Search results for: arthroscopy knee
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 277

Search results for: arthroscopy knee

67 Survey of Epidemiology and Mechanisms of Badminton Injury Using Medical Check-Up and Questionnaire of School Age Badminton Players

Authors: Xiao Zhou, Kazuhiro Imai, Xiaoxuan Liu

Abstract:

Badminton is one type of racket sports that requires repetitive overhead motion, with the shoulder in abduction/external rotation and requires players to perform jumps, lunges, and quick directional changes. These characteristics could be stressful for body regions that may cause badminton injuries. Regarding racket players including badminton players, there have not been any studies that have utilized medical check-up to evaluate epidemiology and mechanism of injuries. In addition, epidemiology of badminton injury in school age badminton players is unknown. The first purpose of this study was to investigate the badminton injuries, physical fitness parameters, and intensity of shoulder pain using medical check-up so that the mechanisms of shoulder injuries might be revealed. The second purpose of this study was to survey the distribution of badminton injuries in elementary school age players so that injury prevention can be implemented as early as possible. The results of this study revealed that shoulder pain occurred in all players, and present shoulder pain players had smaller weight, greater shoulder external rotation (ER) gain, significantly thinner circumference of upper limbs and greater trunk extension. Identifying players with specific of these factors may enhance the prevention of badminton injury. This study also shows that there are high incidences of knee, ankle, plantar, and shoulder injury or pain in elementary school age badminton players. Injury prevention program might be implemented for elementary school age players.

Keywords: badminton injury, epidemiology, medical check-up, school age players

Procedia PDF Downloads 108
66 Development of an Auxetic Tissue Implant

Authors: Sukhwinder K. Bhullar, M. B. G. Jun

Abstract:

The developments in biomedical industry have demanded the development of biocompatible, high performance materials to meet higher engineering specifications. The general requirements of such materials are to provide a combination of high stiffness and strength with significant weight savings, resistance to corrosion, chemical resistance, low maintenance, and reduced costs. Auxetic materials which come under the category of smart materials offer huge potential through measured enhancements in mechanical properties. Unique deformation mechanism, providing cushioning on indentation, automatically adjustable with its strength and thickness in response to forces and having memory returns to its neutral state on dissipation of stresses make them good candidate in biomedical industry. As simple extension and compression of tissues is of fundamental importance in biomechanics, therefore, to study the elastic behaviour of auxetic soft tissues implant is targeted in this paper. Therefore development and characterization of auxetic soft tissue implant is studied in this paper. This represents a real life configuration where soft tissue such as meniscus in knee replacement, ligaments and tendons often are taken as transversely isotropic. Further, as composition of alternating polydisperse blocks of soft and stiff segments combined with excellent biocompatibility make polyurethanes one of the most promising synthetic biomaterials. Hence selecting auxetic polyurathylene foam functional characterization is performed and compared with conventional polyurathylene foam.

Keywords: auxetic materials, deformation mechanism, enhanced mechanical properties, soft tissues

Procedia PDF Downloads 440
65 Pressure Relief in Prosthetic Sockets through Hole Implementation Using Different Materials

Authors: Gabi N. Nehme

Abstract:

Below-knee amputees commonly experience asymmetrical gait patterns. It is generally believed that ischemia is related to the formation of pressure sores due to uneven distribution of forces. Micro-vascular responses can reveal local malnutrition. Changes in local skin blood supply under various external loading conditions have been studied for a number of years. Radionuclide clearance, photo-plethysmography, trans-cutaneous oxygen tension along with other studies showed that the blood supply would be influenced by the epidermal forces, and the rate and the amount of blood supply would decrease with increased epidermal loads being shear forces or normal forces. Several cases of socket designs were investigated using Finite Element Model (FEM) and Design of Experiment (DOE) to increase flexibility and minimize the pressure at the limb/socket interface using ultra high molecular weight polyethylene (UHMWPE) and polyamide 6 (PA6) or Duraform. The pressure reliefs at designated areas where reducing thickness is involved are seen to be critical in determination of amputees’ comfort and are very important to clinical applications. Implementing a hole between the Patellar Tendon (PT) and Distal Tibia (DT) would decrease stiffness and increase prosthesis range of motion where flexibility is needed. In addition, displacement and prosthetic energy storage increased without compromising mechanical efficiency and prosthetic design integrity.

Keywords: patellar tendon, distal tibia, prosthetic socket relief areas, hole implementation

Procedia PDF Downloads 386
64 Long-Term Sitting Posture Identifier Connected with Cloud Service

Authors: Manikandan S. P., Sharmila N.

Abstract:

Pain in the neck, intermediate and anterior, and even low back may occur in one or more locations. Numerous factors can lead to back discomfort, which can manifest into sensations in the other parts of your body. Up to 80% of people will have low back problems at a certain stage of their lives, making spine-related pain a highly prevalent ailment. Roughly twice as commonly as neck pain, low back discomfort also happens about as often as knee pain. According to current studies, using digital devices for extended periods of time and poor sitting posture are the main causes of neck and low back pain. There are numerous monitoring techniques provided to enhance the sitting posture for the aforementioned problems. A sophisticated technique to monitor the extended sitting position is suggested in this research based on this problem. The system is made up of an inertial measurement unit, a T-shirt, an Arduino board, a buzzer, and a mobile app with cloud services. Based on the anatomical position of the spinal cord, the inertial measurement unit was positioned on the inner back side of the T-shirt. The IMU (inertial measurement unit) sensor will evaluate the hip position, imbalanced shoulder, and bending angle. Based on the output provided by the IMU, the data will be analyzed by Arduino, supplied through the cloud, and shared with a mobile app for continuous monitoring. The buzzer will sound if the measured data is mismatched with the human body's natural position. The implementation and data prediction with design to identify balanced and unbalanced posture using a posture monitoring t-shirt will be further discussed in this research article.

Keywords: IMU, posture, IOT, textile

Procedia PDF Downloads 48
63 Effect of Different Muscle Contraction Mode on the Expression of Myostatin, IGF-1, and PGC-1 Alpha Family Members in Human Vastus Lateralis Muscle

Authors: Pejman Taghibeikzadehbadr

Abstract:

Muscle contraction stimulates a transient change of myogenic factors, partly related to the mode of contractions. Here, we assessed the response of Insulin-like growth factor 1Ea (IGF-1Ea), Insulin-like growth factor 1Eb (IGF-1Eb), Insulin-like growth factor 1Ec (IGF-1Ec), Peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC1α-1), Peroxisome proliferator-activated receptor gamma coactivator 4-alpha (PGC1α-4), and myostatin to the eccentric Vs the concentric contraction in human skeletal muscle. Ten healthy males were performed an acute eccentric and concentric exercise bout (n = 5 per group). For each contraction type, participants performed 12 sets of 10 repetitions knee extension by the dominant leg. Baseline and post-exercise muscle biopsy were taken 4 weeks before and immediately after experimental sessions from Vastus Lateralis muscle. Genes expression was measured by real-time PCR technique. There was a significant increase in PGC1α-1, PGC1α-4, IGF-1Ea and, IGF-1Eb mRNA after concentric contraction (p ≤ 0.05), while the PGC1α-4 and IGF-1Ec significantly increased after eccentric contraction (p ≤ 0.05). It is intriguing to highlight that; no significant differences between groups were evident for changes in any variables following exercise bouts (p ≥ 0.05). Our results found that concentric and eccentric contractions presented different responses in PGC1α-1, IGF-1Ea, IGF-1Eb, and IGF-1Ec mRNA. However, a similar significant increase in mRNA content was observed in PGC1α-4. Further, no apparent differences could be found between the response of genes to eccentric and concentric contraction.

Keywords: eccentric contraction, concentric contraction, gene expression, PGC-1 alpha, IGF-1 Myostatin

Procedia PDF Downloads 138
62 Comparing Effects of Supervised Exercise Therapy versus Home-Based Exercise Therapy on Low Back Pain Severity, Muscle Strength and Anthropometric Parameters in Patients with Nonspecific Chronic Low Back Pain

Authors: Haleh Dadgostar, Faramarz Akbari, Hosien Vahid Tari, Masoud Solaymani-Dodaran, Mohammad Razi

Abstract:

Introduction: There are a number of exercises-protocols have been applied to improve low back pain. We compared the effect of supervised exercise therapy and home-based exercise therapy among patients with nonspecific chronic low back pain. Methods: 70 patients with nonspecific chronic low back pain were randomly (using a random number generator, excel) divided into two groups to compare the effects of two types of exercise therapy. After a common educational session to learn how to live with low back pain as well as to use core training protocols to strengthen the muscles, the subjects were randomly assigned to follow supervised exercise therapy (n = 31) or home-based exercise therapy (n = 34) for 20 weeks. Results: Although both types of exercise programs resulted in reduced pain, this factor decreased more significantly in supervised exercise program. All scores of fitness improved significantly in supervised exercise group. But only knee extensor strength score was increased in the home base exercise group. Conclusion: Comparing between two types of exercise, supervised group exercise showed more effective than the other one. Reduction in low back pain severity and improvement in muscle flexibility and strength can be more achieved by using a 20-week supervised exercise program compared to the home-based exercise program in patients with nonspecific chronic low back pain.

Keywords: low back pain, anthropometric parameters, supervised exercise therapy, home-based exercise therapy

Procedia PDF Downloads 296
61 Mathematical Modelling and AI-Based Degradation Analysis of the Second-Life Lithium-Ion Battery Packs for Stationary Applications

Authors: Farhad Salek, Shahaboddin Resalati

Abstract:

The production of electric vehicles (EVs) featuring lithium-ion battery technology has substantially escalated over the past decade, demonstrating a steady and persistent upward trajectory. The imminent retirement of electric vehicle (EV) batteries after approximately eight years underscores the critical need for their redirection towards recycling, a task complicated by the current inadequacy of recycling infrastructures globally. A potential solution for such concerns involves extending the operational lifespan of electric vehicle (EV) batteries through their utilization in stationary energy storage systems during secondary applications. Such adoptions, however, require addressing the safety concerns associated with batteries’ knee points and thermal runaways. This paper develops an accurate mathematical model representative of the second-life battery packs from a cell-to-pack scale using an equivalent circuit model (ECM) methodology. Neural network algorithms are employed to forecast the degradation parameters based on the EV batteries' aging history to develop a degradation model. The degradation model is integrated with the ECM to reflect the impacts of the cycle aging mechanism on battery parameters during operation. The developed model is tested under real-life load profiles to evaluate the life span of the batteries in various operating conditions. The methodology and the algorithms introduced in this paper can be considered the basis for Battery Management System (BMS) design and techno-economic analysis of such technologies.

Keywords: second life battery, electric vehicles, degradation, neural network

Procedia PDF Downloads 26
60 Effect of Sintering Time and Porosity on Microstructure, Mechanical and Corrosion Properties of Ti6Al15Mo Alloy for Implant Applications

Authors: Jyotsna Gupta, S. Ghosh, S. Aravindan

Abstract:

The requirement of artificial prostheses (such as hip and knee joints) has increased with time. Many researchers are working to develop new implants with improved properties such as excellent biocompatibility with no tissue reactions, corrosion resistance in body fluid, high yield strength and low elastic modulus. Further, the morphological properties of the artificial implants should also match with that of the human bone so that cell adhesion, proliferation and transportation of the minerals and nutrition through body fluid can be obtained. Present study attempts to make porous Ti6Al15Mo alloys through powder metallurgy route using space holder technique. The alloy consists of 6wt% of Al which was taken as α phase stabilizer and 15wt% Mo was taken as β phase stabilizer with theoretical density 4.708. Ammonium hydrogen carbonate is used as a space holder in order to generate the porosity. The porosity of these fabricated porous alloys was controlled by adding the 0, 50, 70 vol.% of the space holder content. Three phases were found in the microstructure: α, α_2 and β phase of titanium. Kirkendall pores are observed to be decreased with increase of holding time during sintering and parallelly compressive strength and elastic modulus value increased slightly. Compressive strength and elastic modulus of porous Ti-6Al-15Mo alloy (1.17 g/cm3 density) is found to be suitable for cancellous bone. Released ions from Ti-6Al-15Mo alloy are far below from the permissible limits in human body.

Keywords: bone implant, powder metallurgy, sintering time, Ti-6Al-15Mo

Procedia PDF Downloads 120
59 Injury Pattern of Field Hockey Players at Different Field Position during Game and Practice

Authors: Sujay Bisht

Abstract:

The purpose of the study was to assess and examines the pattern of injury among the field hockey players at different field position during practice & game. It was hypothesized that the backfield might have the height rate of injury, followed by midfield. Methods: university level and national level male field hockey (N=60) are selected as a subject and requested to respond an anon questionnaire. Personal characteristics of each and individual players were also collected like (age, height, weight); field hockey professional information (level of play, year of experience, playing surface); players injury history (site, types, cause etc). The rates of injury per athlete per year were also calculated. Result: Around half of the injury occurred were to the lower limbs (49%) followed by head and face (30%), upper limbs (19%) and torso region (2%). Injuries included concussion, wounds, broken nose, ligament sprain, dislocation, fracture, and muscles strain and knee injury. The ligament sprain is the highest rate (40%) among the other types of injuries. After investigation and evaluation backfield players had the highest rate of risk of injury (1.10 injury/athletes-year) followed by midfield players (0.70 injury/athlete-year), forward players (0.45 injury/athlete-year) & goalkeeper was (0.37 injury/athlete-year). Conclusion: Due to the different field position the pattern & rate of injury were different. After evaluation, lower limbs had the highest rate of injury followed by head and face, upper limbs and torso respectively. It also revealed that not only there is a difference in the rate of injury between playing the position, but also in the types of injury sustain at a different position.

Keywords: trauma, sprain, strain, astroturf, acute injury

Procedia PDF Downloads 196
58 Computer Aided Shoulder Prosthesis Design and Manufacturing

Authors: Didem Venus Yildiz, Murat Hocaoglu, Murat Dursun, Taner Akkan

Abstract:

The shoulder joint is a more complex structure than the hip or knee joints. In addition to the overall complexity of the shoulder joint, two different factors influence the insufficient outcome of shoulder replacement: the shoulder prosthesis design is far from fully developed and it is difficult to place these shoulder prosthesis due to shoulder anatomy. The glenohumeral joint is the most complex joint of the human shoulder. There are various treatments for shoulder failures such as total shoulder arthroplasty, reverse total shoulder arthroplasty. Due to its reverse design than normal shoulder anatomy, reverse total shoulder arthroplasty has different physiological and biomechanical properties. Post-operative achievement of this arthroplasty is depend on improved design of reverse total shoulder prosthesis. Designation achievement can be increased by several biomechanical and computational analysis. In this study, data of human both shoulders with right side fracture was collected by 3D Computer Tomography (CT) machine in dicom format. This data transferred to 3D medical image processing software (Mimics Materilise, Leuven, Belgium) to reconstruct patient’s left and right shoulders’ bones geometry. Provided 3D geometry model of the fractured shoulder was used to constitute of reverse total shoulder prosthesis by 3-matic software. Finite element (FE) analysis was conducted for comparison of intact shoulder and prosthetic shoulder in terms of stress distribution and displacements. Body weight physiological reaction force of 800 N loads was applied. Resultant values of FE analysis was compared for both shoulders. The analysis of the performance of the reverse shoulder prosthesis could enhance the knowledge of the prosthetic design.

Keywords: reverse shoulder prosthesis, biomechanics, finite element analysis, 3D printing

Procedia PDF Downloads 130
57 Body Mass Components in Young Soccer Players

Authors: Elizabeta Sivevska, Sunchica Petrovska, Vaska Antevska, Lidija Todorovska, Sanja Manchevska, Beti Dejanova, Ivanka Karagjozova, Jasmina Pluncevic Gligoroska

Abstract:

Introduction: Body composition plays an important role in the selection of young soccer players and it is associated with their successful performance. The most commonly used model of body composition divides the body into two compartments: fat components and fat-free mass (muscular and bone components). The aims of the study were to determine the body composition parameters of young male soccer players and to show the differences in age groups. Material and methods: A sample of 52 young male soccer players, with an age span from 9 to 14 years were divided into two groups according to the age (group 1 aged 9 to 12 years and group 2 aged 12 to 14 years). Anthropometric measurements were taken according to the method of Mateigka. The following measurements were made: body weight, body height, circumferences (arm, forearm, thigh and calf), diameters (elbow, knee, wrist, ankle) and skinfold thickness (biceps, triceps, thigh, leg, chest, abdomen). The measurements were used in Mateigka’s equations. Results: Body mass components were analyzed as absolute values (in kilograms) and as percentage values: the muscular component (MC kg and MC%), the bone component (BCkg and BC%) and the body fat (BFkg and BF%). The group up to 12 years showed the following mean values of the analyzed parameters: MM=21.5kg; MM%=46.3%; BC=8.1kg; BC%=19.1%; BF= 6.3kg; BF%= 15.7%. The second group aged 12-14 year had mean values of body composition parameters as follows: MM=25.6 kg; MM%=48.2%; BC = 11.4 kg; BC%=21.6%; BF= 8.5 kg; BF%= 14. 7%. Conclusions: The young soccer players aged 12 up to 14 years who are in the pre-pubertal phase of growth and development had higher bone component (p<0.05) compared to younger players. There is no significant difference in muscular and fat body component between the two groups of young soccer players.

Keywords: body composition, young soccer players, body fat, fat-free mass

Procedia PDF Downloads 427
56 Use of Triclosan-Coated Sutures Led to Cost Saving in Public and Private Setting in India across Five Surgical Categories: An Economical Model Assessment

Authors: Anish Desai, Reshmi Pillai, Nilesh Mahajan, Hitesh Chopra, Vishal Mahajan, Ajay Grover, Ashish Kohli

Abstract:

Surgical Site Infection (SSI) is hospital acquired infection of growing concern. This study presents the efficacy and cost-effectiveness of triclosan-coated suture, in reducing the burden of SSI in India. Methodology: A systematic literature search was conducted for economic burden (1998-2018) of SSI and efficacy of triclosan-coated sutures (TCS) vs. non-coated sutures (NCS) (2000-2018). PubMed Medline and EMBASE indexed articles were searched using Mesh terms or Emtree. Decision tree analysis was used to calculate, the cost difference between TCS and NCS at private and public hospitals, respectively for 7 surgical procedures. Results: The SSI range from low to high for Caesarean section (C-section), Laparoscopic hysterectomy (L-hysterectomy), Open Hernia (O-Hernia), Laparoscopic Cholecystectomy (L-Cholecystectomy), Coronary artery bypass graft (CABG), Total knee replacement (TKR), and Mastectomy were (3.77 to 24.2%), (2.28 to 11.7%), (1.75 to 60%), (1.71 to 25.58%), (1.6 to 18.86%), (1.74 to 12.5%), and (5.56 to 25%), respectively. The incremental cost (%) of TCS ranged 0.1%-0.01% in private and from 0.9%-0.09% at public hospitals across all surgical procedures. Cost savings at median efficacy & SSI risk was 6.52%, 5.07 %, 11.39%, 9.63%, 3.62%, 2.71%, 9.41% for C-section, L-hysterectomy, O-Hernia, L-Cholecystectomy, CABG, TKR, and Mastectomy in private and 8.79%, 4.99%, 12.67%, 10.58%, 3.32%, 2.35%, 11.83% in public hospital, respectively. Efficacy of TCS and SSI incidence in a particular surgical procedure were important determinants of cost savings using one-way sensitivity analysis. Conclusion: TCS suture led to cost savings across all 7 surgeries in both private and public hospitals in India.

Keywords: cost Savings, non-coated sutures, surgical site infection, triclosan-coated sutures

Procedia PDF Downloads 368
55 Quantification of Soft Tissue Artefacts Using Motion Capture Data and Ultrasound Depth Measurements

Authors: Azadeh Rouhandeh, Chris Joslin, Zhen Qu, Yuu Ono

Abstract:

The centre of rotation of the hip joint is needed for an accurate simulation of the joint performance in many applications such as pre-operative planning simulation, human gait analysis, and hip joint disorders. In human movement analysis, the hip joint center can be estimated using a functional method based on the relative motion of the femur to pelvis measured using reflective markers attached to the skin surface. The principal source of errors in estimation of hip joint centre location using functional methods is soft tissue artefacts due to the relative motion between the markers and bone. One of the main objectives in human movement analysis is the assessment of soft tissue artefact as the accuracy of functional methods depends upon it. Various studies have described the movement of soft tissue artefact invasively, such as intra-cortical pins, external fixators, percutaneous skeletal trackers, and Roentgen photogrammetry. The goal of this study is to present a non-invasive method to assess the displacements of the markers relative to the underlying bone using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction (all with knee extended) of the hip joint. Results show that the artefact skin marker displacements are non-linear and larger in areas closer to the hip joint. Also marker displacements are dependent on the movement type and relatively larger in abduction movement. The quantification of soft tissue artefacts can be used as a basis for a correction procedure for hip joint kinematics.

Keywords: hip joint center, motion capture, soft tissue artefact, ultrasound depth measurement

Procedia PDF Downloads 254
54 A Study of Influence of Freezing on Mechanical Properties of Tendon Fascicles

Authors: Martyna Ekiert, Andrzej Mlyniec

Abstract:

Tendons are the biological structures, which primary function is to transfer force generated by muscles to the bones. Unfortunately, damages of tendons are also one of the most common injuries of the human musculoskeletal system. For the most severe cases of tendon rupture, such as the tear of calcaneus tendon or anterior cruciate ligament of the knee, a surgical procedure is the only possible way of full recovery. Tendons used as biological grafts are usually subjected to the process of deep freezing and subsequent thawing. This, in particular for multiple freezing/thawing cycles, may result in changes of tendon internal structure causing deterioration of mechanical properties of the tissue. Therefore, studies on the influence of freezing on tendons biomechanics, including internal water content in soft tissue, seems to be greatly needed. An experimental study of the influence of freezing on mechanical properties of the tendon was performed on fascicles samples dissected form bovine flexor tendons. The preparation procedure was performed with the presence of 0.9% saline solution in order to prevent an excessive tissue drying. All prepared samples were subjected to the different number of freezing/thawing cycles. For freezing part of the protocol we used -80°C temperature while for slow thawing we used fridge temperature (4°C) combined with equalizing temperatures in the standard state (25°C). After final thawing, the mechanical properties of each sample was examined using cyclic loading test. Our results may contribute for better understanding of negative effects of soft tissues freezing, resulting from abnormal thermal expansion of water. This also may help to determine the limit of freezing/thawing cycles disqualifying tissue for surgical purposes and thus help optimize tissues storage conditions.

Keywords: freezing, soft tissue, tendon, bovine fascicles

Procedia PDF Downloads 185
53 Lateral Sural Artery Perforators: A Cadaveric Dissection Study to Assess Perforator Surface Anatomy Variability and Average Pedicle Length for Flap Reconstruction

Authors: L. Sun, O. Bloom, K. Anderson

Abstract:

The medial and lateral sural artery perforator flaps (MSAP and LSAP, respectively) are two recently described flaps that are less commonly used in lower limb trauma reconstructive surgeries compared to flaps such as the anterolateral thigh (ALT) flap or the gastrocnemius flap. The LSAP flap has several theoretical benefits over the MSAP, including the ability to be sensate and being more easily manoeuvred into position as a local flap for coverage of lateral knee or leg defects. It is less commonly used in part due to a lack of documented studies of the anatomical reliability of the perforator, and an unquantified average length of the pedicle used for microsurgical anastomosis (if used as a free flap) or flap rotation (if used as a pedicled flap). It has been shown to have significantly lower donor site morbidity compared to other flaps such as the ALT, due to the decreased need for intramuscular dissection and resulting in less muscle loss at the donor site. 11 cadaveric lower limbs were dissected, with a mean of 1.6 perforators per leg, with an average pedicle length of 45mm to the sural artery and 70mm to the popliteal artery. While the majority of perforating arteries lay close to the midline (average of 19mm lateral to the midline), there were patients whose artery was significantly lateral and would have been likely injured by the initial incision during an operation. Adding to the literature base of documented LSAP dissections provides a greater understanding of the anatomical basis of these perforator flaps, and the authors hope this will establish them as a more commonly used and discussed option when managing complicated lower limb trauma requiring soft tissue reconstruction.

Keywords: cadaveric, dissection, lateral, perforator flap, sural artery, surface anatomy

Procedia PDF Downloads 129
52 Evaluation of Joint Contact Forces and Muscle Forces in the Subjects with Non-Specific Low Back Pain

Authors: Mohammad Taghi Karimi, Maryam Hasan Zahraee

Abstract:

Background: Low back pain (LBP) is a common health and socioeconomic problem, especially the chronic one. The joint contact force is an important parameter during walking which increases the incidence of injury and degenerative joint disease. To our best knowledge, there are not enough evidences in literature on the muscular forces and joint contact forces in subjects with low back pain. Purpose: The main hypothesis associated with this research was that joint contact force of L4/L5 of non-specific chronic low back pain subjects was the same as that of normal. Therefore, the aim of this study was to determine the joint contact force difference between non-specific chronic low back pain and normal subjects. Method: This was an experimental-comparative study. 20 normal subjects and 20 non-specific chronic low back pain patients were recruited in this study. Qualysis motion analysis system and a Kistler force plate were used to collect the motions and the force applied on the leg, respectively. OpenSimm software used to determine joint contact force and muscle forces in this study. Some parameters such as force applied on the legs (pelvis), kinematic of hip and pelvic, peaks of muscles, force of trunk musculature and joint contact force of L5/S1 were used for further analysis. Differences between mean values of all data were measured using two-sample t-test among the subjects. Results: The force produced by Semitendinosus, Biceps Femoris, and Adductor muscles were significantly different between low back pain and normal subjects. Moreover, the mean value of breaking component of the force of the knee joint increased significantly in low back pain subjects, besides a significant decrease in mean value of the vertical component of joint reaction force compared to the normal ones. Conclusions: The forces produced by the trunk and pelvic muscles, and joint contact forces differ significantly between low back pain and normal subjects. It seems that those with non-specific chronic low back pain use trunk muscles more than normal subjects to stabilize the pelvic during walking.

Keywords: low back pain, joint contact force, kinetic, muscle force

Procedia PDF Downloads 209
51 Effect of Various Durations of Type 2 Diabetes on Muscle Performance

Authors: Santosh Kumar Yadav, Shobha Keswani, Nishat Quddus, Sohrab Ahmad Khan, Zuheb Ahmad Shiddiqui, Varsha Chorsiya

Abstract:

Introduction: Early onset diabetes is more aggressive than the late onset diabetes. Diabetic individual has a greater spectrum of life period to suffer from its damage, complications, and long-term disability. This study aimed at assessing knee joint muscle performance under various durations of diabetes. Method and Materials: A total of 30 diabetic subjects (18 male and 12 females) without diabetic neuropathy were included for the study. They were divided into three groups with 5 years, 10 years and 15 years of duration of disease each. Muscle performance was evaluated through strength and flexibility. Peak torque for quadriceps muscle was measured using isokinetic dynamometer. Flexibility for quadriceps and hamstring muscles were measured through Ducan’s Elys test and 90/90 test. Results: The result showed significant difference in muscle strength (p<0.05), flexibility (p≤0.05) between groups. Discussion: Optimal muscle strength and flexibility are vital for musculoskeletal health and functional independence. Conclusion: The reduced muscle performance and functional impairment in nonneuropathic diabetic patients suggest that other mechanism besides neuropathy that contribute to altered biomechanics. These findings of this study project early management of these altered parameters through disease-specific physical therapy and assessment-based intervention. Clinical Relevance: Managing disability is more costly than managing disease. Prompt and timely identification and management strategy can dramatically reduce the cost of care for diabetic patients.

Keywords: muscle flexibility, muscle performance, muscle torque, type 2 diabetes

Procedia PDF Downloads 304
50 Retrospective/Prospective Analysis of Guideline Implementation and Transfusion Rates

Authors: B. Kenny

Abstract:

The complications associated with transfusions are well documented, with the serious hazards of transfusion (SHOT) reporting system continuing to report deaths and serious morbidity due to the transfusion of allogenic blood. Many different sources including the TRICC trial, NHMRC and Cochrane recommending similar transfusion triggers/guidelines. Recent studies found the rate of infection (deep infection, wound infection, chest infection, urinary tract infection, and others) were purely a dose response relationship, increasing the Relative Risk by 3.44. It was also noted that each transfused patient stayed in hospital for one additional day. We hypothesise that providing an approved/standardised, guideline with a graphical summary of decision pathways for anaemic patients will reduce unnecessary transfusions. We retrospectively assessed patients undergoing primary knee or hip arthroplasties over a 4 year period, 1459 patients. Of these, 339 (23.24%) patients received allogenic blood transfusions and 858 units of blood were transfused, 9.14% of patients transfused had haemoglobin levels above 100 g/L, 7.67% of patients were transfused without knowing the haemoglobin level, 24 hours prior to transfusion initiation and 4.5% had possible transfusion reactions. Overall, 17% of allogenic transfusions topatients admitted to the Orthopaedic department within a 4 year period were outside NHMRC and Cochrane guidelines/recommendations. If our transfusion frequency is compared with that of other authors/hospitals, transfusion rates are consistently being high. We subsequently implemented a simple guideline for transfusion initiation. This guideline was then assessed. We found the transfusion rate post transfusion implementation to be significantly lower, without increase in patient morbidity or mortalitiy, p <0.001). Transfusion rates and patient outcome can be optimized by a simple graphical aid for decision making.

Keywords: transfusion, morbidity, mortality, neck of femur, fracture, arthroplasty, rehabilitation

Procedia PDF Downloads 213
49 The Endocrinology of Obesity and Dejenerative Joint Disease

Authors: Kebret Kebede, Anthony Scinta

Abstract:

Obesity is the most prevalent global problem that continues to rise at alarming rates both in the industrialized and developing countries. Adipose tissue is an endocrine tissue that secretes numerous chemical signals, hormones, lipids, cytokines and coagulation factors as well as prompting insulin resistance which is a primary contributor to Type II Diabetes- one of its most common adverse effects on health. Other hormones whose levels are linked to obesity and nutritional state are leptin, IGF-1, and adiponectin. Several studies indicate that obesity is the leading cause of high levels of cholesterol that leads to fatty liver disease, gallstones, hypertension, increased risk for cancer and degenerative joint disease that primarily affects the weight bearing joints of the lower extremities. The activation of inflammatory pathways promotes synovial pathology that results in accelerated degeneration of the joints. The study examines the prevalence of obesity in the US female population in comparison to that of the developing world and its emergence as a significant and potentially modifiable risk factor in degenerative disease of the hip and knee joints that has resulted in staggering healthcare cost. Studies have shown that as the prevalence of obesity rises, we continue to see a rise in degenerative joint disease. The percentage of arthritis cases linked directly to obesity has risen from 3 percent in 1971 to 18 percent in 2002. A person with obesity is around 60 percent more likely to develop arthritis than someone of normal body weight. In women, obesity is associated with increased mortality from breast, cervical, endometrial and ovarian cancer that may accompany debilitating joint diseases and restricted mobility.

Keywords: obesity, endocrine, degenerative, mortality, joint diseases, cancer, debilitating, mobility

Procedia PDF Downloads 410
48 Surgical Management of Distal Femur Fracture Using Locking Compression Plate: Our Experience in a Rural Tertiary Care Centre in India

Authors: Pagadaplly Girish, P. V. Manohar

Abstract:

Introduction: Management of distal femur fractures is challenging. Recently, treatment has evolved towards indirect reduction and minimally invasive techniques. Objectives: To assess the fracture union and functional outcome following open reduction and internal fixation of distal femur fractures with locking compression plate and to achieve restoration of the anatomical alignment of fracture fragments and stable internal fixation. Methodology: Patients with distal femur fracture treated by locking compression during Oct 2011 to April 2013 were assessed prospectively. Patients below 18 years and those with neuro-vascular deficits were excluded. Age, sex of the patient, type of fracture, mechanism of injury, type of implant used, operative time and postoperative complications were analysed. The Neer’s scale was used to assess the outcome of the patients. Results: The total number of patients was 30; 28 males and 2 females; mean age was 41.53 years. Road traffic accidents were the major causes of injury followed by falls. The average duration of hospital stay was 21.3 days. The overall complication rate note was 23.33%. The mean range of movement around the knee joint after 6 months of follow-up was 114.330. The average time for the radiological union was 14 weeks. Excellent to good results were noted in 26 patients (86.6%) and average to poor results were observed in 4 (13.33%) patients. Conclusions: The locking compression plate gives a rigid fixation for the fracture. It also provides a good purchase in osteoporotic bones. LCP is simple and a reliable implant appropriate for fixation of femoral fractures with promising results.

Keywords: distal femur fractures, locking compression plate, Neer’s criteria, neuro-vascular deficits

Procedia PDF Downloads 218
47 Sol-Gel Coated Fabric for Controlled Release of Mosquito Repellent

Authors: Bhaskar M. Murai, Neeraj Banchor, Ishveen Chabbra, Madhusudhan Nadgir, S. Vidhya

Abstract:

Sol-gel technology combined with electronics and biochemistry helps to overcome the problems caused by mosquitoes by developing a portable, low-cost device which enables controlled release of trapped compound inside it. It is a wet-chemical technique which is used primarily for fabrication of silicate gel which is usually allowed to dry as per requirement. The outcome is solid rock hard material which is porous and has lots of applications in different fields. Taking porosity as a key factor, allethrin a naturally occurring synthetic compound with molecular mass 302.40 was entrapped inside the sol-gel matrix as a dopant. Allethrin is commonly used as an insecticide and is a key ingredient in commercially available mosquitoes repellent in Asian and subtropical countries. It has low toxicity for humans and birds, and are used in many household insecticides such as RAID as well as mosquito coils. They are however highly toxic to fish and bees. Insects subject to its exposure become paralyzed (nervous system effect) before dying. They are also used as an ultra-low volume spray for outdoor mosquito control. Therefore, there is a need for controlled release of allethrin in the environment. For controlled release of allethrin from sol-gel matrix, its (allethrin) we utilized temperature based controlled evaporation through porous sol-gel. Different types of fabric like cotton, Terri-cotton, polyester, surgical cap, knee-cap etc are studied and the best with maximum absorption capacity is selected to hold the sol-gel matrix with maximum quantity. For sol-gel coating 2 x 2cm cloth pieces are dipped in sol-gel solution for 10 minutes and by calculating the weight difference we concluded that Terri cotton is best suitable for our project. An electronic circuit with heating plate is developed in to test the controlled release of compound. An oscillatory circuit is used to produce the required heat.

Keywords: sol-gel, allethrin, TEOS, biochemistry

Procedia PDF Downloads 345
46 Symptoms Experiences among Thai Adults with Chronic Illnesses: A Study in an Urban Community Area of Bangkok

Authors: Orapan Thosingha, Tassana Boontong, Prapa Yuttatri, Vilaivan Thongcharoen, Soparn Potaya, Mattika Chaichan, Chanin Chakkrapopyodhin, Khwanthida Phimphakarn, Taddao Nabnean

Abstract:

This research aimed to explore symptom experiences among Thai adults with chronic illnesses living in an urban community area of Bangkok. The sample was 670 adults with ages ranging from 20-59 years. The majority of them (65.2%) had more than one disease. Hypertension, dyslipidemia, and diabetes were the first three diseases among them. About 58% were female, and 51.1 % stayed with their couples. The studied sample had relatively low socioeconomic status; 33.7% were wage workers, 15.2% were street vendors, and 10.4% were unemployed. About 54 % had family incomes less than 10,000 baht (300 US Dollars) per month, and 41.6% addressed that their incomes were not adequate for daily living. Although the majority of them (63.7%) did not have to pay for hospital visits, they still had to pay for public transportation and could not earn a wage or any income on the hospital visit day. The first three physical symptoms they experienced were knee pain (60.5%) due to being overweight, headache (47.0%), and insomnia (44.6%). About 45% stated that their incomes decreased after having chronic illnesses and 37.2% expressed that having lower incomes affected their living, 34.5% perceived being a burden, and 34.3% regret about depending on others. It can be concluded that adults with low socioeconomic status who experienced chronic illnesses and resided in an urban community area had complex needs. While caring for them, nurses should pay attention not only to a disease-related domain but also to a social-related domain. Reached-out clinics led by professional nurses who are well-prepared for primary medical care and home visit are strongly recommended. National Health Security Office should adopt this policy and develop an action plan to serve the needs of chronically ill adults with low socioeconomic status.

Keywords: chronic illnesses, urban community, socioeconomic status, symptom experiences, low incomes

Procedia PDF Downloads 78
45 Phenotypic Characterisation of Bapedi Sheep Breed

Authors: Fhulufhelo Ramukhithi, Kgothatso Masethe, Tlou Chokoe, Ayanda Maqhashu, Julius Sebei, Tshililo Raphulu, Joseph Mugwabana

Abstract:

Phenotypic characterisation ensures that the physical appearance of an animal is well documented. The information provided by this phenotypic characterisation study is important for planning management and the use of animal genetic resources. The aim of this study was to characterise the phenotypic characteristics of Bapedi sheep. Bapedi sheep are at risk of extinction like most of the indigenous breeds. As a result, a total of 196 Bapedi ewes and 35 rams were used. Phenotypic-qualitative characteristics were evaluated through visual appraisal. Phenotypic-quantitative characteristics such as body parts measurements were obtained using a flexible tape (cm), while body weight were obtained by using a weighing scale (kg). Bapedi rams (97 %) had higher satisfactory body condition when compared to ewes (75 %). A higher proportion of Bapedi sheep that did not have ticks observed (ewes = 87 % and rams = 91 %). Brown and white colour combination (head x body) was dominating in Bapedi sheep (80 % ewes and 91 % rams). Bapedi ewes did not have any horns; however, 3 % of rams had them. Bapedi sheep had a higher proportion of brown eyes, moderate neck, stiff sideways ears and normal front legs. Bapedi rams had a higher proportion of well-balanced and good attached testicles. Bapedi ewes had average (45 %), small (40 %) and big udders (15 %). Bapedi rams had a significantly higher body weight, height, depth, hearth girth circumference, rump width, hind leg width and length compared to ewes. However, both Bapedi rams and ewes had similar age, body condition score, tail length, length below hock and knee. In conclusion, Bapedi sheep had a higher satisfactory body condition and brown and white colour combination. Some of Bapedi rams’ quantitative characteristics were higher compared to ewes.

Keywords: extinction, indigenous, phenotypic, smallstock

Procedia PDF Downloads 182
44 The Effects of Impact Forces and Kinematics of Two Different Stance Position at Straight Punch Techniques in Boxing

Authors: Bergun Meric Bingul, Cigdem Bulgan, Ozlem Tore, Mensure Aydin, Erdal Bal

Abstract:

The aim of the study was to compare the effects of impact forces and some kinematic parameters with two different straight punch stance positions in boxing. 9 elite boxing athletes from the Turkish National Team (mean age± SD 19.33±2.11 years, mean height 174.22±3.79 cm, mean weight 66.0±6.62 kg) participated in this study as voluntarily. Boxing athletes performed one trial in straight punch technique for each two different stance positions (orthodox and southpaw stances) at sandbag. The trials were recorded at a frequency of 120Hz using eight synchronized high-speed cameras (Oqus 7+), which were placed, approximately at right- angles to one another. The three-dimensional motion analysis was performed with a Motion Capture System (Qualisys, Sweden). Data was transferred to Windows-based data acquisition software, which was QTM (Qualisys Track Manager). 11 segment models were used for determination of the kinematic variables (Calf, leg, punch, upperarm, lowerarm, trunk). Also, the sandbag was markered for calculation of the impact forces. Wand calibration method (with T stick) was used for field calibration. The mean velocity and acceleration of the punch; mean acceleration of the sandbag and angles of the trunk, shoulder, hip and knee were calculated. Stance differences’ data were compared with Wilcoxon test for using SPSS 20.0 program. According to the results, there were statistically significant differences found in trunk angle on the sagittal plane (yz) (p<0.05). There was a significant difference also found in sandbag acceleration and impact forces between stance positions (p < 0.05). Boxing athletes achieved more impact forces and accelerations in orthodox stance position. It is recommended that to use an orthodox stance instead of southpaw stance in straight punch technique especially for creating more impact forces.

Keywords: boxing, impact force, kinematics, straight punch, orthodox, southpaw

Procedia PDF Downloads 290
43 A Technique for Planning the Application of Buttress Plate in the Medial Tibial Plateau Using the Preoperative CT Scan

Authors: P. Panwalkar, K. Veravalli, R. Gwynn, M. Tofighi, R. Clement, A. Mofidi

Abstract:

When operating on tibial plateau fracture especially medial tibial plateau, it has regularly been said “where do I put my thumb to reduce the fracture”. This refers to the ideal placement of the buttress device to hold the fracture till union. The aim of this study was to see if one can identify this sweet spot using a CT scan. Methods: Forty-five tibial plateau fractures with medial plateau involvement were identified and included in the study. The preoperative CT scans were analysed and the medial plateau involvement pattern was classified based on modified radiological classification by Yukata et-al of stress fracture of medial tibial plateau. The involvement of part of plateau was compared with position of buttress plate position which was classified as medial posteromedial or both. Presence and position of the buttress was compared with ability to achieve and hold the reduction of the fracture till union. Results: Thirteen fractures were type-1 fracture, 19 fractures were type-2 fracture and 13 fractures were type-3 fracture. Sixteen fractures were buttressed correctly according to the potential deformity and twenty-six fractures were not buttressed and three fractures were partly buttressed correctly. No fracture was over butressed! When the fracture was buttressed correctly the rate of the malunion was 0%. When fracture was partly buttressed 33% were anatomically united and 66% were united in the plane of buttress. When buttress was not used, 14 were malunited, one malunited in one of the two planes of deformity and eleven anatomically healed (of which 9 were non displaced!). Buttressing resulted in statistically significant lower mal-union rate (x2=7.8, p=0.0052). Conclusion: The classification based on involvement of medial condyle can identify the placement of buttress plate in the tibial plateau. The correct placement of the buttress plate results in predictably satisfactory union. There may be a correlation between injury shape of the tibial plateau and the fracture type.

Keywords: knee, tibial plateau, trauma, CT scan, surgery

Procedia PDF Downloads 120
42 Impact Force Difference on Natural Grass Versus Synthetic Turf Football Fields

Authors: Nathaniel C. Villanueva, Ian K. H. Chun, Alyssa S. Fujiwara, Emily R. Leibovitch, Brennan E. Yamamoto, Loren G. Yamamoto

Abstract:

Introduction: In previous studies of high school sports, over 15% of concussions were attributed to contact with the playing surface. While artificial turf fields are increasing in popularity due to lower maintenance costs, artificial turf has been associated with more ankle and knee injuries, with inconclusive data on concussions. In this study, natural grass and artificial football fields were compared in terms of deceleration on fall impact. Methods: Accelerometers were placed on the forehead, apex of the head, and right ear of a Century Body Opponent Bag (BOB) manikin. A Riddell HITS football helmet was secured onto the head of the manikin over the accelerometers. This manikin was dropped onto natural grass (n = 10) and artificial turf (n = 9) high school football fields. The manikin was dropped from a stationary position at a height of 60 cm onto its front, back, and left side. Each of these drops was conducted 10 times at the 40-yard line, 20-yard line, and endzone. The net deceleration on impact was calculated as a net vector from each of the three accelerometers’ x, y, and z vectors from the three different locations on the manikin’s head (9 vector measurements per drop). Results: Mean values for the multiple drops were calculated for each accelerometer and drop type for each field. All accelerometers in forward and backward falls and one accelerometer in side falls showed significantly greater impact force on synthetic turf compared to the natural grass surfaces. Conclusion: Impact force was higher on synthetic fields for all drop types for at least one of the accelerometer locations. These findings suggest that concussion risk might be higher for athletes playing on artificial turf fields.

Keywords: concussion, football, biomechanics, sports

Procedia PDF Downloads 119
41 Development and Validation of Work Movement Task Analysis: Part 1

Authors: Mohd Zubairy Bin Shamsudin

Abstract:

Work-related Musculoskeletal Disorder (WMSDs) is one of the occupational health problems encountered by workers over the world. In Malaysia, there is increasing in trend over the years, particularly in the manufacturing sectors. Current method to observe workplace WMSDs is self-report questionnaire, observation and direct measurement. Observational method is most frequently used by the researcher and practitioner because of the simplified, quick and versatile when it applies to the worksite. However, there are some limitations identified e.g. some approach does not cover a wide spectrum of biomechanics activity and not sufficiently sensitive to assess the actual risks. This paper elucidates the development of Work Movement Task Analysis (WMTA), which is an observational tool for industrial practitioners’ especially untrained personnel to assess WMSDs risk factors and provide a basis for suitable intervention. First stage of the development protocol involved literature reviews, practitioner survey, tool validation and reliability. A total of six themes/comments were received in face validity stage. New revision of WMTA consisted of four sections of postural (neck, back, shoulder, arms, and legs) and associated risk factors; movement, load, coupling and basic environmental factors (lighting, noise, odorless, heat and slippery floor). For inter-rater reliability study shows substantial agreement among rater with K = 0.70. Meanwhile, WMTA validation shows significant association between WMTA score and self-reported pain or discomfort for the back, shoulder&arms and knee&legs with p<0.05. This tool is expected to provide new workplace ergonomic observational tool to assess WMSDs for the next stage of the case study.

Keywords: assessment, biomechanics, musculoskeletal disorders, observational tools

Procedia PDF Downloads 446
40 A Modified Open Posterior Approach for the Fixation of Posterior Cruciate Ligament Tibial Avulsion Fractures

Authors: Babak Mirzashahi, Arvin Najafi, Pejman Mansouri, Mahmoud Farzan

Abstract:

Background: The most effective treatment of posterior cruciate ligament (PCL) tears and the consequence of untreated PCL injuries remain controversial. Objectives: The aim of this study is to assess outcomes of fixation of tibial posterior cruciate ligament (PCL) avulsion fractures via a modified technique. Patients and Methods: From January, 2009 to March, 2012, there were 45 cases of PCL tibial avulsion fractures that were referred to our hospital and were managed through a modified open posterior approach. Fixation of Tibial PCL avulsion fractures were fixed by means of a lag screw and washer placed through our modified open posterior approach. Range of motion was begun on the first postoperative day. Clinical stability, range of motion, gastrocnemius muscle strength, radiographic investigation, and patient’s overall quality of life was analyzed at final follow up visit. Results: The average of overall musculoskeletal functional evaluation scores was 15 (range 3–35). All patients achieved union of their fracture and had clinically stable knees at the latest follow-up. The mean preoperative Lysholm score for 15 knees was 62 ± 8 (range, 50-75); the mean postoperative Lysholm score was 92± 7 (range, 75-101). A significant difference in Lysholm scores between preoperative and final follow-up evaluations was found (P < .05). At first-year follow-up, 42 (93%) patients revealed a difference of less than 10 mm in thigh circumference between their injured and healthy knees. Conclusions: The management of displaced large PCL avulsion fractures with placement of a cancellous lag screw with washer by means of the modified open posterior approach leads to satisfactory clinical, radiographic, and functional results and reduces the operation time and less blood loss. Level of evidence: IV.

Keywords: posterior cruciate ligament, tibial fracture, lysholm knee score, patient outcome assessment

Procedia PDF Downloads 279
39 Ecological Ice Hockey Butterfly Motion Assessment Using Inertial Measurement Unit Capture System

Authors: Y. Zhang, J. Perez, S. Marnier

Abstract:

To date, no study on goaltending butterfly motion has been completed in real conditions, during an ice hockey game or training practice, to the author's best knowledge. This motion, performed to save score, is unnatural, intense, and repeated. The target of this research activity is to identify representative biomechanical criteria for this goaltender-specific movement pattern. Determining specific physical parameters may allow to will identify the risk of hip and groin injuries sustained by goaltenders. Four professional or academic goalies were instrumented during ice hockey training practices with five inertial measurement units. These devices were inserted in dedicated pockets located on each thigh and shank, and the fifth on the lumbar spine. A camera was also installed close to the ice to observe and record the goaltenders' activities, especially the butterfly motions, in order to synchronize the captured data and the behavior of the goaltender. Each data recorded began with a calibration of the inertial units and a calibration of the fully equipped goaltender on the ice. Three butterfly motions were recorded out of the training practice to define referential individual butterfly motions. Then, a data processing algorithm based on the Madgwick filter computed hip and knee joints joint range of motion as well as angular specific angular velocities. The developed algorithm software automatically identified and analyzed all the butterfly motions executed by the four different goaltenders. To date, it is still too early to show that the analyzed criteria are representative of the trauma generated by the butterfly motion as the research is only at its beginning. However, this descriptive research activity is promising in its ecological assessment, and once the criteria are found, the tools and protocols defined will allow the prevention of as many injuries as possible. It will thus be possible to build a specific training program for each goalie.

Keywords: biomechanics, butterfly motion, human motion analysis, ice hockey, inertial measurement unit

Procedia PDF Downloads 102
38 Design of an Active Compression System for Treating Vascular Disease Using a Series of Silicone Based Inflatable Mini Bladders

Authors: Gayani K. Nandasiri, Tilak Dias, William Hurley

Abstract:

Venous disease of human lower limb could range from minor asymptomatic incompetence of venous valves to chronic venous ulceration. The sheer prevalence of varicose veins and its associated significant costs of treating late complications such as chronic ulcers contribute to a higher burden on health care resources. In most of western countries with developed health care systems, treatment costs associated with Venous disease accounts for a considerable portion of their total health care budget, and it has become a high-cost burden to National Health Service (NHS), UK. The established gold standard of treatment for the venous disease is the graduated compression, where the pressure at the ankle being highest and decreasing towards the knee and thigh. Currently, medical practitioners use two main methods to treat venous disease; i.e. compression bandaging and compression stockings. Both these systems have their own disadvantages which lead to the current programme of research. The aim of the present study is to revolutionize the compression therapy by using a novel active compression system to deliver a controllable and more accurate pressure profiles using a series of inflatable mini bladders. Two types of commercially available silicones were tested for the application. The mini bladders were designed with a special fabrication procedure to provide required pressure profiles, and a series of experiments were conducted to characterise the mini bladders. The inflation/deflation heights of these mini bladders were investigated experimentally and using a finite element model (FEM), and the experimental data were compared to the results obtained from FEM simulations, which showed 70-80% agreement. Finally, the mini bladders were tested for its pressure transmittance characteristics, and the results showed a 70-80% of inlet air pressure transmitted onto the treated surface.

Keywords: finite element analysis, graduated compression, inflatable bladders, venous disease

Procedia PDF Downloads 160