Search results for: ocular axial length
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3166

Search results for: ocular axial length

3166 Ocular Biometry: Common Etiologies of Difference More Than 0.33mm between Axial Lengths of the 2 Eyes

Authors: Ghandehari Motlagh, Mohammad

Abstract:

Purpose: We tried to find the most common etiologies for anisometropia in pre-op cataract cases: axial or refractive. Methods: In this cross-sectional study ,41 pre-op cataract eyes with more than 0.33 difference between axial lengths of 2 eyes were enrolled.Considered for each 1mm difference between axial lengths in long eyes( AXL more than 25):1.75-2.00 D of anisometropia, for normal eyes(AXL: 22- 25):2.50D and for short eyes (AXL less than 22):3.50-3.75 D as axial anisometropia. If there are more or lesser anisometropia, we recorded as refractive anisometropia. Results: Average of anisometropia :4.24 D, prevalence of PK or LK :1 (2.38%), kc:1(2.38%), glaucoma surgery: 1(2.38%), and pseudophakic status of the opposite eye 8(19.04%). Prevalence of axial anisometropia:21 (52.4%) and refractive anisometropia 20(47.6%).Then on basis of this study we can rely on the patient’s refraction exactly before phaco for evaluation of axial length differences between the 2 eyes, because most of the anisometropias are axial. Conclusion: In most cases, cataract does not induce significant change in refractive error (secondary myopia) and AXL difference between the 2 eyes are correlated with anisometropia.so it can be used for cataract patient’s ocular biometry evaluation. Pre-cataract refraction is a valuable variable should be measured and recorded in routin eye examination.

Keywords: ocular axial length, anisometropia, cataract, ophthalmology and optometry

Procedia PDF Downloads 355
3165 Validity of Simlified Javal’s Rule in 147 Pre-Operation Cataract Eyes

Authors: Mohammad Ghandehari Motlagh

Abstract:

Purpose: To evaluate validity of simplified Javal’s rule (Total Ast=Corneal Ast-0.50@9) in 147 pre-op cataract eyes. Methods: Due to change in lens tissue and structure in a cataract crystalline lens, we conceive the simplified javal’s rule may not be valid in cataract cases.In this cross-sectional study,147 pre-op cataract eyes without oblique astigmatism were enrolled in this study. Ocular biometry (with IOL master 500)and keratometry and refraction findings were recorded. Results: Mean age of our patients was 64.95 yrs/old (SD+_9.86) that confirms on senile cataract. Mean Axial length and average keratometry were respectively 23.86 and 44.62.Prevalence of systemic diseases diabet and high blood pressure were respectively 43 (29.25%) and 44 (29.93%)and shows importance of these diseases. The Corneal astigmatism axis is correlated with refractive astigmatism in cataract eyes (R=0.493). Simplified Javal’s rule is valid in cataract eyes (P<0.001). Conclusion: Simplified Javal’s rule is a valid formula in pre-op cataract eyes and can be used for keratometry results confirmation.

Keywords: javals rule, cataract, keratometry, ocular axial length

Procedia PDF Downloads 395
3164 Ocular Complications in Type 1 Diabetes Mellitus in Zahedan: A Tropical Region in Southeast of Iran

Authors: Mohammad Hossain Validad, Maryam Nakhaei-Moghadam, Monire Mahjoob

Abstract:

Introduction: The prevalence of type 1 diabetes is increasing worldwide, and given the role of ethnicity and race in complications of diabetes, this study was designed to evaluate the ocular complications of type 1 diabetes mellitus in Zahedan. Methods: This prospective cross-sectional study was conducted on Type 1 diabetic children that referred to Alzahra Eye Hospital. All patients had a dilated binocular indirect ophthalmoscopy using a +90 D condensing lens and slit-lamp biomicroscopy. Age, gender, onset, duration of diabetes, and HbA1c level were recorded. Results: 76 type 1 diabetes patients with an age of 11.93 ± 3.76 years participated in this study. Out of 76 patients with diabetes, 19 people (25%) had ocular complications. There was a significant difference in age (P=0.01) and disease duration (P=0.07) between the two groups with and without ocular complications. Odd ratios for ocular complications with age and duration of diabetes were 1.32 and 1.32, respectively. Conclusion: Cataract was the most common ocular complication in type 1 diabetes in Zahedan, a tropical region that was significantly related to the duration of the disease and the age of the patients.

Keywords: diabet mellitus type one, cataract, ocular complication, hemoglobin A1C

Procedia PDF Downloads 0
3163 Effect of Size and Soil Characteristic on Contribution of Side and Tip Resistance of the Drilled Shafts Axial Load Carrying Capacity

Authors: Mehrak Zargaryaeghoubi, Masood Hajali

Abstract:

Drilled shafts are the most popular of deep foundations, because they have the capability that one single shaft can easily carry the entire load of a large column from a bridge or tall building. Drilled shaft may be an economical alternative to pile foundations because a pile cap is not needed, which not only reduces that expense, but also provides a rough surface in the border of soil and concrete to carry a more axial load. Due to the larger construction sizes of drilled shafts, they have an excellent axial load carrying capacity. Part of the axial load carrying capacity of the drilled shaft is resisted by the soil below the tip of the shaft which is tip resistance and the other part is resisted by the friction developed around the drilled shaft which is side resistance. The condition at the bottom of the excavation can affect the end bearing capacity of the drilled shaft. Also, type of the soil and size of the drilled shaft can affect the frictional resistance. The main loads applied on the drilled shafts are axial compressive loads. It is important to know how many percent of the maximum applied load will be shed inside friction and how much will be transferred to the base. The axial capacity of the drilled shaft foundation is influenced by the size of the drilled shaft, and soil characteristics. In this study, the effect of the size and soil characteristic will be investigated on the contribution of side resistance and end-bearing capacity. Also, the study presents a three-dimensional finite element modeling of a drilled shaft subjected to axial load using ANSYS. The top displacement and settlement of the drilled shaft are verified with analytical results. The soil profile is considered as Table 1 and for a drilled shaft with 7 ft diameter and 95 ft length the stresses in z-direction are calculated through the length of the shaft. From the stresses in z-direction through the length of the shaft the side resistance can be calculated and with the z-direction stress at the tip, the tip resistance can be calculated. The result of the side and tip resistance for this drilled shaft are compared with the analytical results.

Keywords: Drilled Shaft Foundation, size and soil characteristic, axial load capacity, Finite Element

Procedia PDF Downloads 346
3162 A Study of Ocular Morbidity in Road Traffic Accidents

Authors: Nikhat Iqbal Tamboli

Abstract:

INTRODUCTION: road traffic accidents (RTAs) are one of the leading and common causes of ocular injuries especially in developing countries like India which are preventable with certain measures and so it is of public health importance. AIM: To study incidence and clinical presentation of ocular morbidity in road traffic accidents. METHOD: Prospective cross-sectional study was conducted on 360 patients reported in department of ophthalmology. Detailed ocular examination and relevant investigations done. RESULTS: Incidence of ocular injuries is 23%. male:female ratio is 4.5:1.Cases having Sub conjunctival haemorrhage [74].eccymosis[217]. lid lcerations [164]orbital fracture[12] corneal tear [7]corneal abrasion[2] sclera tear[6] hyphaema[4] traumatic mydriasis [7]traumatic cataract [2]vitreous haemorrhage [1]traumatic optic neuropathy[1].Maximum cases in age group 20-40 years, with two wheeler vehicles 94.7% .Under influence of alcohol 13.3%. CONCLUSION: Younger age group with male preponderance is involved in ocular trauma due to road traffic accidents .maximum cases reported are with anterior segment injuries. Alcohol and two wheeler vehicles are common risk factors. Injuries involving cornea had bad prognosis and involving retina had worst prognosis.

Keywords: ocular morbidity, eye trauma, RTA, eye injury

Procedia PDF Downloads 39
3161 Ocular Complications, Adverse Effects of the Procedure, Side-effects of Medications Used for Graft Survival, and Preventable Vision Loss in Live-related Renal Transplant Recipients: Experience at a Transplant Centre in Pakistan

Authors: Fatema Ali Lanewala, Akhtar Jamal Khan

Abstract:

The ocular complications in renal transplant recipients at the biggest transplant center in Pakistan were seen to be diverse, multiple, and sight-threatening. These complications could mainly be due to the primary disease causing renal failure, the process of transplantation, and/or the medications used pre and post-transplantation. A retrospective case series recently published in the Journal of Pakistan Medical Association highlights the common ocular pathologies encountered in renal transplant population. Majority of the patients suffered from cataract, which is a known side-effect of long-term steroids routinely used for graft survival. There was a unique finding in Pakistani population, never reported before from any other transplant centre world over; a large number of recipients was reported to be suffering from night blindness, which significantly improved on vitamin A supplementation. There were a variety of other ocular complications seen which emphasizes the necessity of ocular care and routine examination of transplant recipient’s eyes by an ophthalmologist in order to avoid visual compromise and improve the quality of life of the transplant recipient.

Keywords: cataract, night blindness, ocular complications, renal transplantation

Procedia PDF Downloads 64
3160 Ocular Immunology: In Face of Immune Privilege the Eye Remains Vulnerable to Autoimmune and Inflammatory-Mediated Diseases

Authors: Husham Bayazed

Abstract:

Purpose of Presentation: The eye is one of a few sites in the body with immune privilege (IP). However, this IP is relatively easily bypassed in the face of sufficient strong local or systemic immunological responses. As immune responses are crucial elements of the repair response, the eye has developed distinct mechanisms to deliver immune responses to injury in the avascular regions of the eye. This presentation may cover and provide an overview of the mechanisms that dictate immune cell trafficking to the local ocular microenvironment in response to different autoimmune and inflammatory-mediated diseases. Recent Findings: Literature reviews declare that immune responses and inflammation play a key role in a diverse range of eye diseases. In recent years, our understanding of ocular immune responses has widely spread in ocular surface inflammation, uveitis, age-related macular degeneration (AMD), glaucoma, transplantation rejection, and other ocular diseases. It is becoming increasingly clear that multiple seemingly unrelated diseases involve immune responses with common themes in their ocular pathogenesis. Recent studies are focusing on elucidating the pathogenesis of ocular inflammatory disease to identify new targets for immunotherapy that will not only improve efficacy but also minimize adverse effects from traditional therapy. Summary: While IP was believed to protect the eye from day-to-day inflammatory insults, however, it is relatively easily breached in the face of different strong local or systemic immunological and inflammatory responses. Therefore, the ocular immune response encapsulates the full range of classical and non-classical immune responses and demonstrates many features which are reflected in other tissues, but eye tissues, by modifying these responses, may reveal unexpected and novel findings which are relevant to immune responses generally. This may have therapeutic potential for new targeting immunotherapy, restoring immune tolerance in ocular autoimmune and inflammatory diseases, and preventing rejection such as stem cells, currently being considered for treatment of worldwide blinding diseases such as AMD.

Keywords: ocular diseases, immunology, immune privilege, immunotherapy

Procedia PDF Downloads 48
3159 Study of Crashworthiness Behavior of Thin-Walled Tube under Axial Loading by Using Computational Mechanics

Authors: M. Kamal M. Shah, Noorhifiantylaily Ahmad, O. Irma Wani, J. Sahari

Abstract:

This paper presents the computationally mechanics analysis of energy absorption for cylindrical and square thin wall tubed structure by using ABAQUS/explicit. The crashworthiness behavior of AISI 1020 mild steel thin-walled tube under axial loading has been studied. The influence effects of different model’s cross-section, as well as model length on the crashworthiness behavior of thin-walled tube, are investigated. The model was placed on loading platform under axial loading with impact velocity of 5 m/s to obtain the deformation results of each model under quasi-static loading. The results showed that model undergoes different deformation mode exhibits different energy absorption performance.

Keywords: axial loading, computational mechanics, energy absorption performance, crashworthiness behavior, deformation mode

Procedia PDF Downloads 406
3158 Aerodynamic Design of Axisymmetric Supersonic Nozzle Used by an Optimization Algorithm

Authors: Mohammad Mojtahedpoor

Abstract:

In this paper, it has been studied the method of optimal design of the supersonic nozzle. It could make viscous axisymmetric nozzles that the quality of their outlet flow is quite desired. In this method, it is optimized the divergent nozzle, at first. The initial divergent nozzle contour is designed through the method of characteristics and adding a suitable boundary layer to the inviscid contour. After that, it is made a proper grid and then simulated flow by the numerical solution and AUSM+ method by using the operation boundary condition. At the end, solution outputs are investigated and optimized. The numerical method has been validated with experimental results. Also, in order to evaluate the effectiveness of the present method, the nozzles compared with the previous studies. The comparisons show that the nozzles obtained through this method are sufficiently better in some conditions, such as the flow uniformity, size of the boundary layer, and obtained an axial length of the nozzle. Designing the convergent nozzle part affects by flow uniformity through changing its axial length and input diameter. The results show that increasing the length of the convergent part improves the output flow uniformity.

Keywords: nozzle, supersonic, optimization, characteristic method, CFD

Procedia PDF Downloads 148
3157 Assessment of Ocular Morbidity, Knowledge and Barriers to Access Eye Care Services among the Children Live in Offshore Island, Bangladesh

Authors: Abir Dey, Shams Noman

Abstract:

Introduction: Offshore Island is the remote and isolated area from the terrestrial mainland. They are deprived of their needs. The children from an offshore island are usually underserved in the case of health care because it is a remote area where the health care systems are quite poor compared to mainland. So, the proper information is required for appropriate planning to reduce underlying causes behind visual deprivation among the surviving children of the Offshore Island. Purpose: The purpose of this study was to determine ocular morbidities, knowledge, and barriers of eye care services among children in an Offshore Island. Methods: The study team visited, and all data were collected from different rural communities at Sandwip Upazila, Chittagong district for screening the children aged 5-16 years old by doing spot examination. The whole study was conducted in both qualitative and quantitative methods. To determine ocular status of children, examinations were done under skilled Ophthalmologists and Optometrists. A focus group discussion was held. The sample size was 490. It was a community based descriptive study and the sampling method was purposive sampling. Results: In total 490 children, about 56.90% were female and 43.10% were male. Among them 456 were school-going children (93.1%) and 34 were non-school going children (6.9%). In this study the most common ocular morbidity was Allergic Conjunctivitis (35.2%). Other mentionable ocular morbidities were Refractive error (27.7%), Blepharitis (13.8%), Meibomian Gland Dysfunction (7.5%), Strabismus (6.3%) and Amblyopia (6.3%). Most of the non-school going children were involved in different types of domestic work like farming, fishing, etc. About 90.04% children who had different ocular abnormalities could not attend to the doctor due to various reasons. Conclusions: The ocular morbidity was high in rate on the offshore island. Eye health care facility was also not well established there. Awareness should be raised about necessity of maintaining hygiene and eye healthcare among the island people. Timely intervention through available eye care facilities and management can reduce the ocular morbidity rate in that area.

Keywords: morbidities, screening, barriers, offshore island, knowledge

Procedia PDF Downloads 118
3156 Ocular Manifestations of Recent Viral Pandemics: A Literature Review

Authors: Mohammad J. J. Taha, Mohammad T. Abuawwad, Warda A. Alrubasy, Shams Khalid Sameer, Taleb Alsafi, Yaqeen Al-Bustanji, Luai Abu-Ismail, Abdulqadir J. Nashwan

Abstract:

Viral pandemics often take the world by storm, urging the medical community to prioritize the most evident systemic manifestations, often causing ocular manifestations to go unnoticed. This literature review aims to highlight the ocular complications of monkeypox, SARS-CoV-2, MERS, ebola, H1N1, and zika viruses as the most recent viral pandemics. Since the emergence of the newly resurfacing monkeypox and the novel SARS-CoV-2, research aiming to uncover the effects of these pandemics began right away. Moreover, it also discusses the ocular complications of the vaccines and treatments that were used in the scope of the viral pandemics. To add, this work discussed the role of the eye as an important route of viral transmission, and thereafter, the American Academy of Ophthalmology (AAO) recommendations to reduce the incidence of viral transmission were mentioned. Finally, this paper aims to outline a platform for researchers who are interested in further investigating eye-related viral manifestations.

Keywords: ophthalmology, monkeypox, ebola, zika, MERS, H1N1, influenza, COVID-19

Procedia PDF Downloads 93
3155 A Comprehensive Review of Axial Flux Machines and Its Applications

Authors: Shahbaz Amin, Sabir Hussain Shah, Sahib Khan

Abstract:

This paper presents a thorough review concerning the design types of axial flux permanent magnet machines (AFPM) in terms of different features such as construction, design, materials, and manufacturing. Particular emphasis is given on the design and performance analysis of AFPM machines. A comparison among different permanent magnet machines is also provided. First of all, early and modern axial flux machines are mentioned. Secondly, rotor construction of different axial flux machines is described, then different stator constructions are mentioned depending upon the presence of slots and stator back iron. Then according to the arrangement of the rotor stator structure the machines are classified into single, double and multi-stack arrangements. Advantages, disadvantages and applications of each type of rotor and stator are pointed out. Finally on the basis of the reviewed literature merits, demerits, features and application of different axial flux machines structures are explained and clarified. Thus, this paper provides connection between the machines that are currently being used in industry and the developments of AFPM throughout the years.

Keywords: axial flux machines, axial flux applications, coreless machines, PM machines

Procedia PDF Downloads 174
3154 Bilateral Retinitis in Q Fever

Authors: Carl Eiselen, Stephen O’Hagan

Abstract:

Background: Q fever, caused by the obligate intracellular bacterium Coxiella burnetii, is an infectious disease with variable systemic manifestations. Its potential to cause ocular complications has not been reported before in Australia. This case study explores the unusual presentation of asymptomatic acute multifocal retinitis (AMR) in a patient with acute Q fever endocarditis and hepatitis in rural Queensland, Australia. Case Presentation: A 48-year-old male gardener presented with flu-like symptoms, weight loss, and encephalopathy. Despite systemic malaise, he had no ocular symptoms. Laboratory investigations confirmed acute Q fever, and imaging studies identified hepatic involvement and endocarditis. The retinal screening revealed asymptomatic AMR, corroborated by fundus examination and SD-OCT. Following treatment with Doxycycline and hydroxychloroquine, both systemic and ocular manifestations improved. Discussion: This is the first documented case of asymptomatic AMR associated with Q fever. The patient’s lack of autoantibodies challenges the established understanding of Q fever endocarditis and suggests potential alternative mechanisms. Conclusion: This case report expands our understanding of the multi-systemic impact of Q fever, highlighting the need for comprehensive clinical evaluation and including retinal screening in the setting of acute infection. The disease's underlying mechanism for ocular involvement is not yet established.

Keywords: Coxiella Burnetti, Q fever, ocular manifestation, acute multifocal retintis, endocarditis

Procedia PDF Downloads 28
3153 Use of Regression Analysis in Determining the Length of Plastic Hinge in Reinforced Concrete Columns

Authors: Mehmet Alpaslan Köroğlu, Musa Hakan Arslan, Muslu Kazım Körez

Abstract:

Basic objective of this study is to create a regression analysis method that can estimate the length of a plastic hinge which is an important design parameter, by making use of the outcomes of (lateral load-lateral displacement hysteretic curves) the experimental studies conducted for the reinforced square concrete columns. For this aim, 170 different square reinforced concrete column tests results have been collected from the existing literature. The parameters which are thought affecting the plastic hinge length such as cross-section properties, features of material used, axial loading level, confinement of the column, longitudinal reinforcement bars in the columns etc. have been obtained from these 170 different square reinforced concrete column tests. In the study, when determining the length of plastic hinge, using the experimental test results, a regression analysis have been separately tested and compared with each other. In addition, the outcome of mentioned methods on determination of plastic hinge length of the reinforced concrete columns has been compared to other methods available in the literature.

Keywords: columns, plastic hinge length, regression analysis, reinforced concrete

Procedia PDF Downloads 442
3152 Research on Axial End Flux Leakage and Detent Force of Transverse Flux PM Linear Machine

Authors: W. R. Li, J. K. Xia, R. Q. Peng, Z. Y. Guo, L. Jiang

Abstract:

According to 3D magnetic circuit of the transverse flux PM linear machine, distribution law is presented, and analytical expression of axial end flux leakage is derived using numerical method. Maxwell stress tensor is used to solve detent force of mover. A 3D finite element model of the transverse flux PM machine is built to analyze the flux distribution and detent force. Experimental results of the prototype verified the validity of axial end flux leakage and detent force theoretical derivation, the research on axial end flux leakage and detent force provides a valuable reference to other types of linear machine.

Keywords: axial end flux leakage, detent force, flux distribution, transverse flux PM linear machine

Procedia PDF Downloads 415
3151 Proniosomes as a Carrier for Ocular Drug Delivery

Authors: Rawia M. Khalil, Ghada Abd-Elbary, Mona Basha, Ghada E. A. Awad, Hadeer A. Elhashemy

Abstract:

Background: Bacterial infections of the eye are the clinical conditions responsible for ocular morbidity and blindness. Conjunctivitis is an inflammation of the conjunctiva, due to Staphylococcus aureus. Lomefloxacin HCl (LXN) is a third generation flouroquinolone antibiotic with a broad spectrum against wide range of bacteria and very effective against Staph infections especially in conjunctiva (conjunctivitis). The present study aims to develop and evaluate novel ocular proniosomal gels of Lomefloxacin Hcl (LXN); in order to improve its ocular bioavailability for the management of bacterial conjunctivitis. Materials and methods: Proniosomes were prepared by coacervation phase separation method using different types of nonionic surfactants (Span 60,40,20,Tween 20,40,60,80,Brij 35,98,72) solely and as mixtures with Span® 60. The formed gels were characterized for entrapment efficiency, vesicle size and in vitro drug release. The optimum proniosomal gel; P-LXN 7 were characterized for pH measurement, transmission electron microscopy (TEM) and differential scanning calorimetry (DSC) as well as Stability study and microbiological evaluation .The results revealed that only Span 60 was able to form stable LXN proniosomal gel when used individually while the other nonionic surfactants formed gels only in combination with Span 60 at different ratios. The optimum proniosomal gel; P-LXN 7 (Span60:Tween60, 9:1) appeared as spherical shaped vesicles having high entrapment efficiency (>80 %), appropriate vesicle size (187 nm) as well as controlled drug release over 12h. DSC confirmed the amorphous nature and the uniformity of LXN inclusion within the vesicles. Physical stability study did not show any significant changes in appearance or entrapment efficiency or vesicle size after storage for 3 months at 4°C. Ocular irritancy test revealed that P-LXN 7 was safe, well tolerable and suitable for ocular delivery. In vivo antibacterial activity of P-LXN 7 evaluated using the susceptibility test and topical therapy of induced ocular conjunctivitis confirmed the enhanced antibacterial therapeutic efficacy of the LXN-proniosomal gel compared to the commercially available LXN eye drops; Orchacin®. Conclusions: Our results suggest that proniosomal gels could provide a promising carrier of LXN for efficient ocular treatment of bacterial conjunctivitis.

Keywords: bacterial conjunctivitis, lomefloxacin HCl, ocular drug delivery, proniosomes

Procedia PDF Downloads 198
3150 Application of Relative Regional Total Energy in Rotary Drums with Axial Segregation Characteristics

Authors: Qiuhua Miao, Peng Huang, Yifei Ding

Abstract:

Particles with different properties tend to be unevenly distributed along an axial direction of the rotating drum, which is usually ignored. Therefore, it is important to study the relationship between axial segregation characteristics and particle crushing efficiency in longer drums. In this paper, a relative area total energy (RRTE) index is proposed, which aims to evaluate the overall crushing energy distribution characteristics. Based on numerical simulation verification, the proposed RRTE index can reflect the overall grinding effect more comprehensively, clearly representing crushing energy distribution in different drum areas. Furthermore, the proposed method is applied to the relation between axial segregation and crushing energy in drums. Compared with the radial section, the collision loss energy of the axial section can better reflect the overall crushing effect in long drums. The axial segregation characteristics directly affect the total energy distribution between medium and abrasive, reducing overall crushing efficiency. Therefore, the axial segregation characteristics should be avoided as much as possible in the crushing of the long rotary drum.

Keywords: relative regional total energy, crushing energy, axial segregation characteristics, rotary drum

Procedia PDF Downloads 52
3149 Eccentric Loading of CFDST Columns

Authors: Trevor N. Haas, Alexander Koen

Abstract:

Columns have traditionally been constructed of reinforced concrete or structural steel. Much attention was allocated to estimate the axial capacity of the traditional column sections to the detriment of other forms of construction. Other forms of column construction such as Concrete Filled Double Skin Tubes received little research attention, and almost no attention when subjected to eccentric loading. This paper investigates the axial capacity of columns when subjected to eccentric loading. The experimental axial capacities are compared to other established theoretical formulae on concentric loading to determine a possible relationship. The study found a good correlation between the reduction in axial capacity for different column lengths and hollow section ratios.

Keywords: CSDST, CFST, axial capacity, hollow section ratios

Procedia PDF Downloads 312
3148 Guidance on Writing Operation Notes in Ophthalmic Surgeries

Authors: Wasse Uddin Ahmed Saleh, Nawreenbinte Anwar

Abstract:

A well-written operating note is crucial as a teaching tool for providing patients with high-quality medical care and fending off medico-legal claims. In this review article, some adjustments have been advised to the operative note guidelines by the Royal College of Surgeons (RCS) for different methods of ocular anesthesia and ophthalmic procedures like cataract surgeries, kerato-refractive surgeries, glaucoma surgeries, oculoplastic surgeries, etc. Some modifications of the WHO Surgical Safety Checklist have also been mentioned, including pre-operative responsibilities of the nurses, operative assistants and operating ophthalmologists. It has become essential to assemble globally accepted structured operative note guidelines modified for each ocular surgery.

Keywords: ocular surgeries, operation notes, cataract surgery, kerato-refractive surgery, Oculoplastic surgeries, guidelines

Procedia PDF Downloads 86
3147 Investigation of Fire Damaged Reinforced Concrete Walls with Axial Force

Authors: Hyun Ah Yoon, Ji Yeon Kang, Hee Sun Kim, Yeong Soo Shin

Abstract:

Reinforced concrete (RC) shear wall system of residential buildings is popular in South Korea. RC walls are subjected to axial forces in common and the effect of axial forces on the strength loss of the fire damaged walls has not been investigated. This paper aims at investigating temperature distribution on fire damaged concrete walls having different axial loads. In the experiments, a variable of specimens is axial force ratio. RC walls are fabricated with 150mm of wall thicknesses, 750mm of lengths and 1,300mm of heights having concrete strength of 24MPa. After curing, specimens are heated on one surface with ISO-834 standard time-temperature curve for 2 hours and temperature distributions during the test are measured using thermocouples inside the walls. The experimental results show that the temperature of the RC walls exposed to fire increases as axial force ratio increases. To verify the experiments, finite element (FE) models are generated for coupled temperature-structure analyses. The analytical results of thermal behaviors are in good agreement with the experimental results. The predicted displacement of the walls decreases when the axial force increases. 

Keywords: axial force ratio, fire, reinforced concrete wall, residual strength

Procedia PDF Downloads 427
3146 Behavior Study of Concrete-Filled Thin-Walled Square Hollow Steel Stub Columns

Authors: Mostefa Mimoune

Abstract:

Test results on concrete-filled steel tubular stub columns under axial compression are presented. The study was mainly focused on square hollow section SHS columns; 27 columns were tested. The main experimental parameters considered were the thickness of the tube, columns length and cross section sizes. Existing design codes and theoretical model were used to predict load-carrying capacities of composite section to compare the accuracy of the predictions by using the recommendations of DTR-BC (Algerian code), CSA (Canadian standard), AIJ, EC4, DBJ, AISC, BS and EC4. Experimental results indicate that the studied parameters have significant influence on both the compressive load capacity and the column failure mode. All codes used in the comparison, provide higher resistance compared to those of tests. Equation method has been suggested to evaluate the axial capacity of the composite section seem to be in agreement with tests.

Keywords: axial loading, composite section, concrete-filled steel tubes, square hollow section

Procedia PDF Downloads 347
3145 Comparison of Different Intraocular Lens Power Calculation Formulas in People With Very High Myopia

Authors: Xia Chen, Yulan Wang

Abstract:

purpose: To compare the accuracy of Haigis, SRK/T, T2, Holladay 1, Hoffer Q, Barrett Universal II, Emmetropia Verifying Optical (EVO) and Kane for intraocular lens power calculation in patients with axial length (AL) ≥ 28 mm. Methods: In this retrospective single-center study, 50 eyes of 41 patients with AL ≥ 28 mm that underwent uneventful cataract surgery were enrolled. The actual postoperative refractive results were compared to the predicted refraction calculated with different formulas (Haigis, SRK/T, T2, Holladay 1, Hoffer Q, Barrett Universal II, EVO and Kane). The mean absolute prediction errors (MAE) 1 month postoperatively were compared. Results: The MAE of different formulas were as follows: Haigis (0.509), SRK/T (0.705), T2 (0.999), Holladay 1 (0.714), Hoffer Q (0.583), Barrett Universal II (0.552), EVO (0.463) and Kane (0.441). No significant difference was found among the different formulas (P = .122). The Kane and EVO formulas achieved the lowest level of mean prediction error (PE) and median absolute error (MedAE) (p < 0.05). Conclusion: The Kane and EVO formulas had a better success rate than others in predicting IOL power in high myopic eyes with AL longer than 28 mm in this study.

Keywords: cataract, power calculation formulas, intraocular lens, long axial length

Procedia PDF Downloads 31
3144 Length-Weight and Length-Length Relationships for 14 Sparidae Species, from the Northeastern Mediterranean Sea Coast of Turkey

Authors: Hacer Yeldan, Erhan Akamca, Sedat Gündogdu

Abstract:

Length-Weight and Length-length relationship were estimated of 14 species Sparidae (Boops boops, Diplodus annularis, Diplodus cervinus, Dipladus puntazzo, Diplodus sargus, Diplodus vulgaris, Lithognathus mormyrus, Oblada melanura, Pagellus acarne, Pagellus erythrinus, Pagrus auriga, Pagrus caeruleostictus, Sarpa salpa, Sparus aurata) sampled from in the Northeastern Mediterranean Sea coast of Turkey, Iskenderun Bay. Samples were collected from July 2014 to June 2015, using bottom trawl and trammel net into three different depth; 0-10 m, 10-20 m, 20-50m. Length-length relationships were determined size measurements: standard length (SL) and fork length (FL) to total length (TL) for fish species. The relationships between TL, FL and TL, SL were all linear. The values of the exponent b of the length-weight relationships ranged between 2.685 and 3.473. The type of growth for fish species was algometric growth.

Keywords: Sparidae, Iskenderun bay, length-length, length-weight relationships

Procedia PDF Downloads 255
3143 Case Report: Ocular Helminth – In Unusual Site (Lens)

Authors: Chandra Shekhar Majumder, Shamsul Haque, Khondaker Anower Hossain, Rafiqul Islam

Abstract:

Introduction: Ocular helminths are parasites that infect the eye or its adnexa. They can be either motile worms or sessile worms that form cysts. These parasites require two hosts for their life cycle, a definite host (usually a human) and an intermediate host (usually an insect). While there have been reports of ocular helminths infecting various structures of the eye, including the anterior chamber and subconjunctival space, there is no previous record of such a case involving the lens. Research Aim: The aim of this case report is to present a rare case of ocular helminth infection in the lens and to contribute to the understanding of this unusual site of infection. Methodology: This study is a case report, presenting the details and findings of an 80-year-old retired policeman who presented with severe pain, redness, and vision loss in the left eye. The examination revealed the presence of a thread-like helminth in the lens. The data for this case report were collected through clinical examination and medical records of the patient. The findings were described and presented in a descriptive manner. No statistical analysis was conducted. Case report: An 80-year-old retired policeman attended the OPD, Faridpur Medical College Hospital with the complaints of severe pain, redness and gross dimness of vision of the left eye for 5 days. He had a history of diabetes mellitus and hypertension for 3 years. On examination, L/E visual acuity was PL only, moderate ciliary congestion, KP 2+, cells 2+ and posterior synechia from 5 to 7 O’clock position was found. Lens was opaque. A thread like helminth was found under the anterior of the lens. The worm was moving and changing its position during examination. On examination of R/E, visual acuity was 6/36 unaided, 6/18 with pinhole. There was lental opacity. Slit-lamp and fundus examination were within normal limit. Patient was admitted in Faridpur Medical College Hospital. Diabetes mellitus was controlled with insulin. ICCE with PI was done on the same day of admission under depomedrol coverage. The helminth was recovered from the lens. It was thread like, about 5 to 6 mm in length, 1 mm in width and pinkish in colour. The patient followed up after 7 days, VA was HM, mild ciliary congestion, few KPs and cells were present. Media was hazy due to vitreous opacity. The worm was sent to the department of Parasitology, NIPSOM, Dhaka for identification. Theoretical Importance: This case report contributes to the existing literature on ocular helminth infections by reporting a unique case involving the lens. It highlights the need for further research to understand the mechanism of entry of helminths in the lens. Conclusion: To the best of our knowledge, this is the first reported case of ocular helminth infection in the lens. The presence of the helminth in the lens raises interesting questions regarding its pathogenesis and entry mechanism. Further study and research are needed to explore these aspects. Ophthalmologists and parasitologists should be aware of the possibility of ocular helminth infections in unusual sites like the lens.

Keywords: helminth, lens, ocular, unusual

Procedia PDF Downloads 13
3142 Influences of Plunge Speed on Axial Force and Temperature of Friction Stir Spot Welding in Thin Aluminum A1100

Authors: Suwarsono, Ario S. Baskoro, Gandjar Kiswanto, Budiono

Abstract:

Friction Stir Welding (FSW) is a relatively new technique for joining metal. In some cases on aluminum joining, FSW gives better results compared with the arc welding processes, including the quality of welds and produces less distortion.FSW welding process for a light structure and thin materials requires small forces as possible, to avoid structure deflection. The joining process on FSW occurs because of melting temperature and compressive forces, the temperature generation of caused by material deformation and friction between the cutting tool and material. In this research, High speed rotation of spindle was expected to reduce the force required for deformation. The welding material was Aluminum A1100, with thickness of 0.4 mm. The tool was made of HSS material which was shaped by micro grinding process. Tool shoulder diameter is 4 mm, and the length of pin was 0.6 mm (with pin diameter= 1.5 mm). The parameters that varied were the plunge speed (2 mm/min, 3 mm/min, 4 mm/min). The tool speed is fixed at 33,000 rpm. Responses of FSSW parameters to analyze were Axial Force (Z-Force), Temperature and the Shear Strength of welds. Research found the optimum µFSSW parameters, it can be concluded that the most important parameters in the μFSSW process was plunge speed. lowest plunge speed (2 mm / min) causing the lowest axial force (110.40 Newton). The increases of plunge speed will increase the axial force (maximum Z-Farce= 236.03 Newton), and decrease the shear strength of welds.

Keywords: friction stir spot welding, aluminum A1100, plunge speed, axial force, shear strength

Procedia PDF Downloads 285
3141 The Twelfth Rib as a Landmark for Surgery

Authors: Jake Tempo, Georgina Williams, Iain Robertson, Claire Pascoe, Darren Rama, Richard Cetti

Abstract:

Introduction: The twelfth rib is commonly used as a landmark for surgery; however, its variability in length has not been formally studied. The highly variable rib length provides a challenge for urologists seeking a consistent landmark for percutaneous nephrolithotomy and retroperitoneoscopic surgery. Methods and materials: We analysed CT scans of 100 adults who had imaging between 23rd March and twelfth April 2020 at an Australian Hospital. We measured the distance from the mid-sagittal line to the twelfth rib tip in the axial plane as a surrogate for true rib length. We also measured the distance from the twelfth rib tip to the kidney, spleen, and liver. Results: Length from the mid-sagittal line to the right twelfth rib tip varied from 46 (percentile 95%CI 40 to 57) to 136mm (percentile 95%CI 133 to 138). On the left, the distances varied from 55 (percentile 95%CI 50 to 64) to 134mm (percentile 95%CI 131 to 135). Twenty-three percent of people had an organ lying between the tip of the twelfth rib and the kidney on the right, and 11% of people had the same finding on the left. Conclusion: The twelfth rib is highly variable in its length. Similar variability was recorded in the distance from the tip to intra-abdominal organs. Due to the frequency of organs lying between the tip of the rib and the kidney, it should not be used as a landmark for accessing the kidney without prior knowledge of an individual patient’s anatomy, as seen on imaging.

Keywords: PCNL, rib, anatomy, nephrolithotomy

Procedia PDF Downloads 76
3140 Determination of the Axial-Vector from an Extended Linear Sigma Model

Authors: Tarek Sayed Taha Ali

Abstract:

The dependence of the axial-vector coupling constant gA on the quark masses has been investigated in the frame work of the extended linear sigma model. The field equations have been solved in the mean-field approximation. Our study shows a better fitting to the experimental data compared with the existing models.

Keywords: extended linear sigma model, nucleon properties, axial coupling constant, physic

Procedia PDF Downloads 415
3139 Development and in vitro Characterization of Loteprednol Etabonate-Loaded Polymeric Nanoparticles for Ocular Delivery

Authors: Abhishek Kumar Sah, Preeti K. Suresh

Abstract:

Effective drug delivery to the eye is a massive challenge, due to complicated physiological ocular barriers, rapid washout by tear and nasolachrymal drainage. Thus, most of the conventional ophthalmic formulations face the problem of low ocular bioavailability. Ophthalmic drug therapy can be improved by enhancing the precorneal drug retention along with improved drug penetration. The aim of the present investigation was to develop and evaluate a biodegradable polymer poly (D, L-lactide-co-glycolide) (PLGA) coated nanoparticulate carrier of loteprednol etabonate. PLGA nanoparticles were prepared by modified emulsification/solvent diffusion method using high-speed homogenizer followed by sonication. The nanoparticles were characterized for various parameters such as particle size, zeta potential, polydispersity index, X-ray powder diffraction (XRD), Transmission electron microscopy (TEM), in vitro drug release profile and stability. The prepared nanocarriers displayed mean particle size in the range of 271.7 to 424.4 nm, with zeta potential less than –10 mV. In vitro release in simulated tear fluid (STF) nanocarrier showed an extended release profile of loteprednol etabonate. TEM confirmed the spherical morphology and smooth surface of the particles. All the prepared formulations were found to be stable at varying temperatures.

Keywords: drug delivery, ocular delivery, polymeric nanoparticles, loteprednol etabonate

Procedia PDF Downloads 512
3138 Transverse Behavior of Frictional Flat Belt Driven by Tapered Pulley -Change of Transverse Force Under Driving State–

Authors: Satoko Fujiwara, Kiyotaka Obunai, Kazuya Okubo

Abstract:

A skew is one of important problems for designing the conveyor and transmission with frictional flat belt, in which running belt is deviated in width direction due to the transverse force applied to the belt. The skew often not only degrades the stability of the path of belt but also causes some damages of the belt and auxiliary machines. However, the transverse behavior such as the skew has not been discussed quantitatively in detail for frictional belts. The objective of this study is to clarify the transverse behavior of frictional flat belt driven by tapered pulley. Commercially available rubber flat belt reinforced by polyamide film was prepared as the test belt where the thickness and length were 1.25 mm and 630 mm, respectively. Test belt was driven between two pulleys made of aluminum alloy, where diameter and inter-axial length were 50 mm and 150 mm, respectively. Some tapered pulleys were applied where tapered angles were 0 deg (for comparison), 2 deg, 4 deg, and 6 deg. In order to alternatively investigate the transverse behavior, the transverse force applied to the belt was measured when the skew was constrained at the string under driving state. The transverse force was measured by a load cell having free rollers contacting on the side surface of the belt when the displacement in the belt width direction was constrained. The conditions of observed bending stiffness in-plane of the belt were changed by preparing three types of belts (the width of the belt was 20, 30, and 40 mm) where their observed stiffnesses were changed. The contributions of the bending stiffness in-plane of belt and initial inter-axial force to the transverse were discussed in experiments. The inter-axial force was also changed by setting a distance (about 240 mm) between the two pulleys. Influence of observed bending stiffness in-plane of the belt and initial inter-axial force on the transverse force were investigated. The experimental results showed that the transverse force was increased with an increase of observed bending stiffness in-plane of the belt and initial inter-axial force. The transverse force acting on the belt running on the tapered pulley was classified into multiple components. Those were components of forces applied with the deflection of the inter-axial force according to the change of taper angle, the resultant force by the bending moment applied on the belt winding around the tapered pulley, and the reaction force applied due to the shearing deformation. The calculation result of the transverse force was almost agreed with experimental data when those components were formulated. It was also shown that the most contribution was specified to be the shearing deformation, regardless of the test conditions. This study found that transverse behavior of frictional flat belt driven by tapered pulley was explained by the summation of those components of forces.

Keywords: skew, frictional flat belt, transverse force, tapered pulley

Procedia PDF Downloads 116
3137 The Eye Tracking Technique and the Study of Some Abstract Mathematical Concepts at the University

Authors: Tamara Díaz-Chang, Elizabeth-H Arredondo

Abstract:

This article presents the results of mixed approach research, where the ocular movements of students are examined while they solve questionnaires related to some abstract mathematical concepts. The objective of this research is to determine possible correlations between the parameters of ocular activity and the level of difficulty of the tasks. The difficulty level categories were established based on two types of criteria: a subjective one, through an evaluation, carried out by the subjects, and a behavioral one, related to obtaining the correct solution. Correlations of these criteria with ocular activity parameters, which were considered indicators of mental effort, were identified. The analysis of the data obtained allowed us to observe discrepancies in the categorization of difficulty levels based on subjective and behavioral criteria. There was a negative correlation of the eye movement parameters with the students' opinions on the level of difficulty of the questions, while a strong positive and significant correlation was noted between most of the parameters of ocular activity and the level of difficulty, determined by the percentage of correct answers. The results obtained by the analysis of the data suggest that eye movement parameters can be taken as indicators of the difficulty level of the tasks related to the study of some abstract mathematical concepts at the university.

Keywords: abstract mathematical concepts, cognitive neuroscience, eye-tracking, university education

Procedia PDF Downloads 81