considered potential candidates for next generation High Energy Physics experiments due to their picosecond timing resolution, ability to operate in strong magnetic fields, and low noise rates. A key factor that determines the applicability of MCP-PMTs in their lifetime, especially when they are used in high event rate experiments. We have developed a novel method for the investigation of the aging behavior of an MCP-PMT on an accelerated basis. The method involves exposing a localized region of the MCP-PMT to photons at a high repetition rate. This pixel-based method was inspired by earlier results showing that damage to the photocathode of the MCP-PMT occurs primarily at the site of light exposure and that the surrounding region undergoes minimal damage. One advantage of the pixel-based method is that it allows the dynamics of photo-cathode damage to be studied at multiple locations within the same MCP-PMT under different operating conditions. In this work, we use the pixel-based accelerated lifetime test to investigate the aging behavior of a 20 cm x 20 cm Large Area Picosecond Photo Detector (LAPPD) manufactured by INCOM Inc. at multiple locations within the same device under different operating conditions. We compare the aging behavior of the MCP-PMT obtained from the first lifetime test conducted under high gain conditions to the lifetime obtained at a different gain. Through this work, we aim to correlate the lifetime of the MCP-PMT and the rate of ion feedback, which is a function of the gain of each MCP, and which can also vary from point to point across a large area (400 $cm^2$) MCP. The tests were made possible by the uniqueness of the LAPPD design, which allows independent control of the gain of the chevron stacked MCPs. We will further discuss the implications of our results for optimizing the operating conditions of the detector when used in high event rate experiments.Keywords: electron multipliers (vacuum), LAPPD, lifetime, micro-channel plate photo-multipliers tubes, photoemission, time-of-flight
Procedia PDF Downloads 178215 Infrared Thermography Applications for Building Investigation
Authors: Hamid Yazdani, Raheleh Akbar
Abstract:
Infrared thermography is a modern non-destructive measuring method for the examination of redeveloped and non-renovated buildings. Infrared cameras provide a means for temperature measurement in building constructions from the inside, as well as from the outside. Thus, heat bridges can be detected. It has been shown that infrared thermography is applicable for insulation inspection, identifying air leakage and heat losses sources, finding the exact position of heating tubes or for discovering the reasons why mold, moisture is growing in a particular area, and it is also used in conservation field to detect hidden characteristics, degradations of building structures. The paper gives a brief description of the theoretical background of infrared thermography.Keywords: infrared thermography, examination of buildings, emissivity, heat losses sources
Procedia PDF Downloads 520214 Solar Heating System to Promote the Disinfection
Authors: Elmo Thiago Lins Cöuras Ford, Valentina Alessandra Carvalho do Vale
Abstract:
It presents a heating system using low cost alternative solar collectors to promote the disinfection of water in low income communities that take water contaminated by bacteria. The system consists of two solar collectors, with total area of 4 m² and was built using PET bottles and cans of beer and soft drinks. Each collector is made up of 8 PVC tubes, connected in series and work in continuous flow. It will determine the flux the most appropriate to generate the temperature to promote the disinfection. Will be presented results of the efficiency and thermal loss of system and results of analysis of water after undergoing the process of heating.Keywords: disinfection of water, solar heating system, poor communities, PVC
Procedia PDF Downloads 479213 The Prevalence of Intubation Induced Dental Complications among Hospitalized Patients
Authors: Dorsa Rahi, Arghavan Tonkanbonbi, Soheila Manifar, Behzad Jafvarnejad
Abstract:
Background and Aim: Intraoral manipulation is performed during endotracheal intubation for general anesthesia, which can traumatize the soft and hard tissue in the oral cavity and cause postoperative pain and discomfort. Dental trauma is the most common complication of intubation. This study aimed to assess the prevalence of dental complications due to intubation in patients hospitalized in Imam Khomeini Hospital during 2018-2019. Materials and Methods: A total of 805 patients presenting to the Cancer Institute of Imam Khomeini Hospital for preoperative anesthesia consultation were randomly enrolled. A dentist interviewed the patients and performed a comprehensive clinical oral examination preoperatively. The patients underwent clinical oral examination by another dentist postoperatively. Results: No significant correlation was found between dental trauma (tooth fracture, tooth mobility, or soft tissue injury) after intubation with the age or gender of patients. According to the Wilcoxon test and McNemar-Bowker Test, the rate of mobility before the intubation was significantly different from that after the intubation (P=0.000). Maxillary central incisors, maxillary left canine and mandibular right and left central incisors had the highest rate of fracture. Conclusion: Mobile teeth before the intubation are at higher risk of avulsion and aspiration during the procedure. Patients with primary temporomandibular joint disorders are more susceptible to post-intubation trismus.Keywords: oral trauma, dental trauma, intubation, anesthesia
Procedia PDF Downloads 148212 Negative Pressures of Ca. -20 MPA for Water Enclosed into a Metal Berthelot Tube under a Vacuum Condition
Authors: K. Hiro, Y. Imai, M. Tanji, H. Deguchi, K. Hatari
Abstract:
Negative pressures of liquids have been expected to contribute many kinds of technology. Nevertheless, experiments for subjecting liquids which have not too small volumes to negative pressures are difficult even now. The reason of the difficulties is because the liquids tend to generate cavities easily. In order to remove cavitation nuclei, an apparatus for enclosing water into a metal Berthelot tube under vacuum conditions was developed. By using the apparatus, negative pressures for water rose to ca. -20 MPa. This is the highest value for water in metal Berthelot tubes. Results were explained by a traditional crevice model. KeywordsKeywords: Berthelot method, negative pressure, cavitation nuclei, water
Procedia PDF Downloads 333211 A Review of Geotextile Tube with the Evaluation of Dewatering of High Water Content Sludge
Authors: Rajul Dwivedi, Mahesh Patel
Abstract:
Due to the scarcity of natural resources, common rivers and coastal structures are too expensive to build and maintain. One such method is to use geotextile tube technology to build marine protected structures, such as dams, canals, jetties, free breakwaters, etc. Geotextile tube technology has evolved from other construction technologies and improved into a more efficient solution. The coastal erosion problems have been exacerbated by the development of infrastructure associated with the expansion of urban and industrial activities. Resources and harbours and the removal of sea sand for use in this erosion event will accelerate the erosion of the sea. but in the coastal areas, due to depletion of sand or beach sandKeywords: geotextile tubes, slurry, dewatering, response surface
Procedia PDF Downloads 139210 Solar Heating System to Promote the Disinfection of Water
Authors: Elmo Thiago Lins Cöuras Ford, Valentina Alessandra Carvalho do Vale
Abstract:
It presents a heating system using low cost alternative solar collectors to promote the disinfection of water in low income communities that take water contaminated by bacteria. The system consists of two solar collectors, with total area of 4 m² and was built using PET bottles and cans of beer and soft drinks. Each collector is made up of 8 PVC tubes, connected in series and work in continuous flow. It will determine the flux the most appropriate to generate the temperature to promote the disinfection. It will be presented results of the efficiency and thermal loss of system and results of analysis of water after undergoing the process of heating.Keywords: Disinfection of water, solar heating system, poor communities, bioinformatics, biomedicine
Procedia PDF Downloads 486209 Different Processing Methods to Obtain a Carbon Composite Element for Cycling
Authors: Maria Fonseca, Ana Branco, Joao Graca, Rui Mendes, Pedro Mimoso
Abstract:
The present work is focused on the production of a carbon composite element for cycling through different techniques, namely, blow-molding and high-pressure resin transfer injection (HP-RTM). The main objective of this work is to compare both processes to produce carbon composite elements for the cycling industry. It is well known that the carbon composite components for cycling are produced mainly through blow-molding; however, this technique depends strongly on manual labour, resulting in a time-consuming production process. Comparatively, HP-RTM offers a more automated process which should lead to higher production rates. Nevertheless, a comparison of the elements produced through both techniques must be done, in order to assess if the final products comply with the required standards of the industry. The main difference between said techniques lies in the used material. Blow-moulding uses carbon prepreg (carbon fibres pre-impregnated with a resin system), and the material is laid up by hand, piece by piece, on a mould or on a hard male. After that, the material is cured at a high temperature. On the other hand, in the HP-RTM technique, dry carbon fibres are placed on a mould, and then resin is injected at high pressure. After some research regarding the best material systems (prepregs and braids) and suppliers, an element was designed (similar to a handlebar) to be constructed. The next step was to perform FEM simulations in order to determine what the best layup of the composite material was. The simulations were done for the prepreg material, and the obtained layup was transposed to the braids. The selected material was a prepreg with T700 carbon fibre (24K) and an epoxy resin system, for the blow-molding technique. For HP-RTM, carbon fibre elastic UD tubes and ± 45º braids were used, with both 3K and 6K filaments per tow, and the resin system was an epoxy as well. After the simulations for the prepreg material, the optimized layup was: [45°, -45°,45°, -45°,0°,0°]. For HP-RTM, the transposed layup was [ ± 45° (6k); 0° (6k); partial ± 45° (6k); partial ± 45° (6k); ± 45° (3k); ± 45° (3k)]. The mechanical tests showed that both elements can withstand the maximum load (in this case, 1000 N); however, the one produced through blow-molding can support higher loads (≈1300N against 1100N from HP-RTM). In what concerns to the fibre volume fraction (FVF), the HP-RTM element has a slightly higher value ( > 61% compared to 59% of the blow-molding technique). The optical microscopy has shown that both elements have a low void content. In conclusion, the elements produced using HP-RTM can compare to the ones produced through blow-molding, both in mechanical testing and in the visual aspect. Nevertheless, there is still space for improvement in the HP-RTM elements since the layup of the braids, and UD tubes could be optimized.Keywords: HP-RTM, carbon composites, cycling, FEM
Procedia PDF Downloads 132208 Comparison between Experimental and Numerical Studies of Fully Encased Composite Columns
Authors: Md. Soebur Rahman, Mahbuba Begum, Raquib Ahsan
Abstract:
Composite column is a structural member that uses a combination of structural steel shapes, pipes or tubes with or without reinforcing steel bars and reinforced concrete to provide adequate load carrying capacity to sustain either axial compressive loads alone or a combination of axial loads and bending moments. Composite construction takes the advantages of the speed of construction, light weight and strength of steel, and the higher mass, stiffness, damping properties and economy of reinforced concrete. The most usual types of composite columns are the concrete filled steel tubes and the partially or fully encased steel profiles. Fully encased composite column (FEC) provides compressive strength, stability, stiffness, improved fire proofing and better corrosion protection. This paper reports experimental and numerical investigations of the behaviour of concrete encased steel composite columns subjected to short-term axial load. In this study, eleven short FEC columns with square shaped cross section were constructed and tested to examine the load-deflection behavior. The main variables in the test were considered as concrete compressive strength, cross sectional size and percentage of structural steel. A nonlinear 3-D finite element (FE) model has been developed to analyse the inelastic behaviour of steel, concrete, and longitudinal reinforcement as well as the effect of concrete confinement of the FEC columns. FE models have been validated against the current experimental study conduct in the laboratory and published experimental results under concentric load. It has been observed that FE model is able to predict the experimental behaviour of FEC columns under concentric gravity loads with good accuracy. Good agreement has been achieved between the complete experimental and the numerical load-deflection behaviour in this study. The capacities of each constituent of FEC columns such as structural steel, concrete and rebar's were also determined from the numerical study. Concrete is observed to provide around 57% of the total axial capacity of the column whereas the steel I-sections contributes to the rest of the capacity as well as ductility of the overall system. The nonlinear FE model developed in this study is also used to explore the effect of concrete strength and percentage of structural steel on the behaviour of FEC columns under concentric loads. The axial capacity of FEC columns has been found to increase significantly by increasing the strength of concrete.Keywords: composite, columns, experimental, finite element, fully encased, strength
Procedia PDF Downloads 290207 Role of Hyperbaric Oxygen Therapy in Management of Diabetic Foot
Authors: Magdy Al Shourbagi
Abstract:
Diabetes mellitus is the commonest cause of neuropathy. The common pattern is a distal symmetrical sensory polyneuropathy, associated with autonomic disturbances. Less often, Diabetes mellitus is responsible for a focal or multifocal neuropathy. Common causes for non-healing of diabetic foot are the infection and ischemia. Diabetes mellitus is associated with a defective cellular and humoral immunity. Particularly, decreased phagocytosis, decreased chemotaxis, impaired bacterial killing and abnormal lymphocytic function resulting in a reduced inflammatory reaction and defective wound healing. Hyperbaric oxygen therapy is defined by the Undersea and Hyperbaric Medical Society as a treatment in which a patient intermittently breathes 100% oxygen and the treatment chamber is pressurized to a pressure greater than sea level (1 atmosphere absolute). The pressure increase may be applied in mono-place (single person) or multi-place chambers. Multi-place chambers are pressurized with air, with oxygen given via face mask or endotracheal tube; while mono-place chambers are pressurized with oxygen. Oxygen gas plays an important role in the physiology of wound healing. Hyperbaric oxygen therapy can raise tissue oxygen tensions to levels where wound healing can be expected. HBOT increases the killing ability of leucocytes also it is lethal for certain anaerobic bacteria and inhibits toxin formation in many other anaerobes. Multiple anecdotal reports and studies in HBO therapy in diabetic patients report that HBO can be an effective adjunct therapy in the management of diabetic foot wounds and is associated with better functional outcomes.Keywords: hyperbari oxygen therapy, diabetic foot, neuropathy, multiplace chambers
Procedia PDF Downloads 290206 Numerical and Analytical Approach for Film Condensation on Different Forms of Surfaces
Authors: A. Kazemi Jouybari, A. Mirabdolah Lavasani
Abstract:
This paper seeks to the solution of condensation around of a flat plate, circular and elliptical tube in way of numerical and analytical methods. Also, it calculates the entropy production rates. The first, problem was solved by using mesh dynamic and rational assumptions, next it was compared with the numerical solution that the result had acceptable errors. An additional supporting relation was applied based on a characteristic of condensation phenomenon for condensing elements. As it has been shown here, due to higher rates of heat transfer for elliptical tubes, they have more entropy production rates, in comparison to circular ones. Findings showed that two methods were efficient. Furthermore, analytical methods can be used to optimize the problem and reduce the entropy production rate.Keywords: condensation, numerical solution, analytical solution, entropy rate
Procedia PDF Downloads 216205 Eccentric Loading of CFDST Columns
Authors: Trevor N. Haas, Alexander Koen
Abstract:
Columns have traditionally been constructed of reinforced concrete or structural steel. Much attention was allocated to estimate the axial capacity of the traditional column sections to the detriment of other forms of construction. Other forms of column construction such as Concrete Filled Double Skin Tubes received little research attention, and almost no attention when subjected to eccentric loading. This paper investigates the axial capacity of columns when subjected to eccentric loading. The experimental axial capacities are compared to other established theoretical formulae on concentric loading to determine a possible relationship. The study found a good correlation between the reduction in axial capacity for different column lengths and hollow section ratios.Keywords: CSDST, CFST, axial capacity, hollow section ratios
Procedia PDF Downloads 341204 Life Prediction of Condenser Tubes Applying Fuzzy Logic and Neural Network Algorithms
Authors: A. Majidian
Abstract:
The life prediction of thermal power plant components is necessary to prevent the unexpected outages, optimize maintenance tasks in periodic overhauls and plan inspection tasks with their schedules. One of the main critical components in a power plant is condenser because its failure can affect many other components which are positioned in downstream of condenser. This paper deals with factors affecting life of condenser. Failure rates dependency vs. these factors has been investigated using Artificial Neural Network (ANN) and fuzzy logic algorithms. These algorithms have shown their capabilities as dynamic tools to evaluate life prediction of power plant equipments.Keywords: life prediction, condenser tube, neural network, fuzzy logic
Procedia PDF Downloads 351203 Cavitating Flow through a Venturi Using Computational Fluid Dynamics
Authors: Imane Benghalia, Mohammed Zamoum, Rachid Boucetta
Abstract:
Hydrodynamic cavitation is a complex physical phenomenon that appears in hydraulic systems (pumps, turbines, valves, Venturi tubes, etc.) when the fluid pressure decreases below the saturated vapor pressure. The works carried out in this study aimed to get a better understanding of the cavitating flow phenomena. For this, we have numerically studied a cavitating bubbly flow through a Venturi nozzle. The cavitation model is selected and solved using a commercial computational fluid dynamics (CFD) code. The obtained results show the effect of the inlet pressure (10, 7, 5, and 2 bars) of the Venturi on pressure, the velocity of the fluid flow, and the vapor fraction. We found that the inlet pressure of the Venturi strongly affects the evolution of the pressure, velocity, and vapor fraction formation in the cavitating flow.Keywords: cavitating flow, CFD, phase change, venturi
Procedia PDF Downloads 84202 Thermal Performance of Hybrid PVT Collector with Natural Circulation
Authors: K. Touafek, A. Khelifa, I. Tabet, H. Haloui, H. Bencheikh El Houcine, M. Adouane
Abstract:
Hybrid photovoltaic thermal (PVT) collectors allow simultaneous production of electrical energy thus heat energy. There are several configurations of hybrid collectors (to produce water or air). For hybrids water collectors, there are several configurations that differ by the nature of the absorber (serpentine, tubes...). In this paper, an absorber tank is studied. The circulation of the coolant is natural (we do not use the pump). We present the obtained results in our experimental study and we analyzed the data, and then we compare the results with the theory practices. The electrical performances of the hybrid collector are compared with those of conventional photovoltaic module mounted on the same structure and measured under the same conditions. We conducted experiments with natural circulation of the coolant (Thermosyphon), for a flow rate of 0.025kg/m².Keywords: experimental, photovoltaic, solar, temperature, tank
Procedia PDF Downloads 320201 SEM-EBSD Observation for Microtubes by Using Dieless Drawing Process
Authors: Takashi Sakai, Itaru Kumisawa
Abstract:
Because die drawing requires insertion of a die, a plug, or a mandrel, higher precision and efficiency are demanded for drawing equipment for a tube having smaller diameter. Manufacturing of such tubes is also accompanied by problems such as cracking and fracture. We specifically examine dieless drawing, which is less affected by these drawing-related difficulties. This deformation process is governed by a similar principle to that of reduction in diameter when pulling a heated glass tube. We conducted dieless drawing of SUS304 stainless steel microtubes under various conditions with three factor parameters of heating temperature, area reduction, and drawing speed. We used SEM-EBSD to observe the processing condition effects on microstructural elements. As the result of this study, crystallographic orientation of microtube is clear by using SEM-EBSD analysis.Keywords: microtube, dieless drawing, IPF (inverse pole figure), GOS (grain orientation spread), crystallographic analysis
Procedia PDF Downloads 248200 Robust Control of Cyber-Physical System under Cyber Attacks Based on Invariant Tubes
Authors: Bruno Vilić Belina, Jadranko Matuško
Abstract:
The rapid development of cyber-physical systems significantly influences modern control systems introducing a whole new range of applications of control systems but also putting them under new challenges to ensure their resiliency to possible cyber attacks, either in the form of data integrity attacks or deception attacks. This paper presents a model predictive approach to the control of cyber-physical systems robust to cyber attacks. We assume that a cyber attack can be modelled as an additive disturbance that acts in the measuring channel. For such a system, we designed a tube-based predictive controller based. The performance of the designed controller has been verified in Matlab/Simulink environment.Keywords: control systems, cyber attacks, resiliency, robustness, tube based model predictive control
Procedia PDF Downloads 67199 Development of Clinical Nursing Practice Guideline to Prevent Infection During Intubation in Suspected or Confirmed Covid-19 Patients
Authors: Sarinra Thongmee, Adithep Mingsuan, Chanyapak Polkhet, Supattra Wongsuk, Krittaphon Prakobsaeng
Abstract:
The purposes of this research and development was to develop and evaluation of clinical nursing practice guideline (CNPG) for the prevention of infection during intubation in patient withsuspected or confirmedCOVID-19 patient. This study was developed by using the evidence based practice model of Soukup (2000) as a conceptual framework. The study consisted of 4 steps: 1) situational analysis of intubation service in patients with confirmed COVID-19, 2) development the CNPG, 3) apply the NPG to trial, and 4) evaluation of the NPG. Thesample consisted of 52 nurse anesthetists and 25 infected or suspected COVID-19 patients. The research instrument consisted of 1) CNPG, 2) the nurses anesthetist opinion questionnaire to the guideline, 3) the evaluation practice form, and 4) the nurse anesthetist knowledge test on nursing care of patients infected with COVID-19. Data were analyzed by using descriptive statistics, and Wilcoxon matched-pairs signed rank test. The results found that this developed NPG consists of 4 sections: 1) NPG for Preventing Airborne Infection Prevention2) preparation of anesthetic and intubation equipments 3) roles and duties of the intubation team 4) guidelines for intubation in suspected or confirmed COVID-19patients. The result found that 1) provider: using NPG in providers revealed that nurse anesthetist had higher mean of knowledge scores than before using NPG statistically significant at the 0.05 level (p<0.01) and able to follow the NPG 100% in all activities. The anesthetic team was not infected with COVID-19from intubation outside operating room.2) Client: the patient was safe, no complications from intubation. Summary CNPG to prevent infection in intubation of suspected or confirmedCOVID-19 patient was appropriate and applicable to practice.Keywords: nursing practice guideline, prevention of infection, endotracheal intubation, COVID-19
Procedia PDF Downloads 142198 Comparison of Mcgrath, Pentax, and Macintosh Laryngoscope in Normal and Cervical Immobilized Manikin by Novices
Authors: Jong Yeop Kim, In Kyong Yi, Hyun Jeong Kwak, Sook Young Lee, Sung Yong Park
Abstract:
Background: Several video laryngoscopes (VLs) were used to facilitate tracheal intubation in the normal and potentially difficult airway, especially by novice personnel. The aim of this study was to compare tracheal intubation performance regarding the time to intubation, glottic view, difficulty, and dental click, by a novice using McGrath VL, Pentax Airway Scope (AWS) and Macintosh laryngoscope in normal and cervical immobilized manikin models. Methods: Thirty-five anesthesia nurses without previous intubation experience were recruited. The participants performed endotracheal intubation in a manikin model at two simulated neck positions (normal and fixed neck via cervical immobilization), using three different devices (McGrath VL, Pentax AWS, and Macintosh direct laryngoscope) at three times each. Performance parameters included intubation time, success rate of intubation, Cormack Lehane laryngoscope grading, dental click, and subjective difficulty score. Results: Intubation time and success rate at the first attempt were not significantly different between the 3 groups in normal airway manikin. In the cervical immobilized manikin, the intubation time was shorter (p = 0.012) and the success rate with the first attempt was significantly higher (p < 0.001) when using McGrath VL and Pentax AWS compared with Macintosh laryngoscope. Both VLs showed less difficulty score (p < 0.001) and more Cormack Lehane grade I (p < 0.001). The incidence of dental clicks was higher with McGrath VL than Macintosh laryngoscope in the normal and cervical immobilized airway (p = 0.005, p < 0.001, respectively). Conclusion: McGrath VL and Pentax AWS resulted in shorter intubation time, higher first attempt success rate, compared with Macintosh laryngoscope by a novice intubator in a cervical immobilized manikin model. McGrath VL could be reduced the risk of dental injury compared with Macintosh laryngoscope in this scenario.Keywords: intubation, manikin, novice, videolaryngoscope
Procedia PDF Downloads 158197 The Effect of Increase in Aluminium Content on Fluidity of ZA Alloys Processed by Centrifugal Casting
Authors: P. N. Jyothi, A. Shailesh Rao, M. C. Jagath, K. Channakeshavalu
Abstract:
Uses of ZA alloys as bearing material have been increased due to their superior mechanical properties, wear characteristics and tribological properties. Among ZA alloys, ZA 27 alloy has higher strength, low density with excellent bearing and wear characteristics. From the past research work, it is observed that in continuous casting as Al content increases, the fluidity also increases. In present work, ZA 8, ZA 12 and ZA 27 alloys have been processed through centrifugal casting process at 600 rotational speed of the mould. Uniform full cylinder is casted with ZA 8 alloy. For ZA 12 and ZA 27 alloys where the Al content is higher, cast tubes were not complete and uniform. The reason is Al may be acting as a refiner and reduce the melt flow in the rotating mould. This is mainly due to macro-segregation of Al, which has occurred due to difference in densities of Al and Zn.Keywords: centrifugal casting, metal flow, characterization, systems engineering
Procedia PDF Downloads 328196 Evaluating of Design Codes for Circular High Strength Concrete-Filled Steel Tube Columns
Authors: Soner Guler, Eylem Guzel, Mustafa Gülen
Abstract:
Recently, concrete-filled steel tube columns are highly popular in high-rise buildings. The main aim of this study is to evaluate the axial load capacities of circular high strength concrete-filled steel tube columns according to Eurocode 4 (EC4) and American Concrete Institute (ACI) design codes. The axial load capacities of fifteen concrete-filled steel tubes stub columns were compared with design codes EU4 and ACI. The results showed that the EC4 overestimate the axial load capacity for all the specimens.Keywords: concrete-filled steel tube column, axial load capacity, Eurocode 4, ACI design codes
Procedia PDF Downloads 388195 Simulation and Optimization of an Annular Methanol Reformer
Authors: Shu-Bo Yang, Wei Wu, Yuan-Heng Liu
Abstract:
This research aims to design a heat-exchanger type of methanol reformer coupled with a preheating design in gPROMS® environment. The endothermic methanol steam reforming reaction (MSR) and the exothermic preferential oxidation reaction (PROX) occur in the inner tube and the outer tube of the reformer, respectively. The effective heat transfer manner between the inner and outer tubes is investigated. It is verified that the countercurrent-flow type reformer provides the higher hydrogen yield than the cocurrent-flow type. Since the hot spot temperature appears in the outer tube, an improved scheme is proposed to suppress the hot spot temperature by splitting the excess air flowing into two sites. Finally, an optimization algorithm for maximizing the hydrogen yield is employed to determine optimal operating conditions.Keywords: methanol reformer, methanol steam reforming, optimization, simulation
Procedia PDF Downloads 332194 The Development of Clinical Nursing Practice Guidelines for Preventing of Infection during Intubation in Patients with Suspected or Confirmed COVID-19
Authors: Sarinra Thongmee, Krittaporn Prakobsaeng, Adithep Mingsuan, Chanyapak Polkhet, Supattra Wongsuk
Abstract:
The purposes of this research and developmentwasto develop and evaluation of the clinical nursingpractice guideline (CNPG) for the prevention infection during intubation in patient with suspected or confirmedCOVID-19 patient. This study was developed by using the evidencebased practice model of Soukup (2000) asa conceptual framework. The study consisted of 4 steps: 1) situational analysis of intubation service in patientswith confirmed COVID-19; 2) development of the CNPG; 3) apply the NPG to trial; and 4) evaluation of the CNPG. The sample consisted of 52 nurse anesthetists and 25 infected or suspected COVID-19 patients. The research instrument consisted of 1) the CNPG, which was developed by the researchers; 2) the nurses anesthetist opinion questionnaire to the guideline; 3) the evaluation practice form; and 4) the nurse anesthetist knowledge test on nursing care of patients infected with COVID-19. Data were analyzed by using descriptive statistics, and Wilcoxon matched-pairs signed rank test. The results revealed this developed CNPG consists of 4 sections: 1)the CNPG for airborne precautions2) the preparation of anesthetic and intubation equipments3) the roles and duties of the intubation team, 4) the guidelines for intubation in suspected or confirmed COVID-19 patients. The results of CNPG use found that 1)the provider: using NPG in providers revealed that nurse anesthetist had a higher mean of knowledge scores than before using CNPG statistically significant at the 0.05 level (p<0.01) and able to follow the NPG 100% inall activities. The anesthetic team was not infected with COVID-19 from intubation outside the operating room. 2)the client: the patient was safe, with no complications from intubation. Summary CNPG to prevent infection during reintubation of suspected or confirmedCOVID-19patient was appropriate and applicable to practice.Keywords: clinical nursing practice guideline, prevention of infection, endotracheal intubation, COVID-19
Procedia PDF Downloads 153193 The Implementation of a Numerical Technique to Thermal Design of Fluidized Bed Cooler
Authors: Damiaa Saad Khudor
Abstract:
The paper describes an investigation for the thermal design of a fluidized bed cooler and prediction of heat transfer rate among the media categories. It is devoted to the thermal design of such equipment and their application in the industrial fields. It outlines the strategy for the fluidization heat transfer mode and its implementation in industry. The thermal design for fluidized bed cooler is used to furnish a complete design for a fluidized bed cooler of Sodium Bicarbonate. The total thermal load distribution between the air-solid and water-solid along the cooler is calculated according to the thermal equilibrium. The step by step technique was used to accomplish the thermal design of the fluidized bed cooler. It predicts the load, air, solid and water temperature along the trough. The thermal design for fluidized bed cooler revealed to the installation of a heat exchanger consists of (65) horizontal tubes with (33.4) mm diameter and (4) m length inside the bed trough.Keywords: fluidization, powder technology, thermal design, heat exchangers
Procedia PDF Downloads 513192 Three Dimensional Computational Fluid Dynamics Simulation of Wall Condensation inside Inclined Tubes
Authors: Amirhosein Moonesi Shabestary, Eckhard Krepper, Dirk Lucas
Abstract:
The current PhD project comprises CFD-modeling and simulation of condensation and heat transfer inside horizontal pipes. Condensation plays an important role in emergency cooling systems of reactors. The emergency cooling system consists of inclined horizontal pipes which are immersed in a tank of subcooled water. In the case of an accident the water level in the core is decreasing, steam comes in the emergency pipes, and due to the subcooled water around the pipe, this steam will start to condense. These horizontal pipes act as a strong heat sink which is responsible for a quick depressurization of the reactor core when any accident happens. This project is defined in order to model all these processes which happening in the emergency cooling systems. The most focus of the project is on detection of different morphologies such as annular flow, stratified flow, slug flow and plug flow. This project is an ongoing project which has been started 1 year ago in Helmholtz Zentrum Dresden Rossendorf (HZDR), Fluid Dynamics department. In HZDR most in cooperation with ANSYS different models are developed for modeling multiphase flows. Inhomogeneous MUSIG model considers the bubble size distribution and is used for modeling small-scaled dispersed gas phase. AIAD (Algebraic Interfacial Area Density Model) is developed for detection of the local morphology and corresponding switch between them. The recent model is GENTOP combines both concepts. GENTOP is able to simulate co-existing large-scaled (continuous) and small-scaled (polydispersed) structures. All these models are validated for adiabatic cases without any phase change. Therefore, the start point of the current PhD project is using the available models and trying to integrate phase transition and wall condensing models into them. In order to simplify the idea of condensation inside horizontal tubes, 3 steps have been defined. The first step is the investigation of condensation inside a horizontal tube by considering only direct contact condensation (DCC) and neglect wall condensation. Therefore, the inlet of the pipe is considered to be annular flow. In this step, AIAD model is used in order to detect the interface. The second step is the extension of the model to consider wall condensation as well which is closer to the reality. In this step, the inlet is pure steam, and due to the wall condensation, a liquid film occurs near the wall which leads to annular flow. The last step will be modeling of different morphologies which are occurring inside the tube during the condensation via using GENTOP model. By using GENTOP, the dispersed phase is able to be considered and simulated. Finally, the results of the simulations will be validated by experimental data which will be available also in HZDR.Keywords: wall condensation, direct contact condensation, AIAD model, morphology detection
Procedia PDF Downloads 304