Search results for: CO₂ injection
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 908

Search results for: CO₂ injection

878 Radial Fuel Injection Computational Fluid Dynamics Model for a Compression Ignition Two-Stroke Opposed Piston Engine

Authors: Tytus Tulwin, Rafal Sochaczewski, Ksenia Siadkowska

Abstract:

Designing a new engine requires a large number of different cases to be considered. Especially different injector parameters and combustion chamber geometries. This is essential when developing an engine with unconventional build – compression ignition, two-stroke operating with direct side injection. Computational Fluid Dynamics modelling allows to test those different conditions and seek for the best conditions with correct combustion. This research presents the combustion results for different injector and combustion chamber cases. The shape of combustion chamber is different than for conventional engines as it requires side injection. This completely changes the optimal shape for the given condition compared to standard automotive heart shaped combustion chamber. Because the injection is not symmetrical there is a strong influence of cylinder swirl and piston motion on the injected fuel stream. The results present the fuel injection phenomena allowing to predict the right injection parameters for a maximum combustion efficiency and minimum piston heat loads. Acknowledgement: This work has been realized in the cooperation with The Construction Office of WSK "PZL-KALISZ" S.A." and is part of Grant Agreement No. POIR.01.02.00-00-0002/15 financed by the Polish National Centre for Research and Development.

Keywords: CFD, combustion, injection, opposed piston

Procedia PDF Downloads 275
877 Deep Injection Wells for Flood Prevention and Groundwater Management

Authors: Mohammad R. Jafari, Francois G. Bernardeau

Abstract:

With its arid climate, Qatar experiences low annual rainfall, intense storms, and high evaporation rates. However, the fast-paced rate of infrastructure development in the capital city of Doha has led to recurring instances of surface water flooding as well as rising groundwater levels. Public Work Authority (PWA/ASHGHAL) has implemented an approach to collect and discharge the flood water into a) positive gravity systems; b) Emergency Flooding Area (EFA) – Evaporation, Infiltration or Storage off-site using tankers; and c) Discharge to deep injection wells. As part of the flood prevention scheme, 21 deep injection wells have been constructed to discharge the collected surface and groundwater table in Doha city. These injection wells function as an alternative in localities that do not possess either positive gravity systems or downstream networks that can accommodate additional loads. These injection wells are 400-m deep and are constructed in a complex karstic subsurface condition with large cavities. The injection well system will discharge collected groundwater and storm surface runoff into the permeable Umm Er Radhuma Formation, which is an aquifer present throughout the Persian Gulf Region. The Umm Er Radhuma formation contains saline water that is not being used for water supply. The injection zone is separated by an impervious gypsum formation which acts as a barrier between upper and lower aquifer. State of the art drilling, grouting, and geophysical techniques have been implemented in construction of the wells to assure that the shallow aquifer would not be contaminated and impacted by injected water. Injection and pumping tests were performed to evaluate injection well functionality (injectability). The results of these tests indicated that majority of the wells can accept injection rate of 200 to 300 m3 /h (56 to 83 l/s) under gravity with average value of 250 m3 /h (70 l/s) compared to design value of 50 l/s. This paper presents design and construction process and issues associated with these injection wells, performing injection/pumping tests to determine capacity and effectiveness of the injection wells, the detailed design of collection system and conveying system into the injection wells, and the operation and maintenance process. This system is completed now and is under operation, and therefore, construction of injection wells is an effective option for flood control.

Keywords: deep injection well, flood prevention scheme, geophysical tests, pumping and injection tests, wellhead assembly

Procedia PDF Downloads 120
876 Uniqueness and Repeatability Analysis for Slim Tube Determined Minimum Miscibility Pressure

Authors: Waqar Ahmad Butt, Gholamreza Vakili Nezhaad, Ali Soud Al Bemani, Yahya Al Wahaibi

Abstract:

Miscible gas injection processes as secondary recovery methods can be applied to a huge number of mature reservoirs to improve the trapped oil displacement. Successful miscible gas injection processes require an accurate estimation of the minimum miscibility pressure (MMP) to make injection process feasible, economical, and effective. There are several methods of MMP determination like slim tube approach, vanishing interfacial tension and rising bubble apparatus but slim tube is the deployed experimental technique in this study. Slim tube method is assumed to be non-standardized for MMP determination with respect to both operating procedure and design. Therefore, 25 slim tube runs were being conducted with three different coil lengths (12, 18 and 24 m) of constant diameter using three different injection rates (0.08, 0.1 and 0.15 cc/min) to evaluate uniqueness and repeatability of determined MMP. A trend of decrease in MMP with increase in coil length was found. No unique trend was found between MMP and injection rate. Lowest MMP and highest recovery were observed with highest coil length and lowest injection rate. It shows that slim tube measured MMP does not depend solely on interacting fluids characteristics but also affected by used coil selection and injection rate choice. Therefore, both slim tube design and procedure need to be standardized. It is recommended to use lowest possible injection rate and estimated coil length depending upon the distance between injections and producing wells for accurate and reliable MMP determination.

Keywords: coil length, injection rate, minimum miscibility pressure, multiple contacts miscibility

Procedia PDF Downloads 254
875 Design and Finite Element Analysis of Clamp Cylinder for Capacity Augmentation of Injection Moulding Machine

Authors: Vimal Jasoliya, Purnank Bhatt, Mit Shah

Abstract:

The Injection Moulding is one of the principle methods of conversions of plastics into various end products using a very wide range of plastics materials from commodity plastics to specialty engineering plastics. Injection Moulding Machines are rated as per the tonnage force applied. The work present includes Design & Finite Element Analysis of a structure component of injection moulding machine i.e. clamp cylinder. The work of the project is to upgrade the 1300T clamp cylinder to 1500T clamp cylinder for injection moulding machine. The design of existing clamp cylinder of 1300T is checked. Finite Element analysis is carried out for 1300T clamp cylinder in ANSYS Workbench, and the stress values are compared with acceptance criteria and theoretical calculation. The relation between the clamp cylinder diameter and the tonnage capacity has been derived and verified for 1300T clamp cylinder. The same correlation is used to find out the thickness for 1500T clamp cylinder. The detailed design of 1500T cylinder is carried out based on calculated thickness.

Keywords: clamp cylinder, fatigue analysis, finite element analysis, injection moulding machines

Procedia PDF Downloads 335
874 Thermodynamic Modeling of Methane Injection in Gas-Condensate Reservoir Core: A Case Study

Authors: F. S. Alavi, D. Mowla, F. Esmaeilzadeh

Abstract:

In this paper, the core of Sarkhoon Gas Condensate Reservoir located in the south of Iran was thermodynamically modeled in order to study the natural depletion process and methane injection phenomena for enhanced gas-condensate recovery using the Eclipse 300 compositional simulator. Modeling was performed for three different core lengths with different production and injection flow rates in both vertical and horizontal cases. According to the results, the final condensate in place value in the natural depletion process is approximately independent of the production rate for a given pressure drop. The final condensate in place value is lower in vertical cases compared to horizontal cases. An increase in the injection flow rate leads to a decrease in the percentage of gascondensate recovery. In cores of equal length, gas condensate recovery percent is higher in vertical cases in comparison to horizontal cases. For a constant injection rate, decreasing the core length leads to a decrease in gas condensate recovery.

Keywords: reservoir simulation, methane injection, enhanced condensate recovery, reservoir core, modeling

Procedia PDF Downloads 94
873 Synergistic Effect of Platelet-Rich Plasma with Hyaluronic Acid Injection Following Arthrocentesis to Reduce Pain and Improve Function in Temporomandibular joint (TMJ) Osteoarthritis

Authors: Ayman Hegab

Abstract:

Increasing evidence supports the use of platelet-rich plasma (PRP) combined with hyaluronic acid (HA) for the treatment of knee osteoarthritis, which effectively promotes cartilage repair. This study aimed to determine whether injection of PRP+HA following arthrocentesis reduces pain and improves maximum incisal opening. This was a single-blind, prospective, randomized control study. The patients were selected based on the Hegab classification: Group I: patients treated with arthrocentesis followed by a single PRP injection; Group II (Control): patients treated with arthrocentesis followed by a single HA injection; and Group III: patients treated with arthrocentesis followed by a single PRP+HA combination injection. The primary predictor variable was the medication used for injection. The primary outcome variables were the maximum voluntary mouth opening and pain index scores. The secondary outcome variable was joint sounds. All outcome variables were assessed and compared among the three groups at baseline and at 1-, 3-, 6-, and 12-month intervals. Other variables, including patients’ age and sex, were evaluated in relation to the patient outcomes. Injecting PRP+HA showed statistically significant improvement in the primary and secondary treatment outcomes over PRP or HA injection throughout the study period (P<0.005). Injection of PRP+HA following arthrocentesis had significant long-term clinical efficacy regarding pain relief that was considered the main concern of both the patient and clinician.

Keywords: TMJ, HA, PRP, osteoarthritis

Procedia PDF Downloads 13
872 The Effect of Education on Nurses' Knowledge Level for Ventrogluteal Site Injection: Pilot Study

Authors: Emel Bayraktar, Gulengun Turk

Abstract:

Introduction and Objective: Safe administration of medicines is one of the main responsibilities of nurses. Intramuscular drug administration is among the most common methods used by nurses among all drug applications. This study was carried out in order to determine determine the effect of education given on injection in ventrogluteal area on the level of knowledge of nurses on this subject. Methods: The sample of the study consisted of 20 nurses who agreed to participate in the study between 01 October and 31 December 2019. The research is a pretest-posttest comparative, quasi-experimental type pilot study. The nurses were given a 4-hour training prepared on injection into the ventrogluteal area. The training consisted of two hours of theoretical and two hours of laboratory practice. Before the training and 4 weeks after the training, a questionnaire form containing questions about their knowledge and practices regarding the injection of the ventrogluteal region was applied to the nurses. Results: The average age of the nurses is 26.55 ± 7.60, 35% (n = 7) of them are undergraduate and 30% (n = 6) of them work in intensive care units. Before the training, 35% (n = 7) of the nurses stated that the most frequently used intramuscular injection site was the ventrogluteal area, and 75% (n = 15) stated that the safest area was the rectus femoris muscle. After the training, 55% (n = 11) of the nurses stated that they most frequently used the ventrogluteal area and 100% (n = 20) of them stated that the ventrogluteal area was the safest area. The average score the nurses got from the premises before the training is 14.15 ± 6.63 (min = 0, max = 20), the total score is 184. The average score obtained after the training was determined as 18.69 ± 2.35 (min = 12, max = 20), and the total score was 243. Conclusion: As a result of the research, it was determined that the training given on the injection of ventrogluteal area increased the knowledge level of the nurses. It is recommended to organize in-service trainings for all nurses on the injection of ventrogluteal area.

Keywords: safe injection, knowledge level, nurse, intramuscular injection, ventrogluteal area

Procedia PDF Downloads 212
871 Effect of Synchronization Protocols on Serum Concentrations of Estrogen and Progesterone in Holstein Dairy Heifers

Authors: K. Shafiei, A. Pirestani, G. Ghalamkari, S. Safavipour

Abstract:

Use of GnRH or its agonists to increase conception rates should be based on an understanding of GnRH-induced biological effects on the reproductive-endocrine system. This effect may occur through GnRH-stimulated LH surge stimulating production of progesterone by corpus luteum.the aim of this study was to compare the effects on reproductive efficiency of a luteolytic dose of a synthetic prostaglandin Cloprostenol Sodium versus ainjectable progesterone and Luliberin- A on Follicle estrogen and progesterone levels.In this study, we used45 head of holstein dairy heifersin the three treatments, with 15 replicates per treatment were performed in random groups. all the heifers before the projects is began in two steps injection 3 mL CloprostenolSodium with an interval of 11 days been synchronized and 10 days later, second injection of prostaglandin was conducted after that we started below protocol:Control group (daily sodium chloride serum injection 1 cc), Group B: Day Zero, intramuscular injection of 15 mg Luliberin- A + every other day injection of 3 cc progesterone + day 7, injection of Cloprostenol Sodium+ day 9, injection of 15 mg Luliberin- A.Group C: similar to Grop B + daily injection of progesterone after that blood samples was collected and centrifuged.plasma were analysed by ELISA.the analysis of this study uses SPSS data software package and compared between the mean and LS Means LSD test at 5% significance level was used.The results of this study shows that maximum of progesterone plasma levels were in the control gruop (P ≥ 0.05).Therefore, daily injection of progesterone inhibit the growth CL. the most estrogen levels in plasma were in Group C (P ≥ 0.05) thus it can be concluded, rise in endogenous estrogen concentrations normally stimulates the preovulatory LH release in heifers.

Keywords: Luliberin- A, Cloprostenol Sodium, estrogen, progesterone, dairy heifers

Procedia PDF Downloads 541
870 Optical Heterodyning of Injection-Locked Laser Sources: A Novel Technique for Millimeter-Wave Signal Generation

Authors: Subal Kar, Madhuja Ghosh, Soumik Das, Antara Saha

Abstract:

A novel technique has been developed to generate ultra-stable millimeter-wave signal by optical heterodyning of the output from two slave laser (SL) sources injection-locked to the sidebands of a frequency modulated (FM) master laser (ML). Precise thermal tuning of the SL sources is required to lock the particular slave laser frequency to the desired FM sidebands of the ML. The output signals from the injection-locked SL when coherently heterodyned in a fast response photo detector like high electron mobility transistor (HEMT), extremely stable millimeter-wave signal having very narrow line width can be generated. The scheme may also be used to generate ultra-stable sub-millimeter-wave/terahertz signal.

Keywords: FM sideband injection locking, master-slave injection locking, millimetre-wave signal generation, optical heterodyning

Procedia PDF Downloads 392
869 Study on the Thermal Mixing of Steam and Coolant in the Hybrid Safety Injection Tank

Authors: Sung Uk Ryu, Byoung Gook Jeon, Sung-Jae Yi, Dong-Jin Euh

Abstract:

In such passive safety injection systems in the nuclear power plant as Core Makeup Tank (CMT) and Hybrid Safety Injection Tank, various thermal-hydraulic phenomena including the direct contact condensation of steam and the thermal stratification of coolant occur. These phenomena are also closely related to the performance of the system. Depending on the condensation rate of the steam injected to the tank, the injection of the coolant and pressure equalizing timings of the tank are decided. The steam injected to the tank from the upper nozzle penetrates the coolant and induces a direct contact condensation. In the present study, the direct contact condensation of steam and the thermal mixing between the steam and coolant were examined by using the Particle Image Velocimetry (PIV) technique. Especially, by altering the size of the nozzle from which the steam is injected, the influence of steam injection velocity on the thermal mixing with coolant and condensation shall be comprehended, while also investigating the influence of condensation on the pressure variation inside the tank. Even though the amounts of steam inserted were the same in three different nozzle size conditions, it was found that the velocity of pressure rise becomes lower as the steam injection area decreases. Also, as the steam injection area increases, the thickness of the zone within which the coolant’s temperature decreases. Thereby, the amount of steam condensed by the direct contact condensation also decreases. The results derived from the present study can be utilized for the detailed design of a passive safety injection system, as well as for modeling the direct contact condensation triggered by the steam jet’s penetration into the coolant.

Keywords: passive safety injection systems, steam penetration, direct contact condensation, particle image velocimetry

Procedia PDF Downloads 396
868 Managing Subretinal Bleeds with Intravitreal Aflibercept

Authors: Prachi Abhishek Dave, Abhishek Dave

Abstract:

Purpose: The purpose of this study is to elucidate the role of intravitreal injection Aflibercept in managing complex cases of Wet Age Related Macular Degeneration (ARMD) and the gratifying visual recovery experienced with a minimally invasive procedure. Methods: A 73-year-old gentleman presented with a drop in vision in the left eye for 25 days. On examination, his best corrected visual acuity (BCVA) in the Right eye (OD) was 6/60, and finger counting close to face in the Left eye (OS). On multimodal imaging, he was diagnosed to have a scarred Wet ARMD in OD and an active Wet ARMD with a large subretinal bleed secondary to Wet ARMD in OS. Treatment management options included monotherapy with an Injection Aflibercept or an intravitreal gas injection with tPA followed by Injection Aflibercept. Considering his one-eyed status, the patient decided to go for Aflibercept monotherapy. Results: After 3 monthly injections of injection Aflibercept, the subretinal bleed reduced, the subretinal fluid resolved, and his vision in OS improved to 6/9. He is on a regular follow-up and has not needed any further injections in OS and he maintains 6/9 vision. Conclusions: Conventional treatment guidelines for a large subretinal bleed dictate the use of gas followed by intravitreal Injection Aflibercept. However, gas has its own limitations of causing a rise in intraocular pressure and a transient loss of vision, which is particularly troublesome in one-eyed patients. Injection Aflibercept offers a much safer, less invasive, and elegant treatment option for such patients with equally good or even better visual outcomes.

Keywords: wet ARMD, subretinal bleed, intravitreal injections, aflibercept, EYELEA, intravitreal gas

Procedia PDF Downloads 44
867 An Open-Label Phase I Clinical Study: Safety, Tolerability and Pharmacodynamics of Mutant Collagenase Injection in Adults for Localized Fat Reduction

Authors: Yong Cang

Abstract:

RJV001 is a subcutaneous injection containing mutated recombinant Collagenase H (ColH), leading to disruption of collagen matrix in adipose tissue and programmed cell death of adipocytes. Here we reported our clinical investigation of the safety, tolerance and pharmacodynamics of localized RJV001 injection into healthy human abdominal fat tissues (NCT04821648, Arizona Research Center). Investigate the safety, tolerance and clinical pharmacodynamics of subcutaneous RJV001 in humans. In the dose-escalating study, 18 subjects completed the study, 100% female, 78% white, with a mean age of 42[±9.9]. All three tested dose (0.05, 0.075 and 0.15 mg/injection), up to 30 injections, were safe and well-tolerated. Bruising and tenderness to palpation, mild to moderate, were the most frequent local skin reactions but nearly all resolved within 30 days. Additionally, physician-monitored ultrasound measurement showed that a reduction in abdominal fat tissue thickness was consistently observed in Cohort C (0.075, 0.15 mg/injection, 30injections), with a mean reduction of 7.37 [± 2.020] mm. Based on this clinical study, RJV001 has been advanced to phase II clinical studies. In the dose-escalating study, subcutaneously administered RJV001 was safe and well-tolerated in healthy adults up to 0.15 mg/injection, 30 injections. Fat reduction and adipocytolysis were observed by ultrasound measurements and histological analysis for exploratory purposes.

Keywords: fat reduction, mutant collagenase, clinical trial, subcutaneous injection

Procedia PDF Downloads 110
866 Effect of Wettability Alteration in Low Salt Water Injection Modeling

Authors: H. Vahdani

Abstract:

By the adsorption of polar compounds and/or the deposition of organic material, the wettability of originally water-wet reservoir rock can be altered. The degree of alteration is determined by the interaction of the oil constituents, the mineral surface, and the brine chemistry. Recently improving oil recovery by tuning wettability alteration is believed as a new recovery method. Various researchers have demonstrated that low salt water injection has a significant impact on oil recovery. It has been shown, for instance, that additional oil can be produced from reservoir rock by managing the injection water. Large wettability sensitivity has been observed, indicating that the oil/water capillary pressure profiles play a major role during low saline water injection simulation. Although the exact physics on how this alteration occurs is still a research topic; however, it has been reported that some of its effect can be captured by a relative permeability shift from an oil-wet system to a water-wet system. Modeling of low salt water injection mainly is based on the theory of wettability alteration and is hence strongly dependent on the wettability of the reservoir. In this article, combination of different wettabilities has been simulated and it is observed that the highest recoveries were from the cases were the reservoir initially was water-wet, and the lowest recoveries was from the cases were the reservoir initially was considered oil-wet. However for the cases where the reservoir initially was oil-wet, the effect of low-salinity waterflooding was the largest.

Keywords: low salt water injection, wettability alteration, modelling, relative permeability

Procedia PDF Downloads 499
865 Failure Analysis of the Gasoline Engines Injection System

Authors: Jozef Jurcik, Miroslav Gutten, Milan Sebok, Daniel Korenciak, Jerzy Roj

Abstract:

The paper presents the research results of electronic fuel injection system, which can be used for diagnostics of automotive systems. In the paper is described the construction and operation of a typical fuel injection system and analyzed its electronic part. It has also been proposed method for the detection of the injector malfunction, based on the analysis of differential current or voltage characteristics. In order to detect the fault state, it is needed to use self-learning process, by the use of an appropriate self-learning algorithm.

Keywords: electronic fuel injector, diagnostics, measurement, testing device

Procedia PDF Downloads 553
864 The Effect of Intrathecal Adenosine in Control of Neuropathic Pain after Lumbar Discectomy in One Level

Authors: Dawood Aghamohammadi, Mahmoud Eidi, Alireza Pishgahi, Azam Esmaeilnejad

Abstract:

Adenosine has an analgesic and anti-inflammatory role and its injections are used for peri-operative pain management. We want to study efficacy of intrathecal injection of adenosine for post operative radicular pain after lumbar discectomy. 40 patients with unilevel lumbar discectomy who had radicular lower limb pain were treated by 1000 micrograms of intrathecal injection of adenosine. Pain severity, pain killer consumption per day and sleep quality were assessed during a 3 months follow up period. Radicular pain severity was significantly reduced in 3 month follow-up period in comparison to the baseline (F=19760, DF=2.53, p-value<0.001). Further painkiller medication consumption rate in average during 3 month follow-up period after injection was significantly lower in comparison to baseline (F= 19.244, df= 1.98, p-value<0.001). This study suggests that intrathecal injection of adenosine is a safe method in order to reduce postoperative pain after lumbar discectomy.

Keywords: adenosine, intrathecal injection, discectomy, neuropathic pain

Procedia PDF Downloads 252
863 Numerical Analysis of Engine Performance and Emission of a 2-Stroke Opposed Piston Hydrogen Engine

Authors: Bahamin Bazooyar, Xinyan Wang, Hua Zhao

Abstract:

As a zero-carbon fuel, hydrogen can be used in combustion engines to avoid carbon emissions. This paper numerically investigates the engine performance of a two-stroke opposed piston hydrogen engine by using three-dimensional (3D) Computational Fluid Dynamics (CFD) simulations. The engine displacement is 12.2 cm, and the compression ratio of 39. RANS simulations with the k-ε turbulence model and coupled chemistry combustion models are performed at an engine speed of 4500 rpm and hydrogen flow rate of up to 100 gr/s. In order to model the hydrogen injection process, the hydrogen nozzle was meshed with refined mesh, and injection pressure varied between 100 and 200 bars. In order to optimize the hydrogen combustion process, the injection timing was optimized between 15 before the top dead center and 10. The results showed that the combustion efficiency was mostly influenced by the injection pressures due to its impact on the fuel/air mixing and charge inhomogeneity. Nitrogen oxide (NOₓ) emissions are well correlated with engine peak temperatures, demonstrating that the thermal NO mechanism is dominant under engine conditions. Through the optimization of hydrogen injection timing and pressure, the peak thermal efficiency of 45 and NOx emission of 15 ppm/kWh can be achieved at an injection timing of 350 CA and pressure of 160 bars.

Keywords: engine, hydrogen, diesel, two-stroke, opposed-piston, decarbonisation

Procedia PDF Downloads 14
862 Numerical Simulation of Different Enhanced Oil Recovery (EOR) Scenarios on a Volatile Oil Reservoir

Authors: Soheil Tavakolpour

Abstract:

Enhance Oil Recovery (EOR) can be considered as an undeniable action in reservoirs life period. Different kind of EOR methods are available, but suitable EOR method depends on reservoir properties, like rock and fluid properties. In this paper, we nominated fifth SPE’s Comparative Solution Projects (CSP) for testing different scenarios. We used seven EOR scenarios for this reservoir and we simulated it for 10 years after 2 years production without any injection. The first scenario is waterflooding for whole of the 10 years period. The second scenario is gas injection for ten years. The third scenario is Water-Alternation-Gas (WAG). In the next scenario, water injected for 4 years before starting WAG injection for the next 6 years. In the fifth scenario, water injected after 6 years WAG injection for 4 years. For sixth and last scenarios, all the things are similar to fourth and fifth scenarios, but gas injected instead of water. Results show that fourth scenario was the most efficient method for 10 years EOR, but it resulted very high water production. Fifth scenario was efficient too, with little water production in comparison to the fourth scenario. Gas injection was not economically attractive. In addition to high gas production, it produced less oil in comparison to other scenarios.

Keywords: WAG, SPE’s comparative solution projects, numerical simulation, EOR scenarios

Procedia PDF Downloads 434
861 Prospective Study of the Evaluation of Autologous Blood Injection in the Treatment of Lateral Epicondylitis

Authors: Bheeshma B., Mathivanan N., Manoj Deepak M., Prabhu Thangaraju, K. Venkatachalam

Abstract:

This study involves the effect of autologous blood injection for patients who had degeneration of the origin of extensor carpi radialis brevis which was confirmed radio logically and by ultrasound examination and failed cortisone injections to the lateral epicondylitis. In this prospective longitudinal series involves pre-injection assessment of grip strength, pain, and function, using the patient-rated tennis elbow evaluation. In this study, blood from the contralateral limb is taken and injected into the affected limb with the help of ultrasound guidance and then the patient wore a customized wrist support for five days, after which they were commenced with stretching, strengthening, and massage programme with an occupational therapist. In these patients assessment was done after six months and then finally at 12 months after injection, using the patient-rated tennis elbow evaluation. 50 patients completed the study, showing significant improvement in pain; the worst pain decreased by two to five points out of a 10-point visual analogue for pain. Self-perceived function improved by 11–25 points out of 100. Women showed significant increase in grip, but men did not. Our study thus concludes that autologous blood injection show significant improvement in pain and function in patients with chronic lateral epicondylitis, who did not have relief with cortisone injection.

Keywords: lateral epicondylitis, autologous blood injection, conservative treatment, plasma-rich proteins (PRPs)

Procedia PDF Downloads 430
860 Oil Recovery Study by Low Temperature Carbon Dioxide Injection in High-Pressure High-Temperature Micromodels

Authors: Zakaria Hamdi, Mariyamni Awang

Abstract:

For the past decades, CO2 flooding has been used as a successful method for enhanced oil recovery (EOR). However, high mobility ratio and fingering effect are considered as important drawbacka of this process. Low temperature injection of CO2 into high temperature reservoirs may improve the oil recovery, but simulating multiphase flow in the non-isothermal medium is difficult, and commercial simulators are very unstable in these conditions. Furthermore, to best of authors’ knowledge, no experimental work was done to verify the results of the simulations and to understand the pore-scale process. In this paper, we present results of investigations on injection of low temperature CO2 into a high-pressure high-temperature micromodel with injection temperature range from 34 to 75 °F. Effect of temperature and saturation changes of different fluids are measured in each case. The results prove the proposed method. The injection of CO2 at low temperatures increased the oil recovery in high temperature reservoirs significantly. Also, CO2 rich phases available in the high temperature system can affect the oil recovery through the better sweep of the oil which is initially caused by penetration of LCO2 inside the system. Furthermore, no unfavorable effect was detected using this method. Low temperature CO2 is proposed to be used as early as secondary recovery.

Keywords: enhanced oil recovery, CO₂ flooding, micromodel studies, miscible flooding

Procedia PDF Downloads 353
859 Spray Characteristics of a Urea Injector Chamber to Improve NOx Conversion Efficiency for Diesel Engines Fueled with Biodiesels

Authors: Kazem Bashirnezhad, Seyed Ahmad Kebriyaee, saeed hoseyngholizadeh moghadam

Abstract:

The urea–SCR catalyst system has the advantages of high NOx conversion efficiency and a wide range of operating conditions. The key factors for successful implementation of urea–SCR technology is good mixing of urea (ammonia) and gas to reduce ammonia slip. Urea mixer components are required to facilitate evaporation and mixing, because it is difficult to evaporate urea in the liquid state; the injection parameters are the most critical factors affecting mixer performance. In this study, The effect of urea injection on NOx emissions in a six-cylinder, four-stroke internal combustion engine fueled with B80 biodiesel has been experimentally investigated. The results reveal that urea injection leads to a reduction of NOx emissions of B80 biodiesel fuel. Moreover, the influence of injection parameters on NOx reductions has been studied. The findings show that by increasing the injection temperature, more reduction in NOx emissions has been occurred. Also, urea mass flow rate increment leads to more NOx reduction. The same result has been obtained by an increase in spray angle.

Keywords: urea, NOx emissions, diesel engines, biodiesels

Procedia PDF Downloads 495
858 Surface Pressure Distribution of a Flapped-Airfoil for Different Momentum Injection at the Leading Edge

Authors: Mohammad Mashud, S. M. Nahid Hasan

Abstract:

The aim of the research work is to modify the NACA 4215 airfoil with flap and rotary cylinder at the leading edge of the airfoil and experimentally study the static pressure distribution over the airfoil completed with flap and leading-edge vortex generator. In this research, NACA 4215 wing model has been constructed by generating the profile geometry using the standard equations and design software such as AutoCAD and SolidWorks. To perform the experiment, three wooden models are prepared and tested in subsonic wind tunnel. The experiments were carried out in various angles of attack. Flap angle and momentum injection rate are changed to observe the characteristics of pressure distribution. In this research, a new concept of flow separation control mechanism has been introduced to improve the aerodynamic characteristics of airfoil. Control of flow separation over airfoil which experiences a vortex generator (rotating cylinder) at the leading edge of airfoil is experimentally simulated under the effects of momentum injection. The experimental results show that the flow separation control is possible by the proposed mechanism, and benefits can be achieved by momentum injection technique. The wing performance is significantly improved due to control of flow separation by momentum injection method.

Keywords: airfoil, momentum injection, flap, pressure distribution

Procedia PDF Downloads 140
857 Hydrogen Peroxide: A Future for Well Stimulation and Heavy Oil Recovery

Authors: Meet Bhatia

Abstract:

Well stimulation and heavy oil recovery continue to be a hot topic in our industry, particularly with formation damage and viscous oil respectively. Cyclic steam injection has been recognised for most of the operations related to heavy oil recovery. However, the cost of implementation is high and operation is time-consuming, moreover most of the viscous oil reservoirs such as oil sands, Bitumen deposits and oil shales require additional treatment of well stimulation. The use of hydrogen peroxide can efficiently replace the cyclic steam injection process as it can be used for both well stimulation and heavy oil recovery simultaneously. The decomposition of Hydrogen peroxide produces oxygen, superheated steam and heat. The increase in temperature causes clays to shrink, destroy carbonates and remove emulsion thus it can efficiently remove the near wellbore damage. The paper includes mechanisms, parameters to be considered and the challenges during the treatment for the effective hydrogen peroxide injection for both conventional and heavy oil reservoirs.

Keywords: hydrogen peroxide, well stimulation, heavy oil recovery, steam injection

Procedia PDF Downloads 337
856 Factors Affecting the Fear of Insulin Injection and Finger Punching in Individuals Diagnosed with Diabetes

Authors: Gaye Demi̇rtaş Adli

Abstract:

Research: It was conducted to determine the factors affecting the fear of self-injection and self-pricking of fingers of diabetic individuals.The study was conducted as a cross-sectional, relation-seeking, and descriptive study. The study was conducted on 122 patients who had just started insulin therapy. Data were obtained through The Descriptive Patient Form, The Diabetic Self-Injection, and the Fear of Testing Questionnaire Form (D-FISQ). Descriptive statistical methods used in the evaluation of data are the Mann-Whitney U test, Kruskal-Wallis H test, and the Spearman correlation. The factors affecting the scale scores were evaluated with multiple linear regression analysis. The value of P<0.05 was considered statistically significant. Study group: 56.6% of the patients are male patients. Fear of self-injection (injection), fear of self-testing (test), and total fear (total) scores of women were found to be statistically higher than men (p<0.001). Age, gender, and pain experience were important variables that affected patients' fear of injections. With a one-unit increase in age, the injection fear score decreased by 0.13 points, and the mean injection fear score of women was 2.11 points higher than that of men. It was determined that the patient's age, gender, living with whom, and blood donation history were important variables affecting the fear of self-testing. It is seen that the fear test score decreases by 0.18 points with an increase in age by one unit, and the fear test scores of women compared to men are on average 3,358 points, the fear test scores of those living alone are 4,711 points compared to those living with family members, and the fear test scores of those who do not donate blood are 2,572 compared to those who donate blood score, it was determined that those with more pain experience were 3,156 points higher on average than those with less fear of injection. As a result, it was seen that the most important factors affecting the fear of insulin injection and finger punching in individuals with diabetes were age, gender, pain experience, living with whom, and blood donation history.

Keywords: diabetes, needle phobia, fear of injection, insulin injection

Procedia PDF Downloads 72
855 Thermal and Mechanical Properties of Powder Injection Molded Alumina Nano-Powder

Authors: Mostafa Rezaee Saraji, Ali Keshavarz Panahi

Abstract:

In this work, the processing steps for producing alumina parts using powder injection molding (PIM) technique and nano-powder were investigated and the thermal conductivity and flexural strength of samples were determined as a function of sintering temperature and holding time. In the first step, the feedstock with 58 vol. % of alumina nano-powder with average particle size of 100nm was prepared using Extrumixing method to obtain appropriate homogeneity. This feedstock was injection molded into the two cavity mold with rectangular shape. After injection molding step, thermal and solvent debinding methods were used for debinding of molded samples and then these debinded samples were sintered in different sintering temperatures and holding times. From the results, it was found that the flexural strength and thermal conductivity of samples increased by increasing sintering temperature and holding time; in sintering temperature of 1600ºC and holding time of 5h, the flexural strength and thermal conductivity of sintered samples reached to maximum values of 488MPa and 40.8 W/mK, respectively.

Keywords: alumina nano-powder, thermal conductivity, flexural strength, powder injection molding

Procedia PDF Downloads 330
854 Effect of Injection Moulding Process Parameter on Tensile Strength of Using Taguchi Method

Authors: Gurjeet Singh, M. K. Pradhan, Ajay Verma

Abstract:

The plastic industry plays very important role in the economy of any country. It is generally among the leading share of the economy of the country. Since metals and their alloys are very rarely available on the earth. So to produce plastic products and components, which finds application in many industrial as well as household consumer products is beneficial. Since 50% plastic products are manufactured by injection moulding process. For production of better quality product, we have to control quality characteristics and performance of the product. The process parameters plays a significant role in production of plastic, hence the control of process parameter is essential. In this paper the effect of the parameters selection on injection moulding process has been described. It is to define suitable parameters in producing plastic product. Selecting the process parameter by trial and error is neither desirable nor acceptable, as it is often tends to increase the cost and time. Hence optimization of processing parameter of injection moulding process is essential. The experiments were designed with Taguchi’s orthogonal array to achieve the result with least number of experiments. Here Plastic material polypropylene is studied. Tensile strength test of material is done on universal testing machine, which is produced by injection moulding machine. By using Taguchi technique with the help of MiniTab-14 software the best value of injection pressure, melt temperature, packing pressure and packing time is obtained. We found that process parameter packing pressure contribute more in production of good tensile plastic product.

Keywords: injection moulding, tensile strength, poly-propylene, Taguchi

Procedia PDF Downloads 288
853 The Study of Tire Pyrolysis Fuel in CI Diesel Engine for Spray Combustion Character and Performance

Authors: Chun Pao Kuo, Chi Tong Lin

Abstract:

The study explored atomization characteristics of tire pyrolysis fuel and its impacts on using three types of fuel: diesel oil mixed with 10% of tire pyrolysis fuel (called T10), diesel oil mixed with 20% tire pyrolysis (called T20), and consumer-grade diesel oil (D100). The investigators used the fuel for simulation and tests at various fuel injection timing, engine speed, and fuel injection speed to inspect impacts from fuel type on oil droplet atomization speed and output power. Actual vehicle tests were conducted using a 5-ton sedan (Hino) with 3660 cc displacement and a front-end inline four-cylinder diesel engine, and this type of vehicle is easily available from the market. A dynamometer was used to set up three engine speeds for the dynamometer testing at different injection timing and pressure. Next, an exhaust analyzer was used to measure exhaust pollution at different conditions to explore the effect of fuel types and injection speeds on output power in order to establish the best operation conditions for tire pyrolysis fuel.

Keywords: diesel engine, exhaust pollution, fuel injection timing, tire pyrolysis oil

Procedia PDF Downloads 408
852 Optimization of Two Quality Characteristics in Injection Molding Processes via Taguchi Methodology

Authors: Joseph C. Chen, Venkata Karthik Jakka

Abstract:

The main objective of this research is to optimize tensile strength and dimensional accuracy in injection molding processes using Taguchi Parameter Design. An L16 orthogonal array (OA) is used in Taguchi experimental design with five control factors at four levels each and with non-controllable factor vibration. A total of 32 experiments were designed to obtain the optimal parameter setting for the process. The optimal parameters identified for the shrinkage are shot volume, 1.7 cubic inch (A4); mold term temperature, 130 ºF (B1); hold pressure, 3200 Psi (C4); injection speed, 0.61 inch3/sec (D2); and hold time of 14 seconds (E2). The optimal parameters identified for the tensile strength are shot volume, 1.7 cubic inch (A4); mold temperature, 160 ºF (B4); hold pressure, 3100 Psi (C3); injection speed, 0.69 inch3/sec (D4); and hold time of 14 seconds (E2). The Taguchi-based optimization framework was systematically and successfully implemented to obtain an adjusted optimal setting in this research. The mean shrinkage of the confirmation runs is 0.0031%, and the tensile strength value was found to be 3148.1 psi. Both outcomes are far better results from the baseline, and defects have been further reduced in injection molding processes.

Keywords: injection molding processes, taguchi parameter design, tensile strength, high-density polyethylene(HDPE)

Procedia PDF Downloads 197
851 Analysis of Injection-Lock in Oscillators versus Phase Variation of Injected Signal

Authors: M. Yousefi, N. Nasirzadeh

Abstract:

In this paper, behavior of an oscillator under injection of another signal has been investigated. Also, variation of output signal amplitude versus injected signal phase variation, the effect of varying the amplitude of injected signal and quality factor of the oscillator has been investigated. The results show that the locking time depends on phase and the best locking time happens at 180-degrees phase. Also, the effect of injected lock has been discussed. Simulations show that the locking time decreases with signal injection to bulk. Locking time has been investigated versus various phase differences. The effect of phase and amplitude changes on locking time of a typical LC oscillator in 180 nm technology has been investigated.

Keywords: analysis, oscillator, injection-lock oscillator, phase modulation

Procedia PDF Downloads 349
850 A Pattern Recognition Neural Network Model for Detection and Classification of SQL Injection Attacks

Authors: Naghmeh Moradpoor Sheykhkanloo

Abstract:

Structured Query Language Injection (SQLI) attack is a code injection technique in which malicious SQL statements are inserted into a given SQL database by simply using a web browser. Losing data, disclosing confidential information or even changing the value of data are the severe damages that SQLI attack can cause on a given database. SQLI attack has also been rated as the number-one attack among top ten web application threats on Open Web Application Security Project (OWASP). OWASP is an open community dedicated to enabling organisations to consider, develop, obtain, function, and preserve applications that can be trusted. In this paper, we propose an effective pattern recognition neural network model for detection and classification of SQLI attacks. The proposed model is built from three main elements of: a Uniform Resource Locator (URL) generator in order to generate thousands of malicious and benign URLs, a URL classifier in order to: 1) classify each generated URL to either a benign URL or a malicious URL and 2) classify the malicious URLs into different SQLI attack categories, and an NN model in order to: 1) detect either a given URL is a malicious URL or a benign URL and 2) identify the type of SQLI attack for each malicious URL. The model is first trained and then evaluated by employing thousands of benign and malicious URLs. The results of the experiments are presented in order to demonstrate the effectiveness of the proposed approach.

Keywords: neural networks, pattern recognition, SQL injection attacks, SQL injection attack classification, SQL injection attack detection

Procedia PDF Downloads 470
849 Injection Effect of Botulinum Toxin A on Hallux Valgus Deformity and Pain

Authors: Alireza Moghtaderi, Negin Khakpour

Abstract:

Hallux Valgus is a kind of Toes aberration where the Metatarsophalangeal joint that connects the big toe to the foot, leading to the inner side and a protrusion on the inner surface of toe arise. This study aimed to determine the effect of botulinum toxin A injection to reduce pain and deviation angle of the thumb in Hallux Valgus and to increase outcomes of treatment as an adjuvant therapy. Randomized clinical study was performed on 18 patients at the Clinic of Physical Medicine and Rehabilitation, Isfahan University of Medical Sciences. In this study the Halgvs valgus angle (HVA) between the metatarsals (IMA) and cartilage distal metatarsal angle (DMAA) and pain were assessed before and after injection. Average of Hallux Valgus angle before and after Botox injections were 28/89 ± 10/21 and 21/56 ± 8/22 degrees and the angle deviation in the 6 months after treatment was significantly improved (p <0.001). Injection of botulinum toxin A is a suitable and acceptable method to reform the skeleton deformities and also to reduce the pain in patients with Hallux valgus.

Keywords: metatasal, hallux valgus, pain, botulinum toxuin

Procedia PDF Downloads 130