Search results for: antenatal monitoring
3207 Analysis of Trends in Equity of Maternal Health Care in South India
Authors: Anushree S. Panikkassery
Abstract:
The paper analyses the pattern and trend of maternal health care in south Indian states. It studies the interstate disparities in terms of maternal health care. It also compares the trends in terms of achieving the target of sustainable development Goal is related to maternal health. The maternal health care (MHC) development is one of the key indicators for the development of health sector in the country and assumes significance from the socioeconomic and developmental perspectives. Maternal health care mainly consists of composite care during pregnancy, child birth as well as postpartum period. Antenatal care, identification, referral and management of high risk pregnancies, safe and healthy child birth and early postnatal care are some of the important issues pertaining to maternal health. Data is collected from national family health survey 1992-93, 1998-99, 2005-06, and 2015-16. A concentration index is used to study the disparities in equity of maternal health among south Indian states. The study shows that there has been an improvement in maternal health care in south Indian states with Kerala topping among the states. But there exist disparities among the south Indian states.Keywords: antenatal care, disparities, equity, maternal health
Procedia PDF Downloads 3833206 Foot Self-Monitoring Knowledge, Attitude, Practice, and Related Factors among Diabetic Patients: A Descriptive and Correlational Study in a Taiwan Teaching Hospital
Authors: Li-Ching Lin, Yu-Tzu Dai
Abstract:
Recurrent foot ulcers or foot amputation have a major impact on patients with diabetes mellitus (DM), medical professionals, and society. A critical procedure for foot care is foot self-monitoring. Medical professionals’ understanding of patients’ foot self-monitoring knowledge, attitude, and practice is beneficial for raising patients’ disease awareness. This study investigated these and related factors among patients with DM through a descriptive study of the correlations. A scale for measuring the foot self-monitoring knowledge, attitude, and practice of patients with DM was used. Purposive sampling was adopted, and 100 samples were collected from the respondents’ self-reports or from interviews. The statistical methods employed were an independent-sample t-test, one-way analysis of variance, Pearson correlation coefficient, and multivariate regression analysis. The findings were as follows: the respondents scored an average of 12.97 on foot self-monitoring knowledge, and the correct answer rate was 68.26%. The respondents performed relatively lower in foot health screenings and recording, and awareness of neuropathy in the foot. The respondents held a positive attitude toward self-monitoring their feet and a negative attitude toward having others check the soles of their feet. The respondents scored an average of 12.64 on foot self-monitoring practice. Their scores were lower in their frequency of self-monitoring their feet, recording their self-monitoring results, checking their pedal pulse, and examining if their soles were red immediately after taking off their shoes. Significant positive correlations were observed among foot self-monitoring knowledge, attitude, and practice. The correlation coefficient between self-monitoring knowledge and self-monitoring practice was 0.20, and that between self-monitoring attitude and self-monitoring practice was 0.44. Stepwise regression analysis revealed that the main predictive factors of the foot self-monitoring practice in patients with DM were foot self-monitoring attitude, prior experience in foot care, and an educational attainment of college or higher. These factors predicted 33% of the variance. This study concludes that patients with DM lacked foot self-monitoring practice and advises that the patients’ self-monitoring abilities be evaluated first, including whether patients have poor eyesight, difficulties in bending forward due to obesity, and people who can assist them in self-monitoring. In addition, patient education should emphasize self-monitoring knowledge and practice, such as perceptions regarding the symptoms of foot neurovascular lesions, pulse monitoring methods, and new foot self-monitoring equipment. By doing so, new or recurring ulcers may be discovered in their early stages.Keywords: diabetic foot, foot self-monitoring attitude, foot self-monitoring knowledge, foot self-monitoring practice
Procedia PDF Downloads 1963205 Implementation of Clinical Monitoring System of Physiological Parameters
Authors: Abdesselam Babouri, Ahcène Lemzadmi, M Rahmane, B. Belhadi, N. Abouchi
Abstract:
Medical monitoring aims at monitoring and remotely controlling the vital physiological parameters of the patient. The physiological sensors provide repetitive measurements of these parameters in the form of electrical signals that vary continuously over time. Various measures allow informing us about the health of the person's physiological data (weight, blood pressure, heart rate or specific to a disease), environmental conditions (temperature, humidity, light, noise level) and displacement and movements (physical efforts and the completion of major daily living activities). The collected data will allow monitoring the patient’s condition and alerting in case of modification. They are also used in the diagnosis and decision making on medical treatment and the health of the patient. This work presents the implementation of a monitoring system to be used for the control of physiological parameters.Keywords: clinical monitoring, physiological parameters, biomedical sensors, personal health
Procedia PDF Downloads 4733204 Tele-Monitoring and Logging of Patient Health Parameters Using Zigbee
Authors: Kirubasankar, Sanjeevkumar, Aravindh Nagappan
Abstract:
This paper addresses a system for monitoring patients using biomedical sensors and displaying it in a remote place. The main challenges in present health monitoring devices are lack of remote monitoring and logging for future evaluation. Typical instruments used for health parameter measurement provide basic information regarding health status. This paper identifies a set of design principles to address these challenges. This system includes continuous measurement of health parameters such as Heart rate, electrocardiogram, SpO2 level and Body temperature. The accumulated sensor data is relayed to a processing device using a transceiver and viewed by the implementation of cloud services.Keywords: bio-medical sensors, monitoring, logging, cloud service
Procedia PDF Downloads 5203203 Optimization of Monitoring Networks for Air Quality Management in Urban Hotspots
Authors: Vethathirri Ramanujam Srinivasan, S. M. Shiva Nagendra
Abstract:
Air quality management in urban areas is a serious concern in both developed and developing countries. In this regard, more number of air quality monitoring stations are planned to mitigate air pollution in urban areas. In India, Central Pollution Control Board has set up 574 air quality monitoring stations across the country and proposed to set up another 500 stations in the next few years. The number of monitoring stations for each city has been decided based on population data. The setting up of ambient air quality monitoring stations and their operation and maintenance are highly expensive. Therefore, there is a need to optimize monitoring networks for air quality management. The present paper discusses the various methods such as Indian Standards (IS) method, US EPA method and European Union (EU) method to arrive at the minimum number of air quality monitoring stations. In addition, optimization of rain-gauge method and Inverse Distance Weighted (IDW) method using Geographical Information System (GIS) are also explored in the present work for the design of air quality network in Chennai city. In summary, additionally 18 stations are required for Chennai city, and the potential monitoring locations with their corresponding land use patterns are ranked and identified from the 1km x 1km sized grids.Keywords: air quality monitoring network, inverse distance weighted method, population based method, spatial variation
Procedia PDF Downloads 1893202 Design and Implementation of a Monitoring System Using Arduino and MATLAB
Authors: Jonas P. Reges, Jessyca A. Bessa, Auzuir R. Alexandria
Abstract:
The research came up with the need of monitoring them of temperature and relative moisture in past work that enveloped the study of a greenhouse located in the Research and Extension Unit(UEPE). This research brought several unknowns that were resolved from bibliographical research. Based on the studies performed were found some monitoring methods, including the serial communication between the arduino and matlab which showed a great option due to the low cost. The project was conducted in two stages, the first, an algorithm was developed to the Arduino and Matlab, and second, the circuits were assembled and performed the monitoring tests the following variables: moisture, temperature, and distance. During testing it was possible to momentarily observe the change in the levels of monitored variables. The project showed satisfactory results, such as: real-time verification of the change of state variables, the low cost of acquisition of the prototype, possibility of easy change of programming for the execution of monitoring of other variables. Therefore, the project showed the possibility of monitoring through software and hardware that have easy programming and can be used in several areas. However, it is observed also the possibility of improving the project from a remote monitoring via Bluetooth or web server and through the control of monitored variables.Keywords: automation, monitoring, programming, arduino, matlab
Procedia PDF Downloads 5153201 Remote Wireless Patient Monitoring System
Authors: Sagar R. Patil, Dinesh R. Gawade, Sudhir N. Divekar
Abstract:
One of the medical devices we found when we visit a hospital care unit such device is ‘patient monitoring system’. This device (patient monitoring system) informs doctors and nurses about the patient’s physiological signals. However, this device (patient monitoring system) does not have a remote monitoring capability, which is necessitates constant onsite attendance by support personnel (doctors and nurses). Thus, we have developed a Remote Wireless Patient Monitoring System using some biomedical sensors and Android OS, which is a portable patient monitoring. This device(Remote Wireless Patient Monitoring System) monitors the biomedical signals of patients in real time and sends them to remote stations (doctors and nurse’s android Smartphone and web) for display and with alerts when necessary. Wireless Patient Monitoring System different from conventional device (Patient Monitoring system) in two aspects: First its wireless communication capability allows physiological signals to be monitored remotely and second, it is portable so patients can move while there biomedical signals are being monitor. Wireless Patient Monitoring is also notable because of its implementation. We are integrated four sensors such as pulse oximeter (SPO2), thermometer, respiration, blood pressure (BP), heart rate and electrocardiogram (ECG) in this device (Wireless Patient Monitoring System) and Monitoring and communication applications are implemented on the Android OS using threads, which facilitate the stable and timely manipulation of signals and the appropriate sharing of resources. The biomedical data will be display on android smart phone as well as on web Using web server and database system we can share these physiological signals with remote place medical personnel’s or with any where in the world medical personnel’s. We verified that the multitasking implementation used in the system was suitable for patient monitoring and for other Healthcare applications.Keywords: patient monitoring, wireless patient monitoring, bio-medical signals, physiological signals, embedded system, Android OS, healthcare, pulse oximeter (SPO2), thermometer, respiration, blood pressure (BP), heart rate, electrocardiogram (ECG)
Procedia PDF Downloads 5713200 Quantification Model for Capability Evaluation of Optical-Based in-Situ Monitoring System for Laser Powder Bed Fusion (LPBF) Process
Authors: Song Zhang, Hui Wang, Johannes Henrich Schleifenbaum
Abstract:
Due to the increasing demand for quality assurance and reliability for additive manufacturing, the development of an advanced in-situ monitoring system is required to monitor the process anomalies as input for further process control. Optical-based monitoring systems, such as CMOS cameras and NIR cameras, are proved as effective ways to monitor the geometrical distortion and exceptional thermal distribution. Therefore, many studies and applications are focusing on the availability of the optical-based monitoring system for detecting varied types of defects. However, the capability of the monitoring setup is not quantified. In this study, a quantification model to evaluate the capability of the monitoring setups for the LPBF machine based on acquired monitoring data of a designed test artifact is presented, while the design of the relevant test artifacts is discussed. The monitoring setup is evaluated based on its hardware properties, location of the integration, and light condition. Methodology of data processing to quantify the capacity for each aspect is discussed. The minimal capability of the detectable size of the monitoring set up in the application is estimated by quantifying its resolution and accuracy. The quantification model is validated using a CCD camera-based monitoring system for LPBF machines in the laboratory with different setups. The result shows the model to quantify the monitoring system's performance, which makes the evaluation of monitoring systems with the same concept but different setups possible for the LPBF process and provides the direction to improve the setups.Keywords: data processing, in-situ monitoring, LPBF process, optical system, quantization model, test artifact
Procedia PDF Downloads 1973199 Seroprevalence and Determinants of Toxoplasmosis in Pregnant Women Attending Antenatal Clinic at the University Teaching Hospital, Lusaka, Zambia: A Cross-Sectional Study
Authors: Christiana Frimpong, Mpundu Makasa, Lungowe Sitali, Charles Michelo
Abstract:
Background: Toxoplasmosis is a neglected zoonotic disease which is prevalent among pregnant women especially in Africa. This study aimed to determine the seroprevalence and determinants of the disease among pregnant women attending the antenatal clinic at the University Teaching Hospital (UTH). Method: A cross-sectional study was employed where 411 pregnant women attending the antenatal clinic at UTH were interviewed using closed-ended questionnaires. Their blood was also tested for Toxoplasma gondii IgG and IgM antibodies using the OnSite Toxo IgG/IgM Combo Rapid Test cassettes by CTK Biotech, Inc, USA. Result: The overall seroprevalence of the infection (IgG) was 5.87%. There was no seropositive IgM result. Contact with cats showed 7.81 times the risk of contracting the infection in the pregnant women and being a farmer/being involved in construction work showed 15.5 times likelihood of contracting the infection. Socio-economic status of the pregnant women also presented an inverse relationship (showed association) with the infection graphically. However, though there were indications of the association between contact with cats, employment type as well as the socioeconomic status of the pregnant women with the infection, there was not enough evidence to suggest these factors as significant determining factors of Toxoplasma gondii infection in our study population. Conclusion: There is a low prevalence of Toxoplasma gondii infection among pregnant women in Lusaka, Zambia. Screening for the infection among pregnant women can be done once or twice during pregnancy to help protect both mother and child from the disease. Health promotion among women of child bearing age on the subject is of immense importance in order to help curb the situation. Further studies especially that of case-control and cohort studies should be carried out in the country in order to better ascertain the extent of the condition nationwide.Keywords: determinants, pregnant women, seroprevalence, toxoplasmosis, University Teaching Hospital (UTH), Zambia
Procedia PDF Downloads 2323198 The Monitoring of Surface Water Bodies from Tisa Catchment Area, Maramureş County in 2014
Authors: Gabriela-Andreea Despescu, Mădălina Mavrodin, Gheorghe Lăzăroiu, S. Nacu, R. Băstinaş
Abstract:
The Monitoring of Surface Water Bodies (Rivers) from Tisa Catchment Area - Maramureş County in 2014. This study is focused on the monitoring and evaluation of river’s water bodies from Maramureş County, using the methodology associated with the EU Water Framework Directive 60/2000. Thus, in the first part are defined the theoretical terms of monitoring activities related to the water bodies’ quality and the specific features of those we can find in the studied area. There are presented the water bodies’ features, quality indicators and the monitoring frequencies for the rivers situated in the Tisa catchment area. The results have shown the actual ecological and chemical state of those water bodies, in relation with the standard values mentioned through the Water Framework Directive.Keywords: monitoring, surveillance, water bodies, quality
Procedia PDF Downloads 2633197 Concept for Determining the Focus of Technology Monitoring Activities
Authors: Guenther Schuh, Christina Koenig, Nico Schoen, Markus Wellensiek
Abstract:
Identification and selection of appropriate product and manufacturing technologies are key factors for competitiveness and market success of technology-based companies. Therefore many companies perform technology intelligence (TI) activities to ensure the identification of evolving technologies at the right time. Technology monitoring is one of the three base activities of TI, besides scanning and scouting. As the technological progress is accelerating, more and more technologies are being developed. Against the background of limited resources it is therefore necessary to focus TI activities. In this paper, we propose a concept for defining appropriate search fields for technology monitoring. This limitation of search space leads to more concentrated monitoring activities. The concept will be introduced and demonstrated through an anonymized case study conducted within an industry project at the Fraunhofer Institute for Production Technology. The described concept provides a customized monitoring approach, which is suitable for use in technology-oriented companies especially those that have not yet defined an explicit technology strategy. It is shown in this paper that the definition of search fields and search tasks are suitable methods to define topics of interest and thus to direct monitoring activities. Current as well as planned product, production and material technologies as well as existing skills, capabilities and resources form the basis of the described derivation of relevant search areas. To further improve the concept of technology monitoring the proposed concept should be extended during future research e.g. by the definition of relevant monitoring parameters.Keywords: monitoring radar, search field, technology intelligence, technology monitoring
Procedia PDF Downloads 4743196 Low-Cost IoT System for Monitoring Ground Propagation Waves due to Construction and Traffic Activities to Nearby Construction
Authors: Lan Nguyen, Kien Le Tan, Bao Nguyen Pham Gia
Abstract:
Due to the high cost, specialized dynamic measurement devices for industrial lands are difficult for many colleges to equip for hands-on teaching. This study connects a dynamic measurement sensor and receiver utilizing an inexpensive Raspberry Pi 4 board, some 24-bit ADC circuits, a geophone vibration sensor, and embedded Python open-source programming. Gather and analyze signals for dynamic measuring, ground vibration monitoring, and structure vibration monitoring. The system may wirelessly communicate data to the computer and is set up as a communication node network, enabling real-time monitoring of background vibrations at various locations. The device can be utilized for a variety of dynamic measurement and monitoring tasks, including monitoring earthquake vibrations, ground vibrations from construction operations, traffic, and vibrations of building structures.Keywords: sensors, FFT, signal processing, real-time data monitoring, ground propagation wave, python, raspberry Pi 4
Procedia PDF Downloads 1033195 Development of a Serial Signal Monitoring Program for Educational Purposes
Authors: Jungho Moon, Lae-Jeong Park
Abstract:
This paper introduces a signal monitoring program developed with a view to helping electrical engineering students get familiar with sensors with digital output. Because the output of digital sensors cannot be simply monitored by a measuring instrument such as an oscilloscope, students tend to have a hard time dealing with digital sensors. The monitoring program runs on a PC and communicates with an MCU that reads the output of digital sensors via an asynchronous communication interface. Receiving the sensor data from the MCU, the monitoring program shows time and/or frequency domain plots of the data in real time. In addition, the monitoring program provides a serial terminal that enables the user to exchange text information with the MCU while the received data is plotted. The user can easily observe the output of digital sensors and configure the digital sensors in real time, which helps students who do not have enough experiences with digital sensors. Though the monitoring program was programmed in the Matlab programming language, it runs without the Matlab since it was compiled as a standalone executable.Keywords: digital sensor, MATLAB, MCU, signal monitoring program
Procedia PDF Downloads 4963194 Health Monitoring of Concrete Assets in Refinery
Authors: Girish M. Bhatia
Abstract:
Most of the important structures in refinery complex are RCC Structures for which in-depth structural monitoring and inspection is required for incessant service. Reinforced concrete structures can be under threat from a combination of insidious challenges due to environmental conditions, including temperature and humidity that lead to accelerated deterioration mechanisms like carbonation, as well as marine exposure, above and below ground structures can experience ingress from aggressive ground waters carrying chlorides and sulphates leading to unexpected deterioration that threaten the integrity of a vital structural asset. By application of health monitoring techniques like corrosion monitoring with help of sensor probes, visual inspection of high rise structures with help of drones, it is possible to establish an early warning at the onset of these destructive processes.Keywords: concrete structures, corrosion sensors, drones, health monitoring
Procedia PDF Downloads 3983193 Remote Patient Monitoring for Covid-19
Authors: Launcelot McGrath
Abstract:
The Coronavirus disease 2019 (COVID-19) has spread rapidly around the world, resulting in high mortality rates and very large numbers of people requiring medical treatment in ICU. Management of patient hospitalisation is a critical aspect to control this disease and reduce chaos in the healthcare systems. Remote monitoring provides a solution to protect vulnerable and elderly high-risk patients. Continuous remote monitoring of oxygen saturation, respiratory rate, heart rate, and temperature, etc., provides medical systems with up-to-the-minute information about their patients' statuses. Remote monitoring also limits the spread of infection by reducing hospital overcrowding. This paper examines the potential of remote monitoring for Covid-19 to assist in the rapid identification of patients at risk, facilitate the detection of patient deterioration, and enable early interventions.Keywords: remote monitoring, patient care, oxygen saturation, Covid-19, hospital management
Procedia PDF Downloads 1083192 Fulfillment of Models of Prenatal Care in Adolescents from Mexico and Chile
Authors: Alejandra Sierra, Gloria Valadez, Adriana Dávalos, Mirliana Ramírez
Abstract:
For years, the Pan American Health Organization/World Health Organization and other organizations have made efforts to the improve access and the quality of prenatal care as part of comprehensive programs for maternal and neonatal health, the standards of care have been renewed in order to migrate from a medical perspective to a holistic perspective. However, despite the efforts currently antenatal care models have not been verified by a scientific evaluation in order to determine their effectiveness. The teenage pregnancy is considered as a very important phenomenon since it has been strongly associated with inequalities, poverty and the lack of gender quality; therefore it is important to analyze the antenatal care that’s been given, including not only the clinical intervention but also the activities surrounding the advertising and the health education. In this study, the objective was to describe if the previously established activities (on the prenatal care models) are being performed in the care of pregnant teenagers attending prenatal care in health institutions in two cities in México and Chile during 2013. Methods: Observational and descriptive study, of a transversal cohort. 170 pregnant women (13-19 years) were included in prenatal care in two health institutions (100 women from León-Mexico and 70 from Chile-Coquimbo). Data collection: direct survey, perinatal clinical record card which was used as checklists: WHO antenatal care model WHO-2003, Official Mexican Standard NOM-007-SSA2-1993 and Personalized Service Manual on Reproductive Process- Chile Crece Contigo; for data analysis descriptive statistics were used. The project was approved by the relevant ethics committees. Results: Regarding the fulfillment of interventions focused on physical, gynecological exam, immunizations, monitoring signs and biochemical parameters in both groups was met by more than 84%; the activities of guidance and counseling pregnant teenagers in Leon compliance rates were below 50%, on the other hand, although pregnant women in Coquimbo had a higher percentage of compliance, no one reached 100%. The topics that less was oriented were: family planning, signs and symptoms of complications and labor. Conclusions: Although the coverage of the interventions indicated in the prenatal care models was high, there were still shortcomings in the fulfillment of activities to orientation, education and health promotion. Deficiencies in adherence to prenatal care guidelines could be due to different circumstances such as lack of registration or incomplete filling of medical records, lack of medical supplies or health personnel, absences of people at prenatal check-up appointments, among many others. Therefore, studies are required to evaluate the quality of prenatal care and the effectiveness of existing models, considering the role of the different actors (pregnant women, professionals and health institutions) involved in the functionality and quality of prenatal care models, in order to create strategies to design or improve the application of a complete process of promotion and prevention of maternal and child health as well as sexual and reproductive health in general.Keywords: adolescent health, health systems, maternal health, primary health care
Procedia PDF Downloads 2053191 Corrosion Monitoring Techniques Impact on Concrete Durability: A Review
Authors: Victor A. Okenyi, Kehinde A. Alawode
Abstract:
Corrosion of reinforcement in concrete structures remains a durability issue in structural engineering with the increasing cost of repair and maintenance. The mechanism and factors influencing reinforcement corrosion in concrete with various electrochemical monitoring techniques including non-destructive, destructive techniques and the roles of sensors have been reviewed with the aim of determining the monitoring technique that proved most effective in determining corrosion parameters and more practicable for the assessment of concrete durability. Electrochemical impedance spectroscopy (EIS) and linear polarization resistance (LPR) techniques showed great performance in evaluating corrosion kinetics and corrosion rate, respectively, while the gravimetric weight loss (GWL) technique provided accurate measurements. However, no single monitoring technique showed to be the ultimate technique, and this calls for more research work in the development of more dynamic monitoring tools capable of considering all possible corrosion factors in the corrosion monitoring process.Keywords: corrosion, concrete structures, durability, non-destructive technique, sensor
Procedia PDF Downloads 1823190 Static and Dynamic Tailings Dam Monitoring with Accelerometers
Authors: Cristiana Ortigão, Antonio Couto, Thiago Gabriel
Abstract:
In the wake of Samarco Fundão’s failure in 2015 followed by Vale’s Brumadinho disaster in 2019, the Brazilian National Mining Agency started a comprehensive dam safety programmed to rank dam safety risks and establish monitoring and analysis procedures. This paper focuses on the use of accelerometers for static and dynamic applications. Static applications may employ tiltmeters, as an example shown later in this paper. Dynamic monitoring of a structure with accelerometers yields its dynamic signature and this technique has also been successfully used in Brazil and this paper gives an example of tailings dam.Keywords: instrumentation, dynamic, monitoring, tailings, dams, tiltmeters, automation
Procedia PDF Downloads 1463189 Monitoring a Membrane Structure Using Non-Destructive Testing
Authors: Gokhan Kilic, Pelin Celik
Abstract:
Structural health monitoring (SHM) is widely used in evaluating the state and health of membrane structures. In the past, in order to collect data and send it to a data collection unit on membrane structures, wire sensors had to be put as part of the SHM process. However, this study recommends using wireless sensors instead of traditional wire ones to construct an economical, useful, and easy-to-install membrane structure health monitoring system. Every wireless sensor uses a software translation program that is connected to the monitoring server. Operational neural networks (ONNs) have recently been developed to solve the shortcomings of convolutional neural networks (CNNs), such as the network's resemblance to the linear neuron model. The results of using ONNs for monitoring to evaluate the structural health of a membrane are presented in this work.Keywords: wireless sensor network, non-destructive testing, operational neural networks, membrane structures, dynamic monitoring
Procedia PDF Downloads 923188 Development of Monitoring Blood Bank Center Based PIC Microcontroller Using CAN Communication
Authors: Kaiwan S. Ismael, Ergun Ercelebi, Majeed Nader
Abstract:
This paper describes the design and implementation of a hardware setup for online monitoring of 24 refrigerators inside blood bank center using the microcontroller and CAN bus for communications between each node. Due to the security of locations in the blood bank hall and difficulty of monitoring of each refrigerator separately, this work proposes a solution to monitor all the blood bank refrigerators in one location. CAN-bus system is used because it has many applications and advantages, especially for this system due to easy in use, low cost, providing a reduction in wiring, fast to repair and easily expanding the project without a problem.Keywords: control area network (CAN), monitoring blood bank center, PIC microcontroller, MPLAB IDE
Procedia PDF Downloads 4833187 Design of Structural Health Monitoring System for a Damaged Reinforced Concrete Bridge
Authors: Muhammad Fawad
Abstract:
Monitoring and structural health assessment are the primary requirements for the performance evaluation of damaged bridges. This paper highlights the case study of a damaged Reinforced Concrete (RC) bridge structure where the Finite element (FE) modelling of this structure was done using the material properties extracted by the in-situ testing. Analysis was carried out to evaluate the bridge damage. On the basis of FE analysis results, this study proposes a proper Structural Health Monitoring (SHM) system that will extend the life cycle of the bridge with minimal repair costs and reduced risk of failure. This system is based on the installation of three different types of sensors: Liquid Levelling sensors (LLS) for measurement of vertical displacement, Distributed Fiber Optic Sensors (DFOS) for crack monitoring, and Weigh in Motion (WIM) devices for monitoring of moving loads on the bridge.Keywords: bridges, reinforced concrete, finite element method, structural health monitoring, sensors
Procedia PDF Downloads 1043186 Smart Monitoring and Control of Tap Changer Using Intelligent Electronic Device
Authors: K. N. Dinesh Babu, M. V. Gopalan, G. R. Manjunatha, R. Ramaprabha, V. Rajini
Abstract:
In this paper, monitoring and control of tap changer mechanism of a transformer implementation in an intelligent electronic device (IED) is discussed. Its been a custom for decades to provide a separate panel for on load tap changer control for monitoring the tap position. However this facility cannot either record or transfer the information to remote control centers. As there is a technology shift towards the smart grid protection and control standards, the need for implementing remote control and monitoring has necessitated the implementation of this feature in numerical relays. This paper deals with the programming, settings and logic implementation which is applicable to both IEC 61850 compatible and non-compatible IEDs thereby eliminating the need for separate tap changer control equipment. The monitoring mechanism has been implemented in a 28MVA, 110 /6.9kV transformer with 16 tap position with GE make T60 IED at Ultratech cement limited Gulbarga, Karnataka and is in successful service.Keywords: transformer protection, tap changer control, tap position monitoring, on load tap changer, intelligent electronic device (IED)
Procedia PDF Downloads 5933185 Cloud Monitoring and Performance Optimization Ensuring High Availability and Security
Authors: Inayat Ur Rehman, Georgia Sakellari
Abstract:
Cloud computing has evolved into a vital technology for businesses, offering scalability, flexibility, and cost-effectiveness. However, maintaining high availability and optimal performance in the cloud is crucial for reliable services. This paper explores the significance of cloud monitoring and performance optimization in sustaining the high availability of cloud-based systems. It discusses diverse monitoring tools, techniques, and best practices for continually assessing the health and performance of cloud resources. The paper also delves into performance optimization strategies, including resource allocation, load balancing, and auto-scaling, to ensure efficient resource utilization and responsiveness. Addressing potential challenges in cloud monitoring and optimization, the paper offers insights into data security and privacy considerations. Through this thorough analysis, the paper aims to underscore the importance of cloud monitoring and performance optimization for ensuring a seamless and highly available cloud computing environment.Keywords: cloud computing, cloud monitoring, performance optimization, high availability
Procedia PDF Downloads 653184 Spectrum of Acute Kidney Injury in Obstetrics
Authors: Seema Chopra, Amandeep Kaur, Vanita Suri, Shalini Gainder, Minakshi Rohilla
Abstract:
Background: Acute kidney injury (AKI) associated with pregnancy is a serious medical complication which can lead to significant maternal as well as perinatal morbidity and mortality. Material and methods: This prospective observational study was carried out in the Obstetrics and Gynaecology department and dialysis unit of Nephrology department of PGIMER, Chandigarh from July 2013 to June 2014. Forty antenatal/postnatal/postabortal patients who fulfilled the AKIN criteria were enrolled in the study. All patients were followed up till 3 months postpartum. Results: Majority of the patients 23/40 (57.5%) with AKI presented in postpartum period, 14/40 (35%) developed AKI in antenatal period, and 3/40 (7.5%) were postabortal. AKI was attributable mostly to sepsis in 11/40 (27.5%) and PPH in 5/40 (12.5%). Hypertension and its complications causing AKI included eclampsia in 5/40 (12.5%) followed by 3/40 (7.5%) as HELLP syndrome and abruption placentae in 2/40(5%) patients. Three patients each (7.5%) had AFLP, TMA, and HEV as the cause of AKI. Renal replacement therapy in the form of hemodialysis was the treatment in majority of them (28 (70%)). After the acute event, 25 (62.5%) had complete recovery of their renal functions at 3 months follow up. Maternal mortality was seen in 25% (n=10) of the study patients. Conclusion: Timely initiation of RRT in patients with AKI associated with pregnancy has a good maternal outcome in the form of complete recovery of renal functions in 62.5% (25/40) of patients.Keywords: AKI, dialysis, hypertension, sepsis, renal parameters
Procedia PDF Downloads 1623183 End to End Monitoring in Oracle Fusion Middleware for Data Verification
Authors: Syed Kashif Ali, Usman Javaid, Abdullah Chohan
Abstract:
In large enterprises multiple departments use different sort of information systems and databases according to their needs. These systems are independent and heterogeneous in nature and sharing information/data between these systems is not an easy task. The usage of middleware technologies have made data sharing between systems very easy. However, monitoring the exchange of data/information for verification purposes between target and source systems is often complex or impossible for maintenance department due to security/access privileges on target and source systems. In this paper, we are intended to present our experience of an end to end data monitoring approach at middle ware level implemented in Oracle BPEL for data verification without any help of monitoring tool.Keywords: service level agreement, SOA, BPEL, oracle fusion middleware, web service monitoring
Procedia PDF Downloads 4803182 Use of In-line Data Analytics and Empirical Model for Early Fault Detection
Authors: Hyun-Woo Cho
Abstract:
Automatic process monitoring schemes are designed to give early warnings for unusual process events or abnormalities as soon as possible. For this end, various techniques have been developed and utilized in various industrial processes. It includes multivariate statistical methods, representation skills in reduced spaces, kernel-based nonlinear techniques, etc. This work presents a nonlinear empirical monitoring scheme for batch type production processes with incomplete process measurement data. While normal operation data are easy to get, unusual fault data occurs infrequently and thus are difficult to collect. In this work, noise filtering steps are added in order to enhance monitoring performance by eliminating irrelevant information of the data. The performance of the monitoring scheme was demonstrated using batch process data. The results showed that the monitoring performance was improved significantly in terms of detection success rate of process fault.Keywords: batch process, monitoring, measurement, kernel method
Procedia PDF Downloads 3233181 Protection Not Punishment: Use of Electronic Monitoring to Reduce the Risk of Cross-Border Parental Child Abduction
Authors: Nazia Yaqub
Abstract:
Globally, the number of cases of international parental child abduction has remained consistent in the past decade despite the legal provision designed to prevent and deter abduction, and so it appears the current legal approach to prevent abduction is lacking. Reflecting on the findings of an empirical study conducted by the author between 2017-19 on parental abduction from the UK, the article considers a solution to the predicament of protecting children at risk of abduction through electronic monitoring. The electronic monitoring of children has negative connotations, particularly in its use in the criminal justice system, yet in the context of family law proceedings, the article considers whether electronic monitoring could serve a protective rather than a punitive purpose. The article reflects on the use of electronic monitoring in parental abduction cases by the Family Courts and examines the ethical considerations of the proposal, drawing on the rights found in the European Convention on Human Rights and the UN Convention on the Rights of the Child.Keywords: law, parental child abduction, electronic monitoring, legal solutions
Procedia PDF Downloads 673180 Flow Conservation Framework for Monitoring Software Defined Networks
Authors: Jesús Antonio Puente Fernández, Luis Javier Garcia Villalba
Abstract:
New trends on streaming videos such as series or films require a high demand of network resources. This fact results in a huge problem within traditional IP networks due to the rigidity of its architecture. In this way, Software Defined Networks (SDN) is a new concept of network architecture that intends to be more flexible and it simplifies the management in networks with respect to the existing ones. These aspects are possible due to the separation of control plane (controller) and data plane (switches). Taking the advantage of this separated control, it is easy to deploy a monitoring tool independent of device vendors since the existing ones are dependent on the installation of specialized and expensive hardware. In this paper, we propose a framework that optimizes the traffic monitoring in SDN networks that decreases the number of monitoring queries to improve the network traffic and also reduces the overload. The performed experiments (with and without the optimization) using a video streaming delivery between two hosts demonstrate the feasibility of our monitoring proposal.Keywords: optimization, monitoring, software defined networking, statistics, query
Procedia PDF Downloads 3313179 Vibration-Based Monitoring of Tensioning Stay Cables of an Extradosed Bridge
Authors: Chun-Chung Chen, Bo-Han Lee, Yu-Chi Sung
Abstract:
Monitoring the status of tensioning force of stay cables is a significant issue for the assessment of structural safety of extradosed bridges. Moreover, it is known that there is a high correlation between the existing tension force and the vibration frequencies of cables. This paper presents the characteristic of frequencies of stay cables of a field extradosed bridge by using vibration-based monitoring methods. The vibration frequencies of each stay cables were measured in stages from the beginning to the completion of bridge construction. The result shows that the vibration frequency variation trend of different lengths of cables at each measured stage is different. The observed feature can help the application of the bridge long-term monitoring system and contribute to the assessment of bridge safety.Keywords: vibration-based method, extradosed bridges, bridge health monitoring, bridge stay cables
Procedia PDF Downloads 1463178 Global Indicators of Successful Remote Monitoring Adoption Applying Diffusion of Innovation Theory
Authors: Danika Tynes
Abstract:
Innovations in technology have implications for sustainable development in health and wellness. Remote monitoring is one innovation for which the evidence-base has grown to support its viability as a quality healthcare delivery adjunct. This research reviews global data on telehealth adoption, in particular, remote monitoring, and the conditions under which its success becomes more likely. System-level indicators were selected to represent four constructs of DoI theory (relative advantage, compatibility, complexity, and observability) and assessed against 5 types of Telehealth (Teleradiology, Teledermatology, Telepathology, Telepsychology, and Remote Monitoring) using ordinal logistic regression. Analyses include data from 84 countries, as extracted from the World Health Organization, World Bank, ICT (Information Communications Technology) Index, and HDI (Human Development Index) datasets. Analyses supported relative advantage and compatibility as the strongest influencers of remote monitoring adoption. Findings from this research may help focus on the allocation of resources, as a sustainability concern, through consideration of systems-level factors that may influence the success of remote monitoring adoption.Keywords: remote monitoring, diffusion of innovation, telehealth, digital health
Procedia PDF Downloads 133