Search results for: sacroiliac joint MRI
1054 Effect of Sensory Manipulations on Human Joint Stiffness Strategy and Its Adaptation for Human Dynamic Stability
Authors: Aizreena Azaman, Mai Ishibashi, Masanori Ishizawa, Shin-Ichiroh Yamamoto
Abstract:
Sensory input plays an important role to human posture control system to initiate strategy in order to counterpart any unbalance condition and thus, prevent fall. In previous study, joint stiffness was observed able to describe certain issues regarding to movement performance. But, correlation between balance ability and joint stiffness is still remains unknown. In this study, joint stiffening strategy at ankle and hip were observed under different sensory manipulations and its correlation with conventional clinical test (Functional Reach Test) for balance ability was investigated. In order to create unstable condition, two different surface perturbations (tilt up-tilt (TT) down and forward-backward (FB)) at four different frequencies (0.2, 0.4, 0.6 and 0.8 Hz) were introduced. Furthermore, four different sensory manipulation conditions (include vision and vestibular system) were applied to the subject and they were asked to maintain their position as possible. The results suggested that joint stiffness were high during difficult balance situation. Less balance people generated high average joint stiffness compared to balance people. Besides, adaptation of posture control system under repetitive external perturbation also suggested less during sensory limited condition. Overall, analysis of joint stiffening response possible to predict unbalance situation faced by human.Keywords: balance ability, joint stiffness, sensory, adaptation, dynamic
Procedia PDF Downloads 4591053 Relationship between Joint Hypermobility and Balance in Patients with Down’s Syndrome
Authors: Meltem Ramoglu, Ertugrul Safran, Hikmet Ucgun, Busra Kepenek Varol, Hulya Nilgun Gurses
Abstract:
Down’s syndrome (DS) is a human genetic disorder caused by the presence of all or part of an extra chromosome 21. Many patients with DS have musculoskeletal problems that affect weak muscle tone (hypotonia) and ligament laxity. This leads to excessive joint hypermobility and decreased position sense (proprioception). Lack of proprioception may cause balance problems. The aim of our study was to investigate how does joint hypermobility affect balance in patients with DS. Our study conducted with 13 DS patients age between 18 to 40 years. Demographic data were recorded. Beighton Hypermobility Score (BHS) was used to evaluate joint hypermobility. Balance score of participants was evaluated with Berg Balance Scale (BBS). Mean age of our participants was 29,8±3,57 year. Average score of body mass index and BHS were; 33,23 ±3,78 kg/m2 and 7,61±1,04, respectively. Out of a maximum possible score of 56 on the Berg Balance Scale, scores of participants with DS ranged from 36–51, with a mean of 43±4,45. Significant correlation was found between BHS and BBS (r: -,966, p=0.00). All of our participants have 6/9 or higher grade from BHS. As a conclusion of our study; joint hypermobility may affect balance score in patients with DS. The results suggest that people with DS have worse balance scores which affected by hypermobility. Further studies need larger population for more reliable results.Keywords: adults, balance, Down's syndrome, joint hypermobility
Procedia PDF Downloads 3291052 Piping Fragility Composed of Different Materials by Using OpenSees Software
Authors: Woo Young Jung, Min Ho Kwon, Bu Seog Ju
Abstract:
A failure of the non-structural component can cause significant damages in critical facilities such as nuclear power plants and hospitals. Historically, it was reported that the damage from the leakage of sprinkler systems, resulted in the shutdown of hospitals for several weeks by the 1971 San Fernando and 1994 North Ridge earthquakes. In most cases, water leakages were observed at the cross joints, sprinkler heads, and T-joint connections in piping systems during and after the seismic events. Hence, the primary objective of this study was to understand the seismic performance of T-joint connections and to develop an analytical Finite Element (FE) model for the T-joint systems of 2-inch fire protection piping system in hospitals subjected to seismic ground motions. In order to evaluate the FE models of the piping systems using OpenSees, two types of materials were used: 1) Steel 02 materials and 2) Pinching 4 materials. Results of the current study revealed that the nonlinear moment-rotation FE models for the threaded T-joint reconciled well with the experimental results in both FE material models. However, the system-level fragility determined from multiple nonlinear time history analyses at the threaded T-joint was slightly different. The system-level fragility at the T-joint, determined by Pinching 4 material was more conservative than that of using Steel 02 material in the piping system.Keywords: fragility, t-joint, piping, leakage, sprinkler
Procedia PDF Downloads 3031051 Parametric Study for Optimal Design of Hybrid Bridge Joint
Authors: Bongsik Park, Jae Hyun Park, Jae-Yeol Cho
Abstract:
Mixed structure, which is a kind of hybrid system, is incorporating steel beam and prestressed concrete beam. Hybrid bridge adopting mixed structure have some merits. Main span length can be made longer by using steel as main span material. In case of cable-stayed bridge having asymmetric span length, negative reaction at side span can be restrained without extra restraining devices by using weight difference between main span material and side span material. However angle of refraction might happen because of rigidity difference between materials and stress concentration also might happen because of abnormal loading transmission at joint in the hybrid bridge. Therefore the joint might be a weak point of the structural system and it needs to pay attention to design of the joint. However, design codes and standards about the joint in the hybrid-bridge have not been established so the joint designs in most of construction cases have been very conservative or followed previous design without extra verification. In this study parametric study using finite element analysis for optimal design of hybrid bridge joint is conducted. Before parametric study, finite element analysis was conducted based on previous experimental data and it is verified that analysis result approximated experimental data. Based on the finite element analysis results, parametric study was conducted. The parameters were selected as those have influences on joint behavior. Based on the parametric study results, optimal design of hybrid bridge joint has been determined.Keywords: parametric study, optimal design, hybrid bridge, finite element analysis
Procedia PDF Downloads 4251050 Suggestion of Reasonable Analysis Model for T-Girder Modular Bridge
Authors: Soonwon Kang, Jinwoong Choi, Sungnam Hong, Seung-Kyung Kye, Sun-Kyu Park
Abstract:
The modular bridge is to be constructed by assembling standardized precast segments. This bridge is classified as a slab type and T-girder type. The T-girder bridge has transverse joint. However, it did not perform the verification on the transverse joint, but the slab type was done on the analytic study on the joint. Therefore, it is necessary for precast modular T-girder bridge that has a transverse joint to propose an appropriated model. In this study, specimens and analysis models compared integrated type with segmented type. Results of the integrated and segmented specimens, each of the deflection was 98.40mm and 74.66mm when the maximum load was 269.71kN and 248.29kN, in case of the modeling the specimens, each of the deflection was 84.04mm, 69.39mm when the maximum load was 269.71kN, 248.29kN, therefore, the precast T-girder modular bridges form the analytic model proposed appropriate.Keywords: precast, T-girder modular bridge, finite element analysis, joint
Procedia PDF Downloads 4161049 Modifications in Design of Lap Joint of Fiber Metal Laminates
Authors: Shaher Bano, Samia Fida, Asif Israr
Abstract:
The continuous development and exploitation of materials and designs have diverted the attention of the world towards the use of robust composite materials known as fiber-metal laminates in many high-performance applications. The hybrid structure of fiber metal laminates makes them a material of choice for various applications such as aircraft skin panels, fuselage floorings, door panels and other load bearing applications. The synergistic effect of properties of metals and fibers reinforced laminates are responsible for their high damage tolerance as the metal element provides better fatigue and impact properties, while high stiffness and better corrosion properties are inherited from the fiber reinforced matrix systems. They are mostly used as a layered structure in different joint configurations such as lap and but joints. The FML layers are usually bonded with each other using either mechanical fasteners or adhesive bonds. This research work is also focused on modification of an adhesive bonded joint as a single lap joint of carbon fibers based CARALL FML has been modified to increase interlaminar shear strength and avoid delamination. For this purpose different joint modification techniques such as the introduction of spews and shoulder to modify the bond shape and use of nanofillers such as carbon nano-tubes as a reinforcement in the adhesive materials, have been utilized to improve shear strength of lap joint of the adhesively bonded FML layers. Both the simulation and experimental results showed that lap joint with spews and shoulders configuration have better properties due to stress distribution over a large area at the corner of the joint. The introduction of carbon nanotubes has also shown a positive effect on shear stress and joint strength as they act as reinforcement in the adhesive bond material.Keywords: adhesive joint, Carbon Reinforced Aluminium Laminate (CARALL), fiber metal laminates, spews
Procedia PDF Downloads 2991048 Evaluation the Influence of Trunk Bracing in Joint Contact Forces in Subjects with Scoliosis
Authors: Azadeh Jafari, Mohammad Taghi Karimi, Azadeh Nadi
Abstract:
Background: Scoliosis is the lateral curvature of the spine which may influence the abilities of the subjects during standing and walking. Most of the scoliotic subjects use orthosis to reduce the curve and to decrease the risk of curve progression. There was lack of information regarding the effects of orthosis on kinematic and joint contact force. Therefore, this research was done to highlight the effects of orthosis on the aforementioned parameters. Method: 5 scoliotic subjects were recruited in this study, with single curve less than 40 (females with age 13.2 ± 1.7). They were asked to walk with and without orthosis. The kinematic of the joints, force applied on the legs, moments transmitted through the joints and joint contact forces were evaluated in this study. Moreover, the lengths of muscles were determined by use of computer muscle control approach in OpenSim. Results: There was a significant difference between the second peak of vertical ground reaction force while walking with and without orthosis (p-value < 0.05). There was no difference between spatiotemporal gait parameters while walking with and without orthosis (P-value > 0.05). The mean values of joint contact forces (vertical component) increased by the use of orthosis, but the difference was not significant (p-value > 0.05). Conclusion: Although the kinematic of most of the body joints was not influenced by the use of orthosis, the joint contact force may be increased by orthosis. The increase in joint contact force may be due to the performance of orthosis which restricts the motions of pelvic and increases compensatory mechanism used by the subjects to decrease the side effects of the orthosis.Keywords: scoliosis, joint contact force, kinetic, kinematic
Procedia PDF Downloads 2101047 Micro-Study of Dissimilar Welded Materials
Authors: Ezzeddin Anawa, Abdol-Ghane Olabi
Abstract:
The dissimilar joint between aluminum /titanium alloys (Al 6082 and Ti G2) alloys were successfully achieved by CO2 laser welding with a single pass and without filler material using the overlap joint design. Laser welding parameters ranges combinations were experimentally determined using Taguchi approach with the objective of producing welded joint with acceptable welding profile and high quality of mechanical properties. In this study a joining of dissimilar Al 6082 / Ti G2 was result in three distinct regions fusion area (FA), heat-affected zone (HAZ), and the unaffected base metal (BM) in the weldment. These regions are studied in terms of its microstructural characteristics and microhardness which are directly affecting the welding quality. The weld metal was mainly composed of martensite alpha prime. In two different metals in the two different sides of joint HAZ, grain growth was detected. The microhardness of the joint distribution also has shown microhardness increasing in the HAZ of two base metals and a varying microhardness in fusion zone.Keywords: microharness , microstructure, laser welding and dissimilar jointed materials.
Procedia PDF Downloads 3741046 Quantification of Soft Tissue Artefacts Using Motion Capture Data and Ultrasound Depth Measurements
Authors: Azadeh Rouhandeh, Chris Joslin, Zhen Qu, Yuu Ono
Abstract:
The centre of rotation of the hip joint is needed for an accurate simulation of the joint performance in many applications such as pre-operative planning simulation, human gait analysis, and hip joint disorders. In human movement analysis, the hip joint center can be estimated using a functional method based on the relative motion of the femur to pelvis measured using reflective markers attached to the skin surface. The principal source of errors in estimation of hip joint centre location using functional methods is soft tissue artefacts due to the relative motion between the markers and bone. One of the main objectives in human movement analysis is the assessment of soft tissue artefact as the accuracy of functional methods depends upon it. Various studies have described the movement of soft tissue artefact invasively, such as intra-cortical pins, external fixators, percutaneous skeletal trackers, and Roentgen photogrammetry. The goal of this study is to present a non-invasive method to assess the displacements of the markers relative to the underlying bone using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction (all with knee extended) of the hip joint. Results show that the artefact skin marker displacements are non-linear and larger in areas closer to the hip joint. Also marker displacements are dependent on the movement type and relatively larger in abduction movement. The quantification of soft tissue artefacts can be used as a basis for a correction procedure for hip joint kinematics.Keywords: hip joint center, motion capture, soft tissue artefact, ultrasound depth measurement
Procedia PDF Downloads 2811045 Description of Geotechnical Properties of Jabal Omar
Authors: Ibrahim Abdel Gadir Malik, Dafalla Siddig Dafalla, Osama Abdelgadir El-Bushra
Abstract:
Geological and engineering characteristics of intact rock and the discontinuity surfaces was used to describe and classify rock mass into zones based on mechanical and physical properties. Many conditions terms that affect the rock mas; such as Rock strength, Rock Quality Designation (RQD) value, joint spacing, and condition of joint, water condition with block size, joint roughness, separation, joint hardness, friction angle and weathering were used to classify the rock mass into: Good quality (class II) (RMR values range between 75% and 56%), Good to fair quality (class II to III) (RMR values range between 70% and 55%), Fair quality (class III) (RMR values range between 60% and 50%) and Fair to poor quality (Class III to IV) (RMR values, range between (50% and 35%).Keywords: rock strength, RQD, joints, weathering
Procedia PDF Downloads 4161044 Effect of Forging Pressure on Mechanical Properties and Microstructure of Similar and Dissimilar Friction Welded Joints (Aluminium, Copper, Steel)
Authors: Sagar Pandit
Abstract:
The present work focuses on the effect of various process parameters on the mechanical properties and microstructure of joints produced by continuous drive friction welding and linear friction welding. An attempt is made to investigate the feasibility of obtaining an acceptable weld joint between similar as well as dissimilar components and the microstructural changes have also been assessed once the good weld joints were considered (using Optical Microscopy and Scanning Electron Microscopy techniques). The impact of forging pressure in the microstructure of the weld joint has been studied and the variation in joint strength with varying forge pressure is analyzed. The weld joints were obtained two pair of dissimilar materials and one pair of similar materials, which are listed respectively as: Al-AA5083 & Cu-C101 (dissimilar), Aluminium alloy-3000 series & Mild Steel (dissimilar) and High Nitrogen Austenitic Stainless Steel pair (similar). Intermetallic phase formation was observed at the weld joints in the Al-Cu joint, which consequently harmed the properties of the joint (less tensile strength). It was also concluded that the increase in forging pressure led to both increment and decrement in the tensile strength of the joint depending on the similarity or dissimilarity of the components. The hardness was also observed to possess maximum as well as minimum values at the weld joint depending on the similarity or dissimilarity of workpieces. It was also suggested that a higher forging pressure is needed to obtain complete joining for the formation of the weld joint.Keywords: forging pressure, friction welding, mechanical properties, microstructure
Procedia PDF Downloads 1181043 Robust Design of a Ball Joint Considering Uncertainties
Authors: Bong-Su Sin, Jong-Kyu Kim, Se-Il Song, Kwon-Hee Lee
Abstract:
An automobile ball joint is a pivoting element used to allow rotational motion between the parts of the steering and suspension system. And it plays a role in smooth transmission of steering movement, also reduction in impact from the road surface. A ball joint is under various repeated loadings that may cause cracks and abrasion. This damages lead to safety problems of a car, as well as reducing the comfort of the driver's ride, and raise questions about the ball joint procedure and the whole durability of the suspension system. Accordingly, it is necessary to ensure the high durability and reliability of a ball joint. The structural responses of stiffness and pull-out strength were then calculated to check if the design satisfies the related requirements. The analysis was sequentially performed, following the caulking process. In this process, the deformation and stress results obtained from the analysis were saved. Sequential analysis has a strong advantage, in that it can be analyzed by considering the deformed shape and residual stress. The pull-out strength means the required force to pull the ball stud out from the ball joint assembly. The low pull-out strength can deteriorate the structural stability and safety performances. In this study, two design variables and two noise factors were set up. Two design variables were the diameter of a stud and the angle of a socket. And two noise factors were defined as the uncertainties of Young's modulus and yield stress of a seat. The DOE comprises 81 cases using these conditions. Robust design of a ball joint was performed using the DOE. The pull-out strength was generated from the uncertainties in the design variables and the design parameters. The purpose of robust design is to find the design with target response and smallest variation.Keywords: ball joint, pull-out strength, robust design, design of experiments
Procedia PDF Downloads 4221042 Attachments of the Distal Oblique Membrane and Distal Oblique Bundle to the Distal Radioulnar Joint Capsule and Septum of Extensor Tendon Sheath
Authors: Yuri Seu, Seong-Kyu Choi, Hyun Jin Park, Jin Seo Park, HongtaeKim, Mi-Sun Hur
Abstract:
The aim of this study was to clarify the attachments of the distal oblique membrane (DOM) and distal oblique bundle (DOB) of the interosseous membrane of the forearm. The distal oblique membrane was investigated in the 21 specimens of 11 Korean cadavers. The muscles in the forearms were removed to observe the DOB. The DOB was found in 13 of 21 specimens (61.9 %). The DOB was attached to the distal radioulnar joint capsule and the septum between the tendons of the extensor digiti minimi (EDM) and extensor carpi ulnaris (ECU) as well as the radius and ulna. In the cases that the DOB was absent, a part of the DOM extended to the distal radioulnar joint capsule and the septum between the tendons of the EDM and ECU, as well as the radius and ulna in all specimens (100%). The DOM, including the DOB, was arranged obliquely in the anteroposterior direction, whereas the intermediate part of the interosseous membrane was arranged in the same plane between the radius and ulna. The extension of the DOM and DOB to the wrist region may stabilize the distal radioulnar joint during supination and pronation. These data will be useful when performing reconstructive surgeries.Keywords: distal oblique membrane, distal oblique bundle, distal radioulnar joint capsule, interosseous membrane
Procedia PDF Downloads 901041 The Effects of Seat Heights and Obesity on Lower-Limb Joint Kinematics during Sit-To-Stand Movement
Authors: Seungwon Baek, Haeseok Jeong, Haehyun Lee, Woojin Park
Abstract:
The main purpose of this study was to compare obese people to the non-obese in terms of joint kinematics in lower-limb body. The height of chairs was also considered as a design factor. Obese people had a difficulty in sit-to-stand (STS) tasks compared to the non-obese people. High chair heights can make STS task easy and it helps the obese to be more comfortable with STS task in particular. Subjects were instructed to wear inertial measurement unit (IMU) sensors. They perform STS task using chairs of different heights. Joint kinematics and subjective ratings of discomfort were measured. Knee angles of the obese group were greater than that of the non-obese group in normal type. No significant difference in joint kinematics was found in high chair. Interaction effect was found between obesity and height of chair. The results verified the previous research that had suggested a biomechanical model of STS movement. The results can be applied to occupational design for the obese.Keywords: biomechanics, electromyography, joint kinematics, obesity, sitting, sit-to-stand
Procedia PDF Downloads 3021040 Fatigue Life Estimation of Tubular Joints - A Comparative Study
Authors: Jeron Maheswaran, Sudath C. Siriwardane
Abstract:
In fatigue analysis, the structural detail of tubular joint has taken great attention among engineers. The DNV-RP-C203 is covering this topic quite well for simple and clear joint cases. For complex joint and geometry, where joint classification isn’t available and limitation on validity range of non-dimensional geometric parameters, the challenges become a fact among engineers. The classification of joint is important to carry out through the fatigue analysis. These joint configurations are identified by the connectivity and the load distribution of tubular joints. To overcome these problems to some extent, this paper compare the fatigue life of tubular joints in offshore jacket according to the stress concentration factors (SCF) in DNV-RP-C203 and finite element method employed Abaqus/CAE. The paper presents the geometric details, material properties and considered load history of the jacket structure. Describe the global structural analysis and identification of critical tubular joints for fatigue life estimation. Hence fatigue life is determined based on the guidelines provided by design codes. Fatigue analysis of tubular joints is conducted using finite element employed Abaqus/CAE [4] as next major step. Finally, obtained SCFs and fatigue lives are compared and their significances are discussed.Keywords: fatigue life, stress-concentration factor, finite element analysis, offshore jacket structure
Procedia PDF Downloads 4531039 Investigation of Distortion and Impact Strength of 304L Butt Joint Using Different Weld Groove
Authors: A. Sharma, S. S. Sandhu, A. Shahi, A. Kumar
Abstract:
The aim of present investigation was to carry out Finite element modeling of distortion in the case of butt weld. 12mm thick AISI 304L plates were butt welded using three different combinations of groove design namely Double U, Double V and Composite. A full simulation of shielded metal arc welding (SMAW) of nonlinear heat transfer is carried out. Aspects like, temperature-dependent thermal properties of AISI stainless steel above liquid phase, the effect of thermal boundary conditions, were included in the model. Since welding heat dissipation characteristics changed due to variable groove design significant changes in the microhardness tensile strength and impact toughness of the joints were observed. The cumulative distortion was found to be least in double V joint followed by the Composite and Double U-joints. All the joints have joint efficiency more than 100%. CVN value of the Double V-groove weld metal was highest. The experimental results and the FEM results were compared and reveal a very good correlation for distortion and weld groove design for a multipass joint with a standard analogy of 83%.Keywords: AISI 304 L, Butt joint, distortion, FEM, groove design, SMAW
Procedia PDF Downloads 4051038 Developing Models for Predicting Physiologically Impaired Arm Reaching Paths
Authors: Nina Robson, Kenneth John Faller II, Vishalkumar Ahir, Mustafa Mhawesh, Reza Langari
Abstract:
This paper describes the development of a model of an impaired human arm performing a reaching motion, which will be used to predict hand path trajectories for people with reduced arm joint mobility. Assuming that the arm was in contact with a surface during the entire movement, the contact conditions at the initial and final task locations were determined and used to generate the entire trajectory. The model was validated by comparing it to experimental data, which simulated an arm joint impairment by physically constraining the joint motion with a brace. Future research will include using the model in the development of physical training protocols that avoid early recruitment of “healthy” Degrees-Of-Freedom (DOF) for reaching motions, thus facilitating an Active Range-Of-Motion Recovery (AROM) for a particular impaired joint.Keywords: higher order kinematic specifications, human motor coordination, impaired movement, kinematic synthesis
Procedia PDF Downloads 3381037 Joint Modeling of Longitudinal and Time-To-Event Data with Latent Variable
Authors: Xinyuan Y. Song, Kai Kang
Abstract:
Joint models for analyzing longitudinal and survival data are widely used to investigate the relationship between a failure time process and time-variant predictors. A common assumption in conventional joint models in the survival analysis literature is that all predictors are observable. However, this assumption may not always be supported because unobservable traits, namely, latent variables, which are indirectly observable and should be measured through multiple observed variables, are commonly encountered in the medical, behavioral, and financial research settings. In this study, a joint modeling approach to deal with this feature is proposed. The proposed model comprises three parts. The first part is a dynamic factor analysis model for characterizing latent variables through multiple observed indicators over time. The second part is a random coefficient trajectory model for describing the individual trajectories of latent variables. The third part is a proportional hazard model for examining the effects of time-invariant predictors and the longitudinal trajectories of time-variant latent risk factors on hazards of interest. A Bayesian approach coupled with a Markov chain Monte Carlo algorithm to perform statistical inference. An application of the proposed joint model to a study on the Alzheimer's disease neuroimaging Initiative is presented.Keywords: Bayesian analysis, joint model, longitudinal data, time-to-event data
Procedia PDF Downloads 1431036 Detailed Observations on Numerically Invariant Signatures
Authors: Reza Aghayan
Abstract:
Numerically invariant signatures were introduced as a new paradigm of the invariant recognition for visual objects modulo a certain group of transformations. This paper shows that the current formulation suffers from noise and indeterminacy in the resulting joint group-signatures and applies the n-difference technique and the m-mean signature method to minimize their effects. In our experimental results of applying the proposed numerical scheme to generate joint group-invariant signatures, the sensitivity of some parameters such as regularity and mesh resolution used in the algorithm will also be examined. Finally, several interesting observations are made.Keywords: Euclidean and affine geometry, differential invariant G-signature curves, numerically invariant joint G-signatures, object recognition, noise, indeterminacy
Procedia PDF Downloads 3981035 Assessment of the Impact of the Application of Kinesiology Taping on Joint Position Sense in Knee Joint
Authors: Anna Słupik, Patryk Wąsowski, Anna Mosiołek, Dariusz Białoszewski
Abstract:
Introduction: Kinesiology Taping is one of the most popular techniques used for treatment and supporting physiological processes in sports medicine and physiotherapy. Often it is used to sensorimotor skills of lower limbs by athletes. The aim of the study was to determine the effect of the application of muscle Kinesiology Taping to feel the position setting in motion the joint active. Material and methods: The study involved 50 healthy people between 18 and 30 years of age, 30 men and 20 women (mean age 23.24 years). The participants were divided into two groups. The study group was qualified for Kinesiology Taping application (muscle application, type Y, for quadriceps femoris muscle), while the remaining people used the application made of plaster (placebo group). Testing was performed prior to applying taping, with the applied application (after 30 minutes), then 24 hours after wearing, and after removing the tape. Each evaluated joint position sense - Error of Active Reproduction of Joint Position. Results: The survey revealed no significant differences in measurement between the study group and the placebo group (p> 0.05). No significant differences in time taking into account all four measurements in the group with the applied CT application, which was supported by pairs (p> 0.05). Also in the placebo group showed no significant differences over time (p> 0.05). There was no significant difference between the errors committed in the direction of flexion and extension. Conclusions: 1. Application muscle Kinesiology Taping had no significant effect on the knee joint proprioception. Its use in order to improve sensorimotor seems therefore unjustified. 2. There are no differences between applications Kinesiology Taping and placebo indicates that the clinical effect of stretch tape is minimal or absent. 3. The results are the basis for the continuation of prospective, randomized trials of numerous and study group.Keywords: joint position sense, kinesiology taping, knee joint, proprioception
Procedia PDF Downloads 4031034 The Parental Involvement as Predictor of Happiness in School-Aged Children
Authors: Giedre Sirvinskiene, Kastytis Smigelskas
Abstract:
Quality of family relations is an important factor of child development, however, the role of joint family activities on adolescent happiness still needs investigation. The aim of this study is to analyze associations between happiness of school-aged children and parental involvement. The analysis involves Lithuanian data from the cross-sectional Health Behaviour in School Aged Children (HBSC) study. The sample comprised 5730 children aged 11–15 years. Results: The odds of happiness was 2.38 times higher if children were living together with mother (95% CI: 1.81–3.13) and 1.81 times – with father (95% CI: 1.53–2.15). However, the likelihood of happiness was 7.21 times lower if adolescent had difficulties to talk with mother (95% CI: 5.42–9.61) and 6.40 times – with father (95% CI: 4.80–8.56). The joint daily adolescents-parents activities also predict the odds for happiness: joint TV watching by 5.96 times (95% CI: 4.21–8.43), having meals together by 7.02 times (95% CI: 4.77–10.32), going for a walk together 4.30 times (95% CI: 2.96–6.26), visiting places by 6.85 times (95% CI: 4.74–9.90), visiting friends and relatives by 7.13 times (95% CI: 4.87–10.43), sporting by 2.76 (95% CI: 1.83–4.18) as well as discussing various things by 7.35 times (95% CI: 5.50–9.82). Conclusions: Joint parents-adolescents activities and communication are related with greater happiness of adolescent. Though adolescence is a period when the relationships with peers get more importance, the communication and joint activities with parents remain a significant factor of adolescent happiness.Keywords: adolescent, family, happiness, school-age
Procedia PDF Downloads 2511033 Performance Evaluations of Lap Spliced Joint of Decked Bulb-Tee Type Modular Bridge
Authors: Sang-Yoon Lee, Jae-Joon Song
Abstract:
Precast decked bulb-tee girder or precast deck generally adopts in-situ connections of loop joints. Loop joint could be an effective method to connect precast concrete members where the width of joint is not wide sufficiently to allow the lap splice length of reinforcing bars. However, the regulation for the minimum bend diameter of looped rebar gives limitation not to reduce the thickness of precast concrete member; thus, in-situ connection adopting loop joint place a constraint on improving the structural efficiency of precast concrete member. Ultra high strength concrete (UHSC) is effective on reduce the development and lap splice length of reinforcing bar. In-situ connection with UHSC gives a merit to reduce connection width. This study intends to investigate the details of the longitudinal joint to be applied in the precast modular bridge using decked bulb-tee girder that has been recently developed in Korea. This paper presents the details applying UHSC and lap splices of straight reinforcement and results of tests. Several tests were performed on flexural specimens with longitudinal joints to verify the length of the lap splices and amount of transverse reinforcement, and to examine the flexural strength of the longitudinal joint.Keywords: precast structure, decked bulb-tee girder, in-situ connection, UHSC, modular bridge
Procedia PDF Downloads 4611032 Localisation of Fluorescently Labelled Drug-Free Phospholipid Vesicles to the Cartilage Surface of Rat Synovial Joints
Authors: Sam Yurdakul, Nick Baverstock, Jim Mills
Abstract:
TDT 064 (FLEXISEQ®) is a drug-free gel used to treat osteoarthritis (OA)-associated pain and joint stiffness. It contains ultra-deformable phospholipid Sequessome™ vesicles, which can pass through the skin barrier intact. In six randomized OA studies, topical TDT 064 was well tolerated and improved joint pain, physical function and stiffness. In the largest study, these TDT 064-mediated effects were statistically significantly greater than oral placebo and equivalent to celecoxib. To understand the therapeutic effects of TDT 064, we investigated the localisation of the drug-free vesicles within rat synovial joints. TDT 064 containing DiO-labelled Sequessome™ vesicles was applied to the knees of four 6-week-old CD® hairless rats (10 mg/kg/ joint), 2–3 times/day, for 3 days (representing the recommended clinical dose). Eighteen hours later, the animals and one untreated control were sacrificed, and the knee joints isolated, flash frozen and embedded in Acrytol Mounting Media™. Approximately 15 sections (10 µm) from each joint were analysed by fluorescence microscopy. To investigate whether the localisation of DiO fluorescence was associated with intact vesicles, an anti-PEG monoclonal antibody (mAb) was used to detect Tween, a constituent of Sequessome™ vesicles. Sections were visualized at 484 nm (DiO) and 647 nm (anti-PEG mAb) and analysed using inForm 1.4 (Perkin Elmer, Inc.). Significant fluorescence was observed at 484 nm in sections from TDT 064-treated animals. No non-specific fluorescence was observed in control sections. Fluorescence was detected as discrete vesicles on the cartilage surfaces, inside the cartilaginous matrix and within the synovial space. The number of DiO-labelled vesicles in multiple fields of view was consistent and >100 in sections from four different treated knees. DiO and anti-PEG mAb co-localised within the collagenous tissues in four different joint sections. Under higher magnification (40x), vesicles were seen in the intercellular spaces of the synovial joint tissue, but no fluorescence was seen inside cells. These data suggest that the phospholipid vesicles in TDT 064 localize at the surface of the joint cartilage; these vesicles may therefore be supplementing the phospholipid deficiency reported in OA and acting as a biolubricant within the synovial joint.Keywords: joint pain, osteoarthritis, phospholipid vesicles, TDT 064
Procedia PDF Downloads 4431031 Quantification of Dowel-Concrete Interaction in Jointed Plain Concrete Pavements Using 3D Numerical Simulation
Authors: Lakshmana Ravi Raj Gali, K. Sridhar Reddy, M. Amaranatha Reddy
Abstract:
Load transfer between adjacent slabs of the jointed plain concrete pavement (JPCP) system is inevitable for long-lasting performance. Dowel bars are generally used to ensure sufficient degree of load transfer, in addition to the load transferred by aggregate interlock mechanism at the joints. Joint efficiency is the measure of joint quality, a major concern and therefore the dowel bar system should be designed and constructed well. The interaction between dowel bars and concrete that includes various parameters of dowel bar and concrete will explain the degree of joint efficiency. The present study focuses on the methodology of selecting contact stiffness, which quantifies dowel-concrete interaction. In addition, a parametric study which focuses on the effect of dowel diameter, dowel shape, the spacing between dowel bars, joint opening, the thickness of the slab, the elastic modulus of concrete, and concrete cover on contact stiffness was also performed. The results indicated that the thickness of the slab is most critical among various parameters to explain the joint efficiency. Further displacement equivalency method was proposed to find out the contact stiffness. The proposed methodology was validated with the available field surface deflection data collected by falling weight deflectometer (FWD).Keywords: contact stiffness, displacement equivalency method, Dowel-concrete interaction, joint behavior, 3D numerical simulation
Procedia PDF Downloads 1511030 Analysis of Joint Source Channel LDPC Coding for Correlated Sources Transmission over Noisy Channels
Authors: Marwa Ben Abdessalem, Amin Zribi, Ammar Bouallègue
Abstract:
In this paper, a Joint Source Channel coding scheme based on LDPC codes is investigated. We consider two concatenated LDPC codes, one allows to compress a correlated source and the second to protect it against channel degradations. The original information can be reconstructed at the receiver by a joint decoder, where the source decoder and the channel decoder run in parallel by transferring extrinsic information. We investigate the performance of the JSC LDPC code in terms of Bit-Error Rate (BER) in the case of transmission over an Additive White Gaussian Noise (AWGN) channel, and for different source and channel rate parameters. We emphasize how JSC LDPC presents a performance tradeoff depending on the channel state and on the source correlation. We show that, the JSC LDPC is an efficient solution for a relatively low Signal-to-Noise Ratio (SNR) channel, especially with highly correlated sources. Finally, a source-channel rate optimization has to be applied to guarantee the best JSC LDPC system performance for a given channel.Keywords: AWGN channel, belief propagation, joint source channel coding, LDPC codes
Procedia PDF Downloads 3571029 Reliability of Dissimilar Metal Soldered Joint in Fabrication of Electromagnetic Interference Shielded Door Frame
Authors: Rehan Waheed, Hasan Aftab Saeed, Wasim Tarar, Khalid Mahmood, Sajid Ullah Butt
Abstract:
Electromagnetic Interference (EMI) shielded doors made from brass extruded channels need to be welded with shielded enclosures to attain optimum shielding performance. Control of welding induced distortion is a problem in welding dissimilar metals like steel and brass. In this research, soldering of the steel-brass joint has been proposed to avoid weld distortion. The material used for brass channel is UNS C36000. The thickness of brass is defined by the manufacturing process, i.e. extrusion. The thickness of shielded enclosure material (ASTM A36) can be varied to produce joint between the dissimilar metals. Steel sections of different gauges are soldered using (91% tin, 9% zinc) solder to the brass, and strength of joint is measured by standard test procedures. It is observed that thin steel sheets produce a stronger bond with brass. The steel sections further require to be welded with shielded enclosure steel sheets through TIG welding process. Stresses and deformation in the vicinity of soldered portion is calculated through FE simulation. Crack formation in soldered area is also studied through experimental work. It has been found that in thin sheets deformation produced due to applied force is localized and has no effect on soldered joint area whereas in thick sheets profound cracks have been observed in soldered joint. The shielding effectiveness of EMI shielded door is compromised due to these cracks. The shielding effectiveness of the specimens is tested and results are compared.Keywords: dissimilar metal, EMI shielding, joint strength, soldering
Procedia PDF Downloads 1631028 Effect of Laser Input Energy on the Laser Joining of Polyethylene Terephthalate to Titanium
Authors: Y. J. Chen, T. M. Yue, Z. N. Guo
Abstract:
This paper reports the effects of laser energy on the characteristics of bubbles generated in the weld zone and the formation of new chemical bonds at the Polyethylene Terephthalate (PET)/Ti joint interface in laser joining of PET to Ti. The samples were produced by using different laser energies ranging from 1.5 J – 6 J in steps of 1.5 J, while all other joining parameters remained unchanged. The types of chemical bonding at the joint interface were analysed by the x-ray photoelectron spectroscopy (XPS) depth-profiling method. The results show that the characteristics of the bubbles and the thickness of the chemically bonded interface, which contains the laser generated bonds of Ti–C and Ti–O, increase markedly with increasing laser energy input. The tensile failure load of the joint depends on the combined effect of the amount and distribution of the bubbles formed and the chemical bonding intensity of the joint interface.Keywords: laser direct joining, Ti/PET interface, laser energy, XPS depth profiling, chemical bond, tensile failure load
Procedia PDF Downloads 2111027 Study the Difference Between the Mohr-Coulomb and the Barton-Bandis Joint Constitutive Models: A Case Study from the Iron Open Pit Mine, Canada
Authors: Abbas Kamalibandpey, Alain Beland, Joseph Mukendi Kabuya
Abstract:
Since a rock mass is a discontinuum medium, its behaviour is governed by discontinuities such as faults, joint sets, lithologic contact, and bedding planes. Thus, rock slope stability analysis in jointed rock masses is largely dependent upon discontinuities constitutive equations. This paper studies the difference between the Mohr-Coulomb (MC) and the Barton-Bandis (BB) joint constitutive numerical models for lithological contacts and joint sets. For the rock in these models, generalized Hoek-Brown criteria have been considered. The joint roughness coefficient (JRC) and the joint wall compressive strength (JCS) are vital parameters in the BB model. The numerical models are applied to the rock slope stability analysis in the Mont-Wright (MW) mine. The Mont-Wright mine is owned and operated by ArcelorMittal Mining Canada (AMMC), one of the largest iron-ore open pit operations in Canada. In this regard, one of the high walls of the mine has been selected to undergo slope stability analysis with RS2D software, finite element method. Three piezometers have been installed in this zone to record pore water pressure and it is monitored by radar. In this zone, the AMP-IF and QRMS-IF contacts and very persistent and altered joint sets in IF control the rock slope behaviour. The height of the slope is more than 250 m and consists of different lithologies such as AMP, IF, GN, QRMS, and QR. To apply the B-B model, the joint sets and geological contacts have been scanned by Maptek, and their JRC has been calculated by different methods. The numerical studies reveal that the JRC of geological contacts, AMP-IF and QRMS-IF, and joint sets in IF had a significant influence on the safety factor. After evaluating the results of rock slope stability analysis and the radar data, the B-B constitutive equation for discontinuities has shown acceptable results to the real condition in the mine. It should be noted that the difference in safety factors in MC and BB joint constitutive models in some cases is more than 30%.Keywords: barton-Bandis criterion, Hoek-brown and Mohr-Coulomb criteria, open pit, slope stability
Procedia PDF Downloads 1031026 Numerical Investigation on Optimizing Fatigue Life in a Lap Joint Structure
Authors: P. Zamani, S. Mohajerzadeh, R. Masoudinejad, K. Farhangdoost
Abstract:
The riveting process is one of the important ways to keep fastening the lap joints in aircraft structures. Failure of aircraft lap joints directly depends on the stress field in the joint. An important application of riveting process is in the construction of aircraft fuselage structures. In this paper, a 3D finite element method is carried out in order to optimize residual stress field in a riveted lap joint and also to estimate its fatigue life. In continue, a number of experiments are designed and analyzed using design of experiments (DOE). Then, Taguchi method is used to select an optimized case between different levels of each factor. Besides that, the factor which affects the most on residual stress field is investigated. Such optimized case provides the maximum residual stress field. Fatigue life of the optimized joint is estimated by Paris-Erdogan law. Stress intensity factors (SIFs) are calculated using both finite element analysis and experimental formula. In addition, the effect of residual stress field, geometry, and secondary bending are considered in SIF calculation. A good agreement is found between results of such methods. Comparison between optimized fatigue life and fatigue life of other joints has shown an improvement in the joint’s life.Keywords: fatigue life, residual stress, riveting process, stress intensity factor, Taguchi method
Procedia PDF Downloads 4521025 Joint Simulation and Estimation for Geometallurgical Modeling of Crushing Consumption Energy in the Mineral Processing Plants
Authors: Farzaneh Khorram, Xavier Emery
Abstract:
In this paper, it is aimed to create a crushing consumption energy (CCE) block model and determine the blocks with the potential to have the maximum grinding process energy consumption for the study area. For this purpose, a joint estimate (co-kriging) and joint simulation (turning band method and plurigaussian methods) to predict the CCE based on its correlation with SAG power index (SPI), A×B, and ball mill bond work Index (BWI). The analysis shows that TBCOSIM and plurigaussian have the more realistic results compared to cokriging. It seems logical due to the nature of the data geometallurgical and the linearity of the kriging method and the smoothing effect of kriging.Keywords: plurigaussian, turning band, cokriging, geometallurgy
Procedia PDF Downloads 69