Search results for: bone conducted vibration
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 11864

Search results for: bone conducted vibration

11684 Vibration Absorption Strategy for Multi-Frequency Excitation

Authors: Der Chyan Lin

Abstract:

Since the early introduction by Ormondroyd and Den Hartog, vibration absorber (VA) has become one of the most commonly used vibration mitigation strategies. The strategy is most effective for a primary plant subjected to a single frequency excitation. For continuous systems, notable advances in vibration absorption in the multi-frequency system were made. However, the efficacy of the VA strategy for systems under multi-frequency excitation is not well understood. For example, for an N degrees-of-freedom (DOF) primary-absorber system, there are N 'peak' frequencies of large amplitude vibration per every new excitation frequency. In general, the usable range for vibration absorption can be greatly reduced as a result. Frequency modulated harmonic excitation is a commonly seen multi-frequency excitation example: f(t) = cos(ϖ(t)t) where ϖ(t)=ω(1+α sin⁡(δt)). It is known that f(t) has a series expansion given by the Bessel function of the first kind, which implies an infinity of forcing frequencies in the frequency modulated harmonic excitation. For an SDOF system of natural frequency ωₙ subjected to f(t), it can be shown that amplitude peaks emerge at ω₍ₚ,ₖ₎=(ωₙ ± 2kδ)/(α ∓ 1),k∈Z; i.e., there is an infinity of resonant frequencies ω₍ₚ,ₖ₎, k∈Z, making the use of VA strategy ineffective. In this work, we propose an absorber frequency placement strategy for SDOF vibration systems subjected to frequency-modulated excitation. An SDOF linear mass-spring system coupled to lateral absorber systems is used to demonstrate the ideas. Although the mechanical components are linear, the governing equations for the coupled system are nonlinear. We show using N identical absorbers, for N ≫ 1, that (a) there is a cluster of N+1 natural frequencies around every natural absorber frequency, and (b) the absorber frequencies can be moved away from the plant's resonance frequency (ω₀) as N increases. Moreover, we also show the bandwidth of the VA performance increases with N. The derivations of the clustering and bandwidth widening effect will be given, and the superiority of the proposed strategy will be demonstrated via numerical experiments.

Keywords: Bessel function, bandwidth, frequency modulated excitation, vibration absorber

Procedia PDF Downloads 125
11683 Physiopathology of Osteitis in the Diabetic Foot

Authors: Mohamed Amine Adaour, Mohamed Sadek Bachene, Mosaab Fortassi, Wafaa Siouda

Abstract:

Foot infections are responsible for a significant number of hospitalizations and amputations in diabetic patients. The objective of our study is to analyze and evaluate the management of diabetic foot in a surgical setting. A retrospective study was conducted based on a selected case of suspected diabetic foot infections of osteitis treated at the Mohamed Boudiaf hospital in Medea. The case was reiterated as a therapeutic charge, consisting of treating first the infection of the soft tissues, then the osteitis: biopsy after at least 15 days of cessation of antibiotic therapy. Successful treatment of osteitis was defined at the end of a follow-up period of complete wound healing, lack of bone resection/amputation surgery at the initial bone site during follow-up , Instead, biopsies are prescribed in the treatment of soft tissue infection. The mean duration of treatment for soft tissue infection was 2-3 weeks, the duration of the antibiotic-free window of therapy prior to bone biopsy was 2-4 weeks. This patient received medical management without surgical resection. The success rate for treating osteitis at one year was 73%, and healing at one year was 88%.It is often limited to a sausage of the foot at the cost of repeated amputations. The best management remains prevention, which necessarily involves setting up a specialized and adapted centre.

Keywords: osteitis, antibiotic therapy, bone biopsy, diabetic foot

Procedia PDF Downloads 58
11682 Effect of Ultrasonic Vibration on the Dilution, Mechanical, and Metallurgical Properties in Cladding of 308 on Mild Steel

Authors: Sandeep Singh Sandhu, Karanvir Singh Ghuman, Parminder Singh Saini

Abstract:

The aim of the present investigation was to study the effect of ultrasonic vibration on the cladding of the AISI 308 on the mild steel plates using the shielded metal arc welding (SMAW). Ultrasonic vibrations were applied to molten austenitic stainless steel during the welding process. Due to acoustically induced cavitations and streaming there is a complete mixture of the clad metal and the base metal. It was revealed that cladding of AISI 308 over mild steel along with ultrasonic vibrations result in uniform and finer grain structures. The effect of the vibration on the dilution, mechanical properties and metallographic studies were also studied. It was found that the welding done using the ultrasonic vibration has the less dilution and CVN value for the vibrated sample was also high.

Keywords: surfacing, ultrasonic vibrations, mechanical properties, shielded metal arc welding

Procedia PDF Downloads 456
11681 Orthopedic Trauma in Newborn Babies

Authors: Joanna Maj, Awais Hussain, Lyndsey Vu, Catherine Roxas

Abstract:

Background: Bone injuries in babies are common conditions that arise during delivery. Fractures of the clavicle, humerus, femur, and skull are the most common neonatal bone injuries sustained from labor and delivery. During operative deliveries, zealous tractions, ineffective delivery techniques, improper uterine incision, and inadequate relaxation of the uterus can lead to bone fractures in the newborn. Neonatal anatomy is unique. Just as children are not mini-adults, newborns are not mini children. A newborn’s anatomy and physiology are significantly different from a pediatric patient's. In this paper, we describe common orthopedic trauma in newborn babies. We provide a comprehensive overview of the different types of bone injuries in newborns. We hypothesize that the rate of bone fractures sustained at birth is higher in cases of operative deliveries. Methods: Relevant literature was selected by using the PubMed database. Search terms included orthopedic conditions in newborns, neonatal anatomy, and bone fractures in neonates during operative deliveries. Inclusion criteria included age, gender, race, type of bone injury and progression of bone injury. Exclusion criteria were limited in the medical history of cases reviewed and comorbidities. Results: This review finds that a clavicle fracture is the most common type of neonatal orthopedic injury sustained at birth in both operative and non-operative deliveries. We confirm the hypothesis that infants born via operative deliveries have a significantly higher rate of bone fractures than non-cesarean section deliveries. Conclusion: Newborn babies born via operative deliveries have a higher rate of bone fractures of the clavicle, humerus, and femur. A clavicle bone fracture in newborns is most common during emergency operative deliveries in new mothers. We conclude that infants born via an operative delivery sustained more bone injuries than infants born via non-cesarean section deliveries.

Keywords: clavicle fracture, humerus fracture, neonates, newborn orthopedics, orthopedic surgery, pediatrics, orthopedic trauma, orthopedic trauma during delivery, cesarean section, obstetrics, neonatal anatomy, neonatal fractures, operative deliveries, labor and delivery, bone injuries in neonates

Procedia PDF Downloads 74
11680 Distributed Optical Fiber Vibration Sensing Using Phase Generated Carrier Demodulation Algorithm

Authors: Zhihua Yu, Qi Zhang, Mingyu Zhang, Haolong Dai

Abstract:

Distributed fiber-optic vibration sensors are gaining extensive attention, for the advantages of high sensitivity, accurate location, light weight, large-scale monitoring, good concealment, and etc. In this paper, a novel optical fiber distributed vibration sensing system is proposed, which is based on self-interference of Rayleigh backscattering with phase generated carrier (PGC) demodulation algorithm. Pulsed lights are sent into the sensing fiber and the Rayleigh backscattering light from a certain position along the sensing fiber would interfere through an unbalanced Michelson Interferometry (MI) to generate the interference light. An improved PGC demodulation algorithm is carried out to recover the phase information of the interference signal, which carries the sensing information. Three vibration events were applied simultaneously to different positions over 2000m sensing fiber and demodulated correctly. Experiments show that the spatial resolution of is 10 m, and the noise level of the Φ-OTDR system is about 10-3 rad/√Hz, and the signal to noise ratio (SNR) is about 30.34dB. This vibration measurement scheme can be applied at surface, seabed or downhole for vibration measurements or distributed acoustic sensing (DAS).

Keywords: fiber optics sensors, Michelson interferometry, MI, phase-sensitive optical time domain reflectometry, Φ-OTDR, phase generated carrier, PGC

Procedia PDF Downloads 161
11679 Diagnostic Physiopathology of Osteitis in the Diabetic Foot

Authors: Adaour Mohamed Amine, Bachene Mohamed Sadek, Fortassi Mosaab, Siouda Wafaa

Abstract:

Foot infections are responsible for a significant number of hospitalizations and amputations in diabetic patients. The objective of our study is to analyze and evaluate the management of diabetic foot in a surgical setting. A retrospective study was conducted based on a selected case of suspected diabetic foot infections of osteitis treated at the Mohamed Boudiaf hospital in Medea. The case was reiterated as a therapeutic charge, consisting of treating first the infection of the soft tissues, then the osteitis: biopsy after at least 15 days of cessation of antibiotic therapy. Successful treatment of osteitis was defined at the end of a follow-up period of complete wound healing, lack of bone resection/amputation surgery at the initial bone site during follow-up , Instead, biopsies are prescribed in the treatment of soft tissue infection. The mean duration of treatment for soft tissue infection was 2-3 weeks, the duration of the antibiotic-free window of therapy prior to bone biopsy was 2-4 weeks. This patient received medical management without surgical resection. The success rate for treating osteitis at one year was 73% and healing at one year was 88%.It is often limited to a sausage of the foot at the cost of repeated amputations. The best management remains prevention, which necessarily involves setting up a specialized and adapted centre.

Keywords: osteitis, antibiotic therapy, bone biopsy, diabetic foot

Procedia PDF Downloads 74
11678 Egg Yolk Peptide Stimulated Osteogenic Gene Expression

Authors: Hye Kyung Kim, Myung-Gyou Kim, Kang-Hyun Leem

Abstract:

Postmenopausal osteoporosis is characterized by low bone density which leads to increased bone fragility and greater susceptibility to fracture. Current treatments for osteoporosis are dominated by drugs that inhibit bone resorption although they also suppress bone formation that may contribute to pathogenesis of osteonecrosis. To restore the extensive bone loss, there is a great need for anabolic treatments that induce osteoblasts to build new bone. Pre-osteoblastic cells produce proteins of the extra-cellular matrix, including type I collagen at first, and then to successively produce alkaline phosphatase (ALP) and osteocalcin during differentiation to osteoblasts. Finally, osteoblasts deposit calcium. Present study investigated the effects of egg yolk peptide (EYP) on osteogenic activities and bone matrix gene expressions in human osteoblastic MG-63 cells. The effects of EYP on cell proliferation, alkaline phosphatase (ALP) activity, collagen synthesis, and mineralization were measured. The expression of osteogenic genes including COL1A1 (collagen, type I, alpha 1), ALP, BGLAP (osteocalcin), and SPP1 (secreted phosphoprotein 1, osteopontin) were measured by quantitative realtime PCR. EYP dose-dependently increased MG-63 cell proliferation, ALP activity, collagen synthesis, and calcium deposition. Furthermore, COL1A1, ALP, and SPP1 gene expressions were increased by EYP treatment. Present study suggested that EYP treatment enhanced osteogenic activities and increased bone matrix osteogenicgenes. These results could provide a mechanistic explanation for the bone-strengthening effects of EYP.

Keywords: egg yolk peptide, osteoblastic MG-63 cells, alkaline phosphatase, collagen synthesis, osteogenic genes, COL1A1, osteocalcin, osteopontin

Procedia PDF Downloads 364
11677 Bone Marrow ARA, EPA, and DHA Fatty Acids are Correlated with Femur Minerals Content and Enzyme of Bone Formation in Growing Rabbits

Authors: Al-Nouri Doha Mostfa, Al-Khalifa Abdulrahman Salih

Abstract:

The effects of long-term supplementation with different dietary omega-6/omega-3 (ω-6/ω-3) polyunsaturated fatty acid (PUFAs) ratios on the bone marrow fatty acids level, plasma biomarkers of bone metabolism, and minerals content in bone were evaluated in rabbits. Weanling male and female New Zealand white rabbits were randomly assigned to five groups and fed ad libitum for 100 days on diets containing 70 g/kg different dietary oils which providing the following ω-6/ω-3 ratios: soy bean oil (SBO control, 8.68), sesame oil (SO, 21.75), fish oil (FO, 0.39), DHA algae oil (DHA, 0.63), and DHA and ARA algae oils (DHA/ARA, 0.68). The bone marrow arachidonic (ARA), eicosapentaenoic (EPA), and docosahexaenoic (DHA) fatty acid levels were significantly influenced by and reflected the dietary ω-6/ω-3 ratios fed to rabbits. Rabbits fed on the FO diet maintained a lower ω-6/ω-3 ratio and a higher EPA and DHA levels, those fed on the DHA/ARA diet maintained a lower ω-6/ω-3 ratio and a higher ARA level, while those fed on the SO diet maintained a higher ω-6/ω-3 ratio and a lower ARA level. Plasma alkaline phosphatase (ALP) activity was significantly higher in male and female rabbits fed the DHA/ARA diet compared with those fed the control, SO, FO, or DHA diets. There was a significant main effect of dietary treatment on femur calcium (Ca), phosphorous (P), magnesium (Mg), and zinc (Zn) contents in both genders. This study confirmed that different dietary oil sources with varying ω-6/ω-3 ratios significantly altered the fatty acids level of bone marrow. In addition, the significant elevation in minerals content and the maintenance of optimal Ca/P ratio in bone of DHA/ARA and DHA fed groups beside the significant elevation in ALP activity in the DHA/ARA fed group proved that marine algae oils may be promising dietary sources for promoting bone mineralization and formation, thus improving bone mass during the growth stage.

Keywords: arachidonic (ARA), docosahexaenoic (DHA), eicosapentaenoic (EPA), growing rabbits

Procedia PDF Downloads 460
11676 The Role of Bone Marrow Fatty Acids in the Early Stage of Post-Menopausal Osteoporosis

Authors: Sizhu Wang, Cuisong Tang, Lin Zhang, Guangyu Tang

Abstract:

Objective: We aimed to detect the composition of bone marrow fatty acids early after ovariectomized (OVX) surgery and explore the potential mechanism. Methods: Thirty-two female Sprague-Dawley (SD) rats (12 weeks) were randomly divided into OVX group and Sham group (N=16/group), and received ovariectomy or sham surgery respectively. After 3 and 28 days, eight rats in each group were sacrificed to detect the composition of bone marrow fatty acids by gas chromatography–mass spectrometry (GC–MS) and evaluate the trabecular bone microarchitecture by micro-CT. Significant different fatty acids in the early stage of post-menopausal osteoporosis were selected by OPLS-DA and t test. Then selected fatty acids were further studied in the process of osteogenic differentiation through RT-PCR and Alizarin Red S staining. Results: An apparent sample clustering and group separation were observed between OVX group and sham group three days after surgery, which suggested the role of bone marrow fatty acids in the early stage of postmenopausal osteoporosis. Specifically, myristate, palmitoleate and arachidonate were found to play an important role in classification between OVX group and sham group. We further investigated the effect of palmitoleate and arachidonate on osteogenic differentiation and found that palmitoleate promoted the osteogenic differentiation of MC3T3-E1 cells while arachidonate inhibited this process. Conclusion: Profound bone marrow fatty acids changes have taken place in the early stage of post-menopausal osteoporosis. Bone marrow fatty acids may begin to affect osteogenic differentiation shortly after deficiency of estrogen.

Keywords: bone marrow fatty acids, GC-MS, osteoblast, osteoporosis, post-menopausal

Procedia PDF Downloads 71
11675 Human Mesenchymal Stem Cells as a Potential Source for Cell Therapy in Liver Disorders

Authors: Laila Montaser, Hala Gabr, Maha El-Bassuony, Gehan Tawfeek

Abstract:

Orthotropic liver transplantation (OLT) is the final procedure of both end stage and metabolic liver diseases. Hepatocyte transplantation is an alternative for OLT, but the sources of hepatocytes are limited. Bone marrow mesenchymal stem cells (BM-MSCs) can differentiate into hepatocyte-like cells and are a potential alternative source for hepatocytes. The MSCs from bone marrow are a promising target population as they are capable of differentiating along multiple lineages and, at least in vitro, have significant expansion capability. MSCs from bone marrow may have the potential to differentiate in vitro and in vivo into hepatocytes. Our study examined whether mesenchymal stem cells (MSCs), which are stem cells originated from human bone marrow, are able to differentiate into functional hepatocyte-like cells in vitro. Our aim was to investigate the differentiation potential of BM-MSCs into hepatocyte-like cells. Adult stem cell therapy could solve the problem of degenerative disorders, including liver disease.

Keywords: bone marrow, differentiation, hepatocyte, stem cells

Procedia PDF Downloads 486
11674 The Effect of Implant Design on the Height of Inter-Implant Bone Crest: A 10-Year Retrospective Study of the Astra Tech Implant and Branemark Implant

Authors: Daeung Jung

Abstract:

Background: In case of patients with missing teeth, multiple implant restoration has been widely used and is inevitable. To increase its survival rate, it is important to understand the influence of different implant designs on inter-implant crestal bone resorption. There are several implant systems designed to minimize loss of crestal bone, and the Astra Tech and Brånemark Implant are two of them. Aim/Hypothesis: The aim of this 10-year study was to compare the height of inter-implant bone crest in two implant systems; the Astra Tech and the Brånemark implant system. Material and Methods: In this retrospective study, 40 consecutively treated patients were utilized; 23 patients with 30 sites for Astra Tech system and 17 patients with 20 sites for Brånemark system. The implant restoration was comprised of splinted crown in partially edentulous patients. Radiographs were taken immediately after 1st surgery, at impression making, at prosthetics setting, and annually after loading. Lateral distance from implant to bone crest, inter-implant distance was gauged, and crestal bone height was measured from the implant shoulder to the first bone contact. Calibrations were performed with known length of thread pitch distance for vertical measurement, and known diameter of abutment or fixture for horizontal measurement using ImageJ. Results: After 10 years, patients treated with Astra Tech implant system demonstrated less inter-implant crestal bone resorption when implants had a distance of 3mm or less between them. In cases of implants that had a greater than 3 mm distance between them, however, there appeared to be no statistically significant difference in crestal bone loss between two systems. Conclusion and clinical implications: In the situation of partially edentulous patients planning to have more than two implants, the inter-implant distance is one of the most important factors to be considered. If it is impossible to make sure of having sufficient inter-implant distance, the implants with less micro gap in the fixture-abutment junction, less traumatic 2nd surgery approach, and the adequate surface topography would be choice of appropriate options to minimize inter-implant crestal bone resorption.

Keywords: implant design, crestal bone loss, inter-implant distance, 10-year retrospective study

Procedia PDF Downloads 128
11673 Experimental Study on the Molecular Spring Isolator

Authors: Muchun Yu, Xue Gao, Qian Chen

Abstract:

As a novel passive vibration isolation technology, molecular spring isolator (MSI) is investigated in this paper. An MSI consists of water and hydrophobic zeolites as working medium. Under periodic excitation, water molecules intrude into hydrophobic pores of zeolites when the pressure rises and water molecules extrude from hydrophobic pores when pressure drops. At the same time, energy is stored, released and dissipated. An MSI of piston-cylinder structure was designed in this work. Experiments were conducted to investigate the stiffness properties of MSI. The results show that MSI exhibits high-static-low dynamic (HSLD) stiffness. Furthermore, factors such as the quantity of zeolites, temperature, and ions in water are proved to have an influence on the stiffness properties of MSI.

Keywords: hydrophobic zeolites, molecular spring, stiffness, vibration isolation

Procedia PDF Downloads 441
11672 Effect of Composite Material on Damping Capacity Improvement of Cutting Tool in Machining Operation Using Taguchi Approach

Authors: Siamak Ghorbani, Nikolay Ivanovich Polushin

Abstract:

Chatter vibrations, occurring during cutting process, cause vibration between the cutting tool and workpiece, which deteriorates surface roughness and reduces tool life. The purpose of this study is to investigate the influence of cutting parameters and tool construction on surface roughness and vibration in turning of aluminum alloy AA2024. A new design of cutting tool is proposed, which is filled up with epoxy granite in order to improve damping capacity of the tool. Experiments were performed at the lathe using carbide cutting insert coated with TiC and two different cutting tools made of AISI 5140 steel. Taguchi L9 orthogonal array was applied to design of experiment and to optimize cutting conditions. By the help of signal-to-noise ratio and analysis of variance the optimal cutting condition and the effect of the cutting parameters on surface roughness and vibration were determined. Effectiveness of Taguchi method was verified by confirmation test. It was revealed that new cutting tool with epoxy granite has reduced vibration and surface roughness due to high damping properties of epoxy granite in toolholder.

Keywords: ANOVA, damping capacity, surface roughness, Taguchi method, vibration

Procedia PDF Downloads 279
11671 Fabrication of Drug-Loaded Halloysite Nanotubes Containing Sodium Alginate/Gelatin Composite Scaffolds

Authors: Masoumeh Haghbin Nazarpak, Hamidreza Tolabi, Aryan Ekhlasi

Abstract:

Bone defects are mentioned as one of the most challenging clinical conditions, affecting millions of people each year. A fracture, osteoporosis, tumor, or infection usually causes these defects. At present, autologous and allogeneic grafts are used to correct bone defects, but these grafts have some difficulties, such as limited access, infection, disease transmission, and immune rejection. Bone tissue engineering is considered a new strategy for repairing bone defects. However, problems with scaffolds’ design with unique structures limit their clinical applications. In addition, numerous in-vitro studies have been performed on the behavior of bone cells in two-dimensional environments. Still, cells grow in physiological situations in the human body in a three-dimensional environment. As a result, the controlled design of porous structures with high structural complexity and providing the necessary flexibility to meet specific needs in bone tissue repair is beneficial. For this purpose, a three-dimensional composite scaffold based on gelatin and sodium alginate hydrogels is used in this research. In addition, the antibacterial drug-loaded halloysite nanotubes were introduced into the hydrogel scaffold structure to provide a suitable substrate for controlled drug release. The presence of halloysite nanotubes improved hydrogel’s properties, while the drug eliminated infection and disease transmission. Finally, it can be acknowledged that the composite scaffold prepared in this study for bone tissue engineering seems promising.

Keywords: halloysite nanotubes, bone tissue engineering, composite scaffold, controlled drug release

Procedia PDF Downloads 23
11670 3D Printing of Cold Atmospheric Plasma Treated Poly(ɛ-Caprolactone) for Bone Tissue Engineering

Authors: Dong Nyoung Heo, Il Keun Kwon

Abstract:

Three-dimensional (3D) technology is a promising method for bone tissue engineering. In order to enhance bone tissue regeneration, it is important to have ideal 3D constructs with biomimetic mechanical strength, structure interconnectivity, roughened surface, and the presence of chemical functionality. In this respect, a 3D printing system combined with cold atmospheric plasma (CAP) was developed to fabricate a 3D construct that has a rough surface with polar functional chemical groups. The CAP-etching process leads to oxidation of chemical groups existing on the polycaprolactone (PCL) surface without conformational change. The surface morphology, chemical composition, mean roughness of the CAP-treated PCL surfaces were evaluated. 3D printed constructs composed of CAP-treated PCL showed an effective increment in the hydrophilicity and roughness of the PCL surface. Also, an in vitro study revealed that CAP-treated 3D PCL constructs had higher cellular behaviors such as cell adhesion, cell proliferation, and osteogenic differentiation. Therefore, a 3D printing system with CAP can be a highly useful fabrication method for bone tissue regeneration.

Keywords: bone tissue engineering, cold atmospheric plasma, PCL, 3D printing

Procedia PDF Downloads 85
11669 Parametrization of Piezoelectric Vibration Energy Harvesters for Low Power Embedded Systems

Authors: Yannick Verbelen, Tim Dekegel, Ann Peeters, Klara Stinders, Niek Blondeel, Sam De Winne, An Braeken, Abdellah Touhafi

Abstract:

Matching an embedded electronic application with a cantilever vibration energy harvester remains a difficult endeavour due to the large number of factors influencing the output power. In the presented work, complementary balanced energy harvester parametrization is used as a methodology for simplification of harvester integration in electronic applications. This is achieved by a dual approach consisting of an adaptation of the general parametrization methodology in conjunction with a straight forward harvester benchmarking strategy. For this purpose, the design and implementation of a suitable user friendly cantilever energy harvester benchmarking platform is discussed. Its effectiveness is demonstrated by applying the methodology to a commercially available Mide V21BL vibration energy harvester, with excitation amplitude and frequency as variables.

Keywords: vibration energy harvesting, piezoelectrics, harvester parametrization, complementary balanced energy harvesting

Procedia PDF Downloads 327
11668 Free Vibration and Buckling of Rectangular Plates under Nonuniform In-Plane Edge Shear Loads

Authors: T. H. Young, Y. J. Tsai

Abstract:

A method for determining the stress distribution of a rectangular plate subjected to two pairs of arbitrarily distributed in-plane edge shear loads is proposed, and the free vibration and buckling of such a rectangular plate are investigated in this work.  The method utilizes two stress functions to synthesize the stress-resultant field of the plate with each of the stress functions satisfying the biharmonic compatibility equation. The sum of stress-resultant fields due to these two stress functions satisfies the boundary conditions at the edges of the plate, from which these two stress functions are determined. Then, the free vibration and buckling of the rectangular plate are investigated by the Galerkin method. Numerical results obtained by this work are compared with those appeared in the literature, and good agreements are observed.

Keywords: stress analysis, free vibration, plate buckling, nonuniform in-plane edge shear

Procedia PDF Downloads 127
11667 Deformation Analysis of Pneumatized Sphenoid Bone Caused Due to Elevated Intracranial Pressure Using Finite Element Analysis

Authors: Dilesh Mogre, Jitendra Toravi, Saurabh Joshi, Prutha Deshpande, Aishwarya Kura

Abstract:

In earlier days of technology, it was not possible to understand the nature of complex biomedical problems and were only left to clinical postulations. With advancement in science today, we have tools like Finite Element Modelling and simulation to solve complex biomedical problems. This paper presents how ANSYS WORKBENCH can be used to study deformation of pneumatized sphenoid bone caused by increased intracranial pressure. Intracranial pressure refers to the pressure inside the skull. The increase in the pressure above the normal range of 15mmhg can lead to serious conditions due to developed stresses and deformation. One of the areas where the deformation is suspected to occur is Sphenoid Bone. Moreover, the varying degree of pneumatization increases the complexity of the conditions. It is necessary to study deformation patterns on pneumatized sphenoid bone model at elevated intracranial pressure. Finite Element Analysis plays a major role in developing and analyzing model and give quantitative results.

Keywords: intracranial pressure, pneumatized sphenoid bone, deformation, finite element analysis

Procedia PDF Downloads 151
11666 Vibration Analysis of Functionally Graded Engesser-Timoshenko Beams Subjected to Axial Load Located on a Continuous Elastic Foundation

Authors: M. Karami Khorramabadi, A. R. Nezamabadi

Abstract:

This paper studies free vibration of functionally graded beams Subjected to Axial Load that is simply supported at both ends lies on a continuous elastic foundation. The displacement field of beam is assumed based on Engesser-Timoshenko beam theory. The Young's modulus of beam is assumed to be graded continuously across the beam thickness. Applying the Hamilton's principle, the governing equation is established. Resulting equation is solved using the Euler's Equation. The effects of the constituent volume fractions and foundation coefficient on the vibration frequency are presented. To investigate the accuracy of the present analysis, a compression study is carried out with a known data.

Keywords: functionally graded beam, free vibration, elastic foundation, Engesser-Timoshenko beam theory

Procedia PDF Downloads 377
11665 Study on Co-Relation of Prostate Specific Antigen with Metastatic Bone Disease in Prostate Cancer on Skeletal Scintigraphy

Authors: Muhammad Waleed Asfandyar, Akhtar Ahmed, Syed Adib-ul-Hasan Rizvi

Abstract:

Objective: To evaluate the ability of serum concentration of prostate specific antigen between two cutting points considering it as a predictor of skeletal metastasis on bone scintigraphy in men with prostate cancer. Settings: This study was carried out in department of Nuclear Medicine at Sindh Institute of Urology and Transplantation (SIUT) Karachi, Pakistan. Materials and Method: From August 2013 to November 2013, forty two (42) consecutive patients with prostate cancer who underwent technetium-99m methylene diphosphonate (Tc-99mMDP) whole body bone scintigraphy were prospectively analyzed. The information was collected from the scintigraphic database at a Nuclear medicine department Sindh institute of urology and transplantation Karachi Pakistan. Patients who did not have a serum PSA concentration available within 1 month before or after the time of performing the Tc-99m MDP whole body bone scintigraphy were excluded from this study. A whole body bone scintigraphy scan (from the toes to top of the head) was performed using a whole-body Moving gamma camera technique (anterior and posterior) 2–4 hours after intravenous injection of 20 mCi of Tc-99m MDP. In addition, all patients necessarily have a pathological report available. Bony metastases were determined from the bone scan studies and no further correlation with histopathology or other imaging modalities were performed. To preserve patient confidentiality, direct patient identifiers were not collected. In all the patients, Prostate specific antigen values and skeletal scintigraphy were evaluated. Results: The mean age, mean PSA, and incidence of bone metastasis on bone scintigraphy were 68.35 years, 370.51 ng/mL and 19/42 (45.23%) respectively. According to PSA levels, patients were divided into 5 groups < 10ng/mL (10/42), 10-20 ng/mL (5/42), 20-50 ng/mL (2/42), 50-100 (3/42), 100- 500ng/mL (3/42) and more than 500ng/mL (0/42) presenting negative bone scan. The incidence of positive bone scan (%) for bone metastasis for each group were O1 patient (5.26%), 0%, 03 patients (15.78%), 01 patient (5.26%), 04 patients (21.05%), and 10 patients (52.63%) respectively. From the 42 patients 19 (45.23%) presented positive scintigraphic examination for the presence of bone metastasis. 1 patient presented bone metastasis on bone scintigraphy having PSA level less than 10ng/mL, and in only 1 patient (5.26%) with bone metastasis PSA concentration was less than 20 ng/mL. therefore, when the cutting point adopted for PSA serum concentration was 10ng/mL, a negative predictive value for bone metastasis was 95% with sensitivity rates 94.74% and the positive predictive value and specificities of the method were 56.53% and 43.48% respectively. When the cutting point of PSA serum concentration was 20ng/mL the observed results for Positive predictive value and specificity were (78.27% and 65.22% respectively) whereas negative predictive value and sensitivity stood (100% and 95%) respectively. Conclusion: Results of our study allow us to conclude that serum PSA concentration of higher than 20ng/mL was the most accurate cutting point than a serum concentration of PSA higher than 10ng/mL to predict metastasis in radionuclide bone scintigraphy. In this way, unnecessary cost can be avoided, since a considerable part of prostate adenocarcinomas present low serum PSA levels less than 20 ng/mL and for these cases radionuclide bone scintigraphy could be unnecessary.

Keywords: bone scan, cut off value, prostate specific antigen value, scintigraphy

Procedia PDF Downloads 283
11664 Characterization and Degradation of 3D Printed Polycaprolactone-Freeze Dried Bone Matrix Constructs for Use in Critical Sized Bone Defects

Authors: Samantha Meyr, Eman Mirdamadi, Martha Wang, Tao Lowe, Ryan Smith, Quinn Burke

Abstract:

Critical-sized bone defects (CSD) treatment options remain a major clinical orthopedic challenge. They are uniquely contoured diseased or damaged bones and can be defined as those that will not heal spontaneously and require surgical intervention. Autografts are the current gold standard CSD treatment, which are histocompatible and provoke a minimal immunogenic response; however, they can cause donor site morbidity and will not suffice for the size required for replacement. As an alternative to traditional surgical methods, bone tissue engineering will be implemented via 3D printing methods. A freeze-dried bone matrix (FDBM) is a type of graft material available but will only function as desired when in the presence of bone growth factors. Polycaprolactone (PCL) is a known biodegradable material with good biocompatibility that has been proven manageable in 3D printing as a medical device. A 3D-extrusion printing strategy is introduced to print these materials into scaffolds for bone grafting purposes, which could be more accessible and rapid than the current standard. Mechanical, thermal, cytotoxic, and physical properties were investigated throughout a degradation period of 6 months using fibroblasts and dental pulp stem cells. PCL-FDBM scaffolds were successfully printed with high print fidelity in their respective pore sizes and allograft content. Additionally, we have created a method for evaluating PCL using differential scanning calorimetry (DSC) and have evaluated PCL degradation over roughly 6 months.

Keywords: 3D printing, bone tissue engineering, cytotoxicity, degradation, scaffolds

Procedia PDF Downloads 66
11663 Used MATLAB Code to Study the Vehicle Bridge Coupling Vibration Based On the Method of Newmark-β

Authors: Saidi Abdelkrim, Hamouine Abdelmadjid, Abdellatif Megnounif

Abstract:

The study of interaction between vehicles and bridge structures has become extremely important. Large deflections and vibration induced by heavy and high-speed vehicles affect significantly the safety and efficiency of bridge. The vibration of a bridge caused by passage of vehicles is one of the most imperative considerations in the design of a bridge as a common sort of transportation structure. A major goal of this study is to create a simplified model of a vehicle bridge system in MATLAB. The model will then be used to study the influence of parameters to vehicle-bridge vibrations.

Keywords: vehicle-bridge interaction, Newmark-β, MATLAB code

Procedia PDF Downloads 569
11662 Production, Quality Control, and Biodistribution Studies of 141ce-Edtmp as a Potential Bone Pain Palliation Agent

Authors: Fatemeh Soltani, Simindokht Shirvani Arani, Ali Bahrami Samani, Mahdi Sadeghi, Kamal Yavari

Abstract:

Cerium-141 [T1/2 = 32.501 days, Eβ (max) = 0.580 (29.8%) and 0.435(70.2%) MeV, Eγ=145.44 (48.2%) keV] possesses radionuclidic properties suitable for use in palliative therapy of bone metastases. 141Ce also has gamma energy of 145.44 keV, which resembles that of 99mTc. Therefore, the energy window is adjustable on the Tc-99m energy because of imaging studies. 141Ce can be produced through a relatively easy route that involves thermal neutron bombardment on natural CeO2 in medium flux research reactors (4–5×1013 neutrons/cm2•s). The requirement for an enriched target does not arise. Ethylenediamine tetramethylene phosphonic acid (EDTMP) was synthesized and radiolabeled with 141Ce. Complexation parameters were optimized to achieve maximum yields (>99%). The radiochemical purity of 141Ce-EDTMP was evaluated by radio-thin layer chromatography. The stability of the prepared formulation was monitored for one week at room temperature, and results showed that the preparation was stable during this period (>99%). Biodistribution studies of the complexes carried out in wild-type rats exhibited significant bone uptake with rapid clearance from blood. The properties of produced 141Ce-EDTMP suggest applying a new efficient bone pain palliative therapeutic agent to overcome metastatic bone pains.

Keywords: bone pain palliative, cerium-141, EDTMP, radiopharmaceutical

Procedia PDF Downloads 466
11661 Response of Vibration and Damping System of UV Irradiated Renewable Biopolymer

Authors: Anika Zafiah M. Rus, Nik Normunira Mat Hassan

Abstract:

Biopolymer made from renewable material are one of the most important group of polymer because of their versatility and they can be manufactured in a wide range of densities and stiffness. In this project, biopolymer based on waste vegetable oil were synthesized and crosslink with commercial polymethane polyphenyl isocyanate (known as BF).The BF was compressed by using hot compression moulding technique at 90 oC based on the evaporation of volatile matter and known as compress biopolymer (CB). The density, vibration and damping characteristic of CB were determined after UV irradiation. Treatment with titanium dioxide (TiO2) was found to affect the physical property of compress biopolymer composite (CBC). The density of CBC samples was steadily increased with an increase of UV irradiation time and TiO2 loading. The highest density of CBC samples is at 10 % of TiO2 loading of 1.1088 g/cm3 due to the amount of filler loading. The vibration and damping characteristic of CBC samples was generated at displacements of 1 mm and 1.5 mm and acceleration of 0.1 G and 0.15 G base excitation according to ASTM D3580-9. It was revealed that, the vibration and damping characteristic of CBC samples is significantly increased with the increasing of UV irradiation time, lowest thickness and percentages of TiO2 loading at the frequency range of 15 - 25 Hz. Therefore, this study indicated that the damping property of CBC could be improved upon prolonged exposure to UV irradiation.

Keywords: biopolymer flexible foam, TGA, UV irradiation, vibration and damping

Procedia PDF Downloads 433
11660 Simulated Microgravity Inhibits L-Type Calcium Channel Currents by Up-Regulation of miR-103 in Osteoblasts

Authors: Zhongyang Sun, Shu Zhang

Abstract:

In osteoblasts, L-type voltage sensitive calcium channels (LTCCs), especially the Cav1.2 LTCCs, play fundamental roles in cellular responses to external stimuli including both mechanical forces and hormonal signals. Several lines of evidence have revealed that the density of bone is increased and the resorption of bone is decreased when these calcium channels in osteoblasts are activated. And numerous studies have shown that mechanical loading promotes bone formation in the modeling skeleton, whereas removal of this stimulus in microgravity results in a reduction in bone mass. However, the effect of microgravity on LTCCs in osteoblasts is still unknown. The aim of this study was to determine whether microgravity exerts influence on LTCCs in osteoblasts and the possible mechanisms underlying. In this study, we demonstrate that simulated microgravity substantially inhibits LTCCs in osteoblast by suppressing the expression of Cav1.2. Then we show that the up-regulation of miR-103 is involved in the down-regulation of Cav1.2 expression and inhibition of LTCCs by simulated microgravity in osteoblasts. Our study provides a novel mechanism of simulated microgravity-induced adverse effects on osteoblasts, offering a new avenue to further investigate the bone loss caused by microgravity.

Keywords: L-type voltage sensitive calcium channels, Cav1.2, osteoblasts, microgravity

Procedia PDF Downloads 283
11659 A Method for Precise Vertical Position of the Implant When Using Computerized Surgical Guides and Bone Reduction

Authors: Abraham Finkelman

Abstract:

Computerized Surgical Guides have been proven to be a predictable way to perform dental implants, with a relatively high accuracy in comparison to a treatment plan. When using the CSG Bone supported, it allows us to make the necessary changes of the hard tissue prior to the implant placement and after the implant placement. The CSG gives us an accurate position for the drilling, and during the implant placement it allows us to alter the vertical position of the implant altering the final position of the abutment and avoiding any risk of any damage to the adjacent anatomical structures. Any Changes required to the bone level can be done prior to the fixation of the CSG using a reduction guide, which incur extra surgical fees and the need of a second surgical guide. Any changes of the bone level after the implant placement are at the risk of damaging the implant neck surface. The technique consists of a universal system that allows us to remove the excess bone around the implant sockets prior to the implant placement which then enables us to place the implant in the vertical position with accuracy as planned with the CSG. The systems consist of a hollow pin of different sizes and diameters. Depending on the implant system that we are using. Length sizes are from 6mm-16mm and a diameter of 2.6mm-4.8mm. Upon the completion of the drilling, the pin is then inserted into the implant socket-using the insertion tool. Once the insertion tool has unscrewed the pin, we can continue with the bone reduction. The bone reduction can be done using conventional methods upon the removal of all the excess bone around the pin. The insertion tool is then screwed into the pin and the pin is then removed. We now, have the new bone level at the crest of the implant socket which is our mark for the vertical position of the implant. In some cases, when we are locating the implant very close to anatomical structures, any form of deviation to the vertical position of the implant during the surgery, can cause damage to such anatomical structures, creating irreversible damages such as paresthesia or dysesthesia of the mandibular nerve. If we are planning for immediate loading and we have done our temporary restauration in base of our computerized plan, deviation in the vertical position of the implant will affect the position of the abutment, affecting the accuracy of the temporary prosthesis, extending the working time till we adapt the prosthesis to the new position.

Keywords: bone reduction, computer aided navigation, dental implant placement, surgical guides

Procedia PDF Downloads 308
11658 Particle Swarm Optimization Based Vibration Suppression of a Piezoelectric Actuator Using Adaptive Fuzzy Sliding Mode Controller

Authors: Jin-Siang Shaw, Patricia Moya Caceres, Sheng-Xiang Xu

Abstract:

This paper aims to integrate the particle swarm optimization (PSO) method with the adaptive fuzzy sliding mode controller (AFSMC) to achieve vibration attenuation in a piezoelectric actuator subject to base excitation. The piezoelectric actuator is a complicated system made of ferroelectric materials and its performance can be affected by nonlinear hysteresis loop and unknown system parameters and external disturbances. In this study, an adaptive fuzzy sliding mode controller is proposed for the vibration control of the system, because the fuzzy sliding mode controller is designed to tackle the unknown parameters and external disturbance of the system, and the adaptive algorithm is aimed for fine-tuning this controller for error converging purpose. Particle swarm optimization method is used in order to find the optimal controller parameters for the piezoelectric actuator. PSO starts with a population of random possible solutions, called particles. The particles move through the search space with dynamically adjusted speed and direction that change according to their historical behavior, allowing the values of the particles to quickly converge towards the best solutions for the proposed problem. In this paper, an initial set of controller parameters is applied to the piezoelectric actuator which is subject to resonant base excitation with large amplitude vibration. The resulting vibration suppression is about 50%. Then PSO is applied to search for an optimal controller in the neighborhood of this initial controller. The performance of the optimal fuzzy sliding mode controller found by PSO indeed improves up to 97.8% vibration attenuation. Finally, adaptive version of fuzzy sliding mode controller is adopted for further improving vibration suppression. Simulation result verifies the performance of the adaptive controller with 99.98% vibration reduction. Namely the vibration of the piezoelectric actuator subject to resonant base excitation can be completely annihilated using this PSO based adaptive fuzzy sliding mode controller.

Keywords: adaptive fuzzy sliding mode controller, particle swarm optimization, piezoelectric actuator, vibration suppression

Procedia PDF Downloads 120
11657 Investigation of Multiple Dynamic Vibration Absorbers' Performance in Overhead Transmission Lines

Authors: Pedro F. D. Oliveira, Rangel S. Maia, Aline S. Paula

Abstract:

As the electric energy consumption grows, the necessity of energy transmission lines increases. One of the problems caused by an oscillatory response to dynamical loads (such as wind effects) in transmission lines is the cable fatigue. Thus, the dynamical behavior of transmission cables understanding and its control is extremely important. The socioeconomic damage caused by a failure in these cables can be quite significant, from large economic losses to energy supply interruption in large regions. Dynamic Vibration Absorbers (DVA) are oscillatory elements used to mitigate the vibration of a primary system subjected to harmonic excitation. The positioning of Stockbridge (DVA for overhead transmission lines) plays an important role in mitigating oscillations of transmission lines caused by airflows. Nowadays, the positioning is defined by technical standards or commercial software. The aim of this paper is to conduct an analysis of multiple DVAs performances in cable conductors of overhead transmission lines. The cable is analyzed by a finite element method and the model is calibrated by experimental results. DVAs performance is analyzed by evaluating total cable energy, and a study of multiple DVAs positioning is conducted. The results are compared to the existing regulations showing situations where proper positioning, different from the standard, can lead to better performance of the DVA. Results also show situations where the use of multiple DVAs is appropriate.

Keywords: dynamical vibration absorber, finite element method, overhead transmission lines, structural dynamics

Procedia PDF Downloads 102
11656 Bone Mineral Density and Trabecular Bone Score in Ukrainian Men with Obesity

Authors: Vladyslav Povoroznyuk, Anna Musiienko, Nataliia Dzerovych, Roksolana Povoroznyuk

Abstract:

Osteoporosis and obesity are widespread diseases in people over 50 years associated with changes in structure and body composition. Нigher body mass index (BMI) values are associated with greater bone mineral density (BMD). However, trabecular bone score (TBS) indirectly explores bone quality, independently of BMD. The aim of our study was to evaluate the relationship between the BMD and TBS parameters in Ukrainian men suffering from obesity. We examined 396 men aged 40-89 years. Depending on their BMI all the subjects were divided into two groups: Group I – patients with obesity whose BMI was ≥ 30 kg/m2 (n=129) and Group II – patients without obesity and BMI of < 30 kg/m2 (n=267). The BMD of total body, lumbar spine L1-L4, femoral neck and forearm were measured by DXA (Prodigy, GEHC Lunar, Madison, WI, USA). The TBS of L1- L4 was assessed by means of TBS iNsight® software installed on DXA machine (product of Med-Imaps, Pessac, France). In general, obese men had a significantly higher BMD of lumbar spine L1-L4, femoral neck, total body and ultradistal forearm (p < 0.001) in comparison with men without obesity. The TBS of L1-L4 was significantly lower in obese men compared to non-obese ones (p < 0.001). BMD of lumbar spine L1-L4, femoral neck and total body significantly differ in men aged 40-49, 50-59, 60-69, and 80-89 years (p < 0.05). At the same time, in men aged 70-79 years, BMD of lumbar spine L1-L4 (p=0.46), femoral neck (p=0.18), total body (p=0.21), ultra-distal forearm (p=0.13), and TBS (p=0.07) did not significantly differ. A significant positive correlation between the fat mass and the BMD at different sites was observed. However, the correlation between the fat mass and TBS of L1-L4 was also significant, though negative.

Keywords: bone mineral density, trabecular bone score, obesity, men

Procedia PDF Downloads 440
11655 Optimal Trailing Edge Flap Positions of Helicopter Rotor for Various Thrust Coefficient to Solidity (Ct/σ) Ratios

Authors: K. K. Saijaand, K. Prabhakaran Nair

Abstract:

This study aims to determine change in optimal lo-cations of dual trailing-edge flaps for various thrust coefficient to solidity (Ct /σ) ratios of helicopter to achieve minimum hub vibration levels, with low penalty in terms of required trailing-edge flap control power. Polynomial response functions are used to approximate hub vibration and flap power objective functions. Single objective and multi-objective optimization is carried with the objective of minimizing hub vibration and flap power. The optimization results shows that the inboard flap location at low Ct/σ ratio move farther from the baseline value and at high Ct/σ ratio move towards the root of the blade for minimizing hub vibration.

Keywords: helicopter rotor, trailing-edge flap, thrust coefficient to solidity (Ct /σ) ratio, optimization

Procedia PDF Downloads 449