Search results for: image-guided radiotherapy megavoltage computed tomography
1118 Experimental Validation of Computational Fluid Dynamics Used for Pharyngeal Flow Patterns during Obstructive Sleep Apnea
Authors: Pragathi Gurumurthy, Christina Hagen, Patricia Ulloa, Martin A. Koch, Thorsten M. Buzug
Abstract:
Obstructive sleep apnea (OSA) is a sleep disorder where the patient suffers a disturbed airflow during sleep due to partial or complete occlusion of the pharyngeal airway. Recently, numerical simulations have been used to better understand the mechanism of pharyngeal collapse. However, to gain confidence in the solutions so obtained, an experimental validation is required. Therefore, in this study an experimental validation of computational fluid dynamics (CFD) used for the study of human pharyngeal flow patterns during OSA is performed. A stationary incompressible Navier-Stokes equation solved using the finite element method was used to numerically study the flow patterns in a computed tomography-based human pharynx model. The inlet flow rate was set to 250 ml/s and such that a flat profile was maintained at the inlet. The outlet pressure was set to 0 Pa. The experimental technique used for the validation of CFD of fluid flow patterns is phase contrast-MRI (PC-MRI). Using the same computed tomography data of the human pharynx as in the simulations, a phantom for the experiment was 3 D printed. Glycerol (55.27% weight) in water was used as a test fluid at 25°C. Inflow conditions similar to the CFD study were simulated using an MRI compatible flow pump (CardioFlow-5000MR, Shelley Medical Imaging Technologies). The entire experiment was done on a 3 T MR system (Ingenia, Philips) with 108 channel body coil using an RF-spoiled, gradient echo sequence. A comparison of the axial velocity obtained in the pharynx from the numerical simulations and PC-MRI shows good agreement. The region of jet impingement and recirculation also coincide, therefore validating the numerical simulations. Hence, the experimental validation proves the reliability and correctness of the numerical simulations.Keywords: computational fluid dynamics, experimental validation, phase contrast-MRI, obstructive sleep apnea
Procedia PDF Downloads 3071117 Characterization of the MOSkin Dosimeter for Accumulated Dose Assessment in Computed Tomography
Authors: Lenon M. Pereira, Helen J. Khoury, Marcos E. A. Andrade, Dean L. Cutajar, Vinicius S. M. Barros, Anatoly B. Rozenfeld
Abstract:
With the increase of beam widths and the advent of multiple-slice and helical scanners, concerns related to the current dose measurement protocols and instrumentation in computed tomography (CT) have arisen. The current methodology of dose evaluation, which is based on the measurement of the integral of a single slice dose profile using a 100 mm long cylinder ionization chamber (Ca,100 and CPPMA, 100), has been shown to be inadequate for wide beams as it does not collect enough of the scatter-tails to make an accurate measurement. In addition, a long ionization chamber does not offer a good representation of the dose profile when tube current modulation is used. An alternative approach has been suggested by translating smaller detectors through the beam plane and assessing the accumulated dose trough the integral of the dose profile, which can be done for any arbitrary length in phantoms or in the air. For this purpose, a MOSFET dosimeter of small dosimetric volume was used. One of its recently designed versions is known as the MOSkin, which is developed by the Centre for Medical Radiation Physics at the University of Wollongong, and measures the radiation dose at a water equivalent depth of 0.07 mm, allowing the evaluation of skin dose when placed at the surface, or internal point doses when placed within a phantom. Thus, the aim of this research was to characterize the response of the MOSkin dosimeter for X-ray CT beams and to evaluate its application for the accumulated dose assessment. Initially, tests using an industrial x-ray unit were carried out at the Laboratory of Ionization Radiation Metrology (LMRI) of Federal University of Pernambuco, in order to investigate the sensitivity, energy dependence, angular dependence, and reproducibility of the dose response for the device for the standard radiation qualities RQT 8, RQT 9 and RQT 10. Finally, the MOSkin was used for the accumulated dose evaluation of scans using a Philips Brilliance 6 CT unit, with comparisons made between the CPPMA,100 value assessed with a pencil ionization chamber (PTW Freiburg TW 30009). Both dosimeters were placed in the center of a PMMA head phantom (diameter of 16 cm) and exposed in the axial mode with collimation of 9 mm, 250 mAs and 120 kV. The results have shown that the MOSkin response was linear with doses in the CT range and reproducible (98.52%). The sensitivity for a single MOSkin in mV/cGy was as follows: 9.208, 7.691 and 6.723 for the RQT 8, RQT 9 and RQT 10 beams qualities respectively. The energy dependence varied up to a factor of ±1.19 among those energies and angular dependence was not greater than 7.78% within the angle range from 0 to 90 degrees. The accumulated dose and the CPMMA, 100 value were 3,97 and 3,79 cGy respectively, which were statistically equivalent within the 95% confidence level. The MOSkin was shown to be a good alternative for CT dose profile measurements and more than adequate to provide accumulated dose assessments for CT procedures.Keywords: computed tomography dosimetry, MOSFET, MOSkin, semiconductor dosimetry
Procedia PDF Downloads 3061116 In vivo Mechanical Characterization of Facial Skin Combining Digital Image Correlation and Finite Element
Authors: Huixin Wei, Shibin Wang, Linan Li, Lei Zhou, Xinhao Tu
Abstract:
Facial skin is a biomedical material with complex mechanical properties of anisotropy, viscoelasticity, and hyperelasticity. The mechanical properties of facial skin are crucial for a number of applications including facial plastic surgery, animation, dermatology, cosmetic industry, and impact biomechanics. Skin is a complex multi-layered material which can be broadly divided into three main layers, the epidermis, the dermis, and the hypodermis. Collagen fibers account for 75% of the dry weight of dermal tissue, and it is these fibers which are responsible for the mechanical properties of skin. Many research on the anisotropic mechanical properties are mainly concentrated on in vitro, but there is a great difference between in vivo and in vitro for mechanical properties of the skin. In this study, we presented a method to measure the mechanical properties of facial skin in vivo. Digital image correlation (DIC) and indentation tests were used to obtain the experiment data, including the deformation of facial surface and indentation force-displacement curve. Then, the experiment was simulated using a finite element (FE) model. Application of Computed Tomography (CT) and reconstruction techniques obtained the real tissue geometry. A three-dimensional FE model of facial skin, including a bi-layer system, was obtained. As the epidermis is relatively thin, the epidermis and dermis were regarded as one layer and below it was hypodermis in this study. The upper layer was modeled as a Gasser-Ogden-Holzapfel (GOH) model to describe hyperelastic and anisotropic behaviors of the dermis. The under layer was modeled as a linear elastic model. In conclusion, the material properties of two-layer were determined by minimizing the error between the FE data and experimental data.Keywords: facial skin, indentation test, finite element, digital image correlation, computed tomography
Procedia PDF Downloads 1061115 Non-Destructive Testing of Metal Pipes with Ultrasonic Sensors Based on Determination of Maximum Ultrasonic Frequency
Authors: Herlina Abdul Rahim, Javad Abbaszadeh, Ruzairi Abdul Rahim
Abstract:
In this research, the non-invasive ultrasonic transmission tomography is investigated. In order to model the ultrasonic wave scattering for different thickness of metal pipes, two-dimensional (2D) finite element modeling (FEM) has been utilized. The wall thickness variation of the metal pipe and its influence on propagation of the ultrasonic pressure wave are explored in this paper, includes frequency analysing in order to find the maximum applicable frequency. The simulation results have been compared to experimental data and are shown to provide key insight for this well-defined experimental case by explaining the achieved reconstructed images from experimental setup. Finally, the experimental results which are useful for further investigation for the application of ultrasonic transmission tomography in industry are illustrated.Keywords: ultrasonic transmission tomography, ultrasonic sensors, ultrasonic wave, non-invasive tomography, metal pipe
Procedia PDF Downloads 3511114 X-Ray Detector Technology Optimization in Computed Tomography
Authors: Aziz Ikhlef
Abstract:
Most of multi-slices Computed Tomography (CT) scanners are built with detectors composed of scintillator - photodiodes arrays. The photodiodes arrays are mainly based on front-illuminated technology for detectors under 64 slices and on back-illuminated photodiode for systems of 64 slices or more. The designs based on back-illuminated photodiodes were being investigated for CT machines to overcome the challenge of the higher number of runs and connection required in front-illuminated diodes. In backlit diodes, the electronic noise has already been improved because of the reduction of the load capacitance due to the routing reduction. This is translated by a better image quality in low signal application, improving low dose imaging in large patient population. With the fast development of multi-detector-rows CT (MDCT) scanners and the increasing number of examinations, the clinical community has raised significant concerns on radiation dose received by the patient in both medical and regulatory community. In order to reduce individual exposure and in response to the recommendations of the International Commission on Radiological Protection (ICRP) which suggests that all exposures should be kept as low as reasonably achievable (ALARA), every manufacturer is trying to implement strategies and solutions to optimize dose efficiency and image quality based on x-ray emission and scanning parameters. The added demands on the CT detector performance also comes from the increased utilization of spectral CT or dual-energy CT in which projection data of two different tube potentials are collected. One of the approaches utilizes a technology called fast-kVp switching in which the tube voltage is switched between 80 kVp and 140 kVp in fraction of a millisecond. To reduce the cross-contamination of signals, the scintillator based detector temporal response has to be extremely fast to minimize the residual signal from previous samples. In addition, this paper will present an overview of detector technologies and image chain improvement which have been investigated in the last few years to improve the signal-noise ratio and the dose efficiency CT scanners in regular examinations and in energy discrimination techniques. Several parameters of the image chain in general and in the detector technology contribute in the optimization of the final image quality. We will go through the properties of the post-patient collimation to improve the scatter-to-primary ratio, the scintillator material properties such as light output, afterglow, primary speed, crosstalk to improve the spectral imaging, the photodiode design characteristics and the data acquisition system (DAS) to optimize for crosstalk, noise and temporal/spatial resolution.Keywords: computed tomography, X-ray detector, medical imaging, image quality, artifacts
Procedia PDF Downloads 1921113 A Novel Study Contrasting Traditional Autopsy with Post-Mortem Computed Tomography in Falls Leading to Death
Authors: Balaji Devanathan, Gokul G., Abilash S., Abhishek Yadav, Sudhir K. Gupta
Abstract:
Background: As an alternative to the traditional autopsy, a virtual autopsy is carried out using scanning and imaging technologies, mainly post-mortem computed tomography (PMCT). This facility aims to supplement traditional autopsy results and reduce or eliminate internal dissection in subsequent autopsies. For emotional and religious reasons, the deceased's relatives have historically disapproved such interior dissection. The non-invasive, objective, and preservative PMCT is what friends and family would rather have than a traditional autopsy. Additionally, it aids in the examination of the technologies and the benefits and drawbacks of each, demonstrating the significance of contemporary imaging in the field of forensic medicine. Results: One hundred falls resulting in fatalities was analysed by the writers. Before the autopsy, each case underwent a PMCT examination using a 16-slice Multi-Slice CT spiral scanner. By using specialised software, MPR and VR reconstructions were carried out following the capture of the raw images. The accurate detection of fractures in the skull, face bones, clavicle, scapula, and vertebra was better observed in comparison to a routine autopsy. The interpretation of pneumothorax, Pneumoperitoneum, pneumocephalus, and hemosiuns are much enhanced by PMCT than traditional autopsy. Conclusion. It is useful to visualise the skeletal damage in fall from height cases using a virtual autopsy based on PMCT. So, the ideal tool in traumatising patients is a virtual autopsy based on PMCT scans. When assessing trauma victims, PMCT should be viewed as an additional helpful tool to traditional autopsy. This is because it can identify additional bone fractures in body parts that are challenging to examine during autopsy, such as posterior regions, which helps the pathologist reconstruct the victim's life and determine the cause of death.Keywords: PMCT, fall from height, autopsy, fracture
Procedia PDF Downloads 311112 Alternating Electric fields-Induced Senescence in Glioblastoma
Authors: Eun Ho Kim
Abstract:
Innovations have conjured up a mode of treating GBM cancer cells in the newly diagnosed patients in a period of 4.9 months at an improved median OS, which brings along only a few minor side effects in the phase III of the clinical trial. This mode has been termed the Alternating Electric Fields (AEF). The study at hand is aimed at determining whether the AEF treatment is beneficial in sensitizing the GBM cancer cells through the process of increasing the AEF –induced senescence. The methodology to obtain the findings for this research ranged across various components, such as obtaining and testing SA-β-gal staining, flow cytometry, Western blotting, morphology, and Positron Emission Tomography (PET) / Computed Tomography (CT), immunohistochemical staining and microarray. The number of cells that displayed a senescence-specific morphology and positive SA-ß-Gal activity gradually increased up to 5 days. These results suggest that p16, p21 and p27 are essential regulators of AEF -induced senescence via NF-κB activation. The results showed that the AEF treatment is functional in enhancing the AEF –induced senescence in the GBM cells via an apoptosis- independent mechanism. This research concludes that this mode of treatment is a trustworthy protocol that can be effectively employed to overcome the limitations of the conventional mode of treatment on GBM.Keywords: alternating electric fields, senescence, glioblastoma, cell death
Procedia PDF Downloads 841111 Thermomechanical Deformation Response in Cold Sprayed SiCp/Al Composites: Strengthening, Microstructure Characterization, and Thermomechanical Properties
Authors: L. Gyansah, Yanfang Shen, Jiqiang Wang, Tianying Xiong
Abstract:
SiCₚ/ pure Al composites with different SiC fractions (20 wt %, 30 wt %, and 40 wt %) were precisely cold sprayed, followed by hot axial-compression tests at deformation temperatures of 473 K to 673 K, leading to failure of specimens through routine crack propagation in their multiphase. The plastic deformation behaviour with respect to the SiCₚ contents and the deformation temperatures were studied at strain rate 1s-1.As-sprayed and post-failure specimens were analyzed by X-ray computed tomography (XCT), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Quasi-static thermomechanical testing results revealed that compressive strength (UTS = 228 MPa and 30.4 %) was the highest in the composites that was thermomechanically compressed at 473 K compared to those of the as-sprayed, while the as-sprayed exhibited a compressive strength of 182.8 MPa related to the increment in SiC fraction. Strength—plasticity synergy was promoted by dynamic recrystallization (DRX) through strengthening and refinement of the grains. The DRX degree depends relevantly on retainment of the uniformly ultrafine SiCₚ particulates, the pinning effects of the interfaces promoted by the ultrafine grain structures (UFG), and the higher deformation temperature. Reconstructed X-ray computed tomography data revealed different crack propagation mechanisms. A single-plane shear crack with multi-laminates fracture morphology yields relatively through the as-sprayed and as-deformed at 473 K deposits, while a multiphase plane shear cracks preeminently existed in high temperature deformed deposits resulting in multiphase-interface delaminations. Three pertinent strengthening mechanisms, videlicet, SiCp dispersed strengthening, refined grain strengthening, and dislocation strengthening, existed in the gradient microstructure, and their detailed contributions to the thermomechanical properties were discussed.Keywords: cold spraying, hot deformation, deformation temperature, thermomechancal properties, SiC/Al composite
Procedia PDF Downloads 991110 The Superiority of 18F-Sodium Fluoride PET/CT for Detecting Bone Metastases in Comparison with Other Bone Diagnostic Imaging Modalities
Authors: Mojtaba Mirmontazemi, Habibollah Dadgar
Abstract:
Bone is the most common metastasis site in some advanced malignancies, such as prostate and breast cancer. Bone metastasis generally indicates fewer prognostic factors in these patients. Different radiological and molecular imaging modalities are used for detecting bone lesions. Molecular imaging including computed tomography, magnetic resonance imaging, planar bone scintigraphy, single-photon emission tomography, and positron emission tomography as noninvasive visualization of the biological occurrences has the potential to exact examination, characterization, risk stratification and comprehension of human being diseases. Also, it is potent to straightly visualize targets, specify clearly cellular pathways and provide precision medicine for molecular targeted therapies. These advantages contribute implement personalized treatment for each patient. Currently, NaF PET/CT has significantly replaced standard bone scintigraphy for the detection of bone metastases. On one hand, 68Ga-PSMA PET/CT has gained high attention for accurate staging of primary prostate cancer and restaging after biochemical recurrence. On the other hand, FDG PET/CT is not commonly used in osseous metastases of prostate and breast cancer as well as its usage is limited to staging patients with aggressive primary tumors or localizing the site of disease. In this article, we examine current studies about FDG, NaF, and PSMA PET/CT images in bone metastases diagnostic utility and assess response to treatment in patients with breast and prostate cancer.Keywords: skeletal metastases, fluorodeoxyglucose, sodium fluoride, molecular imaging, precision medicine, prostate cancer (68Ga-PSMA-11)
Procedia PDF Downloads 1061109 Diagnostic Properties of Exercise or Pharmacological Stress Myocardial Perfusion Scintigraphy in Per-Vessel Basis: A Clinical Validation Study
Authors: Ahmadreza Bagheri, Seyyed S. Eftekhari, Shervin Rashidinia
Abstract:
Background: Various stress tests have been proposed yet to assess patients with suspected coronary artery disease. However, their diagnostic properties in terms of sensitivity, specificity, and accuracy are variable and their applicability remained somewhat vague. The aim of this study is to validate per-vessel diagnostic properties of 3 types of stress myocardial perfusion scintigraphy in gated SPECT (Single-Photon Emission Computed Tomography) using either exercise or pharmacological stress testing with dipyridamole or dobutamine. Materials and Methods: Hospital records of 314 patients who referred to Imam Khomeini hospital of Tehran between September 2015 and January 2017 were completely reviewed in this study. All patients underwent coronary angiography within 3 months after stress myocardial perfusion scan. Eventually, the results were analyzed in per-vessel basis to find the proper modality for each involved vessel or scanned site. Results: The mean age of patients was 62.15 ± 4.94 years (30-85) and 35.03% were women. The overall sensitivity, specificity, and accuracy were calculated as 56.59%, 54.24%, and 55.09%, respectively. These values were 56.43% and 53.25%, 54.46% and 47.36%, 56.75% and 54.83% for dipyridamole and exercise, respectively. Ischemia of the anterior wall through exercise stress testing has the highest diagnostic accuracy in detecting LAD (Left Anterior Descending artery) involvement. Inferior wall hypokinesia and anterolateral wall ischemia during exercise stress testing have the highest diagnostic accuracy in detecting RCA (Right Coronary Artery) and LCX artery (Left Circumflex Artery) stenosis, respectively. Conclusion: Stress myocardial perfusion scan should be carried out on the basis of the findings of the preliminary investigations on suspicion of a specific coronary artery or involved myocardial wall.Keywords: dipyridamole, dobutamine, single-photon emission computed tomography, stress myocardial perfusion scintigraphy
Procedia PDF Downloads 1491108 Design, Shielding and Infrastructure of an X-Ray Diagnostic Imaging Area
Authors: D. Diaz, C. Guevara, P. Rey
Abstract:
This paper contains information about designing, shielding and protocols building in order to avoid ionizing radiation in X-Rays imaging areas as generated by X-Ray, mammography equipment, computed tomography equipment and digital subtraction angiography equipment, according to global standards. Furthermore, tools and elements about infrastructure to improve protection over patients, physicians and staff involved in a diagnostic imaging area are presented. In addition, technical parameters about each machine and the architecture designs and maps are described.Keywords: imaging area, X-ray, shielding, dose
Procedia PDF Downloads 4421107 Approaching In vivo Dosimetry for Kilovoltage X-Ray Radiotherapy
Authors: Rodolfo Alfonso, David Alonso, Albin Garcia, Jose Luis Alonso
Abstract:
Recently a new kilovoltage radiotherapy unit model Xstrahl 200 - donated to the INOR´s Department of Radiotherapy (DR-INOR) in the framework of a IAEA's technical cooperation project- has been commissioned. This unit is able to treat shallow and low deep laying lesions, as it provides 8 discrete beam qualities, from 40 to 200 kV. As part of the patient-specific quality assurance program established at DR-INOR for external beam radiotherapy, it has been recommended to implement in vivo dose measurements (IVD), as they allow effectively discovering eventual errors or failures in the radiotherapy process. For that purpose a radio-photoluminescence (RPL) dosimetry system, model XXX, -also donated to DR-INOR by the same IAEA project- has been studied and commissioned. Main dosimetric parameters of the RPL system, such as reproducibility, linearity, and filed size influence were assessed. In a similar way, the response of radiochromic EBT3 type film was investigated for purposes of IVD. Both systems were calibrated in terms of entrance surface dose. Results of the dosimetric commissioning of RPL and EBT3 for IVD, and their pre-clinical implementation through end-to-end test cases are presented. The RPL dosimetry seems more recommendable for hyper-fractionated schemes with larger fields and curved patient contours, as those in chest wall irradiations, where the use of more than one dosimeter could be required. The radiochromic system involves smaller corrections with field size, but it sensibility is lower; hence it is more adequate for hypo-fractionated treatments with smaller fields.Keywords: glass dosimetry, in vivo dosimetry, kilovotage radiotherapy, radiochromic dosimetry
Procedia PDF Downloads 3881106 Assessment of the Response of Seismic Refraction Tomography and Resistivity Imaging to the Same Geologic Environment: A Case Study of Zaria Basement Complex in North Central Nigeria
Authors: Collins C. Chiemeke, I. B. Osazuwa, S. O. Ibe, G. N. Egwuonwu, C. D. Ani, E. C. Chii
Abstract:
The study area is Zaria, located in the basement complex of northern Nigeria. The rock type forming the major part of the Zaria batholith is granite. This research work was carried out to compare the responses of seismic refraction tomography and resistivity tomography in the same geologic environment and under the same conditions. Hence, the choice of the site that has a visible granitic outcrop that extends across a narrow stream channel and is flanked by unconsolidated overburden, a neutral profile that was covered by plain overburden and a site with thick lateritic cover became necessary. The results of the seismic and resistivity tomography models reveals that seismic velocity and resistivity does not always simultaneously increase with depth, but their responses in any geologic environment are determined by changes in the mechanical and chemical content of the rock types rather than depth.Keywords: environment, resistivity, response, seismic, velocity
Procedia PDF Downloads 3411105 Estimation of Lungs Physiological Motion for Patient Undergoing External Lung Irradiation
Authors: Yousif Mohamed Y. Abdallah
Abstract:
This is an experimental study deals with detection, measurement and analysis of the periodic physiological organ motion during external beam radiotherapy; to improve the accuracy of the radiation field placement, and to reduce the exposure of healthy tissue during radiation treatments. The importance of this study is to detect the maximum path of the mobile structures during radiotherapy delivery, to define the planning target volume (PTV) and irradiated volume during both inspiration and expiration period and to verify the target volume. In addition to its role to highlight the importance of the application of Intense Guided Radiotherapy (IGRT) methods in the field of radiotherapy. The results showed (body contour was equally (3.17 + 0.23 mm), for left lung displacement reading (2.56 + 0.99 mm) and right lung is (2.42 + 0.77 mm) which the radiation oncologist to take suitable countermeasures in case of significant errors. In addition, the use of the image registration technique for automatic position control is predicted potential motion. The motion ranged between 2.13 mm and 12.2 mm (low and high). In conclusion, individualized assessment of tumor mobility can improve the accuracy of target areas definition in patients undergo Sterostatic RT for stage I, II and III lung cancer (NSCLC). Definition of the target volume based on a single CT scan with a margin of 10 mm is clearly inappropriate.Keywords: respiratory motion, external beam radiotherapy, image processing, lung
Procedia PDF Downloads 5301104 Τhe Importance of Previous Examination Results, in Futural Differential Diagnostic Procedures and Especially in the Era of Covid-19
Authors: Angelis P. Barlampas
Abstract:
Purpose or Learning Objective It is well known that previous examinations play a major role in futural diagnosis, thus avoiding unnecessary new exams that cost in time and money both for the patient and the health system. A case is presented in which past patient’s results, in combination with the least needed new tests, give an easy final diagnosis. Methods or Background A middle aged man visited the emergency department complaining of hard controlled, persisting fever for the last few days. Laboratory tests showed an elevated number of white blood cells with neutrophil shift and abnormal CRP. The patient was admitted to hospital a month ago for continuing lungs symptomatology after a recent covid-19 infection. Results or Findings Computed tomography scanning showed a solid mass with spiculating margins in right lower lobe. After intravenous iodine contrast administration, there was mildly peripheral enhancement and eccentric non enhancing area. A pneumonic cancer was suspected. Comparison with the patient’s latest computed tomography revealed no mass in the area of interest but only signs of recent post covid-19 lung parenchyma abnormalities. Any new mass that appears in a month’s time span can not be a cancer but a benign lesion. It was obvious that an abscess was the most suitable explanation. The patient was admitted to hospital, and antibiotic therapy was given, with very good results. After a few days, the patient was afebrile and in good condition. Conclusion In this case , a PET scan or a biopsy was avoided, thanks to the patient’s medical history and the availability of previous examinations. It is worthy encouraging the patients to keep their medical records and organizing more efficiently the health system with the current technology of archiving the medical examinations, too.Keywords: covid-19, chest ct, cancer, abscess, fever
Procedia PDF Downloads 541103 Pre-Malignant Breast Lesions, Methods of Treatment and Outcome
Authors: Ahmed Mostafa, Mohamed Mahmoud, Nesreen H. Hafez, Mohamed Fahim
Abstract:
This retrospective study includes 60 patients with pre-invasive breast cancer. Aim of the study: Evaluation of premalignant lesions of the breast (DCIS), different treatment methods and outcome. Patients and methods: 60 patients with DCIS were studied from the period between 2005 to 2012, for 38 patients the primary surgical method was wide local resection (WLE) (63.3%) and the other cases (22 patients, 36.7%) had mastectomy, fourteen cases from those who underwent local excision received radiotherapy, while no adjuvant radiotherapy was given for those who underwent mastectomy. In case of hormonal receptor positive DCIS lesions hormonal treatment (Tamoxifen) was given after local control. Results: No difference in overall survival between mastectomy & breast conserving therapy (wide local excision and adjuvant radiotherapy), however local recurrence rate is higher in case of breast conserving therapy, also no role of Axillary evacuation in case of DCIS. The use of hormonal therapy decreases the incidence of local recurrence by about 98%. Conclusion: The main management of DCIS is local treatment (wide local excision and radiotherapy) with hormonal treatment in case of hormone receptor positive lesions.Keywords: ductal carcinoma in situ, surgical treatment, radiotherapy, breast conserving therapy, hormonal treatment
Procedia PDF Downloads 3141102 Measuring of the Volume Ratio of Two Immiscible Liquids Using Electrical Impedance Tomography
Authors: Jiri Primas, Michal Malik, Darina Jasikova, Michal Kotek, Vaclav Kopecky
Abstract:
Authors of this paper discuss the measuring of volume ratio of two immiscible liquids in the homogenous mixture using the industrial Electrical Impedance Tomography (EIT) system ITS p2+. In the first part of the paper, the principle of EIT and the basic theory of conductivity of mixture of two components are stated. In the next part, the experiment with water and olive oil mixed with Rushton turbine is described, and the measured results are used to verify the theory. In the conclusion, the results are discussed in detail, and the accuracy of the measuring method and its advantages are also mentioned.Keywords: conductivity, electrical impedance tomography, homogenous mixture, mixing process
Procedia PDF Downloads 3951101 Dosimetric Analysis of Intensity Modulated Radiotherapy versus 3D Conformal Radiotherapy in Adult Primary Brain Tumors: Regional Cancer Centre, India
Authors: Ravi Kiran Pothamsetty, Radha Rani Ghosh, Baby Paul Thaliath
Abstract:
Radiation therapy has undergone many advancements and evloved from 2D to 3D. Recently, with rapid pace of drug discoveries, cutting edge technology, and clinical trials has made innovative advancements in computer technology and treatment planning and upgraded to intensity modulated radiotherapy (IMRT) which delivers in homogenous dose to tumor and normal tissues. The present study was a hospital-based experience comparing two different conformal radiotherapy techniques for brain tumors. This analytical study design has been conducted at Regional Cancer Centre, India from January 2014 to January 2015. Ten patients have been selected after inclusion and exclusion criteria. All the patients were treated on Artiste Siemens Linac Accelerator. The tolerance level for maximum dose was 6.0 Gyfor lenses and 54.0 Gy for brain stem, optic chiasm and optical nerves as per RTOG criteria. Mean and standard deviation values of PTV98%, PTV 95% and PTV 2% in IMRT were 93.16±2.9, 95.01±3.4 and 103.1±1.1 respectively; for 3DCRT were 91.4±4.7, 94.17±2.6 and 102.7±0.39 respectively. PTV max dose (%) in IMRT and 3D-CRT were 104.7±0.96 and 103.9±1.0 respectively. Maximum dose to the tumor can be delivered with IMRT with acceptable toxicity limits. Variables such as expertise, location of tumor, patient condition, and TPS influence the outcome of the treatment.Keywords: brain tumors, intensity modulated radiotherapy (IMRT), three dimensional conformal radiotherapy (3D-CRT), radiation therapy oncology group (RTOG)
Procedia PDF Downloads 2361100 Film Dosimetry – An Asset for Collaboration Between Cancer Radiotherapy Centers at Established Institutions and Those Located in Low- and Middle-Income Countries
Authors: A. Fomujong, P. Mobit, A. Ndlovu, R. Teboh
Abstract:
Purpose: Film’s unique qualities, such as tissue equivalence, high spatial resolution, near energy independence and comparatively less expensive dosimeter, ought to make it the preferred and widely used in radiotherapy centers in low and middle income countries (LMICs). This, however, is not always the case, as other factors that are often maybe taken for granted in advanced radiotherapy centers remain a challenge in LMICs. We explored the unique qualities of film dosimetry that can make it possible for one Institution to benefit from another’s protocols via collaboration. Methods: For simplicity, two Institutions were considered in this work. We used a single batch of films (EBT-XD) and established a calibration protocol, including scan protocols and calibration curves, using the radiotherapy delivery system at Institution A. We then proceeded and performed patient-specific QA for patients treated on system A (PSQA-A-A). Films from the same batch were then sent to a remote center for PSQA on radiotherapy delivery system B. Irradiations were done at Institution B and then returned to Institution A for processing and analysis (PSQA-B-A). The following points were taken into consideration throughout the process (a) A reference film was irradiated to a known dose on the same system irradiating the PSQA film. (b) For calibration, we utilized the one-scan protocol and maintained the same scan orientation of the calibration, PSQA and reference films. Results: Gamma index analysis using a dose threshold of 10% and 3%/2mm criteria showed a gamma passing rate of 99.8% and 100% for the PSQA-A-A and PSQA-B-A, respectively. Conclusion: This work demonstrates that one could use established film dosimetry protocols in one Institution, e.g., an advanced radiotherapy center and apply similar accuracies to irradiations performed at another institution, e.g., a center located in LMIC, which thus encourages collaboration between the two for worldwide patient benefits.Keywords: collaboration, film dosimetry, LMIC, radiotherapy, calibration
Procedia PDF Downloads 691099 The Invaluable Contributions of Radiography and Radiotherapy in Modern Medicine
Authors: Sahar Heidary
Abstract:
Radiography and radiotherapy have emerged as crucial pillars of modern medical practice, revolutionizing diagnostics and treatment for a myriad of health conditions. This abstract highlights the pivotal role of radiography and radiotherapy in favor of healthcare and society. Radiography, a non-invasive imaging technique, has significantly advanced medical diagnostics by enabling the visualization of internal structures and abnormalities within the human body. With the advent of digital radiography, clinicians can obtain high-resolution images promptly, leading to faster diagnoses and informed treatment decisions. Radiography plays a pivotal role in detecting fractures, tumors, infections, and various other conditions, allowing for timely interventions and improved patient outcomes. Moreover, its widespread accessibility and cost-effectiveness make it an indispensable tool in healthcare settings worldwide. On the other hand, radiotherapy, a branch of medical science that utilizes high-energy radiation, has become an integral component of cancer treatment and management. By precisely targeting and damaging cancerous cells, radiotherapy offers a potent strategy to control tumor growth and, in many cases, leads to cancer eradication. Additionally, radiotherapy is often used in combination with surgery and chemotherapy, providing a multifaceted approach to combat cancer comprehensively. The continuous advancements in radiotherapy techniques, such as intensity-modulated radiotherapy and stereotactic radiosurgery, have further improved treatment precision while minimizing damage to surrounding healthy tissues. Furthermore, radiography and radiotherapy have demonstrated their worth beyond oncology. Radiography is instrumental in guiding various medical procedures, including catheter placement, joint injections, and dental evaluations, reducing complications and enhancing procedural accuracy. On the other hand, radiotherapy finds applications in non-cancerous conditions like benign tumors, vascular malformations, and certain neurological disorders, offering therapeutic options for patients who may not benefit from traditional surgical interventions. In conclusion, radiography and radiotherapy stand as indispensable tools in modern medicine, driving transformative improvements in patient care and treatment outcomes. Their ability to diagnose, treat, and manage a wide array of medical conditions underscores their favor in medical practice. As technology continues to advance, radiography and radiotherapy will undoubtedly play an ever more significant role in shaping the future of healthcare, ultimately saving lives and enhancing the quality of life for countless individuals worldwide.Keywords: radiology, radiotherapy, medical imaging, cancer treatment
Procedia PDF Downloads 661098 Predictive Value of ¹⁸F-Fdg Accumulation in Visceral Fat Activity to Detect Colorectal Cancer Metastases
Authors: Amil Suleimanov, Aigul Saduakassova, Denis Vinnikov
Abstract:
Objective: To assess functional visceral fat (VAT) activity evaluated by ¹⁸F-fluorodeoxyglucose (¹⁸F-FDG) positron emission tomography/computed tomography (PET/CT) as a predictor of metastases in colorectal cancer (CRC). Materials and methods: We assessed 60 patients with histologically confirmed CRC who underwent 18F-FDG PET/CT after a surgical treatment and courses of chemotherapy. Age, histology, stage, and tumor grade were recorded. Functional VAT activity was measured by maximum standardized uptake value (SUVmax) using ¹⁸F-FDG PET/CT and tested as a predictor of later metastases in eight abdominal locations (RE – Epigastric Region, RLH – Left Hypochondriac Region, RRL – Right Lumbar Region, RU – Umbilical Region, RLL – Left Lumbar Region, RRI – Right Inguinal Region, RP – Hypogastric (Pubic) Region, RLI – Left Inguinal Region) and pelvic cavity (P) in the adjusted regression models. We also report the best areas under the curve (AUC) for SUVmax with the corresponding sensitivity (Se) and specificity (Sp). Results: In both adjusted for age regression models and ROC analysis, 18F-FDG accumulation in RLH (cutoff SUVmax 0.74; Se 75%; Sp 61%; AUC 0.668; p = 0.049), RU (cutoff SUVmax 0.78; Se 69%; Sp 61%; AUC 0.679; p = 0.035), RRL (cutoff SUVmax 1.05; Se 69%; Sp 77%; AUC 0.682; p = 0.032) and RRI (cutoff SUVmax 0.85; Se 63%; Sp 61%; AUC 0.672; p = 0.043) could predict later metastases in CRC patients, as opposed to age, sex, primary tumor location, tumor grade and histology. Conclusions: VAT SUVmax is significantly associated with later metastases in CRC patients and can be used as their predictor.Keywords: ¹⁸F-FDG, PET/CT, colorectal cancer, predictive value
Procedia PDF Downloads 1121097 Image Enhancement Algorithm of Photoacoustic Tomography Using Active Contour Filtering
Authors: Prasannakumar Palaniappan, Dong Ho Shin, Chul Gyu Song
Abstract:
The photoacoustic images are obtained from a custom developed linear array photoacoustic tomography system. The biological specimens are imitated by conducting phantom tests in order to retrieve a fully functional photoacoustic image. The acquired image undergoes the active region based contour filtering to remove the noise and accurately segment the object area for further processing. The universal back projection method is used as the image reconstruction algorithm. The active contour filtering is analyzed by evaluating the signal to noise ratio and comparing it with the other filtering methods.Keywords: contour filtering, linear array, photoacoustic tomography, universal back projection
Procedia PDF Downloads 3961096 Improving Diagnostic Accuracy of Ankle Syndesmosis Injuries: A Comparison of Traditional Radiographic Measurements and Computed Tomography-Based Measurements
Authors: Yasar Samet Gokceoglu, Ayse Nur Incesu, Furkan Okatar, Berk Nimetoglu, Serkan Bayram, Turgut Akgul
Abstract:
Ankle syndesmosis injuries pose a significant challenge in orthopedic practice due to their potential for prolonged recovery and chronic ankle dysfunction. Accurate diagnosis and management of these injuries are essential for achieving optimal patient outcomes. The use of radiological methods, such as X-ray, computed tomography (CT), and magnetic resonance imaging (MRI), plays a vital role in the accurate diagnosis of syndesmosis injuries in the context of ankle fractures. Treatment options for ankle syndesmosis injuries vary, with surgical interventions such as screw fixation and suture-button implantation being commonly employed. The choice of treatment is influenced by the severity of the injury and the presence of associated fractures. Additionally, the mechanism of injury, such as pure syndesmosis injury or specific fracture types, can impact the stability and management of syndesmosis injuries. Ankle fractures with syndesmosis injury present a complex clinical scenario, requiring accurate diagnosis, appropriate reduction, and tailored management strategies. The interplay between the mechanism of injury, associated fractures, and treatment modalities significantly influences the outcomes of these challenging injuries. The long-term outcomes and patient satisfaction following ankle fractures with syndesmosis injury are crucial considerations in the field of orthopedics. Patient-reported outcome measures, such as the Foot and Ankle Outcome Score (FAOS), provide essential information about functional recovery and quality of life after these injuries. When diagnosing syndesmosis injuries, standard measurements, such as the medial clear space, tibiofibular overlap, tibiofibular clear space, anterior tibiofibular ratio (ATFR), and the anterior-posterior tibiofibular ratio (APTF), are assessed through radiographs and computed tomography (CT) scans. These parameters are critical in evaluating the presence and severity of syndesmosis injuries, enabling clinicians to choose the most appropriate treatment approach. Despite advancements in diagnostic imaging, challenges remain in accurately diagnosing and treating ankle syndesmosis injuries. Traditional diagnostic parameters, while beneficial, may not capture the full extent of the injury or provide sufficient information to guide therapeutic decisions. This gap highlights the need for exploring additional diagnostic parameters that could enhance the accuracy of syndesmosis injury diagnoses and inform treatment strategies more effectively. The primary goal of this research is to evaluate the usefulness of traditional radiographic measurements in comparison to new CT-based measurements for diagnosing ankle syndesmosis injuries. Specifically, this study aims to assess the accuracy of conventional parameters, including medial clear space, tibiofibular overlap, tibiofibular clear space, ATFR, and APTF, in contrast with the recently proposed CT-based measurements such as the delta and gamma angles. Moreover, the study intends to explore the relationship between these diagnostic parameters and functional outcomes, as measured by the Foot and Ankle Outcome Score (FAOS). Establishing a correlation between specific diagnostic measurements and FAOS scores will enable us to identify the most reliable predictors of functional recovery following syndesmosis injuries. This comparative analysis will provide valuable insights into the accuracy and dependability of CT-based measurements in diagnosing ankle syndesmosis injuries and their potential impact on predicting patient outcomes. The results of this study could greatly influence clinical practices by refining diagnostic criteria and optimizing treatment planning for patients with ankle syndesmosis injuries.Keywords: ankle syndesmosis injury, diagnostic accuracy, computed tomography, radiographic measurements, Tibiofibular syndesmosis distance
Procedia PDF Downloads 681095 Detecting Rat’s Kidney Inflammation Using Real Time Photoacoustic Tomography
Authors: M. Y. Lee, D. H. Shin, S. H. Park, W.C. Ham, S.K. Ko, C. G. Song
Abstract:
Photoacoustic Tomography (PAT) is a promising medical imaging modality that combines optical imaging contrast with the spatial resolution of ultrasound imaging. It can also distinguish the changes in biological features. But, real-time PAT system should be confirmed due to photoacoustic effect for tissue. Thus, we have developed a real-time PAT system using a custom-developed data acquisition board and ultrasound linear probe. To evaluate performance of our system, phantom test was performed. As a result of those experiments, the system showed satisfactory performance and its usefulness has been confirmed. We monitored the degradation of inflammation which induced on the rat’s kidney using real-time PAT.Keywords: photoacoustic tomography, inflammation detection, rat, kidney, contrast agent, ultrasound
Procedia PDF Downloads 4531094 Trends of Cancer Patients Who Underwent Curative/radical Radiotherapy at Radiotherapy Center, Tikur Anbessa Specialized Hospital
Authors: Emeshaw Damtew Zebene, Edom Seife, Hagos Tesfay, Gurja Belay
Abstract:
Background: cancer incidence and mortality has grown rapidly throughout the world. Aging of the population, urbanization, physical inactivity, economic growth followed by smoking and drinking contributed a lot for the increased incidence of cancer all over the globe. Objective: the aim of this study was to assess a one-year trend of cancer patients who underwent curative/radical radiotherapy at radiotherapy center, Tikur Anbessa specialized hospital, Ethiopia. Methodology: We performed a prospective descriptive study of cancer patients treated with LINAC at Tikur Anbessa specialized hospital, Addis Ababa, Ethiopia, from April 2021- March 2022. A standardized questionnaire was used to collect sociodemographic and clinical characteristics of the patients. Descriptive statistics and chi-square results were generated using SPSS version 24. The level of significance was obtained at 0.05. Results: Sixty-four (64) curative/radical patients-44 females and 20 males were analyzed. Majority, 27(42.2%), of the patients age range from 45 to 64, and 45(70%) of them were urban residents where a group of higher gynecologic cancer was observed.78% of the patients were with locally advanced cancer, and 54(84.4%) of them had no awareness about cancer. Generally, head & neck cancer were found the most prevalent cancer 20(31.3%), and the leading cause of cancer among women was cervical cancer 17(38.6%), where about half 7(15.9%) of them were HIV positive. Conclusion: Our finding revealed that most of curative/radical patients presented at a locally advanced stage of the disease. Hence, maintaining the already available teletherapy machines and installing additional radiotherapy centers may help in treating the patients at the early stage of the disease. Since almost all of our study participants did not have information about cancer, awareness raising mechanisms should be done. Additionally, understanding differences in cancer incidence between urban and rural is important. Key words: Cancer, Curative/radical, Radiotherapy, Tikur Anbessa Specialized HospitalKeywords: cancer, curative/radical, radiotherapy, tkur anbessa specialized hospital
Procedia PDF Downloads 751093 Predictive Value of ¹⁸F-Fluorodeoxyglucose Accumulation in Visceral Fat Activity to Detect Epithelial Ovarian Cancer Metastases
Authors: A. F. Suleimanov, A. B. Saduakassova, V. S. Pokrovsky, D. V. Vinnikov
Abstract:
Relevance: Epithelial ovarian cancer (EOC) is the most lethal gynecological malignancy, with relapse occurring in about 70% of advanced cases with poor prognoses. The aim of the study was to evaluate functional visceral fat activity (VAT) evaluated by ¹⁸F-fluorodeoxyglucose (¹⁸F-FDG) positron emission tomography/computed tomography (PET/CT) as a predictor of metastases in epithelial ovarian cancer (EOC). Materials and methods: We assessed 53 patients with histologically confirmed EOC who underwent ¹⁸F-FDG PET/CT after a surgical treatment and courses of chemotherapy. Age, histology, stage, and tumor grade were recorded. Functional VAT activity was measured by maximum standardized uptake value (SUVₘₐₓ) using ¹⁸F-FDG PET/CT and tested as a predictor of later metastases in eight abdominal locations (RE – Epigastric Region, RLH – Left Hypochondriac Region, RRL – Right Lumbar Region, RU – Umbilical Region, RLL – Left Lumbar Region, RRI – Right Inguinal Region, RP – Hypogastric (Pubic) Region, RLI – Left Inguinal Region) and pelvic cavity (P) in the adjusted regression models. We also identified the best areas under the curve (AUC) for SUVₘₐₓ with the corresponding sensitivity (Se) and specificity (Sp). Results: In both adjusted-for regression models and ROC analysis, ¹⁸F-FDG accumulation in RE (cut-off SUVₘₐₓ 1.18; Se 64%; Sp 64%; AUC 0.669; p = 0.035) could predict later metastases in EOC patients, as opposed to age, sex, primary tumor location, tumor grade, and histology. Conclusions: VAT SUVₘₐₓ is significantly associated with later metastases in EOC patients and can be used as their predictor.Keywords: ¹⁸F-FDG, PET/CT, EOC, predictive value
Procedia PDF Downloads 621092 Local Availability Influences Choice of Radical Treatment for Prostate Cancer
Authors: Jemini Vyas, Oluwatobi Adeyoe, Jenny Branagan, Chandran Tanabalan, Aakash Pai
Abstract:
Introduction: Radical prostatectomy and radiotherapy are both viable options for the treatment of localised prostate cancer. Over the years medicine has evolved towards a patient-centred approach. Patient decision-making is not motivated by clinical outcomes alone. Geographical location and ease of access to treating clinician are contributory factors. With the development of robotic surgery, prostatectomy has been centralised into tertiary centres. This has impacted on the distances that patients and their families are expected to travel. Methods: A single centre retrospective study was undertaken over a five-year period. All patients with localised prostate cancer, undergoing radical radiotherapy or prostatectomy were collected pre-centralisation. This was compared to the total number undergoing these treatments post centralisation. Results: Pre-centralisation, both radiotherapy and prostatectomy groups had to travel a median of less than five miles for treatment. Post-centralisation of pelvic surgery, prostatectomy patients had to travel a median of more than 40 miles, whilst travel distance for the radiotherapy group was unchanged. In the post centralisation cohort, there was a 63% decline in the number of patients undergoing radical prostatectomy per month from a mean of 5.1 to 1.9. The radical radiotherapy group had a concurrent 41% increase in patient numbers with a mean increase from 13.3 to 18.8 patients per month. Conclusion: Choice of radical treatment in localised prostate cancer is based on multiple factors. This study infers that local availability can influence choice of radical treatment. It is imperative that efforts are made to maintain accessibility to all viable options for prostate cancer patients, so that patient choice is not compromised.Keywords: prostate, prostatectomy, radiotherapy, centralisation
Procedia PDF Downloads 891091 An Assessment of Sexual Informational Needs of Breast Cancer Patients in Radiation Oncology
Authors: Li Hoon Lim, Nur Farhanah Said, Katie Simmons, Eric Pei Ping Pang, Sharon Mei Mei Wong
Abstract:
Background and Purpose: Research regarding the sexual impact of breast cancer treatment on Asian women is both sensitive and scarce. This study aims to assess and evaluate the sexual health needs and concerns of breast cancer radiotherapy patients. It is hoped that awareness will be increased and an appropriate intervention can be developed to address the needs of future breast cancer patients. Methods: 110 consecutive unselected breast cancer patients were recruited prospectively. Questionnaires were administered once for patient undergoing radiotherapy to the breast. This study employed an anonymous questionnaire; any breast radiotherapy patient who can read English can voluntarily receive and complete the survey. The questionnaire consisted of items addressing demographics, potential informational needs, and educational preferences. Results: Patients’ interest to address sexual concerns decreases with age (p=0.024). Coherently, sexual concerns of patients are reported to decrease with age (p=0.015) where 70% of all respondents below age 50 [age 20-29 (60%); 30-39 (56.3%); 40-49(55.1%)] have started to have sexual concerns regarding their treatment effects on their sexual health. Patients who underwent breast conservation surgery (42.2%) and reconstruction surgery (83.3%) were more likely to have concerns about sexual health versus patients who underwent mastectomy (36.7%) (p=0.032). 74.2% of patients with sexual concern regardless of age would initiate conversation with their healthcare providers (p < 0.001). Conclusions: The results showed a staggering interest of female patients wanting information on this area which would not only boost their confidence and body image but also address concerns of the effect of breast radiotherapy on sexual health during their treatment.Keywords: breast cancer, breast radiotherapy, sexual health, sexual impact
Procedia PDF Downloads 2021090 Organ Dose Calculator for Fetus Undergoing Computed Tomography
Authors: Choonsik Lee, Les Folio
Abstract:
Pregnant patients may undergo CT in emergencies unrelated with pregnancy, and potential risk to the developing fetus is of concern. It is critical to accurately estimate fetal organ doses in CT scans. We developed a fetal organ dose calculation tool using pregnancy-specific computational phantoms combined with Monte Carlo radiation transport techniques. We adopted a series of pregnancy computational phantoms developed at the University of Florida at the gestational ages of 8, 10, 15, 20, 25, 30, 35, and 38 weeks (Maynard et al. 2011). More than 30 organs and tissues and 20 skeletal sites are defined in each fetus model. We calculated fetal organ dose-normalized by CTDIvol to derive organ dose conversion coefficients (mGy/mGy) for the eight fetuses for consequential slice locations ranging from the top to the bottom of the pregnancy phantoms with 1 cm slice thickness. Organ dose from helical scans was approximated by the summation of doses from multiple axial slices included in the given scan range of interest. We then compared dose conversion coefficients for major fetal organs in the abdominal-pelvis CT scan of pregnancy phantoms with the uterine dose of a non-pregnant adult female computational phantom. A comprehensive library of organ conversion coefficients was established for the eight developing fetuses undergoing CT. They were implemented into an in-house graphical user interface-based computer program for convenient estimation of fetal organ doses by inputting CT technical parameters as well as the age of the fetus. We found that the esophagus received the least dose, whereas the kidneys received the greatest dose in all fetuses in AP scans of the pregnancy phantoms. We also found that when the uterine dose of a non-pregnant adult female phantom is used as a surrogate for fetal organ doses, root-mean-square-error ranged from 0.08 mGy (8 weeks) to 0.38 mGy (38 weeks). The uterine dose was up to 1.7-fold greater than the esophagus dose of the 38-week fetus model. The calculation tool should be useful in cases requiring fetal organ dose in emergency CT scans as well as patient dose monitoring.Keywords: computed tomography, fetal dose, pregnant women, radiation dose
Procedia PDF Downloads 1351089 Overview and Pathophysiology of Radiation-Induced Breast Changes as a Consequence of Radiotherapy Toxicity
Authors: Monika Rezacova
Abstract:
Radiation-induced breast changes are a consequence of radiotherapy toxicity over the breast tissues either related to targeted breast cancer treatment or other thoracic malignancies (eg. lung cancer). This study has created an overview of different changes and their pathophysiology. The main conditions included were skin thickening, interstitial oedema, fat necrosis, dystrophic calcifications, skin retractions, glandular atrophy, breast fibrosis and radiation induced breast cancer. This study has performed focused literature search through multiple databases including pubmed, medline and embase. The study has reviewed English as well as non English publications. As a result of the literature the study provides comprehensive overview of radiation-induced breast changes and their pathophysiology with small focus on new development and prevention.Keywords: radiotherapy toxicity, breast tissue changes, breast cancer treatment, radiation-induced breast changes
Procedia PDF Downloads 152