Search results for: pelvic fracture
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 736

Search results for: pelvic fracture

136 Rule-Of-Mixtures: Predicting the Bending Modulus of Unidirectional Fiber Reinforced Dental Composites

Authors: Niloofar Bahramian, Mohammad Atai, Mohammad Reza Naimi-Jamal

Abstract:

Rule of mixtures is the simple analytical model is used to predict various properties of composites before design. The aim of this study was to demonstrate the benefits and limitations of the Rule-of-Mixtures (ROM) for predicting bending modulus of a continuous and unidirectional fiber reinforced composites using in dental applications. The Composites were fabricated from light curing resin (with and without silica nanoparticles) and modified and non-modified fibers. Composite samples were divided into eight groups with ten specimens for each group. The bending modulus (flexural modulus) of samples was determined from the slope of the initial linear region of stress-strain curve on 2mm×2mm×25mm specimens with different designs: fibers corona treatment time (0s, 5s, 7s), fibers silane treatment (0%wt, 2%wt), fibers volume fraction (41%, 33%, 25%) and nanoparticles incorporation in resin (0%wt, 10%wt, 15%wt). To study the fiber and matrix interface after fracture, single edge notch beam (SENB) method and scanning electron microscope (SEM) were used. SEM also was used to show the nanoparticles dispersion in resin. Experimental results of bending modulus for composites made of both physical (corona) and chemical (silane) treated fibers were in reasonable agreement with linear ROM estimates, but untreated fibers or non-optimized treated fibers and poor nanoparticles dispersion did not correlate as well with ROM results. This study shows that the ROM is useful to predict the mechanical behavior of unidirectional dental composites but fiber-resin interface and quality of nanoparticles dispersion play important role in ROM accurate predictions.

Keywords: bending modulus, fiber reinforced composite, fiber treatment, rule-of-mixtures

Procedia PDF Downloads 276
135 Physical Activity, Exercise and Physical Fitness in Different Generation

Authors: Carl J. Caspersen, Kenneth E. Powell, Gregory M. Christenson, Kirupa V. Patel

Abstract:

‘Physical activity’, ‘exercise’, and ‘physical fitness’ are terms that describe different concepts. However, they are often confused with one another, and the terms are sometimes used interchangeably. This paper proposes definitions to distinguish them. Physical activity is defined as any bodily movement produced by skeletal muscles that result in energy expenditure. The energy expenditure can be measured in kilocalories. Physical activity in daily life can be categorized into occupational, sports, Conditioning, household, or other activities. Exercise is a subset of physical activity that is planned, structured, and repetitive and has as a final or an intermediate objective the improvement or maintenance of physical fitness. Physical fitness is a set of attributes that are either health- or skill-related. The degree to which people have these attributes can be measured with specific tests. These definitions are offered as an interpretational framework for comparing studies that relate physical activity, exercise, and physical fitness to health. Physical activity is defined as any bodily movement produced by skeletal muscles that require energy expenditure. Physical inactivity has been identified as the fourth leading risk factor for global mortality causing an estimated 3.2 million deaths globally. Regular moderate intensity physical activity – such as walking, cycling, or participating in sports – has significant benefits for health. For instance, it can reduce the risk of cardiovascular diseases, diabetes, colon and breast cancer, and depression. Moreover, adequate levels of physical activity will decrease the risk of a hip or vertebral fracture and help control weight. Any bodily movement produced by the contraction of skeletal muscle that increases energy expenditure above a basal level. In these guidelines, physical activity generally refers to the subset of physical activity that enhances health.

Keywords: physical activity, exercise, physical fitness, sports

Procedia PDF Downloads 362
134 The Role of Movement Quality after Osgood-Schlatter Disease in an Amateur Football Player: A Case Study

Authors: D. Pogliana, A. Maso, N. Milani, D. Panzin, S. Rivaroli, J. Konin

Abstract:

This case aims to identify the role of movement quality during the final stage of return to sport (RTS) in a male amateur football player 13 years old after passing the acute phase of the bilateral Osgood-Schlatter disease (OSD). The patient, after a year from passing the acute phase of OSD with the abstention of physical activity, reports bilateral anterior knee pain at the beginning of the football sport activity. Interventions: After the orthopedist check, who recommended physiotherapy sessions for the correction of motor patterns and the isometric reinforcement of the muscles of the quadriceps, the rehabilitation intervention was developed in 7 weeks through 14 sessions of neuro-motor training (NMT) with a frequency of two weekly sessions and six sessions of muscle-strengthening with a frequency of one weekly session. The sessions of NMT were carried out through free body exercises (or with overloads) with visual bio-feedback with the help of two cameras (one with anterior vision and one with lateral vision of the subject) and a big touch screen. The aim of these sessions of NMT was to modify the dysfunctional motor patterns evaluated by the 2D motion analysis test. The test was carried out at the beginning and at the end of the rehabilitation course and included five movements: single-leg squat (SLS), drop jump (DJ), single-leg hop (SLH), lateral shuffle (LS), and change of direction (COD). Each of these movements was evaluated through the video analysis of dynamic valgus knee, pelvic tilt, trunk control, shock absorption, and motor strategy. A free image analysis software (Kinovea) was then used to calculate scores. Results: Baseline assessment of the subject showed a total score of 59% on the right limb and 64% on the left limb (considering an optimal score above 85%) with large deficits in shock absorption capabilities, the presence of dynamic valgus knee, and dysfunctional motor strategies defined “quadriceps dominant.” After six weeks of training, the subject achieved a total score of 80% on the right limb and 86% on the left limb, with significant improvements in shock absorption capabilities, the presence of dynamic knee valgus, and the employment of more hip-oriented motor strategies on both lower limbs. The improvements shown in dynamic knee valgus, greater hip-oriented motor strategies, and improved shock absorption identified through six weeks of the NMT program can help a teenager amateur football player to manage the anterior knee pain during sports activity. In conclusion, NMT was a good choice to help a 13 years old male amateur football player to return to performance without pain after OSD and can also be used with all this type of athletes of the other teams' sports.

Keywords: movement analysis, neuro-motor training, knee pain, movement strategies

Procedia PDF Downloads 138
133 Fatigue Behavior of Friction Stir Welded EN AW 5754 Aluminum Alloy Using Load Increase Procedure

Authors: A. B. Chehreh, M. Grätzel, M. Klein, J. P. Bergmann, F. Walther

Abstract:

Friction stir welding (FSW) is an advantageous method in the thermal joining processes, featuring the welding of various dissimilar and similar material combinations, joining temperatures below the melting point which prevents irregularities such as pores and hot cracks as well as high strengths mechanical joints near the base material. The FSW process consists of a rotating tool which is made of a shoulder and a probe. The welding process is based on a rotating tool which plunges in the workpiece under axial pressure. As a result, the material is plasticized by frictional heat which leads to a decrease in the flow stress. During the welding procedure, the material is continuously displaced by the tool, creating a firmly bonded weld seam behind the tool. However, the mechanical properties of the weld seam are affected by the design and geometry of the tool. These include in particular microstructural and surface properties which can favor crack initiation. Following investigation compares the dynamic properties of FSW weld seams with conventional and stationary shoulder geometry based on load increase test (LIT). Compared to classical Woehler tests, it is possible to determine the fatigue strength of the specimens after a short amount of time. The investigations were carried out on a robotized welding setup on 2 mm thick EN AW 5754 aluminum alloy sheets. It was shown that an increased tensile and fatigue strength can be achieved by using the stationary shoulder concept. Furthermore, it could be demonstrated that the LIT is a valid method to describe the fatigue behavior of FSW weld seams.

Keywords: aluminum alloy, fatigue performance, fracture, friction stir welding

Procedia PDF Downloads 153
132 Microvoid Growth in the Interfaces during Aging

Authors: Jae-Yong Park, Gwancheol Seo, Young-Ho Kim

Abstract:

Microvoids, sometimes called Kikendall voids, generally form in the interfaces between Sn-based solders and Cu and degrade the mechanical and electrical properties of the solder joints. The microvoid formation is known as the rapid interdiffusion between Sn and Cu and impurity content in the Cu. Cu electroplating from the acid solutions has been widely used by microelectronic packaging industry for both printed circuit board (PCB) and integrated circuit (IC) applications. The quality of electroplated Cu that can be optimized by the electroplating conditions is critical for the solder joint reliability. In this paper, the influence of electroplating conditions on the microvoid growth in the interfaces between Sn-3.0Ag-0.5Cu (SAC) solder and Cu layer was investigated during isothermal aging. The Cu layers were electroplated by controlling the additive of electroplating bath and current density to induce various microvoid densities. The electroplating bath consisted of sulfate, sulfuric acid, and additives and the current density of 5-15 mA/cm2 for each bath was used. After aging at 180 °C for up to 250 h, typical bi-layer of Cu6Sn5 and Cu3Sn intermetallic compounds (IMCs) was gradually growth at the SAC/Cu interface and microvoid density in the Cu3Sn showed disparities in the electroplating conditions. As the current density increased, the microvoid formation was accelerated in all electroplating baths. The higher current density induced, the higher impurity content in the electroplated Cu. When the polyethylene glycol (PEG) and Cl- ion were mixed in an electroplating bath, the microvoid formation was the highest compared to other electroplating baths. On the other hand, the overall IMC thickness was similar in all samples irrespective of the electroplating conditions. Impurity content in electroplated Cu influenced the microvoid growth, but the IMC growth was not affected by the impurity content. In conclusion, the electroplated conditions are properly optimized to avoid the excessive microvoid formation that results in brittle fracture of solder joint under high strain rate loading.

Keywords: electroplating, additive, microvoid, intermetallic compound

Procedia PDF Downloads 262
131 Development of 3D Printed, Conductive, Biodegradable Nerve Conduits for Neural Regeneration

Authors: Wei-Chia Huang, Jane Wang

Abstract:

Damage to nerves is considered one of the most irreversible injuries. The regeneration of nerves has always been an important topic in regenerative medicine. In general, damage to human tissue will naturally repair overtime. However, when the nerves are damaged, healed flesh wound cannot guarantee full restoration to its original function, as truncated nerves are often irreversible. Therefore, the development of treatment methods to successfully guide and accelerate the regeneration of nerves has been highly sought after. In order to induce nerve tissue growth, nerve conduits are commonly used to help reconnect broken nerve bundles to provide protection to the location of the fracture while guiding the growth of the nerve bundles. To prevent the protected tissue from becoming necrotic and to ensure the growth rate, the conduits used are often modified with microstructures or blended with neuron growth factors that may facilitate nerve regeneration. Electrical stimulation is another attempted treatment for medical rehabilitation. With appropriate range of voltages and stimulation frequencies, it has been demonstrated to promote cell proliferation and migration. Biodegradability are critical for medical devices like nerve conduits, while conductive polymers pose great potential toward the differentiation and growth of nerve cells. In this work, biodegradability and conductivity were combined into a novel biodegradable, photocurable, conductive polymer composite materials by embedding conductive nanoparticles in poly(glycerol sebacate) acrylate (PGSA) and 3D-printed into nerve conduits. Rat pheochromocytoma cells and rat neuronal Schwann cells were chosen for the in vitro tests of the conduits and had demonstrate selective growth upon culture in the conductive conduits with built-in microchannels and electrical stimulation.

Keywords: biodegradable polymer, 3d printing, neural regeneration, electrical stimulation

Procedia PDF Downloads 104
130 Forgeability Study of Medium Carbon Micro-Alloyed Forging Steel

Authors: M. I. Equbal, R. K. Ohdar, B. Singh, P. Talukdar

Abstract:

Micro-alloyed steel components are used in automotive industry for the necessity to make the manufacturing process cycles shorter when compared to conventional steel by eliminating heat treatment cycles, so an important saving of costs and energy can be reached by reducing the number of operations. Micro-alloying elements like vanadium, niobium or titanium have been added to medium carbon steels to achieve grain refinement with or without precipitation strengthening along with uniform microstructure throughout the matrix. Present study reports the applicability of medium carbon vanadium micro-alloyed steel in hot forging. Forgeability has been determined with respect to different cooling rates, after forging in a hydraulic press at 50% diameter reduction in temperature range of 900-11000C. Final microstructures, hardness, tensile strength, and impact strength have been evaluated. The friction coefficients of different lubricating conditions, viz., graphite in hydraulic oil, graphite in furnace oil, DF 150 (Graphite, Water-Based) die lubricant and dry or without any lubrication were obtained from the ring compression test for the above micro-alloyed steel. Results of ring compression tests indicate that graphite in hydraulic oil lubricant is preferred for free forging and dry lubricant is preferred for die forging operation. Exceptionally good forgeability and high resistance to fracture, especially for faster cooling rate has been observed for fine equiaxed ferrite-pearlite grains, some amount of bainite and fine precipitates of vanadium carbides and carbonitrides. The results indicated that the cooling rate has a remarkable effect on the microstructure and mechanical properties at room temperature.

Keywords: cooling rate, hot forging, micro-alloyed, ring compression

Procedia PDF Downloads 361
129 On Crack Tip Stress Field in Pseudo-Elastic Shape Memory Alloys

Authors: Gulcan Ozerim, Gunay Anlas

Abstract:

In shape memory alloys, upon loading, stress increases around crack tip and a martensitic phase transformation occurs in early stages. In many studies the stress distribution in the vicinity of the crack tip is represented by using linear elastic fracture mechanics (LEFM) although the pseudo-elastic behavior results in a nonlinear stress-strain relation. In this study, the HRR singularity (Hutchinson, Rice and Rosengren), that uses Rice’s path independent J-integral, is tried to formulate the stress distribution around the crack tip. In HRR approach, the Ramberg-Osgood model for the stress-strain relation of power-law hardening materials is used to represent the elastic-plastic behavior. Although it is recoverable, the inelastic portion of the deformation in martensitic transformation (up to the end of transformation) resembles to that of plastic deformation. To determine the constants of the Ramberg-Osgood equation, the material’s response is simulated in ABAQUS using a UMAT based on ZM (Zaki-Moumni) thermo-mechanically coupled model, and the stress-strain curve of the material is plotted. An edge cracked shape memory alloy (Nitinol) plate is loaded quasi-statically under mode I and modeled using ABAQUS; the opening stress values ahead of the cracked tip are calculated. The stresses are also evaluated using the asymptotic equations of both LEFM and HRR. The results show that in the transformation zone around the crack tip, the stress values are much better represented when the HRR singularity is used although the J-integral does not show path independent behavior. For the nodes very close to the crack tip, the HRR singularity is not valid due to the non-proportional loading effect and high-stress values that go beyond the transformation finish stress.

Keywords: crack, HRR singularity, shape memory alloys, stress distribution

Procedia PDF Downloads 326
128 Usage Of the Transpedicular Screw Fixation Method in the Treatment of Pediatric Patients with Injuries of the Thoracic and Lumbar Spine.

Authors: S. D. Zalepugin, A. E. Murzich, D. G. Satskevich, A. B. Palivanov

Abstract:

Introduction. The incidence of spinal injuries in patients under 18 years of age has increased significantly in recent years, which represents a significant economic, social and medical problem. The most common method of surgical stabilization of spinal fractures in pediatric patients is transpedicular posterior spinal fusion, which is widely used by spinal neurosurgeons in adult patients. Purpose of the study: This study evaluates the results of treatment of thoracolumbar spine lesions in children using the transpedicular screw fixation method. Materials and methods. From 2019 to 2024, 35 children with injuries to the thoracic and lumbar spine underwent surgical treatment using the transpedicular screw fixation method. Among the injured, girls prevailed (21 cases, 60%). The age of the victims ranged from 9 to 17 years. The main causes of damage were: catatrauma (19 cases), road accident (5 cases), sports injury (6 cases), and other reasons - 5 cases. In 5 cases, suicidal attempts occurred. Co-injury was observed in most cases (20 patients, or 57%), which is natural for high-energy injury. Vertebral-spinal injury with neurological disorders was observed in 13 patients, the disorders ranged from mild inferior (4 children) to moderate/severe paraparesis (5 patients) and inferior paraplegia (4 children). 6 children had pelvic organ dysfunction in the form of urinary and fecal retention or incontinence. All thirty-five patients, within a period of 1 to 57 days after the injury, underwent several surgical interventions from the posterior surgical access using a screw fixation method (posterior decompression + spinal fusion). In 12 cases, it was necessary to perform the second stage of surgical treatment - anterior decompression of the spinal cord or its roots. Verticalization of patients was carried out within 1 to 5 days after surgery. Results. In all patients, the nearest, up to 1 year, results were evaluated. In children operated in 2019-2021, the results were studied in terms of 3 to 5 years. The procedures used, clinical results and the quality of the fixative installation were assessed. All patients managed to achieve positive results. The use of internal fixation made it possible to carry out early verticalization of children, eliminate pain syndrome and achieve a regression of neurological disorders in most patients (especially in cases when the operation was performed early after injury - from 1 to 3 days). Within the first month, the ability to self-care was fully restored. Bone fusion was observed within 6-12 months after surgery. There were no complications after surgery. The analysis of postoperative radiographs, CT and MRI images revealed the correct standing of the screws in all cases. Conclusion. The posterior spinal fusion using the new method of screw fixation in pediatric patients allows to achieve durable stabilization of damage, begins early rehabilitation of patients and reduces the duration of hospital treatment by 2-3 times. Thus, we recommend the use of a transpedicular fixator in children as a reliable, technically feasible method for restoring spinal stability with a low risk of intra- and postoperative complications.

Keywords: pediatric patients, spinal injuries, transpedicular stabilization, operative treatment

Procedia PDF Downloads 12
127 Design of Hybrid Auxetic Metamaterials for Enhanced Energy Absorption under Compression

Authors: Ercan Karadogan, Fatih Usta

Abstract:

Auxetic materials have a negative Poisson’s ratio (NPR), which is not often found in nature. They are metamaterials that have potential applications in many engineering fields. Mechanical metamaterials are synthetically designed structures with unusual mechanical properties. These mechanical properties are dependent on the properties of the matrix structure. They have the following special characteristics, i.e., improved shear modulus, increased energy absorption, and intensive fracture toughness. Non-auxetic materials compress transversely when they are stretched. The system naturally is inclined to keep its density constant. The transversal compression increases the density to balance the loss in the longitudinal direction. This study proposes to improve the crushing performance of hybrid auxetic materials. The re-entrant honeycomb structure has been combined with a star honeycomb, an S-shaped unit cell, a double arrowhead, and a structurally hexagonal re-entrant honeycomb by 9 X 9 cells, i.e., the number of cells is 9 in the lateral direction and 9 in the vertical direction. The Finite Element (FE) and experimental methods have been used to determine the compression behavior of the developed hybrid auxetic structures. The FE models have been developed by using Abaqus software. The specimens made of polymer plastic materials have been 3D printed and subjected to compression loading. The results are compared in terms of specific energy absorption and strength. This paper describes the quasi-static crushing behavior of two types of hybrid lattice structures (auxetic + auxetic and auxetic + non-auxetic). The results show that the developed hybrid structures can be useful to control collapse mechanisms and present larger energy absorption compared to conventional re-entrant auxetic structures.

Keywords: auxetic materials, compressive behavior, metamaterials, negative Poisson’s ratio

Procedia PDF Downloads 99
126 Retrospective/Prospective Analysis of Guideline Implementation and Transfusion Rates

Authors: B. Kenny

Abstract:

The complications associated with transfusions are well documented, with the serious hazards of transfusion (SHOT) reporting system continuing to report deaths and serious morbidity due to the transfusion of allogenic blood. Many different sources including the TRICC trial, NHMRC and Cochrane recommending similar transfusion triggers/guidelines. Recent studies found the rate of infection (deep infection, wound infection, chest infection, urinary tract infection, and others) were purely a dose response relationship, increasing the Relative Risk by 3.44. It was also noted that each transfused patient stayed in hospital for one additional day. We hypothesise that providing an approved/standardised, guideline with a graphical summary of decision pathways for anaemic patients will reduce unnecessary transfusions. We retrospectively assessed patients undergoing primary knee or hip arthroplasties over a 4 year period, 1459 patients. Of these, 339 (23.24%) patients received allogenic blood transfusions and 858 units of blood were transfused, 9.14% of patients transfused had haemoglobin levels above 100 g/L, 7.67% of patients were transfused without knowing the haemoglobin level, 24 hours prior to transfusion initiation and 4.5% had possible transfusion reactions. Overall, 17% of allogenic transfusions topatients admitted to the Orthopaedic department within a 4 year period were outside NHMRC and Cochrane guidelines/recommendations. If our transfusion frequency is compared with that of other authors/hospitals, transfusion rates are consistently being high. We subsequently implemented a simple guideline for transfusion initiation. This guideline was then assessed. We found the transfusion rate post transfusion implementation to be significantly lower, without increase in patient morbidity or mortalitiy, p <0.001). Transfusion rates and patient outcome can be optimized by a simple graphical aid for decision making.

Keywords: transfusion, morbidity, mortality, neck of femur, fracture, arthroplasty, rehabilitation

Procedia PDF Downloads 242
125 Non-Destructive Testing of Carbon Fiber Reinforced Plastic by Infrared Thermography Methods

Authors: W. Swiderski

Abstract:

Composite materials are one answer to the growing demand for materials with better parameters of construction and exploitation. Composite materials also permit conscious shaping of desirable properties to increase the extent of reach in the case of metals, ceramics or polymers. In recent years, composite materials have been used widely in aerospace, energy, transportation, medicine, etc. Fiber-reinforced composites including carbon fiber, glass fiber and aramid fiber have become a major structural material. The typical defect during manufacture and operation is delamination damage of layered composites. When delamination damage of the composites spreads, it may lead to a composite fracture. One of the many methods used in non-destructive testing of composites is active infrared thermography. In active thermography, it is necessary to deliver energy to the examined sample in order to obtain significant temperature differences indicating the presence of subsurface anomalies. To detect possible defects in composite materials, different methods of thermal stimulation can be applied to the tested material, these include heating lamps, lasers, eddy currents, microwaves or ultrasounds. The use of a suitable source of thermal stimulation on the test material can have a decisive influence on the detection or failure to detect defects. Samples of multilayer structure carbon composites were prepared with deliberately introduced defects for comparative purposes. Very thin defects of different sizes and shapes made of Teflon or copper having a thickness of 0.1 mm were screened. Non-destructive testing was carried out using the following sources of thermal stimulation, heating lamp, flash lamp, ultrasound and eddy currents. The results are reported in the paper.

Keywords: Non-destructive testing, IR thermography, composite material, thermal stimulation

Procedia PDF Downloads 259
124 Microstructure Analysis of TI-6AL-4V Friction Stir Welded Joints

Authors: P. Leo, E. Cerri, L. Fratini, G. Buffa

Abstract:

The Friction Stir Welding process uses an inert rotating mandrel and a force on the mandrel normal to the plane of the sheets to generate the frictional heat. The heat and the stirring action of the mandrel create a bond between the two sheets without melting the base metal. As matter of fact, the use of a solid state welding process limits the insurgence of defects, due to the presence of gas in melting bath, and avoids the negative effects of materials metallurgical transformation strictly connected with the change of phase. The industrial importance of Ti-6Al-4V alloy is well known. It provides an exceptional good balance of strength, ductility, fatigue and fracture properties together with good corrosion resistance and good metallurgical stability. In this paper, the authors analyze the microstructure of friction stir welded joints of Ti-6Al-4V processed at the same travel speed (35 mm/min) but at different rotation speeds (300-500 rpm). The microstructure of base material (BM), as result from both optical microscope and scanning electron microscope analysis is not homogenous. It is characterized by distorted α/β lamellar microstructure together with smashed zone of fragmented β layer and β retained grain boundary phase. The BM has been welded in the-as received state, without any previous heat treatment. Even the microstructure of the transverse and longitudinal sections of joints is not homogeneous. Close to the top of weld cross sections a much finer microstructure than the initial condition has been observed, while in the center of the joints the microstructure is less refined. Along longitudinal sections, the microstructure is characterized by equiaxed grains and lamellae. Both the length and area fraction of lamellas increases with distance from longitudinal axis. The hardness of joints is higher than that of BM. As the process temperature increases the average microhardness slightly decreases.

Keywords: friction stir welding, microhardness, microstructure, Ti-6Al-4V

Procedia PDF Downloads 381
123 Reliability and Validity of a Portable Inertial Sensor and Pressure Mat System for Measuring Dynamic Balance Parameters during Stepping

Authors: Emily Rowe

Abstract:

Introduction: Balance assessments can be used to help evaluate a person’s risk of falls, determine causes of balance deficits and inform intervention decisions. It is widely accepted that instrumented quantitative analysis can be more reliable and specific than semi-qualitative ordinal scales or itemised scoring methods. However, the uptake of quantitative methods is hindered by expense, lack of portability, and set-up requirements. During stepping, foot placement is actively coordinated with the body centre of mass (COM) kinematics during pre-initiation. Based on this, the potential to use COM velocity just prior to foot off and foot placement error as an outcome measure of dynamic balance is currently being explored using complex 3D motion capture. Inertial sensors and pressure mats might be more practical technologies for measuring these parameters in clinical settings. Objective: The aim of this study was to test the criterion validity and test-retest reliability of a synchronised inertial sensor and pressure mat-based approach to measure foot placement error and COM velocity while stepping. Methods: Trials were held with 15 healthy participants who each attended for two sessions. The trial task was to step onto one of 4 targets (2 for each foot) multiple times in a random, unpredictable order. The stepping target was cued using an auditory prompt and electroluminescent panel illumination. Data was collected using 3D motion capture and a combined inertial sensor-pressure mat system simultaneously in both sessions. To assess the reliability of each system, ICC estimates and their 95% confident intervals were calculated based on a mean-rating (k = 2), absolute-agreement, 2-way mixed-effects model. To test the criterion validity of the combined inertial sensor-pressure mat system against the motion capture system multi-factorial two-way repeated measures ANOVAs were carried out. Results: It was found that foot placement error was not reliably measured between sessions by either system (ICC 95% CIs; motion capture: 0 to >0.87 and pressure mat: <0.53 to >0.90). This could be due to genuine within-subject variability given the nature of the stepping task and brings into question the suitability of average foot placement error as an outcome measure. Additionally, results suggest the pressure mat is not a valid measure of this parameter since it was statistically significantly different from and much less precise than the motion capture system (p=0.003). The inertial sensor was found to be a moderately reliable (ICC 95% CIs >0.46 to >0.95) but not valid measure for anteroposterior and mediolateral COM velocities (AP velocity: p=0.000, ML velocity target 1 to 4: p=0.734, 0.001, 0.000 & 0.376). However, it is thought that with further development, the COM velocity measure validity could be improved. Possible options which could be investigated include whether there is an effect of inertial sensor placement with respect to pelvic marker placement or implementing more complex methods of data processing to manage inherent accelerometer and gyroscope limitations. Conclusion: The pressure mat is not a suitable alternative for measuring foot placement errors. The inertial sensors have the potential for measuring COM velocity; however, further development work is needed.

Keywords: dynamic balance, inertial sensors, portable, pressure mat, reliability, stepping, validity, wearables

Procedia PDF Downloads 153
122 Effect of Thermal Aging on Low Cycle Fatigue of Alloy 690

Authors: Kushal Gowda Jayaram, Joseph Huret, Jonathan Quibel, Walter-John Chitty, Gilbert Henaff

Abstract:

Thermal aging is one of the concerns for the long-term operation of nuclear power plants. Indeed, components in the primary circuit undergo thermal aging while exposed to the chemically active environment of Pressurized Water Reactors (PWRs) over time. Among the materials used in the reactor components, Alloy 690 can be found in some critical components for nuclear safety. Despite its importance, research on the effect of thermal aging on the microstructural changes and low cycle fatigue (LCF) behavior of Alloy 690 remains limited. This study aims to assess the impact of thermal aging on the fatigue life of Alloy 690. The as-received sample underwent aging at 420°C for 4000 hours, representing the equivalent aging of 60 years in reactor working conditions. First, the characterization of the area and density of intergranular and intragranular precipitates was performed to understand the microstructural changes in the aged specimen. Then, low cycle fatigue tests were conducted on the as received and aged samples at varying strain amplitudes. To investigate the influence of thermal aging on the fatigue behavior of Alloy 690, fracture surfaces were analyzed to estimate fatigue crack growth rates based on striation spacing measurements. Additionally, the axially cut fractured samples have undergone analysis using Electron Backscatter Diffraction (EBSD) to understand the effect of aging on strain localization near the crack path. Results indicate that while the characterization of the area and density of intergranular precipitates in the aged specimen (for 2000 hours, approximately 30 years) showed no significant changes, there was a slight increase in the area and density of intragranular precipitates under the same conditions.

Keywords: alloy 690, thermal aging, low cycle fatigue, precipitates

Procedia PDF Downloads 40
121 Study on the Fabrication and Mechanical Characterization of Pineapple Fiber-Reinforced Unsaturated Polyester Resin Based Composites: Effect of Gamma Irradiation

Authors: Kamrun N. Keya, Nasrin A. Kona, Ruhul A. Khan

Abstract:

Pineapple leaf fiber (PALF) reinforced polypropylene (PP) based composites were fabricated by a conventional compression molding technique. In this investigation, PALF composites were manufactured using different percentages of fiber, which were varying from 25-50% on the total weight of the composites. To fabricate the PALF/PP composites, untreated and treated fibers were selected. A systematic study was done to observe the physical, mechanical and interfacial behavior of the composites. In this study, mechanical properties of the composites such as tensile, impact and bending properties were observed precisely. It was found that 45wt% of fiber composites showed better mechanical properties than others. Maximum tensile strength (TS) and bending strength (BS) was observed, 65 MPa and 50 MPa respectively, whereas the highest tensile modulus (TM) and bending modulus (BM) was examined, 1.7 GPa and 0.85 GPa respectively. The PALF/PP based composites were treated with irradiated under gamma radiation (the source strength 50 kCi Cobalt-60) of various doses (2.5 kGy to 10 kGy). The effect of gamma radiation on the composites was also investigated, and it found that the effect of 5.0 kGy (i.e. units for radiation measurement is 'gray', kGy=kilogray ) gamma dose showed better mechanical properties than other doses. The values of TS, BS, TM, and BM of the irradiated (5.0 kGy) composites were found to improve by 19%, 23%, 17% and 25 % over non-irradiated composites. After flexural testing, fracture sides of the untreated and treated both composites were studied by scanning electron microscope (SEM). SEM results of the treated PALF/PP based composites showed better fiber-matrix adhesion and interfacial bonding than untreated PALF/PP based composites. Water uptake and soil degradation tests of untreated and treated composites were also investigated.

Keywords: PALF, polypropylene, compression molding technique, gamma radiation, mechanical properties, scanning electron microscope

Procedia PDF Downloads 151
120 Negative Pressure Wound Therapy in Complex Injuries of the Limbs

Authors: Mihail Nagea, Olivera Lupescu, Nicolae Ciurea, Alexandru Dimitriu, Alina Grosu

Abstract:

Introduction: As severe open injuries are more and more frequent in modern traumatology, threatening not only the integrity of the affected limb but even the life of the patients, new methods desired to cope with the consequences of these traumas were described. Vacuum therapy is one such method which has been described as enhancing healing in trauma with extensive soft-tissue injuries, included those with septic complications. Material and methods: Authors prospectively analyze 15 patients with severe lower limb trauma with MESS less than 6, with considerable soft tissue loss following initial debridement and fracture fixation. The patients needed serial debridements and vacuum therapy was applied after delayed healing due to initial severity of the trauma, for an average period of 12 days (7 - 23 days).In 7 cases vacuum therapy was applied for septic complications. Results: Within the study group, there were no local complications; secondary debridements were performed for all the patients and vacuum system was re-installed after these debridements. No amputations were needed. Medical records were reviewed in order to compare the outcome of the patients: the hospital stay, anti-microbial therapy, time to healing of the bone and soft tissues (there is no standard group to be compared with) and the result showed considerable improvements in the outcome of the patients. Conclusion: Vacuum therapy improves healing of the soft tissues, including those infected; hospital stay and the number of secondary necessary procedures are reduced. Therefore it is considered a valuable support in treating trauma of the limbs with severe soft tissue injuries.

Keywords: complex injuries, negative pressure, open fractures, wound therapy

Procedia PDF Downloads 295
119 Fabrication and Characterization of Ceramic Matrix Composite

Authors: Yahya Asanoglu, Celaletdin Ergun

Abstract:

Ceramic-matrix composites (CMC) have significant prominence in various engineering applications because of their heat resistance associated with an ability to withstand the brittle type of catastrophic failure. In this study, specific raw materials have been chosen for the purpose of having suitable CMC material for high-temperature dielectric applications. CMC material will be manufactured through the polymer infiltration and pyrolysis (PIP) method. During the manufacturing process, vacuum infiltration and autoclave will be applied so as to decrease porosity and obtain higher mechanical properties, although this advantage leads to a decrease in the electrical performance of the material. Time and temperature adjustment in pyrolysis parameters provide a significant difference in the properties of the resulting material. The mechanical and thermal properties will be investigated in addition to the measurement of dielectric constant and tangent loss values within the spectrum of Ku-band (12 to 18 GHz). Also, XRD, TGA/PTA analyses will be employed to prove the transition of precursor to ceramic phases and to detect critical transition temperatures. Additionally, SEM analysis on the fracture surfaces will be performed to see failure mechanism whether there is fiber pull-out, crack deflection and others which lead to ductility and toughness in the material. In this research, the cost-effectiveness and applicability of the PIP method will be proven in the manufacture of CMC materials while optimization of pyrolysis time, temperature and cycle for specific materials is detected by experiment. Also, several resins will be shown to be a potential raw material for CMC radome and antenna applications. This research will be distinguished from previous related papers due to the fact that in this research, the combination of different precursors and fabrics will be experimented with to specify the unique cons and pros of each combination. In this way, this is an experimental sum of previous works with unique PIP parameters and a guide to the manufacture of CMC radome and antenna.

Keywords: CMC, PIP, precursor, quartz

Procedia PDF Downloads 160
118 Exploration of Industrial Symbiosis Opportunities with an Energy Perspective

Authors: Selman Cagman

Abstract:

A detailed analysis is made within an organized industrial zone (OIZ) that has 1165 production facilities such as manufacturing of furniture, fabricated metal products (machinery and equipment), food products, plastic and rubber products, machinery and equipment, non-metallic mineral products, electrical equipment, textile products, and manufacture of wood and cork products. In this OIZ, a field study is done by choosing some facilities that can represent the whole OIZ sectoral distribution. In this manner, there are 207 facilities included to the site visit, and there is a 17 questioned survey carried out with each of them to assess their inputs, outputs, and waste amounts during manufacturing processes. The survey result identify that MDF/Particleboard and chipboard particles, textile, food, foam rubber, sludge (treatment sludge, phosphate-paint sludge, etc.), plastic, paper and packaging, scrap metal (aluminum shavings, steel shavings, iron scrap, profile scrap, etc.), slag (coal slag), ceramic fracture, ash from the fluidized bed are the wastes come from these facilities. As a result, there are 5 industrial symbiosis projects established with this study. One of the projects is a 2.840 kW capacity Integrated Biomass Based Waste Incineration-Energy Production Facility running on 35.000 tons/year of MDF particles and chipboard waste. Another project is a biogas plant with 225 tons/year whey, 100 tons/year of sesame husk, 40 tons/year of burnt wafer dough, and 2.000 tons/year biscuit waste. These two plants investment costs and operational costs are given in detail. The payback time of the 2.840 kW plant is almost 4 years and the biogas plant is around 6 years.

Keywords: industrial symbiosis, energy, biogas, waste to incineration

Procedia PDF Downloads 107
117 The Evaluation for Interfacial Adhesion between SOFC and Metal Adhesive in the High Temperature Environment

Authors: Sang Koo Jeon, Seung Hoon Nahm, Oh Heon Kwon

Abstract:

The unit cell of solid oxide fuel cell (SOFC) must be stacked as several layers type to obtain the high power. The most of researcher have concerned about the performance of stacked SOFC rather than the structural stability of stacked SOFC and especially interested how to design for reducing the electrical loss and improving the high efficiency. Consequently, the stacked SOFC able to produce the electrical high power and related parts like as manifold, gas seal, bipolar plate were developed to optimize the stack design. However, the unit cell of SOFC was just layered on the interconnector without the adhesion and the hydrogen and oxygen were injected to the interfacial layer in the high temperature. On the operating condition, the interfacial layer can be the one of the weak point in the stacked SOFC. Therefore the evaluation of the structural safety for the failure is essentially needed. In this study, interfacial adhesion between SOFC and metal adhesive was estimated in the high temperature environment. The metal adhesive was used to strongly connect the unit cell of SOFC with interconnector and provide the electrical conductivity between them. The four point bending test was performed to measure the interfacial adhesion. The unit cell of SOFC and SiO2 wafer were diced and then attached by metal adhesive. The SiO2 wafer had the center notch to initiate a crack from the tip of the notch. The modified stereomicroscope combined with the CCD camera and system for measuring the length was used to observe the fracture behavior. Additionally, the interfacial adhesion was evaluated in the high temperature condition because the metal adhesive was affected by high temperature. Also the specimen was exposed in the furnace during several hours and then the interfacial adhesion was evaluated. Finally, the interfacial adhesion energy was quantitatively determined and compared in the each condition.

Keywords: solid oxide fuel cell (SOFC), metal adhesive, adhesion, high temperature

Procedia PDF Downloads 521
116 Egg Yolk Peptide Stimulated Osteogenic Gene Expression

Authors: Hye Kyung Kim, Myung-Gyou Kim, Kang-Hyun Leem

Abstract:

Postmenopausal osteoporosis is characterized by low bone density which leads to increased bone fragility and greater susceptibility to fracture. Current treatments for osteoporosis are dominated by drugs that inhibit bone resorption although they also suppress bone formation that may contribute to pathogenesis of osteonecrosis. To restore the extensive bone loss, there is a great need for anabolic treatments that induce osteoblasts to build new bone. Pre-osteoblastic cells produce proteins of the extra-cellular matrix, including type I collagen at first, and then to successively produce alkaline phosphatase (ALP) and osteocalcin during differentiation to osteoblasts. Finally, osteoblasts deposit calcium. Present study investigated the effects of egg yolk peptide (EYP) on osteogenic activities and bone matrix gene expressions in human osteoblastic MG-63 cells. The effects of EYP on cell proliferation, alkaline phosphatase (ALP) activity, collagen synthesis, and mineralization were measured. The expression of osteogenic genes including COL1A1 (collagen, type I, alpha 1), ALP, BGLAP (osteocalcin), and SPP1 (secreted phosphoprotein 1, osteopontin) were measured by quantitative realtime PCR. EYP dose-dependently increased MG-63 cell proliferation, ALP activity, collagen synthesis, and calcium deposition. Furthermore, COL1A1, ALP, and SPP1 gene expressions were increased by EYP treatment. Present study suggested that EYP treatment enhanced osteogenic activities and increased bone matrix osteogenicgenes. These results could provide a mechanistic explanation for the bone-strengthening effects of EYP.

Keywords: egg yolk peptide, osteoblastic MG-63 cells, alkaline phosphatase, collagen synthesis, osteogenic genes, COL1A1, osteocalcin, osteopontin

Procedia PDF Downloads 388
115 Development and Characterization of Sandwich Bio-Composites Based on Short Alfa Fiber and Jute Fabric

Authors: Amine Rezzoug, Selsabil Rokia Laraba, Mourad Ancer, Said Abdi

Abstract:

Composite materials are taking center stage in different fields thanks to their mechanical characteristics and their ease of preparation. Environmental constraints have led to the development of composite with natural reinforcements. The sandwich structure has the advantage to have good flexural proprieties for low density, which is why it was chosen in this work. The development of these materials is related to an energy saving strategy and environmental protection. The present work refers to the study of the development and characterization of sandwiches composites based on hybrids laminates with natural reinforcements (Alfa and Jute), a metal fabric was introduced into composite in order to have a compromise between weight and properties. We use different configurations of reinforcements (jute, metallic fabric) to develop laminates in order to use them as thin facings for sandwiches materials. While the core was an epoxy matrix reinforced with Alfa short fibers, a chemical treatment sodium hydroxide was cared to improve the adhesion of the Alfa fibers. The mechanical characterization of our materials was made by the tensile and bending test, to highlight the influence of jute and Alfa. After testing, the fracture surfaces are observed by scanning electron microscopy (SEM). Optical microscopy allowed us to calculate the degree of porosity and to observe the morphology of the individual layers. Laminates based on jute fabric have shown better results in tensile test as well as to bending, compared to those of the metallic fabric (100%, 65%). Sandwich Panels were also characterized in terms of bending test. Results we had provide, shows that this composite has sufficient properties for possible replacing conventional composite materials by considering the environmental factors.

Keywords: bending test, bio-composites, sandwiches, tensile test

Procedia PDF Downloads 435
114 Effects of Pulsed Electromagnetic and Static Magnetic Fields on Musculoskeletal Low Back Pain: A Systematic Review Approach

Authors: Mohammad Javaherian, Siamak Bashardoust Tajali, Monavvar Hadizadeh

Abstract:

Objective: This systematic review study was conducted to evaluate the effects of Pulsed Electromagnetic (PEMF) and Static Magnetic Fields (SMG) on pain relief and functional improvement in patients with musculoskeletal Low Back Pain (LBP). Methods: Seven electronic databases were searched by two researchers independently to identify the published Randomized Controlled Trials (RCTs) on the efficacy of pulsed electromagnetic, static magnetic, and therapeutic nuclear magnetic fields. The identified databases for systematic search were Ovid Medline®, Ovid Cochrane RCTs and Reviews, PubMed, Web of Science, Cochrane Library, CINAHL, and EMBASE from 1968 to February 2016. The relevant keywords were selected by Mesh. After initial search and finding relevant manuscripts, all references in selected studies were searched to identify second hand possible manuscripts. The published RCTs in English would be included to the study if they reported changes on pain and/or functional disability following application of magnetic fields on chronic musculoskeletal low back pain. All studies with surgical patients, patients with pelvic pain, and combination of other treatment techniques such as acupuncture or diathermy were excluded. The identified studies were critically appraised and the data were extracted independently by two raters (M.J and S.B.T). Probable disagreements were resolved through discussion between raters. Results: In total, 1505 abstracts were found following the initial electronic search. The abstracts were reviewed to identify potentially relevant manuscripts. Seventeen possibly appropriate studies were retrieved in full-text of which 48 were excluded after reviewing their full-texts. Ten selected articles were categorized into three subgroups: PEMF (6 articles), SMF (3 articles), and therapeutic nuclear magnetic fields (tNMF) (1 article). Since one study evaluated tNMF, we had to exclude it. In the PEMF group, one study of acute LBP did not show significant positive results and the majority of the other five studies on Chronic Low Back Pain (CLBP) indicated its efficacy on pain relief and functional improvement, but one study with the lowest sessions (6 sessions during 2 weeks) did not report a significant difference between treatment and control groups. In the SMF subgroup, two articles reported near significant pain reduction without any functional improvement although more studies are needed. Conclusion: The PEMFs with a strength of 5 to 150 G or 0.1 to 0.3 G and a frequency of 5 to 64 Hz or sweep 7 to 7KHz can be considered as an effective modality in pain relief and functional improvement in patients with chronic low back pain, but there is not enough evidence to confirm their effectiveness in acute low back pain. To achieve the appropriate effectiveness, it is suggested to perform this treatment modality 20 minutes per day for at least 9 sessions. SMFs have not been reported to be substantially effective in decreasing pain or improving the function in chronic low back pain. More studies are necessary to achieve more reliable results.

Keywords: pulsed electromagnetic field, static magnetic field, magnetotherapy, low back pain

Procedia PDF Downloads 205
113 The Role of Uterine Artery Embolization in the Management of Postpartum Hemorrhage

Authors: Chee Wai Ku, Pui See Chin

Abstract:

As an emerging alternative to hysterectomy, uterine artery embolization (UAE) has been widely used in the management of fibroids and in controlling postpartum hemorrhage (PPH) unresponsive to other therapies. Research has shown UAE to be a safe, minimally invasive procedure with few complications and minimal effects on future fertility. We present two cases highlighting the use of UAE in preventing PPH in a patient with a large fibroid at the time of cesarean section and in the treatment of secondary PPH refractory to other therapies in another patient. We present a 36-year primiparous woman who booked at 18+6 weeks gestation with a 13.7 cm subserosal fibroid at the lower anterior wall of the uterus near the cervix and a 10.8 cm subserosal fibroid in the left wall. Prophylactic internal iliac artery occlusion balloons were placed prior to the planned classical midline cesarean section. The balloons were inflated once the baby was delivered. Bilateral uterine arteries were embolized subsequently. The estimated blood loss (EBL) was 400 mls and hemoglobin (Hb) remained stable at 10 g/DL. Ultrasound scan 2 years postnatally showed stable uterine fibroids 10.4 and 7.1 cm, which was significantly smaller than before. We present the second case of a 40-year-old G2P1 with a previous cesarean section for failure to progress. There were no antenatal problems, and the placenta was not previa. She presented with term labour and underwent an emergency cesarean section for failed vaginal birth after cesarean. Intraoperatively extensive adhesions were noted with bladder drawn high, and EBL was 300 mls. Postpartum recovery was uneventful. She presented with secondary PPH 3 weeks later complicated by hypovolemic shock. She underwent an emergency examination under anesthesia and evacuation of the uterus, with EBL 2500mls. Histology showed decidua with chronic inflammation. She was discharged well with no further PPH. She subsequently returned one week later for secondary PPH. Bedside ultrasound showed that the endometrium was thin with no evidence of retained products of conception. Uterotonics were administered, and examination under anesthesia was performed, with uterine Bakri balloon and vaginal pack insertion after. EBL was 1000 mls. There was no definite cause of PPH with no uterine atony or products of conception. To evaluate a potential cause, pelvic angiogram and super selective left uterine arteriogram was performed which showed profuse contrast extravasation and acute bleeding from the left uterine artery. Superselective embolization of the left uterine artery was performed. No gross contrast extravasation from the right uterine artery was seen. These two cases demonstrated the superior efficacy of UAE. Firstly, the prophylactic use of intra-arterial balloon catheters in pregnant patients with large fibroids, and secondly, in the diagnosis and management of secondary PPH refractory to uterotonics and uterine tamponade. In both cases, the need for laparotomy hysterectomy was avoided, resulting in the preservation of future fertility. UAE should be a consideration for hemodynamically stable patients in centres with access to interventional radiology.

Keywords: fertility preservation, secondary postpartum hemorrhage, uterine embolization, uterine fibroids

Procedia PDF Downloads 187
112 A Novel Study Contrasting Traditional Autopsy with Post-Mortem Computed Tomography in Falls Leading to Death

Authors: Balaji Devanathan, Gokul G., Abilash S., Abhishek Yadav, Sudhir K. Gupta

Abstract:

Background: As an alternative to the traditional autopsy, a virtual autopsy is carried out using scanning and imaging technologies, mainly post-mortem computed tomography (PMCT). This facility aims to supplement traditional autopsy results and reduce or eliminate internal dissection in subsequent autopsies. For emotional and religious reasons, the deceased's relatives have historically disapproved such interior dissection. The non-invasive, objective, and preservative PMCT is what friends and family would rather have than a traditional autopsy. Additionally, it aids in the examination of the technologies and the benefits and drawbacks of each, demonstrating the significance of contemporary imaging in the field of forensic medicine. Results: One hundred falls resulting in fatalities was analysed by the writers. Before the autopsy, each case underwent a PMCT examination using a 16-slice Multi-Slice CT spiral scanner. By using specialised software, MPR and VR reconstructions were carried out following the capture of the raw images. The accurate detection of fractures in the skull, face bones, clavicle, scapula, and vertebra was better observed in comparison to a routine autopsy. The interpretation of pneumothorax, Pneumoperitoneum, pneumocephalus, and hemosiuns are much enhanced by PMCT than traditional autopsy. Conclusion. It is useful to visualise the skeletal damage in fall from height cases using a virtual autopsy based on PMCT. So, the ideal tool in traumatising patients is a virtual autopsy based on PMCT scans. When assessing trauma victims, PMCT should be viewed as an additional helpful tool to traditional autopsy. This is because it can identify additional bone fractures in body parts that are challenging to examine during autopsy, such as posterior regions, which helps the pathologist reconstruct the victim's life and determine the cause of death.

Keywords: PMCT, fall from height, autopsy, fracture

Procedia PDF Downloads 41
111 Adhesive Bonded Joints Characterization and Crack Propagation in Composite Materials under Cyclic Impact Fatigue and Constant Amplitude Fatigue Loadings

Authors: Andres Bautista, Alicia Porras, Juan P. Casas, Maribel Silva

Abstract:

The Colombian aeronautical industry has stimulated research in the mechanical behavior of materials under different loading conditions aircrafts are generally exposed during its operation. The Calima T-90 is the first military aircraft built in the country, used for primary flight training of Colombian Air Force Pilots, therefore, it may be exposed to adverse operating situations such as hard landings which cause impact loads on the aircraft that might produce the impact fatigue phenomenon. The Calima T-90 structure is mainly manufactured by composites materials generating assemblies and subassemblies of different components of it. The main method of bonding these components is by using adhesive joints. Each type of adhesive bond must be studied on its own since its performance depends on the conditions of the manufacturing process and operating characteristics. This study aims to characterize the typical adhesive joints of the aircraft under usual loads. To this purpose, the evaluation of the effect of adhesive thickness on the mechanical performance of the joint under quasi-static loading conditions, constant amplitude fatigue and cyclic impact fatigue using single lap-joint specimens will be performed. Additionally, using a double cantilever beam specimen, the influence of the thickness of the adhesive on the crack growth rate for mode I delamination failure, as a function of the critical energy release rate will be determined. Finally, an analysis of the fracture surface of the test specimens considering the mechanical interaction between the substrate (composite) and the adhesive, provide insights into the magnitude of the damage, the type of failure mechanism that occurs and its correlation with the way crack propagates under the proposed loading conditions.

Keywords: adhesive, composites, crack propagation, fatigue

Procedia PDF Downloads 204
110 Operative versus Non-Operative Treatment of Scaphoid Non-Union in Children: A Case Presentation and Review of the Literature

Authors: Ilja Käch, Abdul R. Jandali, Nadja Zechmann-Müller

Abstract:

Introduction: We discuss the treatment of two young male patients suffering from scaphoid non-union after a traumatic scaphoid fracture. The currently propagated techniques for treating a scaphoid non-union in children are either the operative reconstruction of the scaphoid or the conservative treatment with splinting in a scaphoid cast. Cases: In the first case, we operated on a 13 years old male patient with a posttraumatic scaphoid non-union in the middle third with a humpback deformity. We resected the middle third of the scaphoid and grafted the defect with an iliac crest bone, and the DISI-Deformity was reduced. Fixation was performed with K-Wires and immobilisation in a scaphoid cast. In the second case a 13 years old male patient also with a posttraumatic scaphoid non-union in the middle third and humpback deformity, DISI-deformity, was treated conservatively. Immobilisation in a scaphoid cast for four months was performed. Results: Operative: One year postoperatively the patient achieved a painless free arc of motion. Flexion/Extension 70/0/60°, Radial-/Ulnarduction 30/0/30° and Pro-/Supination 90/0/90°. The computer tomogram showed complete consolidation and bony fusion of the iliac crest bone. Conservative: Six to eight months after conservative treatment the patient demonstrated painless motion and AROM Flexion/Extension 80/0/80°, Radial-/Ulnarduction and Pro-/Supination in maximum range. Complete consolidation in the computer tomogram with persistent humpback- and DISI deformity. Conclusion: In the literature, both techniques are described, either the operative scaphoid reconstruction or the conservative treatment with splinting. In our cases, both the operative and conservative treatments showed comparable good results. However, the humpback- and DISI deformity can only be addressed with a surgical approach.

Keywords: scaphoid, non-union, trauma, operative vs. non operative

Procedia PDF Downloads 77
109 Surface Deformation Studies in South of Johor Using the Integration of InSAR and Resistivity Methods

Authors: Sirajo Abubakar, Ismail Ahmad Abir, Muhammad Sabiu Bala, Muhammad Mustapha Adejo, Aravind Shanmugaveloo

Abstract:

Over the years, land subsidence has been a serious threat mostly to urban areas. Land subsidence is the sudden sinking or gradual downward settling of the ground’s surface with little or no horizontal motion. In most areas, land subsidence is a slow process that covers a large area; therefore, it is sometimes left unnoticed. South of Johor is the area of interest for this project because it is going through rapid urbanization. The objective of this research is to evaluate and identify potential deformations in the south of Johor using integrated remote sensing and 2D resistivity methods. Synthetic aperture radar interferometry (InSAR) which is a remote sensing technique has the potential to map coherent displacements at centimeter to millimeter resolutions. Persistent scatterer interferometry (PSI) stacking technique was applied to Sentinel-1 data to detect the earth deformation in the study area. A dipole-dipole configuration resistivity profiling was conducted in three areas to determine the subsurface features in that area. This subsurface features interpreted were then correlated with the remote sensing technique to predict the possible causes of subsidence and uplifts in the south of Johor. Based on the results obtained, West Johor Bahru (0.63mm/year) and Ulu Tiram (1.61mm/year) are going through uplift due to possible geological uplift. On the other end, East Johor Bahru (-0.26mm/year) and Senai (-1.16mm/year) undergo subsidence due to possible fracture and granitic boulders loading. Land subsidence must be taken seriously as it can cause serious damages to infrastructures and human life. Monitoring land subsidence and taking preventive actions must be done to prevent any disasters.

Keywords: interferometric synthetic aperture radar, persistent scatter, minimum spanning tree, resistivity, subsidence

Procedia PDF Downloads 147
108 Chronic Left Sciatic Nerve Injury and Subsequent Complications Following Delayed Hip Dislocation Treatment in a 34-Year Old Male: A Case Report

Authors: Hamida Memon, Muhammad Sanan

Abstract:

A 34-year-old male with no prior health issues presented with a wound in his left leg exhibiting active pus discharge, intense inflammation, pain radiating from the buttocks to the knee, foot drop, and skin darkening. Four years prior, he sustained an untreated dislocation of the hip joint and acetabulum from a road traffic accident. Initial nerve conduction studies (NCS) and electromyography (EMG) revealed severe axonotomesis of the left sciatic nerve and reduced compound muscle action potential in the left common peroneal nerve. Despite normal venous flow, edema and cellulitis were noted. Follow-up NCS/EMG in 2022 showed improvement, but in 2023, the patient experienced recurrent infection and underwent surgical intervention with tissue culture. Postoperative care included antibiotics and pain management. NCS/EMG in 2024 indicated decreased nerve amplitudes and conduction velocities, consistent with moderate axonotmesis and ongoing recovery, alongside incidental right S1 radiculopathy. General lab tests and abdominal imaging were normal. The patient was treated with Pregabalin and Neurobion for neuropathic pain and nerve support and is currently under observation by a tertiary sector hospital for treatment. This case underscores the critical importance of prompt treatment for hip dislocations to prevent long-term complications such as neuropathy and avascular necrosis. Delays in treatment significantly increase the risk of severe outcomes, highlighting the need for timely intervention. Overall, the case illustrates the challenges of managing complex nerve injuries and the importance of comprehensive care for optimal recovery.

Keywords: sciatic nerve neuropathy, hip dislocation, acetabular fracture, radiculopathy

Procedia PDF Downloads 23
107 Thermomechanical Deformation Response in Cold Sprayed SiCp/Al Composites: Strengthening, Microstructure Characterization, and Thermomechanical Properties

Authors: L. Gyansah, Yanfang Shen, Jiqiang Wang, Tianying Xiong

Abstract:

SiCₚ/ pure Al composites with different SiC fractions (20 wt %, 30 wt %, and 40 wt %) were precisely cold sprayed, followed by hot axial-compression tests at deformation temperatures of 473 K to 673 K, leading to failure of specimens through routine crack propagation in their multiphase. The plastic deformation behaviour with respect to the SiCₚ contents and the deformation temperatures were studied at strain rate 1s-1.As-sprayed and post-failure specimens were analyzed by X-ray computed tomography (XCT), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Quasi-static thermomechanical testing results revealed that compressive strength (UTS = 228 MPa and 30.4 %) was the highest in the composites that was thermomechanically compressed at 473 K compared to those of the as-sprayed, while the as-sprayed exhibited a compressive strength of 182.8 MPa related to the increment in SiC fraction. Strength—plasticity synergy was promoted by dynamic recrystallization (DRX) through strengthening and refinement of the grains. The DRX degree depends relevantly on retainment of the uniformly ultrafine SiCₚ particulates, the pinning effects of the interfaces promoted by the ultrafine grain structures (UFG), and the higher deformation temperature. Reconstructed X-ray computed tomography data revealed different crack propagation mechanisms. A single-plane shear crack with multi-laminates fracture morphology yields relatively through the as-sprayed and as-deformed at 473 K deposits, while a multiphase plane shear cracks preeminently existed in high temperature deformed deposits resulting in multiphase-interface delaminations. Three pertinent strengthening mechanisms, videlicet, SiCp dispersed strengthening, refined grain strengthening, and dislocation strengthening, existed in the gradient microstructure, and their detailed contributions to the thermomechanical properties were discussed.

Keywords: cold spraying, hot deformation, deformation temperature, thermomechancal properties, SiC/Al composite

Procedia PDF Downloads 108