219 Ontology-Driven Generation of Radiation Protection Procedures

Authors: Chamseddine Barki, Salam Labidi, Hanen Boussi Rahmouni

Abstract:

In this article, we present the principle and suitable methodology for the design of a medical ontology that highlights the radiological and dosimetric knowledge, applied in diagnostic radiology and radiation-therapy. Our ontology, which we named «Onto.Rap», is the subject of radiation protection in medical and radiology centers by providing a standardized regulatory oversight. Thanks to its added values of knowledge-sharing, reuse and the ease of maintenance, this ontology tends to solve many problems. Of which we name the confusion between radiological procedures a practitioner might face while performing a patient radiological exam. Adding to it, the difficulties they might have in interpreting applicable patient radioprotection standards. Here, the ontology, thanks to its concepts simplification and expressiveness capabilities, can ensure an efficient classification of radiological procedures. It also provides an explicit representation of the relations between the different components of the studied concept. In fact, an ontology based-radioprotection expert system, when used in radiological center, could implement systematic radioprotection best practices during patient exam and a regulatory compliance service auditing afterwards.

Keywords: knowledge, ontology, radiation protection, radiology

Procedia PDF Downloads 284
218 Spectral Anomaly Detection and Clustering in Radiological Search

Authors: Thomas L. McCullough, John D. Hague, Marylesa M. Howard, Matthew K. Kiser, Michael A. Mazur, Lance K. McLean, Johanna L. Turk

Abstract:

Radiological search and mapping depends on the successful recognition of anomalies in large data sets which contain varied and dynamic backgrounds. We present a new algorithmic approach for real-time anomaly detection which is resistant to common detector imperfections, avoids the limitations of a source template library and provides immediate, and easily interpretable, user feedback. This algorithm is based on a continuous wavelet transform for variance reduction and evaluates the deviation between a foreground measurement and a local background expectation using methods from linear algebra. We also present a technique for recognizing and visualizing spectrally similar clusters of data. This technique uses Laplacian Eigenmap Manifold Learning to perform dimensional reduction which preserves the geometric "closeness" of the data while maintaining sensitivity to outlying data. We illustrate the utility of both techniques on real-world data sets.

Keywords: radiological search, radiological mapping, radioactivity, radiation protection

Procedia PDF Downloads 669
217 Classifications of Neuroscientific-Radiological Findings on “Practicing” in Mathematics Learning

Authors: Felicitas Pielsticker, Christoph Pielsticker, Ingo Witzke

Abstract:

Many people know ‘Mathematics needs practice!’ statement or similar ones from their mathematics lessons. It seems important to practice when learning mathematics. At the same time, it also seems important to practice how to learn mathematics. This paper places neuroscientific-radiological findings on “practicing” while learning mathematics in a context of mathematics education. To accomplish this, we use a literature-based discussion of our case study on practice. We want to describe neuroscientific-radiological findings in the context of mathematics education and point out stimulating connections between both perspectives. From a connective perspective we expect incentives that lead discussions in future research in the field of mathematics education.

Keywords: functional magnetic resonance imaging, fMRI, education, mathematics learning, practicing

Procedia PDF Downloads 302
216 Assessment of Radiological Dose for Th-232 Laboratory Accumulated in Tropical Freshwater Fish

Authors: Zal U’yun Wan Mahmood, Norfaizal Mohamed, Nita Salina Abu Bakar, Yii Mei Wo, Abdul Kadir Ishak, Mohamad Noh Sawon, Mohd Tarmizi Ishak, Khairul Nizam Razali

Abstract:

The study of thorium radiotracer bioaccumulation in the whole body tropical freshwater fish (Anabas testudeneus; climb pearch) was performed. The objective of this study was to evaluate the effect of different Th-232 activity concentration andradiological dose in Anabas testudeneus under the laboratory bioaccumulation condition. Anabas testudeneus adults were exposed to different waterborne Th-232 levels: 0 BqL-1 (control), 50 BqL-1, 100 BqL-1,150 BqL-1and 200 BqL-1for 30 days. Radionuclide concentration ratios between the whole body levels and water levels were calculated and; total dose rates and risk quotients using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive decrease of Th concentration ratio. Meanwhile, the total dose rate (internal and external) in the whole body of Anabas testudeneus less than the ERICA dose rate screening value of 10 µGyh-1 and the risk quotient less than one. Thus, the findings can be concluded that the radiological dose of Th-232 to Anabas testudeneus is a very low probability and the situation may be considered to be of negligible radiological concern.

Keywords: Anabas testudeneus, bioaccumulation, radiological dose, Th-232

Procedia PDF Downloads 292
215 Salter Pelvic Osteotomy for the Treatment of Developmental Dysplasia of the Hip: Assessment of Postoperative Results and Risk Factors

Authors: Suvorov Vasyl, Filipchuk Viktor

Abstract:

Background: If non-surgical treatment of developmental dysplasia of the hip (DDH) fails or if DDH is late-detected, surgery is necessary. Salter pelvic osteotomy (SPO) is an effective surgical option for such cases. The objectives of this study were to assess the results after SPO, evaluate risk factors, and reveal those radiological parameters that may correlate with the results. Mid- and long-term postoperative results after SPO in 17 patients (22 hip joints) were analyzed. Risk factors included those that do not depend on the surgeon (patient's age, value of the acetabular index (AI) preoperatively, DDH Tonnis grade) and those that depend on the surgeon (amount of AI correction). To radiological parameters which may correlate with the amount of AI correction, we referred distance "d" and the lateral rotation angle. Results: SPO allows performing AI correction in ranges 24.1 ± 6.5°. Excellent and good clinical results were obtained in 95.5% of patients; excellent and good radiological results in 86.4% of patients. Risk factors that do not depend on the surgeon were older patient’s age and higher preoperative AI values (p < 0.05). The risk factor that depends on the surgeon was the amount of AI correction (p < 0.05). The distance "d" was recognized as a radiological parameter that may indicate sufficient AI correction (p < 0.05). Conclusion: In older patients with a higher preoperative AI value, the results will be predictably worse. The surgeon may influence the result with a greater amount of AI correction (which may also be indicated radiologically by the distance "d" values).

Keywords: developmental dysplasia of the hip, results, risk factor, pelvic osteotomy, salter osteotomy

Procedia PDF Downloads 102
214 Correlation Study between Clinical and Radiological Findings in Knee Osteoarthritis

Authors: Nabil A. A. Mohamed, Alaa A. A. Balbaa, Khaled E. Ayad

Abstract:

Osteoarthritis (OA) of the knee is the most common form of arthritis and leads to more activity limitations (e.g., disability in walking and stair climbing) than any other disease, especially in the elderly. Recently, impaired proprioceptive accuracy of the knee has been proposed as a local factor in the onset and progression of radiographic knee OA (ROA). Purpose: To compare the clinical and radiological findings in healthy with that of knee OA. Also, to determine if there is a correlation between the clinical and radiological findings in patients with knee OA. Subjects: Fifty one patients diagnosed as unilateral or bilateral knee OA with age ranged between 35-70 years, from both gender without any previous history of knee trauma or surgery, and twenty one normal subjects with age ranged from 35 - 68 years. METHODS: peak torque/body weight (PT/BW) was recorded from knee extensors at isokinetic isometric mode at angle of 45 degree. Also, the Absolute Angular Error was recorded at 45O and 30O to measure joint position sense (JPS). They made anteroposterior (AP) plain X-rays from standing semiflexed knee position and their average score of Timed Up and Go test(TUG) and WOMAC were recorded as a measure of knee pain, stiffness and function. Comparison between the mean values of different variables in the two groups was performed using unpaired student t test. The P value less or equal to 0.05 was considered significant. Results: There were significant differences between the studied variables between the experimental and control groups except the values of AAE at 30O. Also, there were no significant correlation between the clinical findings (pain, function, muscle strength and proprioception) and the severity of arthritic changes in X-rays. CONCLUSION: From the finding of the current study we can conclude that there were a significant difference between the both groups in all studied parameters (the WOMAC, functional level, quadriceps muscle strength and the joint proprioception). Also this study did not support the dependency on radiological findings in management of knee OA as the radiological features did not necessarily indicate the level of structural damage of patients with knee OA and we should consider the clinical features in our treatment plan.

Keywords: joint position sense, peak torque, proprioception, radiological knee osteoarthritis

Procedia PDF Downloads 274
213 Challenges in Early Diagnosis of Enlarged Vestibular Aqueduct (EVA) in Pediatric Population: A Single Case Report

Authors: Asha Manoharan, Sooraj A. O, Anju K. G

Abstract:

Enlarged vestibular aqueduct (EVA) refers to the presence of congenital sensorineural hearing loss with an enlarged vestibular aqueduct. The Audiological symptoms of EVA are fluctuating and progressive in nature and the diagnosis of EVAS can be confirmed only with radiological evaluation. Hence it is difficult to differentiate EVA from conditions like Meniere’s disease, semi-circular dehiscence, etc based on audiological findings alone. EVA in adults is easy to identify due to distinct vestibular symptoms. In children, EVA can remain either unidentified or misdiagnosed until the vestibular symptoms are evident. Motor developmental delay, especially the ones involving a change of body alignment, has been reported in the pediatric population with EVA. So, it should be made mandatory to recommend radiological evaluation in young children with fluctuating hearing loss reporting with motor developmental delay. This single case study of a baby with Enlarged Vestibular Aqueduct (EVA) primarily aimed to address the following: a) Challenges while diagnosing young patients with EVA and fluctuating hearing loss, b) Importance of radiological evaluation in audiological diagnosis in the pediatric population, c) Need for regular monitoring of hearing, hearing aid performance, and cochlear implant mapping closely for potential fluctuations in such populations, d) Importance of reviewing developmental, language milestones in very young children with fluctuating hearing loss.

Keywords: enlarged vestibular aqueduct (EVA), motor delay, radiological evaluation, fluctuating hearing loss, cochlear implant

Procedia PDF Downloads 125
212 Pres Syndrome in Pregnancy: A Case Series of Five Cases

Authors: Vaibhavi Birle

Abstract:

Posterior reversible encephalopathy syndrome is a rare clinic-radiological syndrome associated with acute changes in blood pressure during pregnancy. It is characterized symptomatically by headache, seizures, altered mental status, and visual blurring with radiological changes of white matter (vasogenic oedema) affecting the posterior occipital and parietal lobes of the brain. It is being increasingly recognized due to increased institutional deliveries and advances in imaging particularly magnetic resonance imaging (MRI). In spite of the increasing diagnosis the prediction of PRES and patient factors affecting susceptibility is still not clear. Hence, we conducted the retrospective study to analyse the factors associated with PRES at our tertiary centre.

Keywords: pres syndrome, eclampsia, maternal outcome, fetal outcome

Procedia PDF Downloads 124
211 Utility of CT Perfusion Imaging for Diagnosis and Management of Delayed Cerebral Ischaemia Following Subarachnoid Haemorrhage

Authors: Abdalla Mansour, Dan Brown, Adel Helmy, Rikin Trivedi, Mathew Guilfoyle

Abstract:

Introduction: Diagnosing delayed cerebral ischaemia (DCI) following aneurysmal subarachnoid haemorrhage (SAH) can be challenging, particularly in poor-grade patients. Objectives: This study sought to assess the value of routine CTP in identifying (or excluding) DCI and in guiding management. Methods: Eight-year retrospective neuroimaging study at a large UK neurosurgical centre. Subjects included a random sample of adult patients with confirmed aneurysmal SAH that had a CTP scan during their inpatient stay, over a 8-year period (May 2014 - May 2022). Data collected through electronic patient record and PACS. Variables included age, WFNS scale, aneurysm site, treatment, the timing of CTP, radiologist report, and DCI management. Results: Over eight years, 916 patients were treated for aneurysmal SAH; this study focused on 466 patients that were randomly selected. Of this sample, 181 (38.84%) had one or more CTP scans following brain aneurysm treatment (Total 318). The first CTP scan in each patient was performed at 1-20 days following ictus (median 4 days). There was radiological evidence of DCI in 83, and no reversible ischaemia was found in 80. Findings were equivocal in the remaining 18. Of the 103 patients treated with clipping, 49 had DCI radiological evidence, in comparison to 31 of 69 patients treated with endovascular embolization. The remaining 9 patients are either unsecured aneurysms or non-aneurysmal SAH. Of the patients with radiological evidence of DCI, 65 had a treatment change following the CTP directed at improving cerebral perfusion. In contrast, treatment was not changed for (61) patients without radiological evidence of DCI. Conclusion: CTP is a useful adjunct to clinical assessment in the diagnosis of DCI and is helpful in identifying patients that may benefit from intensive therapy and those in whom it is unlikely to be effective.

Keywords: SAH, vasospasm, aneurysm, delayed cerebral ischemia

Procedia PDF Downloads 40
210 Adobe Attenuation Coefficient Determination and Its Comparison with Other Shielding Materials for Energies Found in Common X-Rays Procedures

Authors: Camarena Rodriguez C. S., Portocarrero Bonifaz A., Palma Esparza R., Romero Carlos N. A.

Abstract:

Adobe is a construction material that fulfills the same function as a conventional brick. Widely used since ancient times, it is present in an appreciable percentage of buildings in Latin America. Adobe is a mixture of clay and sand. The interest in the study of the properties of this material arises due to its presence in the infrastructure of hospital´s radiological services, located in places with low economic resources, for the attenuation of radiation. Some materials such as lead and concrete are the most used for shielding and are widely studied in the literature. The present study will determine the mass attenuation coefficient of Adobe. The minimum required thicknesses for the primary and secondary barriers will be estimated for the shielding of radiological facilities where conventional and dental X-rays are performed. For the experimental procedure, an X-ray source emitted direct radiation towards different thicknesses of an Adobe barrier, and a detector was placed on the other side. For this purpose, an UNFORS Xi solid state detector was used, which collected information on the difference of radiation intensity. The initial parameters of the exposure started at 45 kV; and then the tube tension was varied in increments of 5 kV, reaching a maximum of 125 kV. The X-Ray tube was positioned at a distance of 0.5 m from the surface of the Adobe bricks, and the collimation of the radiation beam was set for an area of 0.15 m x 0.15 m. Finally, mathematical methods were applied to determine the mass attenuation coefficient for different energy ranges. In conclusion, the mass attenuation coefficient for Adobe was determined and the approximate thicknesses of the most common Adobe barriers in the hospital buildings were calculated for their later application in the radiological protection.

Keywords: Adobe, attenuation coefficient, radiological protection, shielding, x-rays

Procedia PDF Downloads 133
209 Evaluation of the Risk Factors on the Incidence of Adjacent Segment Degeneration After Anterior Neck Discectomy and Fusion

Authors: Sayyed Mostafa Ahmadi, Neda Raeesi

Abstract:

Background and Objectives: Cervical spondylosis is a common problem that affects the adult spine and is the most common cause of radiculopathy and myelopathy in older patients. Anterior discectomy and fusion is a well-known technique in degenerative cervical disc disease. However, one of the late undesirable complications is adjacent disc degeneration, which affects about 91% of patients in ten years. Many factors can be effective in causing this complication, but some are still debatable. Discovering these risk factors and eliminating them can improve the quality of life. Methods: This is a retrospective cohort study. All patients who underwent anterior discectomy and fusion surgery in the neurosurgery ward of Imam Khomeini Hospital between 2013 and 2016 were evaluated. Their demographic information was collected. All patients were visited and examined for radiculopathy, myelopathy, and muscular force. At the same visit, all patients were asked to have a facelift, and neck profile, as well as a neck MRI(General Tesla 3). Preoperative graphs were used to measure the diameter of the cervical canal(Pavlov ratio) and to evaluate sagittal alignment(Cobb Angle). Preoperative MRI of patients was reviewed for anterior and posterior longitudinal ligament calcification. Result: In this study, 57 patients were studied. The mean age of patients was 50.63 years, and 49.1% were male. Only 3.5% of patients had anterior and posterior longitudinal ligament calcification. Symptomatic ASD was observed in 26.6%. The X-rays and MRIs showed evidence of 80.7% radiological ASD. Among patients who underwent one-level surgery, 20% had symptomatic ASD, but among patients who underwent two-level surgery, the rate of ASD was 50%.In other words, the higher the number of surfaces that are operated and fused, the higher the probability of symptomatic ASD(P-value <0.05). The X-rays and MRIs showed 80.7% of radiological ASD. Among patients who underwent surgery at one level, 78% had radiological ASD, and this number was 92% among patients who underwent two-level surgery(P-value> 0.05). Demographic variables such as age, sex, height, weight, and BMI did not have a significant effect on the incidence of radiological ASD(P-value> 0.05), but sex and height were two influential factors on symptomatic ASD(P-value <0.05). Other related variables such as family history, smoking and exercise also have no significant effect(P-value> 0.05). Radiographic variables such as Pavlov ratio and sagittal alignment were also unaffected by the incidence of radiological and symptomatic ASD(P-value> 0.05). The number of surgical surfaces and the incidence of anterior and posterior longitudinal ligament calcification before surgery also had no statistically significant effect(P-value> 0.05). In the study of the ability of the neck to move in different directions, none of these variables are statistically significant in the two groups with radiological and symptomatic ASD and the non-affected group(P-value> 0.05). Conclusion: According to the findings of this study, this disease is considered to be a multifactorial disease. The incidence of radiological ASD is much higher than symptomatic ASD (80.7% vs. 26.3%) and sex, height and number of fused surfaces are the only factors influencing the incidence of symptomatic ASD and no variable influences radiological ASD.

Keywords: risk factors, anterior neck disectomy and fusion, adjucent segment degeneration, complication

Procedia PDF Downloads 25
208 Managing Pseudoangiomatous Stromal Hyperplasia Appropriately and Safely: A Retrospective Case Series Review

Authors: C. M. Williams, R. English, P. King, I. M. Brown

Abstract:

Introduction: Pseudoangiomatous Stromal Hyperplasia (PASH) is a benign fibrous proliferation of breast stroma affecting predominantly premenopausal women with no significant increased risk of breast cancer. Informal recommendations for management have continued to evolve over recent years from surgical excision to observation, although there are no specific national guidelines. This study assesses the safety of a non-surgical approach to PASH management by review of cases at a single centre. Methods: Retrospective case series review (January 2011 – August 2016) was conducted on consecutive PASH cases. Diagnostic classification (clinical, radiological and histological), management outcomes, and breast cancer incidence were recorded. Results: 43 patients were followed up for median of 25 months (3-64) with 75% symptomatic at presentation. 12% of cases (n=5) had a radiological score (BIRADS MMG or US) ≥ 4 of which 3 were confirmed malignant. One further malignancy was detected and proven radiologically occult and contralateral. No patients were diagnosed with a malignancy during follow-up. Treatment evolved from 67% surgical in 2011 to 33% in 2016. Conclusions: The management of PASH has transitioned in line with other published experience. The preliminary findings suggest this appears safe with no evidence of missed malignancies; however, longer follow up is required to confirm long-term safety. Recommendations: PASH with suspicious radiological findings ( ≥ U4/R4) warrants multidisciplinary discussion for excision. In the absence of histological or radiological suspicion of malignancy, PASH can be safely managed without surgery.

Keywords: benign breast disease, conservative management, malignancy, pseudoangiomatous stromal hyperplasia, surgical excision

Procedia PDF Downloads 111
207 Effect of Retained Posterior Horn of Medial Meniscus on Functional Outcome of ACL Reconstructed Knees

Authors: Kevin Syam, Devendra K. Chauhan, Mandeep Singh Dhillon

Abstract:

Background: The posterior horn of medial meniscus (PHMM) is a secondary stabilizer against anterior translation of tibia. Cadaveric studies have revealed increased strain on the ACL graft and greater instrumented laxity in Posterior horn deficient knees. Clinical studies have shown higher prevalence of radiological OA after ACL reconstruction combined with menisectomy. However, functional outcomes in ACL reconstructed knee in the absence of Posterior horn is less discussed, and specific role of posterior horn is ill-documented. This study evaluated functional and radiological outcomes in posterior horn preserved and posterior horn sacrificed ACL reconstructed knees. Materials: Of the 457 patients who had ACL reconstruction done over a 6 year period, 77 cases with minimum follow up of 18 months were included in the study after strict exclusion criteria (associated lateral meniscus injury, other ligamentous injuries, significant cartilage degeneration, repeat injury and contralateral knee injuries were excluded). 41 patients with intact menisci were compared with 36 patients with absent posterior horn of medial meniscus. Radiological and clinical tests for instability were conducted, and knees were evaluated using subjective International Knee Documentation Committee (IKDC) score and the Orthopadische Arbeitsgruppe Knie score (OAK). Results: We found a trend towards significantly better overall outcome (OAK) in cases with intact PHMM at average follow-up of 43.03 months (p value 0.082). Cases with intact PHMM had significantly better objective stability (p value 0.004). No significant differences were noted in the subjective IKDC score (p value 0.526) and the functional OAK outcome (category D) (p value 0.363). More cases with absent posterior horn had evidence of radiological OA (p value 0.022) even at mid-term follow-up. Conclusion: Even though the overall OAK and subjective IKDC scores did not show significant difference between the two subsets, the poorer outcomes in terms of objective stability and radiological OA noted in the absence of PHMM, indicates the importance of preserving this important part of the meniscus.

Keywords: ACL, functional outcome, knee, posterior of medial meniscus

Procedia PDF Downloads 339
206 Simulation of X-Ray Tissue Contrast and Dose Optimisation in Radiological Physics to Improve Medical Imaging Students’ Skills

Authors: Peter J. Riley

Abstract:

Medical Imaging students must understand the roles of Photo-electric Absorption (PE) and Compton Scatter (CS) interactions in patients to enable optimal X-ray imaging in clinical practice. A simulator has been developed that shows relative interaction probabilities, color bars for patient dose from PE, % penetration to the detector, and obscuring CS as Peak Kilovoltage (kVp) changes. Additionally, an anthropomorphic chest X-ray image shows the relative tissue contrasts and overlying CS-fog at that kVp, which determine the detectability of a lesion in the image. A series of interactive exercises with MCQs evaluate the student's understanding; the simulation has improved student perception of the need to acquire "sufficient" rather than maximal contrast to enable patient dose reduction at higher kVp.

Keywords: patient dose optimization, radiological physics, simulation, tissue contrast

Procedia PDF Downloads 56
205 Study of Radiological and Chemical Effects of Uranium in Ground Water of SW and NE Punjab, India

Authors: Komal Saini, S. K. Sahoo, B. S. Bajwa

Abstract:

The Laser Fluorimetery Technique has been used for the microanalysis of uranium content in water samples collected from different sources like the hand pumps, tube wells in the drinking water samples of SW & NE Punjab, India. The geographic location of the study region in NE Punjab is between latitude 31.21º- 32.05º N and longitude 75.60º-76.14º E and for SW Punjab is between latitude 29.66º-30.48º N and longitude 74.69º-75.54º E. The purpose of this study was mainly to investigate the uranium concentration levels of ground water being used for drinking purposes and to determine its health effects, if any, to the local population of these regions. In the present study 131 samples of drinking water collected from different villages of SW and 95 samples from NE, Punjab state, India have been analyzed for chemical and radiological toxicity. In the present investigation, uranium content in water samples of SW Punjab ranges from 0.13 to 908 μgL−1 with an average of 82.1 μgL−1 whereas in samples collected from NE- Punjab, it ranges from 0 to 28.2 μgL−1 with an average of 4.84 μgL−1. Thus, revealing that in the SW- Punjab 54 % of drinking water samples have uranium concentration higher than international recommended limit of 30 µgl-1 (WHO, 2011) while 35 % of samples exceeds the threshold of 60 µgl-1 recommended by our national regulatory authority of Atomic Energy Regulatory Board (AERB), Department of Atomic Energy, India, 2004. On the other hand in the NE-Punjab region, none of the observed water sample has uranium content above the national/international recommendations. The observed radiological risk in terms of excess cancer risk ranges from 3.64x10-7 to 2.54x10-3 for SW-Punjab, whereas for NE region it ranges from 0 to 7.89x10-5. The chemical toxic effect in terms of Life-time average Daily Dose (LDD) and Hazard Quotient (HQ) have also been calculated. The LDD for SW-Punjab varies from 0.0098 to 68.46 with an average of 6.18 µg/ kg/day whereas for NE region it varies from 0 to 2.13 with average 0.365 µg/ kg/day, thus indicating presence of chemical toxicity in SW Punjab as 35% of the observed samples in the SW Punjab are above the recommendation limit of 4.53 µg/ kg/day given by AERB for 60 µgl-1 of uranium. Maximum & Minimum values for hazard quotient for SW Punjab is 0.002 & 15.11 with average 1.36 which is considerably high as compared to safe limit i.e. 1. But for NE Punjab HQ varies from 0 to 0.47. The possible sources of high uranium observed in the SW- Punjab will also be discussed.

Keywords: uranium, groundwater, radiological and chemical toxicity, Punjab, India

Procedia PDF Downloads 353
204 Radiological Hazard Assessments and Control of Radionuclides Emitted from Building Materials in Kuwait Using Expert Systems

Authors: Abdulla Almulla, Wafaa Mahdi

Abstract:

Building materials can make a significant contribution to the level of natural radioactivity in closed dwelling areas. Therefore, developing an expert system for monitoring the activity concentrations (ACs) of naturally occurring radioactive materials (NORMs) existing in building materials is useful for limiting the population’s exposure to gamma radiation emitted from those materials. The present work not only is aimed at examining the indoor radon concentration emitted by the building materials that are originated from various countries but are commercially available in Kuwait, but also is aimed at developing an expert system for monitoring the radiation emitted from these materials and classifying it as normal (acceptable) or dangerous (unacceptable). This system makes it possible to always monitor any radiological risks to human health. When detecting high doses of radiation, the system gives warning messages.

Keywords: building materials, NORMs, HNBRA, radionuclides, activity concentrations, expert systems

Procedia PDF Downloads 129
203 In-Situ Determination of Radioactivity Levels and Radiological Hazards in and around the Gold Mine Tailings of the West Rand Area, South Africa

Authors: Paballo M. Moshupya, Tamiru A. Abiye, Ian Korir

Abstract:

Mining and processing of naturally occurring radioactive materials could result in elevated levels of natural radionuclides in the environment. The aim of this study was to evaluate the radioactivity levels on a large scale in the West Rand District in South Africa, which is dominated by abandoned gold mine tailings and the consequential radiological exposures to members of the public. The activity concentrations of ²³⁸U, ²³²Th and 40K in mine tailings, soil and rocks were assessed using the BGO Super-Spec (RS-230) gamma spectrometer. The measured activity concentrations for ²³⁸U, ²³²Th and 40K in the studied mine tailings were found to range from 209.95 to 2578.68 Bq/kg, 19.49 to 108.00 Bq/kg and 31.30 to 626.00 Bq/kg, respectively. In surface soils, the overall average activity concentrations were found to be 59.15 Bq/kg, 34.91 and 245.64 Bq/kg for 238U, ²³²Th and 40K, respectively. For the rock samples analyzed, the mean activity concentrations were 32.97 Bq/kg, 32.26 Bq/kg and 351.52 Bg/kg for ²³⁸U, ²³²Th and 40K, respectively. High radioactivity levels were found in mine tailings, with ²³⁸U contributing significantly to the overall activity concentration. The external gamma radiation received from surface soil in the area is generally low, with an average of 0.07 mSv/y. The highest annual effective doses were estimated from the tailings dams and the levels varied between 0.14 mSv/y and 1.09 mSv/y, with an average of 0.51 mSv/y. In certain locations, the recommended dose constraint of 0.25 mSv/y from a single source to the average member of the public within the exposed population was exceeded, indicating the need for further monitoring and regulatory control measures specific to these areas to ensure the protection of resident members of the public.

Keywords: activity concentration, gold mine tailings, in-situ gamma spectrometry, radiological exposures

Procedia PDF Downloads 102
202 Brain Bleeding Venous Malformation in the Computed Tomography Emergency Department

Authors: Angelis P. Barlampas

Abstract:

The aim of this work is to denote that during an emergency state, an examination study may not be accomplished by state-of-the-art of imaging and, therefore, cannot obviously reveal all the existing findings. But, such a situation may have disastrous consequences for the patient. When interpreting radiological images, one must try to be as meticulous as possible, especially if the patient has alerting clinical symptoms. A case may be missed because its findings are not so obvious in rapid uncompleted radiological imaging. A thirty-seven years old female patient visited the emergency department because of a headache and hemiparesis of her left leg. Firstly, a CT examination without contrast was done, and mild serpentinous hyperintensities were depicted at the right parietal lobe. In addition to that, there was a linear, mildly hyperattenuating structure resembling a vessel in the nearby middle line. At first, an AVM was suspected, so an MRI examination with i.v. Gd was prescribed. The patient returned a few days later, not having done the MRI and complaining of persisting symptomatology. A new CT examination without and with i.v.c administration was done that showed no hyperintensities but a type-enhancing vessel in the posterior interhemispheric fissure. The latest findings are consistent with a venous malformation with previous bleeding.

Keywords: bleeding, brain, CNS, hemorrhage, CT, venous malformation

Procedia PDF Downloads 87
201 Clinical Outcomes After Radiological Management of Varicoceles

Authors: Eric Lai, Sarah Lorger, David Eisinger, Richard Waugh

Abstract:

Introduction: Percutaneous embolization of varicoceles has shown similar outcomes to surgery. However, there are advantages of radiological intervention as patients are not exposed to general anaesthesia, experience a quicker recovery and face a lower risk of major complications. Radiological interventions are also preferable after a failed surgical approach. We evaluate clinical outcomes of percutaneous embolization at a tertiary hospital in Sydney, Australia. Methods: Retrospective case series without a control group from a single site (Royal Prince Alfred Hospital, Sydney, Australia). A data search was performed on the interventional radiology database with the word “varicocele” between February 2017 and March 2022. 62 patients were identified. Each patient file was reviewed and included in the study if they met the inclusion criteria. Results: A total of 56 patients were included. 6 patients were excluded as they did not receive intervention after the initial diagnostic venography. Technical success was 100%. Complications were seen in 3 patients (5.3%). The complications included post-procedural pain and fever, venous perforation with no clinical adverse outcome, and a mild allergic reaction to contrast. Recurrence occurred in 3 patients (5.6%), all of whom received a successful second procedure. DISCUSSION: This study demonstrates comparable rates of technical success, complication rate and recurrence to other studies in the literature. When compared to surgical outcomes, the results were also similar. The main limitation is multiple patients lack long-term follow-up beyond 1 year, resulting in potential underestimation of the recurrence rate. Conclusion: Percutaneous embolization of varicocele is a safe alternative to surgical intervention.

Keywords: varicocele, interventional radiology, urology, radiology

Procedia PDF Downloads 33
200 Clinicoradiographic Evaluation of Polymer of Injectable Platelet-Rich Fibrin (i-PRF) and Hydroxyapatite as Bone Graft Substitute in Maxillomandibular Bony Defects: A Double-Blinded Randomized Control Trial

Authors: Naqoosh Haidry

Abstract:

Objective & Goal: Enucleation of the maxillomandibular cysts will lead to the creation of post-surgical bone defects which may take more than a year for complete bone healing. The use of bone grafts is common to aid bone regeneration in large defects. The study aimed to evaluate the healing and bone formation capabilities of polymer of injectable platelet fibrin (i-PRF) and hydroxyapatite (HA) as bone graft substitute in maxilla-mandibular postsurgical defects compared to hydroxyapatite alone. The primary objective was to find out the clinical and radiological assessment of healing postoperatively and compare the outcome of both groups. Material and Methods: After surgical enucleation of 19 maxillomandibular cysts/tumors, either HA or HA+ i-PRF graft was adapted to the defect. Clinical outcome variables such as pain (VAS score), edema, and mucosal color were evaluated on postoperative days 01, 03, and 07 while radiological outcome variables such as volume of defect (cc), density of new bone (HU) on computed tomography were evaluated at 2nd and 4th month. The results obtained were tabulated and compared with the inferential analysis. Results: Clinical parameters seem to be better in the HA + i-PRF group, but the result was non-significant. Radiologically, the mean healing ratios were significantly greater in the HA + i-PRF group (63.5 ± 2.34 at 2nd month, 90.3 ± 7.32 at 4th month) compared to the HA group (57.2 ± 5.21at 2nd month, 80.8 ± 5.33 at 4th month). When comparing the mean density of new bone, there was a statistically significant difference with a mean difference of 95.2 HU more in the HA + i-PRF (623 HU ± 42.9) compared to the HA group (528 HU ± 96.5) in 2nd month. Conclusion: The polymer of i-PRF and HA prepared as the sticky bone yields faster and better bone healing in post-enucleation maxillomandibular bony defects as compared to hydroxyapatite alone based on radiological findings till four months.

Keywords: bone defect, density of new bone, hydroxyapatite, injectable platelet rich fibrin, maxillomandibular cysts, surgical defect

Procedia PDF Downloads 19
199 Dose Measurement in Veterinary Radiology Using Thermoluminescent Dosimeter

Authors: Ava Zarif Sanayei, Sedigheh Sina

Abstract:

Radiological protection for plants and animals is an area of regulatory importance. Acute doses of 0.1 Gy/d (10 rad/d) or below are highly unlikely to produce permanent, measurable negative effects on populations or communities of plants or animals. The advancement of radio diagnostics for domestic animals, particularly dogs and cats, has gained popularity in veterinary medicine. As pets are considered to be members of the family worldwide, they are entitled to the same care and protection. It is important to have a system of radiological protection for nonhuman organisms that complies with the focus on human health as outlined in ICRP publication 19. The present study attempts to assess surface-skin entrance doses in small pets undergoing abdominal radio diagnostic procedures utilizing a direct measurements technique with a thermoluminescent dosimeter. These measurements allow the determination of the entrance skin dose (ESD) by calculating the amount of radiation absorbed by the skin during exposure. A group of Thirty TLD-100 dosimeters produced by Harshaw Company, each with a repeatability greater than 95% and calibration using ¹³⁷Cs gamma source, were utilized to measure doses to ten small pets, including cats and dogs in the radiological department in a veterinary clinic in Shiraz, Iran. Radiological procedures were performed using a portable imaging unit (Philips Super M100, Philips Medical System, Germany) to acquire images of the abdomen; ten exams of abdomen images of different pets were monitored, measuring the thicknesses of the two projections (lateral and ventrodorsal) and the distance of the X-ray source from the surface of each pet during the exams. A group of two dosimeters was used for each pet which has been stacked on their skin on the abdomen region. The outcome of this study involved medical procedures with the same kVp, mAs, and nearly identical positions for different diagnostic X-ray procedures executed over a period of two months. The result showed the mean ESD value was 260.34±50.06 µGy due to the approximate size of pets. Based on the results, the ESD value is associated with animal size, and larger animals have higher values. If a procedure doesn't require repetition, the dose can be optimized. For smaller animals, the main challenge in veterinary radiology is the dose increase caused by repetitions, which is most noticeable in the ventro-dorsal position due to the difficulty in immobilizing the animal.

Keywords: direct dose measuring, dosimetry, radiation protection, veterinary medicine

Procedia PDF Downloads 34
198 Guidelines to Designing Generic Protocol for Responding to Chemical, Biological, Radiological and Nuclear Incidents

Authors: Mohammad H. Yarmohammadian, Mehdi Nasr Isfahani, Elham Anbari

Abstract:

Introduction: The awareness of using chemical, biological, and nuclear agents in everyday industrial and non-industrial incidents has increased recently; release of these materials can be accidental or intentional. Since hospitals are the forefronts of confronting Chemical, Biological, Radiological and Nuclear( CBRN) incidents, the goal of the present research was to provide a generic protocol for CBRN incidents through a comparative review of CBRN protocols and guidelines of different countries and reviewing various books, handbooks and papers. Method: The integrative approach or research synthesis was adopted in this study. First a simple narrative review of programs, books, handbooks, and papers about response to CBRN incidents in different countries was carried out. Then the most important and functional information was discussed in the form of a generic protocol in focus group sessions and subsequently confirmed. Results: Findings indicated that most of the countries had various protocols, guidelines, and handbooks for hazardous materials or CBRN incidents. The final outcome of the research synthesis was a 50 page generic protocol whose main topics included introduction, definition and classification of CBRN agents, four major phases of incident and disaster management cycle, hospital response management plan, equipment, and recommended supplies and antidotes for decontamination (radiological/nuclear, chemical, biological); each of these also had subtopics. Conclusion: In the majority of international protocols, guidelines, handbooks and also international and Iranian books and papers, there is an emphasis on the importance of incident command system, determining the safety degree of decontamination zones, maps of decontamination zones, decontamination process, triage classifications, personal protective equipment, and supplies and antidotes for decontamination; these are the least requirements for such incidents and also consistent with the provided generic protocol.

Keywords: hospital, CBRN, decontamination, generic protocol, CBRN Incidents

Procedia PDF Downloads 271
197 A Case of Apocrine Sweat Gland Adenocarcinoma in a Tabby Cat

Authors: Funda Terzi, Elif Dogan, Ayse B. Kapcak

Abstract:

In this report, clinical, radiological, macroscopic, and histopathological findings of apocrine sweat gland adenocarcinoma are presented in a 13-year-old male tabby cat. In clinical examination, soft tissue masses were detected in the caudal abdomen and left tuber coxae. On radiological examination, subcutaneous masses with soft tissue contrast appearance were detected, and the masses were surgically removed under general anesthesia. The sizes of the masses were approximately 2x2x3 cm in the caudal abdomen and approximately 1x1x2 cm in the tuber coxae region. The cross-section of the mass was whitish-yellow in color. After the masses were fixed in 10% formaldehyde solution, a routine histopathology procedure was applied. In histopathological examination, apocrine sweat glands in a cystic structure and extensions from the center of the cyst to the lumen were determined, and anisonucleosis, anisocytosis, and anaplastic cells with giant nuclei were observed in the epithelial cells of the gland facing the lumen. A diagnosis of papillary-cystic type apocrine sweat gland adenocarcinoma was made with these findings.

Keywords: apocrine sweat gland, carcinoma, cat, histopathology

Procedia PDF Downloads 137
196 Evaluation of Radiological Health Danger Indices Arising from Diagnostic X-Ray Rooms

Authors: Jessica Chukwuyem Molua, Collins O Molua

Abstract:

The effective dose of selected health care workers who are constantly exposed to X-ray radiation was measured using thermoluminescence dosimeters (TLD) placed over the lead apron at the chest region in all categories of medical personnel investigated. To measure radiation in all the selected hospitals to ascertain the exposure of x-ray machines at exactly 1m from the primary source. The work was carried out within a year in each of the selected centers. The personnel examination records containing the type of examination each day, peak tube voltage, tube current, and exposure time, including the actual number of films used, were obtained. A total of 40personel were examined in government hospital Agbor, 21 in central hospital Owa Alero and 18 in Okonye hospital The method used here has also been used by other researchers. Findings showed that the results obtained from the three hospitals investigated in this work were found to conform with the recommendations of the National Commission on radiological and protection {NCRP} 70 and 116 protocols. The Radiologist in the three study areas has the highest dose level, but of particular note is the dosage of the radiologist in Okonye hospital. This, as observed, is because the protective shielding parameters were inadequate and this could result in severe health consequences over time.

Keywords: radiology, health, Agbor, Owa

Procedia PDF Downloads 62
195 Tuberculous Osteomyelitis Mimicking Tumours and Tumour-Like Lesions of Bone: Clinico-Radiologic Study of 22 Patients

Authors: Parveen Kundu, Zile Singh, Kunika Kundu, Swaran Kaur

Abstract:

Context: Tuberculous osteomyelitis is a relatively uncommon condition that can present with various clinical and radiological features, often mimicking bone tumors or tumor-like lesions. In endemic countries like India, tuberculosis should be considered as a potential differential diagnosis for lytic bone lesions. This study aimed to highlight the different presentations of tuberculosis that can mimic tumors or tumor-like lesions in bone and emphasize the successful outcome of antitubercular therapy (ATT) in treating these cases. Research Aim: The main objective of this research was to explore the varied presentations of tuberculosis that mimic bone tumors or tumor-like lesions both clinically and radiologically, focusing on different bones. The study aimed to raise awareness among clinicians about this possibility and highlight the importance of histopathological confirmation before initiating treatment for lytic bone lesions. Methodology: This study utilized a retrospective review of 22 patients with suspected lytic bone lesions, who were subsequently diagnosed with tuberculous osteomyelitis through histopathological examination. The cases were collected over a period of ten years. Eleven cases required curettage for extensive lesions with sequestrations, while all 22 patients received 12 months of antitubercular therapy. Findings: The study included 14 male and 8 female patients, ranging in age from 3 to 61 years, with an average age of 22.05. The clinical and radiological presentations varied, with examples including bone cysts in the metaphyseal area of long bones, lesions resembling chondroblastomas, giant cell tumors, and osteoid osteoma, as well as multifocal lytic lesions resembling metastasis or multiple myeloma. One patient had lesions in both the clavicle and hand. Lesions mimicking chondromas were also observed in the phalanges of the hand and foot metatarsal. All patients showed resolution of the lesions and no residual disability following ATT. Theoretical Importance: This study highlights the importance of considering tuberculosis as a potential differential diagnosis for lytic bone lesions, particularly in endemic regions. It emphasizes the need for histopathological confirmation to accurately diagnose tuberculous osteomyelitis, as this is considered the gold standard. Data Collection and Analysis Procedures: Data for this study were collected retrospectively from medical records and radiological images of the 22 patients. The cases were analyzed based on clinical presentation, radiological findings, and histopathological confirmation. The outcomes of antitubercular therapy were also assessed. The data were summarized and presented descriptively. Question Addressed: This study aimed to address the question of how tuberculosis can mimic different bone tumors and tumor-like lesions clinically and radiologically. It also aimed to assess the successful outcome of antitubercular therapy in treating these cases. Conclusion: Tuberculous osteomyelitis can present with varied clinical and radiological features, often mimicking bone tumors or tumor-like lesions. Clinicians should consider tuberculosis as a potential diagnosis for lytic bone lesions, especially in endemic areas. Histopathological confirmation is essential for accurate diagnosis. Antitubercular therapy is an effective treatment for tuberculous osteomyelitis, leading to the resolution of the lesions with no residual disability.

Keywords: tuberculosis, tumor, curettage, bone

Procedia PDF Downloads 52
194 Nuclear Terrorism Decision Making: A Comparative Study of South Asian Nuclear Weapons States

Authors: Muhammad Jawad Hashmi

Abstract:

The idea of nuclear terrorism is as old as nuclear weapons but the global concerns of likelihood of nuclear terrorism are uncertain. Post 9/11 trends manifest that terrorists are believers of massive causalities. Innovation in terrorist’s tactics, sophisticated weaponry, vulnerability, theft and smuggling of nuclear/radiological material, connections between terrorists, black market and rough regimes are signaling seriousness of upcoming challenges as well as global trends of “terror-transnationalism.” Furthermore, the International-Atomic-Energy-Agency’s database recorded 2734 incidents regarding misuse, unauthorized possession, trafficking of nuclear material etc. Since, this data also includes incidents from south Asia, so, there is every possibility to claim that such illicit activities may increase in future, mainly due to expansion of nuclear industry in South Asia. Moreover, due to such mishaps the region is vulnerable to threats of nuclear terrorism. This is also a reason that the region is in limelight along with issues such as rapidly growing nuclear arsenals, nuclear safety and security, terrorism and political instability. With this backdrop, this study is aimed to investigate the prevailing threats and challenges in South Asia vis a vis nuclear safety and security. A comparative analysis of the overall capabilities would be done to identify the areas of cooperation to eliminate the probability of nuclear/radiological terrorism in the region.

Keywords: nuclear terrorism, safety, security, South Asia, india, Pakistan

Procedia PDF Downloads 330
193 Radiation Protection Study for the Assessment of Mixed Fields Ionizing Radiation

Authors: Avram Irina, Coiciu Eugenia-Mihaela, Popovici Mara-Georgiana, Mitu Iani Octavian

Abstract:

ELI-NP stands as a cutting-edge facility globally, hosting unique radiological setups. It conducts experiments leveraging high-power lasers capable of producing extremely brief 10 PW pulses on two fronts. Moreover, it houses an exceptional gamma beam system with distinctive spectral characteristics. The facility hosts various experiments across designated experimental areas, encompassing ultra-short high-power laser tests, high-intensity gamma beam trials, and combined experiments utilizing both setups. The facility hosts a dosimetry laboratory, which recently obtained accreditation, where the radiation safety group employs a host of different types of detectors for monitoring the personnel, environment, and public exposure to ionizing radiation generated in experiments performed. ELI-NP's design was shaped by radiological protection assessments conducted through Monte Carlo simulations. The poster exemplifies an assessment conducted using the FLUKA code in an experimental area where a high-power laser system is implemented, and the future diagnostic system for variable energy gamma beams will soon be operational.

Keywords: radiation protection, Monte Carlo simulation, FLUKA, dosimetry

Procedia PDF Downloads 35
192 Correlation Between Different Radiological Findings and Histopathological diagnosis of Breast Diseases: Retrospective Review Conducted Over Sixth Years in King Fahad University Hospital in Eastern Province, Saudi Arabia

Authors: Sadeem Aljamaan, Reem Hariri, Rahaf Alghamdi, Batool Alotaibi, Batool Alsenan, Lama Althunayyan, Areej Alnemer

Abstract:

The aim of this study is to correlate between radiological findings and histopathological results in regard to the breast imaging-reporting and data system scores, size of breast masses, molecular subtypes and suspicious radiological features, as well as to assess the concordance rate in histological grade between core biopsy and surgical excision among breast cancer patients, followed by analyzing the change of concordance rate in relation to neoadjuvant chemotherapy in a Saudi population. A retrospective review was conducted over 6-year period (2017-2022) on all breast core biopsies of women preceded by radiological investigation. Chi-squared test (χ2) was performed on qualitative data, the Mann-Whitney test for quantitative non-parametric variables, and the Kappa test for grade agreement. A total of 641 cases were included. Ultrasound, mammography, and magnetic resonance imaging demonstrated diagnostic accuracies of 85%, 77.9% and 86.9%; respectively. magnetic resonance imaging manifested the highest sensitivity (72.2%), and the lowest was for ultrasound (61%). Concordance in tumor size with final excisions was best in magnetic resonance imaging, while mammography demonstrated a higher tendency of overestimation (41.9%), and ultrasound showed the highest underestimation (67.7%). The association between basal-like molecular subtypes and the breast imaging-reporting and data system score 5 classifications was statistically significant only for magnetic resonance imaging (p=0.04). Luminal subtypes demonstrated a significantly higher percentage of speculation in mammography. Breast imaging-reporting and data system score 4 manifested a substantial number of benign pathologies in all the 3 modalities. A fair concordance rate (k= 0.212 & 0.379) was demonstrated between excision and the preceding core biopsy grading with and without neoadjuvant therapy, respectively. The results demonstrated a down-grading in cases post-neoadjuvant therapy. In cases who did not receive neoadjuvant therapy, underestimation of tumor grade in biopsy was evident. In summary, magnetic resonance imaging had the highest sensitivity, specificity, positive predictive value and accuracy of both diagnosis and estimation of tumor size. Mammography demonstrated better sensitivity than ultrasound and had the highest negative predictive value, but ultrasound had better specificity, positive predictive value and accuracy. Therefore, the combination of different modalities is advantageous. The concordance rate of core biopsy grading with excision was not impacted by neoadjuvant therapy.

Keywords: breast cancer, mammography, MRI, neoadjuvant, pathology, US

Procedia PDF Downloads 52
191 Toxic Metal and Radiological Risk Assessment of Soil, Water and Vegetables around a Gold Mine Turned Residential Area in Mokuro Area of Ile-Ife, Osun State Nigeria: An Implications for Human Health

Authors: Grace O. Akinlade, Danjuma D. Maza, Oluwakemi O. Olawolu, Delight O. Babalola, John A. O. Oyekunle, Joshua O. Ojo

Abstract:

The Mokuro area of Ile-Ife, South West Nigeria, was well known for gold mining in the past (about twenty years ago). However, the place has since been reclaimed and converted to residential area without any environmental risk assessment of the impact of the mining tailings on the environment. Soil, water, and plant samples were collected from 4 different locations around the mine-turned-residential area. Soil samples were pulverized and sieved into finer particles, while the plant samples were dried and pulverized. All the samples were digested and analyzed for As, Pb, Cd, and Zn using atomic absorption spectroscopy (AAS). From the analysis results, the hazard index (HI) was then calculated for the metals. The soil and plant samples were air dried and pulverized, then weighed, after which the samples were packed into special and properly sealed containers to prevent radon gas leakage. After the sealing, the samples were kept for 28 days to attain secular equilibrium. The concentrations of 40K, 238U, and 232Th in the samples were measured using a cesium iodide (CsI) spectrometer and URSA software. The AAS analysis showed that As, Pb, Cd (Toxic metals), and Zn (essential trace metals) are in concentrations lower than permissible limits in plants and soil samples, while the water samples had concentrations higher than permissible limits. The calculated health indices (HI) show that HI for water is >1 and that of plants and soil is <1. Gamma spectrometry result shows high levels of activity concentrations above the recommended limits for all the soil and plant samples collected from the area. Only the water samples have activity concentrations below the recommended limit. Consequently, the absorbed dose, annual effective dose, and excess lifetime cancer risk are all above the recommended safe limit for all the samples except for water samples. In conclusion, all the samples collected from the area are either contaminated with toxic metals or they pose radiological hazards to the consumers. Further detailed study is therefore recommended in order to be able to advise the residents appropriately.

Keywords: toxic metals, gamma spectrometry, Ile-Ife, radiological hazards, gold mining

Procedia PDF Downloads 22
190 Quality Control Assessment of X-Ray Equipment in Hospitals of Katsina State, Nigeria

Authors: Aminu Yakubu Umar

Abstract:

X-ray is the major contributor to the effective dose of both the patient and the personnel. Because of the radiological risks involved, it is usually recommended that dose to patient from X-ray be kept as low as reasonably achievable (ALARA) with adequate image quality. The implementation of quality assurance in diagnostic radiology can help greatly in achieving that, as it is a technique designed to reduce X-ray doses to patients undergoing radiological examination. In this study, quality control was carried out in six hospitals, which involved KVp test, evaluation of total filtration, test for constancy of radiation output, and check for mA linearity. Equipment used include KVp meter, Rad-check meter, aluminum sheets (0.1–1.0 mm) etc. The results of this study indicate that, the age of the X-ray machines in the hospitals ranges from 3-13 years, GHI and GH2 being the oldest and FMC being the newest. In the evaluation of total filtration, the HVL of the X-ray machines in the hospitals varied, ranging from 2.3-5.2 mm. The HVL was found to be highest in AHC (5.2 mm), while it was lowest in GH3 (2.3 mm). All HVL measurements were done at 80 KVp. The variation in voltage accuracy in the hospitals ranges from 0.3%-127.5%. It was only in GH1 that the % variation was below the allowed limit. The test for constancy of radiation output showed that, the coefficient of variation ranges from 0.005–0.550. In GH3, FMC and AHC, the coefficient of linearity were less than the allowed limit, while in GH1, GH2 and GH4 the coefficient of linearity had exceeded the allowed limit. As regard to mA linearity, FMC and AHC had their coefficients of linearity as 0.12 and 0.10 respectively, which were within the accepted limit, while GH1, GH3 and GH4 had their coefficients as 0.16, 0.69 and 0.98 respectively, which exceeded the allowed limit.

Keywords: radiation, X-ray output, quality control, half-value layer, mA linearity, KVp variation

Procedia PDF Downloads 588