Search results for: half dose thrombolysis

2402 Investigating the Dose Effect of Electroacupuncture on Mice Inflammatory Pain Model

Authors: Wan-Ting Shen, Ching-Liang Hsieh, Yi-Wen Lin

Abstract:

Electroacupuncture (EA) has been reported effective for many kinds of pain and is a common treatment for acute or chronic pain. However, to date, there are limited studies examining the effect of acupuncture dosage. In our experiment, after injecting mice with Complete Freund’s Adjuvant (CFA) to induce inflammatory pain, two groups of mice were administered two different 15 min EA treatments at 2Hz. The first group received EA at a single acupuncture point (ST36, Zusanli) in both legs (two points), whereas the second group received two acupuncture points in both legs (four points) and the analgesic effect was compared. It was found that double points (ST36, Zusanli and SP6, Sanyinjiao) were significantly superior to single points (ST36, Zusanli) when evaluated using the electronic von Frey Test (mechanic) and Hargreaves’ Test (thermal). Through this study, it is expected more novel physiological mechanisms of acupuncture analgesia will be discovered.

Keywords: anti-inflammation, dose effect, electroacupuncture, pain control

Procedia PDF Downloads 156
2401 Treatment of Acid Mine Drainage with Modified Fly Ash

Authors: Sukla Saha, Alok Sinha

Abstract:

Acid mine drainage (AMD) is the generation of acidic water from active as well as abandoned mines. AMD generates due to the oxidation of pyrites present in the rock in mining areas. Sulfur oxidizing bacteria such as Thiobacillus ferrooxidans acts as a catalyst in this oxidation process. The characteristics of AMD is extreme low pH (2-3) with elevated concentration of different heavy metals such as Fe, Al, Zn, Mn, Cu and Co and anions such sulfate and chloride. AMD contaminate the ground water as well as surface water which leads to the degradation of water quality. Moreover, it carries detrimental effect for aquatic organism and degrade the environment. In the present study, AMD is treated with fly ash, modified with alkaline agent (NaOH). This modified fly ash (MFA) was experimentally proven as a very effective neutralizing agent for the treatment of AMD. It was observed that pH of treated AMD raised to 9.22 from 1.51 with 100g/L of MFA dose. Approximately, 99% removal of Fe, Al, Mn, Cu and Co took place with the same MFA dose. The treated water comply with the effluent discharge standard of (IS: 2490-1981).

Keywords: acid mine drainage, heavy metals, modified fly ash, neutralization

Procedia PDF Downloads 124
2400 A Theoretical to Conceptual Paper: The Use of Phosphodiesterase Inhibitors, Endothelin Receptor Antagonists and/or Prostacyclin Analogs in Acute Pulmonary Embolism

Authors: Ryan M. Monti, Bijal Mehta

Abstract:

In cases of massive pulmonary embolism, defined as acute pulmonary embolism presenting with systemic hypotension or right ventricular dysfunction and impending failure, there is indication that unconventional therapies, such as phosphodiesterase inhibitors, endothelin receptor antagonists, and/or prostacyclin analogs may decrease the morbidity and mortality. Based on the premise that dilating the pulmonary artery will decrease the pulmonary vascular pressure, while simultaneously decreasing the aggregation of platelets, it can be hypothesized that increased blood flow through the pulmonary artery will decrease right heart strain and subsequent morbidity and mortality. While this theory has yet to be formally studied, the recommendations for treating massive pulmonary embolism with phosphodiesterase inhibitors, endothelin receptor antagonists, and/or prostacyclin analogs in conjunction with the current standards of care in massive pulmonary embolism should be formally studied. In particular, patients with massive PE who are unable to undergo thrombolysis/surgical intervention may be the ideal population to study the use of these treatments to determine any decrease in mortality and morbidity (short term and long term).

Keywords: acute pulmonary thromboembolism, treatment of pulmonary embolism, use of phosphodiesterase inhibitors, endothelin receptor antagonists, prostacyclin analogs in PE

Procedia PDF Downloads 203
2399 Cardiac Pacemaker in a Patient Undergoing Breast Radiotherapy-Multidisciplinary Approach

Authors: B. Petrović, M. Petrović, L. Rutonjski, I. Djan, V. Ivanović

Abstract:

Objective: Cardiac pacemakers are very sensitive to radiotherapy treatment from two sources: electromagnetic influence from the medical linear accelerator producing ionizing radiation- influencing electronics within the pacemaker, and the absorption of dose to the device. On the other hand, patients with cardiac pacemakers at the place of a tumor are rather rare, and single clinic hardly has experience with the management of such patients. The widely accepted international guidelines for management of radiation oncology patients recommend that these patients should be closely monitored and examined before, during and after radiotherapy treatment by cardiologist, and their device and condition followed up. The number of patients having both cancer and pacemaker, is growing every year, as both cancer incidence, as well as cardiac diseases incidence, are inevitably growing figures. Materials and methods: Female patient, age 69, was diagnozed with valvular cardiomyopathy and got implanted a pacemaker in 2005 and prosthetic mitral valve in 1993 (cancer was diagnosed in 2012). She was stable cardiologically and came to radiation therapy department with the diagnosis of right breast cancer, with the tumor in upper lateral quadrant of the right breast. Since she had all lymph nodes positive (28 in total), she had to have irradiated the supraclavicular region, as well as the breast with the tumor bed. She previously received chemotherapy, approved by the cardiologist. The patient was estimated to be with the high risk as device was within the field of irradiation, and the patient had high dependence on her pacemaker. The radiation therapy plan was conducted as 3D conformal therapy. The delineated target was breast with supraclavicular region, where the pacemaker was actually placed, with the addition of a pacemaker as organ at risk, to estimate the dose to the device and its components as recommended, and the breast. The targets received both 50 Gy in 25 fractions (where 20% of a pacemaker received 50 Gy, and 60% of a device received 40 Gy). The electrode to the heart received between 1 Gy and 50 Gy. Verification of dose planned and delivered was performed. Results: Evaluation of the patient status according to the guidelines and especially evaluation of all associated risks to the patient during treatment was done. Patient was irradiated by prescribed dose and followed up for the whole year, with no symptoms of failure of the pacemaker device during, or after treatment in follow up period. The functionality of a device was estimated to be unchanged, according to the parameters (electrode impedance and battery energy). Conclusion: Patient was closely monitored according to published guidelines during irradiation and afterwards. Pacemaker irradiated with the full dose did not show any signs of failure despite recommendations data, but in correlation with other published data.

Keywords: cardiac pacemaker, breast cancer, radiotherapy treatment planning, complications of treatment

Procedia PDF Downloads 414
2398 Dose Measurement in Veterinary Radiology Using Thermoluminescent Dosimeter

Authors: Ava Zarif Sanayei, Sedigheh Sina

Abstract:

Radiological protection for plants and animals is an area of regulatory importance. Acute doses of 0.1 Gy/d (10 rad/d) or below are highly unlikely to produce permanent, measurable negative effects on populations or communities of plants or animals. The advancement of radio diagnostics for domestic animals, particularly dogs and cats, has gained popularity in veterinary medicine. As pets are considered to be members of the family worldwide, they are entitled to the same care and protection. It is important to have a system of radiological protection for nonhuman organisms that complies with the focus on human health as outlined in ICRP publication 19. The present study attempts to assess surface-skin entrance doses in small pets undergoing abdominal radio diagnostic procedures utilizing a direct measurements technique with a thermoluminescent dosimeter. These measurements allow the determination of the entrance skin dose (ESD) by calculating the amount of radiation absorbed by the skin during exposure. A group of Thirty TLD-100 dosimeters produced by Harshaw Company, each with a repeatability greater than 95% and calibration using ¹³⁷Cs gamma source, were utilized to measure doses to ten small pets, including cats and dogs in the radiological department in a veterinary clinic in Shiraz, Iran. Radiological procedures were performed using a portable imaging unit (Philips Super M100, Philips Medical System, Germany) to acquire images of the abdomen; ten exams of abdomen images of different pets were monitored, measuring the thicknesses of the two projections (lateral and ventrodorsal) and the distance of the X-ray source from the surface of each pet during the exams. A group of two dosimeters was used for each pet which has been stacked on their skin on the abdomen region. The outcome of this study involved medical procedures with the same kVp, mAs, and nearly identical positions for different diagnostic X-ray procedures executed over a period of two months. The result showed the mean ESD value was 260.34±50.06 µGy due to the approximate size of pets. Based on the results, the ESD value is associated with animal size, and larger animals have higher values. If a procedure doesn't require repetition, the dose can be optimized. For smaller animals, the main challenge in veterinary radiology is the dose increase caused by repetitions, which is most noticeable in the ventro-dorsal position due to the difficulty in immobilizing the animal.

Keywords: direct dose measuring, dosimetry, radiation protection, veterinary medicine

Procedia PDF Downloads 38
2397 Factors Influencing the Decision of International Tourists to Revisit Bangkok,Thailand

Authors: Taksina Bunbut, Kevin Wongleedee

Abstract:

The purposes of this research were to study factors influencing the decision of international tourists to revisit Bangkok, Thailand. A random 200 samples was collected. Half the sample group was male and the other half was female. A questionnaire was used to collect data and small in-depth interviews were also used to get their opinions about importance of tourist decision making factors. The findings revealed that the majority of respondents rated these factors at medium level of importance. The ranking showed that the first three important factors were a safe place to stay, friendly people, and clean food. The three least important factors were a convenience transportation, clean country, and child friendly. In addition there was no significance difference between male and female in their ratings of the factors of influencing the decision of international tourists to revisit Bangkok, Thailand.

Keywords: factors, international tourists, revisit, Thailand

Procedia PDF Downloads 294
2396 Analyses for Primary Coolant Pump Coastdown Phenomena for Jordan Research and Training Reactor

Authors: Yazan M. Alatrash, Han-ok Kang, Hyun-gi Yoon, Shen Zhang, Juhyeon Yoon

Abstract:

Flow coastdown phenomena are very important to secure nuclear fuel integrity during loss of off-site power accidents. In this study, primary coolant flow coastdown phenomena are investigated for the Jordan Research and Training Reactor (JRTR) using a simulation software package, Modular Modelling System (MMS). Two MMS models are built. The first one is a simple model to investigate the characteristics of the primary coolant pump only. The second one is a model for a simulation of the Primary Coolant System (PCS) loop, in which all the detailed design data of the JRTR PCS system are modelled, including the geometrical arrangement data. The same design data for a PCS pump are used for both models. Coastdown curves obtained from the two models are compared to study the PCS loop coolant inertia effect on a flow coastdown. Results showed that the loop coolant inertia effect is found to be small in the JRTR PCS loop, i.e., about one second increases in a coastdown half time required to halve the coolant flow rate. The effects of different flywheel inertia on the flow coastdown are also investigated. It is demonstrated that the coastdown half time increases with the flywheel inertia linearly. The designed coastdown half time is proved to be well above the design requirement for the fuel integrity.

Keywords: flow coastdown, loop inertia, modelling, research reactor

Procedia PDF Downloads 469
2395 A Dose Distribution Approach Using Monte Carlo Simulation in Dosimetric Accuracy Calculation for Treating the Lung Tumor

Authors: Md Abdullah Al Mashud, M. Tariquzzaman, M. Jahangir Alam, Tapan Kumar Godder, M. Mahbubur Rahman

Abstract:

This paper presents a Monte Carlo (MC) method-based dose distributions on lung tumor for 6 MV photon beam to improve the dosimetric accuracy for cancer treatment. The polystyrene which is tissue equivalent material to the lung tumor density is used in this research. In the empirical calculations, TRS-398 formalism of IAEA has been used, and the setup was made according to the ICRU recommendations. The research outcomes were compared with the state-of-the-art experimental results. From the experimental results, it is observed that the proposed based approach provides more accurate results and improves the accuracy than the existing approaches. The average %variation between measured and TPS simulated values was obtained 1.337±0.531, which shows a substantial improvement comparing with the state-of-the-art technology.

Keywords: lung tumour, Monte Carlo, polystyrene, Elekta synergy, Monaco planning system

Procedia PDF Downloads 415
2394 PET/CT Patient Dosage Assay

Authors: Gulten Yilmaz, A. Beril Tugrul, Mustafa Demir, Dogan Yasar, Bayram Demir, Bulent Buyuk

Abstract:

A Positron Emission Tomography (PET) is a radioisotope imaging technique that illustrates the organs and the metabolisms of the human body. This technique is based on the simultaneous detection of 511 keV annihilation photons, annihilated as a result of electrons annihilating positrons that radiate from positron-emitting radioisotopes that enter biological active molecules in the body. This study was conducted on ten patients in an effort to conduct patient-related experimental studies. Dosage monitoring for the bladder, which was the organ that received the highest dose during PET applications, was conducted for 24 hours. Assessment based on measuring urination activities after injecting patients was also a part of this study. The MIRD method was used to conduct dosage calculations for results obtained from experimental studies. Results obtained experimentally and theoretically were assessed comparatively.

Keywords: PET/CT, TLD, MIRD, dose measurement, patient doses

Procedia PDF Downloads 495
2393 The Instablity of TetM Gene Encode Tetracycline Resistance Gene in Lactobacillus casei FNCC 0090

Authors: Sarah Devi Silvian, Hanna Shobrina Iqomatul Haq, Fara Cholidatun Nabila, Agustin Krisna Wardani

Abstract:

Bacteria ability to survive in antibiotic is controlled by the presence of gene that encodes the antibiotic resistance protein. The instability of the antibiotic resistance gene can be observed by exposing the bacteria under the lethal dose of antibiotic. Low concentration of antibiotic can induce mutation, which may take a role in bacterial adaptation through the antibiotic concentration. Lactobacillus casei FNCC 0090 is one of the probiotic bacteria that has an ability to survive in tetracycline by expressing the tetM gene. The aims of this study are to observe the possibilities of mutation happened in L.casei FNCC 0090 by exposing in sub-lethal dose of tetracycline and also observing the instability of the tetM gene by comparing the sequence between the wild type and mutant. L.casei FNCC 0090 has a lethal dose in 60 µg/ml, low concentration is applied to induce the mutation, the range from 10 µg/ml, 15 µg/ml, 30 µg/ml, 45 µg/ml, and 50 µg/ml. L.casei FNCC 0090 is exposed to the low concentration from lowest to the highest concentration to induce the adaptation. Plasmid is isolated from the highest concentration culture which is 50 µg/ml by using modified alkali lysis method with the addition of lysozyme. The tetM gene is isolated by using PCR (Polymerase Chain Reaction) method, then PCR amplicon is purified and sequenced. Sequencing is done on both samples, wild type and mutant. Both sequences are compared and the mutations can be traced in the presence of nucleotides changes. The changing of the nucleotides means that the tetM gene is instable.

Keywords: L. casei FNCC 0090, probiotic, tetM, tetracycline

Procedia PDF Downloads 164
2392 CT Medical Images Denoising Based on New Wavelet Thresholding Compared with Curvelet and Contourlet

Authors: Amir Moslemi, Amir movafeghi, Shahab Moradi

Abstract:

One of the most important challenging factors in medical images is nominated as noise.Image denoising refers to the improvement of a digital medical image that has been infected by Additive White Gaussian Noise (AWGN). The digital medical image or video can be affected by different types of noises. They are impulse noise, Poisson noise and AWGN. Computed tomography (CT) images are subjected to low quality due to the noise. The quality of CT images is dependent on the absorbed dose to patients directly in such a way that increase in absorbed radiation, consequently absorbed dose to patients (ADP), enhances the CT images quality. In this manner, noise reduction techniques on the purpose of images quality enhancement exposing no excess radiation to patients is one the challenging problems for CT images processing. In this work, noise reduction in CT images was performed using two different directional 2 dimensional (2D) transformations; i.e., Curvelet and Contourlet and Discrete wavelet transform(DWT) thresholding methods of BayesShrink and AdaptShrink, compared to each other and we proposed a new threshold in wavelet domain for not only noise reduction but also edge retaining, consequently the proposed method retains the modified coefficients significantly that result in good visual quality. Data evaluations were accomplished by using two criterions; namely, peak signal to noise ratio (PSNR) and Structure similarity (Ssim).

Keywords: computed tomography (CT), noise reduction, curve-let, contour-let, signal to noise peak-peak ratio (PSNR), structure similarity (Ssim), absorbed dose to patient (ADP)

Procedia PDF Downloads 417
2391 Efficient Utilization of Negative Half Wave of Regulator Rectifier Output to Drive Class D LED Headlamp

Authors: Lalit Ahuja, Nancy Das, Yashas Shetty

Abstract:

LED lighting has been increasingly adopted for vehicles in both domestic and foreign automotive markets. Although this miniaturized technology gives the best light output, low energy consumption, and cost-efficient solutions for driving, the same is the need of the hour. In this paper, we present a methodology for driving the highest class two-wheeler headlamp with regulator and rectifier (RR) output. Unlike usual LED headlamps, which are driven by a battery, regulator, and rectifier (RR) driven, a low-cost and highly efficient LED Driver Module (LDM) is proposed. The positive half of magneto output is regulated and used to charge batteries used for various peripherals. While conventionally, the negative half was used for operating bulb-based exterior lamps. But with advancements in LED-based headlamps, which are driven by a battery, this negative half pulse remained unused in most of the vehicles. Our system uses negative half-wave rectified DC output from RR to provide constant light output at all RPMs of the vehicle. With the negative rectified DC output of RR, we have the advantage of pulsating DC input which periodically goes to zero, thus helping us to generate a constant DC output equivalent to the required LED load, and with a change in RPM, additional active thermal bypass circuit help us to maintain the efficiency and thermal rise. The methodology uses the negative half wave output of the RR along with a linear constant current driver with significantly higher efficiency. Although RR output has varied frequency and duty cycles at different engine RPMs, the driver is designed such that it provides constant current to LEDs with minimal ripple. In LED Headlamps, a DC-DC switching regulator is usually used, which is usually bulky. But with linear regulators, we’re eliminating bulky components and improving the form factor. Hence, this is both cost-efficient and compact. Presently, output ripple-free amplitude drivers with fewer components and less complexity are limited to lower-power LED Lamps. The focus of current high-efficiency research is often on high LED power applications. This paper presents a method of driving LED load at both High Beam and Low Beam using the negative half wave rectified pulsating DC from RR with minimum components, maintaining high efficiency within the thermal limitations. Linear regulators are significantly inefficient, with efficiencies typically about 40% and reaching as low as 14%. This leads to poor thermal performance. Although they don’t require complex and bulky circuitry, powering high-power devices is difficult to realise with the same. But with the input being negative half wave rectified pulsating DC, this efficiency can be improved as this helps us to generate constant DC output equivalent to LED load minimising the voltage drop on the linear regulator. Hence, losses are significantly reduced, and efficiency as high as 75% is achieved. With a change in RPM, DC voltage increases, which can be managed by active thermal bypass circuitry, thus resulting in better thermal performance. Hence, the use of bulky and expensive heat sinks can be avoided. Hence, the methodology to utilize the unused negative pulsating DC output of RR to optimize the utilization of RR output power and provide a cost-efficient solution as compared to costly DC-DC drivers.

Keywords: class D LED headlamp, regulator and rectifier, pulsating DC, low cost and highly efficient, LED driver module

Procedia PDF Downloads 41
2390 Factors Affecting Treatment Resilience in Patients with Oesophago-Gastric Cancers Undergoing Palliative Chemotherapy: A Literature Review

Authors: Kiran Datta, Daniella Holland-Hart, Anthony Byrne

Abstract:

Introduction: Oesophago-gastric (OG) cancers are the fifth commonest in the UK, accounting for over 12,000 deaths each year. Most patients will present at later stages of the disease, with only 21% of patients with stage 4 disease surviving longer than a year. As a result, many patients are unsuitable for curative surgery and instead receive palliative treatment to improve prognosis and symptom burden. However, palliative chemotherapy can result in significant toxicity: almost half of the patients are unable to complete their chemotherapy regimen, with this proportion rising significantly in older and frailer patients. In addition, clinical trials often exclude older and frailer patients due to strict inclusion criteria, meaning there is limited evidence to guide which patients are most likely to benefit from palliative chemotherapy. Inappropriate chemotherapy administration is at odds with the goals of palliative treatment and care, which are to improve quality of life, and this also represents a significant resource expenditure. This literature review aimed to examine and appraise evidence regarding treatment resilience in order to guide clinicians in identifying the most suitable candidates for palliative chemotherapy. Factors influencing treatment resilience were assessed, as measured by completion rates, dose reductions, and toxicities. Methods: This literature review was conducted using rapid review methodology, utilising modified systematic methods. A literature search was performed across the MEDLINE, EMBASE, and Cochrane Library databases, with results limited to papers within the last 15 years and available in English. Key inclusion criteria included: 1) participants with either oesophageal, gastro-oesophageal junction, or gastric cancers; 2) patients treated with palliative chemotherapy; 3) available data evaluating the association between baseline participant characteristics and treatment resilience. Results: Of the 2326 papers returned, 11 reports of 10 studies were included in this review after excluding duplicates and irrelevant papers. Treatment resilience factors that were assessed included: age, performance status, frailty, inflammatory markers, and sarcopenia. Age was generally a poor predictor for how well patients would tolerate chemotherapy, while poor performance status was a better indicator of the need for dose reduction and treatment non-completion. Frailty was assessed across one cohort using multiple screening tools and was an effective marker of the risk of toxicity and the requirement for dose reduction. Inflammatory markers included lymphopenia and the Glasgow Prognostic Score, which assessed inflammation and hypoalbuminaemia. Although quick to obtain and interpret, these findings appeared less reliable due to the inclusion of patients treated with palliative radiotherapy. Sarcopenia and body composition were often associated with chemotherapy toxicity but not the rate of regimen completion. Conclusion: This review demonstrates that there are numerous measures that can estimate the ability of patients with oesophago-gastric cancer to tolerate palliative chemotherapy, and these should be incorporated into clinical assessments to promote personalised decision-making around treatment. Age should not be a barrier to receiving chemotherapy and older and frailer patients should be included in future clinical trials to better represent typical patients with oesophago-gastric cancers. Decisions regarding palliative treatment should be guided by these factors identified as well as patient preference.

Keywords: frailty, oesophago-gastric cancer, palliative chemotherapy, treatment resilience

Procedia PDF Downloads 49
2389 Development of a Laboratory Laser-Produced Plasma “Water Window” X-Ray Source for Radiobiology Experiments

Authors: Daniel Adjei, Mesfin Getachew Ayele, Przemyslaw Wachulak, Andrzej Bartnik, Luděk Vyšín, Henryk Fiedorowicz, Inam Ul Ahad, Lukasz Wegrzynski, Anna Wiechecka, Janusz Lekki, Wojciech M. Kwiatek

Abstract:

Laser produced plasma light sources, emitting high intensity pulses of X-rays, delivering high doses are useful to understand the mechanisms of high dose effects on biological samples. In this study, a desk-top laser plasma soft X-ray source, developed for radio biology research, is presented. The source is based on a double-stream gas puff target, irradiated with a commercial Nd:YAG laser (EKSPLA), which generates laser pulses of 4 ns time duration and energy up to 800 mJ at 10 Hz repetition rate. The source has been optimized for maximum emission in the “water window” wavelength range from 2.3 nm to 4.4 nm by using pure gas (argon, nitrogen and krypton) and spectral filtering. Results of the source characterization measurements and dosimetry of the produced soft X-ray radiation are shown and discussed. The high brightness of the laser produced plasma soft X-ray source and the low penetration depth of the produced X-ray radiation in biological specimen allows a high dose rate to be delivered to the specimen of over 28 Gy/shot; and 280 Gy/s at the maximum repetition rate of the laser system. The source has a unique capability for irradiation of cells with high pulse dose both in vacuum and He-environment. Demonstration of the source to induce DNA double- and single strand breaks will be discussed.

Keywords: laser produced plasma, soft X-rays, radio biology experiments, dosimetry

Procedia PDF Downloads 558
2388 Medical Workforce Knowledge of Adrenaline (Epinephrine) Administration in Anaphylaxis in Adults Considerably Improved with Training in an UK Hospital from 2010 to 2017

Authors: Jan C. Droste, Justine Burns, Nithin Narayan

Abstract:

Introduction: Life-threatening detrimental effects of inappropriate adrenaline (epinephrine) administration, e.g., by giving the wrong dose, in the context of anaphylaxis management is well documented in the medical literature. Half of the fatal anaphylactic reactions in the UK are iatrogenic, and the median time to a cardio-respiratory arrest can be as short as 5 minutes. It is therefore imperative that hospital doctors of all grades have active and accurate knowledge of the correct route, site, and dosage of administration of adrenaline. Given this time constraint and the potential fatal outcome with inappropriate management of anaphylaxis, it is alarming that surveys over the last 15 years have repeatedly shown only a minority of doctors to have accurate knowledge of adrenaline administration as recommended by the UK Resuscitation Council guidelines (2008 updated 2012). This comparison of survey results of the medical workforce over several years in a small NHS District General Hospital was conducted in order to establish the effect of the employment of multiple educational methods regarding adrenaline administration in anaphylaxis in adults. Methods: Between 2010 and 2017, several education methods and tools were used to repeatedly inform the medical workforce (doctors and advanced clinical practitioners) in a single district general hospital regarding the treatment of anaphylaxis in adults. Whilst the senior staff remained largely the same cohort, junior staff had changed fully in every survey. Examples included: (i) Formal teaching -in Grand Rounds; during the junior doctors’ induction process; advanced life support courses (ii) In-situ simulation training performed by the clinical skills simulation team –several ad hoc sessions and one 3-day event in 2017 visiting 16 separate clinical areas performing an acute anaphylaxis scenario using actors- around 100 individuals from multi-disciplinary teams were involved (iii) Hospital-wide distribution of the simulation event via the Trust’s Simulation Newsletter (iv) Laminated algorithms were attached to the 'crash trolleys' (v) A short email 'alert' was sent to all medical staff 3 weeks prior to the survey detailing the emergency treatment of anaphylaxis (vi) In addition, the performance of the surveys themselves represented a teaching opportunity when gaps in knowledge could be addressed. Face to face surveys were carried out in 2010 ('pre-intervention), 2015, and 2017, in the latter two occasions including advanced clinical practitioners (ACP). All surveys consisted of convenience samples. If verbal consent to conduct the survey was obtained, the medical practitioners' answers were recorded immediately on a data collection sheet. Results: There was a sustained improvement in the knowledge of the medical workforce from 2010 to 2017: Answers improved regarding correct drug by 11% (84%, 95%, and 95%); the correct route by 20% (76%, 90%, and 96%); correct site by 40% (43%, 83%, and 83%) and the correct dose by 45% (27%, 54%, and 72%). Overall, knowledge of all components -correct drug, route, site, and dose-improved from 13% in 2010 to 62% in 2017. Conclusion: This survey comparison shows knowledge of the medical workforce regarding adrenaline administration for treatment of anaphylaxis in adults can be considerably improved by employing a variety of educational methods.

Keywords: adrenaline, anaphylaxis, epinephrine, medical education, patient safety

Procedia PDF Downloads 108
2387 Pharmacokinetic Study of Clarithromycin in Human Female of Pakistani Population

Authors: Atifa Mushtaq, Tanweer Khaliq, Hafiz Alam Sher, Asia Farid, Anila Kanwal, Maliha Sarfraz

Abstract:

The study was designed to assess the various pharmacokinetic parameters of a commercially available clarithromycin Tablet (Klaricid® 250 mg Abbot, Pakistan) in plasma sample of healthy adult female volunteers by applying a rapid, sensitive and accurate HPLC-UV analytical method. The human plasma samples were evaluated by using an isocratic High Performance Liquid Chromatography (HPLC) system of Sykam consisted of a pump with a column C18 column (250×4.6mn, 5µm) UV-detector. The mobile phase comprises of potassium dihydrogen phosphate (50 mM, pH 6.8, contained 0.7% triethylamine), methanol and acetonitrile (30:25:45, v/v/v) was delivered with injection volume of 20µL at flow rate of 1 mL/min. The detection was performed at λmax 275 nm. By applying this method, important pharmacokinetic parameters Cmax, Tmax, Area under curve (AUC), half-life (t1/2), , Volume of distribution (Vd) and Clearance (Cl) were measured. The parameters of pharmacokinetics of clarithromycin were calculated by software (APO) pharmacological analysis. Maximum plasma concentrations Cmax 2.78 ±0.33 µg/ml, time to reach maximum concentration tmax 2.82 ± 0.11 h and Area under curve AUC was 20.14 h.µg/ml. The mean ± SD values obtained for the pharmacokinetic parameters showed a significant difference in pharmacokinetic parameters observed in previous literature which emphasizes the need for dose adjustment of clarithromycin in Pakistani population.

Keywords: Pharmacokinetc, Clarothromycin, HPLC, Pakistan

Procedia PDF Downloads 82
2386 Physicochemical and Biochemical Characterization of Olea europea Var. Oleaster Oil and Determination of Its Effects on Blood Parameters

Authors: Asma Gherib, Imen Merzougui, Cherifa Henchiri

Abstract:

This present study has allowed to evaluate the physico chemical characteristics, fatty acid composition and the hypolipidemic effect of Oleaster oil Olea europea var. Oleaster, from the area of El Kala, "Eastern Algeria" on rats "Wistar albinos". The physico chemical characteristics: acidity (0,73%), peroxide value (14, 16 meqO2/kg oil) and iodine value (74,08 g iodine/100 g of oil) are consistent with international standards. The dosage of FA revealed a wealth of oil with UFA (76,7%), mainly composed of 65.43% of MUFA whose major fatty acid is oleic acid (63,57%). The experiment on rats receiving a diet rich in saturated fats and hydrogenated oils revealed that the consumption of Oleaster oil at the dose of 10 g and 20 g for 15 and 30 days improves plasma lipid profile by decreasing the rates of TC, TG, TL, and LDL-C with an increase in the rate of HDL-C serum. The importance of these effects depends on the dose and period of treatment.

Keywords: oleaster oil, fatty acid, Olea europea, oleic acid, lipid profile

Procedia PDF Downloads 451
2385 γ-Irradiation of Oat β- Glucan: Effect on Antioxidant and Antiproliferative Properties

Authors: Asima Shah, F. A. Masoodi, Adil Gani, Bilal Ahmad Ashwar

Abstract:

The present study was designed to evaluate the effect of γ-rays on the antioxidant and antiproliferative potential of β-glucan isolated from oats. The β-glucan was irradiated with 0, 2, 6, and 10 kGy by gamma ray. The samples were characterized by FT-IR, GPC, and quantitative estimation by Megazyme β-glucan assay kit. The average molecular weight of non-irradiated β-glucan was 199 kDa that decreased to 70 kDa at 10 kGy. Both FT-IR spectrum and chemical analysis revealed that the extracted β-glucan was pure having minor impurities. Antioxidant activity was evaluated by DPPH, lipid peroxidation, reducing power, metal chelating ability and oxidative DNA damage assays. Results revealed that the antioxidant activity of β-glucan increased with the increase in irradiation dose. Irradiated β-glucan also exhibited dose dependent cancer cell growth inhibition with irradiation doses. The study revealed that low molecular weight β-glucan with enhanced antioxidant and antiproliferative activities can be produced by a simple irradiation method.

Keywords: γ-irradiation, antioxidant activity, antiproliferative activity, β-glucan, oats

Procedia PDF Downloads 421
2384 Comparison of Depth of Cure and Degree of Conversion between Opus Bulk Fill and X-Tra Fill Bulk Fill Composites

Authors: Yasaman Samani, Ali Golmohammadi

Abstract:

Introduction: The degree of conversion and depth of cure affects the clinical success of resin composite restorations directly. One of the main challenges in achieving a successful composite restoration is the achievement of sufficient depth of cure. The insufficient polymerization may lead to a decrease in the physical/mechanical and biological properties of resin composites and, as a result of that, unsuccessful composite restoration. Thus, because of the importance of studying and evaluating the depth of cure and degree of conversion in bulk-fill composites, we decided to evaluate and compare the degree of conversion and depth of cure in two bulk-fill composites; x-tra fill (Voco, Germany) and Opus Bulk fill APS (FGM, Brazil). Materials and Methods: Composite resin specimens (n=10) per group were prepared as cylinder blocks (4×8 mm) with bulk-fill composites, x-tra fil (Voco, Germany) designated as Group A, and Opus Bulk fill APS (FGM, Brazil) designated as Group B. Depth of cure was determined according to “ISO 4049; Depth of Cure” method, In which each specimen were cured (iLED, Woodpecker, China) 40 seconds and FTIR spectroscopy method was used to estimate the degree of conversion of both the bulk-fill composites. The degree of conversion of monomer to polymer was estimated individually in the coronal half (Group A1 and B1) and pulpal half (Group A2 and Group B2) by dividing each specimen into two halves. The data were analyzed using a Student’s t-test and one-way ANOVA at a 5% level of significance. Results: The mean depth of cure in x-tra fil (Voco, Germany) was 3.99 (±0.16), and for Opus Bulk fill, APS (FGM, Brazil) was 2.14 (±0.3). The degree of conversion percentage in Group A1 was 82.7 (±6.1), in group A2 was 73.4 (±5.2), in group B1 was 63.3 (±4.7) and in Group B2 was 56.5 (±7.7). Statistical analysis revealed a significant difference in the depth of cure between the two bulk-fill composites with x-tra fil (Voco, Germany) higher than Opus Bulk fill APS (FGM, Brazil) (P<0.001). The degree of conversion percentage also showed a significant difference, Group A1 being higher than A2 (P=0.0085), B1, and B2 (P<0.001). Group A2 was also higher than B1 (P=0.003) and B2 (P<0.001). There was no significant difference between B1 and B2 (P=0.072). Conclusion: The results indicate that x-tra fill has more depth of cure and a higher percentage of the degree of conversion than Opus Bulk fill APS. The coronal half of x-tra fil had the highest depth of cure percentage (82.66%), and the pulpal half of Opus Bulk fill APS had the lowest percentage (56.45%). Even though both bulk-fill composite materials had an acceptable degree of conversion (55% and higher), x-tra fill has shown better results.

Keywords: depth of cure, degree of conversion, bulk-fill composite, FTIR

Procedia PDF Downloads 80
2383 The Monitor for Neutron Dose in Hadrontherapy Project: Secondary Neutron Measurement in Particle Therapy

Authors: V. Giacometti, R. Mirabelli, V. Patera, D. Pinci, A. Sarti, A. Sciubba, G. Traini, M. Marafini

Abstract:

The particle therapy (PT) is a very modern technique of non invasive radiotherapy mainly devoted to the treatment of tumours untreatable with surgery or conventional radiotherapy, because localised closely to organ at risk (OaR). Nowadays, PT is available in about 55 centres in the word and only the 20\% of them are able to treat with carbon ion beam. However, the efficiency of the ion-beam treatments is so impressive that many new centres are in construction. The interest in this powerful technology lies to the main characteristic of PT: the high irradiation precision and conformity of the dose released to the tumour with the simultaneous preservation of the adjacent healthy tissue. However, the beam interactions with the patient produce a large component of secondary particles whose additional dose has to be taken into account during the definition of the treatment planning. Despite, the largest fraction of the dose is released to the tumour volume, a non-negligible amount is deposed in other body regions, mainly due to the scattering and nuclear interactions of the neutrons within the patient body. One of the main concerns in PT treatments is the possible occurrence of secondary malignant neoplasm (SMN). While SMNs can be developed up to decades after the treatments, their incidence impacts directly life quality of the cancer survivors, in particular in pediatric patients. Dedicated Treatment Planning Systems (TPS) are used to predict the normal tissue toxicity including the risk of late complications induced by the additional dose released by secondary neutrons. However, no precise measurement of secondary neutrons flux is available, as well as their energy and angular distributions: an accurate characterization is needed in order to improve TPS and reduce safety margins. The project MONDO (MOnitor for Neutron Dose in hadrOntherapy) is devoted to the construction of a secondary neutron tracker tailored to the characterization of that secondary neutron component. The detector, based on the tracking of the recoil protons produced in double-elastic scattering interactions, is a matrix of thin scintillating fibres, arranged in layer x-y oriented. The final size of the object is 10 x 10 x 20 cm3 (squared 250µm scint. fibres, double cladding). The readout of the fibres is carried out with a dedicated SPAD Array Sensor (SBAM) realised in CMOS technology by FBK (Fondazione Bruno Kessler). The detector is under development as well as the SBAM sensor and it is expected to be fully constructed for the end of the year. MONDO will make data tacking campaigns at the TIFPA Proton Therapy Center of Trento, at the CNAO (Pavia) and at HIT (Heidelberg) with carbon ion in order to characterize the neutron component and predict the additional dose delivered on the patients with much more precision and to drastically reduce the actual safety margins. Preliminary measurements with charged particles beams and MonteCarlo FLUKA simulation will be presented.

Keywords: secondary neutrons, particle therapy, tracking detector, elastic scattering

Procedia PDF Downloads 206
2382 Effect of Dose-Dependent Gamma Irradiation on the Fatty Acid Profile of Mud Crab, Scylla Serrata: A GC-FID Study

Authors: Keethadath Arshad, Kappalli Sudha

Abstract:

Mud crab, Scylla Serrata, a commercially important shellfish with high global demand appears to be the rich source of dietary fatty acids. Its increased production through aquaculture and highly perishable nature would necessitate improved techniques for their proper preservation. Optimized irradiation has been identified as an effective method to facilitate safety and extended shelf life for a broad range of the perishable food items including finfishes and shellfishes. The present study analyzed the effects of dose-dependent gamma irradiation on the fatty acid profile of the muscle derived from the candidate species (S. serrata) at both qualitative and quantitative levels. Wild grown, average sized, intermolt male S. Serrata were gamma irradiated (^60C, 3.8kGy/ hour) at the dosage of 0.5kGy, 1.0kGy and 2.0kGy using gamma chamber. Total lipid extracted by Folch method, after methylation, were analyzed for the presence fatty acids adopting Gas Chromatograph equipped with flame ionization detector by comparing with the authentic FAME reference standards. The tissue from non-irradiated S. serrata showed the presence of 12 SFA, 6 MUFA, 8PUFA and 2 TF; PUFA includes medicinally important ω-3 FA such as C18:3, C20:5 and C22:6 and ω-6 FA such as γ- C18:3 and C20:2. Dose-dependent gamma irradiation reduced the number of detectable fatty acids (10, 8 and 8 SFA, 6, 6 and 5MUFA, 7, 7, and 6 PUFA and 1, 1, and 0 TF in 0.5kGy, 1.0kGy and 2kGy irradiated samples respectively). Major fatty acids detected in both irradiated and non-irradiated samples were as follows: SFA- C16:0, C18:0, C22:0 and C14:0; MUFA - C18:1 and C16:1and PUFA- C18:2, C20:5, C20:2 and C22:6. Irradiation doses ranging from 1-2kGy substantially reduced the ω-6 C18:3 and ω-3 C18:3. However, the omega fatty acids such as C20:5, C22:6 and C20:2 could survive even after 2kGy irradiation. Significantly, trans fat like C18:2T and C18:1T were completely disappeared upon 2kGy irradiation. From the overall observations made from the present study, it is suggested that irradiation dose up to 1kGy is optimum to maintain the fatty acid profile and eradicate the trans fat of the muscle derived from S. serrata.

Keywords: fatty acid profile, food preservation, gamma irradiation, scylla serrata

Procedia PDF Downloads 249
2381 [Keynote Talk]: Discovering Liouville-Type Problems for p-Energy Minimizing Maps in Closed Half-Ellipsoids by Calculus Variation Method

Authors: Lina Wu, Jia Liu, Ye Li

Abstract:

The goal of this project is to investigate constant properties (called the Liouville-type Problem) for a p-stable map as a local or global minimum of a p-energy functional where the domain is a Euclidean space and the target space is a closed half-ellipsoid. The First and Second Variation Formulas for a p-energy functional has been applied in the Calculus Variation Method as computation techniques. Stokes’ Theorem, Cauchy-Schwarz Inequality, Hardy-Sobolev type Inequalities, and the Bochner Formula as estimation techniques have been used to estimate the lower bound and the upper bound of the derived p-Harmonic Stability Inequality. One challenging point in this project is to construct a family of variation maps such that the images of variation maps must be guaranteed in a closed half-ellipsoid. The other challenging point is to find a contradiction between the lower bound and the upper bound in an analysis of p-Harmonic Stability Inequality when a p-energy minimizing map is not constant. Therefore, the possibility of a non-constant p-energy minimizing map has been ruled out and the constant property for a p-energy minimizing map has been obtained. Our research finding is to explore the constant property for a p-stable map from a Euclidean space into a closed half-ellipsoid in a certain range of p. The certain range of p is determined by the dimension values of a Euclidean space (the domain) and an ellipsoid (the target space). The certain range of p is also bounded by the curvature values on an ellipsoid (that is, the ratio of the longest axis to the shortest axis). Regarding Liouville-type results for a p-stable map, our research finding on an ellipsoid is a generalization of mathematicians’ results on a sphere. Our result is also an extension of mathematicians’ Liouville-type results from a special ellipsoid with only one parameter to any ellipsoid with (n+1) parameters in the general setting.

Keywords: Bochner formula, Calculus Stokes' Theorem, Cauchy-Schwarz Inequality, first and second variation formulas, Liouville-type problem, p-harmonic map

Procedia PDF Downloads 249
2380 Enhancing Skills of Mothers of Asthmatic Children in Techniques of Drug Administration

Authors: Erna Judith Roach, Nalini Bhaskaranand

Abstract:

Background & Significance: Asthma is the most common chronic disease among children. Education is the cornerstone of management of asthma to help the affected children. In India there are about 1.5- 3.0 million asthmatic children in the age group of 5-11 years. Many parents face management dilemmas in administration of medications to their children. Mothers being primary caregivers of children are often responsible for administering medications to them. The purpose of the study was to develop an educational package on techniques of drug administration for mothers of asthmatic children and determine its effectiveness in terms of improvement in skill in drug administration. Methodology: A quasi- experimental time series pre-test post -test control group design was used. Mothers of asthmatic children attending paediatric outpatient departments of selected hospitals along with their children between 5 and 12 years were included. Sample size consisted of 40 mothers in the experimental and 40 mothers in the control groups. Block randomization was used to assign samples to both the groups. The data collection instruments used were Baseline Proforma, Clinical Proforma, Daily asthma drug intake and symptoms diary and Observation Rating Scales on technique of using a metered dose inhaler with spacer; metered dose inhaler with facemask; metered dose inhaler alone and dry powder inhaler. The educational package consisted of a video and booklet on techniques of drug administration. Data were collected at baseline, 1, 3 and 6 months. Findings: The mean post-test scores in techniques of drug administration were higher than the mean pre-test scores in the experimental group in all techniques. The Friedman test (p < 0.01), Wilcoxon Signed Rank test (p < 0.008) and Mann Whitney U (p < 0.01) showed statistically significant difference in the experimental group than the control group. There was significant decrease in the average number of symptom days (11 Vs. 4 days/ month) and hospital visits (5 to 1 per month) in the experimental group when compared to the control group. Conclusion: The educational package was found to be effective in improving the skill of mothers in drug administration in all the techniques, especially with using the metered dose inhaler with spacer.

Keywords: childhood asthma, drug administration, mothers of children, inhaler

Procedia PDF Downloads 400
2379 Full-Potential Investigation of the Electronic and Magnetic Properties of CdCoTe and CdMnTe Diluted Magnetic Semiconductors

Authors: A.Zitouni, S.Bentata, B.Bouadjemi, T.Lantri, W. Benstaali, Z.Aziz, S.Cherid

Abstract:

We investigate the structural, electronic and magnetic properties of the diluted magnetic semiconductors (DMSs) CdCoTe and CdMnTe in the zinc blende phase with 25% of Co and Mn. The calculations are performed by the recent ab initio full potential augmented plane waves (FP_L/APW) method within the spin polarized density-functional theory (DFT) and the generalized gradient approximation GGA. Structural properties are determined from the total energy calculations and we found that these compounds are stable in the ferromagnetic phase. We discuss the electronic structures, total and partial densities of states and total magnetic moments. The calculated densities of states presented in this study identify the half-metallic of CdCoTe and CdMnTe.

Keywords: electronic structure, half-metallic, magnetic moment, total and partial densities of states

Procedia PDF Downloads 473
2378 A Problem on Homogeneous Isotropic Microstretch Thermoelastic Half Space with Mass Diffusion Medium under Different Theories

Authors: Devinder Singh, Rajneesh Kumar, Arvind Kumar

Abstract:

The present investigation deals with generalized model of the equations for a homogeneous isotropic microstretch thermoelastic half space with mass diffusion medium. Theories of generalized thermoelasticity Lord-Shulman (LS) Green-Lindsay (GL) and Coupled Theory (CT) theories are applied to investigate the problem. The stresses in the considered medium have been studied due to normal force and tangential force. The normal mode analysis technique is used to calculate the normal stress, shear stress, couple stresses and microstress. A numerical computation has been performed on the resulting quantity. The computed numerical results are shown graphically.

Keywords: microstretch, thermoelastic, normal mode analysis, normal and tangential force, microstress force

Procedia PDF Downloads 511
2377 Synergistic Effect of Doxorubicin-Loaded Silver Nanoparticles – Polymeric Conjugates on Breast Cancer Cells

Authors: Nancy M. El-Baz, Laila Ziko, Rania Siam, Wael Mamdouh

Abstract:

Cancer is one of the most devastating diseases, and has over than 10 million new cases annually worldwide. Despite the effectiveness of chemotherapeutic agents, their systemic toxicity and non-selective anticancer actions represent the main obstacles facing cancer curability. Due to the effective enhanced permeability and retention (EPR) effect of nanomaterials, nanoparticles (NPs) have been used as drug nanocarriers providing targeted cancer drug delivery systems. In addition, several inorganic nanoparticles such as silver (AgNPs) nanoparticles demonstrated a potent anticancer activity against different cancers. The present study aimed at formulating core-shell inorganic NPs-based combinatorial therapy based on combining the anticancer activity of AgNPs along with doxorubicin (DOX) and evaluating their cytotoxicity on MCF-7 breast cancer cells. These inorganic NPs-based combinatorial therapies were designed to (i) Target and kill cancer cells with high selectivity, (ii) Have an improved efficacy/toxicity balance, and (iii) Have an enhanced therapeutic index when compared to the original non-modified DOX with much lower dosage The in-vitro cytotoxicity studies demonstrated that the NPs-based combinatorial therapy achieved the same efficacy of non-modified DOX on breast cancer cell line, but with 96% reduced dose. Such reduction in DOX dose revealed that the combination between DOX and NPs possess a synergic anticancer activity against breast cancer. We believe that this is the first report on a synergic anticancer effect at very low dose of DOX against MCF-7 cells. Future studies on NPs-based combinatorial therapy may aid in formulating novel and significantly more effective cancer therapeutics.

Keywords: nanoparticles-based combinatorial therapy, silver nanoparticles, doxorubicin, breast cancer

Procedia PDF Downloads 408
2376 Targeting Tumour Survival and Angiogenic Migration after Radiosensitization with an Estrone Analogue in an in vitro Bone Metastasis Model

Authors: Jolene M. Helena, Annie M. Joubert, Peace Mabeta, Magdalena Coetzee, Roy Lakier, Anne E. Mercier

Abstract:

Targeting the distant tumour and its microenvironment whilst preserving bone density is important in improving the outcomes of patients with bone metastases. 2-Ethyl-3-O-sulphamoyl-estra1,3,5(10)16-tetraene (ESE-16) is an in-silico-designed 2- methoxyestradiol analogue which aimed at enhancing the parent compound’s cytotoxicity and providing a more favourable pharmacokinetic profile. In this study, the potential radiosensitization effects of ESE-16 were investigated in an in vitro bone metastasis model consisting of murine pre-osteoblastic (MC3T3-E1) and pre-osteoclastic (RAW 264.7) bone cells, metastatic prostate (DU 145) and breast (MDA-MB-231) cancer cells, as well as human umbilical vein endothelial cells (HUVECs). Cytotoxicity studies were conducted on all cell lines via spectrophotometric quantification of 3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide. The experimental set-up consisted of flow cytometric analysis of cell cycle progression and apoptosis detection (Annexin V-fluorescein isothiocyanate) to determine the lowest ESE-16 and radiation doses to induce apoptosis and significantly reduce cell viability. Subsequent experiments entailed a 24-hour low-dose ESE-16-exposure followed by a single dose of radiation. Termination proceeded 2, 24 or 48 hours thereafter. The effect of the combination treatment was investigated on osteoclasts via tartrate-resistant acid phosphatase (TRAP) activity- and actin ring formation assays. Tumour cell experiments included investigation of mitotic indices via haematoxylin and eosin staining; pro-apoptotic signalling via spectrophotometric quantification of caspase 3; deoxyribonucleic acid (DNA) damage via micronuclei analysis and histone H2A.X phosphorylation (γ-H2A.X); and Western blot analyses of bone morphogenetic protein-7 and matrix metalloproteinase-9. HUVEC experiments included flow cytometric quantification of cell cycle progression and free radical production; fluorescent examination of cytoskeletal morphology; invasion and migration studies on an xCELLigence platform; and Western blot analyses of hypoxia-inducible factor 1-alpha and vascular endothelial growth factor receptor 1 and 2. Tumour cells yielded half-maximal growth inhibitory concentration (GI50) values in the nanomolar range. ESE-16 concentrations of 235 nM (DU 145) and 176 nM (MDA-MB-231) and a radiation dose of 4 Gy were found to be significant in cell cycle and apoptosis experiments. Bone and endothelial cells were exposed to the same doses as DU 145 cells. Cytotoxicity studies on bone cells reported that RAW 264.7 cells were more sensitive to the combination treatment than MC3T3-E1 cells. Mature osteoclasts were more sensitive than pre-osteoclasts with respect to TRAP activity. However, actin ring morphology was retained. The mitotic arrest was evident in tumour and endothelial cells in the mitotic index and cell cycle experiments. Increased caspase 3 activity and superoxide production indicated pro-apoptotic signalling in tumour and endothelial cells. Increased micronuclei numbers and γ-H2A.X foci indicated increased DNA damage in tumour cells. Compromised actin and tubulin morphologies and decreased invasion and migration were observed in endothelial cells. Western blot analyses revealed reduced metastatic and angiogenic signalling. ESE-16-induced radiosensitization inhibits metastatic signalling and tumour cell survival whilst preferentially preserving bone cells. This low-dose combination treatment strategy may promote the quality of life of patients with metastatic bone disease. Future studies will include 3-dimensional in-vitro and murine in-vivo models.

Keywords: angiogenesis, apoptosis, bone metastasis, cancer, cell migration, cytoskeleton, DNA damage, ESE-16, radiosensitization.

Procedia PDF Downloads 133
2375 In Vitro Hepatoprotective and Anti-Hepatitis B Activitis of Cyperus rotundus Rhizome Fractions

Authors: Mohammad K. Parvez, Ahmed H. Arbab, Mohammed S. Al-Dosari

Abstract:

Cyperus rotendus rhizomes are used as traditional medicine, including Ayurveda in chronic liver diseases and hepatitis B. We investigated the in vitro hepatoprotective and anti-hepatitis B virus (HBV) potential of Cyperus rotundus rhizome organic and aqueous fractions. Of these, the n-butanol and aqueous fractions showed the most promising, dose-dependent hepatoprotection in DCFH-injured HepG2 cells at 48 h. DCFH-toxicated cells were recovered to about 88% and 96%, upon treatment with n-butanol and aqueous fractions (200 g/ml), respectively compared to DCFH-only treated cells. Further, C. rotundus fractions were tested for anti-HBV activities by measuring the expression levels of viral antigens (HBsAg and HBeAg) in the HepG2.2.15 culture supernatants. At 48 h post-treatment, the ethyl acetate, n-butanol and aqueous fractions showed dose-dependent inhibition wherein at a higher dose (100 g/ml), HBsAg production was reduced to 60.27%, 46.87 and 42.76%, respectively. In a time-course study, HBsAg production was inhibited up to 50% and 40% by ethyl acetate and n-butanol fractions (100 g/ml), respectively on day 5. Three three active fractions were further subjected to time-dependent inhibition of HBeAg expression, an indirect measure of HBV active DNA replication. At day 5 post-treatment, ethyl acetate and n-butanol fractions downregulated HBV replication by 44.14% and 24.70%, respectively. In conclusion, our results showed very promising hepatoprotective and anti-HBV potential of C. rotendus tubers fractions in vitro. Our data could, therefore, provide the basis for the claimed traditional use of C. rotendus for jaundice and hepatitis.

Keywords: anti-hepatitis B, cyperus rotundus, hepatitis B virus, hepatoprotection

Procedia PDF Downloads 216
2374 Liposomal Antihelmintics in Parasitology

Authors: Nina Ivanova

Abstract:

More than one third of the population and animals are infected with parasitic helminths. It is especially difficult to cure the larval forms of parasites. The larvae of Hymenolepis nana invade the villi of the intestinal mucosa. Toxocara larvae can live in the liver, heart, lungs, brain, eyes, and pancreas. Commercial antiparasitic drugs cannot guarantee a 100% cure after a single course of treatment, because parasite larvae invade the villi of the intestinal mucosa and the anthelmintics do not reach and kill cestode larvae. The aim of this work was to conduct a study of liposomal antihelminthics on the laboratory animals under the certification received from the Committee on Bioethics and Deontology. It has been checked: 1) anthelmintic activity of the liposomal form of fenasal in experimental hymenolepidosis of white mice (larval stage - Hymenolepis nana). 2) anthelmintic activity of the liposomal form of albendazole in experimental toxocariasis of white mice (in the lungs at the stage of larval migration). Since some helminths cause hemolysis of erythrocytes as we used a mixture of polar lipids developed by us with antihemolytic activity to obtain liposomes Fenasal and albendazole were included in the liposome membrane in the ratio of anthelmintic: lipids 1:10. . The average size of liposomes was 180 nm, and the concentration of lipids in liposomes was 1%. The researches were carried out on white male mice who were infected with Hymenolepis Nana invasional eggs in a peroral way with a doze of 100 eggs per animal. On the 5th day after infection, a liposomal fenasal and commercial fenasal were administered orally for comparison. The animals were observed for 15 days. Before the introduction of liposomes and on the 3rd, 5th, 15th day after the administration of the drug, studies were carried out on the presence of helminths in the organs of animals. The liposomal fenasal, when administered orally, had an anthelmintic effect on Hymenolepis Nana cysticercoids at a dose of 25 mg/kg. The percentage of efficiency was 90.06, 91.36 96.85% on days 3, 5, 15, respectively. For comparison, the commercial activity was at a dose of 200 mg/ml, which is 8 times higher than the dose of liposomal fenasal. To evaluate the anthelmintic effect of the liposomal form of albendazole in experimental toxocariasis of white mice (toxascaris in the lungs at the stage of larval migration), studies were also carried out on white mice. The animals were infected with invasive eggs of Toxocara canis, orally, at a dose of 100 eggs per animal. On the 5th day after infection, the liposomal albendazole was administered orally. The efficacy of the study dosage form was determined by counting Larva mirgans larvae in the lungs. The results obtained showed that the liposomal albendazole had the greatest anthelmintic effect on Toxocara larvae at a dose of 2.0 mg/kg, which was 3.75 times less than the therapeutic one. At the same time, the percentage of efficiency was 93.75% on the 3rd day, and 98.66% on the 5th day.

Keywords: hymenolepis, Toxocara, larvae, liposomes

Procedia PDF Downloads 84
2373 Anti-Inflammatory Activity of Topical Anthocyanins by Complexation and Niosomal Encapsulation

Authors: Aroonsri Priprem, Sucharat Limsitthichaikoon, Suttasinee Thappasarapong

Abstract:

Anthocyanins are natural pigments with effective UV protection but their topical use could be limited due to their physicochemical characteristics. An attempt to overcome such limitations by complexation of 2 major anthocyanin-rich sources, C. ternatea, and Z. mays, for investigation on potential use as topical anti-inflammatory. Cell studies indicate no cytotoxicity of the anthocyanin complex (AC) up to 1 mg/ml tested in HaCaT and human forehead fibroblasts by MTT. Croton oil-induced ear edema in Wistar rats suggests an effective dose of 5 mg/cm2 of AC as a topical anti-inflammatory in comparison to 0.5 mg/cm2 of fluocinolone acetonide. Niosomal encapsulation of the AC significantly prolonged the anti-inflammatory activity particularly at 8 h after topical application (p = 0.0001). The AC was not cytotoxic and its anti-inflammatory and activity was dose-dependent and prolonged by niosomal encapsulation. It has also shown to promote collagen type 1 production in cell culture. Thus, AC could be a potential candidate for topical anti-inflammatory agent from natural resources.

Keywords: anthocyanin complex, ear edema, inflammation, niosomes, skin

Procedia PDF Downloads 306