Search results for: IEEE standard Test System
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 27555

Search results for: IEEE standard Test System

27285 Internet of Things for Smart Dedicated Outdoor Air System in Buildings

Authors: Dararat Tongdee, Surapong Chirarattananon, Somchai Maneewan, Chantana Punlek

Abstract:

Recently, the Internet of Things (IoT) is the important technology that connects devices to the network and people can access real-time communication. This technology is used to report, collect, and analyze the big data for achieving a purpose. For a smart building, there are many IoT technologies that enable management and building operators to improve occupant thermal comfort, indoor air quality, and building energy efficiency. In this research, we propose monitoring and controlling performance of a smart dedicated outdoor air system (SDOAS) based on IoT platform. The SDOAS was specifically designed with the desiccant unit and thermoelectric module. The designed system was intended to monitor, notify, and control indoor environmental factors such as temperature, humidity, and carbon dioxide (CO₂) level. The SDOAS was tested under the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 62.2) and indoor air quality standard. The system will notify the user by Blynk notification when the status of the building is uncomfortable or tolerable limits are reached according to the conditions that were set. The user can then control the system via a Blynk application on a smartphone. The experimental result indicates that the temperature and humidity of indoor fresh air in the comfort zone are approximately 26 degree Celsius and 58% respectively. Furthermore, the CO₂ level was controlled lower than 1000 ppm by indoor air quality standard condition. Therefore, the proposed system can efficiently work and be easy to use for buildings.

Keywords: internet of things, indoor air quality, smart dedicated outdoor air system, thermal comfort

Procedia PDF Downloads 171
27284 Reconciling the Modern Standard Arabic with the Local Dialects in Writing Literary Texts

Authors: Ahmed M. Ghaleb, Ehab S. Al-Nuzaili

Abstract:

This paper attempts to shed light on the question of the choice between standard Arabic and the vernacular in writing literary texts. Modern Standard Arabic (MSA) has long been the formal language of writing education, administration, and media, shred across the Arab countries. In the mid-20th century, some writers have begun to write their literary works in local dialects claiming that they can be more realistic. On the other hand, other writers have opposed this new trend as it can be a threat to the Standard Arabic or MSA that unify all Arabs. However, some other writers, like Tawfiq al-Hakim, Hamed Damanhouri, Najib Mahfouz, and Hanna Mineh, attempted to solve this problem by using what W. M. Hutchins called a 'hybrid language', a middle language between the standard and the vernacular. It is also termed 'a third language'. The paper attempts to examine some of the literary texts in which a combination of the standard and the colloquial is employed. Thus, the paper attempts to find out a solution by proposing a third language, a form that can combine the MSA and the colloquial, and the possibility of using it in writing literary texts. Therefore, the paper can bridge the gap between the different levels of Arabic.

Keywords: modern standard arabic, dialect or vernacular, diglossia, third language

Procedia PDF Downloads 100
27283 Design of Intelligent Scaffolding Learning Management System for Vocational Education

Authors: Seree Chadcham, Niphon Sukvilai

Abstract:

This study is the research and development which is intended to: 1) design of the Intelligent Scaffolding Learning Management System (ISLMS) for vocational education, 2) assess the suitability of the Design of Intelligent Scaffolding Learning Management System for Vocational Education. Its methods are divided into 2 phases. Phase 1 is the design of the ISLMS for Vocational Education and phase 2 is the assessment of the suitability of the design. The samples used in this study are work done by 15 professionals in the field of Intelligent Scaffolding, Learning Management System, Vocational Education, and Information and Communication Technology in education selected using the purposive sampling method. Data analyzed by arithmetic mean and standard deviation. The results showed that the ISLMS for vocational education consists of 2 main components which are: 1) the Intelligent Learning Management System for Vocational Education, 2) the Intelligent Scaffolding Management System. The result of the system suitability assessment from the professionals is in the highest range.

Keywords: intelligent, scaffolding, learning management system, vocational education

Procedia PDF Downloads 766
27282 Investigations into Effect of Neural Network Predictive Control of UPFC for Improving Transient Stability Performance of Multimachine Power System

Authors: Sheela Tiwari, R. Naresh, R. Jha

Abstract:

The paper presents an investigation into the effect of neural network predictive control of UPFC on the transient stability performance of a multi-machine power system. The proposed controller consists of a neural network model of the test system. This model is used to predict the future control inputs using the damped Gauss-Newton method which employs ‘backtracking’ as the line search method for step selection. The benchmark 2 area, 4 machine system that mimics the behavior of large power systems is taken as the test system for the study and is subjected to three phase short circuit faults at different locations over a wide range of operating conditions. The simulation results clearly establish the robustness of the proposed controller to the fault location, an increase in the critical clearing time for the circuit breakers and an improved damping of the power oscillations as compared to the conventional PI controller.

Keywords: identification, neural networks, predictive control, transient stability, UPFC

Procedia PDF Downloads 352
27281 Optimal Capacitors Placement and Sizing Improvement Based on Voltage Reduction for Energy Efficiency

Authors: Zilaila Zakaria, Muhd Azri Abdul Razak, Muhammad Murtadha Othman, Mohd Ainor Yahya, Ismail Musirin, Mat Nasir Kari, Mohd Fazli Osman, Mohd Zaini Hassan, Baihaki Azraee

Abstract:

Energy efficiency can be realized by minimizing the power loss with a sufficient amount of energy used in an electrical distribution system. In this report, a detailed analysis of the energy efficiency of an electric distribution system was carried out with an implementation of the optimal capacitor placement and sizing (OCPS). The particle swarm optimization (PSO) will be used to determine optimal location and sizing for the capacitors whereas energy consumption and power losses minimization will improve the energy efficiency. In addition, a certain number of busbars or locations are identified in advance before the PSO is performed to solve OCPS. In this case study, three techniques are performed for the pre-selection of busbar or locations which are the power-loss-index (PLI). The particle swarm optimization (PSO) is designed to provide a new population with improved sizing and location of capacitors. The total cost of power losses, energy consumption and capacitor installation are the components considered in the objective and fitness functions of the proposed optimization technique. Voltage magnitude limit, total harmonic distortion (THD) limit, power factor limit and capacitor size limit are the parameters considered as the constraints for the proposed of optimization technique. In this research, the proposed methodologies implemented in the MATLAB® software will transfer the information, execute the three-phase unbalanced load flow solution and retrieve then collect the results or data from the three-phase unbalanced electrical distribution systems modeled in the SIMULINK® software. Effectiveness of the proposed methods used to improve the energy efficiency has been verified through several case studies and the results are obtained from the test systems of IEEE 13-bus unbalanced electrical distribution system and also the practical electrical distribution system model of Sultan Salahuddin Abdul Aziz Shah (SSAAS) government building in Shah Alam, Selangor.

Keywords: particle swarm optimization, pre-determine of capacitor locations, optimal capacitors placement and sizing, unbalanced electrical distribution system

Procedia PDF Downloads 401
27280 Analyzing the Visual Capability of the Siberian Husky Breed of the Common Dog (Canis lupus familiaris) to Detect Terminally-Ill Patients Undergoing Palliative Care

Authors: Maximo Cozzetti

Abstract:

The aim is to evaluate the capability of the 'Siberian Husky' (FCI-Standard Nº 270) breed of the common dog (Canis lupus familiaris) to detect terminally-ill human patients undergoing palliative care. A total of 49 such patients that fulfill the 'National Scientific and Technical Research Council–Ethical Principles for the Behavior of the Scientific and Technical Investigator' policy, (mainly affected with Stage IV Hodgkin lymphoma or Stage IV Carcinoma, though various other terminal diseases were present) and 49 controls were enrolled. A total of 13 specimens of Siberian Huskies (Canis lupus familiaris FCI – Standard Nº 270) were selected. After a conditioning training regime in which the canines were rewarded when identifying terminally ill patients and excluding the control subjects, a double-blind experiment was conducted in which the canines were presented with a previously unknown patient through an olfactory-proof plexiglass window for 2-minute intervals. The test subjects correctly identified 89.80% of the humans as either ‘ill’ or ‘healthy’. It is important to note that both groups of humans were selected considering and preventing confounding and self-identifying factors such as age, ethnicity, clothing, posture, skin color, alopecia (chemotherapy-induced or otherwise), etc. The olfactory-proofing of the test area rules out the use of the sense of smell to detect distinctive drugs or bodily odors that may be associated with terminal diseases. Thus, the Siberian Husky breed of the common dog shows the visual capability to detect and identify terminally ill patients undergoing palliative care regardless of age, posture, and quantity of hair. Though the capability of the breed of dog to detect terminally-ill patients was observed thoroughly during the course of the experiments, the exact process by which the canines identify the test subjects remains unknown and further research is encouraged.

Keywords: Canis lupus familiaris, Siberian Husky, visual identification of terminall illness, FCI-Standard Nº270

Procedia PDF Downloads 133
27279 A Simple Olfactometer for Odour and Lateralization Thresholds of Chemical Vapours

Authors: Lena Ernstgård, Aishwarya M. Dwivedi, Johan Lundström, Gunnar Johanson

Abstract:

A simple inexpensive olfactometer was constructed to enable valid measures of detection threshold of low concentrations of vapours of chemicals. The delivery system consists of seven syringe pumps, each connected to a Tedlar bag containing a predefined concentration of the test chemical in the air. The seven pumps are connected to a 8-way mixing valve which in turn connects to a birhinal nose piece. Chemical vapor of known concentration is generated by injection of an appropriate amount of the test chemical into a Tedlar bag with a known volume of clean air. Complete vaporization is assured by gentle heating of the bag from the outside with a heat flow. The six test concentrations are obtained by adding different volumes from the starting bag to six new Tedlar bags with known volumes of clean air. One bag contains clean air only. Thus, six different test concentrations and clean air can easily be tested in series by shifting the valve to new positions. Initial in-line measurement with a photoionization detector showed that the delivery system quickly responded to a shift in valve position. Thus 90% of the desired concentration was reached within 15 seconds. The concentrations in the bags are verified daily by gas chromatography. The stability of the system in terms of chemical concentration is monitored in real time by means of a photo-ionization detector. To determine lateralization thresholds, an additional pump supplying clean air is added to the delivery system in a way so that the nostrils can be separately and interchangeably be exposed to clean air and test chemical. Odor and lateralization thresholds were determined for three aldehydes; acrolein, crotonaldehyde, and hexanal in 20 healthy naïve individuals. Aldehydes generally have a strong odour, and the selected aldehydes are also considered to be irritating to mucous membranes. The median odor thresholds of the three aldehydes were 0.017, 0.0008, and 0.097 ppm, respectively. No lateralization threshold could be identified for acrolein, whereas the medians for crotonaldehyde and hexanal were 0.003 and 0.39 ppm, respectively. In conclusion, we constructed a simple, inexpensive olfactometer that allows for stable and easily measurable concentrations of vapors of the test chemical. Our test with aldehydes demonstrates that the system produces valid detection among volunteers in terms of odour and lateralization thresholds.

Keywords: irritation, odour delivery, olfactometer, smell

Procedia PDF Downloads 193
27278 Analyzing the Quality of Cloud-Based E-Learning Systems on the Perception of the Learners and the Teachers

Authors: R. W. C. Devindi, S. M. Buddika Harshanath

Abstract:

E-learning is a widely used technology for learning in the modern world. With the pandemic situation the popularity of using e-learning has been increased in a larger capacity. The e-learning educational systems require software resources as well as hardware usually but it is hard for most of the education institutions to afford those resources. Also with the massive user load e-learning has to broaden the server side resources as well. Therefore, in the present cloud computing was implemented in order to make the e – learning systems more efficient. The researcher has analyzed the quality of the e-learning systems on the perception of the learners and the teachers with the aid of hypothesis and has given the analyzed results and the discussion in this report. Therefore, the future research will be able to get some steps to increase the quality of the online learning systems furthermore. In the case of e-learning, quality assurance and cost effectiveness are essential. A complex quality assurance system is used in the stated project. There are no well-defined standard evaluation measures in this field. As a result, accurately assessing the e-learning system's overall quality is challenging. The researcher has done the analysis with the aid of standard methods and software.

Keywords: LMS–learning management system, SPSS–statistical package for social sciences (software), eigen value, hypothesis

Procedia PDF Downloads 83
27277 NSBS: Design of a Network Storage Backup System

Authors: Xinyan Zhang, Zhipeng Tan, Shan Fan

Abstract:

The first layer of defense against data loss is the backup data. This paper implements an agent-based network backup system used the backup, server-storage and server-backup agent these tripartite construction, and we realize the snapshot and hierarchical index in the NSBS. It realizes the control command and data flow separation, balances the system load, thereby improving the efficiency of the system backup and recovery. The test results show the agent-based network backup system can effectively improve the task-based concurrency, reasonably allocate network bandwidth, the system backup performance loss costs smaller and improves data recovery efficiency by 20%.

Keywords: agent, network backup system, three architecture model, NSBS

Procedia PDF Downloads 429
27276 Evaluation of the Relation between Serum and Saliva Levels of Sodium and Glucose in Healthy Referred Patients to Tabriz Faculty of Dentistry

Authors: Samaneh Nazemi, Ayla Bahramian, Marzieh Aghazadeh

Abstract:

Saliva is a clear liquid composed of water, electrolytes, glucose, amylase, glycoproteins, and antimicrobial enzymes. The presence of a wide range of molecules and proteins in saliva has made this fluid valuable in screening for some diseases as well as epidemiological studies. Saliva is easier than serum to collect in large populations. Due to the importance of sodium and glucose levels in many biological processes, this study investigates the relationship between sodium and glucose levels in salivary and serum samples of healthy individuals referring to Tabriz Dental School. This descriptive-analytical study was performed on 40 healthy individuals referred to the Oral Diseases Department of Tabriz Dental School. Serum and saliva samples were taken from these patients according to standard protocols. Data were presented as mean (standard deviation) and frequency (percentage) for quantitative and qualitative variables. Pearson test, paired-samples T-test and SPSS 24 software were used to determine the correlation between serum and salivary levels of these biomarkers. In this study, P less than 0.05% is considered significant. Out of 40 participants in this study, 14 (35%) were male, and 26 (65%) were female. According to the results of this study, the mean salivary sodium (127.53 ml/dl) was lower than the mean serum sodium (141.2725 ml/dl). In contrast, the mean salivary glucose (4.55 ml/dl) was lower than the mean serum glucose (89.7575 ml/dl). The result of paired samples T-test (p-value<0.05) showed that there is a statistically significant difference between the mean of serum sodium and salivary sodium, as well as between the serum glucose and salivary glucose. Pearson correlation test results showed that there is no significant correlation between serum sodium and salivary sodium (p-value >0.05), but here is a positive correlation between serum glucose and salivary glucose (p-value<0.001). Both serum sodium and glucose were higher than salivary sodium and glucose.In conclusion, this study found that there was not a statistical relationship between salivary glucose and serum glucose and also salivary sodium and serum sodium of healthy individuals. Perhaps salivary samples can’t be used to measure glucose and sodium in these individuals.

Keywords: glucose, saliva, serum, sodium

Procedia PDF Downloads 223
27275 Synthesis and Characterisation of Starch-PVP as Encapsulation Material for Drug Delivery System

Authors: Nungki Rositaningsih, Emil Budianto

Abstract:

Starch has been widely used as an encapsulation material for drug delivery system. However, starch hydrogel is very easily degraded during metabolism in human stomach. Modification of this material is needed to improve the encapsulation process in drug delivery system, especially for gastrointestinal drug. In this research, three modified starch-based hydrogels are synthesized i.e. Crosslinked starch hydrogel, Semi- and Full- Interpenetrating Polymer Network (IPN) starch hydrogel using Poly(N-Vinyl-Pyrrolidone). Non-modified starch hydrogel was also synthesized as a control. All of those samples were compared as biomaterials, floating drug delivery, and their ability in loading drug test. Biomaterial characterizations were swelling test, stereomicroscopy observation, Differential Scanning Calorimetry (DSC), and Fourier Transform Infrared Spectroscopy (FTIR). Buoyancy test and stereomicroscopy scanning were done for floating drug delivery characterizations. Lastly, amoxicillin was used as test drug, and characterized with UV-Vis spectroscopy for loading drug observation. Preliminary observation showed that Full-IPN has the most dense and elastic texture, followed by Semi-IPN, Crosslinked, and Non-modified in the last position. Semi-IPN and Crosslinked starch hydrogel have the most ideal properties and will not be degraded easily during metabolism. Therefore, both hydrogels could be considered as promising candidates for encapsulation material. Further analysis and issues will be discussed in the paper.

Keywords: biomaterial, drug delivery system, interpenetrating polymer network, poly(N-vinyl-pyrrolidone), starch hydrogel

Procedia PDF Downloads 223
27274 Multistage Adomian Decomposition Method for Solving Linear and Non-Linear Stiff System of Ordinary Differential Equations

Authors: M. S. H. Chowdhury, Ishak Hashim

Abstract:

In this paper, linear and non-linear stiff systems of ordinary differential equations are solved by the classical Adomian decomposition method (ADM) and the multi-stage Adomian decomposition method (MADM). The MADM is a technique adapted from the standard Adomian decomposition method (ADM) where standard ADM is converted into a hybrid numeric-analytic method called the multistage ADM (MADM). The MADM is tested for several examples. Comparisons with an explicit Runge-Kutta-type method (RK) and the classical ADM demonstrate the limitations of ADM and promising capability of the MADM for solving stiff initial value problems (IVPs).

Keywords: stiff system of ODEs, Runge-Kutta Type Method, Adomian decomposition method, Multistage ADM

Procedia PDF Downloads 402
27273 E-Vet Smart Rapid System: Detection of Farm Disease Based on Expert System as Supporting to Epidemic Disesase Control

Authors: Malik Abdul Jabbar Zen, Wiwik Misaco Yuniarti, Azisya Amalia Karimasari, Novita Priandini

Abstract:

Zoonos is as an infectiontransmitted froma nimals to human sand vice versa currently having increased in the last 20 years. The experts/scientists predict that zoonosis will be a threat to the community in the future since it leads on 70% emerging infectious diseases (EID) and the high mortality of 50%-90%. The zoonosis’ spread from animal to human is caused by contaminated food known as foodborne disease. One World One Health, as the conceptual prevention toward zoonosis, requires the crossed disciplines cooperation to accelerate and streamlinethe handling ofanimal-based disease. E-Vet Smart Rapid System is an integrated innovation in the veterinary expertise application is able to facilitate the prevention, treatment, and educationagainst pandemic diseases and zoonosis. This system is constructed by Decision Support System (DSS) method provides a database of knowledge that is expected to facilitate the identification of disease rapidly, precisely, and accurately as well as to identify the deduction. The testingis conducted through a black box test case and questionnaire (N=30) by validity and reliability approach. Based on the black box test case reveals that E-Vet Rapid System is able to deliver the results in accordance with system design, and questionnaire shows that this system is valid (r > 0.361) and has a reliability (α > 0.3610).

Keywords: diagnosis, disease, expert systems, livestock, zoonosis

Procedia PDF Downloads 423
27272 Resilience Perspective on Response Strategies for Super-Standard Rain and Flood Disasters: A Case Study of the “Zhengzhou 7.20 Heavy Rain” Event

Authors: Luojie Tang

Abstract:

The article takes the "7.20 Heavy Rainstorm in Zhengzhou" as a starting point, collects relevant disaster data, reproduces the entire process of the disaster, and identifies the main problems exposed by the city in responding to super-standard rain and flood disasters. Based on the review of resilience theory, the article proposes a shift in thinking about the response to super-standard rain and flood disasters from the perspective of resilience, clarifies the differences in the emphasis on resilience at different stages of disasters, and preliminarily constructs a response system for super-standard rain and flood disasters based on the guidance of resilience theory. Finally, combined with the highlighted problems in the 7.20 Heavy Rainstorm in Zhengzhou, the article proposes targeted response strategies from three perspectives: institutional management, technological support, and infrastructure, under the perspective of resilience.

Keywords: resilient city, exceedance-based stormwater management, disaster risk reduction, megalopolis

Procedia PDF Downloads 67
27271 Evaluation of the Irritation Potential of Three Topical Formulations of Minoxidil 5% Using Patch Test

Authors: Sule Pallavi, Shah Priyank, Thavkar Amit, Mehta Suyog, Rohira Poonam

Abstract:

Minoxidil is used topically to help hair growth in the treatment of male androgenetic alopecia. The objective of this study is to compare irritation potential of three conventional formulation of minoxidil 5% topical solution of in human patch test. The study was a single centre, double blind, non-randomized controlled study in 56 healthy adult Indian subjects. Occlusive patch test for 24 hours was performed with three formulation of minoxidil 5% topical solution. Products tested included aqueous based minoxidil 5% (AnasureTM 5%, Sun Pharma, India – Brand A), alcohol based minoxidil 5% (Brand B) and aqueous based minoxidil 5% (Brand C). Isotonic saline 0.9% and 1% w/w sodium lauryl sulphate were included as negative control and positive control respectively. Patches were applied and removed after 24hours. The skin reaction was assessed and clinically scored 24 hours after the removal of the patches under constant artificial daylight source using Draize scale (0-4 points scale for erythema/wrinkles/dryness and for oedema). A combined mean score up to 2.0/8.0 indicates a product is “non-irritant” and score between 2.0/8.0 and 4.0/8.0 indicates “mildly irritant” and score above 4.0/8.0 indicates “irritant”. Follow-up was scheduled after one week to confirm recovery for any reaction. The procedure of the patch test followed the principles outlined by Bureau of Indian standards (BIS) (IS 4011:2018; Methods of Test for safety evaluation of Cosmetics-3rd revision). Fifty six subjects with mean age 30.9 years (27 males and 29 females) participated in the study. The combined mean score (± standard deviation) were: 0.13 ± 0.33 (Brand A), 0.39 ± 0.49 (Brand B), 0.22 ± 0.41 (Brand C), 2.91 ± 0.79 (Positive control) and 0.02 ± 0.13 (Negative control). The mean score of Brand A (Sun Pharma product) was significantly lower than Brand B (p=0.001) and was comparable with Brand C (p=0.21). The combined mean erythema score (± standard deviation) were: 0.09 ± 0.29 (Brand A), 0.27 ± 0.5 (Brand B), 0.18 ± 0.39 (Brand C), 2.02 ± 0.49 (Positive control) and 0.0 ± 0.0 (Negative control). The mean erythema score of Brand A was significantly lower than Brand B (p=0.01) and was comparable with Brand C (p=0.16). Any reaction observed at 24hours after patch removal subsided in a week. All the three topical formulation of minoxidil 5% were non-irritant. Brand A of 5% minoxidil (Sun Pharma) was found to be least irritant than Brand B and Brand C based on the combined mean score and mean erythema score in the human patch test as per the BIS, IS 4011;2018.

Keywords: erythema, irritation, minoxidil, patch test

Procedia PDF Downloads 76
27270 Internal Audit and the Effectiveness and Efficiency of Operations in Hospitals

Authors: Naziru Suleiman

Abstract:

The ever increasing cases of financial frauds and corporate accounting scandals in recent years have raised more concern on the operation of internal control mechanisms and performance of the internal audit departments in organizations. In most cases the seeming presence of both the internal control system and internal audit in organizations do not prove useful as frauds errors and irregularities are being perpetuated. The aim of this study, therefore, is to assess the role of internal audit in achieving the objectives of internal control system of federal hospitals in Kano State from the perception of the respondents. The study used survey research design and generated data from primary source by means of questionnaire. A total number of 100 copies of questionnaire were administered out of which 68 were duly completed and returned. Cronbach’s alpha was used to test the internal validity of the various items in the constructs. Descriptive statistics, chi-square test, Mann Whitney U test and Kruskal Wallis ANOVA were employed for the analysis of data. The study finds that from the perception of the respondents, internal audit departments in Federal Hospitals in Kano State are effective and that they contribute positively to the overall attainment of the objectives of internal control system of these hospitals. There is no significant difference found on the views of the respondents from the three hospitals. Hence, the study concludes that strong and functional internal audit department is a basic requirement for effectiveness of operations of the internal control system. In the light of the findings, it is recommended that internal audit should continue to ensure that the objectives of internal control system of these hospitals are achieved through proper and adequate evaluation and review of the system.

Keywords: internal audit, internal control, federal hospitals, financial frauds

Procedia PDF Downloads 319
27269 Corruption, Tax Systems and Inclusive Development

Authors: Lawrence Kwaku Amoako, Parrendah Adwoa Kpeli

Abstract:

This paper analyses the implications of the corruption and tax system on inclusive development. We employ a sample of 45 countries between 2007 and 2020. We test for two related hypotheses; first, corruption hinders the smooth mobilisation of revenue through the tax system. Second, a rise in corruption amidst a defective tax system impairs inclusive development. We expect that a rise in the level of corruption in the economy will distort the tax system, thus affecting efficient revenue mobilisation and, subsequently, inclusive development. By extension, these findings have important policy implications for governments in containing corruption and building an effective tax system as it will help promote inclusive development.

Keywords: corruption, development, tax systems, tax complexity

Procedia PDF Downloads 80
27268 Factors Affecting Test Automation Stability and Their Solutions

Authors: Nagmani Lnu

Abstract:

Test automation is a vital requirement of any organization to release products faster to their customers. In most cases, an organization has an approach to developing automation but struggles to maintain it. It results in an increased number of Flaky Tests, reducing return on investments and stakeholders’ confidence. Challenges grow in multiple folds when automation is for UI behaviors. This paper describes the approaches taken to identify the root cause of automation instability in an extensive payments application and the best practices to address that using processes, tools, and technologies, resulting in a 75% reduction of effort.

Keywords: automation stability, test stability, Flaky Test, test quality, test automation quality

Procedia PDF Downloads 43
27267 Optimal Wind Based DG Placement Considering Monthly Changes Modeling in Wind Speed

Authors: Belal Mohamadi Kalesar, Raouf Hasanpour

Abstract:

Proper placement of Distributed Generation (DG) units such as wind turbine generators in distribution system are still very challenging issue for obtaining their maximum potential benefits because inappropriate placement may increase the system losses. This paper proposes Particle Swarm Optimization (PSO) technique for optimal placement of wind based DG (WDG) in the primary distribution system to reduce energy losses and voltage profile improvement with four different wind levels modeling in year duration. Also, wind turbine is modeled as a DFIG that will be operated at unity power factor and only one wind turbine tower will be considered to install at each bus of network. Finally, proposed method will be implemented on widely used 69 bus power distribution system in MATLAB software environment under four scenario (without, one, two and three WDG units) and for capability test of implemented program it is supposed that all buses of standard system can be candidate for WDG installing (large search space), though this program can consider predetermined number of candidate location in WDG placement to model financial limitation of project. Obtained results illustrate that wind speed increasing in some months will increase output power generated but this can increase / decrease power loss in some wind level, also results show that it is required about 3MW WDG capacity to install in different buses but when this is distributed in overall network (more number of WDG) it can cause better solution from point of view of power loss and voltage profile.

Keywords: wind turbine, DG placement, wind levels effect, PSO algorithm

Procedia PDF Downloads 421
27266 Modeling and Simulation Methods Using MATLAB/Simulink

Authors: Jamuna Konda, Umamaheswara Reddy Karumuri, Sriramya Muthugi, Varun Pishati, Ravi Shakya,

Abstract:

This paper investigates the challenges involved in mathematical modeling of plant simulation models ensuring the performance of the plant models much closer to the real time physical model. The paper includes the analysis performed and investigation on different methods of modeling, design and development for plant model. Issues which impact the design time, model accuracy as real time model, tool dependence are analyzed. The real time hardware plant would be a combination of multiple physical models. It is more challenging to test the complete system with all possible test scenarios. There are possibilities of failure or damage of the system due to any unwanted test execution on real time.

Keywords: model based design (MBD), MATLAB, Simulink, stateflow, plant model, real time model, real-time workshop (RTW), target language compiler (TLC)

Procedia PDF Downloads 319
27265 Investigation for the Mechanism of Lateral-Torsional Coupled Vibration of the Propulsion Shaft in a Ship

Authors: Hyungsuk Han, Soohong Jeon, Chungwon Lee, YongHoon Kim

Abstract:

When a rubber mount and flexible coupling are installed on the main engine, high torsional vibration can occur. The root cause of this high torsional vibration can be attributed to the lateral-torsional coupled vibration of the shaft system. Therefore, the lateral-torsional coupled vibration is investigated numerically after approximating the shaft system to a three-degrees-of-freedom Jeffcott rotor. To verify that the high torsional vibration is caused by the lateral-torsional coupled vibration, a test unit that can simulate this lateral-torsional coupled vibration occurring in the propulsion shaft is developed. Performing a vibration test with the test unit, it can be experimentally verified that the high torsional vibration occurring in the propulsion shaft of the particular ship was caused by the lateral-torsional coupled vibration.

Keywords: Jeffcott rotor, lateral-torsional coupled vibration, propulsion shaft, stability

Procedia PDF Downloads 200
27264 Neuropsychological Testing in a Multi-Lingual Society: Normative Data for South African Adults in More Than Eight Languages

Authors: Sharon Truter, Ann B. Shuttleworth-Edwards

Abstract:

South Africa is a developing country with significant diversity in languages spoken and quality of education available, creating challenges for fair and accurate neuropsychological assessments when most available neuropsychological tests are obtained from English-speaking developed countries. The aim of this research was to compare normative data on a spectrum of commonly used neuropsychological tests for English- and Afrikaans-speaking South Africans with relatively high quality of education and South Africans with relatively low quality of education who speak Afrikaans, Sesotho, Setswana, Sepedi, Tsonga, Venda, Xhosa or Zulu. The participants were all healthy adults aged 18-60 years, with 8-12 years of education. All the participants were tested in their first language on the following tests: two non-verbal tests (Rey Osterrieth Complex Figure Test and Bell Cancellation Test), four verbal fluency tests (category, phonemic, verb and 'any words'), one verbal learning test (Rey Auditory Verbal Leaning Test) and three tests that have a verbal component (Trail Making Test A & B; Symbol Digit Modalities Test and Digit Span). Descriptive comparisons of mean scores and standard deviations across the language groups and between the groups with relatively high versus low quality of education highlight the importance of using normative data that takes into account language and quality of education.

Keywords: cross-cultural, language, multi-lingual, neuropsychological testing, quality of education

Procedia PDF Downloads 126
27263 Towards an Intelligent Ontology Construction Cost Estimation System: Using BIM and New Rules of Measurement Techniques

Authors: F. H. Abanda, B. Kamsu-Foguem, J. H. M. Tah

Abstract:

Construction cost estimation is one of the most important aspects of construction project design. For generations, the process of cost estimating has been manual, time-consuming and error-prone. This has partly led to most cost estimates to be unclear and riddled with inaccuracies that at times lead to over- or under-estimation of construction cost. The development of standard set of measurement rules that are understandable by all those involved in a construction project, have not totally solved the challenges. Emerging Building Information Modelling (BIM) technologies can exploit standard measurement methods to automate cost estimation process and improves accuracies. This requires standard measurement methods to be structured in ontologically and machine readable format; so that BIM software packages can easily read them. Most standard measurement methods are still text-based in textbooks and require manual editing into tables or Spreadsheet during cost estimation. The aim of this study is to explore the development of an ontology based on New Rules of Measurement (NRM) commonly used in the UK for cost estimation. The methodology adopted is Methontology, one of the most widely used ontology engineering methodologies. The challenges in this exploratory study are also reported and recommendations for future studies proposed.

Keywords: BIM, construction projects, cost estimation, NRM, ontology

Procedia PDF Downloads 513
27262 Application of Universal Distribution Factors for Real-Time Complex Power Flow Calculation

Authors: Abdullah M. Alodhaiani, Yasir A. Alturki, Mohamed A. Elkady

Abstract:

Complex power flow distribution factors, which relate line complex power flows to the bus injected complex powers, have been widely used in various power system planning and analysis studies. In particular, AC distribution factors have been used extensively in the recent power and energy pricing studies in free electricity market field. As was demonstrated in the existing literature, many of the electricity market related costing studies rely on the use of the distribution factors. These known distribution factors, whether the injection shift factors (ISF’s) or power transfer distribution factors (PTDF’s), are linear approximations of the first order sensitivities of the active power flows with respect to various variables. This paper presents a novel model for evaluating the universal distribution factors (UDF’s), which are appropriate for an extensive range of power systems analysis and free electricity market studies. These distribution factors are used for the calculations of lines complex power flows and its independent of bus power injections, they are compact matrix-form expressions with total flexibility in determining the position on the line at which line flows are measured. The proposed approach was tested on IEEE 9-Bus system. Numerical results demonstrate that the proposed approach is very accurate compared with exact method.

Keywords: distribution factors, power system, sensitivity factors, electricity market

Procedia PDF Downloads 438
27261 A Field Study of Monochromatic Light Effects on Antibody Responses to Newcastle Disease by HI Test and the Correlation with ELISA

Authors: Seyed Mehrzad Pahlavani, Mozaffar Haji Jafari Anaraki, Sayma Mohammadi

Abstract:

A total of 34700 day-old broilers were exposed to green, blue and yellow light using a light-emitting diode system for 6 weeks to investigate the effects of light wave length on antibody responses to Newcastle disease by HI test and the correlation with ELISA. 3 poultry house broiler farms with the same conditions was selected and the lightening system of each was set according to the requirement. Blood samples were taken from 20 chicks on days 1, 24 and 46 and the Newcastle virus specific antibody was titered in serum using HI an ELISA test. On day 24, the probability value of more than 0/05 was observed in HI and ELISA tests of all groups while at the end of breeding period, the average HI serum antibody titer was more in the green light than the yellow one while the blue light was not significantly different from both. At the last titration, the green light has got the highest titer of Newcastle antibodies. There were no significant differences of Newcastle antibody titers between all groups and ages in broiler pullets in ELISA. According to the sampling and analysis of HI and ELISA serum tests, there were no significant relationships between all broiler pullets breeding in green, blue and yellow light on days 24 and 46 and the P-value was more than 0/05. It is suggested that the monochromatic light is effective on broilers immunity against Newcastle disease.

Keywords: monochromatic light, Newcastle disease, HI test, ELISA test

Procedia PDF Downloads 632
27260 Throughput of Point Coordination Function (PCF)

Authors: Faisel Eltuhami Alzaalik, Omar Imhemed Alramli, Ahmed Mohamed Elaieb

Abstract:

The IEEE 802.11 defines two modes of MAC, distributed coordination function (DCF) and point coordination function (PCF) mode. The first sub-layer of the MAC is the distributed coordination function (DCF). A contention algorithm is used via DCF to provide access to all traffic. The point coordination function (PCF) is the second sub-layer used to provide contention-free service. PCF is upper DCF and it uses features of DCF to establish guarantee access of its users. Some papers and researches that have been published in this technology were reviewed in this paper, as well as talking briefly about the distributed coordination function (DCF) technology. The simulation of the PCF function have been applied by using a simulation program called network simulator (NS2) and have been found out the throughput of a transmitter system by using this function.

Keywords: DCF, PCF, throughput, NS2

Procedia PDF Downloads 540
27259 Performance Monitoring and Environmental Impact Analysis of a Photovoltaic Power Plant: A Numerical Modeling Approach

Authors: Zahzouh Zoubir

Abstract:

The widespread adoption of photovoltaic panel systems for global electricity generation is a prominent trend. Algeria, demonstrating steadfast commitment to strategic development and innovative projects for harnessing solar energy, emerges as a pioneering force in the field. Heat and radiation, being fundamental factors in any solar system, are currently subject to comprehensive studies aiming to discern their genuine impact on crucial elements within photovoltaic systems. This endeavor is particularly pertinent given that solar module performance is exclusively assessed under meticulously defined Standard Test Conditions (STC). Nevertheless, when deployed outdoors, solar modules exhibit efficiencies distinct from those observed under STC due to the influence of diverse environmental factors. This discrepancy introduces ambiguity in performance determination, especially when surpassing test conditions. This article centers on the performance monitoring of an Algerian photovoltaic project, specifically the Oued El Keberite power (OKP) plant boasting a 15 megawatt capacity, situated in the town of Souk Ahras in eastern Algeria. The study elucidates the behavior of a subfield within this facility throughout the year, encompassing various conditions beyond the STC framework. To ensure the optimal efficiency of solar panels, this study integrates crucial factors, drawing on an authentic technical sheet from the measurement station of the OKP photovoltaic plant. Numerical modeling and simulation of a sub-field of the photovoltaic station were conducted using MATLAB Simulink. The findings underscore how radiation intensity and temperature, whether low or high, impact the short-circuit current, open-circuit voltage; fill factor, and overall efficiency of the photovoltaic system.

Keywords: performance monitoring, photovoltaic system, numerical modeling, radiation intensity

Procedia PDF Downloads 35
27258 Design of a Standard Weather Data Acquisition Device for the Federal University of Technology, Akure Nigeria

Authors: Isaac Kayode Ogunlade

Abstract:

Data acquisition (DAQ) is the process by which physical phenomena from the real world are transformed into an electrical signal(s) that are measured and converted into a digital format for processing, analysis, and storage by a computer. The DAQ is designed using PIC18F4550 microcontroller, communicating with Personal Computer (PC) through USB (Universal Serial Bus). The research deployed initial knowledge of data acquisition system and embedded system to develop a weather data acquisition device using LM35 sensor to measure weather parameters and the use of Artificial Intelligence(Artificial Neural Network - ANN)and statistical approach(Autoregressive Integrated Moving Average – ARIMA) to predict precipitation (rainfall). The device is placed by a standard device in the Department of Meteorology, Federal University of Technology, Akure (FUTA) to know the performance evaluation of the device. Both devices (standard and designed) were subjected to 180 days with the same atmospheric condition for data mining (temperature, relative humidity, and pressure). The acquired data is trained in MATLAB R2012b environment using ANN, and ARIMAto predict precipitation (rainfall). Root Mean Square Error (RMSE), Mean Absolute Error (MAE), Correction Square (R2), and Mean Percentage Error (MPE) was deplored as standardize evaluation to know the performance of the models in the prediction of precipitation. The results from the working of the developed device show that the device has an efficiency of 96% and is also compatible with Personal Computer (PC) and laptops. The simulation result for acquired data shows that ANN models precipitation (rainfall) prediction for two months (May and June 2017) revealed a disparity error of 1.59%; while ARIMA is 2.63%, respectively. The device will be useful in research, practical laboratories, and industrial environments.

Keywords: data acquisition system, design device, weather development, predict precipitation and (FUTA) standard device

Procedia PDF Downloads 63
27257 Thermal Vacuum Chamber Test Result for CubeSat Transmitter

Authors: Fitri D. Jaswar, Tharek A. Rahman, Yasser A. Ahmad

Abstract:

CubeSat in low earth orbit (LEO) mainly uses ultra high frequency (UHF) transmitter with fixed radio frequency (RF) output power to download the telemetry and the payload data. The transmitter consumes large amount of electrical energy during the transmission considering the limited satellite size of a CubeSat. A transmitter with power control ability is designed to achieve optimize the signal to noise ratio (SNR) and efficient power consumption. In this paper, the thermal vacuum chamber (TVAC) test is performed to validate the performance of the UHF band transmitter with power control capability. The TVAC is used to simulate the satellite condition in the outer space environment. The TVAC test was conducted at the Laboratory of Spacecraft Environment Interaction Engineering, Kyushu Institute of Technology, Japan. The TVAC test used 4 thermal cycles starting from +60°C to -20°C for the temperature setting. The pressure condition inside chamber was less than 10-5Pa. During the test, the UHF transmitter is integrated in a CubeSat configuration with other CubeSat subsystem such as on board computer (OBC), power module, and satellite structure. The system is validated and verified through its performance in terms of its frequency stability and the RF output power. The UHF band transmitter output power is tested from 0.5W to 2W according the satellite mode of operations and the satellite power limitations. The frequency stability is measured and the performance obtained is less than 2 ppm in the tested operating temperature range. The test demonstrates the RF output power is adjustable in a thermal vacuum condition.

Keywords: communication system, CubeSat, SNR, UHF transmitter

Procedia PDF Downloads 233
27256 Coconut Shells as the Alternative Equipment for Foot Reflexology

Authors: Nichanant Sermsri, Chananchida Yuktirat

Abstract:

This research was the experimental research. Its purpose was to find out how coconut shells can be adapted to be equipment for foot and calf reflexology. The sample group was 58 female street vendors in Thewet Market, Dusit District, Bangkok, selected by selection criteria and voluntary. The data collecting tool in this research was the Visual Analogue Scale. The massaging tool made from coconut shells (designed and produced by the research team) was the key equipment for this research. The duration of the research was 1 month. The research team assessed the level of exhaustion and heart rate among sample group before and after the massage, then analyzed the data by mean, standard deviation and paired sample t-test. We found out from the research that 1) The level of exhaustion decreased 4.529 levels after the massage. The standard deviation was 1.6195. The heart rates went down 11.67 times/minute. The standard deviation was 6.742. 2) The level of exhaustion and heart rate after the massage decreased with the statistically significance at 0.01.

Keywords: foot reflexology, massaging plate, coconut shells, ecological sciences

Procedia PDF Downloads 165