Search results for: total arterial
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 8830

Search results for: total arterial

8800 Lessons Learnt from a Patient with Pseudohyperkalaemia Secondary to Polycythaemia Rubra Vera in a Neuro-ICU Patient Resulting in Dangerous Interventions: Lessons Learnt on Patient Safety Improvement

Authors: Dinoo Kirthinanda, Sujani Wijeratne

Abstract:

Pseudohyperkalaemia is a common benign in vitro phenomenon caused by the release of potassium ions (K+) from cells during specimen processing. Analysis of haemolysed blood samples for predominantly intracellular electrolytes may lead to re-investigation and potentially harmful interventions. We report a case of a 52-year male with myeloproliferative disease manifested as Polycythaemia Rubra Vera, Hypertension and hypertensive nephropathy with stage 3 chronic kidney disease admitted to Neuro-intensive care unit (NICU) with an intra-cerebral haemorrhage secondary to hypertensive bleed. His initial blood investigations showed hyperkalemia with serum K+ 6.2 mmol/L yet the bedside arterial blood gas analysis yielded K+ of 4.6 mmol/L. The patient was however given hyperkalemia regime twice based on venous electrolyte analysis. The discrepancy between the bedside electrolyte analysis using arterial blood and venous blood prompted further evaluation. The 12 lead Electrocardiogram showed U waves and sinus bradycardia corresponding to the serum K+ of 2.8 mmol/L on arterial blood gas analysis. Immediate K+ replacement ensured the patient did not develop life-threatening cardiac complications. Pseudohyperkalaemia may pose diagnostic challenges in the absence of detectable haemolysis and should be suspected in susceptible patients with normal Electrocardiogram and Glomerular Filtration Rate to avoid potentially life-threatening interventions. When in doubt, rapid analysis of arterial blood gas may be useful for accurate quantification of potassium.

Keywords: patient safety, pseudohyperkalaemia, haemolysis, myeloproliferative disorder

Procedia PDF Downloads 133
8799 Adequacy of Second-Generation Laryngeal Mask Airway during Prolonged Abdominal Surgery

Authors: Sukhee Park, Gaab Soo Kim

Abstract:

Purpose: We aimed to evaluate the adequacy of second-generation laryngeal mask airway use during prolonged abdominal surgery in respect of ventilation, oxygenation, postoperative pulmonary complications (PPC), and postoperative non-pulmonary complications on living donor kidney transplant (LDKT) surgery. Methods: In total, 257 recipients who underwent LDKT using either laryngeal mask airway-ProSeal (LMA-P) or endotracheal tube (ETT) were retrospectively analyzed. Arterial partial pressure of carbon dioxide (PaCO2 and ratio of arterial partial pressure of oxygen to fractional inspired oxygen (PFR) during surgery were compared between two groups. In addition, PPC including pulmonary aspiration and postoperative non-pulmonary complications including nausea, vomiting, hoarseness, vocal cord palsy, delirium, and atrial fibrillation were also compared. Results: PaCO2 and PFR during surgery were not significantly different between the two groups. PPC was also not significantly different between the two groups. Interestingly, the incidence of delirium was significantly lower in the LMA-P group than the ETT group (3.0% vs. 10.3%, P = 0.029). Conclusions: During prolonged abdominal surgery such as LDKT, second-generation laryngeal mask airway offers adequate ventilation and oxygenation and can be considered a suitable alternative to ETT.

Keywords: laryngeal mask airway, prolonged abdominal surgery, kidney transplantation, postoperative pulmonary complication

Procedia PDF Downloads 134
8798 Immunologically Non-Treated Vascular Xenografts in Long-Term Survival Animals

Authors: W. G. Kim, J. M. Chang, W. S. Kim

Abstract:

Immunologically non-treated and acellularized porcine xenografts were implanted as an arterial graft in goats and comparatively analyzed for the explanted grafts with gross observation, as well as light microscopy and immunohistochemistry, following the predetermined periods. For immunologically non-treated xenografts, bilateral porcine carotid arteries were harvested, and after short-term freezing at -70°C, were implanted into goats. The preparation of acellularized xenograft vessels has been performed with Nacl-SDS solution and stored at the freezer until use. The goats were randomly assigned for three periods of observation (3, 6, and 12 months after implantation), four animals were observed at each of these times. Periodic ultrasonographic examinations were performed during observation period. Following the predetermined periods, the explanted grafts were analyzed. Among 12 animals, one goat died prematurely, and a total of 22 grafts were evaluated. Gross observations revealed non-thrombotic patent smooth lumens. Microscopic examinations of the explanted grafts showed satisfactory cellular reconstruction up to the 12-month observation period. The proportions of CD3 positive T lymphocytes among inflammatory cells infiltrations were very low. In conclusion, these findings, as a whole, suggest that porcine vessel xenografts can be clinically acceptably implanted in the goats as a form of small-diameter vascular graft, regardless of the acellularized xenograft or immunologically non-treated xenograft.

Keywords: xenograft, arterial graft, long-term survival animals, immunology

Procedia PDF Downloads 327
8797 Quantification of Dispersion Effects in Arterial Spin Labelling Perfusion MRI

Authors: Rutej R. Mehta, Michael A. Chappell

Abstract:

Introduction: Arterial spin labelling (ASL) is an increasingly popular perfusion MRI technique, in which arterial blood water is magnetically labelled in the neck before flowing into the brain, providing a non-invasive measure of cerebral blood flow (CBF). The accuracy of ASL CBF measurements, however, is hampered by dispersion effects; the distortion of the ASL labelled bolus during its transit through the vasculature. In spite of this, the current recommended implementation of ASL – the white paper (Alsop et al., MRM, 73.1 (2015): 102-116) – does not account for dispersion, which leads to the introduction of errors in CBF. Given that the transport time from the labelling region to the tissue – the arterial transit time (ATT) – depends on the region of the brain and the condition of the patient, it is likely that these errors will also vary with the ATT. In this study, various dispersion models are assessed in comparison with the white paper (WP) formula for CBF quantification, enabling the errors introduced by the WP to be quantified. Additionally, this study examines the relationship between the errors associated with the WP and the ATT – and how this is influenced by dispersion. Methods: Data were simulated using the standard model for pseudo-continuous ASL, along with various dispersion models, and then quantified using the formula in the WP. The ATT was varied from 0.5s-1.3s, and the errors associated with noise artefacts were computed in order to define the concept of significant error. The instantaneous slope of the error was also computed as an indicator of the sensitivity of the error with fluctuations in ATT. Finally, a regression analysis was performed to obtain the mean error against ATT. Results: An error of 20.9% was found to be comparable to that introduced by typical measurement noise. The WP formula was shown to introduce errors exceeding 20.9% for ATTs beyond 1.25s even when dispersion effects were ignored. Using a Gaussian dispersion model, a mean error of 16% was introduced by using the WP, and a dispersion threshold of σ=0.6 was determined, beyond which the error was found to increase considerably with ATT. The mean error ranged from 44.5% to 73.5% when other physiologically plausible dispersion models were implemented, and the instantaneous slope varied from 35 to 75 as dispersion levels were varied. Conclusion: It has been shown that the WP quantification formula holds only within an ATT window of 0.5 to 1.25s, and that this window gets narrower as dispersion occurs. Provided that the dispersion levels fall below the threshold evaluated in this study, however, the WP can measure CBF with reasonable accuracy if dispersion is correctly modelled by the Gaussian model. However, substantial errors were observed with other common models for dispersion with dispersion levels similar to those that have been observed in literature.

Keywords: arterial spin labelling, dispersion, MRI, perfusion

Procedia PDF Downloads 356
8796 Non-Invasive Assessment of Peripheral Arterial Disease: Automated Ankle Brachial Index Measurement and Pulse Volume Analysis Compared to Ultrasound Duplex Scan

Authors: Jane E. A. Lewis, Paul Williams, Jane H. Davies

Abstract:

Introduction: There is, at present, a clear and recognized need to optimize the diagnosis of peripheral arterial disease (PAD), particularly in non-specialist settings such as primary care, and this arises from several key facts. Firstly, PAD is a highly prevalent condition. In 2010, it was estimated that globally, PAD affected more than 202 million people and furthermore, this prevalence is predicted to further escalate. The disease itself, although frequently asymptomatic, can cause considerable patient suffering with symptoms such as lower limb pain, ulceration, and gangrene which, in worse case scenarios, can necessitate limb amputation. A further and perhaps the most eminent consequence of PAD arises from the fact that it is a manifestation of systemic atherosclerosis and therefore is a powerful predictor of coronary heart disease and cerebrovascular disease. Objective: This cross sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (i) ankle brachial index (ABI) and (ii) pulse volume waveform (PVW) recorded by the same automated device, with the presence or absence of peripheral arterial disease (PAD) being verified by an Ultrasound Duplex Scan (UDS). Methods: Patients (n = 205) referred for lower limb arterial assessment underwent an ABI and PVW measurement using volume plethysmography followed by a UDS. Presence of PAD was recorded for ABI if < 0.9 (noted if > 1.30) if PVW was graded as 2, 3 or 4 or a hemodynamically significant stenosis > 50% with UDS. Outcome measure was agreement between measured ABI and interpretation of the PVW for PAD diagnosis, using UDS as the reference standard. Results: Sensitivity of ABI was 80%, specificity 91%, and overall accuracy 88%. Cohen’s kappa revealed good agreement between ABI and UDS (k = 0.7, p < .001). PVW sensitivity 97%, specificity 81%, overall accuracy 84%, with a good level of agreement between PVW and UDS (k = 0.67, p < .001). The combined sensitivity of ABI and PVW was 100%, specificity 76%, and overall accuracy 85% (k = 0.67, p < .001). Conclusions: Combing these two diagnostic modalities within one device provided a highly accurate method of ruling out PAD. Such a device could be utilized within the primary care environment to reduce the number of unnecessary referrals to secondary care with concomitant cost savings, reduced patient inconvenience, and prioritization of urgent PAD cases.

Keywords: ankle brachial index, peripheral arterial disease, pulse volume waveform, ultrasound duplex scan

Procedia PDF Downloads 145
8795 Implementation of Congestion Management Strategies on Arterial Roads: Case Study of Geelong

Authors: A. Das, L. Hitihamillage, S. Moridpour

Abstract:

Natural disasters are inevitable to the biodiversity. Disasters such as flood, tsunami and tornadoes could be brutal, harsh and devastating. In Australia, flooding is a major issue experienced by different parts of the country. In such crisis, delays in evacuation could decide the life and death of the people living in those regions. Congestion management could become a mammoth task if there are no steps taken before such situations. In the past to manage congestion in such circumstances, many strategies were utilised such as converting the road shoulders to extra lanes or changing the road geometry by adding more lanes. However, expansion of road to resolving congestion problems is not considered a viable option nowadays. The authorities avoid this option due to many reasons, such as lack of financial support and land space. They tend to focus their attention on optimising the current resources they possess and use traffic signals to overcome congestion problems. Traffic Signal Management strategy was considered a viable option, to alleviate congestion problems in the City of Geelong, Victoria. Arterial road with signalised intersections considered in this paper and the traffic data required for modelling collected from VicRoads. Traffic signalling software SIDRA used to model the roads, and the information gathered from VicRoads. In this paper, various signal parameters utilised to assess and improve the corridor performance to achieve the best possible Level of Services (LOS) for the arterial road.

Keywords: congestion, constraints, management, LOS

Procedia PDF Downloads 374
8794 The Effect of Body Positioning on Upper-Limb Arterial Occlusion Pressure and the Reliability of the Method during Blood Flow Restriction Training

Authors: Stefanos Karanasios, Charkleia Koutri, Maria Moutzouri, Sofia A. Xergia, Vasiliki Sakellari, George Gioftsos

Abstract:

The precise calculation of arterial occlusive pressure (AOP) is a critical step to accurately prescribe individualized pressures during blood flow restriction training (BFRT). AOP is usually measured in a supine position before training; however, previous reports suggested a significant influence in lower limb AOP across different body positions. The aim of the study was to investigate the effect of three different body positions on upper limb AOP and the reliability of the method for its standardization in clinical practice. Forty-two healthy participants (Mean age: 28.1, SD: ±7.7) underwent measurements of upper limb AOP in supine, seated, and standing positions by three blinded raters. A cuff with a manual pump and a pocket doppler ultrasound were used. A significantly higher upper limb AOP was found in seated compared with supine position (p < 0.031) and in supine compared with standing position (p < 0.031) by all raters. An excellent intraclass correlation coefficient (0.858- 0.984, p < 0.001) was found in all positions. Upper limb AOP is strongly dependent on body position changes. The appropriate measurement position should be selected to accurately calculate AOP before BFRT. The excellent inter-rater reliability and repeatability of the method suggest reliable and consistent results across repeated measurements.

Keywords: Kaatsu training, blood flow restriction training, arterial occlusion, reliability

Procedia PDF Downloads 188
8793 Limited Ventilation Efficacy of Prehospital I-Gel Insertion in Out-of-Hospital Cardiac Arrest Patients

Authors: Eunhye Cho, Hyuk-Hoon Kim, Sieun Lee, Minjung Kathy Chae

Abstract:

Introduction: I-gel is a commonly used supraglottic advanced airway device in prehospital out-of-hospital cardiac arrest (OHCA) allowing for minimal interruption of continuous chest compression. However, previous studies have shown that prehospital supraglottic airway had inferior neurologic outcomes and survival compared to no advanced prehospital airway with conventional bag mask ventilation. We hypothesize that continuous compression with i-gel as an advanced airway may cause insufficient ventilation compared to 30:2 chest compression with conventional BVM. Therefore, we investigated the ventilation efficacy of i-gel with the initial arterial blood gas analysis in OHCA patients visiting our ER. Material and Method: Demographics, arrest parameters including i-gel insertion, initial arterial blood gas analysis was retrospectively analysed for 119 transported OHCA patients that visited our ER. Linear regression was done to investigate the association with i-gel insertion and initial pCO2 as a surrogate of prehospital ventilation. Result: A total of 52 patients were analysed for the study. Of the patients who visited the ER during OHCA, 24 patients had i-gel insertion and 28 patients had BVM as airway management in the prehospital phase. Prehospital i-gel insertion was associated with the initial pCO2 level (B coefficient 29.9, SE 10.1, p<0.01) after adjusting for bystander CPR, cardiogenic cause of arrest, EMS call to arrival. Conclusion: Despite many limitations to the study, prehospital insertion of i-gel was associated with high initial pCO2 values in OHCA patients visiting our ER, possibly indicating insufficient ventilation with prehospital i-gel as an advanced airway and continuous chest compressions.

Keywords: arrest, I-gel, prehospital, ventilation

Procedia PDF Downloads 322
8792 Hypotensive, Free Radical Scavenging and Anti-Lipid Peroxidation Activities of Crataegus azarolus L. Leaves Extracts Growing in Algeria

Authors: Amel Bouaziz, Seddik Khennouf, Mussa Abu Zarga, Shtayway Abdalla, Saliha Djidel, Assia Bentahar, Saliha Dahamna, Smain Amira

Abstract:

The present study aimed to evaluate the hypotensive and the in vitro antioxidant activities of Crataegus azarolus L. (Rosaceae), a plant widely used as natural remedy for hypertension in folk medicine. The antioxidant potential of methanolic extract (ME)and its three fractions of Chloroform (CHE), ethyl acetate (EAE)and water (AqE) have been investigated using several assays, including the DPPH scavenging, ABTS scavenging, hydroxyl radical scavenging. Inhibition of lipid peroxidation was performed by the β-carotene bleaching assay, ferric thiocyanate method and thiobarburic acid method. Total phenolic and total flavonoid contents of the extracts were estimated using Folin-Chiocalteu reagent and AlCl3, respectively. EAE extract showed the highest polyphenolic and flavonoids contents (396,04±1.20 mg GAE/g of dry extract and 32,73 ± 0.03mg QE/g of dry extract) respectively. Similarly, this extract possessed the highest scavenging activity for DPPH radical (IC 50 = 0,006±0,0001mg /ml), ABTS radical (IC50=0.0035±0,0007 mg/ml) and hydroxyl radical(IC 50=0,283± 0.01 mg/ml). In addition, the EAE exhibited the highest antioxidant activity in the inhibition of linoleic acid/ß-carotene coupled oxidation (89,21%), lipid peroxidation in the ferric thiocyanate(FTC) method (90.13%), and thio-barbituric acid (TBA) method (74.23%). Intravenous administration of Me and EAE decreased mean arterial blood pressure, systolic and diastolic blood pressure in anesthetized rats dose-dependently, at the dose range of 0.4 to 12 mg/kg. The mean arterial blood pressure dropped by 27.58 and 39.37% for ME and EAE, respectively. In conclusion, The present study supported the significant potential to use C. azarolus by-products as a source of natural antioxidants and provides scientific justification for its traditional uses as cardio-protective and anti-hypertensive remedy.

Keywords: Crataegus azarolus, polyphenols, flavonoids, hypertension, antioxidant activity, free radicals, peroxidation

Procedia PDF Downloads 323
8791 An Extremely Rare Anatomical Vascular Variant of Lower Limb Arterial System - Duplication of Superficial Femoral Artery

Authors: Manik Sharma

Abstract:

Understanding the anatomy and normal anatomical variations of the lower limb arterial system is undeniably important not only to understand the pathology involving the vessels of the lower limb but also as a part of endovascular intervention and surgical planning in cases that demand them as a part of treatment. There have been very few cases of duplication of SFA cited in the literature, close to six worldwide and this being the seventh case in the world and first to be reported in the Indian population. We incidentally came across this normal variant during US lower limb (US-LL) duplex scan in a patient with claudicating pain in bilateral lower limbs hence suspected of having peripheral vascular disease. It was confirmed on CT-Peripheral Angiography (CT-PA), which was done successively.

Keywords: peripheral vascular disease, claudicating pain, normal anatomical variants, endovascular intervention, duplication, CT-peripheral angiography, duplex scan, Iohexol

Procedia PDF Downloads 150
8790 Subcutan Isosulfan Blue Administration May Interfere with Pulse Oximetry

Authors: Esra Yuksel, Dilek Duman, Levent Yeniay, Sezgin Ulukaya

Abstract:

Sentinel lymph node biopsy (SLNB) is a minimal invasive technique with lower morbidity in axillary staging of breast cancer. Isosulfan blue stain is frequently used in SLNB and regarded as safe. The present case report aimed to report severe decrement in SpO2 following isosulfan blue administration, as well as skin and urine signs and inconsistency with clinical picture in a 67-year-old ,77 kg, ASA II female case that underwent SLNB under general anesthesia. Ten minutes after subcutaneous administration of 10 ml 1% isosulfan blue by the surgeons into the patient, who were hemodynamically stable, SpO2 first reduced to 87% from 99%, and then to 75% in minutes despite 100% oxygen support. Meanwhile, blood pressure and EtCO2 monitoring was unremarkable. After specifying that anesthesia device worked normally, airway pressure did not increase and the endotracheal tube has been placed accurately, the blood sample was taken from the patient for arterial gas analysis. A severe increase was thought in MetHb concentration since SpO2 persisted to be 75% although the concentration of inspired oxygen was 100%, and solution of 2500 mg ascorbic acid in 500 ml 5% Dextrose was given to the patient via intravenous route until the results of arterial blood gas were obtained. However, arterial blood gas results were as follows: pH: 7.54, PaCO2: 23.3 mmHg, PaO2: 281 mmHg, SaO2: %99, and MetHb: %2.7. Biochemical analysis revealed a blood MetHb concentration of 2%.However, since arterial blood gas parameters were good, hemodynamics of the patient was stable and methemoglobin concentration was not so high, the patient was extubated after surgery when she was relaxed, cooperated and had adequate respiration. Despite the absence of respiratory or neurological distress, SpO2 value was increased only up to 85% within 2 hours with 5 L/min oxygen support via face mask in the surgery room as the patient was extubated. At that time, the skin of particularly the upper part of her body has turned into blue, more remarkable on the face. The color of plasma of the blood taken from the patient for biochemical analysis was blue. The color of urine coming throughout the urinary catheter placed in intensive care unit was also blue. Twelve hours after 5 L/min. oxygen inhalation via a mask, the SpO2 reached to 90%. During monitoring in intensive care unit on the postoperative 1st day, facial color and urine color of the patient was still blue, SpO2 was 92%, and arterial blood gas levels were as follows: pH: 7.44, PaO2: 76.1 mmHg, PaCO2: 38.2 mmHg, SaO2: 99%, and MetHb 1%. During monitoring in clinic on the postoperative 2nd day, SpO2 was 95% without oxygen support and her facial and urine color turned into normal. The patient was discharged on the 3rd day without any problem.In conclusion, SLNB is a less invasive alternative to axillary dissection. However, false pulse oximeter reading due to pigment interference is a rare complication of this procedure. Arterial blood gas analysis should be used to confirm any fall in SpO2 reading during monitoring.

Keywords: isosulfan blue, pulse oximetry, SLNB, methemoglobinemia

Procedia PDF Downloads 302
8789 Evaluation of Carbon Dioxide Pressure through Radial Velocity Difference in Arterial Blood Modeled by Drift Flux Model

Authors: Aicha Rima Cheniti, Hatem Besbes, Joseph Haggege, Christophe Sintes

Abstract:

In this paper, we are interested to determine the carbon dioxide pressure in the arterial blood through radial velocity difference. The blood was modeled as a two phase mixture (an aqueous carbon dioxide solution with carbon dioxide gas) by Drift flux model and the Young-Laplace equation. The distributions of mixture velocities determined from the considered model permitted the calculation of the radial velocity distributions with different values of mean mixture pressure and the calculation of the mean carbon dioxide pressure knowing the mean mixture pressure. The radial velocity distributions are used to deduce a calculation method of the mean mixture pressure through the radial velocity difference between two positions which is measured by ultrasound. The mean carbon dioxide pressure is then deduced from the mean mixture pressure.

Keywords: mean carbon dioxide pressure, mean mixture pressure, mixture velocity, radial velocity difference

Procedia PDF Downloads 404
8788 Total Arterial Coronary Revascularization with Aorto-Bifemoral Bipopliteal Bypass: A Case Report

Authors: Nuruddin Mohammod Zahangir, Syed Tanvir Ahmady, Firoz Ahmed, Mainul Kabir, Tamjid Mohammad Najmus Sakib Khan, Nazmul Hossain, Niaz Ahmed, Madhava Janardhan Naik

Abstract:

The management of combined Coronary Artery Disease and Peripheral Vascular Disease is a challenge and brings with it numerous clinical dilemmas.The 56 year old gentleman presented to our department with significant triple vessel disease with occluded lower end of aorta just before bifurcation and bilateral superficial femoral arteries. Operation was done on 11.03.14. The The Left Internal Mammary Artery (LIMA) and the Right Internal Mammary Artery (RIMA) were harvested in skeletonized manner. The free RIMA was then anastomosed with LIMA to make LIMA-RIMA Y. Cardio Pulmonary Bypass was then established and coronary artery bypass grafts performed. LIMA was anastomosed to the Left Anterior Descending artery. RIMA was anastomosed to Posterior Descending Artery, 1st and 2nd Obtuse Marginal arteries in a sequential manner. Abdomen was opened by midline incision. The infrarenal aorta exposed and was found to be severely diseased. A Vascular Clamp was applied infrarenally, aortotomy done and limited endarterectomy performed. An end-to-side anastomosis was done with upper end of PTFE synthetic Y-graft (14/7 mm) to the infarenal Aorta and the Clamp released. Good flow noted in both limbs of the graft. Patient was then slowly weaned off from Cardio Pulmonary Bypass without difficulty. The distal two limbs of the Y graft were passed to the groin through retroperitoneal tunnels and anastomosed end-to-side with the common femoral arteries. Saphenous vein was interposed between common femoral and popliteal arteries bilaterally through subfascial tunnels in both thigh. On 12th postoperative day he was discharged from hospital in good general condition. Follow up after 3 months of operation the patient is doing good and free of chest pain and claudication pain.

Keywords: total arterial, coronary revascularization, aorto-bifemoral bypass, bifemoro-bipopliteal bypass

Procedia PDF Downloads 452
8787 Advanced Real-Time Fluorescence Imaging System for Rat's Femoral Vein Thrombosis Monitoring

Authors: Sang Hun Park, Chul Gyu Song

Abstract:

Artery and vein occlusion changes observed in patients and experimental animals are unexplainable symptoms. As the fat accumulated in cardiovascular ruptures, it causes vascular blocking. Likewise, early detection of cardiovascular disease can be useful for treatment. In this study, we used the mouse femoral occlusion model to observe the arterial and venous occlusion changes without darkroom. We observed the femoral arterial flow pattern changes by proposed fluorescent imaging system using an animal model of thrombosis. We adjusted the near-infrared light source current in order to control the intensity of the fluorescent substance light. We got the clear fluorescent images and femoral artery flow pattern were measured by a 5-minute interval. The result showed that the fluorescent substance flowing in the femoral arteries were accumulated in thrombus as time passed, and the fluorescence of other vessels gradually decreased.

Keywords: thrombus, fluorescence, femoral, arteries

Procedia PDF Downloads 322
8786 Numerical Simulation of Magnetohydrodynamic (MHD) Blood Flow in a Stenosed Artery

Authors: Sreeparna Majee, G. C. Shit

Abstract:

Unsteady blood flow has been numerically investigated through stenosed arteries to achieve an idea about the physiological blood flow pattern in diseased arteries. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. For direct numerical simulation, vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman-Rachford Alternating Direction Implicit (ADI) scheme. The effects of magnetic parameter and Reynolds number on velocity and wall shear stress are being studied and presented quantitatively over the entire arterial segment. The streamlines have been plotted to understand the flow pattern in the stenosed artery, which has significant alterations in the downstream of the stenosis in the presence of magnetic field. The results show that there are nominal changes in the flow pattern when magnetic field strength is enhanced upto 8T which can have remarkable usage to MRI machines.

Keywords: magnetohydrodynamics, blood flow, stenosis, energy dissipation

Procedia PDF Downloads 259
8785 Analysis of Wall Deformation of the Arterial Plaque Models: Effects of Viscoelasticity

Authors: Eun Kyung Kim, Kyehan Rhee

Abstract:

Viscoelastic wall properties of the arterial plaques change as the disease progresses, and estimation of wall viscoelasticity can provide a valuable assessment tool for plaque rupture prediction. Cross section of the stenotic coronary artery was modeled based on the IVUS image, and the finite element analysis was performed to get wall deformation under pulsatile pressure. The effects of viscoelastic parameters of the plaque on luminal diameter variations were explored. The result showed that decrease of viscous effect reduced the phase angle between the pressure and displacement waveforms, and phase angle was dependent on the viscoelastic properties of the wall. Because viscous effect of tissue components could be identified using the phase angle difference, wall deformation waveform analysis may be applied to predict plaque wall composition change and vascular wall disease progression.

Keywords: atherosclerotic plaque, diameter variation, finite element method, viscoelasticity

Procedia PDF Downloads 205
8784 Retinal Vascular Tortuosity in Obstructive Sleep Apnea-COPD Overlap Patients

Authors: Rabab A. El Wahsh, Hatem M. Marey, Maha Yousif, Asmaa M. Ibrahim

Abstract:

Background: OSA and COPD are associated with microvascular changes. Retinal microvasculature can be directly and non-invasively examined. Aim: to evaluate retinal vascular tortuosity in patients with COPD, OSA, and overlap syndrome. Subjects and method: Sixty subjects were included; 15 OSA patients, 15 COPD patients, 15 COPD-OSA overlap patients, and 15 matched controls. They underwent digital retinal photography, polysomnography, arterial blood gases, spirometry, ESS, and stop-bang questionnaires. Results: Tortuosity of most retinal vessels was higher in all patient groups compared to the control group; tortuosity was more marked in overlap syndrome. There was a negative correlation between tortuosity of retinal vessels and PO2, O2 saturation, and minimum O2 desaturation, and a positive correlation with PCO2, AHI, O2 desaturation index, BMI and smoking index. Conclusion: Retinal vascular tortuosity occurs in OSA, COPD and overlap syndrome. Retinal vascular tortuosity is correlated with arterial blood gases parameters, polysomnographic findings, smoking index and BMI.

Keywords: OSA, COPD, overlap syndrome, retinal vascular tortuosity

Procedia PDF Downloads 49
8783 Dietary Flaxseed Decreases Central Blood Pressure and the Concentrations of Plasma Oxylipins Associated with Hypertension in Patients with Peripheral Arterial Disease

Authors: Stephanie PB Caligiuri, Harold M Aukema, Delfin Rodriguez-Leyva, Amir Ravandi, Randy Guzman, Grant N. Pierce

Abstract:

Background: Hypertension leads to cardiac and cerebral events and therefore is the leading risk factor attributed to death in the world. Oxylipins may be mediators in these events as they can regulate vascular tone and inflammation. Oxylipins are derived from fatty acids. Dietary flaxseed is rich in the n3 fatty acid, alpha-linolenic acid, and, therefore, may have the ability to change the substrate profile of oxylipins. As a result, this could alter blood pressure. Methods: A randomized, double-blinded, controlled clinical trial, the Flax-PAD trial, was used to assess the impact of dietary flaxseed on blood pressure (BP), and to also assess the relationship of plasma oxylipins to BP in 81 patients with peripheral arterial disease (PAD). Patients with PAD were chosen for the clinical trial as they are at an increased risk for hypertension and cardiac and cerebral events. Thirty grams of ground flaxseed were added to food products to consume on a daily basis for 6 months. The control food products contained wheat germ, wheat bran, and mixed dietary oils instead of flaxseed. Central BP, which is more significantly associated to organ damage, cardiac, and cerebral events versus brachial BP, was measured by pulse wave analysis at baseline and 6 months. A plasma profile of 43 oxylipins was generated using solid phase extraction, HPLC-MS/MS, and stable isotope dilution quantitation. Results: At baseline, the central BP (systolic/diastolic) in the placebo and flaxseed group were, 131/73 ± 2.5/1.4 mmHg and 128/71 ± 2.6/1.4 mmHg, respectively. After 6 months of intervention, the flaxseed group exhibited a decrease in blood pressure of 4.0/1.0 mmHg. The 6 month central BP in the placebo and flaxseed groups were, 132/74 ± 2.9/1.8 mmHg and 124/70 ± 2.6/1.6 mmHg (P<0.05). Correlation and logistic regression analyses between central blood pressure and oxylipins were performed. Significant associations were observed between central blood pressure and 17 oxylipins, primarily produced from arachidonic acid. Every 1 nM increase in 16-hydroxyeicosatetraenoic acid (HETE) increased the odds of having high central systolic BP by 15-fold, of having high central diastolic BP by 6-fold and of having high central mean arterial pressure by 15-fold. In addition, every 1 nM increase in 5,6-dihydroxyeicosatrienoic acid (DHET) and 11,12-DHET increased the odds of having high central mean arterial pressure by 45- and 18-fold, respectively. Flaxseed induced a significant decrease in these as well as 4 other vasoconstrictive oxylipins. Conclusion: Dietary flaxseed significantly lowered blood pressure in patients with PAD and hypertension. Plasma oxylipins were strongly associated with central blood pressure and may have mediated the flaxseed-induced decrease in blood pressure.

Keywords: hypertension, flaxseed, oxylipins, peripheral arterial disease

Procedia PDF Downloads 451
8782 Design and Assessment of Traffic Management Strategies for Improved Mobility on Major Arterial Roads in Lahore City

Authors: N. Ali, S. Nakayama, H. Yamaguchi, M. Nadeem

Abstract:

Traffic congestion is a matter of prime concern in developing countries. This can be primarily attributed due to poor design practices and biased allocation of resources based on political will neglecting the technical feasibilities in infrastructure design. During the last decade, Lahore has expanded at an unprecedented rate as compared to surrounding cities due to more funding and resource allocation by the previous governments. As a result of this, people from surrounding cities and areas moved to the Lahore city for better opportunities and quality of life. This migration inflow inherited the city with an increased population yielding the inefficiency of the existing infrastructure to accommodate enhanced traffic demand. This leads to traffic congestion on major arterial roads of the city. In this simulation study, a major arterial road was selected to evaluate the performance of the five intersections by changing the geometry of the intersections or signal control type. Simulations were done in two software; Highway Capacity Software (HCS) and Synchro Studio and Sim Traffic Software. Some of the traffic management strategies that were employed include actuated-signal control, semi-actuated signal control, fixed-time signal control, and roundabout. The most feasible solution for each intersection in the above-mentioned traffic management techniques was selected with the least delay time (seconds) and improved Level of Service (LOS). The results showed that Jinnah Hospital Intersection and Akbar Chowk Intersection improved 92.97% and 92.67% in delay time reduction, respectively. These results can be used by traffic planners and policy makers for decision making for the expansion of these intersections keeping in mind the traffic demand in future years.

Keywords: traffic congestion, traffic simulation, traffic management, congestion problems

Procedia PDF Downloads 454
8781 A Mathematical Model of Blood Perfusion Dependent Temperature Distribution in Transient Case in Human Dermal Region

Authors: Yogesh Shukla

Abstract:

Many attempts have been made to study temperature distribution problem in human tissues under normal environmental and physiological conditions at constant arterial blood temperature. But very few attempts have been made to investigate temperature distribution in human tissues under different arterial blood temperature. In view of above, a finite element model has been developed to unsteady temperature distribution in dermal region in human body. The model has been developed for one dimension unsteady state case. The variation in parameters like thermal conductivity, blood mass flow and metabolic activity with respect to position and time has been incorporated in the model. Appropriate boundary conditions have been framed. The central difference approach has been used in space variable and trapezoidal rule has been employed a long time variable. Numerical results have been obtained to study relationship among temperature and time.

Keywords: rate of metabolism, blood mass flow rate, thermal conductivity, heat generation, finite element method

Procedia PDF Downloads 335
8780 Association of Ankle Brachial Index with Diabetic Score Neuropathy Examination in Type 2 Diabetes Melitus Patients

Authors: A. K. Putri, A.Fitri, C. A. Batubara

Abstract:

Diabetes Mellitus (DM) is a chronic disease that could cause complications. The complication can be Peripheral Arterial Disease (PAD) or Diabetic Neuropathy (DN). Peripheral Arterial Disease is checked by Ankle Brachial Index (ABI), DN is checked by Diabetic Neuropathy Examination (DNE) score. To determine the association of ABI and DNE score in DM type 2. This study uses a cross-sectional design. The subjects were DM patients at the neurology and endocrinology polyclinic at Haji Adam Malik Hospital Medan and its network hospital and this study subjects were examined for ABI and DNE scores. The data were analysed using the Fisher Exact statistics test. Demographics characteristic showed most of subject are female (51,6%), age range ≥ 60 (45.2% ; average 57,6 ± 9,8 years ), and history of DM 5-10 years (45,2%). The most patient ABI characteristics were mild PAD (42%) and moderate PAD (29%). The most patient DNE Score characteristics were≥ 3 (51,6%). There’s a significant relationship between ABI and DNE score in DM type 2 (p =0.016). Conclusion: There is a significant association between ABI and DNE scores in DM type 2 patients

Keywords: diabetic neuropathy, diabetes mellitus, ankle-brachial index, diabetic neuropathy examination

Procedia PDF Downloads 99
8779 Congestion Mitigation on an Urban Arterial through Infrastructure Intervention

Authors: Attiq Ur Rahman Dogar, Sohaib Ishaq

Abstract:

Pakistan had experienced rapid motorization in the last decade. Due to the soft leasing schemes of banks and increase in average household income, even the middle class can now afford cars. The public transit system is inadequate and sparse. Due to these reasons, traffic demand on urban arterials has increased manifold. Poor urban transit planning and aging transportation systems have resulted in traffic congestion. The focus of this study is to improve traffic flow on a section of N-5 passing through the Rawalpindi downtown. Present efforts aim to carry out the analysis of traffic conditions on this section and to investigate the impact of traffic signal co-ordination on travel time. In addition to signal co-ordination, we also examined the effect of different infrastructure improvements on the travel time. After the economic analysis of alternatives and discussions, the improvement plan for Rawalpindi downtown urban arterial section is proposed for implementation.

Keywords: signal coordination, infrastructure intervention, infrastructure improvement, cycle length, fuel consumption cost, travel time cost, economic analysis, travel time, Rawalpindi, Pakistan, traffic signals

Procedia PDF Downloads 302
8778 Comparison Of Virtual Non-Contrast To True Non-Contrast Images Using Dual Layer Spectral Computed Tomography

Authors: O’Day Luke

Abstract:

Purpose: To validate virtual non-contrast reconstructions generated from dual-layer spectral computed tomography (DL-CT) data as an alternative for the acquisition of a dedicated true non-contrast dataset during multiphase contrast studies. Material and methods: Thirty-three patients underwent a routine multiphase clinical CT examination, using Dual-Layer Spectral CT, from March to August 2021. True non-contrast (TNC) and virtual non-contrast (VNC) datasets, generated from both portal venous and arterial phase imaging were evaluated. For every patient in both true and virtual non-contrast datasets, a region-of-interest (ROI) was defined in aorta, liver, fluid (i.e. gallbladder, urinary bladder), kidney, muscle, fat and spongious bone, resulting in 693 ROIs. Differences in attenuation for VNC and TNV images were compared, both separately and combined. Consistency between VNC reconstructions obtained from the arterial and portal venous phase was evaluated. Results: Comparison of CT density (HU) on the VNC and TNC images showed a high correlation. The mean difference between TNC and VNC images (excluding bone results) was 5.5 ± 9.1 HU and > 90% of all comparisons showed a difference of less than 15 HU. For all tissues but spongious bone, the mean absolute difference between TNC and VNC images was below 10 HU. VNC images derived from the arterial and the portal venous phase showed a good correlation in most tissue types. The aortic attenuation was somewhat dependent however on which dataset was used for reconstruction. Bone evaluation with VNC datasets continues to be a problem, as spectral CT algorithms are currently poor in differentiating bone and iodine. Conclusion: Given the increasing availability of DL-CT and proven accuracy of virtual non-contrast processing, VNC is a promising tool for generating additional data during routine contrast-enhanced studies. This study shows the utility of virtual non-contrast scans as an alternative for true non-contrast studies during multiphase CT, with potential for dose reduction, without loss of diagnostic information.

Keywords: dual-layer spectral computed tomography, virtual non-contrast, true non-contrast, clinical comparison

Procedia PDF Downloads 127
8777 Prevalence and Clinical Significance of Antiphospholipid Antibodies in COVID-19 Patients Admitted to Intensive Care Units

Authors: Mostafa Najim, Alaa Rahhal, Fadi Khir, Safae Abu Yousef, Amer Aljundi, Feryal Ibrahim, Aliaa Amer, Ahmed Soliman Mohamed, Samira Saleh, Dekra Alfaridi, Ahmed Mahfouz, Sumaya Al-Yafei, Faraj Howady, Mohamad Yahya Khatib, Samar Alemadi

Abstract:

Background: Coronavirus disease 2019 (COVID-19) increases the risk of coagulopathy among critically ill patients. Although the presence of antiphospholipid antibodies (aPLs) has been proposed as a possible mechanism of COVID-19 induced coagulopathy, their clinical significance among critically ill patients with COVID-19 remains uncertain. Methods: This prospective observational study included patients with COVID-19 admitted to intensive care units (ICU) to evaluate the prevalence and clinical significance of aPLs, including anticardiolipin IgG/IgM, anti-β2-glycoprotein IgG/IgM, and lupus anticoagulant. The study outcomes included the prevalence of aPLs, a primary composite outcome of all-cause mortality, and arterial or venous thrombosis among aPLs positive patients versus aPLs negative patients during their ICU stay. Multiple logistic regression was used to assess the influence of aPLs on the primary composite outcome of mortality and thrombosis. Results: A total of 60 critically ill patients were enrolled. Of whom, 57 (95%) were male, with a mean age of 52.8 ± 12.2 years, and the majority were from Asia (68%). Twenty-two patients (37%) were found to have positive aPLs; of whom 21 patients were positive for lupus anticoagulant, whereas one patient was positive for anti-β2-glycoprotein IgG/IgM. The composite outcome of mortality and thrombosis during ICU did not differ among patients with positive aPLs compared to those with negative aPLs (4 (18%) vs. 6 (16%), aOR= 0.98, 95% CI 0.1-6.7; p-value= 0.986). Likewise, the secondary outcomes, including all-cause mortality, venous thrombosis, arterial thrombosis, discharge from ICU, time to mortality, and time to discharge from ICU, did not differ between those with positive aPLs upon ICU admission in comparison to patients with negative aPLs. Conclusion: The presence of aPLs does not seem to affect the outcomes of critically ill patients with COVID-19 in terms of all-cause mortality and thrombosis. Therefore, clinicians may not screen critically ill patients with COVID-19 for aPLs unless deemed clinically appropriate.

Keywords: antiphospholipid antibodies, critically ill patients, coagulopathy, coronavirus

Procedia PDF Downloads 149
8776 The Lamination and Arterial Blood Supply of the Masseter Muscle of Camel (Camelus dromedarius)

Authors: Elsyed Fath Khalifa, Samer Mohamed Daghash

Abstract:

The present study was carried out to investigate the structure of the masseter muscle of camel and its attachments to the skull as well as the relationships with its arterial blood supply. Fourteen heads of clinically healthy camels of different ages and sexes were used in the present investigation. The both common carotid arteries of six specimens were cannulated and flushed with warm normal saline solution (0.9%) then injected with red colored neoprine (60%) latex in order to study the pattern of the blood supply to the masseter muscle. Two heads were injected with an eventually mixture of 75gm red lead oxide in 150cc latex and preserved in a cold room for 3-4 days then divided sagittaly along the median plane to avoid super imposition of the arteries. The arteries of the masseter muscle of each half were radiographed. Four heads were used in manual dissection to describe the laminar arrangement of the masseter muscle. The masseter muscle of the camel was very tendinous and was situated far caudally, which enable the camel to open its jaw very wide. In the camel, the masseter muscle was recognized into proper and improper masseter groups. The proper group included the first, second superficial, intermediate and deep masseter layers. The improper group consisted of maxillo-mandibularis and zygomatico-mandibularis. The remaining two heads were used for clearance.

Keywords: anatomy, camel, masseter, lamination, blood supply

Procedia PDF Downloads 305
8775 GUI Design of Mathematical Model of Cardiovascular-Respiratory System

Authors: Ntaganda J.M., Maniraguha J.D., Mukeshimana S., Harelimana D, Bizimungu T., Ruataganda E.

Abstract:

This paper presents the design of Graphic User Interface (GUI) in Matlab as interaction tool between human and machine. The designed GUI can be used by medical doctors and other experts particularly the physiologists. Matlab packages and estimated parameters of the mathematical model of cardiovascular-respiratory system developed in Rwandan context are used in GUI. The ordinary differential equations (ODE’s) govern a mathematical model in designing GUI in Matlab and a window that sets model estimated parameters and the measured parameters by any user. For healthy subject, these measured parameters include heart rate, systolic blood and diastolic blood pressure, partial pressure of oxygen in arterial blood, partial pressure of carbon dioxide in arterial blood, concentration of bound and dissolved oxygen in the mixed venous blood entering the lungs, and concentration of bound and dissolved carbon dioxide in the mixed venous blood entering the lungs. The results of numerical test give a consistent appearance as empirically known results.

Keywords: Graphic User Interface, mathematical model, cardiovascur-respiratory system, walking physical activity, blood pressure, oxygen

Procedia PDF Downloads 104
8774 The Affect of Total Quality Management on Firm's Innovation Performance: A Literature Review

Authors: Omer Akkaya, Nurullah Ekmekcı, Muammer Zerenler

Abstract:

Innovation for businesses means a new product and service and sometimes a new implementation. Total Quality Management is a management philosophy which focus on customer, process and system.There is a certain relationship between principles of Total Quality Management and innovation performance. Main aim of this study is to show how the implementation and principles of Total Quality Management (TQM) affect a firm's innovation performance. Also, this paper discusses positive and negative affects of Total Quality Management on innovation performance and demonstrates some examples.

Keywords: innovation, innovation types, total quality management, principles of total quality management

Procedia PDF Downloads 611
8773 Analysis on Yogyakarta Istimewa Citygates on Urban Area Arterial Roads

Authors: Nizar Caraka Trihanasia, Suparwoko

Abstract:

The purpose of this paper is to analyze the design model of city gates on arterial roads as Yogyakarta’s “Istimewa” (special) identity. City marketing has become a trend among cities in the past few years. It began to compete with each other in promoting their identity to the world. One of the easiest ways to recognize the identity is by knowing the image of the city which can be seen through architectural buildings or urban elements. The idea is to recognize how the image of the city can represent Yogyakarta’s identity, which is limited to the contribution of the city gates distinctiveness on Yogyakarta urban area. This study has concentrated on the aspect of city gates as built environment that provides a diversity, configuration and scale of development that promotes a sense of place and community. The visual analysis will be conducted to interpreted the existing Yogyakarta city gates (as built environment) focussing on some variables of 1) character and pattern, 2) circulation system establishment, and 3) open space utilisation. Literature review and site survey are also conducted to understand the relationship between the built environment and the sense of place in the community. This study suggests that visually the Yogyakarta city gate model has strong visual characters and pattern by using the concept of a sense of place of Yogyakarta community value.

Keywords: visual analysis, model, Yogyakarta “Istimewa”, citygates

Procedia PDF Downloads 238
8772 Maximizing Bidirectional Green Waves for Major Road Axes

Authors: Christian Liebchen

Abstract:

Both from an environmental perspective and with respect to road traffic flow quality, planning so-called green waves along major road axes is a well-established target for traffic engineers. For one-way road axes (e.g. the Avenues in Manhattan), this is a trivial downstream task. For bidirectional arterials, the well-known necessary condition for establishing a green wave in both directions is that the driving times between two subsequent crossings must be an integer multiple of half of the cycle time of the signal programs at the nodes. In this paper, we propose an integer linear optimization model to establish fixed-time green waves in both directions that are as long and as wide as possible, even in the situation where the driving time condition is not fulfilled. In particular, we are considering an arterial along whose nodes separate left-turn signal groups are realized. In our computational results, we show that scheduling left-turn phases before or after the straight phases can reduce waiting times along the arterial. Moreover, we show that there is always a solution with green waves in both directions that are as long and as wide as possible, where absolute priority is put on just one direction. Compared to optimizing both directions together, establishing an ideal green wave into one direction can only provide suboptimal quality when considering prioritized parts of a green band (e.g., first few seconds).

Keywords: traffic light coordination, synchronization, phase sequencing, green waves, integer programming

Procedia PDF Downloads 100
8771 Evaluation of the Effect of Intravenous Dexamethasone on Hemodynamic Variables and Hypotension in Female Undergoing Cesarean Section With Spinal Anesthesia

Authors: Shekoufeh Behdad, Sahar Yadegari, Alireza Ghehrazad, Amirhossein Yadegari

Abstract:

Background: In this study, we compared the effect of intravenous dexamethasone with placebo on hemodynamic variables and hypotension in patients undergoing cesarean section under spinal anesthesia. Materials and methods: This double-blind, randomized clinical trial was conducted with the approval of the university ethics committee. Written informed consent was obtained from all participating patients. Before spinal anesthesia, patients were randomly assigned to receive either dexamethasone (8 mg IV) or placebo (normal saline). Hemodynamic variables, including systolic, diastolic, and mean arterial blood pressures, as well as heart rate, were measured before drug administration and every 3 minutes until the birth of the neonate and then every 5 minutes until the end of surgery. Side effects such as hypotension, bradycardia, nausea, and vomiting were assessed and recorded for all the patients. Results: There were no significant differences in mean systolic, diastolic, and mean arterial blood pressures before and after administration of the studied drugs in both groups (P.Value>0.05), but heart rate and the incidence of hypotension in the dexamethasone group were less than placebo significantly. Conclusions: Intravenous administration of 8 mg dexamethasone before spinal anesthesia in females undergoing cesarean section can reduce the incidence of post-spinal hypotension without causing serious side effects.

Keywords: cesarean section, hypotension, spinal anesthesia, dexamethasone

Procedia PDF Downloads 57