14846 Frequency-Dependent and Full Range Tunable Phase Shifter

Authors: Yufu Yin, Tao Lin, Shanghong Zhao, Zihang Zhu, Xuan Li, Wei Jiang, Qiurong Zheng, Hui Wang

Abstract:

In this paper, a frequency-dependent and tunable phase shifter is proposed and numerically analyzed. The key devices are the dual-polarization binary phase shift keying modulator (DP-BPSK) and the fiber Bragg grating (FBG). The phase-frequency response of the FBG is employed to determine the frequency-dependent phase shift. The simulation results show that a linear phase shift of the recovered output microwave signal which depends on the frequency of the input RF signal is achieved. In addition, by adjusting the power of the RF signal, the full range phase shift from 0° to 360° can be realized. This structure shows the spurious free dynamic range (SFDR) of 70.90 dB·Hz2/3 and 72.11 dB·Hz2/3 under different RF powers.

Keywords: microwave photonics, phase shifter, spurious free dynamic range, frequency-dependent

Procedia PDF Downloads 296
14845 Slip Suppression Sliding Mode Control with Various Chattering Functions

Authors: Shun Horikoshi, Tohru Kawabe

Abstract:

This study presents performance analysis results of SMC (Sliding mode control) with changing the chattering functions applied to slip suppression problem of electric vehicles (EVs). In SMC, chattering phenomenon always occurs through high frequency switching of the control inputs. It is undesirable phenomenon and degrade the control performance, since it causes the oscillations of the control inputs. Several studies have been conducted on this problem by introducing some general saturation function. However, study about whether saturation function was really best and the performance analysis when using the other functions, weren’t being done so much. Therefore, in this paper, several candidate functions for SMC are selected and control performance of candidate functions is analyzed. In the analysis, evaluation function based on the trade-off between slip suppression performance and chattering reduction performance is proposed. The analyses are conducted in several numerical simulations of slip suppression problem of EVs. Then, we can see that there is no difference of employed candidate functions in chattering reduction performance. On the other hand, in slip suppression performance, the saturation function is excellent overall. So, we conclude the saturation function is most suitable for slip suppression sliding mode control.

Keywords: sliding mode control, chattering function, electric vehicle, slip suppression, performance analysis

Procedia PDF Downloads 326
14844 Monitoring of Spectrum Usage and Signal Identification Using Cognitive Radio

Authors: O. S. Omorogiuwa, E. J. Omozusi

Abstract:

The monitoring of spectrum usage and signal identification, using cognitive radio, is done to identify frequencies that are vacant for reuse. It has been established that ‘internet of things’ device uses secondary frequency which is free, thereby facing the challenge of interference from other users, where some primary frequencies are not being utilised. The design was done by analysing a specific frequency spectrum, checking if all the frequency stations that range from 87.5-108 MHz are presently being used in Benin City, Edo State, Nigeria. From the results, it was noticed that by using Software Defined Radio/Simulink, we were able to identify vacant frequencies in the range of frequency under consideration. Also, we were able to use the significance of energy detection threshold to reuse this vacant frequency spectrum, when the cognitive radio displays a zero output (that is decision H0), meaning that the channel is unoccupied. Hence, the analysis was able to find the spectrum hole and identify how it can be reused.

Keywords: spectrum, interference, telecommunication, cognitive radio, frequency

Procedia PDF Downloads 224
14843 The Effect of an e-Learning Program of Basic Cardiopulmonary Resuscitation for Students of an Emergency Medical Technician Program

Authors: Itsaree Padphai, Jiranan Pakpeian, Suksun Niponchai

Abstract:

This study is a descriptive research which aims to: 1) Compare the difference of knowledge before and after using the e-Learning program entitled “Basic Cardiopulmonary Resuscitation for Students in an Emergency Medical Technician Diploma Program”, and 2) Assess the students’ satisfaction after using the said program. This research is a kind of teaching and learning management supplemented with the e-Learning system; therefore, the purposively selected samples are 44 first-year and class-16 students of an emergency medical technician diploma program who attend the class in a second semester of academic year 2012 in Sirindhorn College of Public Health, Khon Kaen province. The research tools include 1) the questionnaire for general information of the respondents, 2) the knowledge tests before and after using the e-Learning program, and 3) an assessment of satisfaction in using the e-Learning program. The statistics used in data analysis percentage, include mean, standard deviation, and inferential statistics: paired t-test. 1. The general information of the respondents was mostly 37 females representing 84.09 percent. The average age was 19.5 years (standard deviation was 0.81), the maximum age was 21 years, and the minimum age was 19 years respectively. Students (35 subjects) admitted that they preferred the methods of teaching and learning by using the e-Learning systems. This was totally 79.95 percent. 2. A comparison on the difference of knowledge before and after using the e-Learning program showed that the mean before an application was 6.64 (standard deviation was 1.94) and after was 18.84 (standard deviation 1.03), which was higher than the knowledge of students before using the e-Learning program with the statistical significance (P value < 0.001). 3. For the satisfaction after using the e-Learning program, it was found that students’ satisfaction was at a very good level with the mean of 4.93 (standard deviation was 0.11).

Keywords: e-Learning, cardiopulmonary resuscitation, diploma program, Khon Kaen Province

Procedia PDF Downloads 399
14842 High Performance Direct Torque Control for Induction Motor Drive Fed from Photovoltaic System

Authors: E. E. EL-Kholy, Ahamed Kalas, Mahmoud Fauzy, M. El-Shahat Dessouki, Abdou M. El-refay, Mohammed El-Zefery

Abstract:

Direct Torque Control (DTC) is an AC drive control method especially designed to provide fast and robust responses. In this paper a progressive algorithm for direct torque control of three-phase induction drive system supplied by photovoltaic arrays using voltage source inverter to control motor torque and flux with maximum power point tracking at different level of insolation is presented. Experimental results of the new DTC method obtained by an experimental rapid prototype system for drives are presented. Simulation and experimental results confirm that the proposed system gives quick, robust torque and speed responses at constant switching frequencies.

Keywords: photovoltaic (PV) array, direct torque control (DTC), constant switching frequency, induction motor, maximum power point tracking (MPPT)

Procedia PDF Downloads 482
14841 An Approach For Evolving a Relaible Low Power Ultra Wide Band Transmitter with Capacitve Sensing

Authors: N.Revathy, C.Gomathi

Abstract:

This work aims for a tunable capacitor as a sensor which can vary the control voltage of a voltage control oscillator in a ultra wide band (UWB) transmitter. In this paper power consumption is concentrated. The reason for choosing a capacitive sensing is it give slow temperature drift, high sensitivity and robustness. Previous works report a resistive sensing in a voltage control oscillator (VCO) not aiming at power consumption. But this work aims for power consumption of a capacitive sensing in ultra wide band transmitter. The ultra wide band transmitter to be used is a direct modulation of pulses. The VCO which is the heart of pulse generator of UWB transmitter works on the principle of voltage to frequency conversion. The VCO has and odd number of inverter stages which works on the control voltage input this input is now from a variable capacitor and the buffer stages is reduced from the previous work to maintain the oscillating frequency. The VCO is also aimed to consume low power. Then the concentration in choosing a variable capacitor is aimed. A compact model of a capacitor with the transient characteristics is to be designed with a movable dielectric and multi metal membranes. Previous modeling of the capacitor transient characteristics is with a movable membrane and a fixed membrane. This work aims at a membrane with a wide tuning suitable for ultra wide band transmitter.This is used in this work because a capacitive in a ultra wide transmitter need to be tuned in such a way that all satisfies FCC regulations.

Keywords: capacitive sensing, ultra wide band transmitter, voltage control oscillator, FCC regulation

Procedia PDF Downloads 391
14840 Vibration Absorption Strategy for Multi-Frequency Excitation

Authors: Der Chyan Lin

Abstract:

Since the early introduction by Ormondroyd and Den Hartog, vibration absorber (VA) has become one of the most commonly used vibration mitigation strategies. The strategy is most effective for a primary plant subjected to a single frequency excitation. For continuous systems, notable advances in vibration absorption in the multi-frequency system were made. However, the efficacy of the VA strategy for systems under multi-frequency excitation is not well understood. For example, for an N degrees-of-freedom (DOF) primary-absorber system, there are N 'peak' frequencies of large amplitude vibration per every new excitation frequency. In general, the usable range for vibration absorption can be greatly reduced as a result. Frequency modulated harmonic excitation is a commonly seen multi-frequency excitation example: f(t) = cos(ϖ(t)t) where ϖ(t)=ω(1+α sin⁡(δt)). It is known that f(t) has a series expansion given by the Bessel function of the first kind, which implies an infinity of forcing frequencies in the frequency modulated harmonic excitation. For an SDOF system of natural frequency ωₙ subjected to f(t), it can be shown that amplitude peaks emerge at ω₍ₚ,ₖ₎=(ωₙ ± 2kδ)/(α ∓ 1),k∈Z; i.e., there is an infinity of resonant frequencies ω₍ₚ,ₖ₎, k∈Z, making the use of VA strategy ineffective. In this work, we propose an absorber frequency placement strategy for SDOF vibration systems subjected to frequency-modulated excitation. An SDOF linear mass-spring system coupled to lateral absorber systems is used to demonstrate the ideas. Although the mechanical components are linear, the governing equations for the coupled system are nonlinear. We show using N identical absorbers, for N ≫ 1, that (a) there is a cluster of N+1 natural frequencies around every natural absorber frequency, and (b) the absorber frequencies can be moved away from the plant's resonance frequency (ω₀) as N increases. Moreover, we also show the bandwidth of the VA performance increases with N. The derivations of the clustering and bandwidth widening effect will be given, and the superiority of the proposed strategy will be demonstrated via numerical experiments.

Keywords: Bessel function, bandwidth, frequency modulated excitation, vibration absorber

Procedia PDF Downloads 155
14839 Power Angle Control Strategy of Virtual Synchronous Machine: A Novel Approach to Control Virtual Synchronous Machine

Authors: Shishir Lamichhane, Saurav Dulal, Bibek Gautam, Madan Thapa Magar, Indraman Tamrakar

Abstract:

Renewable energies such as wind turbines and solar photovoltaic have gained significance as a result of global environmental pollution and energy crises. These sources of energy are converted into electrical energy and delivered to end-users through the utility system. As a result of the widespread use of power electronics-based grid-interfacing technologies to accommodate renewable sources of energy, the prevalence of converters has expanded as well. As a result, the power system's rotating inertia is decreasing, endangering the utility grid's stability. The use of Virtual Synchronous Machine (VSM) technology has been proposed to overcome the grid stability problem due to low rotating inertia. The grid-connected inverter used in VSM can be controlled to emulate inertia, which replicates the external features of a synchronous generator. As a result, the rotating inertia is increased to support the power system's stability. A power angle control strategy is proposed in this paper and its model is simulated in MATLAB/Simulink to study the effects of parameter disturbances on the active power and frequency for a VSM. The system consists of a synchronous generator, which is modeled in such a way that the frequency drops to an unacceptable region during transient conditions due to a lack of inertia when VSM is not used. Then, the suggested model incorporating VSM emulates rotating inertia, injecting a controllable amount of energy into the grid during frequency transients to enhance transient stability.

Keywords: damping constant, inertia–constant, ROCOF, transient stability, distributed sources

Procedia PDF Downloads 207
14838 Knowledge regarding Sexual and Reproductive Health among Adolescents in Higher Secondary School

Authors: Kopila Shrestha

Abstract:

Adolescent sexual reproductive health is one of the most important issues in the world. Reproductive ability is taking place at an earlier age and adolescents are indulging in risk taking behaviors day by day. A descriptive cross-sectional study was conducted in Kathmandu valley to assess the knowledge regarding sexual and reproductive health among adolescent. Total of 200 respondents were selected through non-probability convenient sampling technique. Self-administered written questionnaires using semi-structured questions were used. The collected data were analyzed by using descriptive statistics such as frequency, percentage, mean, standard deviation and inferential statistics such as Chi-square test. The findings revealed that most of the respondents had adequate knowledge regarding transmission and protection of HIV/AIDs and STIs but still some respondents had a misconception regarding it. Few respondents had knowledge regarding legal age for marriage and the minimum age for first child bearing. The statistical analysis revealed that the total mean knowledge score with standard deviation was 45.02±8.674. Nearly half of the respondents (49.5%) had a moderate level of knowledge, followed by an inadequate level of knowledge 29.5% and adequate level of knowledge 21.0% regarding sexual and reproductive health. There was significant association of level of knowledge with area of residence (p-value .002) but no association with age (p-value .067), sex (p-value .999), religion (p-value .082) and ethnicity (p-value .114). Nearly half of the participants possess some knowledge about sexual and reproductive health but still effective educational intervention is required in higher secondary school to encourage more sensible and healthy behaviour.

Keywords: adolescents, higher secondary school, knowledge, sexual and reproductive health

Procedia PDF Downloads 283
14837 Evaluation of the Irritation Potential of Three Topical Formulations of Minoxidil 5% + Finasteride 0.1% Using Patch Test

Authors: Joshi Rajiv, Shah Priyank, Thavkar Amit, Rohira Poonam, Mehta Suyog

Abstract:

Topical formulation containing minoxidil and finasteride helps hair growth in the treatment of male androgenetic alopecia. The objective of this study is to compare the irritation potential of three conventional formulations of minoxidil 5% + finasteride 0.1% topical solution of in human patch test. The study was a single centre, double blind, non-randomized controlled study in 53 healthy adult Indian subjects. Occlusive patch test for 24 hours was performed with three formulations of minoxidil 5% + finasteride 0.1% topical solution. Products tested included aqueous based minoxidil 5% + finasteride 0.1% (AnasureTM-F, Sun Pharma, India – Brand A), lipid based minoxidil 5% + finasteride 0.1% (Brand B) and aqueous based minoxidil 5% + finasteride 0.1% (Brand C). Isotonic saline 0.9% and 1% w/w sodium lauryl sulphate were included as negative control and positive control respectively. Patches were applied and removed after 24 hours. The skin reaction was assessed and clinically scored 24 hours after the removal of the patches under constant artificial daylight source using the Draize scale (0-4 points scale for erythema/dryness//wrinkles and for oedema). Follow-up was scheduled after one week to confirm recovery for any reaction. A combined mean score up to 2.0/8.0 indicates a product is “non-irritant” and a score between 2.0/8.0 and 4.0/8.0 indicates “mildly irritant” and a score above 4.0/8.0 indicates “irritant”. The procedure of the patch test followed the principles outlined by the Bureau of Indian Standards (BIS) (IS 4011:2018; Methods of Test for safety evaluation of Cosmetics-3rd revision). Fifty three subjects with mean age 31.9 years (25 males and 28 females) participated in the study. The combined mean score ± standard deviation were: 0.06 ± 0.23 (Brand A), 0.81 ± 0.59 (Brand B), 0.38 ± 0.49 (Brand C), 2.92 ± 0.47 (positive control) and 0.0 ± 0.0 (Negative control). This means the score of Brand A (Sun Pharma product) was significantly lower than that of Brand B (p=0.001) and that of Brand C (p=0.001). The combined mean erythema score ± standard deviation were: 0.06 ± 0.23 (Brand A), 0.81 ± 0.59 (Brand B), 0.38 ± 0.49 (Brand C), 2.09 ± 0.4 (Positive control) and 0.0 ± 0.0 (Negative control). The mean erythema score of Brand A was significantly lower than Brand B (p=0.001) and that of Brand C (p=0.001). Any reaction observed at 24hours after patch removal subsided in a week. All the three topical formulations of minoxidil 5% + finasteride 0.1% were non-irritant. Brand A of minoxidil 5% + finasteride 0.1% (Sun Pharma) was found to be the least irritant than Brand B and Brand C based on the combined mean score and mean erythema score in the human patch test as per the BIS, IS 4011:2018

Keywords: erythema, finasteride, irritation, minoxidil, patch test

Procedia PDF Downloads 84
14836 Dynamics Characterizations of Dielectric Electro- Active Polymer Pull Actuator for Vibration Control

Authors: A. M. Wahab, E. Rustighi

Abstract:

Elastomeric dielectric material has recently become a new alternative for actuator technology. The characteristics of dielectric elastomers placed between two electrodes to withstand large strain when electrodes are charged has attracted the attention of many researcher to study this material for actuator technology. Thus, in the past few years Danfoss Ventures A/S has established their own dielectric electro-active polymer (DEAP), which was called PolyPower. The main objective of this work was to investigate the dynamic characteristics for vibration control of a PolyPower actuator folded in ‘pull’ configuration. A range of experiments was carried out on the folded actuator including passive (without electrical load) and active (with electrical load) testing. For both categories static and dynamic testing have been done to determine the behavior of folded DEAP actuator. Voltage-Strain experiments show that the DEAP folded actuator is a non-linear system. It is also shown that the voltage supplied has no effect on the natural frequency. Finally, varying AC voltage with different amplitude and frequency shows the parameters that influence the performance of DEAP folded actuator. As a result, the actuator performance dominated by the frequency dependence of the elastic response and was less influenced by dielectric properties.

Keywords: dielectric electro-active polymer, pull actuator, static, dynamic, electromechanical

Procedia PDF Downloads 250
14835 Mixed Frequency Excitation of an Electrostatically Actuated Resonator

Authors: Abdallah H. Ramini, Alwathiqbellah I. Ibrahim, Mohammad I. Younis

Abstract:

We investigate experimentally and theoretically the dynamics of a capacitive resonator under mixed frequency excitation of two AC harmonic signals. The resonator is composed of a proof mass suspended by two cantilever beams. Experimental measurements are conducted using a laser Doppler Vibrometer to reveal the interesting dynamics of the system when subjected to two-source excitation. A nonlinear single-degree-of-freedom model is used for the theoretical investigation. The results reveal combination resonances of additive and subtractive type, which are shown to be promising to increase the bandwidth of the resonator near primary resonance frequency. Our results also demonstrate the ability to shift the combination resonances to much lower or much higher frequency ranges. We also demonstrate the dynamic pull-in instability under mixed frequency excitation.

Keywords: electrostatically actuated resonator, multi-frequency excitation, nonlinear dynamics, AC harmonic signals

Procedia PDF Downloads 622
14834 Deviations and Defects of the Sub-Task’s Requirements in Construction Projects

Authors: Abdullah Almusharraf, Andrew Whyte

Abstract:

The sub-task pattern in terms of the deviations and defects should be identified and understand in order to improve the quality practices in construction projects. Therefore, the sub-task susceptibility to exposure to deviations and defects have been evaluated and classified via six classifications that have proposed in this study. 34 case studies on specific sub-task (from compression member in construction concrete structure) have been collected from seven construction projects in order to examined study’s classifications. The study revealed that the sub-task has high sensitive to deviation where (91%) of the cases recorded as deviations, however, only (19%) of cases recorded as defects. Another findings were that the actual work during the execution process has high source of deviation for this sub-task (74%) while only (26%) of the deviation source was due to both design documentations with the actual work. These findings significantly imply that it could be used the study’s classifications to determine the pattern of each sub-task and develop the proactive actions to overcome issues of the sub-task deviations and defects.

Keywords: sub-tasks, deviations, defects, quality, construction projects

Procedia PDF Downloads 444
14833 Analysis of Diabetes Patients Using Pearson, Cost Optimization, Control Chart Methods

Authors: Devatha Kalyan Kumar, R. Poovarasan

Abstract:

In this paper, we have taken certain important factors and health parameters of diabetes patients especially among children by birth (pediatric congenital) where using the above three metrics methods we are going to assess the importance of each attributes in the dataset and thereby determining the most highly responsible and co-related attribute causing diabetics among young patients. We use cost optimization, control chart and Spearmen methodologies for the real-time application of finding the data efficiency in this diabetes dataset. The Spearmen methodology is the correlation methodologies used in software development process to identify the complexity between the various modules of the software. Identifying the complexity is important because if the complexity is higher, then there is a higher chance of occurrence of the risk in the software. With the use of control; chart mean, variance and standard deviation of data are calculated. With the use of Cost optimization model, we find to optimize the variables. Hence we choose the Spearmen, control chart and cost optimization methods to assess the data efficiency in diabetes datasets.

Keywords: correlation, congenital diabetics, linear relationship, monotonic function, ranking samples, pediatric

Procedia PDF Downloads 256
14832 A Deterministic Large Deviation Model Based on Complex N-Body Systems

Authors: David C. Ni

Abstract:

In the previous efforts, we constructed N-Body Systems by an extended Blaschke product (EBP), which represents a non-temporal and nonlinear extension of Lorentz transformation. In this construction, we rely only on two parameters, nonlinear degree, and relative momentum to characterize the systems. We further explored root computation via iteration with an algorithm extended from Jenkins-Traub method. The solution sets demonstrate a form of σ+ i [-t, t], where σ and t are the real numbers, and the [-t, t] shows various canonical distributions. In this paper, we correlate the convergent sets in the original domain with solution sets, which demonstrating large-deviation distributions in the codomain. We proceed to compare our approach with the formula or principles, such as Donsker-Varadhan and Wentzell-Freidlin theories. The deterministic model based on this construction allows us to explore applications in the areas of finance and statistical mechanics.

Keywords: nonlinear Lorentz transformation, Blaschke equation, iteration solutions, root computation, large deviation distribution, deterministic model

Procedia PDF Downloads 393
14831 A Robust Frequency Offset Estimator for Orthogonal Frequency Division Multiplexing

Authors: Keunhong Chae, Seokho Yoon

Abstract:

We address the integer frequency offset (IFO) estimation under the influence of the timing offset (TO) in orthogonal frequency division multiplexing (OFDM) systems. Incorporating the IFO and TO into the symbol set used to represent the received OFDM symbol, we investigate the influence of the TO on the IFO, and then, propose a combining method between two consecutive OFDM correlations, reducing the influence. The proposed scheme has almost the same complexity as that of the conventional schemes, whereas it does not need the TO knowledge contrary to the conventional schemes. From numerical results it is confirmed that the proposed scheme is insensitive to the TO, consequently, yielding an improvement of the IFO estimation performance over the conventional schemes when the TO exists.

Keywords: estimation, integer frequency offset, OFDM, timing offset

Procedia PDF Downloads 474
14830 Investigation of the Unbiased Characteristic of Doppler Frequency to Different Antenna Array Geometries

Authors: Somayeh Komeylian

Abstract:

Array signal processing techniques have been recently developing in a variety application of the performance enhancement of receivers by refraining the power of jamming and interference signals. In this scenario, biases induced to the antenna array receiver degrade significantly the accurate estimation of the carrier phase. Owing to the integration of frequency becomes the carrier phase, we have obtained the unbiased doppler frequency for the high precision estimation of carrier phase. The unbiased characteristic of Doppler frequency to the power jamming and the other interference signals allows achieving the highly accurate estimation of phase carrier. In this study, we have rigorously investigated the unbiased characteristic of Doppler frequency to the variation of the antenna array geometries. The simulation results have efficiently verified that the Doppler frequency remains also unbiased and accurate to the variation of antenna array geometries.

Keywords: array signal processing, unbiased doppler frequency, GNSS, carrier phase, and slowly fluctuating point target

Procedia PDF Downloads 159
14829 Multi-Band Frequency Conversion Scheme with Multi-Phase Shift Based on Optical Frequency Comb

Authors: Tao Lin, Shanghong Zhao, Yufu Yin, Zihang Zhu, Wei Jiang, Xuan Li, Qiurong Zheng

Abstract:

A simple operated, stable and compact multi-band frequency conversion and multi-phase shift is proposed to satisfy the demands of multi-band communication and radar phase array system. The dual polarization quadrature phase shift keying (DP-QPSK) modulator is employed to support the LO sideband and the optical frequency comb simultaneously. Meanwhile, the fiber is also used to introduce different phase shifts to different sidebands. The simulation result shows that by controlling the DC bias voltages and a C band microwave signal with frequency of 4.5 GHz can be simultaneously converted into other signals that cover from C band to K band with multiple phases. It also verifies that the multi-band and multi-phase frequency conversion system can be stably performed based on current manufacturing art and can well cope with the DC drifting. It should be noted that the phase shift of the converted signal also partly depends of the length of the optical fiber.

Keywords: microwave photonics, multi-band frequency conversion, multi-phase shift, conversion efficiency

Procedia PDF Downloads 254
14828 Cyber Security Enhancement via Software Defined Pseudo-Random Private IP Address Hopping

Authors: Andre Slonopas, Zona Kostic, Warren Thompson

Abstract:

Obfuscation is one of the most useful tools to prevent network compromise. Previous research focused on the obfuscation of the network communications between external-facing edge devices. This work proposes the use of two edge devices, external and internal facing, which communicate via private IPv4 addresses in a software-defined pseudo-random IP hopping. This methodology does not require additional IP addresses and/or resources to implement. Statistical analyses demonstrate that the hopping surface must be at least 1e3 IP addresses in size with a broad standard deviation to minimize the possibility of coincidence of monitored and communication IPs. The probability of breaking the hopping algorithm requires a collection of at least 1e6 samples, which for large hopping surfaces will take years to collect. The probability of dropped packets is controlled via memory buffers and the frequency of hops and can be reduced to levels acceptable for video streaming. This methodology provides an impenetrable layer of security ideal for information and supervisory control and data acquisition systems.

Keywords: moving target defense, cybersecurity, network security, hopping randomization, software defined network, network security theory

Procedia PDF Downloads 185
14827 CFD Studies on Forced Convection Nanofluid Flow Inside a Circular Conduit

Authors: M. Khalid, W. Rashmi, L. L. Kwan

Abstract:

This work provides an overview on the experimental and numerical simulations of various nanofluids and their flow and heat transfer behavior. It was further extended to study the effect of nanoparticle concentration, fluid flow rates and thermo-physical properties on the heat transfer enhancement of Al2O3/water nanofluid in a turbulent flow circular conduit using ANSYS FLUENT™ 14.0. Single-phase approximation (homogeneous model) and two-phase (mixture and Eulerian) models were used to simulate the nanofluid flow behavior in the 3-D horizontal pipe. The numerical results were further validated with experimental correlations reported in the literature. It was found that heat transfer of nanofluids increases with increasing particle volume concentration and Reynolds number, respectively. Results showed good agreement (~9% deviation) with the experimental correlations, especially for a single-phase model with constant properties. Among two-phase models, mixture model (~14% deviation) showed better prediction compared to Eulerian-dispersed model (~18% deviation) when temperature independent properties were used. Non-drag forces were also employed in the Eulerian two-phase model. However, the two-phase mixture model with temperature dependent nanofluid properties gave slightly closer agreement (~12% deviation).

Keywords: nanofluid, CFD, heat transfer, forced convection, circular conduit

Procedia PDF Downloads 523
14826 DNA Damage and Apoptosis Induced in Drosophila melanogaster Exposed to Different Duration of 2400 MHz Radio Frequency-Electromagnetic Fields Radiation

Authors: Neha Singh, Anuj Ranjan, Tanu Jindal

Abstract:

Over the last decade, the exponential growth of mobile communication has been accompanied by a parallel increase in density of electromagnetic fields (EMF). The continued expansion of mobile phone usage raises important questions as EMF, especially radio frequency (RF), have long been suspected of having biological effects. In the present experiments, we studied the effects of RF-EMF on cell death (apoptosis) and DNA damage of a well- tested biological model, Drosophila melanogaster exposed to 2400 MHz frequency for different time duration i.e. 2 hrs, 4 hrs, 6 hrs,8 hrs, 10 hrs, and 12 hrs each day for five continuous days in ambient temperature and humidity conditions inside an exposure chamber. The flies were grouped into control, sham-exposed, and exposed with 100 flies in each group. In this study, well-known techniques like Comet Assay and TUNEL (Terminal deoxynucleotide transferase dUTP Nick End Labeling) Assay were used to detect DNA damage and for apoptosis studies, respectively. Experiments results showed DNA damage in the brain cells of Drosophila which increases as the duration of exposure increases when observed under the observed when we compared results of control, sham-exposed, and exposed group which indicates that EMF radiation-induced stress in the organism that leads to DNA damage and cell death. The process of apoptosis and mutation follows similar pathway for all eukaryotic cells; therefore, studying apoptosis and genotoxicity in Drosophila makes similar relevance for human beings as well.

Keywords: cell death, apoptosis, Comet Assay, DNA damage, Drosophila, electromagnetic fields, EMF, radio frequency, RF, TUNEL assay

Procedia PDF Downloads 169
14825 Apolipoprotein A1 -75 G to a Substitution and Its Relationship with Serum ApoA1 Levels among Indian Punjabi Population

Authors: Savjot Kaur, Mridula Mahajan, AJS Bhanwer, Santokh Singh, Kawaljit Matharoo

Abstract:

Background: Disorders of lipid metabolism and genetic predisposition are CAD risk factors. ApoA1 is the apolipoprotein component of anti-atherogenic high density lipoprotein (HDL) particles. The protective action of HDL and ApoA1 is attributed to their central role in reverse cholesterol transport (RCT). Aim: This study was aimed at identifying sequence variations in ApoA1 (-75G>A) and its association with serum ApoA1 levels. Methods: A total of 300 CAD patients and 300 Normal individuals (controls) were analyzed. PCR-RFLP method was used to determine the DNA polymorphism in the ApoA1 gene, PCR products digested with restriction enzyme MspI, followed by Agarose Gel Electrophoresis. Serum apolipoprotein A1 concentration was estimated with immunoturbidimetric method. Results: Deviation from Hardy- Weinberg Equilibrium (HWE) was observed for this gene variant. The A- allele frequency was higher among Coronary Artery disease patients (53.8) compared to controls (45.5), p= 0.004, O.R= 1.38(1.11-1.75). Under recessive model analysis (AA vs. GG+GA) AA genotype of ApoA1 G>A substitution conferred ~1 fold increased risk towards CAD susceptibility (p= 0.002, OR= 1.72(1.2-2.43). With serum ApoA1 levels < 107 A allele frequency was higher among CAD cases (50) as compared to controls (43.4) [p=0.23, OR= 1.2(0.84-2)] and there was zero % occurrence of A allele frequency in individuals with ApoA1 levels > 177. Conclusion: Serum ApoA1 levels were associated with ApoA1 promoter region variation and influence CAD risk. The individuals with the APOA1 -75 A allele confer excess hazard of developing CAD as a result of its effect on low serum concentrations of ApoA1.

Keywords: apolipoprotein A1 (G>A) gene polymorphism, coronary artery disease (CAD), reverse cholesterol transport (RCT)

Procedia PDF Downloads 315
14824 Design of a Phemt Buffer Amplifier in Mm-Wave Band around 60 GHz

Authors: Maryam Abata, Moulhime El Bekkali, Said Mazer, Catherine Algani, Mahmoud Mehdi

Abstract:

One major problem of most electronic systems operating in the millimeter wave band is the signal generation with a high purity and a stable carrier frequency. This problem is overcome by using the combination of a signal with a low frequency local oscillator (LO) and several stages of frequency multipliers. The use of these frequency multipliers to create millimeter-wave signals is an attractive alternative to direct generation signal. Therefore, the isolation problem of the local oscillator from the other stages is always present, which leads to have various mechanisms that can disturb the oscillator performance, thus a buffer amplifier is often included in oscillator outputs. In this paper, we present the study and design of a buffer amplifier in the mm-wave band using a 0.15μm pHEMT from UMS foundry. This amplifier will be used as a part of a frequency quadrupler at 60 GHz.

Keywords: Mm-wave band, local oscillator, frequency quadrupler, buffer amplifier

Procedia PDF Downloads 544
14823 Synthetic Optimizing Control of Wind-Wave Hybrid Energy Conversion System

Authors: Lei Xue, Liye Zhao, Jundong Wang, Yu Xue

Abstract:

A hybrid energy conversion system composed of a floating offshore wind turbine (FOWT) and wave energy converters (WECs) may possibly reduce the levelized cost of energy, improving the platform dynamics and increasing the capacity to harvest energy. This paper investigates the aerodynamic performance and dynamic responses of the combined semi-submersible FOWT and point-absorber WECs in frequency and time domains using synthetic optimizing control under turbulent wind and irregular wave conditions. Individual pitch control is applied to the FOWT part, while spring–damping control is used on the WECs part, as well as the synergistic control effect of both are studied. The effect of the above control optimization is analyzed under several typical working conditions, such as below-rated wind speed, rated wind speed, and above-rated wind speed by OpenFAST and WEC-Sim software. Particularly, the wind-wave misalignment is also comparatively investigated, which has demonstrated the importance of applying proper integrated optimal control in this hybrid energy system. More specifically, the combination of individual pitch control and spring–damping control is able to mitigate the platform pitch motion and improve output power. However, the increase in blade root load needs to be considered which needs further investigations in the future.

Keywords: floating offshore wind turbine, wave energy converters, control optimization, individual pitch control, dynamic response

Procedia PDF Downloads 53
14822 A New IFO Estimation Scheme for Orthogonal Frequency Division Multiplexing Systems

Authors: Keunhong Chae, Seokho Yoon

Abstract:

We address a new integer frequency offset (IFO) estimation scheme with an aid of a pilot for orthogonal frequency division multiplexing systems. After correlating each continual pilot with a predetermined scattered pilot, the correlation value is again correlated to alleviate the influence of the timing offset. From numerical results, it is demonstrated that the influence of the timing offset on the IFO estimation is significantly decreased.

Keywords: estimation, integer frequency offset, OFDM, timing offset

Procedia PDF Downloads 568
14821 Dynamics Characterizations of Dielectric Electro- Active Polymer Pull Actuator for Vibration Control


Authors: Abdul Malek Abdul Wahab, Emiliano Rustighi

Abstract:

The elastomeric dielectric material has become a new alternative for actuator technology recently. The characteristic of dielectric elastomer that induces significant strain by applying voltage attracts the attention of many researchers to study this material in actuator technology. Thus, for a couple of years, Danfoss Ventures A/S has established their dielectric electro-active polymer (DEAP), which called Polypower. The main objective of this work was to investigate the characterization of PolyPower folded actuator as a ‘pull’ actuator for vibration control. A range of experiment was carried out on folded actuator including passive (without electrical stimulate) and active (with electrical stimulate) testing. For both categories static and dynamic testing have been done to determine the behavior of folded DEAP actuator. Voltage-Strain experiment determines that DEAP folded actuator is the non-linear system. The voltage supplied has no effect on the natural frequency which shows by ongoing dynamic testing. Finally, varies AC voltage with different amplitude and frequency has been provided to DEAP folded actuator. This experiment shows the parameter that influences the performance of DEAP folded actuator. As a result, the actuator performance dominated by the frequency dependence of the elastic response and was less influenced by dielectric properties.

Keywords: elastomeric dielectric, dielectric electro-active polymer, folded actuator, voltage-strain

Procedia PDF Downloads 318
14820 Comparative Analysis of Control Techniques Based Sliding Mode for Transient Stability Assessment for Synchronous Multicellular Converter

Authors: Rihab Hamdi, Amel Hadri Hamida, Fatiha Khelili, Sakina Zerouali, Ouafae Bennis

Abstract:

This paper features a comparative study performance of sliding mode controller (SMC) for closed-loop voltage control of direct current to direct current (DC-DC) three-cells buck converter connected in parallel, operating in continuous conduction mode (CCM), based on pulse-width modulation (PWM) with SMC based on hysteresis modulation (HM) where an adaptive feedforward technique is adopted. On one hand, for the PWM-based SM, the approach is to incorporate a fixed-frequency PWM scheme which is effectively a variant of SM control. On the other hand, for the HM-based SM, oncoming an adaptive feedforward control that makes the hysteresis band variable in the hysteresis modulator of the SM controller in the aim to restrict the switching frequency variation in the case of any change of the line input voltage or output load variation are introduced. The results obtained under load change, input change and reference change clearly demonstrates a similar dynamic response of both proposed techniques, their effectiveness is fast and smooth tracking of the desired output voltage. The PWM-based SM technique has greatly improved the dynamic behavior with a bit advantageous compared to the HM-based SM technique, as well as provide stability in any operating conditions. Simulation studies in MATLAB/Simulink environment have been performed to verify the concept.

Keywords: DC-DC converter, hysteresis modulation, parallel multi-cells converter, pulse-width modulation, robustness, sliding mode control

Procedia PDF Downloads 167
14819 Fractional-Order PI Controller Tuning Rules for Cascade Control System

Authors: Truong Nguyen Luan Vu, Le Hieu Giang, Le Linh

Abstract:

The fractional–order proportional integral (FOPI) controller tuning rules based on the fractional calculus for the cascade control system are systematically proposed in this paper. Accordingly, the ideal controller is obtained by using internal model control (IMC) approach for both the inner and outer loops, which gives the desired closed-loop responses. On the basis of the fractional calculus, the analytical tuning rules of FOPI controller for the inner loop can be established in the frequency domain. Besides, the outer loop is tuned by using any integer PI/PID controller tuning rules in the literature. The simulation study is considered for the stable process model and the results demonstrate the simplicity, flexibility, and effectiveness of the proposed method for the cascade control system in compared with the other methods.

Keywords: Bode’s ideal transfer function, fractional calculus, fractional–order proportional integral (FOPI) controller, cascade control system

Procedia PDF Downloads 377
14818 The Behavior and Satisfaction of Tourists Affecting the Sustainable Tourism at the Amphawa Floating Market in Samut Songkhram Province

Authors: Chanpen Meenakorn

Abstract:

This research aims to study; (1) behavior of the tourists affecting the satisfaction level of tourism at the Amphawa floating market in Samut Songkhram province, (2) to study the satisfaction level of tourism at the Amphawa floating market. The research method will use quantitative research; data was collected by questionnaires distributed to the tourist who visits the Amphawa floating market for 480 samples. Data was analyzed by SPSS software to process descriptive statistic including frequency, percentage, mean, standard deviation and inferential statistic is t-test, F-test, and chi-square. The results showed that the behavior of tourists had known tourist attractions in the province comes from the mouth of relatives and friends suggested that he come here before and the reasons to visit is to want to pay homage to the various temples for the frequency to visit travel an average of 2-4 times and  the satisfaction of the tourists in the province found that the satisfaction level of tourists in the province at the significant level of the place, convenient  and services have a high level of satisfaction.

Keywords: amphawa floating market behavior of the tourists, satisfaction level, sustainable tourism, Samut Songkhram province

Procedia PDF Downloads 366
14817 Evaluation of the Irritation Potential of Three Topical Formulations of Minoxidil 2% Using Patch Test

Authors: Sule Pallavi, Shah Priyank, Thavkar Amit, Rohira Poonam, Mehta Suyog

Abstract:

Introduction: Minoxidil has been used topically for a long time to assist hair growth in the management of male androgenetic alopecia. The aim of this study was a comparative assessment of the irritation potential of three commercial formulations of minoxidil 2% topical solution in a human patch test. Methodology: The study was a non-randomized, double-blind, controlled, single-center study of 56 healthy adult Indian subjects. A 24-hour occlusive patch test was conducted with three formulations of minoxidil 2% topical solution. Products tested were aqueous-based minoxidil 2% (AnasureTM 2%, Sun Pharma, India – Brand A), alcohol-based minoxidil 2% (Brand B) and aqueous-based minoxidil 2% (Brand C). Isotonic saline 0.9% and 1% w/w sodium lauryl sulphate as a negative and positive control, respectively, were included. Patches were applied on the back, followed by removal after 24 hours. The Draize scale (0-4 points scale for erythema/dryness/wrinkles and for oedema) was used to evaluate and clinically score the skin reaction under constant artificial daylight 24 hours after the removal of the patches. The patch test was based on the principles outlined by Bureau of Indian Standards (BIS) (IS 4011:2018; Methods of Test for safety evaluation of Cosmetics-3rd revision). A mean combined score up to 2.0/8.0 indicates that a product is “non-irritant,” and a score between 2.0/8.0 and 4.0/8.0 indicates “mildly irritant” and a score above 4.0/8.0 indicates “irritant”. In case of any skin reaction that was observed, a follow-up was planned after one week to confirm recovery. Results: The 56 subjects who participated in the study had a mean age of 28.7 years (28 males and 28 females). The combined mean score ± standard deviation was: 0.09 ± 0.29 (Brand A), 0.29± 0.53 (Brand B), 0.30 ± 0.46 (Brand C), 3.25 ± 0.77 (positive control) and 0.02 ± 0.13 (negative control). This mean score of Brand A (Sun Pharma) was significantly lower than that of Brand B (p=0.016) and that of Brand C (p=0.004). The mean erythema score ± standard deviation was: 0.09 ± 0.29 (Brand A), 0.27 ± 0.49 (Brand B), 0.30 ± 0.46 (Brand C), 2.5 ± 0.66 (positive control) and 0.02 ± 0.13 (negative control). The mean erythema score of Brand A (Sun Pharma) was significantly lower than that of Brand B (p=0.019) and that of Brand C (p=0.004). Reactions that were observed 24 hours after patch removal subsided in a week’s time. Conclusion: Based on the human patch test as per the BIS, IS 4011:2018, all the three topical formulations of minoxidil 2% were found to be non-irritant. Brand A of 2% minoxidil (Sun Pharma) was found to be the least irritant than Brand B and Brand C based on the combined mean score and mean erythema score.

Keywords: erythema, irritation, minoxidil, patch test

Procedia PDF Downloads 82