Search results for: combined immunotherapy and radiation
3721 Effect of Thermal Radiation and Chemical Reaction on MHD Flow of Blood in Stretching Permeable Vessel
Authors: Binyam Teferi
Abstract:
In this paper, a theoretical analysis of blood flow in the presence of thermal radiation and chemical reaction under the influence of time dependent magnetic field intensity has been studied. The unsteady non linear partial differential equations of blood flow considers time dependent stretching velocity, the energy equation also accounts time dependent temperature of vessel wall, and concentration equation includes time dependent blood concentration. The governing non linear partial differential equations of motion, energy, and concentration are converted into ordinary differential equations using similarity transformations solved numerically by applying ode45. MATLAB code is used to analyze theoretical facts. The effect of physical parameters viz., permeability parameter, unsteadiness parameter, Prandtl number, Hartmann number, thermal radiation parameter, chemical reaction parameter, and Schmidt number on flow variables viz., velocity of blood flow in the vessel, temperature and concentration of blood has been analyzed and discussed graphically. From the simulation study, the following important results are obtained: velocity of blood flow increases with both increment of permeability and unsteadiness parameter. Temperature of the blood increases in vessel wall as Prandtl number and Hartmann number increases. Concentration of the blood decreases as time dependent chemical reaction parameter and Schmidt number increases.Keywords: stretching velocity, similarity transformations, time dependent magnetic field intensity, thermal radiation, chemical reaction
Procedia PDF Downloads 913720 A Compact Wearable Slot Antenna for LTE and WLAN Applications
Authors: Haider K. Raad
Abstract:
In this paper, a compact wide-band, ultra-thin and flexible slot antenna intended for wearable applications is presented. The presented antenna is designed to provide Wireless Local Area Network (WLAN) and Long Term Evolution (LTE) connectivity. The presented design exhibits a relatively wide bandwidth (1600-3500 MHz below -6 dB impedance bandwidth limit). The antenna is positioned on a 33 mm x 30 mm flexible substrate with a thickness of 50 µm. Antenna properties, such as the far-field radiation patterns, scattering parameter S11 are provided. The presented compact, thin and flexible design along with excellent radiation characteristics are deemed suitable for integration into flexible and wearable devices.Keywords: wearable electronics, slot Antenna, LTE, WLAN
Procedia PDF Downloads 2343719 Researches Concerning Photons as Corpuscles with Mass and Negative Electrostatic Charge
Authors: Ioan Rusu
Abstract:
Let us consider that the entire universe is composed of a single hydrogen atom within which the electron is moving around the proton. In this case, according to classical theories of physics, radiation and photons, respectively, should be absorbed by the electron. Depending on the number of photons absorbed, the electron radius of rotation around the proton is established. Until now, the principle of photon absorption by electrons and the electron transition to a new energy level, namely to a higher radius of rotation around the proton, is not clarified in physics. This paper aims to demonstrate that photons have mass and negative electrostatic charge similar to electrons but infinitely smaller. The experiments which demonstrate this theory are simple: thermal expansion, photoelectric effect and thermonuclear reaction.Keywords: electrostatic, electron, photon, proton, radiation
Procedia PDF Downloads 3963718 Protective Role of Curcumin against Ionising Radiation of Gamma Ray
Authors: Turban Kar, Maitree Bhattacharyya
Abstract:
Curcumin, a dietary antioxidant has been identified as a wonder molecule to possess therapeutic properties protecting the cellular macromolecules from oxidative damage. In our experimental study, we have explored the effectiveness of curcumin in protecting the structural paradigm of Human Serum Albumin (HSA) when exposed to gamma irradiation. HSA, being an important transport protein of the circulatory system, is involved in binding of variety of metabolites, drugs, dyes and fatty acids due to the presence of hydrophobic pockets inside the structure. HSA is also actively involved in the transportation of drugs and metabolites to their targets, because of its long half-life and regulation of osmotic blood pressure. Gamma rays, in its increasing concentration, results in structural alteration of the protein and superoxide radical generation. Curcumin, on the other hand, mitigates the damage, which has been evidenced in the following experiments. Our study explores the possibility for protection by curcumin during the molecular and conformational changes of HSA when exposed to gamma irradiation. We used a combination of spectroscopic methods to probe the conformational ensemble of the irradiated HSA and finally evaluated the extent of restoration by curcumin. SDS - PAGE indicated the formation of cross linked aggregates as a consequence of increasing exposure of gamma radiation. CD and FTIR spectroscopy inferred significant decrease in alpha helix content of HSA from 57% to 15% with increasing radiation doses. Steady state and time resolved fluorescence studies complemented the spectroscopic measurements when lifetime decay was significantly reduced from 6.35 ns to 0.37 ns. Hydrophobic and bityrosine study showed the effectiveness of curcumin for protection against radiation induced free radical generation. Moreover, bityrosine and hydrophobic profiling of gamma irradiated HSA in presence and absence of curcumin provided light on the formation of ROS species generation and the protective (magical) role of curcumin. The molecular mechanism of curcumin protection to HSA from gamma irradiation is yet unknown, though a possible explanation has been proposed in this work using Thioflavin T assay. It was elucidated, that when HSA is irradiated at low dose of gamma radiation in presence of curcumin, it is capable of retaining the native characteristic properties to a greater extent indicating stabilization of molecular structure. Thus, curcumin may be utilized as a therapeutic strategy to protect cellular proteins.Keywords: Bityrosine content, conformational change, curcumin, gamma radiation, human serum albumin
Procedia PDF Downloads 1563717 An Improved Model of Estimation Global Solar Irradiation from in situ Data: Case of Oran Algeria Region
Authors: Houcine Naim, Abdelatif Hassini, Noureddine Benabadji, Alex Van Den Bossche
Abstract:
In this paper, two models to estimate the overall monthly average daily radiation on a horizontal surface were applied to the site of Oran (35.38 ° N, 0.37 °W). We present a comparison between the first one is a regression equation of the Angstrom type and the second model is developed by the present authors some modifications were suggested using as input parameters: the astronomical parameters as (latitude, longitude, and altitude) and meteorological parameters as (relative humidity). The comparisons are made using the mean bias error (MBE), root mean square error (RMSE), mean percentage error (MPE), and mean absolute bias error (MABE). This comparison shows that the second model is closer to the experimental values that the model of Angstrom.Keywords: meteorology, global radiation, Angstrom model, Oran
Procedia PDF Downloads 2333716 Prevalence of Menopausal Women with Clinical Symptoms of Allergy and Evaluation the Effect of Sex Hormone Combined with Anti-Allergy Treatment
Authors: Yang Wei, Xueyan Wang, Hui Zou
Abstract:
Objective: Investigation the prevalence of menopausal symptoms in patients with allergic symptoms, evaluation of the effect of sex hormones combined with anti-allergic therapy in these patients. Method: Age of 45-65 years old women with allergic symptoms at the same time in gynecological-endocrinology clinic in our hospital were selected from Feb 1 to May 31, 2010, randomly. The patients were given oral estradiol valerate plus progestin pills combined with anti-allergy treatment and then evaluated twice a week and one month later. Evaluation criterion: Menopause Rating Scale (MRS) and the degree of clinical symptoms were used to evaluate menopause and allergy separately. Results: 1) There were 195 cases of patients with menopausal symptoms at the age. Their MRS were all over 15. 2) Among them 45 patients were with allergic symptom accounted for 23% which were diagnosed by allergic department. 3) Evaluated after one week: the menopausal symptoms were improved and MRS were less than or equal to 5 in all these patients; the skin symptom of allergic symptoms vanished completely. 4) Evaluated after one month: Menopause symptoms were improved steadily; other clinical symptoms of allergy were also improved or without recurrence. Conclusion: The incidence rate of menopausal women with clinical symptoms of allergic diseases is high and it needs attention. The effect of sex hormones combined with anti-allergic therapy is obvious.Keywords: menopausal, allergy, sex hormone, anti-allergy treatment
Procedia PDF Downloads 2723715 Simulation of Wind Solar Hybrid Power Generation for Pumping Station
Authors: Masoud Taghavi, Gholamreza Salehi, Ali Lohrasbi Nichkoohi
Abstract:
Despite the growing use of renewable energies in different fields of application of this technology in the field of water supply has been less attention. Photovoltaic and wind hybrid system is that new topics in renewable energy, including photovoltaic arrays, wind turbines, a set of batteries as a storage system and a diesel generator as a backup system is. In this investigation, first climate data including average wind speed and solar radiation at any time during the year, data collection and analysis are performed in the energy. The wind turbines in four models, photovoltaic panels at the 6 position of relative power, batteries and diesel generator capacity in seven states in the two models are combined hours of operation with renewables, diesel generator and battery bank check and a hybrid system of solar power generation-wind, which is optimized conditions, are presented.Keywords: renewable energy, wind and solar energy, hybrid systems, cloning station
Procedia PDF Downloads 3993714 Study on the Fabrication and Mechanical Characterization of Pineapple Fiber-Reinforced Unsaturated Polyester Resin Based Composites: Effect of Gamma Irradiation
Authors: Kamrun N. Keya, Nasrin A. Kona, Ruhul A. Khan
Abstract:
Pineapple leaf fiber (PALF) reinforced polypropylene (PP) based composites were fabricated by a conventional compression molding technique. In this investigation, PALF composites were manufactured using different percentages of fiber, which were varying from 25-50% on the total weight of the composites. To fabricate the PALF/PP composites, untreated and treated fibers were selected. A systematic study was done to observe the physical, mechanical and interfacial behavior of the composites. In this study, mechanical properties of the composites such as tensile, impact and bending properties were observed precisely. It was found that 45wt% of fiber composites showed better mechanical properties than others. Maximum tensile strength (TS) and bending strength (BS) was observed, 65 MPa and 50 MPa respectively, whereas the highest tensile modulus (TM) and bending modulus (BM) was examined, 1.7 GPa and 0.85 GPa respectively. The PALF/PP based composites were treated with irradiated under gamma radiation (the source strength 50 kCi Cobalt-60) of various doses (2.5 kGy to 10 kGy). The effect of gamma radiation on the composites was also investigated, and it found that the effect of 5.0 kGy (i.e. units for radiation measurement is 'gray', kGy=kilogray ) gamma dose showed better mechanical properties than other doses. The values of TS, BS, TM, and BM of the irradiated (5.0 kGy) composites were found to improve by 19%, 23%, 17% and 25 % over non-irradiated composites. After flexural testing, fracture sides of the untreated and treated both composites were studied by scanning electron microscope (SEM). SEM results of the treated PALF/PP based composites showed better fiber-matrix adhesion and interfacial bonding than untreated PALF/PP based composites. Water uptake and soil degradation tests of untreated and treated composites were also investigated.Keywords: PALF, polypropylene, compression molding technique, gamma radiation, mechanical properties, scanning electron microscope
Procedia PDF Downloads 1513713 UV-Cured Coatings Based on Acrylated Epoxidized Soybean Oil and Epoxy Carboxylate
Authors: Alaaddin Cerit, Suheyla Kocaman, Ulku Soydal
Abstract:
During the past two decades, photoinitiated polymerization has been attracting a great interest in terms of scientific and industrial activity. The wide recognition of UV treatment in the polymer industry results not only from its many practical applications but also from its advantage for low-cost processes. Unlike most thermal curing systems, radiation-curable systems can polymerize at room temperature without additional heat, and the curing is completed in a very short time. The advantage of cationic UV technology is that post-cure can continue in the ‘dark’ after radiation. In this study, bio-based acrylated epoxidized soybean oil (AESO) was cured with UV radiation using radicalic photoinitiator Irgacure 184. Triarylsulphonium hexafluoroantimonate was used as cationic photoinitiator for curing of 3,4-epoxycyclohexylmethyl-3,4-epoxycyclohexanecarboxylate. The effect of curing time and the amount of initiators on the curing degree and thermal properties were investigated. The thermal properties of the coating were analyzed after crosslinking UV irradiation. The level of crosslinking in the coating was evaluated by FTIR analysis. Cationic UV-cured coatings demonstrated excellent adhesion and corrosion resistance properties. Therefore, our study holds a great potential with its simple and low-cost applications.Keywords: acrylated epoxidized soybean oil, epoxy carboxylate, thermal properties, uv-curing
Procedia PDF Downloads 2593712 Comparison of Breast Surface Doses for Full-Field Digital Mammography and Digital Breast Tomosynthesis Using Breast Phantoms
Authors: Chia-Hui Chen, Chien-Kuo Wang
Abstract:
Background: Full field digital mammography (FFDM) is widely used in diagnosis of breast cancer. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Hence, the radiation dose delivered to the patients involved in an imaging protocol is of utmost concern. Aim: To compare the surface radiation dose (ESD) of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) by using breast phantoms. Method: We analyzed the average entrance surface dose (ESD) of FFDM and DBT by using breast phantoms. Optically Stimulated luminescent Dosimeters (OSLD) were placed in a tissue-equivalent Breast phantom at difference sites of interest. Absorbed dose measurements were obtained after digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) exposures. Results: An automatic exposure control (AEC) is proposed for surface dose measurement during DBT and FFDM. The mean ESD values for DBT and FFDM were 6.37 mGy and 3.51mGy, respectively. Using of OSLD measured for surface dose during DBT and FFDM. There were 19.87 mGy and 11.36 mGy, respectively. The surface exposure dose of DBT could possibly be increased by two times with FFDM. Conclusion: The radiation dose from DBT was higher than that of FFDM and the difference in dose between AEC and OSLD measurements at phantom surface.Keywords: full-field digital mammography, digital breast tomosynthesis, optically stimulated luminescent dosimeters, surface dose
Procedia PDF Downloads 4203711 Study of Natural Radioactive and Radiation Hazard Index of Soil from Sembrong Catchment Area, Johor, Malaysia
Authors: M. I. A. Adziz, J. Sharib Sarip, M. T. Ishak, D. N. A. Tugi
Abstract:
Radiation exposure to humans and the environment is caused by natural radioactive material sources. Given that exposure to people and communities can occur through several pathways, it is necessary to pay attention to the increase in naturally radioactive material, particularly in the soil. Continuous research and monitoring on the distribution and determination of these natural radionuclides' activity as a guide and reference are beneficial, especially in an accidental exposure. Surface soil/sediment samples from several locations identified around the Sembrong catchment area were taken for the study. After 30 days of secular equilibrium with their daughters, the activity concentrations of the naturally occurring radioactive material (NORM) members, i.e. ²²⁶Ra, ²²⁸Ra, ²³⁸U, ²³²Th, and ⁴⁰K, were measured using high purity germanium (HPGe) gamma spectrometer. The results obtained showed that the radioactivity concentration of ²³⁸U ranged between 17.13 - 30.13 Bq/kg, ²³²Th ranged between 22.90 - 40.05 Bq/kg, ²²⁶Ra ranged between 19.19 - 32.10 Bq/kg, ²²⁸Ra ranged between 21.08 - 39.11 Bq/kg and ⁴⁰K ranged between 9.22 - 51.07 Bq/kg with average values of 20.98 Bq/kg, 27.39 Bq/kg, 23.55 Bq/kg, 26.93 Bq/kg and 23.55 Bq/kg respectively. The values obtained from this study were low or equivalent to previously reported in previous studies. It was also found that the mean/mean values obtained for the four parameters of the Radiation Hazard Index, namely radium equivalent activity (Raeq), external dose rate (D), annual effective dose and external hazard index (Hₑₓ), were 65.40 Bq/kg, 29.33 nGy/h, 19.18 ¹⁰⁻⁶Sv and 0.19 respectively. These obtained values are low compared to the world average values and the values of globally applied standards. Comparison with previous studies (dry season) also found that the values for all four parameters were low and equivalent. This indicates the level of radiation hazard in the area around the study is safe for the public.Keywords: catchment area, gamma spectrometry, naturally occurring radioactive material (NORM), soil
Procedia PDF Downloads 1013710 Optimization of a Combined Ejector-Vapor Compression Refrigeration Systems with R134a
Authors: Ilhem Ouelhazi, Mouna Elakhdar, Lakdar Kairouani
Abstract:
A computer simulation model for a combined ejector-vapor compression cycle that uses working fluid R134a. A refrigeration system was developed which combines a basic vapor compression refrigeration cycle with an ejector cooling cycle. A one-dimensional mathematical model was developed using the equations governing the flow and thermodynamics based on the constant area ejector flow model. The effects of the operating parameters on the cooling capacity, the performance coefficient, and the entrainment ratio are studied. The current model is based on the NIST-REFPROP database for refrigerants properties calculations. The simulated performance is compared with the available experimental data from the literature for validation.Keywords: combined refrigeration cycle, constant area ejector, R134a, ejector-cooling cycle, performance, mathematical simulation, vapor compression cycle
Procedia PDF Downloads 2263709 Organ Dose Calculator for Fetus Undergoing Computed Tomography
Authors: Choonsik Lee, Les Folio
Abstract:
Pregnant patients may undergo CT in emergencies unrelated with pregnancy, and potential risk to the developing fetus is of concern. It is critical to accurately estimate fetal organ doses in CT scans. We developed a fetal organ dose calculation tool using pregnancy-specific computational phantoms combined with Monte Carlo radiation transport techniques. We adopted a series of pregnancy computational phantoms developed at the University of Florida at the gestational ages of 8, 10, 15, 20, 25, 30, 35, and 38 weeks (Maynard et al. 2011). More than 30 organs and tissues and 20 skeletal sites are defined in each fetus model. We calculated fetal organ dose-normalized by CTDIvol to derive organ dose conversion coefficients (mGy/mGy) for the eight fetuses for consequential slice locations ranging from the top to the bottom of the pregnancy phantoms with 1 cm slice thickness. Organ dose from helical scans was approximated by the summation of doses from multiple axial slices included in the given scan range of interest. We then compared dose conversion coefficients for major fetal organs in the abdominal-pelvis CT scan of pregnancy phantoms with the uterine dose of a non-pregnant adult female computational phantom. A comprehensive library of organ conversion coefficients was established for the eight developing fetuses undergoing CT. They were implemented into an in-house graphical user interface-based computer program for convenient estimation of fetal organ doses by inputting CT technical parameters as well as the age of the fetus. We found that the esophagus received the least dose, whereas the kidneys received the greatest dose in all fetuses in AP scans of the pregnancy phantoms. We also found that when the uterine dose of a non-pregnant adult female phantom is used as a surrogate for fetal organ doses, root-mean-square-error ranged from 0.08 mGy (8 weeks) to 0.38 mGy (38 weeks). The uterine dose was up to 1.7-fold greater than the esophagus dose of the 38-week fetus model. The calculation tool should be useful in cases requiring fetal organ dose in emergency CT scans as well as patient dose monitoring.Keywords: computed tomography, fetal dose, pregnant women, radiation dose
Procedia PDF Downloads 1403708 General Formula for Water Surface Profile over Side Weir in the Combined, Trapezoidal and Exponential, Channels
Authors: Abdulrahman Abdulrahman
Abstract:
A side weir is a hydraulic structure set into the side of a channel. This structure is used for water level control in channels, to divert flow from a main channel into a side channel when the water level in the main channel exceeds a specific limit and as storm overflows from urban sewerage system. Computation of water surface over the side weirs is essential to determine the flow rate of the side weir. Analytical solutions for water surface profile along rectangular side weir are available only for the special cases of rectangular and trapezoidal channels considering constant specific energy. In this paper, a rectangular side weir located in a combined (trapezoidal with exponential) channel was considered. Expanding binominal series of integer and fraction powers and the using of reduction formula of cosine function integrals, a general analytical formula was obtained for water surface profile along a side weir in a combined (trapezoidal with exponential) channel. Since triangular, rectangular, trapezoidal and parabolic cross-sections are special cases of the combined cross section, the derived formula, is applicable to triangular, rectangular, trapezoidal cross-sections as analytical solution and semi-analytical solution to parabolic cross-section with maximum relative error smaller than 0.76%. The proposed solution should be a useful engineering tool for the evaluation and design of side weirs in open channel.Keywords: analytical solution, combined channel, exponential channel, side weirs, trapezoidal channel, water surface profile
Procedia PDF Downloads 2373707 Proton Irradiation Testing on Commercial Enhancement Mode GaN Power Transistor
Authors: L. Boyaci
Abstract:
Two basic equipment of electrical power subsystem of space satellites are Power Conditioning Unit (PCU) and Power Distribution Unit (PDU). Today, the main switching element used in power equipment in satellites is silicon (Si) based radiation-hardened MOSFET. GaNFETs have superior performances over MOSFETs in terms of their conduction and switching characteristics. GaNFET has started to take MOSFET’s place in many applications in industry especially by virtue of its switching performances. If GaNFET can also be used in equipment for space applications, this would be great revolution for future space power subsystem designs. In this study, the effect of proton irradiation on Gallium Nitride based power transistors was investigated. Four commercial enhancement mode GaN power transistors from Efficient Power Conversion Corporation (EPC) are irradiated with 30MeV protons while devices are switching. Flux of 8.2x10⁹ protons/cm²/s is applied for 12.5 seconds to reach ultimate fluence of 10¹¹ protons/cm². Vgs-Ids characteristics are measured and recorded for each device before, during and after irradiation. It was observed that if there would be destructive events. Proton induced permanent damage on devices is not observed. All the devices remained healthy and continued to operate. For two of these devices, further irradiation is applied with same flux for 30 minutes up to a total fluence level of 1.476x10¹³ protons/cm². We observed that GaNFETs are fully functional under this high level of radiation and no destructive events and irreversible failures took place for transistors. Results reveal that irradiated GaNFET in this experiment has radiation tolerance under proton testing and very important candidate for being one of the future power switching element in space.Keywords: enhancement mode GaN power transistors, proton irradiation effects, radiation tolerance
Procedia PDF Downloads 1523706 Estimation of Lungs Physiological Motion for Patient Undergoing External Lung Irradiation
Authors: Yousif Mohamed Y. Abdallah
Abstract:
This is an experimental study deals with detection, measurement and analysis of the periodic physiological organ motion during external beam radiotherapy; to improve the accuracy of the radiation field placement, and to reduce the exposure of healthy tissue during radiation treatments. The importance of this study is to detect the maximum path of the mobile structures during radiotherapy delivery, to define the planning target volume (PTV) and irradiated volume during both inspiration and expiration period and to verify the target volume. In addition to its role to highlight the importance of the application of Intense Guided Radiotherapy (IGRT) methods in the field of radiotherapy. The results showed (body contour was equally (3.17 + 0.23 mm), for left lung displacement reading (2.56 + 0.99 mm) and right lung is (2.42 + 0.77 mm) which the radiation oncologist to take suitable countermeasures in case of significant errors. In addition, the use of the image registration technique for automatic position control is predicted potential motion. The motion ranged between 2.13 mm and 12.2 mm (low and high). In conclusion, individualized assessment of tumor mobility can improve the accuracy of target areas definition in patients undergo Sterostatic RT for stage I, II and III lung cancer (NSCLC). Definition of the target volume based on a single CT scan with a margin of 10 mm is clearly inappropriate.Keywords: respiratory motion, external beam radiotherapy, image processing, lung
Procedia PDF Downloads 5353705 Prediction of Ionizing Radiation Doses in Irradiated red Pepper (Capsicum annuum) and Mint (Mentha piperita) by Gel Electrophoresis
Authors: Şeyma Özçirak Ergün, Ergün Şakalar, Emrah Yalazi̇, Nebahat Şahi̇n
Abstract:
Food irradiation is a usage of exposing food to ionising radiation (IR) such as gamma rays. IR has been used to decrease the number of harmful microorganisms in the food such as spices. Excessive usage of IR can cause damage to both food and people who consuming food. And also it causes to damages on food DNA. Generally, IR detection techniques were utilized in literature for spices are Electron Spin Resonance (ESR), Thermos Luminescence (TL). Storage creates negative effect on IR detection method then analyses of samples have been performed without storage in general. In the experimental part, red pepper (Capsicum annuum) and mint (Mentha piperita) as spices were exposed to 0, 0.272, 0.497, 1.06, 3.64, 8.82, and 17.42 kGy ionize radiation. ESR was applied to samples irradiated. DNA isolation from irradiated samples was performed using GIDAGEN Multi Fast DNA isolation kit. The DNA concentration was measured using a microplate reader spectrophotometer (Infinite® 200 PRO-Life Science–Tecan). The concentration of each DNA was adjusted to 50 ng/µL. Genomic DNA was imaged by UV transilluminator (Gel Doc XR System, Bio-Rad) for the estimation of genomic DNA bp-fragment size after IR. Thus, agarose gel profiles of irradiated spices were obtained to determine the change of band profiles. Besides, samples were examined at three different time periods (0, 3, 6 months storage) to show the feasibility of developed method. Results of gel electrophoresis showed especially degradation of DNA of irradiated samples. In conclusion, this study with gel electrophoresis can be used as a basis for the identification of the dose of irradiation by looking at degradation profiles at specific amounts of irradiation. Agarose gel results of irradiated samples were confirmed with ESR analysis. This method can be applied widely to not only food products but also all biological materials containing DNA to predict radiation-induced damage of DNA.Keywords: DNA, electrophoresis, gel electrophoresis, ionizeradiation
Procedia PDF Downloads 2593704 Protection of Patients and Staff in External Beam Radiotherapy Using Linac in Kenya
Authors: Calvince Okome Odeny
Abstract:
There is a current action to increase radiotherapy services in Kenya. The National government of Kenya, in collaboration with the county governments, has embarked on building radiotherapy centers in all 47 regions of the country. As these new centers are established in Kenya, it has to be ensured that minimum radiation safety standards are in place prior to operation. For full implementation of this, it is imperative that more Research and training for regulators are done on radiation protection, and safety and national regulatory infrastructure is geared towards ensuring radiation protection and safety in all aspects of the use of external radiotherapy practices. The present work aims at reviewing the level of protection and safety for patients and staff during external beam radiotherapy using Linac in Kenya and provides relevant guidance to improve protection and safety. A retrospective evaluation was done to verify whether those occupationally exposed workers and patients are adequately protected from the harmful effect of radiation exposure during the treatment procedures using Linac. The project was experimental Research, also including an analysis of resource documents obtained from the literature and international organizations. The critical findings of the work revealed that the key elements of protection of occupationally exposed workers and patients include a comprehensive quality Management system governing all planned activities from siting, safety, and design of the Facility, construction, acceptance testing, commissioning, operation, and decommissioning of the Facility; Government empowering the Regulatory Authority to license Medical Linear facilities and to enforce the applicable regulations to ensure adequate protection; A comprehensive Radiation Protection and Safety program must be established to ensure adequate safety and protection of workers and patients during treatment planning and treatment delivery of patients and categories of staff associated with the Facility must be well educated and trained to perform professionally with a commitment to sound safety culture. Relevant recommendations from the findings are shared with the Medical Linear Accelerator facilities and the regulatory authority to provide guidance and continuous improvement of protection and safety to improve regulatory oversight.Keywords: oncology, radiotherapy, protection, staff
Procedia PDF Downloads 753703 Analytical Formulae for the Approach Velocity Head Coefficient
Authors: Abdulrahman Abdulrahman
Abstract:
Critical depth meters, such as abroad crested weir, Venture Flume and combined control flume are standard devices for measuring flow in open channels. The discharge relation for these devices cannot be solved directly, but it needs iteration process to account for the approach velocity head. In this paper, analytical solution was developed to calculate the discharge in a combined critical depth-meter namely, a hump combined with lateral contraction in rectangular channel with subcritical approach flow including energy losses. Also analytical formulae were derived for approach velocity head coefficient for different types of critical depth meters. The solution was derived by solving a standard cubic equation considering energy loss on the base of trigonometric identity. The advantage of this technique is to avoid iteration process adopted in measuring flow by these devices. Numerical examples are chosen for demonstration of the proposed solution.Keywords: broad crested weir, combined control meter, control structures, critical flow, discharge measurement, flow control, hydraulic engineering, hydraulic structures, open channel flow
Procedia PDF Downloads 2743702 Cost-Conscious Treatment of Basal Cell Carcinoma
Authors: Palak V. Patel, Jessica Pixley, Steven R. Feldman
Abstract:
Introduction: Basal cell carcinoma (BCC) is the most common skin cancer worldwide and requires substantial resources to treat. When choosing between indicated therapies, providers consider their associated adverse effects, efficacy, cosmesis, and function preservation. The patient’s tumor burden, infiltrative risk, and risk of tumor recurrence are also considered. Treatment cost is often left out of these discussions. This can lead to financial toxicity, which describes the harm and quality of life reductions inflicted by high care costs. Methods: We studied the guidelines set forth by the American Academy of Dermatology for the treatment of BCC. A PubMed literature search was conducted to identify the costs of each recommended therapy. We discuss costs alongside treatment efficacy and side-effect profile. Results: Surgical treatment for BCC can be cost-effective if the appropriate treatment is selected for the presenting tumor. Curettage and electrodesiccation can be used in low-grade, low-recurrence tumors in aesthetically unimportant areas. The benefits of cost-conscious care are not likely to be outweighed by the risks of poor cosmesis or tumor return ($471 BCC of the cheek). When tumor burden is limited, MMS offers better cure rates and lower recurrence rates than surgical excision, and with comparable costs (MMS $1263; SE $949). Surgical excision with permanent sections may be indicated when tumor burden is more extensive or if molecular testing is necessary. The utility of surgical excision with frozen sections, which costs substantially more than MMS without comparable outcomes, is less clear (SE with frozen sections $2334-$3085). Less data exists on non-surgical treatments for BCC. These techniques cost less, but recurrence-risk is high. Side-effects of nonsurgical treatment are limited to local skin reactions, and cosmesis is good. Cryotherapy, 5-FU, and MAL-PDT are all more affordable than surgery, but high recurrence rates increase risk of secondary financial and psychosocial burden (recurrence rates 21-39%; cost $100-270). Radiation therapy offers better clearance rates than other nonsurgical treatments but is associated with similar recurrence rates and a significantly larger financial burden ($2591-$3460 BCC of the cheek). Treatments for advanced or metastatic BCC are extremely costly, but few patients require their use, and the societal cost burden remains low. Vismodegib and sonidegib have good response rates but substantial side effects, and therapy should be combined with multidisciplinary care and palliative measures. Expert-review has found sonidegib to be the less expensive and more efficacious option (vismodegib $128,358; sonidegib $122,579). Platinum therapy, while not FDA-approved, is also effective but expensive (~91,435). Immunotherapy offers a new line of treatment in patients intolerant of hedgehog inhibitors ($683,061). Conclusion: Dermatologists working within resource-compressed practices and with resource-limited patients must prudently manage the healthcare dollar. Surgical therapies for BCC offer the lowest risk of recurrence at the most reasonable cost. Non-surgical therapies are more affordable, but high recurrence rates increase the risk of secondary financial and psychosocial burdens. Treatments for advanced BCC are incredibly costly, but the low incidence means the overall cost to the system is low.Keywords: nonmelanoma skin cancer, basal cell skin cancer, squamous cell skin cancer, cost of care
Procedia PDF Downloads 1243701 The Effect of Hesperidin on Troponin's Serum Level Changes as a Heart Tissue Damage Biomarker Due to Gamma Irradiation of Rat's Mediastinum
Authors: G. H. Haddadi, S. Sajadi, R. Fardid, Z. Haddadi
Abstract:
The heart is a radiosensitive organ, and its damage is a dose-limiting factor in radiotherapy. Different side effects including vascular plaque and heart fibrosis occur in patients with thorax irradiation. The present study aimed to evaluate the radioprotective efficacy of Hesperidin (HES), a naturally occurring citrus flavanoglycone, against γ-radiation induced tissue damage in the heart of male rats. Sixty-eight rats were divided into four groups. The rats in group 1 received PBS, and those in group 2 received HES. Also, the rats in group 3 received PBS and underwent γ-irradiation, and those in group 4 received HES and underwent γ-irradiation. They were exposed to 20 Gy γ-radiation using a single fraction cobalt-60 unit, and the dose of Hesperidin was (100 mg/kg/d, orally) for 7 days prior irradiation. Each group was divided into two subgroups. Samplings of rats in subgroup A was done 4-6 hours after irradiation. The samples were sent to laboratory for determination of Troponin’s I (TnI) serum level changes as a cardiac biomarker. The remaining animals (subgroups B) were sacrificed 8 weeks after radiotherapy for histopathological evaluation. In group 3, TnI obviously increased in comparison with group 1 (p < 0.05). The comparison of groups 1 and 4 showed no significant difference. Evaluation of histopathological parameters in subgroup B showed significant differences between groups 1 and 3 in some of the cases. Inflammation (p=0.008), pericardial effusion (p=0.001) and vascular plaque (p=0.001) increased in the rats exposed to 20 Gy γ-irradiation. Using oral administration of HES significantly decreased all the above factors when compared to group 4 (P > 0.016). Administration of 100 mg/kg/day Hesperidin for 7 days resulted in decreased Troponin I and radiation heart injury. This agent may have protective effects against radiation-induced heart damage.Keywords: hesperidin, radioprotector, troponin I, cardiac inflammation, vascular plaque
Procedia PDF Downloads 2543700 Performance Evaluation of Thermosiphon Based Solar Water Heater in India
Authors: Dnyandip K. Bhamare, Manish K Rathod, Jyotirmay Banerjee
Abstract:
This paper aims to study performance of a thermosiphon solar water heating system with the help of the proposed analytical model. This proposed model predicts the temperature and mass flow rate in a thermosiphon solar water heating system depending on radiation intensity and ambient temperature. The performance of the thermosiphon solar water heating system is evaluated in the Indian context. For this, eight cities in India are selected considering radiation intensity and geographical positions. Predicted performance at various cities reveals the potential for thermosiphon solar water in India.Keywords: solar water heater, collector outlet temperature, thermosyphon, India
Procedia PDF Downloads 2593699 Combined Machine That Fertilizes Evenly under Plowing on Slopes and Planning an Experiment
Authors: Qurbanov Huseyn Nuraddin
Abstract:
The results of scientific research on a machine that pours an equal amount of mineral fertilizer under the soil to increase the productivity of grain in mountain farming and obtain quality grain are substantiated. The average yield of the crop depends on the nature of the distribution of fertilizers in the soil. Therefore, the study of effective energy-saving methods for the application of mineral fertilizers is the actual task of modern agriculture. Depending on the type and variety of plants in mountain farming, there is an optimal norm of mineral fertilizers. Applying an equal amount of fertilizer to the soil is one of the conditions that increase the efficiency of the field. One of the main agro-technical indicators of the work of mineral fertilizing machines is to ensure equal distribution of mineral fertilizers in the field. Taking into account the above-mentioned issues, a combined plough has been improved in our laboratory.Keywords: combined plough, mineral fertilizers, sprinkle fluently, fertilizer rate, cereals
Procedia PDF Downloads 733698 Effects of Lung Protection Ventilation Strategies on Postoperative Pulmonary Complications After Noncardiac Surgery: A Network Meta-Analysis of Randomized Controlled Trials
Abstract:
Background: Mechanical ventilation has been confirmed to increase the incidence of postoperative pulmonary complications (PPCs), and several studies have shown that low tidal volumes combined with positive end-expiratory pressure (PEEP) and recruitment manoeuvres (RM) reduce the incidence of PPCs. However, the optimal lung-protective ventilatory strategy remains unclear. Methods: Multiple databases were searched for randomized controlled trials (RCTs) published prior to October 2023. The association between individual PEEP (iPEEP) or other forms of lung-protective ventilation and the incidence of PPCs was evaluated by Bayesian network meta-analysis. Results: We included 58 studies (11610 patients) in this meta-analysis. The network meta-analysis showed that low ventilation (LVt) combined with iPEEP and RM was associated with significantly lower incidences of PPCs [HVt: OR=0.38 95CrI (0.19, 0.75), LVt: OR=0.33, 95% CrI (0.12, 0.82)], postoperative atelectasis, and pneumonia than was HVt or LVt. In abdominal surgery, LVT combined with iPEEP or medium-to-high PEEP and RM were associated with significantly lower incidences of PPCs, postoperative atelectasis, and pneumonia. LVt combined with iPEEP and RM was ranked the highest, which was based on SUCRA scores. Conclusion: LVt combined with iPEEP and RM decreased the incidences of PPCs, postoperative atelectasis, and pneumonia in noncardiac surgery patients. iPEEP-guided ventilation was the optimal lung protection ventilation strategy. The quality of evidence was moderate.Keywords: protection ventilation strategies, postoperative pulmonary complications, network meta-analysis, noncardiac surgery
Procedia PDF Downloads 353697 Nondestructive Acoustic Microcharacterisation of Gamma Irradiation Effects on Sodium Oxide Borate Glass X2Na2O-X2B2O3 by Acoustic Signature
Authors: Ibrahim Al-Suraihy, Abdellaziz Doghmane, Zahia Hadjoub
Abstract:
We discuss in this work the elastic properties by using acoustic microscopes to measure Rayleigh and longitudinal wave velocities in a no radiated and radiated sodium borate glasses X2Na2O-X2B2O3 with 0 ≤ x ≤ 27 (mol %) at microscopic resolution. The acoustic material signatures were first measured, from which the characteristic surface velocities were determined.Longitudinal and shear ultrasonic velocities were measured in a different composition of sodium borate glass samples before and after irradiation with γ-rays. Results showed that the effect due to increasing sodium oxide content on the ultrasonic velocity appeared more clearly than due to γ-radiation. It was found that as Na2O composition increases, longitudinal velocities vary from 3832 to 5636 m/s in irradiated sample and it vary from 4010 to 5836 m/s in high radiated sample by 10 dose whereas shear velocities vary from 2223 to 3269 m/s in irradiated sample and it vary from 2326 m/s in low radiation to 3385 m/s in high radiated sample by 10 dose. The effect of increasing sodium oxide content on ultrasonic velocity was very clear. The increase of velocity was attributed to the gradual increase in the rigidity of glass and hence strengthening of network due to gradual change of boron atoms from the three-fold to the four-fold coordination of oxygen atoms. The ultrasonic velocities data of glass samples have been used to find the elastic modulus. It was found that ultrasonic velocity, elastic modulus and microhardness increase with increasing barium oxide content and increasing γ-radiation dose.Keywords: mechanical properties X2Na2O-X2B2O3, acoustic signature, SAW velocities, additives, gamma-radiation dose
Procedia PDF Downloads 3963696 Treatment of Cutting Oily-Wastewater by Sono-Fenton Process: Experimental Approach and Combined Process
Authors: Pisut Painmanakul, Thawatchai Chintateerachai, Supanid Lertlapwasin, Nusara Rojvilavan, Tanun Chalermsinsuwan, Nattawin Chawaloesphonsiya, Onanong Larpparisudthi
Abstract:
Conventional coagulation, advance oxidation process (AOPs), and the combined process were evaluated and compared for its suitability to treat the stabilized cutting-oil wastewater. The 90% efficiency was obtained from the coagulation at Al2(SO4)3 dosage of 150 mg/L and pH 7. On the other hands, efficiencies of AOPs for 30 minutes oxidation time were 10% for acoustic oxidation, 12% for acoustic oxidation with hydrogen peroxide, 76% for Fenton, and 92% sono-Fenton processes. The highest efficiency for effective oil removal of AOPs required large amount of chemical. Therefore, AOPs were studied as a post-treatment after conventional separation process. The efficiency was considerable as the effluent COD can pass the standard required for industrial wastewater discharge with less chemical and energy consumption.Keywords: cutting oily-wastewater, advance oxidation process, sono-fenton, combined process
Procedia PDF Downloads 3553695 Use of GIS and Remote Sensing for Calculating the Installable Photovoltaic and Thermal Power on All the Roofs of the City of Aix-en-Provence, France
Authors: Sofiane Bourchak, Sébastien Bridier
Abstract:
The objective of this study is to show how to calculate and map solar energy’s quantity (instantaneous and accumulated global solar radiation during the year) available on roofs in the city Aix-en-Provence which has a population of 140,000 inhabitants. The result is a geographic information system (GIS) layer, which represents hourly and monthly the production of solar energy on roofs throughout the year. Solar energy professionals can use it to optimize implementations and to size energy production systems. The results are presented as a set of maps, tables and histograms in order to determine the most effective costs in Aix-en-Provence in terms of photovoltaic power (electricity) and thermal power (hot water).Keywords: geographic information system, photovoltaic, thermal, solar potential, solar radiation
Procedia PDF Downloads 4363694 Power and Efficiency of Photovoltaic Module: Effect of Cell Temperature
Authors: R. Nasrin, M. Ferdows
Abstract:
Among the renewable energy sources, photovoltaic (PV) is a high potential, effective, and sustainable system. Irradiation intensity from 200 W/m2 to 1000 W/m2 has been considered to observe the performance of PV module. Generally, this module converts only about 15% - 20% of incident irradiation into electrical energy and the rest part is converted into heat energy. Finite element method has been used to solve the problem numerically. Simulation has been performed by considering the ambient temperature 30°C. Higher irradiation increase solar cell temperature and electrical power. The electrical efficiency of PV module decreases with the variation of solar radiation. The efficiency of PV module can be increased if cell temperature is reduced. Thus the effect of irradiation is significant to enhance the efficiency of PV module if the solar cell temperature is kept at a certain level.Keywords: PV module, solar radiation, efficiency, cell temperature
Procedia PDF Downloads 3613693 Effect of Ethanolic Extract of Keladi Tikus (Typhonium flagelliforme) on the Level of Ifn Γ (Interferon Gamma), Vascular Endothelial Growth Factor (VEGF) and Caspase 3 Expression
Authors: Chodidjah, Edi Dharmana, Hardhono, Sarjadi
Abstract:
Breast cancer treatment options including surgery, radiation therapy, chemotherapy, and immunotherapy have not been effective. Besides, they have side effects. Keladi Tikus (Typhonium flagelliforme) has been shown to improve immune system, suppress tumor growth and induce apoptosis. One of the parameters for immune system, tumor growth and apoptosis is IFNγ (Interferon γ), VEGF (Vascular Endothelial Growth Factor) and Caspase 3 respectively. The aim of this study was to examine the effect of the administration of Keladi Tikus tuber extract at the dose of 200 mg/kgBW, 400 mg/KgBW, and 800 mg/kgBW on the level of IFNγ, VEGF and caspase 3 expression. In this experimental study using post test randomized control group design, 24 CH3 mice with tumor were randomly divided into 4 groups including control group and treated groups: Treated with 0.2 cc extract of Keladi Tikus at the dose of 200 mg/kgBW, 400 mg/kgBW, 800 mg/kgBW, respectively for 30 days. On day 31 the lymphatic tissue was taken and evaluated for its level of IFNγ, using ELISA. The tumor tissue was taken and subjected to immunohistochemistry staining for VEGF and caspase 3 expression evaluation. The data on IFNγ, VEGF and Caspase 3 expression were analyzed using One Way Anova with significant level of 0.05. One Way Anova resulted in p<0.05. LSD test showed that the level of IFNγ and Caspase 3 for control group was different from that of treated groups. There was no significant different between the treated group of 400 mg/KgBW and 800mg/KgBW. VEGF expressions for all the treated groups were significant. In conclusion, the oral administration of ethanolic extract of Keladi Tikus (Typhonium flagelliforme) at the dose of 200mg/kgBW, 400 mg/kgBW,800 mg/kgBW increases IFNγ, Caspase 3 and decreases VEGF expression in C3H mice with adenocarsinoma mamma.Keywords: Typhonium flagelliforme, IFNγ, caspase 3, VEGF
Procedia PDF Downloads 4263692 Quality Control Assessment of X-Ray Equipment in Hospitals of Katsina State, Nigeria
Authors: Aminu Yakubu Umar
Abstract:
X-ray is the major contributor to the effective dose of both the patient and the personnel. Because of the radiological risks involved, it is usually recommended that dose to patient from X-ray be kept as low as reasonably achievable (ALARA) with adequate image quality. The implementation of quality assurance in diagnostic radiology can help greatly in achieving that, as it is a technique designed to reduce X-ray doses to patients undergoing radiological examination. In this study, quality control was carried out in six hospitals, which involved KVp test, evaluation of total filtration, test for constancy of radiation output, and check for mA linearity. Equipment used include KVp meter, Rad-check meter, aluminum sheets (0.1–1.0 mm) etc. The results of this study indicate that, the age of the X-ray machines in the hospitals ranges from 3-13 years, GHI and GH2 being the oldest and FMC being the newest. In the evaluation of total filtration, the HVL of the X-ray machines in the hospitals varied, ranging from 2.3-5.2 mm. The HVL was found to be highest in AHC (5.2 mm), while it was lowest in GH3 (2.3 mm). All HVL measurements were done at 80 KVp. The variation in voltage accuracy in the hospitals ranges from 0.3%-127.5%. It was only in GH1 that the % variation was below the allowed limit. The test for constancy of radiation output showed that, the coefficient of variation ranges from 0.005–0.550. In GH3, FMC and AHC, the coefficient of linearity were less than the allowed limit, while in GH1, GH2 and GH4 the coefficient of linearity had exceeded the allowed limit. As regard to mA linearity, FMC and AHC had their coefficients of linearity as 0.12 and 0.10 respectively, which were within the accepted limit, while GH1, GH3 and GH4 had their coefficients as 0.16, 0.69 and 0.98 respectively, which exceeded the allowed limit.Keywords: radiation, X-ray output, quality control, half-value layer, mA linearity, KVp variation
Procedia PDF Downloads 609