Search results for: aortic wall elasticity
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1626

Search results for: aortic wall elasticity

1566 Elasticity Model for Easing Peak Hour Demand for Metrorail Transport System

Authors: P. K. Sarkar, Amit Kumar Jain

Abstract:

The demand for Urban transportation is characterised by a large scale temporal and spatial variations which causes heavy congestion inside metro trains in peak hours near Centre Business District (CBD) of the city. The conventional approach to address peak hour congestion, metro trains has been to increase the supply by way of introduction of more trains, increasing the length of the trains, optimising the time table to increase the capacity of the system. However, there is a limitation of supply side measures determined by the design capacity of the systems beyond which any addition in the capacity requires huge capital investments. The demand side interventions are essentially required to actually spread the demand across the time and space. In this study, an attempt has been made to identify the potential Transport Demand Management tools applicable to Urban Rail Transportation systems with a special focus on differential pricing. A conceptual price elasticity model has been developed to analyse the effect of various combinations of peak and nonpeak hoursfares on demands. The elasticity values for peak hour, nonpeak hour and cross elasticity have been assumed from the relevant literature available in the field. The conceptual price elasticity model so developed is based on assumptions which need to be validated with actual values of elasticities for different segments of passengers. Once validated, the model can be used to determine the peak and nonpeak hour fares with an objective to increase overall ridership, revenue, demand levelling and optimal utilisation of assets.

Keywords: urban transport, differential fares, congestion, transport demand management, elasticity

Procedia PDF Downloads 282
1565 FEM Investigation of Inhomogeneous Wall Thickness Backward Extrusion for Aerosol Can Manufacturing

Authors: Jemal Ebrahim Dessie, Zsolt Lukacs

Abstract:

The wall of the aerosol can is extruded from the backward extrusion process. Necking is another forming process stage developed on the can shoulder after the backward extrusion process. Due to the thinner thickness of the wall, buckling is the critical challenge for current pure aluminum aerosol can industries. Design and investigation of extrusion with inhomogeneous wall thickness could be the best solution for reducing and optimization of neck retraction numbers. FEM simulation of inhomogeneous wall thickness has been simulated through this investigation. From axisymmetric Deform-2D backward extrusion, an aerosol can with a thickness of 0.4 mm at the top and 0.33 mm at the bottom of the aerosol can have been developed. As the result, it can optimize the number of retractions of the necking process and manufacture defect-free aerosol can shoulder due to the necking process.

Keywords: aerosol can, backward extrusion, Deform-2D, necking

Procedia PDF Downloads 149
1564 Challenges of Management of Subaortic Membrane in a Young Adult Patient: A Case Review and Literature Review

Authors: Talal Asif, Maya Kosinska, Lucas Georger, Krish Sardesai, Muhammad Shah Miran

Abstract:

This article presents a case review and literature review focused on the challenges of managing subaortic membranes (SAM) in young adult patients with mild aortic regurgitation (AR) or aortic stenosis (AS). The study aims to discuss the diagnosis of SAM, imaging studies used for assessment, management strategies in young patients, the risk of valvular damage, and the controversy surrounding prophylactic resection in mild AR. The management of SAM in adults poses challenges due to limited treatment options and potential complications, necessitating further investigation into the progression of AS and AR in asymptomatic SAM patients. The case presentation describes a 40-year-old male with muscular dystrophy who presented with symptoms and was diagnosed with SAM. Various imaging techniques, including CT chest, transthoracic echocardiogram (TTE), and transesophageal echocardiogram (TEE), were used to confirm the presence and severity of SAM. Based on the patient's clinical profile and the absence of surgical indications, medical therapy was initiated, and regular outpatient follow-up was recommended to monitor disease progression. The discussion highlights the challenges in diagnosing SAM, the importance of imaging studies, and the potential complications associated with SAM in young patients. The article also explores the management options for SAM, emphasizing surgical resection as the definitive treatment while acknowledging the limited success rates of alternative approaches. Close monitoring and prompt intervention for complications are crucial in the management of SAM. The concluding statement emphasizes the need for further research to explore alternative treatments for SAM in young patients.

Keywords: subaortic membrane, management, case report, literature review, aortic regurgitation, aortic stenosis, left ventricular outflow obstruction, guidelines, heart failure

Procedia PDF Downloads 63
1563 Experimental Modal Analysis of a Suspended Composite Beam

Authors: First A. Lahmar Lahbib, Second B. Abdeldjebar Rabiâ, Third C. Moudden B, forth D. Missoum L

Abstract:

Vibration tests are used to identify the elasticity modulus in two directions. This strategy is applied to composite materials glass / polyester. Experimental results made on a specimen in free vibration showed the efficiency of this method. Obtained results were validated by a comparison to results stemming from static tests.

Keywords: beam, characterization, composite, elasticity modulus, vibration.

Procedia PDF Downloads 438
1562 Economic Stability in a Small Open Economy with Income Effect on Leisure Demand

Authors: Yu-Shan Hsu

Abstract:

This paper studies a two-sector growth model with a technology of social constant returns and with a utility that features either a zero or a positive income effect on the demand for leisure. The purpose is to investigate how the existence of aggregate instability or equilibrium indeterminacy depends on both the intensity of the income effect on the demand for leisure and the value of the labor supply elasticity. The main finding is that when there is a factor intensity reversal between the private perspective and the social perspective, indeterminacy arises even if the utility has a positive income effect on leisure demand. Moreover, we find that a smaller value of the labor supply elasticity increases the range of the income effect on leisure demand and thus increases the possibility of equilibrium indeterminacy. JEL classification: E3; O41

Keywords: indeterminacy, non-separable preferences, income effect, labor supply elasticity

Procedia PDF Downloads 142
1561 Wall Heat Flux Mapping in Liquid Rocket Combustion Chamber with Different Jet Impingement Angles

Authors: O. S. Pradeep, S. Vigneshwaran, K. Praveen Kumar, K. Jeyendran, V. R. Sanal Kumar

Abstract:

The influence of injector attitude on wall heat flux plays an important role in predicting the start-up transient and also determining the combustion chamber wall durability of liquid rockets. In this paper comprehensive numerical studies have been carried out on an idealized liquid rocket combustion chamber to examine the transient wall heat flux during its start-up transient at different injector attitude. Numerical simulations have been carried out with the help of a validated 2d axisymmetric, double precision, pressure-based, transient, species transport, SST k-omega model with laminar finite rate model for governing turbulent-chemistry interaction for four cases with different jet intersection angles, viz., 0o, 30o, 45o, and 60o. We concluded that the jets intersection angle is having a bearing on the time and location of the maximum wall-heat flux zone of the liquid rocket combustion chamber during the start-up transient. We also concluded that the wall heat flux mapping in liquid rocket combustion chamber during the start-up transient is a meaningful objective for the chamber wall material selection and the lucrative design optimization of the combustion chamber for improving the payload capability of the rocket.  

Keywords: combustion chamber, injector, liquid rocket, rocket engine wall heat flux

Procedia PDF Downloads 457
1560 Wind Fragility for Soundproof Wall with the Variation of Section Shape of Frame

Authors: Seong Do Kim, Woo Young Jung

Abstract:

Recently, damages due to typhoons and strong wind are on the rise. Considering this issue, we evaluated the performance of soundproofing walls based on the strong wind fragility by means of numerical analysis. Among the components of the soundproof wall, aluminum frame was the most vulnerable member, thus we have considered different section of aluminum frame in the determination of wind fragility. Wind load was randomly generated using Monte Carlo Simulation method. Moreover, limit state was based on the test standard of road construction soundproofing wall. In this study, the strong wind fragility was determined by considering the influence factors of wind exposure category, soundproof wall’s installation position, and shape of aluminum frame section. Results of this study could be used to determine the section shape of the frame that has high resistance to the wind during construction of the soundproofing wall.

Keywords: aluminum frame soundproofing wall, Monte Carlo simulation, numerical simulation, wind fragility

Procedia PDF Downloads 229
1559 Electrical and Thermal Characteristics of a Photovoltaic Solar Wall with Passive and Active Ventilation through a Room

Authors: Himanshu Dehra

Abstract:

An experimental study was conducted for ascertaining electrical and thermal characteristics of a pair of photovoltaic (PV) modules integrated with solar wall of an outdoor room. A pre-fabricated outdoor room was setup for conducting outdoor experiments on a PV solar wall with passive and active ventilation through the outdoor room. The selective operating conditions for glass coated PV modules were utilized for establishing their electrical and thermal characteristics. The PV solar wall was made up of glass coated PV modules, a ventilated air column, and an insulating layer of polystyrene filled plywood board. The measurements collected were currents, voltages, electric power, air velocities, temperatures, solar intensities, and thermal time constant. The results have demonstrated that: i) a PV solar wall installed on a wooden frame was of more heat generating capacity in comparison to a window glass or a standalone PV module; ii) generation of electric power was affected with operation of vertical PV solar wall; iii) electrical and thermal characteristics were not significantly affected by heat and thermal storage losses; and iv) combined heat and electricity generation were function of volume of thermal and electrical resistances developed across PV solar wall. Finally, a comparison of temperature plots of passive and active ventilation envisaged that fan pressure was necessary to avoid overheating of the PV solar wall. The active ventilation was necessary to avoid over-heating of the PV solar wall and to maintain adequate ventilation of room under mild climate conditions.

Keywords: photovoltaic solar wall, solar energy, passive ventilation, active ventilation

Procedia PDF Downloads 371
1558 Probabilistic and Stochastic Analysis of a Retaining Wall for C-Φ Soil Backfill

Authors: André Luís Brasil Cavalcante, Juan Felix Rodriguez Rebolledo, Lucas Parreira de Faria Borges

Abstract:

A methodology for the probabilistic analysis of active earth pressure on retaining wall for c-Φ soil backfill is described in this paper. The Rosenblueth point estimate method is used to measure the failure probability of a gravity retaining wall. The basic principle of this methodology is to use two point estimates, i.e., the standard deviation and the mean value, to examine a variable in the safety analysis. The simplicity of this framework assures to its wide application. For the calculation is required 2ⁿ repetitions during the analysis, since the system is governed by n variables. In this study, a probabilistic model based on the Rosenblueth approach for the computation of the overturning probability of failure of a retaining wall is presented. The obtained results have shown the advantages of this kind of models in comparison with the deterministic solution. In a relatively easy way, the uncertainty on the wall and fill parameters are taken into account, and some practical results can be obtained for the retaining structure design.

Keywords: retaining wall, active earth pressure, backfill, probabilistic analysis

Procedia PDF Downloads 381
1557 Using Atomic Force Microscope to Investigate the Influence of UVA Radiation and HA on Cell Behaviour and Elasticity of Dermal Fibroblasts

Authors: Pei-Hsiu Chiang, Ling Hong Huang, Hsin-I Chang

Abstract:

In this research, we used UVA irradiation, which can penetrate into dermis and fibroblasts, the most abundant cells in dermis, to investigate the effect of UV light on dermis, such as inflammation, ECM degradation and elasticity loss. Moreover, this research is focused on the influence of hyaluronic acid (HA) on UVA treated dermal fibroblasts. We aim to establish whether HA can effectively relief ECM degradation, and restore the elasticity of UVA-damaged fibroblasts. Prolonged exposure to UVA radiation can damage fibroblasts and led variation in cell morphology and reduction in cell viability. Besides, UVA radiation can induce IL-1β expression on fibroblasts and then promote MMP-1 and MMP-3 expression, which can accelerate ECM degradation. On the other hand, prolonged exposure to UVA radiation reduced collagen and elastin synthesis on fibroblasts. Due to the acceleration of ECM degradation and the reduction of ECM synthesis, Atomic force microscope (AFM) was used to analyze the elasticity reduction on UVA-damaged fibroblasts. UVA irradiation causes photoaging on fibroblasts. UVA damaged fibroblasts with HA treatment can down-regulate the gene expression of MMP-1, MMP-3, and then slow down ECM degradation. On the other hand, HA may restore elastin and collagen synthesis in UV-damaged fibroblasts. Based on the slowdown of ECM degradation, UVA-damaged fibroblast elasticity can be effectively restored by HA treatment. In summary, HA can relief the photoaging conditions on fibroblasts, but may not be able to return fibroblasts to normal, healthy state. Although HA cannot fully recover UVA-damaged fibroblasts, HA is still potential for repairing photoaging skin.

Keywords: atomic force microscope, hyaluronic acid, UVA radiation, dermal fibroblasts

Procedia PDF Downloads 361
1556 Improvements in Double Q-Learning for Anomalous Radiation Source Searching

Authors: Bo-Bin Xiaoa, Chia-Yi Liua

Abstract:

In the task of searching for anomalous radiation sources, personnel holding radiation detectors to search for radiation sources may be exposed to unnecessary radiation risk, and automated search using machines becomes a required project. The research uses various sophisticated algorithms, which are double Q learning, dueling network, and NoisyNet, of deep reinforcement learning to search for radiation sources. The simulation environment, which is a 10*10 grid and one shielding wall setting in it, improves the development of the AI model by training 1 million episodes. In each episode of training, the radiation source position, the radiation source intensity, agent position, shielding wall position, and shielding wall length are all set randomly. The three algorithms are applied to run AI model training in four environments where the training shielding wall is a full-shielding wall, a lead wall, a concrete wall, and a lead wall or a concrete wall appearing randomly. The 12 best performance AI models are selected by observing the reward value during the training period and are evaluated by comparing these AI models with the gradient search algorithm. The results show that the performance of the AI model, no matter which one algorithm, is far better than the gradient search algorithm. In addition, the simulation environment becomes more complex, the AI model which applied Double DQN combined Dueling and NosiyNet algorithm performs better.

Keywords: double Q learning, dueling network, NoisyNet, source searching

Procedia PDF Downloads 79
1555 Endovascular Aneurysm Repair (Evar) with Endoanchors: For Tandem Aortic Abdominal Aneurysm (Aaa) with Hostile Neck & Proximal Penetrating Atherosclerotic Ulcer

Authors: Von Jerick Tenorio, Jonald Lucero, Marivic Vestal, Edwin Tiempo

Abstract:

In patients with hostile aortic neck anatomy, the risks of proximal seal complications and stent migration remain with EVAR despite improved endograft technology. This case report discusses how the technical challenges of the hostile neck anatomy, proximal penetrating atherosclerotic ulcer (PAU) and tortuous femoral access were addressed. The CT aortogram of a 63-year-old hypertensive and diabetic man with recurring abdominal discomfort revealed a fusiform infra-renal aneurysm measuring 8.8 cm in length and 5.7 cm in diameter. The proximal landing zone only has a 3 mm healthy neck with a conicity of > 10% and a thrombus of 4 mm thick. Proximal to the aneurysm is a PAU with a circumferential mural thrombus. The right femoral artery is tortuous with > 90o angulation. A 20% oversized Endurant II endograft and Aptus Heli-FX EndoAnchors were deployed as prophylaxis for type I endoleaks and endograft migration consequent to the conical neck and proximal aneurysm extension consequent to the PAU. A stiff Backup Meier guide wire facilitated the deployment of the endograft. Coil embolization of the right internal iliac artery was performed as prophylaxis for type II endoleaks. EndoAnchors can be used as an adjunct to EVAR as prophylaxis for proximal seal complications and stent migration in patients with hostile aortic aneurysm neck anatomy and concomitant proximal PAU.

Keywords: endoAnchors, endoleaks, EVAR, hostile neck

Procedia PDF Downloads 170
1554 Numerical Modeling of a Retaining Wall in Soil Reinforced by Layers of Geogrids

Authors: M. Mellas, S. Baaziz, A. Mabrouki, D. Benmeddour

Abstract:

The reinforcement of massifs of backfill with horizontal layers of geosynthetics is an interesting economic solution, which ensures the stability of retaining walls. The mechanical behavior of reinforced soil by geosynthetic is complex, and requires studies and research to understand the mechanisms of rupture. The behavior of reinforcements in the soil and the behavior of the main elements of the system: reinforcement-wall-soil. The present study is interested in numerical modeling of a retaining wall in soil reinforced by horizontal layers of geogrids. This modeling makes use of the software FLAC3D. This work aims to analyze the effect of the length of the geogrid "L" where the soil massif is supporting a uniformly distributed surcharge "Q", taking into account the fixing elements rather than the layers of geogrids to the wall.

Keywords: retaining wall, geogrid, reinforced soil, numerical modeling, FLAC3D

Procedia PDF Downloads 455
1553 Experimental Performance and Numerical Simulation of Double Glass Wall

Authors: Thana Ananacha

Abstract:

This paper reports the numerical and experimental performances of Double Glass Wall are investigated. Two configurations were considered namely, the Double Clear Glass Wall (DCGW) and the Double Translucent Glass Wall (DTGW). The coupled governing equations as well as boundary conditions are solved using the finite element method (FEM) via COMSOLTM Multiphysics. Temperature profiles and flow field of the DCGW and DTGW are reported and discussed. Different constant heat fluxes were considered namely 400 and 800 W.m-2 the corresponding initial condition temperatures were to 30.5 and 38.5 ºC respectively. The results show that the simulation results are in agreement with the experimental data. Conclusively, the model considered in this study could reasonable be used simulate the thermal and ventilation performance of the DCGW and DTGW configurations.

Keywords: thermal simulation, Double Glass Wall, velocity field, finite element method (FEM)

Procedia PDF Downloads 332
1552 A Case of Prosthetic Vascular-Graft Infection Due to Mycobacterium fortuitum

Authors: Takaaki Nemoto

Abstract:

Case presentation: A 69-year-old Japanese man presented with a low-grade fever and fatigue that had persisted for one month. The patient had an aortic dissection on the aortic arch 13 years prior, an abdominal aortic aneurysm seven years prior, and an aortic dissection on the distal aortic arch one year prior, which were all treated with artificial blood-vessel replacement surgery. Laboratory tests revealed an inflammatory response (CRP 7.61 mg/dl), high serum creatinine (Cr 1.4 mg/dL), and elevated transaminase (AST 47 IU/L, ALT 45 IU/L). The patient was admitted to our hospital on suspicion of prosthetic vascular graft infection. Following further workups on the inflammatory response, an enhanced chest computed tomography (CT) and a non-enhanced chest DWI (MRI) were performed. The patient was diagnosed with a pulmonary fistula and a prosthetic vascular graft infection on the distal aortic arch. After admission, the patient was administered Ceftriaxion and Vancomycine for 10 days, but his fever and inflammatory response did not improve. On day 13 of hospitalization, a lung fistula repair surgery and an omental filling operation were performed, and Meropenem and Vancomycine were administered. The fever and inflammatory response continued, and therefore we took repeated blood cultures. M. fortuitum was detected in a blood culture on day 16 of hospitalization. As a result, we changed the treatment regimen to Amikacin (400 mg/day), Meropenem (2 g/day), and Cefmetazole (4 g/day), and the fever and inflammatory response began to decrease gradually. We performed a test of sensitivity for Mycobacterium fortuitum, and found that the MIC was low for fluoroquinolone antibacterial agent. The clinical course was good, and the patient was discharged after a total of 8 weeks of intravenous drug administration. At discharge, we changed the treatment regimen to Levofloxacin (500 mg/day) and Clarithromycin (800 mg/day), and prescribed these two drugs as a long life suppressive therapy. Discussion: There are few cases of prosthetic vascular graft infection caused by mycobacteria, and a standard therapy remains to be established. For prosthetic vascular graft infections, it is ideal to provide surgical and medical treatment in parallel, but in this case, surgical treatment was difficult and, therefore, a conservative treatment was chosen. We attempted to increase the treatment success rate of this refractory disease by conducting a susceptibility test for mycobacteria and treating with different combinations of antimicrobial agents, which was ultimately effective. With our treatment approach, a good clinical course was obtained and continues at the present stage. Conclusion: Although prosthetic vascular graft infection resulting from mycobacteria is a refractory infectious disease, it may be curative to administer appropriate antibiotics based on the susceptibility test in addition to surgical treatment.

Keywords: prosthetic vascular graft infection, lung fistula, Mycobacterium fortuitum, conservative treatment

Procedia PDF Downloads 126
1551 Numerical Investigation of the Effect of Number of Waves on Heat Transfer in a Wavy Wall Enclosure

Authors: Ali Reza Tahavvor, Saeed Hosseini, Afshin Karimzadeh Fard

Abstract:

In this paper the effect of wall waviness of side walls in a two-dimensional wavy enclosure is numerically investigated. Two vertical wavy walls and straight top wall are kept isothermal and the bottom wall temperature is higher and spatially varying with cosinusoidal temperature distribution. A computational code based on Finite-volume approach is used to solve governing equations and SIMPLE method is used for pressure velocity coupling. Test is performed for several different numbers of undulations. The Prandtl number was kept constant and the Ra number denotes that the flow is laminar. Temperature and velocity fields are determined. Therefore, according to the obtained results a correlation is proposed for average Nusselt number as a function of number of side wall waves. The results indicate that the Nusselt number is highly affected by number of waves and increasing it decreases the wavy walls Nusselt number; although the Nusselt number is not highly affected by surface waviness when the number of undulations is below one.

Keywords: cavity, natural convection, Nusselt number, wavy wall

Procedia PDF Downloads 428
1550 The Control of Wall Thickness Tolerance during Pipe Purchase Stage Based on Reliability Approach

Authors: Weichao Yu, Kai Wen, Weihe Huang, Yang Yang, Jing Gong

Abstract:

Metal-loss corrosion is a major threat to the safety and integrity of gas pipelines as it may result in the burst failures which can cause severe consequences that may include enormous economic losses as well as the personnel casualties. Therefore, it is important to ensure the corroding pipeline integrity and efficiency, considering the value of wall thickness, which plays an important role in the failure probability of corroding pipeline. Actually, the wall thickness is controlled during pipe purchase stage. For example, the API_SPEC_5L standard regulates the allowable tolerance of the wall thickness from the specified value during the pipe purchase. The allowable wall thickness tolerance will be used to determine the wall thickness distribution characteristic such as the mean value, standard deviation and distribution. Taking the uncertainties of the input variables in the burst limit-state function into account, the reliability approach rather than the deterministic approach will be used to evaluate the failure probability. Moreover, the cost of pipe purchase will be influenced by the allowable wall thickness tolerance. More strict control of the wall thickness usually corresponds to a higher pipe purchase cost. Therefore changing the wall thickness tolerance will vary both the probability of a burst failure and the cost of the pipe. This paper describes an approach to optimize the wall thickness tolerance considering both the safety and economy of corroding pipelines. In this paper, the corrosion burst limit-state function in Annex O of CSAZ662-7 is employed to evaluate the failure probability using the Monte Carlo simulation technique. By changing the allowable wall thickness tolerance, the parameters of the wall thickness distribution in the limit-state function will be changed. Using the reliability approach, the corresponding variations in the burst failure probability will be shown. On the other hand, changing the wall thickness tolerance will lead to a change in cost in pipe purchase. Using the variation of the failure probability and pipe cost caused by changing wall thickness tolerance specification, the optimal allowable tolerance can be obtained, and used to define pipe purchase specifications.

Keywords: allowable tolerance, corroding pipeline segment, operation cost, production cost, reliability approach

Procedia PDF Downloads 362
1549 Investigation of Dynamic Heat Transfer in Masonry Walls

Authors: Joelle Al Fakhoury, Emilio Sassine, Yassine Cherif, Joseph Dgheim, Emmanuel Antczak

Abstract:

Hollow block masonry is the most used building technology in the Lebanese context. These blocks are manufactured in an artisanal way and have unknown thermal properties; their overall thermos-physical performance is thus unknown and also poorly investigated scientifically in both single wall and also double wall configurations. In this work, experimental measurements and numerical simulations are performed for a better understanding of the heat transfer in masonry walls. This study was realized using an experimental setup consisting of a masonry hollow block wall (0.1m x 1m x 1m) and two heat boxes, such that each covers one side of the wall. The first is a reference box having a constant interior temperature, and the other is a control box having an adjustable interior temperature. At first, the numerical model is validated using an experimental setup; then 3D numerical analyzes are held in order to investigate the effect of the air gap, the mortar joints, and the plastering on the thermal performance of masonry walls for a better understanding of the heat transfer process and the recommendation of suitable thermal improvements.

Keywords: masonry wall, hollow blocks, heat transfer, wall instrumentation, thermal improvement

Procedia PDF Downloads 198
1548 Measurement of the Dynamic Modulus of Elasticity of Cylindrical Concrete Specimens Used for the Cyclic Indirect Tensile Test

Authors: Paul G. Bolz, Paul G. Lindner, Frohmut Wellner, Christian Schulze, Joern Huebelt

Abstract:

Concrete, as a result of its use as a construction material, is not only subject to static loads but is also exposed to variables, time-variant, and oscillating stresses. In order to ensure the suitability of construction materials for resisting these cyclic stresses, different test methods are used for the systematic fatiguing of specimens, like the cyclic indirect tensile test. A procedure is presented that allows the estimation of the degradation of cylindrical concrete specimens during the cyclic indirect tensile test by measuring the dynamic modulus of elasticity in different states of the specimens’ fatigue process. Two methods are used in addition to the cyclic indirect tensile test in order to examine the dynamic modulus of elasticity of cylindrical concrete specimens. One of the methods is based on the analysis of eigenfrequencies, whilst the other one uses ultrasonic pulse measurements to estimate the material properties. A comparison between the dynamic moduli obtained using the three methods that operate in different frequency ranges shows good agreement. The concrete specimens’ fatigue process can therefore be monitored effectively and reliably.

Keywords: concrete, cyclic indirect tensile test, degradation, dynamic modulus of elasticity, eigenfrequency, fatigue, natural frequency, ultrasonic, ultrasound, Young’s modulus

Procedia PDF Downloads 141
1547 Experimental Investigation of the Failure Behavior of a Retaining Wall Constructed with Soil Bags

Authors: Kewei Fan, Sihong Liu, Yi Pik Cheng

Abstract:

This paper aims to analyse the failure behaviour of the retaining wall constructed with soil bags that are formed by filling river sand into woven bags (geosynthetics). Model tests were conducted to obtain the failure mode of the wall, and shear tests on two-layers and five-layers of soil bags were designed to investigate the mechanical characteristics of the interface of soil bags. The test results show that the slip surface in the soil bags-constructed retaining wall is ladder-like due to the inter-layer insertion of soil bags, and the wall above the ladder-like surface undergoes a rigid body translation. The insertion strengthens the shear strength of two-layer staggered-stacked soil bags. Meanwhile, it affects the shape of the slip surface of the five-layer staggered-stacked soil bags. Finally, the interlayer resisting friction of soil bags is found to be related to the shape of the slip surface.

Keywords: geosynthetics, retaining wall, soil bag, failure mode, interface, shear strength

Procedia PDF Downloads 98
1546 Gaussian Mixture Model Based Identification of Arterial Wall Movement for Computation of Distension Waveform

Authors: Ravindra B. Patil, P. Krishnamoorthy, Shriram Sethuraman

Abstract:

This work proposes a novel Gaussian Mixture Model (GMM) based approach for accurate tracking of the arterial wall and subsequent computation of the distension waveform using Radio Frequency (RF) ultrasound signal. The approach was evaluated on ultrasound RF data acquired using a prototype ultrasound system from an artery mimicking flow phantom. The effectiveness of the proposed algorithm is demonstrated by comparing with existing wall tracking algorithms. The experimental results show that the proposed method provides 20% reduction in the error margin compared to the existing approaches in tracking the arterial wall movement. This approach coupled with ultrasound system can be used to estimate the arterial compliance parameters required for screening of cardiovascular related disorders.

Keywords: distension waveform, Gaussian Mixture Model, RF ultrasound, arterial wall movement

Procedia PDF Downloads 475
1545 The Effects of Displacer-Cylinder-Wall Conditions on the Performance of a Medium-Temperature-Differential γ-Type Stirling Engine

Authors: Wen-Lih Chen, Chao-Kuang Chen, Mao-Ju Fang, Hsiang-Cheng Hsu

Abstract:

In this study, we conducted CFD simulation to study the gas cycle of a medium-temperature-differential (MTD) γ-type Stirling engine. Mesh compression and expansion as well as overset mesh techniques are employed to simulate the moving parts of the engine. Shear-Stress Transport (SST) k-ω turbulence model has been adopted because the model is not prone to generate excessive turbulence upon impingement regions. Hence, wall heat transfer rates at the hot and cold ends will not be overestimated. The effects of several different displacer-cylinder-wall temperature setups, including smooth and finned walls, on engine performance are investigated. The results include temperature contours, pressure versus volume diagrams, and variations of heat transfer rates, indicated power, and efficiency. It is found that displacer-wall heat transfer is one of the most important factors on engine performance, and some wall-temperature setups produce better results than others.

Keywords: CFD, finned wall, MTD Stirling engine, heat transfer

Procedia PDF Downloads 330
1544 Analysis of Contact Width and Contact Stress of Three-Layer Corrugated Metal Gasket

Authors: I. Made Gatot Karohika, Shigeyuki Haruyama, Ken Kaminishi, Oke Oktavianty, Didik Nurhadiyanto

Abstract:

Contact width and contact stress are important parameters related to the leakage behavior of corrugated metal gasket. In this study, contact width and contact stress of three-layer corrugated metal gasket are investigated due to the modulus of elasticity and thickness of surface layer for 2 type gasket (0-MPa and 400-MPa mode). A finite element method was employed to develop simulation solution to analysis the effect of each parameter. The result indicated that lowering the modulus of elasticity ratio of surface layer will result in better contact width but the average contact stresses are smaller. When the modulus of elasticity ratio is held constant with thickness ratio increase, its contact width has an increscent trend otherwise the average contact stress has decreased trend.

Keywords: contact width, contact stress, layer, metal gasket, corrugated, simulation

Procedia PDF Downloads 288
1543 Analysis of Sound Loss from the Highway Traffic through Lightweight Insulating Concrete Walls and Artificial Neural Network Modeling of Sound Transmission

Authors: Mustafa Tosun, Kevser Dincer

Abstract:

In this study, analysis on whether the lightweight concrete walled structures used in four climatic regions of Turkey are also capable of insulating sound was conducted. As a new approach, first the wall’s thermal insulation sufficiency’s were calculated and then, artificial neural network (ANN) modeling was used on their cross sections to check if they are sound transmitters too. The ANN was trained and tested by using MATLAB toolbox on a personal computer. ANN input parameters that used were thickness of lightweight concrete wall, frequency and density of lightweight concrete wall, while the transmitted sound was the output parameter. When the results of the TS analysis and those of ANN modeling are evaluated together, it is found from this study, that sound transmit loss increases at higher frequencies, higher wall densities and with larger wall cross sections.

Keywords: artificial neuron network, lightweight concrete, sound insulation, sound transmit loss

Procedia PDF Downloads 224
1542 Calculation of the Added Mass of a Submerged Object with Variable Sizes at Different Distances from the Wall via Lattice Boltzmann Simulations

Authors: Nastaran Ahmadpour Samani, Shahram Talebi

Abstract:

Added mass is an important quantity in analysis of the motion of a submerged object ,which can be calculated by solving the equation of potential flow around the object . Here, we consider systems in which a square object is submerged in a channel of fluid and moves parallel to the wall. The corresponding added mass at a given distance from the wall d and for the object size s (which is the side of square object) is calculated via lattice Blotzmann simulation . By changing d and s separately, their effect on the added mass is studied systematically. The simulation results reveal that for the systems in which d > 4s, the distance does not influence the added mass any more. The added mass increases when the object approaches the wall and reaches its maximum value as it moves on the wall (d -- > 0). In this case, the added mass is about 73% larger than which of the case d=4s. In addition, it is observed that the added mass increases by increasing of the object size s and vice versa.

Keywords: Lattice Boltzmann simulation , added mass, square, variable size

Procedia PDF Downloads 436
1541 Surveying Coastal Society Perception on Giant Sea Wall Jakarta Development Planning

Authors: Ammar Asfari, Faizah Finur Fithriah, Shighia Ajeng Savitri

Abstract:

Jakarta as the capital city of Indonesia held an important role for the country, that is being the city where central government is located. But its topographic character which categorized as lowland area is causing an ultimate trouble. With average height of 7 meters above the sea level, flood keeps occurring in this city. On the other hand, water exploitation that caused land subsidence and sea-levels increasing by global warming make it even worse. Giant Sea Wall Development is a project created by Jakarta’s government to overcome flood, which is inspired by Saemangeum Dam in South Korea. For further planning, Giant Sea Wall is planned to be water reservoir for Jakarta’s inhabitants. This research’s aim is to fully understand the knowledge and opinion of people living in North Jakarta (Jakarta’s Coastal Area) on Giant Sea Wall development planning using qualitative method analysis with descriptive approach. The result of this research will be one of the determining factors in Giant Sea Wall Jakarta development planning continuance.

Keywords: descriptive approach, Giant Sea Wall Jakarta, qualitative method analysis, society perception

Procedia PDF Downloads 254
1540 Hygrothermal Assessment of Internally Insulated Prefabricated Concrete Wall in Polish Climatic Condition

Authors: D. Kaczorek

Abstract:

Internal insulation of external walls is often problematic due to increased moisture content in the wall and interstitial or surface condensation risk. In this paper, the hygrothermal performance of prefabricated, concrete, large panel, external wall typical for WK70 system, commonly used in Poland in the 70’s, with inside, additional insulation was investigated. Thermal insulation board made out of hygroscopic, natural materials with moisture buffer capacity and extruded polystyrene (EPS) board was used as interior insulation. Experience with this natural insulation is rare in Poland. The analysis was performed using WUFI software. First of all, the impact of various standard boundary conditions on the behavior of the different wall assemblies was tested. The comparison of results showed that the moisture class according to the EN ISO 13788 leads to too high values of total moisture content in the wall since the boundary condition according to the EN 15026 should be usually applied. Then, hygrothermal 1D-simulations were conducted by WUFI Pro for analysis of internally added insulation, and the weak point like the joint of the wall with the concrete ceiling was verified using 2D simulations. Results showed that, in the Warsaw climate and the indoor conditions adopted in accordance with EN 15026, in the tested wall assemblies, regardless of the type of interior insulation, there would not be any problems with moisture - inside the structure and on the interior surface.

Keywords: concrete large panel wall, hygrothermal simulation, internal insulation, moisture related issues

Procedia PDF Downloads 138
1539 The Implementation of Word Study Wall in an Online English Word Memorization Class

Authors: Yidan Shao

Abstract:

With the advancement of the economy, technology promotes online teaching, and learning has become one of the common features in the educational field. Meanwhile, the dramatic expansion of the online environment provides opportunities for more learners, including second language learners. A greater command of vocabulary improves students’ learning capacity, and word acquisition and development play a critical role in learning. Furthermore, the Word Wall is an effective tool to improve students’ knowledge of words, which works for a wide range of age groups. Therefore, this study is going to use the Word Wall as an intervention to examine whether it can bring some memorization changes in an online English language class for a second language learner based on the word morphology method. The participant will take ten courses in the experiment as it plans. The findings show that the Word Wall activity plays a slight role in improving word memorizing, but it does affect instant memorization. If longer periods and more comprehensive designs of research can be applied, it is expected to have more value.

Keywords: second language acquisition, word morphology, word memorization, the Word Wall

Procedia PDF Downloads 83
1538 The Influence of Design Complexity of a Building Structure on the Expected Performance

Authors: Ormal Lishi

Abstract:

This research presents a computationally efficient probabilistic method to assess the performance of compartmentation walls with similar Fire Resistance Levels (FRL) but varying complexity. Specifically, a masonry brick wall and a light-steel framed (LSF) wall with comparable insulation performance are analyzed. A Monte Carlo technique, employing Latin Hypercube Sampling (LHS), is utilized to quantify uncertainties and determine the probability of failure for both walls exposed to standard and parametric fires, following ISO 834 and Eurocodes guidelines. Results show that the probability of failure for the brick masonry wall under standard fire exposure is estimated at 4.8%, while the LSF wall is 7.6%. These probabilities decrease to 0.4% and 4.8%, respectively, when subjected to parametric fires. Notably, the complex LSF wall exhibits higher variability in predicting time to failure for specific criteria compared to the less complex brick wall, especially at higher temperatures. The proposed approach highlights the need for Probabilistic Risk Assessment (PRA) to accurately evaluate the reliability and safety levels of complex designs.

Keywords: design complexity, probability of failure, monte carlo analysis, compartmentation walls, insulation

Procedia PDF Downloads 33
1537 Numerical Simulation of the Coal Spontaneous Combustion Dangerous Area in Composite Long-Wall Gobs

Authors: Changshan Zhang, Zhijin Yu, Shixing Fan

Abstract:

A comprehensive hazard evaluation for coal self-heating in composite long-wall gobs is heavily dependent on computational simulation. In this study, the spatial distributions of cracks which caused significant air leakage were simulated by universal distinct element code (UDEC) simulation. Based on the main routes of air leakage and characteristics of coal self-heating, a computational fluid dynamics (CFD) modeling was conducted to model the coal spontaneous combustion dangerous area in composite long-wall gobs. The results included the oxygen concentration distributions and temperature profiles showed that the numerical approach is validated by comparison with the test data. Furthermore, under the conditions of specific engineering, the major locations where some techniques for extinguishing and preventing long-wall gob fires need to be put into practice were also examined.

Keywords: computational simulation, UDEC simulation, coal self-heating, CFD modeling, long-wall gobs

Procedia PDF Downloads 278