Search results for: hdd servo control
10066 Multiscale Entropy Analysis of Electroencephalogram (EEG) of Alcoholic and Control Subjects
Authors: Lal Hussain, Wajid Aziz, Imtiaz Ahmed Awan, Sharjeel Saeed
Abstract:
Multiscale entropy analysis (MSE) is a useful technique recently developed to quantify the dynamics of physiological signals at different time scales. This study is aimed at investigating the electroencephalogram (EEG) signals to analyze the background activity of alcoholic and control subjects by inspecting various coarse-grained sequences formed at different time scales. EEG recordings of alcoholic and control subjects were taken from the publically available machine learning repository of University of California (UCI) acquired using 64 electrodes. The MSE analysis was performed on the EEG data acquired from all the electrodes of alcoholic and control subjects. Mann-Whitney rank test was used to find significant differences between the groups and result were considered statistically significant for p-values<0.05. The area under receiver operator curve was computed to find the degree separation between the groups. The mean ranks of MSE values at all the times scales for all electrodes were higher control subject as compared to alcoholic subjects. Higher mean ranks represent higher complexity and vice versa. The finding indicated that EEG signals acquired through electrodes C3, C4, F3, F7, F8, O1, O2, P3, T7 showed significant differences between alcoholic and control subjects at time scales 1 to 5. Moreover, all electrodes exhibit significance level at different time scales. Likewise, the highest accuracy and separation was obtained at the central region (C3 and C4), front polar regions (P3, O1, F3, F7, F8 and T8) while other electrodes such asFp1, Fp2, P4 and F4 shows no significant results.Keywords: electroencephalogram (EEG), multiscale sample entropy (MSE), Mann-Whitney test (MMT), Receiver Operator Curve (ROC), complexity analysis
Procedia PDF Downloads 37610065 Cognitive Control Moderates the Concurrent Effect of Autistic and Schizotypal Traits on Divergent Thinking
Authors: Julie Ramain, Christine Mohr, Ahmad Abu-Akel
Abstract:
Divergent thinking—a cognitive component of creativity—and particularly the ability to generate unique and novel ideas, has been linked to both autistic and schizotypal traits. However, to our knowledge, the concurrent effect of these trait dimensions on divergent thinking has not been investigated. Moreover, it has been suggested that creativity is associated with different types of attention and cognitive control, and consequently how information is processed in a given context. Intriguingly, consistent with the diametric model, autistic and schizotypal traits have been associated with contrasting attentional and cognitive control styles. Positive schizotypal traits have been associated with reactive cognitive control and attentional flexibility, while autistic traits have been associated with proactive cognitive control and the increased focus of attention. The current study investigated the relationship between divergent thinking, autistic and schizotypal traits and cognitive control in a non-clinical sample of 83 individuals (Males = 42%; Mean age = 22.37, SD = 2.93), sufficient to detect a medium effect size. Divergent thinking was evaluated in an adapted version of-of the Figural Torrance Test of Creative Thinking. Crucially, since we were interested in testing divergent thinking productivity across contexts, participants were asked to generate items from basic shapes in four different contexts. The variance of the proportion of unique to total responses across contexts represented a measure of context adaptability, with lower variance indicating increased context adaptability. Cognitive control was estimated with the Behavioral Proactive Index of the AX-CPT task, with higher scores representing the ability to actively maintain goal-relevant information in a sustained/anticipatory manner. Autistic and schizotypal traits were assessed with the Autism Quotient (AQ) and the Community Assessment of Psychic Experiences (CAPE-42). Generalized linear models revealed a 3-way interaction of autistic and positive schizotypal traits, and proactive cognitive control, associated with increased context adaptability. Specifically, the concurrent effect of autistic and positive schizotypal traits on increased context adaptability was moderated by the level of proactive control and was only significant when proactive cognitive control was high. Our study reveals that autistic and positive schizotypal traits interactively facilitate the capacity to generate unique ideas across various contexts. However, this effect depends on cognitive control mechanisms indicative of the ability to proactively maintain attention when needed. The current results point to a unique profile of divergent thinkers who have the ability to respectively tap both systematic and flexible processing modes within and across contexts. This is particularly intriguing as such combination of phenotypes has been proposed to explain the genius of Beethoven, Nash, and Newton.Keywords: autism, schizotypy, creativity, cognitive control
Procedia PDF Downloads 13710064 Simulation of an Active Controlled Vibration Isolation System for Astronaut’s Exercise Platform
Authors: Shield B. Lin, Sameer Abdali
Abstract:
Computer simulations were performed using MATLAB/Simulink for a vibration isolation system for astronaut’s exercise platform. Simulation parameters initially were based on an on-going experiment in a laboratory at NASA Johnson Space Center. The authors expanded later simulations to include other parameters. A discrete proportional-integral-derivative controller with a low-pass filter commanding a linear actuator served as the active control unit to push and pull a counterweight in balancing the disturbance forces. A spring-damper device is used as an optional passive control unit. Simulation results indicated such design could achieve near complete vibration isolation with small displacements of the exercise platform.Keywords: control, counterweight, isolation, vibration
Procedia PDF Downloads 14910063 Study of Flow-Induced Noise Control Effects on Flat Plate through Biomimetic Mucus Injection
Authors: Chen Niu, Xuesong Zhang, Dejiang Shang, Yongwei Liu
Abstract:
Fishes can secrete high molecular weight fluid on their body skin to enable their rapid movement in the water. In this work, we employ a hybrid method that combines Computational Fluid Dynamics (CFD) and Finite Element Method (FEM) to investigate the effects of different mucus viscosities and injection velocities on fluctuation pressure in the boundary layer and flow-induced structural vibration noise of a flat plate model. To accurately capture the transient flow distribution on the plate surface, we use Large Eddy Simulation (LES) while the mucus inlet is positioned at a sufficient distance from the model to ensure effective coverage. Mucus injection is modeled using the Volume of Fluid (VOF) method for multiphase flow calculations. The results demonstrate that mucus control of pulsating pressure effectively reduces flow-induced structural vibration noise, providing an approach for controlling flow-induced noise in underwater vehicles.Keywords: mucus, flow control, noise control, flow-induced noise
Procedia PDF Downloads 14510062 Control HVAC Parameters by Brain Emotional Learning Based Intelligent Controller (BELBIC)
Authors: Javad Abdi, Azam Famil Khalili
Abstract:
Modeling emotions have attracted much attention in recent years, both in cognitive psychology and design of artificial systems. However, it is a negative factor in decision-making; emotions have shown to be a strong faculty for making fast satisfying decisions. In this paper, we have adapted a computational model based on the limbic system in the mammalian brain for control engineering applications. Learning in this model based on Temporal Difference (TD) Learning, we applied the proposed controller (termed BELBIC) for a simple model of a submarine. The model was supposed to reach the desired depth underwater. Our results demonstrate excellent control action, disturbance handling, and system parameter robustness for TDBELBIC. The proposal method, regarding the present conditions, the system action in the part and the controlling aims, can control the system in a way that these objectives are attained in the least amount of time and the best way.Keywords: artificial neural networks, temporal difference, brain emotional learning based intelligent controller, heating- ventilating and air conditioning
Procedia PDF Downloads 43310061 Investigations into Effect of Neural Network Predictive Control of UPFC for Improving Transient Stability Performance of Multimachine Power System
Authors: Sheela Tiwari, R. Naresh, R. Jha
Abstract:
The paper presents an investigation into the effect of neural network predictive control of UPFC on the transient stability performance of a multi-machine power system. The proposed controller consists of a neural network model of the test system. This model is used to predict the future control inputs using the damped Gauss-Newton method which employs ‘backtracking’ as the line search method for step selection. The benchmark 2 area, 4 machine system that mimics the behavior of large power systems is taken as the test system for the study and is subjected to three phase short circuit faults at different locations over a wide range of operating conditions. The simulation results clearly establish the robustness of the proposed controller to the fault location, an increase in the critical clearing time for the circuit breakers and an improved damping of the power oscillations as compared to the conventional PI controller.Keywords: identification, neural networks, predictive control, transient stability, UPFC
Procedia PDF Downloads 37110060 Level of Knowledge, Attitude, Perceived Behavior Control, Subjective Norm and Behavior of Household Solid Waste towards Zero Waste Management among Malaysian Consumer
Authors: M. J. Zuroni, O. Syuhaily, M. A. Afida Mastura, M. S. Roslina, A. K. Nurul Aini
Abstract:
The impact of country development has caused an increase of solid waste. The increase in population causes of excess usage thus effecting the sustainable environment. Zero waste management involves maximizing practices of recycling and minimizing residual waste. This paper seeks to analyze the relationship between knowledge, attitude, perceived behavior control, subjective norm and behavior of household solid waste towards household solid waste management among urban households in 8 states that have been implemented and enforced regulations under the Solid Waste Management and Public Cleansing Act 2007 (Act 672) in Malaysia. A total of respondents are 605 and we used a purposive sampling for location and simple sampling for sample size. Data collected by using self-administered questionnaire and were analyzed using SPSS software. The Pearson Correlation Test is to examine the relationship between four variables. Results show that knowledge scores are high because they have an awareness of the importance of managing solid waste. For attitude, perceived behavior control, subjective norm and behavioral scores at a moderate level in solid waste management activities. The findings show that there is a significant relationship between knowledge and behavior of household solid waste (r = 0.136 **, p = 0.001), there is a significant relationship between attitude and behavior (r = 0.238 **, p = 0.000), there is a significant relationship between perceived behavior control and behavior (r = 0.516 **, p = 0.000) and there is a significant relationship between subjective norm and behavior (r = 0.494 **, p = 0.000). The conclusion is that there is a relationship between knowledge, attitude, perceived behavior control and subjective norm toward the behavior of household solid waste management. Therefore, in the findings of the study, all parties including the government should work together to enhance the knowledge, attitude, perceived behavior control and behavior of household solid waste management in other states that have not implemented and enforced regulations under the Solid Waste and Public Cleansing Management Act 2007 (Act 672).Keywords: solid waste management, knowledge, attitude, perceived behavior control, subjective norm, behavior
Procedia PDF Downloads 33210059 Integrated Gesture and Voice-Activated Mouse Control System
Authors: Dev Pratap Singh, Harshika Hasija, Ashwini S.
Abstract:
The project aims to provide a touchless, intuitive interface for human-computer interaction, enabling users to control their computers using hand gestures and voice commands. The system leverages advanced computer vision techniques using the Media Pipe framework and OpenCV to detect and interpret real-time hand gestures, transforming them into mouse actions such as clicking, dragging, and scrolling. Additionally, the integration of a voice assistant powered by the speech recognition library allows for seamless execution of tasks like web searches, location navigation, and gesture control in the system through voice commands.Keywords: gesture recognition, hand tracking, machine learning, convolutional neural networks, natural language processing, voice assistant
Procedia PDF Downloads 1010058 The Effects of Critical Incident Stress Debriefing and Other Related Interventions on the Psychological Recovery of Earthquake Survivors
Authors: Joyce Fernandez
Abstract:
This study examined the effects of critical incident stress debriefing and other related interventions on the psychological recovery of earthquake survivors. It is a mixed experimental and qualitative study using post-test only control group design and focus group discussion. After the conduct of critical incident stress debriefing activities and other related interventions in the form of counseling and psychiatric treatment to the survivors of a 6.9 magnitude earthquake, a post-test measuring the level of psychological recovery was given to randomized participants categorized as intervention and control groups. Using the traumatic assessment and belief scale as instrument for the quantitative aspect in order to gauge recovery in the psychological need areas of safety, trust, esteem, intimacy and control, the findings are the following: Intervention group participants have relatively better adjustment along the five psychological need areas compared to the control group participants; there is no significant difference in the psychological recovery among female and male participants of the invention and control groups and; there are significant differences between intervention and control groups in the psychological need areas of self-safety, self-trust, other-trust, self-esteem, and self-intimacy. Using a guided interview for the qualitative data, the themes derived are the following. Safety: The world is an unsafe place to live because of the calamities. Trust: Trust and dependence are anchored on the family. Esteem: Participants are having confused self-worth. Intimacy: Participants are thriving on attachment with their family. Control: Participants have unaltered desire to help but feeling restricted because of personal and logistical concerns.As an outcome of the study a Psychosocial Care Program for Individuals, Families and Communities Affected by Disaster and Trauma was proposed.Keywords: critical incident stress debriefing, earthquake survivors, psychological recovery, related interventions
Procedia PDF Downloads 29310057 Coastal Erosion Control Alternatives with Geosynthetics: Study Case of Ponta Negra Beach, Natal, Brazil
Authors: M. A. Medeiros, A. A. N. Dantas, F. A. N. França, R. F. Amaral
Abstract:
There are several alternatives of coastal erosion control with geosynthetics. As an important stage of any Civil Engineering project, literature review is necessary in order to evaluate these alternatives and to guide the decisions. Ponta Negra beachfront has a very intensive urban pressure. In addition, a very short sand area induces high intensity erosion processes. Different attempts of solving the problem were already built. However, erosion issues are still an important concern since these structures collapsed. Geosynthetics present a great potential to be applied in this area. In order to study coastal erosion control alternatives with the use of geosynthetics, this paper presents a literature review about this subject. Several studies were collected in which beach conditions are similar to those found in Ponta Negra beach. It was possible to evaluate the alternatives that might be used in the area. Further studies include the application of such techniques in pilot areas and the evaluation of the erosion process. Finally, the best alternative for futures studies on Ponta Negra beach is geocontainers of geotextiles.Keywords: geosynthetics, coastal erosion control, alternatives, Ponta Negra beach
Procedia PDF Downloads 15210056 Comparison of Effectiveness When Ketamine was Used as an Adjuvant in Intravenous Patient-Controlled Analgesia Used to Control Cancer Pain
Authors: Donghee Kang
Abstract:
Background: Cancer pain is very difficult to control as the mechanism of pain is varied, and the patient has several co-morbidities. The use of Intravenous Patient-Controlled Analgesia (IV-PCA) can effectively control underlying pain and breakthrough pain. Ketamine is used in many pain patients due to its unique analgesic effect. In this study, it was checked whether there was a difference in the amount of analgesic usage, pain control degree, and side effects between patients who controlled pain with fentanyl-based IV-PCA and those who added Ketamine for pain control. Methods: Among the patients referred to this department for cancer pain, IV-PCA was applied to patients who were taking sufficient oral analgesics but could not control them or had blood clotting disorders that made the procedure difficult, and this patient group was targeted. In IV-PCA, 3000 mcg of Fentanyl, 160 mg of Nefopam, and 0.3 mg of Ramosetrone were mixed with normal saline to make a total volume of 100 ml. Group F used this IV-PCA as it is, and group K mixed 250 mg of Ketamine with normal saline to make a total volume of 100 ml. For IV-PCA, the basal rate was 0.5ml/h, the bolus was set to 1ml when pressed once, and the lockout time was set to 15 minutes. If pain was not controlled after IV-PCA application, 500 mcg of Fentanyl was added, and if excessive sedation or breathing difficulties occurred, the use was stopped for one hour. After that, the degree of daily pain control, analgesic usage, and side effects were investigated for seven days using this IV-PCA. Results: There was no difference between the two groups in the demographic data. Both groups had adequate pain control. Initial morphine milligram equivalents did not differ between the two groups, but the total amount of Fentanyl used for seven days was significantly different between the two groups [p=0.014], and group F used more Fentanyl through IV-PCA. In addition, the amount of sleeping pills used during the seven days was higher in Group F [p<0.01]. Overall, there was no difference in the frequency of side effects between the two groups, but the nausea was more frequent in Group F [p=0.031]. Discussion: When the two groups were compared, pain control was good in both groups. This seems to be because Fentanyl-based IV-PCA showed an adequate pain control effect. However, there was a significant difference in the total amount of opioid (Fentanyl) used, which is thought to be the opioid-sparing effect of Ketamine. Also, among the side effects, nausea was significantly less, which is thought to be possible because the amount of opioids used in the Ketamine group was small. The frequency of requesting sleeping pills was significantly less in the group using Ketamine, and it seems that Ketamine also helped improve sleep quality. In conclusion, using Ketamine with an opioid to control pain seems to have advantages. IV-PCA, which can be used effectively when other procedures are difficult, is more effective and safer when used together with Ketamine than opioids alone.Keywords: cancer pain, intravenous patient-controlled analgesia, Ketamine, opioid
Procedia PDF Downloads 8210055 Increasing the Forecasting Fidelity of Current Collection System Operating Capability by Means of Contact Pressure Simulation Modelling
Authors: Anton Golubkov, Gleb Ermachkov, Aleksandr Smerdin, Oleg Sidorov, Victor Philippov
Abstract:
Current collection quality is one of the limiting factors when increasing trains movement speed in the rail sector. With the movement speed growth, the impact forces on the current collector from the rolling stock and the aerodynamic influence increase, which leads to the spread in the contact pressure values, separation of the current collector head from the contact wire, contact arcing and excessive wear of the contact elements. The upcoming trend in resolving this issue is the use of the automatic control systems providing stabilization of the contact pressure value. The present paper considers the features of the contemporary automatic control systems of the current collector’s pressure; their major disadvantages have been stated. A scheme of current collector pressure automatic control has been proposed, distinguished by a proactive influence on undesirable effects. A mathematical model of contact strips wearing has been presented, obtained in accordance with the provisions of the central composition rotatable design program. The analysis of the obtained dependencies has been carried out. The procedures for determining the optimal current collector pressure on the contact wire and the pressure control principle in the pneumatic drive have been described.Keywords: contact strip, current collector, high-speed running, program control, wear
Procedia PDF Downloads 14510054 The Effect of Nutrition Education on Glycemic and Lipidemic Control in Iranian Patients with Type 2 Diabetes
Authors: Samira Rabiei, Faezeh Askari, Reza Rastmanesh
Abstract:
Objective: To evaluate the effects of nutrition education and adherence to a healthy diet on glycemic and lipidemic control in patients with T2DM. Material and Methods: A randomized controlled trial was conducted on 494 patients with T2DM, aged 14-87 years from both sexes who were selected by convenience sampling from referees to Aliebneabitaleb hospital in Ghom. The participants were divided into two 247 person groups by stratified randomization. Both groups received a diet adjusted based on ideal body weight, and the intervention group was additionally educated about healthy food choices regarding diabetes. Information on medications, psychological factors, diet and physical activity was obtained from questionnaires. Blood samples were collected to measure FBS, 2 hPG, HbA1c, cholesterol, and triglyceride. After 2 months, weight and biochemical parameters were measured again. Independent T-test, Mann-Whitney, Chi-square, and Wilcoxon were used as appropriate. Logistic regression was used to determine the odds ratio of abnormal glycemic and lipidemic control according to the intervention. Results: The mean weight, FBS, 2 hPG, cholesterol and triglyceride after intervention were significantly lower than before that (p < 0.05). Discussion: Nutrition education plus a weigh reducer diet is more effective on glycemic and lipidemic control than a weight reducer diet, alone.Keywords: type 2 diabetes mellitus, nutrition education, glycemic control, lipid profile
Procedia PDF Downloads 20710053 Reductive Control in the Management of Redundant Actuation
Authors: Mkhinini Maher, Knani Jilani
Abstract:
We present in this work the performances of a mobile omnidirectional robot through evaluating its management of the redundancy of actuation. Thus we come to the predictive control implemented. The distribution of the wringer on the robot actions, through the inverse pseudo of Moore-Penrose, corresponds to a -geometric- distribution of efforts. We will show that the load on vehicle wheels would not be equi-distributed in terms of wheels configuration and of robot movement. Thus, the threshold of sliding is not the same for the three wheels of the vehicle. We suggest exploiting the redundancy of actuation to reduce the risk of wheels sliding and to ameliorate, thereby, its accuracy of displacement. This kind of approach was the subject of study for the legged robots.Keywords: mobile robot, actuation, redundancy, omnidirectional, inverse pseudo moore-penrose, reductive control
Procedia PDF Downloads 51010052 Performance Investigation of Unmanned Aerial Vehicles Attitude Control Based on Modified PI-D and Nonlinear Dynamic Inversion
Authors: Ebrahim H. Kapeel, Ahmed M. Kamel, Hossam Hendy, Yehia Z. Elhalwagy
Abstract:
Interest in autopilot design has been raised intensely as a result of recent advancements in Unmanned Aerial vehicles (UAVs). Due to the enormous number of applications that UAVs can achieve, the number of applied control theories used for them has increased in recent years. These small fixed-wing UAVs are suffering high non-linearity, sensitivity to disturbances, and coupling effects between their channels. In this work, the nonlinear dynamic inversion (NDI) control law is designed for a nonlinear small fixed-wing UAV model. The NDI is preferable for varied operating conditions, there is no need for a scheduling controller. Moreover, it’s applicable for high angles of attack. For the designed flight controller validation, a nonlinear Modified PI-D controller is performed with our model. A comparative study between both controllers is achieved to evaluate the NDI performance. Simulation results and analysis are proposed to illustrate the effectiveness of the designed controller based on NDI.Keywords: attitude control, nonlinear PID, dynamic inversion
Procedia PDF Downloads 11010051 Computer-Assisted Management of Building Climate and Microgrid with Model Predictive Control
Authors: Vinko Lešić, Mario Vašak, Anita Martinčević, Marko Gulin, Antonio Starčić, Hrvoje Novak
Abstract:
With 40% of total world energy consumption, building systems are developing into technically complex large energy consumers suitable for application of sophisticated power management approaches to largely increase the energy efficiency and even make them active energy market participants. Centralized control system of building heating and cooling managed by economically-optimal model predictive control shows promising results with estimated 30% of energy efficiency increase. The research is focused on implementation of such a method on a case study performed on two floors of our faculty building with corresponding sensors wireless data acquisition, remote heating/cooling units and central climate controller. Building walls are mathematically modeled with corresponding material types, surface shapes and sizes. Models are then exploited to predict thermal characteristics and changes in different building zones. Exterior influences such as environmental conditions and weather forecast, people behavior and comfort demands are all taken into account for deriving price-optimal climate control. Finally, a DC microgrid with photovoltaics, wind turbine, supercapacitor, batteries and fuel cell stacks is added to make the building a unit capable of active participation in a price-varying energy market. Computational burden of applying model predictive control on such a complex system is relaxed through a hierarchical decomposition of the microgrid and climate control, where the former is designed as higher hierarchical level with pre-calculated price-optimal power flows control, and latter is designed as lower level control responsible to ensure thermal comfort and exploit the optimal supply conditions enabled by microgrid energy flows management. Such an approach is expected to enable the inclusion of more complex building subsystems into consideration in order to further increase the energy efficiency.Keywords: price-optimal building climate control, Microgrid power flow optimisation, hierarchical model predictive control, energy efficient buildings, energy market participation
Procedia PDF Downloads 46510050 Designing an Operational Control System for the Continuous Cycle of Industrial Technological Processes Using Fuzzy Logic
Authors: Teimuraz Manjapharashvili, Ketevani Manjaparashvili
Abstract:
Fuzzy logic is a modeling method for complex or ill-defined systems and is a relatively new mathematical approach. Its basis is to consider overlapping cases of parameter values and define operations to manipulate these cases. Fuzzy logic can successfully create operative automatic management or appropriate advisory systems. Fuzzy logic techniques in various operational control technologies have grown rapidly in the last few years. Fuzzy logic is used in many areas of human technological activity. In recent years, fuzzy logic has proven its great potential, especially in the automation of industrial process control, where it allows to form of a control design based on the experience of experts and the results of experiments. The engineering of chemical technological processes uses fuzzy logic in optimal management, and it is also used in process control, including the operational control of continuous cycle chemical industrial, technological processes, where special features appear due to the continuous cycle and correct management acquires special importance. This paper discusses how intelligent systems can be developed, in particular, how fuzzy logic can be used to build knowledge-based expert systems in chemical process engineering. The implemented projects reveal that the use of fuzzy logic in technological process control has already given us better solutions than standard control techniques. Fuzzy logic makes it possible to develop an advisory system for decision-making based on the historical experience of the managing operator and experienced experts. The present paper deals with operational control and management systems of continuous cycle chemical technological processes, including advisory systems. Because of the continuous cycle, many features are introduced in them compared to the operational control of other chemical technological processes. Among them, there is a greater risk of transitioning to emergency mode; the return from emergency mode to normal mode must be done very quickly due to the impossibility of stopping the technological process due to the release of defective products during this period (i.e., receiving a loss), accordingly, due to the need for high qualification of the operator managing the process, etc. For these reasons, operational control systems of continuous cycle chemical technological processes have been specifically discussed, as they are different systems. Special features of such systems in control and management were brought out, which determine the characteristics of the construction of control and management systems. To verify the findings, the development of an advisory decision-making information system for operational control of a lime kiln using fuzzy logic, based on the creation of a relevant expert-targeted knowledge base, was discussed. The control system has been implemented in a real lime production plant with a lime burn kiln, which has shown that suitable and intelligent automation improves operational management, reduces the risks of releasing defective products, and, therefore, reduces costs. The special advisory system was successfully used in the said plant both for the improvement of operational management and, if necessary, for the training of new operators due to the lack of an appropriate training institution.Keywords: chemical process control systems, continuous cycle industrial technological processes, fuzzy logic, lime kiln
Procedia PDF Downloads 2810049 Double Fortified Salt-An Effective Measure to Prevent Micronutrient Deficiencies in Indian Pregnant Women
Authors: Kejal Joshi Reddy, Sirimavo Nair
Abstract:
Micronutrient malnutrition affects pregnant women and children extremely with reference to growth manifestations in gestation as well as after birth. Early fetal development affected by iodine and iron deficiency leads to poor life quality. Various researchers have found interesting interrelations between iron and iodine. A few studies on impact assessment of DFS supplementation during pregnancy have been reported in India. Aim To provide meaningful contribution by assessing the efficacy of DFS supplementation on iodine and iron status of pregnant women. Design An interventional study. Setting A semi government hospital of urban Vadodara. Subjects Pregnant women (n=150) enrolled during first trimester (< 12 weeks) and followed up till the end of gestation, n=75 were divided in experimental (DFS supplemented) and control (Non supplemented) group. Results Impact on iron and iodine status was assessed by Hb concentration and UIE respectively. Mean Hb improved significantly (p < 0.001) (+0.42 g/dl) in experimental group and reduced non significantly (-0.20 g/dl) in control group at the end, since DFS provided additional 93 mg of iron within 6 months. Median UIE improved non significantly (278.6 to 299.01µg/L) in experimental group and decreased significantly (p < 0.05) (376.59 to 288.66 µg/L) in control group. Conclusion DFS could improve iron and iodine status of experimental group compared to control group. It is an effective measure to control two essential micronutrient deficiencies together.Keywords: DFS supplementation, anemia, pregnancy, iodine deficiency, iron
Procedia PDF Downloads 47010048 Effect of Follicular Fluid on in vitro Maturation and Gene Expression in Ovine Oocytes
Authors: Al-Mutary M., Alhimaidi A., Al-Ghadi M. Iwamoto D., Javed Ahmad. Abdulaziz A. Al-Khedhairy
Abstract:
The aim of the present study was to evaluate the effect of ovine follicular fluid supplementation during IVM of sheep oocytes on the resumption of meiosis, glutathione (GSH) content and expression of Bax, Bcl-2, and HSPB1 genes. Sheep ovaries were collected from Riyadh slaughterhouse, KSA. Oocytes were aspirated from 3-6 mm follicles. Ovine oocytes were cultured in maturation medium with 0% (control), 10%, 20%, 40% of ovine follicular fluid for 24 h. Results indicated that the rate of oocyte maturation was significantly (P≤0.05) decreased in 40% OFF (36.87%) versus the control (61.3%), 10% OFF (63.95%) and 20% OFF (64.08%). Supplementation of 10% OFF to IVM medium induced an intra-oocyte GSH concentration significantly higher than that found in ovine oocytes cultured with 20% OFF and 40% OFF and similar to the GSH content in oocytes cultured without FF. Real time polymerase chain reaction analysis for gene expression revealed no differences in Bax, Bcl-2, HSPB1 genes between control and 10% OFF group, whereas they were strongly expressed in 20% OFF and 40% OFF (P < 0.05) when compared to the control and 10% OFF. In conclusion the addition of 10% OFF to the IVM culture of sheep oocytes is recommended to support cytoplasmic maturation and increase oocytes competence.Keywords: IVM, oocyte maturation, gene expression, follicular fluid
Procedia PDF Downloads 36210047 The Scientific Study of the Relationship Between Physicochemical and Microstructural Properties of Ultrafiltered Cheese: Protein Modification and Membrane Separation
Authors: Shahram Naghizadeh Raeisi, Ali Alghooneh
Abstract:
The loss of curd cohesiveness and syneresis are two common problems in the ultrafiltered cheese industry. In this study, by using membrane technology and protein modification, a modified cheese was developed and its properties were compared with a control sample. In order to decrease the lactose content and adjust the protein, acidity, dry matter and milk minerals, a combination of ultrafiltration, nanofiltration and reverse osmosis technologies was employed. For protein modification, a two-stage chemical and enzymatic reaction was employed before and after ultrafiltration. The physicochemical and microstructural properties of the modified ultrafiltered cheese were compared with the control one. Results showed that the modified protein enhanced the functional properties of the final cheese significantly (pvalue< 0.05), even if the protein content was 50% lower than the control one. The modified cheese showed 21 ± 0.70, 18 ± 1.10 & 25±1.65% higher hardness, cohesiveness and water-holding capacity values, respectively, than the control sample. This behavior could be explained by the developed microstructure of the gel network. Furthermore, chemical-enzymatic modification of milk protein induced a significant change in the network parameter of the final cheese. In this way, the indices of network linkage strength, network linkage density, and time scale of junctions were 10.34 ± 0.52, 68.50 ± 2.10 & 82.21 ± 3.85% higher than the control sample, whereas the distance between adjacent linkages was 16.77 ± 1.10% lower than the control sample. These results were supported by the results of the textural analysis. A non-linear viscoelastic study showed a triangle waveform stress of the modified protein contained cheese, while the control sample showed rectangular waveform stress, which suggested a better sliceability of the modified cheese. Moreover, to study the shelf life of the products, the acidity, as well as molds and yeast population, were determined in 120 days. It’s worth mentioning that the lactose content of modified cheese was adjusted at 2.5% before fermentation, while the lactose of the control one was at 4.5%. The control sample showed 8 weeks shelf life, while the shelf life of the modified cheese was 18 weeks in the refrigerator. During 18 weeks, the acidity of modified and control samples increased from 82 ± 1.50 to 94 ± 2.20 °D and 88 ± 1.64 to 194 ± 5.10 °D, respectively. The mold and yeast populations, with time, followed the semicircular shape model (R2 = 0.92, R2adj = 0.89, RMSE = 1.25). Furthermore, the mold and yeast counts and their growth rate in the modified cheese were lower than those for control one; Aforementioned result could be explained by the shortage of the source of energy for the microorganism in the modified cheese. The lactose content of the modified sample was less than 0.2 ± 0.05% at the end of fermentation, while this was 3.7 ± 0.68% in the control sample.Keywords: non-linear viscoelastic, protein modification, semicircular shape model, ultrafiltered cheese
Procedia PDF Downloads 7410046 Best Practices and Recommendations for CFD Simulation of Hydraulic Spool Valves
Authors: Jérémy Philippe, Lucien Baldas, Batoul Attar, Jean-Charles Mare
Abstract:
The proposed communication deals with the research and development of a rotary direct-drive servo valve for aerospace applications. A key challenge of the project is to downsize the electromagnetic torque motor by reducing the torque required to drive the rotary spool. It is intended to optimize the spool and the sleeve geometries by combining a Computational Fluid Dynamics (CFD) approach with commercial optimization software. The present communication addresses an important phase of the project, which consists firstly of gaining confidence in the simulation results. It is well known that the force needed to pilot a sliding spool valve comes from several physical effects: hydraulic forces, friction and inertia/mass of the moving assembly. Among them, the flow force is usually a major contributor to the steady-state (or Root Mean Square) driving torque. In recent decades, CFD has gradually become a standard simulation tool for studying fluid-structure interactions. However, in the particular case of high-pressure valve design, the authors have experienced that the calculated overall hydraulic force depends on the parameterization and options used to build and run the CFD model. To solve this issue, the authors have selected the standard case of the linear spool valve, which is addressed in detail in numerous scientific references (analytical models, experiments, CFD simulations). The first CFD simulations run by the authors have shown that the evolution of the equivalent discharge coefficient vs. Reynolds number at the metering orifice corresponds well to the values that can be predicted by the classical analytical models. Oppositely, the simulated flow force was found to be quite different from the value calculated analytically. This drove the authors to investigate minutely the influence of the studied domain and the setting of the CFD simulation. It was firstly shown that the flow recirculates in the inlet and outlet channels if their length is not sufficient regarding their hydraulic diameter. The dead volume on the uncontrolled orifice side also plays a significant role. These examples highlight the influence of the geometry of the fluid domain considered. The second action was to investigate the influence of the type of mesh, the turbulence models and near-wall approaches, and the numerical solver and discretization scheme order. Two approaches were used to determine the overall hydraulic force acting on the moving spool. First, the force was deduced from the momentum balance on a control domain delimited by the valve inlet and outlet and the spool walls. Second, the overall hydraulic force was calculated from the integral of pressure and shear forces acting at the boundaries of the fluid domain. This underlined the significant contribution of the viscous forces acting on the spool between the inlet and outlet orifices, which are generally not considered in the literature. This also emphasized the influence of the choices made for the implementation of CFD calculation and results analysis. With the step-by-step process adopted to increase confidence in the CFD simulations, the authors propose a set of best practices and recommendations for the efficient use of CFD to design high-pressure spool valves.Keywords: computational fluid dynamics, hydraulic forces, servovalve, rotary servovalve
Procedia PDF Downloads 4310045 Design and Development of Ssvep-Based Brain-Computer Interface for Limb Disabled Patients
Authors: Zerihun Ketema Tadesse, Dabbu Suman Reddy
Abstract:
Brain-Computer Interfaces (BCIs) give the possibility for disabled people to communicate and control devices. This work aims at developing steady-state visual evoked potential (SSVEP)-based BCI for patients with limb disabilities. In hospitals, devices like nurse emergency call devices, lights, and TV sets are what patients use most frequently, but these devices are operated manually or using the remote control. Thus, disabled patients are not able to operate these devices by themselves. Hence, SSVEP-based BCI system that can allow disabled patients to control nurse calling device and other devices is proposed in this work. Portable LED visual stimulator that flickers at specific frequencies of 7Hz, 8Hz, 9Hz and 10Hz were developed as part of this project. Disabled patients can stare at specific flickering LED of visual stimulator and Emotiv EPOC used to acquire EEG signal in a non-invasive way. The acquired EEG signal can be processed to generate various control signals depending upon the amplitude and duration of signal components. MATLAB software is used for signal processing and analysis and also for command generation. Arduino is used as a hardware interface device to receive and transmit command signals to the experimental setup. Therefore, this study is focused on the design and development of Steady-state visually evoked potential (SSVEP)-based BCI for limb disabled patients, which helps them to operate and control devices in the hospital room/wards.Keywords: SSVEP-BCI, Limb Disabled Patients, LED Visual Stimulator, EEG signal, control devices, hospital room/wards
Procedia PDF Downloads 22110044 Lateral Torsional Buckling: Tests on Glued Laminated Timber Beams
Authors: Vera Wilden, Benno Hoffmeister, Markus Feldmann
Abstract:
Glued laminated timber (glulam) is a preferred choice for long span girders, e.g., for gyms or storage halls. While the material provides sufficient strength to resist the bending moments, large spans lead to increased slenderness of such members and to a higher susceptibility to stability issues, in particular to lateral torsional buckling (LTB). Rules for the determination of the ultimate LTB resistance are provided by Eurocode 5. The verifications of the resistance may be performed using the so called equivalent member method or by means of theory 2nd order calculations (direct method), considering equivalent imperfections. Both methods have significant limitations concerning their applicability; the equivalent member method is limited to rather simple cases; the direct method is missing detailed provisions regarding imperfections and requirements for numerical modeling. In this paper, the results of a test series on slender glulam beams in three- and four-point bending are presented. The tests were performed in an innovative, newly developed testing rig, allowing for a very precise definition of loading and boundary conditions. The load was introduced by a hydraulic jack, which follows the lateral deformation of the beam by means of a servo-controller, coupled with the tested member and keeping the load direction vertically. The deformation-controlled tests allowed for the identification of the ultimate limit state (governed by elastic stability) and the corresponding deformations. Prior to the tests, the structural and geometrical imperfections were determined and used later in the numerical models. After the stability tests, the nearly undamaged members were tested again in pure bending until reaching the ultimate moment resistance of the cross-section. These results, accompanied by numerical studies, were compared to resistance values obtained using both methods according to Eurocode 5.Keywords: experimental tests, glued laminated timber, lateral torsional buckling, numerical simulation
Procedia PDF Downloads 23710043 An Examination of Internal Control System, Executive Duality and Audit Alarm Committee of Listed Nigerian Companies
Authors: Mansur Lubabah Kwanbo
Abstract:
Existing literatures have demonstrated the importance of executive duality (ED) and audit committee (AC) in the financial growth of companies. To some extent this points to corporate governance mechanism aiming at addressing makers and implementers of company policies to be centered on promoting only company objectives. However, furthering organizational objectives needs an adequate structure of control to realize that. Recent development in the various industries in Nigeria have indicated the internal control system (ICS)has not been able to adequately address most of the activities that results in ills of sustaining growth for these industries. It is from this premise the study has as one of its objective to determine the extent to which ICS significantly relates to ED and AC in listed Nigerian corporation. Data were sourced from 308 financial statements and accounts of the corporations that made the sample of the study. Logistic regression aided the test of the hypothesis formulated for the study. Findings revealed a significant relationship between the study variables. The study concludes that the internal control system (ICS) is effective despite the bifurcation of executive duality (ED) and the presence of the Audit Committee (AC) to the extent of preventing ills that encourage lack of sustainability of company’s growth. Sustaining legitimate policies that translate into huge earnings, and create value to stake holders should be pursued.Keywords: audit committee (AC), executive duality (ED), internal control system (ICS), Nigeria
Procedia PDF Downloads 29510042 Optimal Trajectory Finding of IDP Ventilation Control with Outdoor Air Information and Indoor Health Risk Index
Authors: Minjeong Kim, Seungchul Lee, Iman Janghorban Esfahani, Jeong Tai Kim, ChangKyoo Yoo
Abstract:
A trajectory of set-point of ventilation control systems plays an important role for efficient ventilation inside subway stations since it affects the level of indoor air pollutants and ventilation energy consumption. To maintain indoor air quality (IAQ) at a comfortable range with lower ventilation energy consumption, the optimal trajectory of the ventilation control system needs to be determined. The concentration of air pollutants inside the station shows a diurnal variation in accordance with the variations in the number of passengers and subway frequency. To consider the diurnal variation of IAQ, an iterative dynamic programming (IDP) that searches for a piecewise control policy by separating whole duration into several stages is used. When outdoor air is contaminated by pollutants, it enters the subway station through the ventilation system, which results in the deteriorated IAQ and adverse effects on passenger health. In this study, to consider the influence of outdoor air quality (OAQ), a new performance index of the IDP with the passenger health risk and OAQ is proposed. This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.Keywords: indoor air quality, iterative dynamic algorithm, outdoor air information, ventilation control system
Procedia PDF Downloads 50110041 On the Design of Robust Governors of Steam Power Systems Using Polynomial and State-Space Based H∞ Techniques: A Comparative Study
Authors: Rami A. Maher, Ibraheem K. Ibraheem
Abstract:
This work presents a comparison study between the state-space and polynomial methods for the design of the robust governor for load frequency control of steam turbine power systems. The robust governor is synthesized using the two approaches and the comparison is extended to include time and frequency domains performance, controller order, and uncertainty representation, weighting filters, optimality and sub-optimality. The obtained results are represented through tables and curves with reasons of similarities and dissimilarities.Keywords: robust control, load frequency control, steam turbine, H∞-norm, system uncertainty, load disturbance
Procedia PDF Downloads 40710040 Factors Influencing Infection Prevention and Control Practices in the Emergency Department of Mbarara Regional Referral Hospital in Mbarara District- Uganda
Authors: Baluku Nathan
Abstract:
Infection prevention and control (IPC) is a practical, evidence-based approach that prevents patients and emergency health workers from being harmed by avoidable infections as a result of antimicrobial resistance; all hospital infection control programs put together various practices which, when used appropriately, restrict the spread of infection. A breach in these control practices facilitates the transmission of infections from patients to health workers, other patients and attendants. It is, therefore, important for all EMTs and patients to adhere to them strictly. It is also imperative for administrators to ensure the implementation of the infection control program for their facilities. Purpose: The purpose of this study was to investigate the influencing factors of prevention practices against Infection exposure among emergency medical technicians (EMTs) in the emergency department at Mbarara hospital. Methodology: This was a descriptive cross-sectional study that employed a self-reported questionnaire that was filled out by 32 EMTs in the emergency department from 12th February to 3rd march 2022. The questionnaire consisted of items concerning the defensive environment and other Factors influencing Infection prevention and control practices in the accident and emergency department of Mbarara hospital. Results: From the findings, majority16(50%) always used protective gear when doing clinical work,14 (43.8%) didn’t use protective gear, citing they were only assisting those performing resuscitations, gumboots were the least used protective gear with only3(9.4%) usage. Regarding disposal techniques of specific products like blood and sharps, results showed 10 (31.3%) said blood is disposed of in red buckets, 5(15.6%) in yellow buckets and only5(15.6%) in black buckets and 12(37.5%) didn’t respond. However, 28(87.5%) said sharps were disposed of in a sharps container. The majority, 17(53.1%), were not aware of the infection control guidelines even though they were pinned on walls of the emergency rooms,15(46.9%) said they had never had quality assurance monitoring events,14(43.8%) said monitoring was continuous while15(46.9 %) said it was discrete. Conclusions: The infection control practices at the emergency department were inadequate in view of less than 100% of the EMTs observing the five principles of infection prevention, such as the use of personal protective equipment and proper waste disposal in appropriate color-coded bins. Dysfunctional infection prevention and control committees accompanied by inadequate supervision to ensure infection control remained a big challenge.Keywords: infection prevention, influencing factors, emergency medical technician (EMT), emergency unit
Procedia PDF Downloads 11310039 The Design of PFM Mode DC-DC Converter with DT-CMOS Switch
Authors: Jae-Chang Kwak, Yong-Seo Koo
Abstract:
The high efficiency power management IC (PMIC) with switching device is presented in this paper. PMIC is controlled with PFM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS (DT-CMOS) with low on-resistance is designed to decrease conduction loss. The threshold voltage of DT-CMOS drops as the gate voltage increase, resulting in a much higher current handling capability than standard MOSFET. PFM control circuits consist of a generator, AND gate and comparator. The generator is made to have 1.2MHz oscillation voltage. The DC-DC converter based on PFM control circuit and low on-resistance switching device is presented in this paper.Keywords: DT-CMOS, PMIC, PFM, DC-DC converter
Procedia PDF Downloads 45110038 Artificial Neural Network Speed Controller for Excited DC Motor
Authors: Elabed Saud
Abstract:
This paper introduces the new ability of Artificial Neural Networks (ANNs) in estimating speed and controlling the separately excited DC motor. The neural control scheme consists of two parts. One is the neural estimator which is used to estimate the motor speed. The other is the neural controller which is used to generate a control signal for a converter. These two neutrals are training by Levenberg-Marquardt back-propagation algorithm. ANNs are the standard three layers feed-forward neural network with sigmoid activation functions in the input and hidden layers and purelin in the output layer. Simulation results are presented to demonstrate the effectiveness of this neural and advantage of the control system DC motor with ANNs in comparison with the conventional scheme without ANNs.Keywords: Artificial Neural Network (ANNs), excited DC motor, convenional controller, speed Controller
Procedia PDF Downloads 72610037 Optimization of Stevia Concentration in Rasgulla (Sweet Syrup Cheese Ball) Based on Quality
Authors: Gurveer Kaur, T. K. Goswami
Abstract:
Rasgulla (a sweet syrup cheese ball), a sweet, spongy dessert represents traditional sweet dish of an Indian subcontinent prepared by chhana. 100 g of Rasgulla contains 186 calories, and so it is a driving force behind obesity and diabetes. To reduce Rasgulla’s energy value sucrose mainly should be minimized, so instead of sucrose, stevia (zero calories natural sweetener) is used to prepare Rasgulla. In this study three samples were prepared with sucrose to stevia ratio taking 100:0 (as control sample), (i) 50:50 (T1); (ii) 25:75 (T2), and (iii) 0:100 (T3) from 4% fat milk. It was found that as the sucrose concentration decreases the percentage of fat increase in the Rasgulla slightly. Sample T2 showed < 0.1% (±0.06) sucrose content. But there was no significant difference on protein and ash content of the samples. Whitening index was highest (78.0 ± 0.13) for T2 and lowest (65.7 ± 0.21) for the control sample since less sucrose in syrup reduces the browning of the sample (T2). Energy value per 100 g was calculated to be 50, 72, 98, and 184 calories for T3, T2, T1 and control samples, respectively. According to optimization study, the preferred (high quality) order of samples was as follows: T1 > T1 > control > T3. Low sugar content Rasgulla with acceptable quality can be prepared with 25:75 ratio of sucrose to stevia.Keywords: composition, rasgulla, sensory, stevia
Procedia PDF Downloads 206