Search results for: patient specific implants
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 10334

Search results for: patient specific implants

10244 Fahr Dsease vs Fahr Syndrome in the Field of a Case Report

Authors: Angelis P. Barlampas

Abstract:

Objective: The confusion of terms is a common practice in many situations of the everyday life. But, in some circumstances, such as in medicine, the precise meaning of a word curries a critical role for the health of the patient. Fahr disease and Fahr syndrome are often falsely used interchangeably, but they are two different conditions with different physical histories of different etiology and different medical management. A case of the seldom Fahr disease is presented, and a comparison with the more common Fahr syndrome follows. Materials and method: A 72 years old patient came to the emergency department, complaining of some kind of non specific medal disturbances, like anxiety, difficulty of concentrating, and tremor. The problems had a long course, but he had the impression of getting worse lately, so he decided to check them. Past history and laboratory tests were unremarkable. Then, a computed tomography examination was ordered. Results: The CT exam showed bilateral, hyperattenuating areas of heavy, dense calcium type deposits in basal ganglia, striatum, pallidum, thalami, the dentate nucleus, and the cerebral white matter of frontal, parietal and iniac lobes, as well as small areas of the pons. Taking into account the absence of any known preexisting illness and the fact that the emergency laboratory tests were without findings, a hypothesis of the rare Fahr disease was supposed. The suspicion was confirmed with further, more specific tests, which showed the lack of any other conditions which could probably share the same radiological image. Differentiating between Fahr disease and Fahr syndrome. Fahr disease: Primarily autosomal dominant Symmetrical and bilateral intracranial calcifications The patient is healthy until the middle age Absence of biochemical abnormalities. Family history consistent with autosomal dominant Fahr syndrome :Earlier between 30 to 40 years old. Symmetrical and bilateral intracranial calcifications Endocrinopathies: Idiopathic hypoparathyroidism, secondary hypoparathyroidism, hyperparathyroidism, pseudohypoparathyroidism ,pseudopseudohypoparathyroidism, e.t.c The disease appears at any age There are abnormal laboratory or imaging findings. Conclusion: Fahr disease and Fahr syndrome are not the same illness, although this is not well known to the inexperienced doctors. As clinical radiologists, we have to inform our colleagues that a radiological image, along with the patient's history, probably implies a rare condition and not something more usual and prompt the investigation to the right route. In our case, a genetic test could be done earlier and reveal the problem, and thus avoiding unnecessary and specific tests which cost in time and are uncomfortable to the patient.

Keywords: fahr disease, fahr syndrome, CT, brain calcifications

Procedia PDF Downloads 46
10243 Improving the Patient Guidance Satisfaction and Integrity of Patients Hospitalized in Iodine-131 Isolation Rooms

Authors: Yu Sin Syu

Abstract:

Objective: The study aimed to improve the patient guidance satisfaction of patients hospitalized in iodine-131 isolation rooms, as well as the patient guidance completion rate for such patients. Method: A patient care guidance checklist and patient care guidance satisfaction questionnaire were administered to 29 patients who had previously been hospitalized in iodine-131 isolation rooms. The evaluation was conducted on a one-on-one basis, and its results showed that the patients’ satisfaction with patient guidance was only 3.7 points and that the completion rate for the patient guidance performed by nurses was only 67%. Therefore, various solutions were implemented to create a more complete patient guidance framework for nurses, including the incorporation of regular care-related training in in-service education courses; the establishment of patient care guidance standards for patients in iodine-131 isolation rooms; the establishment of inpatient care standards and auditing processes for iodine-131 isolation rooms; the creation of an introductory handbook on ward environment; Invite other the care team the revision of iodine-131 health education brochures; the creation of visual cards and videos covering equipment operation procedures; and introduction of QR codes. Results: Following the implementation of the above measures, the overall satisfaction of patients hospitalized in iodine-131 isolation rooms increased from 3.7 points to 4.6 points, and the completion rate for patient guidance rose from 67% to 100%. Conclusion: Given the excellent results achieved in this study, it is hoped that this nursing project can serve as a benchmark for other relevant departments.

Keywords: admission care guidance, guidance satisfaction, integrity, Iodine131 isolation

Procedia PDF Downloads 108
10242 Integrating Nursing Informatics to Improve Patient-Centered Care: A Project to Reduce Patient Waiting Time at the Blood Pressure Counter

Authors: Pi-Chi Wu, Tsui-Ping Chu, Hsiu-Hung Wang

Abstract:

Background: The ability to provide immediate medical service in outpatient departments is one of the keys to patient satisfaction. Objectives: This project used electronic equipment to integrate nursing care information to patient care at a blood pressure diagnostic counter. Through process reengineering, the average patient waiting time decreased from 35 minutes to 5 minutes, while service satisfaction increased from a score of 2.7 to 4.6. Methods: Data was collected from a local hospital in Southern Taiwan from a daily average of 2,200 patients in the outpatient department. Previous waiting times were affected by (1) space limitations, (2) the need to help guide patient mobility, (3) the need for nurses to appease irate patients and give instructions, (4), the need for patients to replace lost counter tickets, (5) the need to re-enter information, (6) the replacement of missing patient information. An ad hoc group was established to enhance patient satisfaction and shorten waiting times for patients to see a doctor. A four step strategy consisting of (1) counter relocation, (2) queue reorganization, (3) electronic information integration, (4) process reengineering was implemented. Results: Implementation of the developed strategy decreased patient waiting time from 35 minutes to an average of 5 minutes, and increased patient satisfaction scores from 2.7 to 6.4. Conclusion: Through the integration of information technology and process transformation, waiting times were drastically reduced, patient satisfaction increased, and nurses were allowed more time to engage in more cost-effective services. This strategy was simultaneously enacted in separate hospitals throughout Taiwan.

Keywords: process reengineering, electronic information integration, patient satisfaction, patient waiting time

Procedia PDF Downloads 363
10241 From Transference Love to Self Alienation in the Therapeutic Relationship: A Case Study

Authors: Efi Koutantou

Abstract:

The foundation of successful therapy is the bond between the psychotherapist and the patient, Psychoanalysis would argue. The present study explores lived experiences of a psychotherapeutic relationship in different moments, initial and final with special reference to the transference love developed through the process. The fight between moments of ‘leaving a self’ behind and following ‘lines of flight’ in the process of creating a new subjectivity and ‘becoming-other’ will be explored. Moments between de-territorialisation – surpassing given constraints such as gender, family and religion, kinship bonds - freeing the space in favor of re-territorialisation – creation of oneself creation of oneself will also be analyzed. The generation of new possibilities of being, new ways of self-actualization for this patient will be discussed. The second part of this study will explore the extent to which this ‘transference love’ results for this specific patient to become ‘the discourse of the other’; it is a desideratum whether the patient finally becomes a subject of his/her own through his/her own self-exploration of new possibilities of existence or becomes alienated within the thought of the therapist. The way in which the patient uses or is (ab)used by the transference love in order to experience and undergo alienation from an ‘authority’ which may or may not sacrifice his/her own thought in favor of satisfying the therapist will be investigated. Finally, from an observer’s perspective and from the analysis of the results of this therapeutic relationship, the counter-transference will also be analyzed, in terms of an attempt of the analyst to relive and satisfy his/her own desires through the life of the analysand. The accession and fall of an idealized self will be analyzed, the turn of the transference love into ‘hate’ will conclude this case study through a lived experience in the therapeutic procedure; a relationship which can be called to be a mixture of a real relationship and remnants from a past object relationship.

Keywords: alienation, authority, counter-transference, hate, transference love

Procedia PDF Downloads 194
10240 Impact of Flexibility on Patient Satisfaction and Behavioral Intention: A Critical Reassessment and Model Development

Authors: Pradeep Kumar, Shibashish Chakraborty, Sasadhar Bera

Abstract:

In the anticipation of demand fluctuations, services cannot be inventoried and hence it creates a difficult problem in marketing of services. The inability to meet customers (patients) requirements in healthcare context has more serious consequences than other service sectors. In order to meet patient requirements in the current uncertain environment, healthcare organizations are seeking ways for improved service delivery. Flexibility provides a mechanism for reducing variability in service encounters and improved performance. Flexibility is defined as the ability of the organization to cope with changing circumstances or instability caused by the environment. Patient satisfaction is an important performance outcome of healthcare organizations. However, the paucity of information exists in healthcare delivery context to examine the impact of flexibility on patient satisfaction and behavioral intention. The present study is an attempt to develop a conceptual foundation for investigating overall impact of flexibility on patient satisfaction and behavioral intention. Several dimensions of flexibility in healthcare context are examined and proposed to have a significant impact on patient satisfaction and intention. Furthermore, the study involves a critical examination of determinants of patient satisfaction and development of a comprehensive view the relationship between flexibility, patient satisfaction and behavioral intention. Finally, theoretical contributions and implications for healthcare professionals are suggested from flexibility perspective.

Keywords: healthcare, flexibility, patient satisfaction, behavioral intention

Procedia PDF Downloads 347
10239 Biological Evaluation of Some Modern Titanium Alloys for Dental Implants

Authors: Roxana Maria Angelescu, Raluca Ion, Anişoara Cîmpean, Doina Răducanu, Mariana Lucia Angelescu

Abstract:

In an attempt to find titanium alloys that fulfill the requirements for mechanical and biological compatibility, laboratory and material related tests were performed during the years, as well as preclinical and clinical trials. The multidisciplinary scientific research facilitates the global evaluation of biocompatibility and osseointegration regarding the dental implant alloys. The aim of this study was to determine the in vitro biocompatibility of three modern titanium alloys: Ti-31.7Nb-6.21Zr-1.4Fe-0.16O (wt%), Ti-36.5Nb-4.5Zr-3Ta-0.16O (wt%) and Ti-20Nb-5Ta (wt%), in order to establish whether the use of these titanium alloys can have any toxic or injurious effects on biological systems. The commonly used Ti-6Al-4V alloy was investigated as a reference material. The behavior of MC3T3-E1 pre-osteoblasts on all these four metallic surfaces was evaluated. The tests of immunofluorescence, cytotoxicity and cellular proliferation lead to the conclusion that the newly-developed titanium alloys elicit a good cellular response in terms of cellular survival, adhesion, morphology and proliferative potential as well.

Keywords: biocompatibility tests, dental implants, titanium alloys, biomedical engineering

Procedia PDF Downloads 484
10238 Catamenial Pneumothorax: Report of Two Cases and Review of the Local Literature

Authors: Angeli Marie P. Lagman, Nephtali M. Gorgonio

Abstract:

Catamenial pneumothorax is defined as a recurrent accumulation of air in the pleural cavity, which occurs in the period of 72 hours before or after menses. In a menstruating woman presenting with the difficulty of breathing and chest pain with concomitant radiographic evidence of pneumothorax, a diagnosis of catamenial pneumothorax should be entertained. Two cases of catamenial pneumothorax were reported in our local literature. This report added two more cases. The first case is 45 years old G1P1, while the second case is 46 years old G2P2. These two patients had a history of pelvic endometriosis in the past. All other signs and symptoms were similar to the previously reported cases. All patients presented with difficulty of breathing associated with chest pain. Imaging studies showed right-sided pneumothorax in all patients. Intraoperatively, subpleural bleb, diaphragmatic fenestrations, and endometriotic implants were found. Three patients underwent video-assisted thoracosurgery (VATS), while one patient underwent open thoracotomy with pleurodesis. Histopathology revealed endometriosis in only two patients. All patients received postoperative hormonal therapy, and there were no recurrences noted in all patients. Endometriosis-related catamenial pneumothorax is a rare condition that needs early recognition of the symptoms. Several theories may be involved to explain the pathogenesis of catamenial pneumothorax. Two cases show a strong significant association between a history of pelvic endometriosis and the development of catamenial pneumothorax, while one case can be explained by the hormonal theory. The difficulty of breathing and chest pain in relation to menses may prompt early diagnosis. One case has shown that pneumothorax may occur even after menstruation. A biopsy of the endometrial implants may not always show endometrial glands and stroma, nor will immunostaining, which will not always show estrogen and progesterone receptors. Video-assisted thoracoscopic surgery is the gold standard in the diagnosis and treatment of catamenial pneumothorax. Postoperative hormonal suppression will further reduce the disease recurrence and facilitate the effectiveness of the surgical treatment.

Keywords: catamenial pneumothorax, endometriosis, menstruation, video assisted thoracosurgery

Procedia PDF Downloads 84
10237 Development and Characterization of Controlled Release Photo Cross-Linked Implants for Ocular Delivery of Triamcinolone Acetonide

Authors: Ravi Sheshala, Annie Lee, Ai Lin Ong, Ling Ling Cheu, Thiagarajan Madheswaran, Thankur R. R. Singh

Abstract:

The objectives of the present research work were to develop and characterize biodegradable controlled release photo cross-linked implants of Triamcinolone Acetonide (TA) for the treatment of chronic ocular diseases. The photo cross-linked implants were prepared using film casting technique by mixing TA (2.5%) polyethylene glycol diacrylate (PEGDA 700), pore formers (mannitol, maltose, and gelatin) and the photoinitiator (Irgacure 2959). The resulting mixture was injected into moulds using 21 G and subjected to photocrosslinking at 365 nm. Scanning electron microscopy results demonstrated that more pores were formed in the films with the increase in the concentration of pore formers from 2%-10%. The maximum force required to break the films containing 2-10% of pore formers were determined in both dry and wet conditions using texture analyzer and found that films in a dry condition required a higher force to break compared to wet condition and blank films. In vitro drug release from photo cross-linked films were determined by incubating samples in 50 ml PBS pH 7.4 at 37 C and the samples were analyzed for drug release by HPLC. The films demonstrated a biphasic release profile i.e. an initial burst release (<20%) on the first day followed by a constant and continuous drug release in a controlled manner for 42 days. The drug release from all formulations followed the first-order release pattern and the combination of diffusion and erosion release mechanism. In conclusion, the developed formulations were able to provide controlled drug delivery to treat the chronic ocular diseases.

Keywords: controlled release, ophthalmic, PEGDA, photocrosslinking, pore formers

Procedia PDF Downloads 390
10236 Prosthetic Rehabilitation of Midfacial: Nasal Defects

Authors: Bilal Ahmed

Abstract:

Rehabilitation of congenital and acquired maxillofacial defects is always a challenging clinical scenario. These defects pose major physiological and psychological threat not only to the patient but to the entire family. There has been an enormous scientific development in maxillofacial rehabilitation with the advent of CAD CAM, 3-D scanning, Osseo-integrated implants and improved restorative materials. There are also specialized centers with latest diagnostic and treatment facilities in the developed countries. However, in certain clinical case scenarios, conventional prosthodontic principles are still the gold standards. Similarly in a less developed world, financial and technical constraints are factors affecting treatment planning and final outcomes. However, we can do a lot of benefits to the affected human beings, even with use of simple and cost-effective conventional prosthodontic techniques and materials. These treatment strategies may sometimes be considered as intermediate or temporary options, but with regular follow-up maintenance these can be used on a definitive basis.

Keywords: maxillofacial defects, obturators, prosthodontics, medical and health sciences

Procedia PDF Downloads 325
10235 An Exploratory Case Study of the Interference of Erotic Transference in the Longevity of Psychoanalytic Treatment

Authors: Mehravar Javid, Rohma Hassan, J. DeSilva

Abstract:

In this exploratory case study, a 37-year-old male patient who previously terminated treatment after four months of therapy with a different therapist begins anew with a 38-year-old female therapist and undergoes a similar cycle of premature termination, with added discourse caused by erotic transference. Process notes and records of the therapy treatment indicate that during the short course of treatment, the patient explored his difficulties navigating personal relationships, both current and past, and his difficulties coping with hypochondriasis. The therapist becomes tasked with not only navigating the patient’s inner conflict but also how she relates to the patient in the countertransference process while maintaining professional boundaries. This includes empathizing with the patient while also experiencing discomfort in the erotic transference from a professional standpoint. When the patient terminates once more, the therapist reflects on the possible reasons for termination. This includes the patient’s difficulties with tolerating interpretations, which cause him to blame himself for past events. These interpretations were also very frequent, contributing to the emotional burden the patient experienced. The therapist reflected on the use of interpretation versus exploration of the patient’s feelings and how exploring his feelings, including his feelings towards her, would have allowed for an opportunity to explore the emotions that troubled him more deeply. This includes exploring the patient’s anger and fear, which stem from unresolved conflicts from his childhood. Moreover, the erotic transference served as an enactment of previous experiences in which the patient feared losing what he loved, leading him to opt for premature termination instead of losing his ability to control the relationship and experience loss.

Keywords: countertransference, erotic transference, premature termination, therapist-client boundaries, transference

Procedia PDF Downloads 48
10234 Strategies for Patient Families Integration in Caregiving: A Consensus Opinion

Authors: Ibrahim A. Alkali

Abstract:

There is no reservation on the outstanding contribution of patient families in restoration of hospitalised patients, hence their consideration as essential component of hospital ward regimen. The psychological and emotional support a patient requires has been found to be solely provided by the patient’s family. However, consideration of their presence as one of the major functional requirements of an inpatient setting design have always been a source of disquiet, especially in developing countries where policies, norms and protocols of healthcare administration have no consideration for the patients’ family. This have been a major challenge to the hospital ward facilities, a concern for the hospital administration and patient management. The study therefore is aimed at obtaining a consensus opinion on the best approach for family integration in the design of an inpatient setting.  A one day visioning charrette involving Architects, Nurses, Medical Doctors, Healthcare assistants and representatives from the Patient families was conducted with the aim of arriving at a consensus opinion on practical design approach for sustainable family integration. Patient’s family are found to be decisive character of hospital ward regimen that cannot be undermined. However, several challenges that impede family integration were identified and subsequently a recommendation for an ideal approach. This will serve as a guide to both architects and hospital management in implementing much desired Patient and Family Centred Care.

Keywords: patient's family, inpatient setting, care giving, integration

Procedia PDF Downloads 191
10233 Patient Engagement in Healthcare and Health Literacy in China: A Survey in China

Authors: Qing Wu, Xuchun Ye, Qiuchen Wang, Kirsten Corazzini

Abstract:

Objective: It’s increasing acknowledged that patient engagement in healthcare and health literacy both have positive impact on patient outcome. Health literacy emphasizes the ability of individuals to understand and apply health information and manage health. Patients' health literacy affected their willingness to participate in decision-making, but its impact on the behavior and willingness of patient engagement in healthcare is not clear, especially in China. Therefore, this study aimed to explore the correlation between the behavior and willingness of patient engagement and health literacy. Methods: A cross-sectional survey was employed using the behavior and willingness of patient engagement in healthcare questionnaire, Chinese version All Aspects of Health Literacy Scale (AAHLS). A convenient sample of 443 patients was recruited from 8 general hospitals in Shanghai, Jiangsu Province and Zhejiang Province, from September 2016 to January 2017. Results: The mean score for the willingness was (4.41±0.45), and the mean score for the patient engagement behavior was (4.17±0.49); the mean score for the patient's health literacy was (2.36±0.29),the average score of its three dimensions- the functional literacy, the Communicative/interactive literacy and the Critical literacy, was (2.26±0.38), (2.28±0.42), and (2.61±0.43), respectively. Patients' health literacy was positively correlated with their willingness of engagement (r = 0.367, P < 0.01), and positively correlated with patient engagement behavior (r = 0.357, P < 0.01). All dimensions of health literacy were positively correlated with the behavior and willingness of patient engagement in healthcare; the dimension of Communicative/interactive literacy (r = 0.312, P < 0.01; r = 0.357, P < 0.01) and the Critical literacy (r = 0.357, P < 0.01; r = 0.357, P < 0.01) are more relevant to the behavior and willingness than the dimension of basic/functional literacy (r=0.150, P < 0.01; r = 0.150, P < 0.01). Conclusions: The behavior and willingness of patient engagement in healthcare are positively correlated with health literacy and its dimensions. In clinical work, medical staff should pay attention to patients’ health literacy, especially the situation that low literacy leads to low participation and provide health information to patients through health education or communication to improve their health literacy as well as guide them to actively and rationally participate in their own health care.

Keywords: patient engagement, health literacy, healthcare, correlation

Procedia PDF Downloads 148
10232 Readability of Trauma-Related Patient Education Materials from the AAOS and OTA Websites

Authors: Diane Ghanem, Oscar Covarrubias, Ridge Maxson, Samir Sabharwal, Babar Shafiq

Abstract:

Introduction: Web-based resources serve as a fundamental educational platform for orthopaedic trauma patients; however, they are notoriously written at a high grade reading level and are often too complicated for patients to benefit from them. The aim of this study is to perform an updated assessment of the readability of the AAOS trauma-related educational articles and compare their readability with that of injury-specific patient education materials developed by the OTA. Methods: All forty-six trauma-related articles on the AAOS patient education website were analyzed for readability. Two independent reviewers used the (1) Flesch-Kincaid Grade Level (FKGL) and the (2) Flesch Reading Ease (FRE) algorithms to calculate the readability level. Mean readability scores were compared across body part categories. One-sample t-test was done to compare mean FKGL with the recommended 6th-grade readability level and the average American adult reading level. Two-sample t-test was used to compare the readability scores of the AAOS trauma-related articles to those of the OTA. Results: The average FKGL and FRE for the AAOS articles were 8.9±0.74 and 57.2±5.8, respectively. All articles were written above the 6th-grade reading level. The average readability of the AAOS articles was significantly greater than the recommended 6th-grade and average American adult reading level. The average FKGL (8.9±0.74 vs 8.1±1.14) and FRE (57.2±5.8 vs 65.6±6.6) for all AAOS articles was significantly greater compared to that of OTA articles. Excellent agreement was observed between raters for the FKGL 0.956 (95%CI 0.922 - 0.975) and FRE 0.993 (95%CI 0.987 – 0.996). Discussion: Our findings suggest that, after almost a decade, the readability of the AAOS trauma-related articles remains unchanged. The AAOS and OTA trauma patient education materials have high readability levels and may be too difficult for patient comprehension. A need remains to improve the readability of these commonly used trauma education materials.

Keywords: american ocademy of orthopaedic surgeons, FKGL, FRE, orthopaedic trauma association, patient education, readability

Procedia PDF Downloads 50
10231 Antimicrobial Efficacy of 0.75% Metronidazole and 2% Chlorhexidine Gel Applied in Implant Screw Hole: A Clinical Trial

Authors: Mostafa Solati

Abstract:

Objectives: Considering the gap of information regarding the optimal antimicrobial efficacy of metronidazole for application in the implant screw hole, this study aimed to compare the antimicrobial efficacy of 0.75% metronidazole and 2% chlorhexidine (CHX) gel applied in the implant screw hole. Materials and Methods: This randomized controlled clinical trial evaluated 60 implants (20 patients, each requiring three implants) in three groups (n=20). In group 1, 0.75% metronidazole gel was applied to the implant screw hole. In group 2, 2% CHX gel was applied, and in group 3, no material was used. Microbial samples were collected from the screw holes after three months, and the microbial colonies were counted. Data were analyzed using ANOVA. Results: The number of bacteria in the control group was significantly higher than that in 0.75% metronidazole gel and 2% CHX groups (P<0.05). The CHX group caused the maximum reduction in colony count with no significant difference from the metronidazole group (P>0.05). Conclusion: The application of 0.75% metronidazole gel and 2% CHX can effectively decrease the colony count in the implant screw hole and can probably play a role in the preservation of peri-implant tissue health.

Keywords: dental implant, metronidazole, CHX, screw hole

Procedia PDF Downloads 55
10230 Using Augmented Reality to Enhance Doctor Patient Communication

Authors: Rutusha Bhutada, Gaurav Chavan, Sarvesh Kasat, Varsha Mujumdar

Abstract:

This software system will be an Augmented Reality application designed to maximize the doctor’s productivity by providing tools to assist in automating the patient recognition and updating patient’s records using face and voice recognition features, which would otherwise have to be performed manually. By maximizing the doctor’s work efficiency and production, the application will meet the doctor’s needs while remaining easy to understand and use. More specifically, this application is designed to allow a doctor to manage his productive time in handling the patient without losing eye-contact with him and communicate with a group of other doctors for consultation, for in-place treatments through video streaming, as a video study. The system also contains a relational database containing a list of doctor, patient and display techniques.

Keywords: augmented reality, hand-held devices, head-mounted devices, marker based systems, speech recognition, face detection

Procedia PDF Downloads 415
10229 Comparing ITV Definitions From 4D CT-PET and Breath-Hold Technique with Abdominal Compression

Authors: R. D. Esposito, P. Dorado Rodriguez, D. Planes Meseguer

Abstract:

In this work, we compare the contour of Internal Target Volume (ITV), for Stereotactic Body Radiation Therapy (SBRT) of a patient affected by a single liver metastasis, obtained from two different patient data acquisition techniques. The first technique consists in a free breathing Computer Tomography (CT) scan acquisition, followed by exhalation breath-hold and inhalation breath-hold CT scans, all of them applying abdominal compression while the second technique consists in a free breathing 4D CT-PET (Positron Emission Tomography) scan. Results obtained with these two methods are consistent, which demonstrate that at least for this specific case, both techniques are adequate for ITV contouring in SBRT treatments.

Keywords: 4D CT-PET, abdominal compression, ITV, SBRT

Procedia PDF Downloads 429
10228 Reverse Twin Block with Expansion Screw for Treatment of Skeletal Class III Malocclusion in Growing Patient: Case Report

Authors: Alfrina Marwan, Erna Sulistyawati

Abstract:

Class III malocclusion shows both skeletal and dentoalveolar component. Sketal Class III malocclusion can have variants in different region, maxilla or mandibular. Skeletal Class III malocclusion during growth period is considered to treat to prevent its severity in adulthood. Orthopedics treatment of skeletal Class III malocclusion in growing patient can be treated by using reverse twin block with expansion screw to modify the growth pattern. The objective of this case report was to describe the functional correction of skeletal Class III maloclussion using reverse twin block with expansion screw in growing patient. A patient with concave profile came with a chief complaint of aesthetic problems. The cephalometric analysis showed that patient had skeletal Class III malocclusion (ANB -50, SNA 75º, Wits appraisal -3 mm) with anterior cross bite and deep bite (overjet -3 mm, overbite 6 mm). In this case report, the patient was treated with reverse twin block appliance with expansion screw. After three months of treatment, the skeletal problems have been corrected (ANB -1°), overjet, overbite and aesthetic were improved. Reverse twin block appliance with expansion screw can be used as orthopedics treatment for skeletal Class III malocclusion in growing patient and can improve the aesthetic with great satisfaction which was the main complaint in this patient.

Keywords: maxilla retrognatism, reverse twin block, skeletal class III malocclusion, growing patient

Procedia PDF Downloads 181
10227 Influence of Coenzyme as a Corrosion Barrier for Biodegradable Magnesium

Authors: Minjung Park, Jimin Park, Youngwoon Kim, Hyungseop Han, Myoungryul Ok, Hojeong Jeon, Hyunkwang Seok, Yuchan Kim

Abstract:

Magnesium is an essential element in human body and has unique characteristics such as bioabsorbable and biodegradable properties. Therefore, there has been much attention on studies on the implants based on magnesium to avoid subsequent surgery. However, high amount of hydrogen gas is generated by relatively severe corrosion of magnesium especially in aqueous condition with chloride ions. And it contributes to the causes of swelling of skin and causes consequent inflammation of soft tissue where is directly in contact with implants. Therefore, there is still concern about the safety of the using biodegradable magnesium alloys, which is limited to various applications. In this study, we analyzed the influence of coenzyme on corrosion behavior of magnesium. The analysis of corrosion rate was held by using Hanks’ balanced salt solution (HBSS) as a body stimulated fluid and in condition of 37°C. Thus, with deferring the concentration of the coenzyme used in this study, corrosion rates from 0.0654ml/ cm² to 0.0438ml/cm² were observed in immersion tests. Also, comparable results were obtained in electrochemical tests. Results showed that hydrogen gas produced from corrosion of magnesium can be controlled.

Keywords: biodegradable magnesium, biomaterials, coenzyme, corrosion

Procedia PDF Downloads 397
10226 Contribution of Automated Early Warning Score Usage to Patient Safety

Authors: Phang Moon Leng

Abstract:

Automated Early Warning Scores is a newly developed clinical decision tool that is used to streamline and improve the process of obtaining a patient’s vital signs so a clinical decision can be made at an earlier stage to prevent the patient from further deterioration. This technology provides immediate update on the score and clinical decision to be taken based on the outcome. This paper aims to study the use of an automated early warning score system on whether the technology has assisted the hospital in early detection and escalation of clinical condition and improve patient outcome. The hospital adopted the Modified Early Warning Scores (MEWS) Scoring System and MEWS Clinical Response into Philips IntelliVue Guardian Automated Early Warning Score equipment and studied whether the process has been leaned, whether the use of technology improved the usage & experience of the nurses, and whether the technology has improved patient care and outcome. It was found the steps required to obtain vital signs has been significantly reduced and is used more frequently to obtain patient vital signs. The number of deaths, and length of stay has significantly decreased as clinical decisions can be made and escalated more quickly with the Automated EWS. The automated early warning score equipment has helped improve work efficiency by removing the need for documenting into patient’s EMR. The technology streamlines clinical decision-making and allows faster care and intervention to be carried out and improves overall patient outcome which translates to better care for patient.

Keywords: automated early warning score, clinical quality and safety, patient safety, medical technology

Procedia PDF Downloads 164
10225 Blood Flow Simulations to Understand the Role of the Distal Vascular Branches of Carotid Artery in the Stroke Prediction

Authors: Muhsin Kizhisseri, Jorg Schluter, Saleh Gharie

Abstract:

Atherosclerosis is the main reason of stroke, which is one of the deadliest diseases in the world. The carotid artery in the brain is the prominent location for atherosclerotic progression, which hinders the blood flow into the brain. The inclusion of computational fluid dynamics (CFD) into the diagnosis cycle to understand the hemodynamics of the patient-specific carotid artery can give insights into stroke prediction. Realistic outlet boundary conditions are an inevitable part of the numerical simulations, which is one of the major factors in determining the accuracy of the CFD results. The Windkessel model-based outlet boundary conditions can give more realistic characteristics of the distal vascular branches of the carotid artery, such as the resistance to the blood flow and compliance of the distal arterial walls. This study aims to find the most influential distal branches of the carotid artery by using the Windkessel model parameters in the outlet boundary conditions. The parametric study approach to Windkessel model parameters can include the geometrical features of the distal branches, such as radius and length. The incorporation of the variations of the geometrical features of the major distal branches such as the middle cerebral artery, anterior cerebral artery, and ophthalmic artery through the Windkessel model can aid in identifying the most influential distal branch in the carotid artery. The results from this study can help physicians and stroke neurologists to have a more detailed and accurate judgment of the patient's condition.

Keywords: stroke, carotid artery, computational fluid dynamics, patient-specific, Windkessel model, distal vascular branches

Procedia PDF Downloads 197
10224 Influence of Ligature Tightening on Bone Fracture Risk in Interspinous Process Surgery

Authors: Dae Kyung Choi, Won Man Park, Kyungsoo Kim, Yoon Hyuk Kim

Abstract:

The interspinous process devices have been recently used due to its advantages such as minimal invasiveness and less subsidence of the implant to the osteoporotic bone. In this paper, we have analyzed the influences of ligature tightening of several interspinous process devices using finite element analysis. Four types of interspinous process implants were inserted to the L3-4 spinal motion segment based on their surgical protocols. Inferior plane of L4 vertebra was fixed and 7.5 Nm of extension moment were applied on superior plane of L3 vertebra with 400N of compressive load along follower load direction and pretension of the ligature. The stability of the spinal unit was high enough than that of intact model. The higher value of pretension in the ligature led the decrease of dynamic stabilization effect in cases of the WallisTM, DiamTM, Viking, and Spear®. The results of present study could be used to evaluate surgical option and validate the biomechanical characteristics of the spinal implants.

Keywords: interspinous process device, bone fracture risk, lumbar spine, finite element analysis

Procedia PDF Downloads 390
10223 Prosthesis Design for Bilateral Hip Disarticulation Management

Authors: Mauricio Plaza, Willian Aperador

Abstract:

Hip disarticulation is an amputation through the hip joint capsule, removing the entire lower extremity, with a closure of the remaining musculature over the exposed acetabulum. Tumors of the distal and proximal femur were treated by total femur resection; a hip disarticulation sometimes is a performance for massive trauma with crush injuries to the lower extremity. This article discusses the design a system for rehabilitation of a patient with bilateral hip disarticulations. The prosthetics designed allowed the patient to do natural gait suspended between parallel articulate crutches with the body weight support between the crutches. The care of this patient was a challenge due to bilateral amputations at such a high level and the special needs of a patient mobility.

Keywords: amputation, prosthesis, mobility, hemipelvectomy

Procedia PDF Downloads 395
10222 Biomechanics of Ceramic on Ceramic vs. Ceramic on Xlpe Total Hip Arthroplasties During Gait

Authors: Athanasios Triantafyllou, Georgios Papagiannis, Vassilios Nikolaou, Panayiotis J. Papagelopoulos, George C. Babis

Abstract:

In vitro measurements are widely used in order to predict THAs wear rate implementing gait kinematic and kinetic parameters. Clinical tests of materials and designs are crucial to prove the accuracy and validate such measurements. The purpose of this study is to examine the affection of THA gait kinematics and kinetics on wear during gait, the essential functional activity of humans, by comparing in vivo gait data to in vitro results. Our study hypothesis is that both implants will present the same hip joint kinematics and kinetics during gait. 127 unilateral primary cementless total hip arthroplasties were included in the research. Independent t-tests were used to identify a statistically significant difference in kinetic and kinematic data extracted from 3D gait analysis. No statistically significant differences observed at mean peak abduction, flexion and extension moments between the two groups (P.abduction= 0,125, P.flexion= 0,218, P.extension= 0,082). The kinematic measurements show no statistically significant differences too (Prom flexion-extension= 0,687, Prom abduction-adduction= 0,679). THA kinematics and kinetics during gait are important biomechanical parameters directly associated with implants wear. In vitro studies report less wear in CoC than CoXLPE when tested with the same gait cycle kinematic protocol. Our findings confirm that both implants behave identically in terms of kinematics in the clinical environment, thus strengthening in vitro results of CoC advantage. Correlated to all other significant factors that affect THA wear could address in a complete prism the wear on CoC and CoXLPE.

Keywords: total hip arthroplasty biomechanics, THA gait analysis, ceramic on ceramic kinematics, ceramic on XLPE kinetics, total hip replacement wear

Procedia PDF Downloads 137
10221 Best Practices to Enhance Patient Security and Confidentiality When Using E-Health in South Africa

Authors: Lethola Tshikose, Munyaradzi Katurura

Abstract:

Information and Communication Technology (ICT) plays a critical role in improving daily healthcare processes. The South African healthcare organizations have adopted Information Systems to integrate their patient records. This has made it much easier for healthcare organizations because patient information can now be accessible at any time. The primary purpose of this research study was to investigate the best practices that can be applied to enhance patient security and confidentiality when using e-health systems in South Africa. Security and confidentiality are critical in healthcare organizations as they ensure safety in EHRs. The research study used an inductive research approach that included a thorough literature review; therefore, no data was collected. The research paper’s scope included patient data and possible security threats associated with healthcare systems. According to the study, South African healthcare organizations discovered various patient data security and confidentiality issues. The study also revealed that when it comes to handling patient data, health professionals sometimes make mistakes. Some may not be computer literate, which posed issues and caused data to be tempered with. The research paper recommends that healthcare organizations ensure that security measures are adequately supported and promoted by their IT department. This will ensure that adequate resources are distributed to keep patient data secure and confidential. Healthcare organizations must correctly use standards set up by IT specialists to solve patient data security and confidentiality issues. Healthcare organizations must make sure that their organizational structures are adaptable to improve security and confidentiality.

Keywords: E-health, EHR, security, confidentiality, healthcare

Procedia PDF Downloads 36
10220 The Experience of Applying Multi-Sensory Stimulation ICU for Arousing a Patient with Traumatic Brain Injury in Intensive Care

Authors: Hsiao-Wen Tsai

Abstract:

Motor vehicle accident is the first cause of head injury in the world; severe head injury cases may cause conscious disturbance and death. This is a report about a case of a young adult patient suffering from motor vehicle accident leading to severe head injury who passed through three time surgical procedures, and his mother (who is the informal caregiver). This case was followed from 28th January to 15th February 2011 by using Gordon’s 11 functional health patterns. Patient’s cognitive-perceptual and self-perception-self-concept patterns were altered. Anxiety was also noted on his informal caregiver due to patients’ condition. During the intensive care period, maintaining patient’s vital signs and cerebral perfusion pressure were essential to avoid secondary neuronal injury. Multi-sensory stimulation, caring accompanying, supporting, listening and encouraging patient’s family involved in patient care were very important to reduce informal caregiver anxiety. Finally, the patient consciousness improved from GCS 4 to GCS 11 before discharging from ICU. Patient’s primary informal caregiver, his mother, also showed anxiety improvement. This is was successful case with traumatic brain injury recovered from coma.

Keywords: anxiety, multi-sensory stimulation, reduce intracranial adaptive capacity, traumatic brain injury

Procedia PDF Downloads 248
10219 The Influences of Nurses’ Satisfaction on the Patient Satisfaction with and Loyalty to Korean University Hospitals

Authors: Sung Hee Ahn, Ju Rang Han

Abstract:

Background: With increasing importance in healthcare organization on patient satisfaction and nurses’ job satisfaction, many studies have been conducted. But no research has been administered how nurses’ satisfaction with healthcare organization influence patient satisfaction and loyalty. Purpose: This study aims to conceptualize nurses‘ satisfaction, patient satisfaction with and patient loyalty to hospitals using a hypothetical linear structural equation model, and to identify the significance of path coefficients and goodness of fit index of the structural equation model as well. Method: A total of 2,079 nurses and 6,776 patients recruited from 5 university hospitals in South Korea participated in this study. The data on nurses, including ward nurses and outpatient nurses, were collected from June 24th to July 12th, at the 204 departments of the 5 hospitals through an on-line survey. The data on the patients, including both inpatients and outpatients, were collected from September 30th to October 24th, 2013 at the 5 hospitals using a structured questionnaire. The variable of nurses’ satisfaction was measured using a scale evaluating internal client satisfaction, which is used in SSM Health Care System in the US. Patient satisfaction with the hospital and nurses and patient loyalty were measured by assessing the patient’s intention to revisit and to recommending the hospital to others using a visual analogue scale. The data were analyzed using SPSS version 21.0 and AMOS version 21.0. Result: The hypothetical model was fairly good in terms of goodness of fit (χ2= 64.897 (df=24, p <. 001), GFI=. 906, AGFI=.823, CFI=.921, NFI=.951, NNFI=.952. RMSEA=.114). The significance of path coefficients includes followings 1)The nurses’ satisfaction has significant influence on the patient satisfaction with nurses. 2)The patient satisfaction with nurses has significant influence on the patient satisfaction with the hospital. 3)The patient satisfaction with the hospital has significant influence on the patients’ revisit intention. 4)The patient satisfaction with the hospital has significant influence on the patients’ intention to the recommendations of the hospital. Conclusion: These results provide several practical implications to hospital administrators, who should incorporate ways of improving nurses' and patients' satisfaction with the hospital into their health care marketing strategies.

Keywords: linear structural equation model, loyalty, nurse, patient satisfaction

Procedia PDF Downloads 428
10218 Test and Evaluation of Patient Tracking Platform in an Earthquake Simulation

Authors: Nahid Tavakoli, Mohammad H. Yarmohammadian, Ali Samimi

Abstract:

In earthquake situation, medical response communities such as field and referral hospitals are challenged with injured victims’ identification and tracking. In our project, it was developed a patient tracking platform (PTP) where first responders triage the patients with an electronic tag which report the location and some information of each patient during his/her movement. This platform includes: 1) near field communication (NFC) tags (ISO 14443), 2) smart mobile phones (Android-base version 4.2.2), 3) Base station laptops (Windows), 4) server software, 5) Android software to use by first responders, 5) disaster command software, and 6) system architecture. Our model has been completed through literature review, Delphi technique, focus group, design the platform, and implement in an earthquake exercise. This paper presents consideration for content, function, and technologies that must apply for patient tracking in medical emergencies situations. It is demonstrated the robustness of the patient tracking platform (PTP) in tracking 6 patients in a simulated earthquake situation in the yard of the relief and rescue department of Isfahan’s Red Crescent.

Keywords: test and evaluation, patient tracking platform, earthquake, simulation

Procedia PDF Downloads 125
10217 Design and Fabrication of Stiffness Reduced Metallic Locking Compression Plates through Topology Optimization and Additive Manufacturing

Authors: Abdulsalam A. Al-Tamimi, Chris Peach, Paulo Rui Fernandes, Paulo J. Bartolo

Abstract:

Bone fixation implants currently used to treat traumatic fractured bones and to promote fracture healing are built with biocompatible metallic materials such as stainless steel, cobalt chromium and titanium and its alloys (e.g., CoCrMo and Ti6Al4V). The noticeable stiffness mismatch between current metallic implants and host bone associates with negative outcomes such as stress shielding which causes bone loss and implant loosening leading to deficient fracture treatment. This paper, part of a major research program to design the next generation of bone fixation implants, describes the combined use of three-dimensional (3D) topology optimization (TO) and additive manufacturing powder bed technology (Electron Beam Melting) to redesign and fabricate the plates based on the current standard one (i.e., locking compression plate). Topology optimization is applied with an objective function to maximize the stiffness and constraint by volume reductions (i.e., 25-75%) in order to obtain optimized implant designs with reduced stress shielding phenomenon, under different boundary conditions (i.e., tension, bending, torsion and combined loads). The stiffness of the original and optimised plates are assessed through a finite-element study. The TO results showed actual reduction in the stiffness for most of the plates due to the critical values of volume reduction. Additionally, the optimized plates fabricated using powder bed techniques proved that the integration between the TO and additive manufacturing presents the capability of producing stiff reduced plates with acceptable tolerances.

Keywords: additive manufacturing, locking compression plate, finite element, topology optimization

Procedia PDF Downloads 187
10216 Optimization of Perfusion Distribution in Custom Vascular Stent-Grafts Through Patient-Specific CFD Models

Authors: Scott M. Black, Craig Maclean, Pauline Hall Barrientos, Konstantinos Ritos, Asimina Kazakidi

Abstract:

Aortic aneurysms and dissections are leading causes of death in cardiovascular disease. Both inevitably lead to hemodynamic instability without surgical intervention in the form of vascular stent-graft deployment. An accurate description of the aortic geometry and blood flow in patient-specific cases is vital for treatment planning and long-term success of such grafts, as they must generate physiological branch perfusion and in-stent hemodynamics. The aim of this study was to create patient-specific computational fluid dynamics (CFD) models through a multi-modality, multi-dimensional approach with boundary condition optimization to predict branch flow rates and in-stent hemodynamics in custom stent-graft configurations. Three-dimensional (3D) thoracoabdominal aortae were reconstructed from four-dimensional flow-magnetic resonance imaging (4D Flow-MRI) and computed tomography (CT) medical images. The former employed a novel approach to generate and enhance vessel lumen contrast via through-plane velocity at discrete, user defined cardiac time steps post-hoc. To produce patient-specific boundary conditions (BCs), the aortic geometry was reduced to a one-dimensional (1D) model. Thereafter, a zero-dimensional (0D) 3-Element Windkessel model (3EWM) was coupled to each terminal branch to represent the distal vasculature. In this coupled 0D-1D model, the 3EWM parameters were optimized to yield branch flow waveforms which are representative of the 4D Flow-MRI-derived in-vivo data. Thereafter, a 0D-3D CFD model was created, utilizing the optimized 3EWM BCs and a 4D Flow-MRI-obtained inlet velocity profile. A sensitivity analysis on the effects of stent-graft configuration and BC parameters was then undertaken using multiple stent-graft configurations and a range of distal vasculature conditions. 4D Flow-MRI granted unparalleled visualization of blood flow throughout the cardiac cycle in both the pre- and postsurgical states. Segmentation and reconstruction of healthy and stented regions from retrospective 4D Flow-MRI images also generated 3D models with geometries which were successfully validated against their CT-derived counterparts. 0D-1D coupling efficiently captured branch flow and pressure waveforms, while 0D-3D models also enabled 3D flow visualization and quantification of clinically relevant hemodynamic parameters for in-stent thrombosis and graft limb occlusion. It was apparent that changes in 3EWM BC parameters had a pronounced effect on perfusion distribution and near-wall hemodynamics. Results show that the 3EWM parameters could be iteratively changed to simulate a range of graft limb diameters and distal vasculature conditions for a given stent-graft to determine the optimal configuration prior to surgery. To conclude, this study outlined a methodology to aid in the prediction post-surgical branch perfusion and in-stent hemodynamics in patient specific cases for the implementation of custom stent-grafts.

Keywords: 4D flow-MRI, computational fluid dynamics, vascular stent-grafts, windkessel

Procedia PDF Downloads 162
10215 Systematic Analysis of Immune Response to Biomaterial Surface Characteristics

Authors: Florian Billing, Soren Segan, Meike Jakobi, Elsa Arefaine, Aliki Jerch, Xin Xiong, Matthias Becker, Thomas Joos, Burkhard Schlosshauer, Ulrich Rothbauer, Nicole Schneiderhan-Marra, Hanna Hartmann, Christopher Shipp

Abstract:

The immune response plays a major role in implant biocompatibility, but an understanding of how to design biomaterials for specific immune responses is yet to be achieved. We aimed to better understand how changing certain material properties can drive immune responses. To this end, we tested immune response to experimental implant coatings that vary in specific characteristics. A layer-by-layer approach was employed to vary surface charge and wettability. Human-based in vitro models (THP-1 macrophages and primary peripheral blood mononuclear cells (PBMCS)) were used to assess immune responses using multiplex cytokine analysis, flow cytometry (CD molecule expression) and microscopy (cell morphology). We observed dramatic differences in immune response due to specific alterations in coating properties. For example altering the surface charge of coating A from anionic to cationic resulted in the substantial elevation of the pro-inflammatory molecules IL-1beta, IL-6, TNF-alpha and MIP-1beta, while the pro-wound healing factor VEGF was significantly down-regulated. We also observed changes in cell surface marker expression in relation to altered coating properties, such as CD16 on NK Cells and HLA-DR on monocytes. We furthermore observed changes in the morphology of THP-1 macrophages following cultivation on different coatings. A correlation between these morphological changes and the cytokine expression profile is ongoing. Targeted changes in biomaterial properties can produce vast differences in immune response. The properties of the coatings examined here may, therefore, be a method to direct specific biological responses in order to improve implant biocompatibility.

Keywords: biomaterials, coatings, immune system, implants

Procedia PDF Downloads 170