Search results for: antimicrobial sensitivity
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2667

Search results for: antimicrobial sensitivity

1407 Two-Photon Ionization of Silver Clusters

Authors: V. Paployan, K. Madoyan, A. Melikyan, H. Minassian

Abstract:

Resonant two-photon ionization (TPI) is a valuable technique for the study of clusters due to its ultrahigh sensitivity. The comparison of the observed TPI spectra with results of calculations allows to deduce important information on the shape, rotational and vibrational temperatures of the clusters with high accuracy. In this communication we calculate the TPI cross-section for pump-probe scheme in Ag neutral cluster. The pump photon energy is chosen to be close to the surface plasmon (SP) energy of cluster in dielectric media. Since the interband transition energy in Ag exceeds the SP resonance energy, the main contribution into the TPI comes from the latter. The calculations are performed by separating the coordinates of electrons corresponding to the collective oscillations and the individual motion that allows to take into account the resonance contribution of excited SP oscillations. It is shown that the ionization cross section increases by two orders of magnitude if the energy of the pump photon matches the surface plasmon energy in the cluster.

Keywords: resonance enhancement, silver clusters, surface plasmon, two-photon ionization

Procedia PDF Downloads 427
1406 Examining Gender Bias in the Sport Concussion Assessment Tool 3 (SCAT3): A Differential Item Functioning Analysis in NCAA Sports

Authors: Rachel M. Edelstein, John D. Van Horn, Karen M. Schmidt, Sydney N. Cushing

Abstract:

As a consequence of sports-related concussions, female athletes have been documented as reporting more symptoms than their male counterparts, in addition to incurring longer periods of recovery. However, the role of sex and its potential influence on symptom reporting and recovery outcomes in concussion management has not been completely explored. The present aims to investigate the relationship between female concussion symptom severity and the presence of assessment bias. The Sport Concussion Assessment Tool 3 (SCAT3), collected by the NCAA and DoD CARE Consortium, was quantified at five different time points post-concussion. N= 1,258 NCAA athletes, n= 473 female (soccer, rugby, lacrosse, ice hockey) and n=785 male athletes (football, rugby, lacrosse, ice hockey). A polytomous Item Response Theory (IRT) Graded Response Model (GRM) was used to assess the relationship between sex and symptom reporting. Differential Item Functioning (DIF) and Differential Group Functioning (DGF) were used to examine potential group-level bias. Interactions for DIF were utilized to explore the impact of sex on symptom reporting among NCAA male and female athletes throughout and after their concussion recovery. DIF was significantly detected after B-H corrections displayed in limited items; however, one symptom, “Pressure in Head” (-0.29, p=0.04 vs -0.20, p =0.04), was statistically significant at both < 6 hours and 24-48 hours. Thus, implies that at < 6 hours, males were 29% less likely to indicate “Pressure in the Head” compared to female athletes and 20% less likely at 24-48 hours. Overall, the DGF suggested significant group differences, suggesting that male athletes might be at a higher risk for returning to play prematurely (logits = -0.38, p < 0.001). However, after analyzing the SCAT 3, a clinically relevant trend was discovered. Twelve out of the twenty-two symptoms suggest higher difficulty in female athletes within three or more of the five-time points. These symptoms include Balance Problems, Blurry Vision, Confusion, Dizziness, Don’t Feel Right, Feel in Fog, Feel Slow Down, Low Energy, Neck Pain, Sensitivity to Light, Sensitivity to Noise, Trouble Falling Asleep. Despite a lack of statistical significance, this tendency is contrary to current literature stating that males may be unclear on symptoms, but females may be more honest in reporting symptoms. Further research, which includes possible modifying socioecological factors, is needed to determine whether females may consistently experience more symptoms and require longer recovery times or if, parsimoniously, males tend to present their symptoms and readiness for play differently than females. Such research will help to improve the validity of current assumptions concerning male as compared to female head injuries and optimize individualized treatments for sports-related head injuries.

Keywords: female athlete, sports-related concussion, item response theory, concussion assessment

Procedia PDF Downloads 77
1405 Load Relaxation Behavior of Ferritic Stainless Steels

Authors: Seok Hong Min, Tae Kwon Ha

Abstract:

High-temperature deformation behavior of ferritic stainless steels such as STS 409L, STS 430J1L, and STS 429EM has been investigated in this study. Specimens with fully annealed microstructure were obtained by heat treatment. A series of load relaxation tests has been conducted on these samples at temperatures ranging from 200 to 900oC to construct flow curves in the strain rate range from 10-6 s-1 to 10-3 s-1. Strain hardening was not observed at high temperatures above 800oC in any stainless steels. Load relaxation behavior at the temperature was closely related with high-temperature mechanical properties such as the thermal fatigue and tensile behaviors. Load drop ratio of 436L stainless steel was much higher than that of the other steels. With increasing temperature, strength and load drop ratio of ferritic stainless steels showed entirely different trends.

Keywords: ferritic stainless steel, high temperature deformation, load relaxation, microstructure, strain rate sensitivity

Procedia PDF Downloads 335
1404 Morphological Features Fusion for Identifying INBREAST-Database Masses Using Neural Networks and Support Vector Machines

Authors: Nadia el Atlas, Mohammed el Aroussi, Mohammed Wahbi

Abstract:

In this paper a novel technique of mass characterization based on robust features-fusion is presented. The proposed method consists of mainly four stages: (a) the first phase involves segmenting the masses using edge information’s. (b) The second phase is to calculate and fuse the most relevant morphological features. (c) The last phase is the classification step which allows us to classify the images into benign and malignant masses. In this step we have implemented Support Vectors Machines (SVM) and Artificial Neural Networks (ANN), which were evaluated with the following performance criteria: confusion matrix, accuracy, sensitivity, specificity, receiver operating characteristic ROC, and error histogram. The effectiveness of this new approach was evaluated by a recently developed database: INBREAST database. The fusion of the most appropriate morphological features provided very good results. The SVM gives accuracy to within 64.3%. Whereas the ANN classifier gives better results with an accuracy of 97.5%.

Keywords: breast cancer, mammography, CAD system, features, fusion

Procedia PDF Downloads 599
1403 A Novel Method For Non-Invasive Diagnosis Of Hepatitis C Virus Using Electromagnetic Signal Detection: A Multicenter International Study

Authors: Gamal Shiha, Waleed Samir, Zahid Azam, Premashis Kar, Saeed Hamid, Shiv Sarin

Abstract:

A simple, rapid and non-invasive electromagnetic sensor (C-FAST device) was- patented; for diagnosis of HCV RNA. Aim: To test the validity of the device compared to standard HCV PCR. Subjects and Methods: The first phase was done as pilot in Egypt on 79 participants; the second phase was done in five centers: one center from Egypt, two centers from Pakistan and two centers from India (800, 92 and 113 subjects respectively). The third phase was done nationally as multicenter study on (1600) participants for ensuring its representativeness. Results: When compared to PCR technique, C-FAST device revealed sensitivity 95% to 100%, specificity 95.5% to 100%, PPV 89.5% to 100%, NPV 95% to 100% and positive likelihood ratios 21.8% to 38.5%. Conclusion: It is practical evidence that HCV nucleotides emit electromagnetic signals that can be used for its identification. As compared to PCR, C-FAST is an accurate, valid and non-invasive device.

Keywords: C-FAST- a valid and reliable device, distant cellular interaction, electromagnetic signal detection, non-invasive diagnosis of HCV

Procedia PDF Downloads 432
1402 Flux-Gate vs. Anisotropic Magneto Resistance Magnetic Sensors Characteristics in Closed-Loop Operation

Authors: Neoclis Hadjigeorgiou, Spyridon Angelopoulos, Evangelos V. Hristoforou, Paul P. Sotiriadis

Abstract:

The increasing demand for accurate and reliable magnetic measurements over the past decades has paved the way for the development of different types of magnetic sensing systems as well as of more advanced measurement techniques. Anisotropic Magneto Resistance (AMR) sensors have emerged as a promising solution for applications requiring high resolution, providing an ideal balance between performance and cost. However, certain issues of AMR sensors such as non-linear response and measurement noise are rarely discussed in the relevant literature. In this work, an analog closed loop compensation system is proposed, developed and tested as a means to eliminate the non-linearity of AMR response, reduce the 1/f noise and enhance the sensitivity of magnetic sensor. Additional performance aspects, such as cross-axis and hysteresis effects are also examined. This system was analyzed using an analytical model and a P-Spice model, considering both the sensor itself as well as the accompanying electronic circuitry. In addition, a commercial closed loop architecture Flux-Gate sensor (calibrated and certified), has been used for comparison purposes. Three different experimental setups have been constructed for the purposes of this work, each one utilized for DC magnetic field measurements, AC magnetic field measurements and Noise density measurements respectively. The DC magnetic field measurements have been conducted in laboratory environment employing a cubic Helmholtz coil setup in order to calibrate and characterize the system under consideration. A high-accuracy DC power supply has been used for providing the operating current to the Helmholtz coils. The results were recorded by a multichannel voltmeter The AC magnetic field measurements have been conducted in laboratory environment employing a cubic Helmholtz coil setup in order to examine the effective bandwidth not only of the proposed system but also for the Flux-Gate sensor. A voltage controlled current source driven by a function generator has been utilized for the Helmholtz coil excitation. The result was observed by the oscilloscope. The third experimental apparatus incorporated an AC magnetic shielding construction composed of several layers of electric steel that had been demagnetized prior to the experimental process. Each sensor was placed alone and the response was captured by the oscilloscope. The preliminary experimental results indicate that closed loop AMR response presented a maximum deviation of 0.36% with respect to the ideal linear response, while the corresponding values for the open loop AMR system and the Fluxgate sensor reached 2% and 0.01% respectively. Moreover, the noise density of the proposed close loop AMR sensor system remained almost as low as the noise density of the AMR sensor itself, yet considerably higher than that of the Flux-Gate sensor. All relevant numerical data are presented in the paper.

Keywords: AMR sensor, chopper, closed loop, electronic noise, magnetic noise, memory effects, flux-gate sensor, linearity improvement, sensitivity improvement

Procedia PDF Downloads 421
1401 Delamination of Scale in a Fe Carbon Steel Surface by Effect of Interface Roughness and Oxide Scale Thickness

Authors: J. M. Lee, W. R. Noh, C. Y. Kim, M. G. Lee

Abstract:

Delamination of oxide scale has been often discovered at the interface between Fe carbon steel and oxide scale. Among several mechanisms of this delamination behavior, the normal tensile stress to the substrate-scale interface has been described as one of the main factors. The stress distribution at the interface is also known to be affected by thermal expansion mismatch between substrate and oxide scale, creep behavior during cooling and the geometry of the interface. In this study, stress states near the interface in a Fe carbon steel with oxide scale have been investigated using FE simulations. The thermal and mechanical properties of oxide scales are indicated in literature and Fe carbon steel is measured using tensile testing machine. In particular, the normal and shear stress components developed at the interface during bending are investigated. Preliminary numerical sensitivity analyses are provided to explain the effects of the interface geometry and oxide thickness on the delamination behavior.

Keywords: oxide scale, delamination, Fe analysis, roughness, thickness, stress state

Procedia PDF Downloads 344
1400 Using Priority Order of Basic Features for Circumscribed Masses Detection in Mammograms

Authors: Minh Dong Le, Viet Dung Nguyen, Do Huu Viet, Nguyen Huu Tu

Abstract:

In this paper, we present a new method for circumscribed masses detection in mammograms. Our method is evaluated on 23 mammographic images of circumscribed masses and 20 normal mammograms from public Mini-MIAS database. The method is quite sanguine with sensitivity (SE) of 95% with only about 1 false positive per image (FPpI). To achieve above results we carry out a progression following: Firstly, the input images are preprocessed with the aim to enhance key information of circumscribed masses; Next, we calculate and evaluate statistically basic features of abnormal regions on training database; Then, mammograms on testing database are divided into equal blocks which calculated corresponding features. Finally, using priority order of basic features to classify blocks as an abnormal or normal regions.

Keywords: mammograms, circumscribed masses, evaluated statistically, priority order of basic features

Procedia PDF Downloads 334
1399 Smoker Recognition from Lung X-Ray Images Using Convolutional Neural Network

Authors: Moumita Chanda, Md. Fazlul Karim Patwary

Abstract:

Smoking is one of the most popular recreational drug use behaviors, and it contributes to birth defects, COPD, heart attacks, and erectile dysfunction. To completely eradicate this disease, it is imperative that it be identified and treated. Numerous smoking cessation programs have been created, and they demonstrate how beneficial it may be to help someone stop smoking at the ideal time. A tomography meter is an effective smoking detector. Other wearables, such as RF-based proximity sensors worn on the collar and wrist to detect when the hand is close to the mouth, have been proposed in the past, but they are not impervious to deceptive variables. In this study, we create a machine that can discriminate between smokers and non-smokers in real-time with high sensitivity and specificity by watching and collecting the human lung and analyzing the X-ray data using machine learning. If it has the highest accuracy, this machine could be utilized in a hospital, in the selection of candidates for the army or police, or in university entrance.

Keywords: CNN, smoker detection, non-smoker detection, OpenCV, artificial Intelligence, X-ray Image detection

Procedia PDF Downloads 84
1398 A Turn-on Fluorescent Sensor for Pb(II)

Authors: Ece Kök Yetimoğlu, Soner Çubuk, Neşe Taşci, M. Vezir Kahraman

Abstract:

Lead(II) is one of the most toxic environmental pollutants in the world, due to its high toxicity and non-biodegradability. Lead exposure causes severe risks to human health such as central brain damages, convulsions, kidney damages, and even death. To determine lead(II) in environmental or biological samples, scientists use atomic absorption spectrometry (AAS), inductively coupled plasma mass spectrometry (ICPMS), fluorescence spectrometry and electrochemical techniques. Among these systems the fluorescence spectrometry and fluorescent chemical sensors have attracted considerable attention because of their good selectivity and high sensitivity. The fluorescent polymers usually contain covalently bonded fluorophores. In this study imidazole based UV cured polymeric film was prepared and designed to act as a fluorescence chemo sensor for lead (II) analysis. The optimum conditions such as influence of pH value and time on the fluorescence intensity of the sensor have also been investigated. The sensor was highly sensitive with a detection limit as low as 1.87 × 10−8 mol L-1 and it was successful in the determination of Pb(II) in water samples.

Keywords: fluorescence, lead(II), photopolymerization, polymeric sensor

Procedia PDF Downloads 671
1397 Development of a Non-Dispersive Infrared Multi Gas Analyzer for a TMS

Authors: T. V. Dinh, I. Y. Choi, J. W. Ahn, Y. H. Oh, G. Bo, J. Y. Lee, J. C. Kim

Abstract:

A Non-Dispersive Infrared (NDIR) multi-gas analyzer has been developed to monitor the emission of carbon monoxide (CO) and sulfur dioxide (SO2) from various industries. The NDIR technique for gas measurement is based on the wavelength absorption in the infrared spectrum as a way to detect particular gasses. NDIR analyzers have popularly applied in the Tele-Monitoring System (TMS). The advantage of the NDIR analyzer is low energy consumption and cost compared with other spectroscopy methods. However, zero/span drift and interference are its urgent issues to be solved. Multi-pathway technique based on optical White cell was employed to improve the sensitivity of the analyzer in this work. A pyroelectric detector was used to detect the Infrared radiation. The analytical range of the analyzer was 0 ~ 200 ppm. The instrument response time was < 2 min. The detection limits of CO and SO2 were < 4 ppm and < 6 ppm, respectively. The zero and span drift of 24 h was less than 3%. The linearity of the analyzer was less than 2.5% of reference values. The precision and accuracy of both CO and SO2 channels were < 2.5% of relative standard deviation. In general, the analyzer performed well. However, the detection limit and 24h drift should be improved to be a more competitive instrument.

Keywords: analyzer, CEMS, monitoring, NDIR, TMS

Procedia PDF Downloads 257
1396 Efficacy of Carvacrol as an Antimicrobial Wash Treatment for Reducing Both Campylobacter jejuni and Aerobic Bacterial Counts on Chicken Skin

Authors: Sandip Shrestha, Ann M. Donoghue, Komala Arsi, Basanta R. Wagle, Abhinav Upadhyay, Dan J. Donoghue

Abstract:

Campylobacter, one of the major cause of foodborne illness worldwide, is commonly present in the intestinal tract of poultry. Many strategies are currently being investigated to reduce Campylobacter counts on commercial poultry during processing with limited success. This study investigated the efficacy of the generally recognized as safe compound, carvacrol (CR), a component of wild oregano oil as a wash treatment for reducing C. jejuni and aerobic bacteria on chicken skin. A total of two trials were conducted, and in each trial, a total of 75 skin samples (4cm × 4cm each) were randomly allocated into 5 treatment groups (0%, 0.25%, 0.5%, 1% and 2% CR). Skin samples were inoculated with a cocktail of four wild strains of C. jejuni (~ 8 log10 CFU/skin). After 30 min of attachment, inoculated skin samples were dipped in the respective treatment solution for 1 min, allowed to drip dry for 2 min and processed at 0, 8, 24 h post treatment for enumeration of C. jejuni and aerobic bacterial counts (n=5/treatment/time point). The data were analyzed by ANOVA using PROC GLM procedure of SAS 9.3. All the tested doses of CR suspension consistently reduced C. jejuni counts across all time points. The 2% CR wash was the most effective treatment and reduced C. jejuni counts by ~4 log₁₀ CFU/sample (P < 0.05). Aerobic counts were reduced for the 0.5% CR dose at 0 and 24h in Trial 1 and at 0, 8 and 24h in Trial 2. The 1 and 2% CR doses consistently reduced aerobic counts in both trials up to 2 log₁₀ CFU/skin.

Keywords: Campylobacter jejuni, carvcrol, chicken skin, postharvest

Procedia PDF Downloads 181
1395 Preservation of Traditional Algerian Sausage Against Microbial Activity by the Garlic (Allium Sativum L.)

Authors: Abed Hannane, Rouag Noureddine

Abstract:

The present study aims to evaluate the association of fresh garlic (Allium sativum L.) and storage at 4°C in preserving the microbiological, nutritional, and sanitary quality of Merguez-type sausages prepared and sold locally from meat offal. The analysis focused on the evaluation of the microbiological quality of fifteen samples randomly taken from several butcheries in the wilaya of BBA, eastern Algeria. The bacteriological analysis revealed the presence of 6.88.10⁵ CFU/g of total aerobic bacteria, 5.39.10⁵ CFU/g of total coliforms, 2.23.10⁵ CFU/g of fecal coliforms, 2.43.103 CFU/g of Escherichia coli and 1.8.10⁵ CFU/g of coagulase-positive staphylococci, values higher than Algerian standards. The addition of fresh garlic as an antibacterial preservative at concentrations of 0.06, 0.12, 0.18, and 0.24 g/g to ground beef samples and stored in the refrigerator at 4°C for 15 days. The addition of garlic to Merguez made it possible to significantly reduce the presence of different bacterial groups during their refrigerated storage, compared to untreated meat, bringing it below the standards defined in the matter. Thus, the use of garlic as a food additive at a concentration of 0.12 g/g was sufficient to obtain levels according to Algerian standards equal to 1.8.10⁴ CFU/g of total aerobic bacteria, 9.48.10³ CFU/ g of total coliforms, 3.68.10³ UFC/g fecal coliforms, 4.56.10² UFC/g of E.coli 2.39.10⁴ UFC/g of coagulase-positive staphylococci. It is clear that thanks to the addition of garlic to Merguez, the sanitary quality has been improved by reducing the aerobic bacterial load and increasing the shelf life at 4°C.

Keywords: antimicrobial effect, garlic, sausage, storage

Procedia PDF Downloads 100
1394 Accuracy of Fitbit Charge 4 for Measuring Heart Rate in Parkinson’s Patients During Intense Exercise

Authors: Giulia Colonna, Jocelyn Hoye, Bart de Laat, Gelsina Stanley, Jose Key, Alaaddin Ibrahimy, Sule Tinaz, Evan D. Morris

Abstract:

Parkinson’s disease (PD) is the second most common neurodegenerative disease and affects approximately 1% of the world’s population. Increasing evidence suggests that aerobic physical exercise can be beneficial in mitigating both motor and non-motor symptoms of the disease. In a recent pilot study of the role of exercise on PD, we sought to confirm exercise intensity by monitoring heart rate (HR). For this purpose, we asked participants to wear a chest strap heart rate monitor (Polar Electro Oy, Kempele). The device sometimes proved uncomfortable. Looking forward to larger clinical trials, it would be convenient to employ a more comfortable and user friendly device. The Fitbit Charge 4 (Fitbit Inc) is a potentially comfortable, user-friendly solution since it is a wrist-worn heart rate monitor. Polar H10 has been used in large trials, and for our purposes, we treated it as the gold standard for the beat-to-beat period (R-R interval) assessment. In previous literature, it has been shown that Fitbit Charge 4 has comparable accuracy to Polar H10 in healthy subjects. It has yet to be determined if the Fitbit is as accurate as the Polar H10 in subjects with PD or in clinical populations, generally. Goal: To compare the Fitbit Charge 4 to the Polar H10 for monitoring HR in PD subjects engaging in an intensive exercise program. Methods: A total of 596 exercise sessions from 11 subjects (6 males) were collected simultaneously by both devices. Subjects with early-stage PD (Hoehn & Yahr <=2) were enrolled in a 6 months exercise training program designed for PD patients. Subjects participated in 3 one-hour exercise sessions per week. They wore both Fitbit and Polar H10 during each session. Sessions included rest, warm-up, intensive exercise, and cool-down periods. We calculated the bias in the HR via Fitbit under rest (5min) and intensive exercise (20min) by comparing the mean HR during each of the periods to the respective means measured by the Polar (HRFitbit – HRPolar). We also measured the sensitivity and specificity of Fitbit for detecting HRs that exceed the threshold for intensive exercise, defined as 70% of an individual’s theoretical maximum HR. Different types of correlation between the two devices were investigated. Results: The mean bias was 1.68 bpm at rest and 6.29 bpm during high intensity exercise, with an overestimation by Fitbit in both conditions. The mean bias of Fitbit across both rest and intensive exercise periods was 3.98 bpm. The sensitivity of the device in identifying high intensity exercise sessions was 97.14 %. The correlation between the two devices was non-linear, suggesting a saturation tendency of Fitbit to saturate at high values of HR. Conclusion: The performance of Fitbit Charge 4 is comparable to Polar H10 for assessing exercise intensity in a cohort of PD subjects. The device should be considered a reasonable replacement for the more cumbersome chest strap technology in future similar studies of clinical populations.

Keywords: fitbit, heart rate measurements, parkinson’s disease, wrist-wearable devices

Procedia PDF Downloads 109
1393 Treatment Outcome Of Corneal Ulcers Using Levofloxacin Hydrate 1.5% Ophthalmic Solution And Adjuvant Oral Ciprofloxacin, A Treatment Strategy Applicable To Primary Healthcare

Authors: Celine Shi Ying Lee, Jong Jian Lee

Abstract:

Background: Infectious keratitis is one of the leading causes of blindness worldwide. Prompt treatment with effective medication will control the infection early, preventing corneal scarring and visual loss. fluoroquinolones ophthalmic medication is used because of its broad-spectrum properties, potency, good intraocular penetration, and low toxicity. The study aims to evaluate the treatment outcome of corneal ulcers using Levofloxacin 1.5% ophthalmic solution (LVFX) with adjuvant oral ciprofloxacin when indicated and apply this treatment strategy in primary health care as first-line treatment. Methods: Patients with infective corneal ulcer treated in an eye center were recruited. Inclusion criteria includes Corneal infection consistent with bacterial keratitis, single or multiple small corneal ulcers. Treatment regime: LVFX hourly for the first 2 days, 2 hourly from the 3rd day, and 3 hourly on the 5th day of review. Adjuvant oral ciprofloxacin 500mg BD was administered for 5 days if there were multiple corneal ulcers or when the location of the cornea ulcer was central or paracentral. Results: 47 subjects were recruited. There were 16 (34%) males and 31 (66%) females. 40 subjects (85%) were contact lens (CL) related to corneal ulcer, and 7 subjects (15%) were non-contact lens related. 42 subjects (89%) presented with one ulcer, of which 20 of them (48%) needed adjuvant therapy. 5 subjects presented with 2 or 3 ulcers, of which 3 needed adjuvant therapy. A total of 23 subjects (49%) was given adjuvant therapy (oral ciprofloxacin 500mg BD for 5 days).21 of them (91%) were CL related. All subjects recovered fully, and the average duration of treatment was 3.7 days, with 49% of the subjects resolved on the 3rd day, 38% on the 5thday of and 13% on the 7thday. All subjects showed symptoms of relief of pain, light-sensitivity, and redness on the 3rd day with full visual recovery post-treatment. No adverse drug reactions were recorded. Conclusion: Our treatment regime demonstrated good clinical outcome as first-line treatment for corneal ulcers. A corneal ulcer is a common eye condition in Singapore, mainly due to CL wear. Pseudomonas aeruginosa is the most frequent and potentially sight-threatening pathogen involved in CL related corneal ulcer. Coagulase-negative Staphylococci, Staphylococcus aureus, and Streptococcus Pneumoniae were seen in non-CL users. All these bacteria exhibit good sensitivity rates to ciprofloxacin and levofloxacin. It is therefore logical in our study to use LVFX Eyedrops and adjuvant ciprofloxacin oral antibiotics when indicated as first line treatment for most corneal ulcers. Our study of patients, both CL related and non-CL related, have shown good clinical response and full recovery using the above treatment strategy. There was also a full restoration of visual acuity in all the patients. Eye-trained primary Healthcare practitioners can consider adopting this treatment strategy as first line treatment in patients with corneal ulcers. This is relevant during the COVID pandemic, where hospitals are overwhelmed with patients and in regions with limited access to specialist eye care. This strategy would enable early treatment with better clinical outcome.

Keywords: corneal ulcer, levofloxacin hydrate, treatment strategy, ciprofloxacin

Procedia PDF Downloads 175
1392 Indoor Temperature, Relative Humidity and CO₂ Level Assessment in a Publically Managed Hospital Building

Authors: Ayesha Asif, Muhammad Zeeshan

Abstract:

The sensitivity of hospital-microenvironments for all types of pollutants, due to the presence of patients with immune deficiencies, makes them complex indoor spaces. Keeping in view, this study investigated indoor air quality (IAQ) of two most sensitive places, i.e., operation theater (OT) and intensive care unit (ICU), of a publically managed hospital. Taking CO₂ concentration as air quality indicator and temperature (T) and relative humidity (RH) as thermal comfort parameters, continuous monitoring of the three variables was carried out. Measurements were recorded at an interval of 1 min for weekdays and weekends, including occupational and non-occupational hours. Outdoor T and RH measurements were also used in the analysis. Results show significant variation (p < 0.05) in CO₂, T and RH values over the day during weekdays while no significant variation (p > 0.05) have been observed during weekends of both the monitored sites. Maximum observed values of CO₂ in OT and ICU were found to be 2430 and 624 ppm, T as 24.7ºC and 28.9ºC and RH as 29.6% and 32.2% respectively.

Keywords: indoor air quality, CO₂ concentration, hospital building, comfort assessment

Procedia PDF Downloads 133
1391 PRISM: An Analytical Tool for Forest Plan Development

Authors: Dung Nguyen, Yu Wei, Eric Henderson

Abstract:

Analytical tools have been used for decades to assist in the development of forest plans. In 2016, a new decision support system, PRISM, was jointly developed by United States Forest Service (USFS) Northern Region and Colorado State University to support the forest planning process. Prism has a friendly user interface with functionality for database management, model development, data visualization, and sensitivity analysis. The software is tailored for USFS planning, but it is flexible enough to support planning efforts by other forestland owners and managers. Here, the core capability of PRISM and its applications in developing plans for several United States national forests are presented. The strengths of PRISM are also discussed to show its potential of being a preferable tool for managers and experts in the domain of forest management and planning.

Keywords: decision support, forest management, forest plan, graphical user interface, software

Procedia PDF Downloads 111
1390 Effect of Silver Nanoparticles on Seed Germination of Crop Plants

Authors: Zainab M. Almutairi, Amjad Alharbi

Abstract:

The use of engineered nanomaterials has increased as a result of their positive impact on many sectors of the economy, including agriculture. Silver nanoparticles (AgNPs) are now used to enhance seed germination, plant growth, and photosynthetic quantum efficiency and as antimicrobial agents to control plant diseases. In this study, we examined the effect of AgNP dosage on the seed germination of three plant species: corn (Zea mays L.), watermelon (Citrullus lanatus [Thunb.] Matsum. & Nakai) and zucchini (Cucurbita pepo L.). This experiment was designed to study the effect of AgNPs on germination percentage, germination rate, mean germination time, root length and fresh and dry weight of seedlings for the three species. Seven concentrations (0.05, 0.1, 0.5, 1, 1.5, 2, and 2.5 mg/ml) of AgNPs were examined at the seed germination stage. The three species had different dose responses to AgNPs in terms of germination parameters and the measured growth characteristics. The germination rates of the three plants were enhanced in response to AgNPs. Significant enhancement of the germination percentage values was observed after treatment of the watermelon and zucchini plants with AgNPs in comparison with untreated seeds. AgNPs showed a toxic effect on corn root elongation, whereas watermelon and zucchini seedling growth were positively affected by certain concentrations of AgNPs. This study showed that exposure to AgNPs caused both positive and negative effects on plant growth and germination.

Keywords: citrullus lanatus, cucurbita pepo, seed germination, seedling growth, silver nanoparticles, zea mays

Procedia PDF Downloads 308
1389 Detection of Nutrients Using Honeybee-Mimic Bioelectronic Tongue Systems

Authors: Soo Ho Lim, Minju Lee, Dong In Kim, Gi Youn Han, Seunghun Hong, Hyung Wook Kwon

Abstract:

We report a floating electrode-based bioelectronic tongue mimicking honeybee taste systems for the detection and discrimination of various nutrients. Here, carbon nanotube field effect transistors with floating electrodes (CNT-FET) were hybridized with nanovesicles containing honeybee nutrient receptors, gustatory receptors of Apis mellifera. This strategy enables us to detect nutrient substance with a high sensitivity and selectivity. It could also be utilized for the detection of nutrients in liquid food. This floating electrode-based bioelectronic tongue mimicking insect taste systems can be a simple, but highly effective strategy in many different basic research areas about sensory systems. Moreover, our research provides opportunities to develop various applications such as food screening, and it also can provide valuable insights on insect taste systems.

Keywords: taste system, CNT-FET, insect gustatory receptor, biolelectronic tongue

Procedia PDF Downloads 218
1388 Green Synthesis of Silver Nanoparticles by Olive Leaf Extract: Application in the Colorimetric Detection of Fe+3 Ions

Authors: Nasibeh Azizi Khereshki

Abstract:

Olive leaf (OL) extract as a green reductant agent was utilized for the biogenic synthesis of silver nanoparticles (Ag NPs) for the first time in this study, and then its performance was evaluated for colorimetric detection of Fe3+ in different media. Some analytical methods were used to characterize the nanosensor. The effective sensing parameters were optimized by central composite design (CCD) combined with response surface methodology (RSM) application. Then, the prepared material's applicability in antibacterial and optical chemical sensing for naked-eye detection of Fe3+ ions in aqueous solutions were evaluated. Furthermore, OL-Ag NPs-loaded paper strips were successfully applied to the colorimetric visualization of Fe3+. The colorimetric probe based on OL-AgNPs illustrated excellent selectivity and sensitivity towards Fe3+ ions, with LOD and LOQ of 0.81 μM and 2.7 μM, respectively. In addition, the developed method was applied to detect Fe3+ ions in real water samples and validated with a 95% confidence level against a reference spectroscopic method.

Keywords: Ag NPs, colorimetric detection, Fe(III) ions, green synthesis, olive leaves

Procedia PDF Downloads 77
1387 Clinical and Analytical Performance of Glial Fibrillary Acidic Protein and Ubiquitin C-Terminal Hydrolase L1 Biomarkers for Traumatic Brain Injury in the Alinity Traumatic Brain Injury Test

Authors: Raj Chandran, Saul Datwyler, Jaime Marino, Daniel West, Karla Grasso, Adam Buss, Hina Syed, Zina Al Sahouri, Jennifer Yen, Krista Caudle, Beth McQuiston

Abstract:

The Alinity i TBI test is Therapeutic Goods Administration (TGA) registered and is a panel of in vitro diagnostic chemiluminescent microparticle immunoassays for the measurement of glial fibrillary acidic protein (GFAP) and ubiquitin C-terminal hydrolase L1 (UCH-L1) in plasma and serum. The Alinity i TBI performance was evaluated in a multi-center pivotal study to demonstrate the capability to assist in determining the need for a CT scan of the head in adult subjects (age 18+) presenting with suspected mild TBI (traumatic brain injury) with a Glasgow Coma Scale score of 13 to 15. TBI has been recognized as an important cause of death and disability and is a growing public health problem. An estimated 69 million people globally experience a TBI annually1. Blood-based biomarkers such as glial fibrillary acidic protein (GFAP) and ubiquitin C-terminal hydrolase L1 (UCH-L1) have shown utility to predict acute traumatic intracranial injury on head CT scans after TBI. A pivotal study using prospectively collected archived (frozen) plasma specimens was conducted to establish the clinical performance of the TBI test on the Alinity i system. The specimens were originally collected in a prospective, multi-center clinical study. Testing of the specimens was performed at three clinical sites in the United States. Performance characteristics such as detection limits, imprecision, linearity, measuring interval, expected values, and interferences were established following Clinical and Laboratory Standards Institute (CLSI) guidance. Of the 1899 mild TBI subjects, 120 had positive head CT scan results; 116 of the 120 specimens had a positive TBI interpretation (Sensitivity 96.7%; 95% CI: 91.7%, 98.7%). Of the 1779 subjects with negative CT scan results, 713 had a negative TBI interpretation (Specificity 40.1%; 95% CI: 37.8, 42.4). The negative predictive value (NPV) of the test was 99.4% (713/717, 95% CI: 98.6%, 99.8%). The analytical measuring interval (AMI) extends from the limit of quantitation (LoQ) to the upper LoQ and is determined by the range that demonstrates acceptable performance for linearity, imprecision, and bias. The AMI is 6.1 to 42,000 pg/mL for GFAP and 26.3 to 25,000 pg/mL for UCH-L1. Overall, within-laboratory imprecision (20 day) ranged from 3.7 to 5.9% CV for GFAP and 3.0 to 6.0% CV for UCH-L1, when including lot and instrument variances. The Alinity i TBI clinical performance results demonstrated high sensitivity and high NPV, supporting the utility to assist in determining the need for a head CT scan in subjects presenting to the emergency department with suspected mild TBI. The GFAP and UCH-L1 assays show robust analytical performance across a broad concentration range of GFAP and UCH-L1 and may serve as a valuable tool to help evaluate TBI patients across the spectrum of mild to severe injury.

Keywords: biomarker, diagnostic, neurology, TBI

Procedia PDF Downloads 66
1386 The Mechanical Behavior of a Cement-Fiber Composite Material

Authors: K. Harrat, M. Hidjeb, M. T’kint

Abstract:

The aim of the present research work is to characterize a cement palm date fiber composite in order to be used in isolation and in the manufacture of new structural materials. This technique may possibly participate seriously in the preservation of the environment and develop a growing need for plant products. On one hand, It has been shown that the presence of natural fiber in the composite materials manufacture, based on hydraulic binder, has improved the mechanical behaviour of the material. On the Other hand, It has been proven that the durability of composite materials reinforced with untreated fibers was largely affected by the presence of organic matter. In order to extract the organic material, the fibers were treated with boiling water and then coated with different types of products. A considerable improvement in the sensitivity to water of the fibers, as well as in the mechanical strength and in the ductility of the composite material was observed. The fiber being sensitive to water, the study put the emphasis on its dimensional stability.

Keywords: cement composite, durability, heat treatment, mechanical behaviour, vegetal fiber

Procedia PDF Downloads 454
1385 Microwave Assisted Synthesis and Metal Complexes of Some Copolymers Based on Itaconic Acid

Authors: Mohamed H. El-Newehy, Sameh M. Osman, Moamen S. Refat, Salem S. Al-Deyab, Ayman El-Faham

Abstract:

The two copolymers itaconic acid-methyl methacrylate and itaconic acid-acrylamide have been prepared in different ratio by radical copolymerization in the presence of azobisisobutyronitrile (AIBN) as initiator and using 2-butanone as reaction medium using microwave irradiation. The microwave technique is safe, fast, and gives high yield of the products with high purity in an optimum time, comparing to the traditional conventional heating. All the prepared copolymers were characterized by FT-IR, thermal analysis and elemental microanalysis. The itaconic acid-based copolymers showed a good sensitivity in alkaline media for scavenging Cu (II) and Pb (II). The chelation behavior of both Cu (II) and Pb (II) complexes were checked using FT-IR, thermogravimetric analysis (TGA), and differential scanning calorimetery (DSC). The infrared data are in a good agreement with the coordination through carboxylate-to-metal, in which the copolymers acting as a bidentate ligand.

Keywords: microwave synthesis, itaconic acid, copolymerization, scavenging, thermal stability

Procedia PDF Downloads 458
1384 Molding Properties of Cobalt-Chrome-Based Feedstocks Used in Low-Pressure Powder Injection Molding

Authors: Ehsan Gholami, Vincent Demers

Abstract:

Low-pressure powder injection molding is an emerging technology for cost-effectively producing complex shape metallic parts with the proper dimensional tolerances, either in high or in low production volumes. In this study, the molding properties of cobalt-chrome-based feedstocks were evaluated for use in a low-pressure powder injection molding process. The rheological properties of feedstock formulations were obtained by mixing metallic powder with a proprietary wax-based binder system. Rheological parameters such as reference viscosity, shear rate sensitivity index, and activation energy for viscous flow, were extracted from the viscosity profiles and introduced into the Weir model to calculate the moldability index. Feedstocks were experimentally injected into a spiral mold cavity to validate the injection performance calculated with the model.

Keywords: binder, feedstock, moldability, powder injection molding, viscosity

Procedia PDF Downloads 274
1383 Evaluation of Risk and the Beneficial Effects of Synthesized Nano Silver-Based Disinfectant on Poultry Mortality and Health

Authors: Indrajeet Kumar, Jayanta Bhattacharya

Abstract:

This study was evaluated for the potential use of nanosilver (nAg) as a disinfectant and antimicrobial growth promoter supplement for the poultry. The experiments were conducted in the Kangsabati river basin region, in West Medinipur district, West Bengal, India for six months. Two poultry farms were adopted for the experiment. The rural economy of this region from Jhargram to Barkola is heavily dependent on contract poultry farming. The water samples were collected from the water source of poultry farm which has been used for poultry drinking purpose. The bacteriological analysis of water sample revealed that the total bacterial count (total coliform and E. coli) were higher than the acceptable standards. The bacterial loads badly affected the growth performance and health of the poultry. For disinfection, a number of chemical compounds (like formaldehyde, calcium hypochloride, sodium hypochloride, and sodium bicarbonate) have been used in typical commercial formulations. However, the effects of all these chemical compounds have not been significant over time. As a part of our research-to-market initiative, we used nanosilver (nAg) formulation as a disinfectant. The nAg formulation was synthesized by hydrothermal technique and characterized by UV-visible, TEM, SEM, and EDX. The obtained results revealed that the mortality rate of poultry was reduced due to nAg formulation compared to the mortality rate of the negative control. Moreover, the income of the farmer family was increased by 10-20% due to less mortality and better health of the poultry.

Keywords: farm water, nanosilver, field application, and poultry performance

Procedia PDF Downloads 162
1382 Ensemble-Based SVM Classification Approach for miRNA Prediction

Authors: Sondos M. Hammad, Sherin M. ElGokhy, Mahmoud M. Fahmy, Elsayed A. Sallam

Abstract:

In this paper, an ensemble-based Support Vector Machine (SVM) classification approach is proposed. It is used for miRNA prediction. Three problems, commonly associated with previous approaches, are alleviated. These problems arise due to impose assumptions on the secondary structural of premiRNA, imbalance between the numbers of the laboratory checked miRNAs and the pseudo-hairpins, and finally using a training data set that does not consider all the varieties of samples in different species. We aggregate the predicted outputs of three well-known SVM classifiers; namely, Triplet-SVM, Virgo and Mirident, weighted by their variant features without any structural assumptions. An additional SVM layer is used in aggregating the final output. The proposed approach is trained and then tested with balanced data sets. The results of the proposed approach outperform the three base classifiers. Improved values for the metrics of 88.88% f-score, 92.73% accuracy, 90.64% precision, 96.64% specificity, 87.2% sensitivity, and the area under the ROC curve is 0.91 are achieved.

Keywords: MiRNAs, SVM classification, ensemble algorithm, assumption problem, imbalance data

Procedia PDF Downloads 349
1381 Feature Selection for Production Schedule Optimization in Transition Mines

Authors: Angelina Anani, Ignacio Ortiz Flores, Haitao Li

Abstract:

The use of underground mining methods have increased significantly over the past decades. This increase has also been spared on by several mines transitioning from surface to underground mining. However, determining the transition depth can be a challenging task, especially when coupled with production schedule optimization. Several researchers have simplified the problem by excluding operational features relevant to production schedule optimization. Our research objective is to investigate the extent to which operational features of transition mines accounted for affect the optimal production schedule. We also provide a framework for factors to consider in production schedule optimization for transition mines. An integrated mixed-integer linear programming (MILP) model is developed that maximizes the NPV as a function of production schedule and transition depth. A case study is performed to validate the model, with a comparative sensitivity analysis to obtain operational insights.

Keywords: underground mining, transition mines, mixed-integer linear programming, production schedule

Procedia PDF Downloads 169
1380 Multiscale Modelization of Multilayered Bi-Dimensional Soils

Authors: I. Hosni, L. Bennaceur Farah, N. Saber, R Bennaceur

Abstract:

Soil moisture content is a key variable in many environmental sciences. Even though it represents a small proportion of the liquid freshwater on Earth, it modulates interactions between the land surface and the atmosphere, thereby influencing climate and weather. Accurate modeling of the above processes depends on the ability to provide a proper spatial characterization of soil moisture. The measurement of soil moisture content allows assessment of soil water resources in the field of hydrology and agronomy. The second parameter in interaction with the radar signal is the geometric structure of the soil. Most traditional electromagnetic models consider natural surfaces as single scale zero mean stationary Gaussian random processes. Roughness behavior is characterized by statistical parameters like the Root Mean Square (RMS) height and the correlation length. Then, the main problem is that the agreement between experimental measurements and theoretical values is usually poor due to the large variability of the correlation function, and as a consequence, backscattering models have often failed to predict correctly backscattering. In this study, surfaces are considered as band-limited fractal random processes corresponding to a superposition of a finite number of one-dimensional Gaussian process each one having a spatial scale. Multiscale roughness is characterized by two parameters, the first one is proportional to the RMS height, and the other one is related to the fractal dimension. Soil moisture is related to the complex dielectric constant. This multiscale description has been adapted to two-dimensional profiles using the bi-dimensional wavelet transform and the Mallat algorithm to describe more correctly natural surfaces. We characterize the soil surfaces and sub-surfaces by a three layers geo-electrical model. The upper layer is described by its dielectric constant, thickness, a multiscale bi-dimensional surface roughness model by using the wavelet transform and the Mallat algorithm, and volume scattering parameters. The lower layer is divided into three fictive layers separated by an assumed plane interface. These three layers were modeled by an effective medium characterized by an apparent effective dielectric constant taking into account the presence of air pockets in the soil. We have adopted the 2D multiscale three layers small perturbations model including, firstly air pockets in the soil sub-structure, and then a vegetable canopy in the soil surface structure, that is to simulate the radar backscattering. A sensitivity analysis of backscattering coefficient dependence on multiscale roughness and new soil moisture has been performed. Later, we proposed to change the dielectric constant of the multilayer medium because it takes into account the different moisture values of each layer in the soil. A sensitivity analysis of the backscattering coefficient, including the air pockets in the volume structure with respect to the multiscale roughness parameters and the apparent dielectric constant, was carried out. Finally, we proposed to study the behavior of the backscattering coefficient of the radar on a soil having a vegetable layer in its surface structure.

Keywords: multiscale, bidimensional, wavelets, backscattering, multilayer, SPM, air pockets

Procedia PDF Downloads 125
1379 Preparation of Essential Oil Capsule (Carum Copticum) In Chitosan Nanoparticles and Investigation of Its Biological Properties

Authors: Akbar Esmaeili, Azadeh Asgari

Abstract:

Essential oils’ unique and practical properties have been widely reported in recent years. Still, the sensitivity of critical oils to environmental factors and their poor solubility in aqueous solutions have limited their use in industries. Therefore, we encapsulated C. copticum essential oil in chitosan nanoparticles by emulsion-ionic gelation with sodium tripolyphosphate and sodium hexametaphosphate cross-linkers. The nanoparticles showed a round shape with an average size of 30-80 nm and a regular distribution. The release profile in the laboratory environment showed a burst in the initial release and then a stable release of C. copticum essential oil from chitosan nanoparticles at different pH. Antioxidant and antibacterial properties of C. copticum essential oil before and after the encapsulation process were evaluated by 2,2-diphenyl-1-picrylhydrazyl radical and disc diffusion methods, respectively. The results showed that the encapsulation of C. copticum essential oil in chitosan nanoparticles could protect its quality and bioactive compounds and improve the properties of the crucial oil.

Keywords: essential oils, Carum copticum, biological activities, nanotechnology

Procedia PDF Downloads 87
1378 Development of Hit Marks on Clothes Using Amino Acid Reagents

Authors: Hyo-Su Lim, Ye-Eun Song, Eun-Bi Lee, Sang-Yoon Lee, Young-Il Seo, Jin-Pyo Kim, Nam-Kyu Park

Abstract:

If we analogize any physical external force given to victims in many crimes including violence, it would be possible not only to presume mutual action between victims and suspects, but to make a deduction of more various facts in cases. Therefore, the aim of this study is to identify criminal tools through secretion on clothes by using amino acid reagents such as Ninhydrin, DFO(1,8-dizafluoren-9-one), 1,2 – IND (1,2-indanedione) which are reacting to skin secretion. For more effective collecting condition, porcine skin which is physiologically similar to human was used. Although there were little differences of shape identification according to sensitivity, amino acid reagents were able to identify the fist, foot, and baseball bat. Furthermore, we conducted the experiments for developmental variations through change over time setting up 5-weeks period including first damage as variation factor, and developing materials in each action through certain reagents. Specimen level of development depending on change over time was identified. As a result, each of initial level of development was seen no changes.

Keywords: hit marks, amino acid reagents, porcine skin, criminal tool

Procedia PDF Downloads 263