Search results for: standard of procedure
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6746

Search results for: standard of procedure

6746 Evaluation of Iranian Standard for Assessment of Liquefaction Potential of Cohesionless Soils Based on SPT

Authors: Reza Ziaie Moayad, Azam Kouhpeyma

Abstract:

In-situ testing is preferred to evaluate the liquefaction potential in cohesionless soils due to high disturbance during sampling. Although new in-situ methods with high accuracy have been developed, standard penetration test, the simplest and the oldest in-situ test, is still used due to the profusion of the recorded data. This paper reviews the Iranian standard of evaluating liquefaction potential in soils (codes 525) and compares the liquefaction assessment methods based on SPT results on cohesionless soil in this standard with the international standards. To this, methods for assessing liquefaction potential which are presented by Cetin et al. (2004), Boulanger and Idriss (2014) are compared with what is presented in standard 525. It is found that although the procedure used in Iranian standard of evaluating the potential of liquefaction has not been updated according to the new findings, it is a conservative procedure.

Keywords: cohesionless soil, liquefaction, SPT, standard 525

Procedia PDF Downloads 141
6745 The Role of BPSK (Consumer Dispute Settlement Body) in the Monitoring of Standard Clause Inclusion within Indonesian Customer Protection Law

Authors: Deviana Yuanitasari

Abstract:

The rapid development of world commerce and trade nowadays has created fast-paced demand in every business activities and transactions. That also includes the need for ready to use and practical form of standard contract. For the company or business owner, the use of standard contract is an alternative way to achieve economic goals faster, effectively and efficiently. In the other hand, for the consumer the practice of using standard contract usually unfavorable, because the contract clauses usually have been defined by the company and cannot be individually negotiated. That means consumer cannot influence the substances of the contract clauses. The purpose of this study is to get deeper understanding and analyze the role of Consumer Dispute Settlement Body in the monitoring of standard clause inclusion by businesses and industries within the context of practicing consumer protection law. Furthermore, this study will focus on the procedure of sanction and the effectiveness of the sanction for the business practitioners which disregard the inclusion of the prohibited standard clause. Therefore, this study will depict the law issues and other phenomenon that related with the role of Consumer Dispute Settlement Body in monitoring the inclusion of standard clause and procedure of sanction for the business practitioners that still use exemption clause within Consumer Protection Law System. This study results that BPSK has been assigned to monitor the inclusion of standard clause and settle consumer dispute. At this stage, BPSK role is passive, which means BPSK only takes an action if there are consumer complaints. The procedure of sanction is not part of BPSK tasks, since should there be a violation of standard clause; BPSK can only ask the business practitioners to remove the prohibited clause and not give a sanction. As a result, the procedure of sanction rule for the Standard Clause violation in this context can be considered as ineffective.

Keywords: standard contract, standard clause, consumer protection law, consumer dispute settlement body

Procedia PDF Downloads 299
6744 Controlling the Process of a Chicken Dressing Plant through Statistical Process Control

Authors: Jasper Kevin C. Dionisio, Denise Mae M. Unsay

Abstract:

In a manufacturing firm, controlling the process ensures that optimum efficiency, productivity, and quality in an organization are achieved. An operation with no standardized procedure yields a poor productivity, inefficiency, and an out of control process. This study focuses on controlling the small intestine processing of a chicken dressing plant through the use of Statistical Process Control (SPC). Since the operation does not employ a standard procedure and does not have an established standard time, the process through the assessment of the observed time of the overall operation of small intestine processing, through the use of X-Bar R Control Chart, is found to be out of control. In the solution of this problem, the researchers conduct a motion and time study aiming to establish a standard procedure for the operation. The normal operator was picked through the use of Westinghouse Rating System. Instead of utilizing the traditional motion and time study, the researchers used the X-Bar R Control Chart in determining the process average of the process that is used for establishing the standard time. The observed time of the normal operator was noted and plotted to the X-Bar R Control Chart. Out of control points that are due to assignable cause were removed and the process average, or the average time the normal operator conducted the process, which was already in control and free form any outliers, was obtained. The process average was then used in determining the standard time of small intestine processing. As a recommendation, the researchers suggest the implementation of the standard time established which is with consonance to the standard procedure which was adopted from the normal operator. With that recommendation, the whole operation will induce a 45.54 % increase in their productivity.

Keywords: motion and time study, process controlling, statistical process control, X-Bar R Control chart

Procedia PDF Downloads 178
6743 Lumbar Punctures: Re-Audit of Procedure Documentation Following the Introduction of a Standardised Procedure Checklist

Authors: Hayley Lawrence, Nabi Shah, Sarah Dyer

Abstract:

Aims: Lumbar punctures are a common bedside procedure performed in acute medicine. Published guidance exists on the standardised documentation of invasive procedures in order to reduce the risk of complications. The audit aim was to assess current standards of documentation in accordance with both the GMC and the National Standards for Invasive Procedures guidelines. A second cycle was conducted after introducing a standardised sticker created using current guidelines. This would assess whether the sticker improved documentation, aiming for 100% standard in each step of the procedure. Methods: An initial prospective audit of current practice was conducted over a 3-month period. Patients were identified by their presenting complaints and by colleagues assessing acute medical patients. Initial findings were presented locally, and a further prospective audit was conducted following the implementation of a standardised sticker. Results: 19 lumbar punctures were included in the first cycle and 13 procedures in the second. Pre-procedure documentation was collected for each cycle, whereby documentation of ‘Indication’ improved from 5.3% to 84.6%, ‘Consent’ from 84.2% to 100%, ‘Coagulopathy’ from 0% to 61.5%, ‘Drug Chart checked’ from 0% to 100%, ‘Position of patient’ from 26.3% to 100% and use of ‘Aseptic Technique’ from 83.3% to 100% from the first to the second cycle respectively. ‘Level of Doctor’ and ‘Supervision’ decreased from 53% to 31% and 53% to 46%, respectively, in the second cycle. Documentation of the procedure itself also demonstrated improvements, with ‘Level of Insertion’ 15.8% to 100%, ‘Name of Antiseptic Used’ 11.1% to 69.2%, ‘Local Anaesthetic Used’ 26.3% to 53.8%, ‘Needle Gauge’ 42.1% to 76.9%, ‘Number of Attempts’ 78.9% to 100% and ‘Traumatic/Atraumatic’ procedure 26.3% to 92.3%, respectively. A similar number of opening pressures were documented in each cycle at 57.9% and 53.8%, respectively, but its documentation was deemed ‘Not Applicable’ in a higher number of patients in the second cycle. Post-procedure documentation improved, with ‘Number of Samples obtained’ increasing from 52.6% to 92.3% and documentation of ‘Immediate Complications’ increasing from 78.9% to 100%. ‘Dressing Applied’ was poorly documented in the first cycle at 16.7%. This was not included on the standardised sticker, resulting in 0% documentation in the second cycle. Documentation of Clinicians’ Name and Bleep reduced from 63.2% to 15.4%, but when the name only was analysed, this increased to 84.6%. Conclusions: Standardised stickers for lumbar punctures do improve documentation and hence should result in improved patient safety. There is still room for improvement to reach 100% standard in each area, especially with respect to the clinician’s name and contact details being documented. Final adjustments will be made to the sticker before being included in a lumbar puncture kit, which will be made readily available in the acute medical wards. Future audits could be extended to include other common bedside procedures performed in acute medicine to ensure documentation of all these procedures reaches 100% standard.

Keywords: invasive procedure, lumbar puncture, medical record keeping, procedure checklist, procedure documentation, standardised documentation

Procedia PDF Downloads 57
6742 Clinical Audit of Selected Nephrology Nursing Procedures Performed in Nephrology Unit of AIIMS with a View to Develop Nephrology Nursing Procedure Protocol

Authors: Mamta Thakur, Dr. Shashi Mawar, Ms. Levis Murry, Dr. D.k.sharma

Abstract:

Aim: The aim of this study is to develop nephrology nursing procedure protocol after clinical audit of current nephrology nursing practices. Materials and methods: This descriptive observational study was conducted on 40 nurses who were working in Nephrology Department of AIIMS, New Delhi to observe their current practices to assess the existing gaps in the practice. The nurses were enrolled through total enumerative sampling. Sociodemographic profile of nurses and clinical profile for site of procedure was collected. Observation checklist was formed on the basis of standard nursing practices, which included 7 dimensions for hemodialysis procedure and 3 dimensions for procedure of assisting renal biopsy. Based on the gaps identified, nephrology nursing procedure protocol will be developed. Nurses were observed during two shifts, and each nurse was observed once. Scoring of items were done in each dimension, and for acceptable practices, nurses have to score ≥80% in each dimension. Results: Data was analyzed using descriptive statistics. Majority of nurses (73.7%) in nephrology ward and (80.9%) in hemodialysis unit have not undergone any special training in nephrology. Most of nurses (80.9%) followed the acceptable nursing practices for procedure of connection for hemodialysis. None of nurses followed the acceptable level (≥80%) of nursing practices for the procedure of predialysis assessment, the procedure for site preparation, during dialysis assessment and post dialysis assessment. None (100%) showed the acceptable level of nursing practices for all the dimensions of assisting renal biopsy procedure. Nephrology nursing procedure protocol was developed by researcher following a rigorous process, and this will reduce the gaps in the nursing practice. Conclusion: Clinical audit found that there were gaps in the existing nursing practices compared to the standardised nursing practices for procedure of hemodialysis and assisting renal biopsy, and these gaps have been addressed by the development of the protocol.

Keywords: nursing practice, nephrology nursing procedure, nursing protocol, renal biopsy, hemodialysis

Procedia PDF Downloads 63
6741 Feedback from a Service Evaluation of a Modified Intrauterine Device Insertor: A First Step to a Changement of the Standard of Iud Insertion Procedure

Authors: Desjardin, Michaels, Martinez, Ulmann

Abstract:

Copper IUD is one of the most efficient and cost-effective contraception. However, pain at insertion hampers the use of this method. This is especially unfortunate in nulliparous women, often younger, who are excellent candidates for this contraception, including Emergency Contraception. Standard insertion procedure of a copper IUD usually involves measurement of uterine cavity with an hysterometer and the use of a tenaculum in order to facilitate device insertion. Both procedures lead to patient pain which often constitutes a limitation of the method. To overcome these issues, we have developed a modified insertor combined with a copper IUD. The singular design of the inserter includes a flexible inflatable membrane technology allowing an easy access to the uterine cavity even in case of abnormal uterine positions or narrow cervical canal. Moreover, this inserter makes possible a direct IUD insertion with no hysterometry and no need for tenaculum. To assess device effectiveness and patient-reported pain, a study was conducted at two clinics in Fance with 31 individuals who wanted to use a copper IUD as contraceptive method. IUD insertions have been performed by four healthcare providers. Operators completed questionnaire and evaluated effectiveness of the procedure (including IUD correct fundal placement and other usability questions) as their satisfaction. Patient also completed questionnaire and pain during procedure was measured on a 10-cm Visual Analogue Scale (VAS). Analysis of the questionnaires indicates that correct IUD placement took place in more than 93% of women, which is a standard efficacy rate. It also demonstrates that IUD insertion resulted in no, light or moderate pain predominantly in nulliparous women. No insertion resulted in severe pain (none above 6cm on a 10-cm VAS). This translated by a high level of satisfaction from both patients and practitioners. In addition, this modified inserter allowed a simplification of the insertion procedure: correct fundal placement was ensured with no need for hysterometry (100%) prior to insertion nor for cervical tenaculum to pull on the cervix (90%). Avoidance of both procedures contributed to the decrease in pain during insertion. Taken together, the results of the study demonstrate that this device constitutes a significant advance in the use of copper IUDs for any woman. It allows a simplification of the insertion procedure: there is no need for pre-insertion hysterometry and no need for traction on the cervix with tenaculum. Increased comfort during insertion should allow a wider use of the method for nulliparous women and for emergency contraception. In addition, pain is often underestimated by practitioners, but fear of pain is obviously one of the blocking factors as indicated by the analysis of the questionnaire. This evaluation brings interesting information on the use of this modified inserter for standard copper IUD and promising perspectives to set up a changement in the standard of IUD insertion procedure.

Keywords: contraceptio, IUD, innovation, pain

Procedia PDF Downloads 48
6740 Use of Anti-Stick to Reduce Bitterness in Ultra Filtrated Chees-es(Single Packaged)

Authors: B. Khorram, M. Taslikh, R. Sattarzadeh, M. Ghazanfari

Abstract:

Bitterness is one of the most important problems in cheese processing industry all over the world. There are several reasons that bitterness may develop in cheese. With a few exceptions bitterness is generally associated with proteolysis. In this investigation, anti-stick as a neutral substance in proteolysis were considered and studied for reducing the problem. This vast survey was conducted in a big cheese production factory (in Neyshabur) and in the same procedure anti-stick as interested factor in cheeses packaging compared to standard cheeses production, one line productions (65200 packs with anti-stick were tested by 2953 persons for bitterness and another line was included the same procedure with standard cheese. In this investigate: 83% of standard packaging cheeses, compared with only28% of consumers cheese with anti-stick which confirmed bitterness. Although bitterness is generally associated with proteolysis and Microbial factors, Somatic cell, Starters play important role in generating bitterness in ultra filtrated cheeses, but based on the results the other factors such as anti-stick in packaging can be effective methods for reducing and removing unfavorable bitterness in cheese production.

Keywords: bitterness, uf cheese, anti-stick, single packaged

Procedia PDF Downloads 444
6739 A Generalized Weighted Loss for Support Vextor Classification and Multilayer Perceptron

Authors: Filippo Portera

Abstract:

Usually standard algorithms employ a loss where each error is the mere absolute difference between the true value and the prediction, in case of a regression task. In the present, we present several error weighting schemes that are a generalization of the consolidated routine. We study both a binary classification model for Support Vextor Classification and a regression net for Multylayer Perceptron. Results proves that the error is never worse than the standard procedure and several times it is better.

Keywords: loss, binary-classification, MLP, weights, regression

Procedia PDF Downloads 62
6738 A New Seperation / Precocentration and Determination Procedure Based on Solidified Floating Organic Drop Microextraction (SFODME) of Lead by Using Graphite Furnace Atomic Absorption Spectrometry

Authors: Seyda Donmez, Oya Aydin Urucu, Ece Kok Yetimoglu

Abstract:

Solidified floating organic drop microextraction was used for a preconcentration method of trace amount of lead. The analyte was complexed with 1-(2-pyridylazo)-2-naphtol and 1-undecanol, acetonitrile was added as an extraction and dispersive solvent respectively. The influences of some analytical parameters pH, volumes of extraction and disperser solvent, concentration of chelating agent, and concentration of salt were optimized. Under the optimum conditions the detection limits of Pb (II) was determined. The procedure was validated for the analysis of NCS DC 73347a hair standard reference material with satisfactory result. The developed procedure was successfully applied to food and water samples for detection of Pb (II) ions.

Keywords: analytical methods, graphite furnace atomic absorption spectrometry, heavy metals, solidified floating organic drop microextraction

Procedia PDF Downloads 241
6737 Results of an Educative Procedure by Nursing on Patients Subjected to a Transplant from Hematopoietic Parents

Authors: C. Catalina Zapata, Z. Claudia Montoya

Abstract:

Transplant from hematopoietic parents (THP) or medulla (MT) is a procedure used to replace the medulla that does not work as part of a disease or when it is destroyed either by a treatment of high medication doses against cancer or by radiation. The transplant process has three stages, a stage prior to transplant, during and after the transplant. It is held with the help of an interdisciplinary team, including nursing, carrying out mainly educative procedures to warrant the adhesion and the changes in lifestyles needed to whom will undergo this procedure. The aim of the study was to assess the results of an educative procedure by nursing, on adult patients subjected to a transplant from hematopoietic parents at a high complexity institution of Medellin city, Colombia. This study had an observational longitudinal design. According to the rules of protocol, the educative activity must be held on all patients joining the procedure. Four instruments were designed in order to collect all the information. One of them to measure the sociodemographic variables, another one to measure self-care practices, another one to measure transplant knowledge and its cares and the other one to measure the 30-day post-transplant complications. The last three instruments were applied before and after the educative procedure. A univaried analysis was carried out but the bivaried analysis was not carried out since there were not statistically meaningful differences before and after. Within the results, ten patients were evaluated. The average age was 38.2 (13.38 SD – standard deviation), 8/10 were men. Some self-care practices such us having pets and plants and consuming some specific food as well as little use of UV protection are all present in this type of patients and are not modified after the procedure. In measuring the knowledge, something stands out among the answers. It is the fact that some patients do not know what the medulla is, the nature of separating wastes at home and the need to consult about vomit and nausea. The most frequent complications during the first thirty days were: nausea, vomit, fever, and rash. They are considered to be expected within this period. Patients do not exhibit differences in their level of knowledge before and after the educative procedure by nursing. The patients’ self-care practices do not involve all the necessary ones to avoid complications. During the first 30 days, most of the complications are typical of the transplant process from hematopoietic parents.

Keywords: bone marrow transplant, education, family, nursing, patients, Transplantation of hematopoietic progenitors

Procedia PDF Downloads 97
6736 Reliability Analysis of Soil Liquefaction Based on Standard Penetration: A Case Study in Babol City

Authors: Mehran Naghizaderokni, Asscar Janalizadechobbasty

Abstract:

There are more probabilistic and deterministic liquefaction evaluation procedures in order to judge whether liquefaction will occur or not. A review of this approach reveals that there is a need for a comprehensive procedure that accounts for different sources of uncertainty in liquefaction evaluation. In fact, for the same set of input parameters, different methods provide different factors of safety and/or probabilities of liquefaction. To account for the different uncertainties, including both the model and measurement uncertainties, reliability analysis is necessary. This paper has obtained information from Standard Penetration Test (SPT) and some empirical approaches such as: Seed et al, Highway bridge of Japan approach to soil liquefaction, The Overseas Coastal Area Development Institute of Japan (OCDI) and reliability method to studying potential of liquefaction in soil of Babol city in the north of Iran are compared. Evaluation potential of liquefaction in soil of Babol city is an important issue since the soil of some area contains sand, seismic area, increasing level of underground waters and consequently saturation of soil; therefore, one of the most important goals of this paper is to gain suitable recognition of liquefaction potential and find the most appropriate procedure of evaluation liquefaction potential to decrease related damages.

Keywords: reliability analysis, liquefaction, Babol, civil, construction and geological engineering

Procedia PDF Downloads 477
6735 Procedure Model for Data-Driven Decision Support Regarding the Integration of Renewable Energies into Industrial Energy Management

Authors: M. Graus, K. Westhoff, X. Xu

Abstract:

The climate change causes a change in all aspects of society. While the expansion of renewable energies proceeds, industry could not be convinced based on general studies about the potential of demand side management to reinforce smart grid considerations in their operational business. In this article, a procedure model for a case-specific data-driven decision support for industrial energy management based on a holistic data analytics approach is presented. The model is executed on the example of the strategic decision problem, to integrate the aspect of renewable energies into industrial energy management. This question is induced due to considerations of changing the electricity contract model from a standard rate to volatile energy prices corresponding to the energy spot market which is increasingly more affected by renewable energies. The procedure model corresponds to a data analytics process consisting on a data model, analysis, simulation and optimization step. This procedure will help to quantify the potentials of sustainable production concepts based on the data from a factory. The model is validated with data from a printer in analogy to a simple production machine. The overall goal is to establish smart grid principles for industry via the transformation from knowledge-driven to data-driven decisions within manufacturing companies.

Keywords: data analytics, green production, industrial energy management, optimization, renewable energies, simulation

Procedia PDF Downloads 411
6734 Simplified Analysis Procedure for Seismic Evaluation of Tall Building at Structure and Component Level

Authors: Tahir Mehmood, Pennung Warnitchai

Abstract:

Simplified static analysis procedures such Nonlinear Static Procedure (NSP) are gaining popularity for the seismic evaluation of buildings. However, these simplified procedures accounts only for the seismic responses of the fundamental vibration mode of the structure. Some other procedures which can take into account the higher modes of vibration, lack in accuracy to determine the component responses. Hence, such procedures are not suitable for evaluating the structures where many vibration modes may participate significantly or where component responses are needed to be evaluated. Moreover, these procedures were found to either computationally expensive or tedious to obtain individual component responses. In this paper, a simplified but accurate procedure is studied. It is called the Uncoupled Modal Response History Analysis (UMRHA) procedure. In this procedure, the nonlinear response of each vibration mode is first computed, and they are later on combined into the total response of the structure. The responses of four tall buildings are computed by this simplified UMRHA procedure and compared with those obtained from the NLRHA procedure. The comparison shows that the UMRHA procedure is able to accurately compute the global responses, i.e., story shears and story overturning moments, floor accelerations and inter-story drifts as well as the component level responses of these tall buildings with heights varying from 20 to 44 stories. The required computational effort is also extremely low compared to that of the Nonlinear Response History Analysis (NLRHA) procedure.

Keywords: higher mode effects, seismic evaluation procedure, tall buildings, component responses

Procedia PDF Downloads 318
6733 Modified CUSUM Algorithm for Gradual Change Detection in a Time Series Data

Authors: Victoria Siriaki Jorry, I. S. Mbalawata, Hayong Shin

Abstract:

The main objective in a change detection problem is to develop algorithms for efficient detection of gradual and/or abrupt changes in the parameter distribution of a process or time series data. In this paper, we present a modified cumulative (MCUSUM) algorithm to detect the start and end of a time-varying linear drift in mean value of a time series data based on likelihood ratio test procedure. The design, implementation and performance of the proposed algorithm for a linear drift detection is evaluated and compared to the existing CUSUM algorithm using different performance measures. An approach to accurately approximate the threshold of the MCUSUM is also provided. Performance of the MCUSUM for gradual change-point detection is compared to that of standard cumulative sum (CUSUM) control chart designed for abrupt shift detection using Monte Carlo Simulations. In terms of the expected time for detection, the MCUSUM procedure is found to have a better performance than a standard CUSUM chart for detection of the gradual change in mean. The algorithm is then applied and tested to a randomly generated time series data with a gradual linear trend in mean to demonstrate its usefulness.

Keywords: average run length, CUSUM control chart, gradual change detection, likelihood ratio test

Procedia PDF Downloads 261
6732 Influence of Glass Plates Different Boundary Conditions on Human Impact Resistance

Authors: Alberto Sanchidrián, José A. Parra, Jesús Alonso, Julián Pecharromán, Antonia Pacios, Consuelo Huerta

Abstract:

Glass is a commonly used material in building; there is not a unique design solution as plates with a different number of layers and interlayers may be used. In most façades, a security glazing have to be used according to its performance in the impact pendulum. The European Standard EN 12600 establishes an impact test procedure for classification under the point of view of the human security, of flat plates with different thickness, using a pendulum of two tires and 50 kg mass that impacts against the plate from different heights. However, this test does not replicate the actual dimensions and border conditions used in building configurations and so the real stress distribution is not determined with this test. The influence of different boundary conditions, as the ones employed in construction sites, is not well taking into account when testing the behaviour of safety glazing and there is not a detailed procedure and criteria to determinate the glass resistance against human impact. To reproduce the actual boundary conditions on site, when needed, the pendulum test is arranged to be used "in situ", with no account for load control, stiffness, and without a standard procedure. Fracture stress of small and large glass plates fit a Weibull distribution with quite a big dispersion so conservative values are adopted for admissible fracture stress under static loads. In fact, test performed for human impact gives a fracture strength two or three times higher, and many times without a total fracture of the glass plate. Newest standards, as for example DIN 18008-4, states for an admissible fracture stress 2.5 times higher than the ones used for static and wing loads. Now two working areas are open: a) to define a standard for the ‘in situ’ test; b) to prepare a laboratory procedure that allows testing with more real stress distribution. To work on both research lines a laboratory that allows to test medium size specimens with different border conditions, has been developed. A special steel frame allows reproducing the stiffness of the glass support substructure, including a rigid condition used as reference. The dynamic behaviour of the glass plate and its support substructure have been characterized with finite elements models updated with modal tests results. In addition, a new portable impact machine is being used to get enough force and direction control during the impact test. Impact based on 100 J is used. To avoid problems with broken glass plates, the test have been done using an aluminium plate of 1000 mm x 700 mm size and 10 mm thickness supported on four sides; three different substructure stiffness conditions are used. A detailed control of the dynamic stiffness and the behaviour of the plate is done with modal tests. Repeatability of the test and reproducibility of results prove that procedure to control both, stiffness of the plate and the impact level, is necessary.

Keywords: glass plates, human impact test, modal test, plate boundary conditions

Procedia PDF Downloads 279
6731 Design and Implementation of a Wearable Artificial Kidney Prototype for Home Dialysis

Authors: R. A. Qawasma, F. M. Haddad, H. O. Salhab

Abstract:

Hemodialysis is a life-preserving treatment for a number of patients with kidney failure. The standard procedure of hemodialysis is three times a week during the hemodialysis procedure, the patient usually suffering from many inconvenient, exhausting feeling and effect on the heart and cardiovascular system are the most common signs. This paper provides a solution to reduce the previous problems by designing a wearable artificial kidney (WAK) taking in consideration a minimization the size of the dialysis machine. The WAK system consists of two circuits: blood circuit and dialysate circuit. The blood from the patient is filtered in the dialyzer before returning back to the patient. Several parameters using an advanced microcontroller and array of sensors. WAK equipped with visible and audible alarm system to aware the patients if there is any problem.

Keywords: artificial kidney, home dialysis, renal failure, wearable kidney

Procedia PDF Downloads 204
6730 The Preparation of 2H-Indazolo [2, 1-b] Phthalazinetriones by One-Pot 4,4ʹ-Bipyridinium Dichloride Ordered Mesoporous Silica

Authors: Aigin Bashti

Abstract:

Preparation of multicomponent reactions (MCRs) via a simple one-pot strategy is considered a novel procedure which has attracted a lot of interest from organic and medicinal chemists. Due to the great importance of phthalazide triones, it was decided to introduce a novel and cost-effective green procedure for the preparation of these derivatives. In this methodology, an efficient 4,4ʹ-Bipyridinium Dichloride Ordered Mesoporous Silica functionalized catalyst (BP-SBA-15) was utilized. The catalyst was characterized by X-ray diffraction analysis (XRD), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), thermo-gravimetric analysis (TGA), and Fourier-transform infrared spectroscopy (FT-IR) analysis. In conclusion, it should be mentioned that this methodology has some advantages, including short reaction time, high yield of the products, recyclable catalyst, green procedure, and facile work-up procedure. The catalyst was successfully utilized for the one-pot preparation of various phthalazinetrione derivatives.

Keywords: dimedone, green procedure, multicomponent reactions, phthalhydrazide

Procedia PDF Downloads 64
6729 Seismic Retrofit of Rectangular Columns Using Fiber Reinforced Polymers

Authors: E. L. Elghazy, A. M. Sanad, M. G. Ghoneim

Abstract:

Over the past two decades research has shown that fiber reinforced polymers can be efficiently, economically and safely used for strengthening and rehabilitation of reinforced concrete (RC) structures. Designing FRP confined concrete columns requires reliable analytical tools that predict the level of performance and ductility enhancement. A numerical procedure is developed aiming at determining the type and thickness of FRP jacket needed to achieve a certain level of ductility enhancement. The procedure starts with defining the stress strain curve, which is used to obtain moment curvature relationship then displacement ductility ratio of reinforced concrete cross-sections subjected to bending moment and axial force. Three sets of published experimental tests were used to validate the numerical procedure. Comparisons between predicted results obtained by using the proposed procedure and actual results of experimental tests proved the reliability of the proposed procedure.

Keywords: columns, confinement, ductility, FRP, numerical

Procedia PDF Downloads 421
6728 Numerical Analysis of Fire Performance of Timber Structures

Authors: Van Diem Thi, Mourad Khelifa, Mohammed El Ganaoui, Yann Rogaume

Abstract:

An efficient numerical method has been developed to incorporate the effects of heat transfer in timber panels on partition walls exposed to real building fires. The procedure has been added to the software package Abaqus/Standard as a user-defined subroutine (UMATHT) and has been verified using both time-and spatially dependent heat fluxes in two- and three-dimensional problems. The aim is to contribute to the development of simulation tools needed to assist structural engineers and fire testing laboratories in technical assessment exercises. The presented method can also be used under the developmental stages of building components to optimize performance in real fire conditions. The accuracy of the used thermal properties and the finite element models was validated by comparing the predicted results with three different available fire tests in literature. It was found that the model calibrated to results from standard fire conditions provided reasonable predictions of temperatures within assemblies exposed to real building fire.

Keywords: Timber panels, heat transfer, thermal properties, standard fire tests

Procedia PDF Downloads 302
6727 An Audit of the Care in Recovery in Women after an Obstetrics Procedure

Authors: A. Haddick, A. Soltan

Abstract:

Background: During the period of recovery from an operative obstetric procedure, a woman is not only at risk of the life-threatening complications accompanying labour but also those associated with surgery and anaesthesia. It is speculated that women in the recovery area may receive a lower standard of care over a night shift. Thus obstetric recovery room care should be evaluated regularly to ensure all women receive an equally high standard of care 24/7. Aim: The aim of this audit was to undertake an audit in the Liverpool Women’s Hospital on the care in recovery, and to ascertain the extent to which the standards were met. This audit included the full audit cycle. Method: Standards were taken from the AAGBI, RCOA, NICE and CNST guidelines. There were 12 standards including appropriate documentation of vital signs and appropriate length of stay after surgery. Notes from 100 patients were analysed from March 2011-March 2012. There were 52 day notes and 48 night notes; these were accessed to gain the relevant data. In the re audit 35 notes were accessed from March 14-September 14. Results: The Liverpool Women’s Hospital met in total 10 of these standards. 10 were met during the day shift (83%) and 0 met during the night shift. In the re audit, there was a significant improvement in the standards met at night. 9 of the standards were met during the day and 7 of the standards were met at night. Clearly there are still improvements to be made. Conclusions: In the original audit, an audit action plan was formulated. This was following discussion of the results of this audit in an MDT meeting and presentation with a consultant Obstetrician, the head of Midwifery, the head of Obstetrics theatres and a recovery nurse. This audit will be further discussed in the Liverpool Woman's Hospital in July 2015 for further implementation for improvement.

Keywords: care, recovery, room, women

Procedia PDF Downloads 278
6726 The Grand Unified Theory of Everything as a Generalization to the Standard Model Called as the General Standard Model

Authors: Amir Deljoo

Abstract:

The endeavor to comprehend the existence have been the center of thought for human in form of different disciplines and now basically in physics as the theory of everything. Here, after a brief review of the basic frameworks of thought, and a history of thought since ancient up to present, a logical methodology is presented based on a core axiom after which a function, a proto-field and then a coordinates are explained. Afterwards a generalization to Standard Model is proposed as General Standard Model which is believed to be the base of the Unified Theory of Everything.

Keywords: general relativity, grand unified theory, quantum mechanics, standard model, theory of everything

Procedia PDF Downloads 66
6725 Variable Selection in a Data Envelopment Analysis Model by Multiple Proportions Comparison

Authors: Jirawan Jitthavech, Vichit Lorchirachoonkul

Abstract:

A statistical procedure using multiple comparisons test for proportions is proposed for variable selection in a data envelopment analysis (DEA) model. The test statistic in the multiple comparisons is the proportion of efficient decision making units (DMUs) in a DEA model. Three methods of multiple comparisons test for proportions: multiple Z tests with Bonferroni correction, multiple tests in 2Xc crosstabulation and the Marascuilo procedure, are used in the proposed statistical procedure of iteratively eliminating the variables in a backward manner. Two simulation populations of moderately and lowly correlated variables are used to compare the results of the statistical procedure using three methods of multiple comparisons test for proportions with the hypothesis testing of the efficiency contribution measure. From the simulation results, it can be concluded that the proposed statistical procedure using multiple Z tests for proportions with Bonferroni correction clearly outperforms the proposed statistical procedure using the remaining two methods of multiple comparisons and the hypothesis testing of the efficiency contribution measure.

Keywords: Bonferroni correction, efficient DMUs, Marascuilo procedure, Pastor et al. method, 2xc crosstabulation

Procedia PDF Downloads 276
6724 A Comparative Study of High Order Rotated Group Iterative Schemes on Helmholtz Equation

Authors: Norhashidah Hj. Mohd Ali, Teng Wai Ping

Abstract:

In this paper, we present a high order group explicit method in solving the two dimensional Helmholtz equation. The presented method is derived from a nine-point fourth order finite difference approximation formula obtained from a 45-degree rotation of the standard grid which makes it possible for the construction of iterative procedure with reduced complexity. The developed method will be compared with the existing group iterative schemes available in literature in terms of computational time, iteration counts, and computational complexity. The comparative performances of the methods will be discussed and reported.

Keywords: explicit group method, finite difference, helmholtz equation, rotated grid, standard grid

Procedia PDF Downloads 424
6723 Evaluation of Complications after Colostomy Procedure and Related Factors in Cipto Mangunkusumo Hospital since 2012-2014

Authors: Alldila Hendy, Agi Satria

Abstract:

Background: A colostomy procedure is an important part in the management of surgical procedures in some diseases involving the gastrointestinal tract. So it is necessary to find the factors that influence the occurrence of complications. Methods: This is a retrospective cross-sectional analytic study in Cipto Mangunkusumo Hospital noting medical records of patients after the colostomy from January 2012 to December 2014 at the Division of Digestive Surgery. Results: In 136 cases of post-colostomy, 66 cases have complications, 14 is early-onset, and 52 is late-onset. 70 is without complications. Most complications are dermatitis, which is 31 (22.8%), cases of infection/abscess/fistula and intestinal obstruction are 13 (9.6%) and 5 patients (4.4%). A rare complication is colostomy retraction by 2 patients (1.5%), colostomy prolapse and necrosis/gangrene, which is only 3 patients (2.2%). A colostomy procedure in emergency surgery is riskier than elective surgery for complications after colostomy (p < 0.007, OR 2.85), Based on the operator who performs a colostomy procedure, the consultant had a lower risk of complications than fellow or resident (p < 0.0001). Based on the age factor, where the age of about 50 years has a risk of complications after colostomy (p < 0.018). Conclusion: The timing of operation (emergency or elective), age, and operator who perform a colostomy procedure have a significant relationship with an increased prevalence of complications after colostomy in RSCM.

Keywords: colostomy, complications, factors, procedure

Procedia PDF Downloads 245
6722 Polish Adversarial Trial: Analysing the Fairness of New Model of Appeal Proceedings in the Context of Delivered Research

Authors: Cezary Kulesza, Katarzyna Lapinska

Abstract:

Regarding the nature of the notion of fair trial, one must see the source of the fair trial principle in the following acts of international law: art. 6 of the ECHR of 1950 and art.14 the International Covenant on Civil and Political Rights of 1966, as well as in art. 45 of the Polish Constitution. However, the problem is that the above-mentioned acts essentially apply the principle of a fair trial to the main hearing and not to appeal proceedings. Therefore, the main thesis of the work is to answer the question whether the Polish model of appeal proceedings is fair. The paper presents the problem of fair appeal proceedings in Poland in comparative perspective. Thus, the authors discuss the basic features of English, German and Russian appeal systems. The matter is also analysed in the context of the last reforms of Polish criminal procedure, because since 2013 Polish parliament has significantly changed criminal procedure almost three times: by the Act of 27th September, 2013, the Act of 20th February, 2015 which came into effect on 1st July, 2015 and the Act of 11th March, 2016. The most astonishing is that these three amendments have been varying from each other – changing Polish criminal procedure to more adversarial one and then rejecting all measures just involved in previous acts. Additional intent of the Polish legislator was amending the forms of plea bargaining: conviction of the defendant without trial or voluntary submission to a penalty, which were supposed to become tools allowing accelerating the criminal process and, at the same time, implementing the principle of speedy procedure. The next part of the paper will discuss the matter, how the changes of plea bargaining and the main trial influenced the appellate procedure in Poland. The authors deal with the right to appeal against judgments issued in negotiated case-ending settlements in the light of Art. 2 of Protocol No. 7 to the ECHR and the Polish Constitution. The last part of the presentation will focus on the basic changes in the appeals against judgments issued after the main trial. This part of the paper also presents the results of examination of court files held in the Polish Appeal Courts in Białystok, Łódź and Warsaw. From these considerations it is concluded that the Polish CCP of 1997 in ordinary proceedings basically meets both standards: the standard adopted in Protocol No. 7 of the Convention and the Polish constitutional standard. But the examination of case files shows in particular the following phenomena: low effectiveness of appeals and growing stability of the challenged judgments of district courts, extensive duration of appeal proceedings and narrow scope of evidence proceedings before the appellate courts. On the other hand, limitations of the right to appeal against the judgments issued in consensual modes of criminal proceedings justify the fear that such final judgments may violate the principle of criminal accurate response or the principle of material truth.

Keywords: adversarial trial, appeal, ECHR, England, evidence, fair trial, Germany, Polish criminal procedure, reform, Russia

Procedia PDF Downloads 118
6721 A Standard Operating Procedure (SOP) for Forensic Soil Analysis: Tested Using a Simulated Crime Scene

Authors: Samara A. Testoni, Vander F. Melo, Lorna A. Dawson, Fabio A. S. Salvador

Abstract:

Soil traces are useful as forensic evidence due to their potential to transfer and adhere to different types of surfaces on a range of objects or persons. The great variability expressed by soil physical, chemical, biological and mineralogical properties show soil traces as complex mixtures. Soils are continuous and variable, no two soil samples being indistinguishable, nevertheless, the complexity of soil characteristics can provide powerful evidence for comparative forensic purposes. This work aimed to establish a Standard Operating Procedure (SOP) for forensic soil analysis in Brazil. We carried out a simulated crime scene with double blind sampling to calibrate the sampling procedures. Samples were collected at a range of locations covering a range of soil types found in South of Brazil: Santa Candida and Boa Vista, neighbourhoods from Curitiba (State of Parana) and in Guarani and Guaraituba, neighbourhoods from Colombo (Curitiba Metropolitan Region). A previously validated sequential analyses of chemical, physical and mineralogical analyses was developed in around 2 g of soil. The suggested SOP and the sequential range of analyses were effective in grouping the samples from the same place and from the same parent material together, as well as successfully discriminated samples from different locations and originated from different rocks. In addition, modifications to the sample treatment and analytical protocol can be made depending on the context of the forensic work.

Keywords: clay mineralogy, forensic soils analysis, sequential analyses, kaolinite, gibbsite

Procedia PDF Downloads 218
6720 An Automated Procedure for Estimating the Glomerular Filtration Rate and Determining the Normality or Abnormality of the Kidney Stages Using an Artificial Neural Network

Authors: Hossain A., Chowdhury S. I.

Abstract:

Introduction: The use of a gamma camera is a standard procedure in nuclear medicine facilities or hospitals to diagnose chronic kidney disease (CKD), but the gamma camera does not precisely stage the disease. The authors sought to determine whether they could use an artificial neural network to determine whether CKD was in normal or abnormal stages based on GFR values (ANN). Method: The 250 kidney patients (Training 188, Testing 62) who underwent an ultrasonography test to diagnose a renal test in our nuclear medical center were scanned using a gamma camera. Before the scanning procedure, the patients received an injection of ⁹⁹ᵐTc-DTPA. The gamma camera computes the pre- and post-syringe radioactive counts after the injection has been pushed into the patient's vein. The artificial neural network uses the softmax function with cross-entropy loss to determine whether CKD is normal or abnormal based on the GFR value in the output layer. Results: The proposed ANN model had a 99.20 % accuracy according to K-fold cross-validation. The sensitivity and specificity were 99.10 and 99.20 %, respectively. AUC was 0.994. Conclusion: The proposed model can distinguish between normal and abnormal stages of CKD by using an artificial neural network. The gamma camera could be upgraded to diagnose normal or abnormal stages of CKD with an appropriate GFR value following the clinical application of the proposed model.

Keywords: artificial neural network, glomerular filtration rate, stages of the kidney, gamma camera

Procedia PDF Downloads 65
6719 Virtual Dimension Analysis of Hyperspectral Imaging to Characterize a Mining Sample

Authors: L. Chevez, A. Apaza, J. Rodriguez, R. Puga, H. Loro, Juan Z. Davalos

Abstract:

Virtual Dimension (VD) procedure is used to analyze Hyperspectral Image (HIS) treatment-data in order to estimate the abundance of mineral components of a mining sample. Hyperspectral images coming from reflectance spectra (NIR region) are pre-treated using Standard Normal Variance (SNV) and Minimum Noise Fraction (MNF) methodologies. The endmember components are identified by the Simplex Growing Algorithm (SVG) and after adjusted to the reflectance spectra of reference-databases using Simulated Annealing (SA) methodology. The obtained abundance of minerals of the sample studied is very near to the ones obtained using XRD with a total relative error of 2%.

Keywords: hyperspectral imaging, minimum noise fraction, MNF, simplex growing algorithm, SGA, standard normal variance, SNV, virtual dimension, XRD

Procedia PDF Downloads 110
6718 ¹⁸F-FDG PET/CT Impact on Staging of Pancreatic Cancer

Authors: Jiri Kysucan, Dusan Klos, Katherine Vomackova, Pavel Koranda, Martin Lovecek, Cestmir Neoral, Roman Havlik

Abstract:

Aim: The prognosis of patients with pancreatic cancer is poor. The median of survival after establishing diagnosis is 3-11 months without surgical treatment, 13-20 months with surgical treatment depending on the disease stage, 5-year survival is less than 5%. Radical surgical resection remains the only hope of curing the disease. Early diagnosis with valid establishment of tumor resectability is, therefore, the most important aim for patients with pancreatic cancer. The aim of the work is to evaluate the contribution and define the role of 18F-FDG PET/CT in preoperative staging. Material and Methods: In 195 patients (103 males, 92 females, median age 66,7 years, 32-88 years) with a suspect pancreatic lesion, as part of the standard preoperative staging, in addition to standard examination methods (ultrasonography, contrast spiral CT, endoscopic ultrasonography, endoscopic ultrasonographic biopsy), a hybrid 18F-FDG PET/CT was performed. All PET/CT findings were subsequently compared with standard staging (CT, EUS, EUS FNA), with peroperative findings and definitive histology in the operated patients as reference standards. Interpretation defined the extent of the tumor according to TNM classification. Limitations of resectability were local advancement (T4) and presence of distant metastases (M1). Results: PET/CT was performed in a total of 195 patients with a suspect pancreatic lesion. In 153 patients, pancreatic carcinoma was confirmed and of these patients, 72 were not indicated for radical surgical procedure due to local inoperability or generalization of the disease. The sensitivity of PET/CT in detecting the primary lesion was 92.2%, specificity was 90.5%. A false negative finding in 12 patients, a false positive finding was seen in 4 cases, positive predictive value (PPV) 97.2%, negative predictive value (NPV) 76,0%. In evaluating regional lymph nodes, sensitivity was 51.9%, specificity 58.3%, PPV 58,3%, NPV 51.9%. In detecting distant metastases, PET/CT reached a sensitivity of 82.8%, specificity was 97.8%, PPV 96.9%, NPV 87.0%. PET/CT found distant metastases in 12 patients, which were not detected by standard methods. In 15 patients (15.6%) with potentially radically resectable findings, the procedure was contraindicated based on PET/CT findings and the treatment strategy was changed. Conclusion: PET/CT is a highly sensitive and specific method useful in preoperative staging of pancreatic cancer. It improves the selection of patients for radical surgical procedures, who can benefit from it and decreases the number of incorrectly indicated operations.

Keywords: cancer, PET/CT, staging, surgery

Procedia PDF Downloads 220
6717 Full Analytical Procedure to Derive P-I Diagram of a Steel Beam under Blast Loading

Authors: L. Hamra, J. F. Demonceau, V. Denoël

Abstract:

The aim of this paper is to study a beam extracted from a frame and subjected to blast loading. The demand of ductility depends on six dimensionless parameters: two related to the blast loading, two referring to the bending behavior of the beam and two corresponding to the dynamic behavior of the rest of the structure. We develop a full analytical procedure that provides the ductility demand as a function of these six dimensionless parameters.

Keywords: analytical procedure, blast loading, membrane force, P-I diagram

Procedia PDF Downloads 399