2849 A Gauge Repeatability and Reproducibility Study for Multivariate Measurement Systems

Authors: Jeh-Nan Pan, Chung-I Li

Abstract:

Measurement system analysis (MSA) plays an important role in helping organizations to improve their product quality. Generally speaking, the gauge repeatability and reproducibility (GRR) study is performed according to the MSA handbook stated in QS9000 standards. Usually, GRR study for assessing the adequacy of gauge variation needs to be conducted prior to the process capability analysis. Traditional MSA only considers a single quality characteristic. With the advent of modern technology, industrial products have become very sophisticated with more than one quality characteristic. Thus, it becomes necessary to perform multivariate GRR analysis for a measurement system when collecting data with multiple responses. In this paper, we take the correlation coefficients among tolerances into account to revise the multivariate precision-to-tolerance (P/T) ratio as proposed by Majeske (2008). We then compare the performance of our revised P/T ratio with that of the existing ratios. The simulation results show that our revised P/T ratio outperforms others in terms of robustness and proximity to the actual value. Moreover, the optimal allocation of several parameters such as the number of quality characteristics (v), sample size of parts (p), number of operators (o) and replicate measurements (r) is discussed using the confidence interval of the revised P/T ratio. Finally, a standard operating procedure (S.O.P.) to perform the GRR study for multivariate measurement systems is proposed based on the research results. Hopefully, it can be served as a useful reference for quality practitioners when conducting such study in industries. Measurement system analysis (MSA) plays an important role in helping organizations to improve their product quality. Generally speaking, the gauge repeatability and reproducibility (GRR) study is performed according to the MSA handbook stated in QS9000 standards. Usually, GRR study for assessing the adequacy of gauge variation needs to be conducted prior to the process capability analysis. Traditional MSA only considers a single quality characteristic. With the advent of modern technology, industrial products have become very sophisticated with more than one quality characteristic. Thus, it becomes necessary to perform multivariate GRR analysis for a measurement system when collecting data with multiple responses. In this paper, we take the correlation coefficients among tolerances into account to revise the multivariate precision-to-tolerance (P/T) ratio as proposed by Majeske (2008). We then compare the performance of our revised P/T ratio with that of the existing ratios. The simulation results show that our revised P/T ratio outperforms others in terms of robustness and proximity to the actual value. Moreover, the optimal allocation of several parameters such as the number of quality characteristics (v), sample size of parts (p), number of operators (o) and replicate measurements (r) is discussed using the confidence interval of the revised P/T ratio. Finally, a standard operating procedure (S.O.P.) to perform the GRR study for multivariate measurement systems is proposed based on the research results. Hopefully, it can be served as a useful reference for quality practitioners when conducting such study in industries.

Keywords: gauge repeatability and reproducibility, multivariate measurement system analysis, precision-to-tolerance ratio, Gauge repeatability

Procedia PDF Downloads 233
2848 Smart Irrigation System

Authors: Levent Seyfi, Ertan Akman, Tuğrul C. Topak

Abstract:

In this study, irrigation automation with electronic sensors and its control with smartphones were aimed. In this context, temperature and soil humidity measurements of the area irrigated were obtained by temperature and humidity sensors. A micro controller (Arduino) was utilized for accessing values of these parameters and controlling the proposed irrigation system. The irrigation system could automatically be worked according to obtained measurement values. Besides, a GSM module used together with Arduino provided that the irrigation system was in connection to smartphones. Thus, the irrigation system can be remotely controlled. Not only can we observe whether the irrigation system is working or not via developed special android application but also we can see temperature and humidity measurement values. In addition to this, if desired, the irrigation system can be remotely and manually started or stopped regardless of measured sensor vales thanks to the developed android application. In addition to smartphones, the irrigation system can be alternatively controlled via the designed website (www.sulamadenetim.com).

Keywords: smartphone, Android Operating System, sensors, irrigation System, arduino

Procedia PDF Downloads 592
2847 The Combined Effect of Different Levels of Fe(III) in Diet and Cr(III) Supplementation on the Ca Status in Wistar

Authors: Staniek Halina

Abstract:

The inappropriate trace elements supply such as iron(III) and chromium(III) may be risk factors of many metabolic disorders (e.g., anemia, diabetes, as well cause toxic effect). However, little is known about their mutual interactions and their impact on these disturbances. The effects of Cr(III) supplementation with a deficit or excess supply of Fe(III) in vivo conditions are not known yet. The objective of the study was to investigate the combined effect of different Fe(III) levels in the diet and simultaneous Cr(III) supplementation on the Ca distribution in organs in healthy rats. The assessment was based on a two-factor (2x3) experiment carried out on 54 female Wistar rats (Rattus norvegicus). The animals were randomly divided into 9 groups and for 6 weeks, they were fed semi-purified diets AIN-93 with three different Fe(III) levels in the diet as a factor A [control (C) 45 mg/kg (100% Recommended Daily Allowance for rodents), deficient (D) 5 mg/kg (10% RDA), and oversupply (H) 180 mg/kg (400% RDA)]. The second factor (B) was the simultaneous dietary supplementation with Cr(III) at doses of 1, 50 and 500 mg/kg of the diet. Iron(III) citrate was the source of Fe(III). The complex of Cr(III) with propionic acid, also called Cr₃ or chromium(III) propionate (CrProp), was used as a source of Cr(III) in the diet. The Ca content of analysed samples (liver, kidneys, spleen, heart, and femur) was determined with the Atomic Absorption Spectrometry (AAS) method. It was found that different dietary Fe(III) supply as well as Cr(III) supplementation independently and in combination influenced Ca metabolism in healthy rats. Regardless of the supplementation of Cr(III), the oversupply of Fe(III) (180 mg/kg) decreased the Ca content in the liver and kidneys, while it increased the Ca saturation of bone tissue. High Cr(III) doses lowered the hepatic Ca content. Moreover, it tended to decrease the Ca content in the kidneys and heart, but this effect was not statistically significant. The combined effect of the experimental factors on the Ca content in the liver and the femur was observed. With the increase in the Fe(III) content in the diet, there was a decrease in the Ca level in the liver and an increase in bone saturation, and the additional Cr(III) supplementation intensified those effects. The study proved that the different Fe(III) content in the diet, independently and in combination with Cr(III) supplementation, affected the Ca distribution in organisms of healthy rats.

Keywords: calcium, chromium(III), iron(III), rats, supplementation

Procedia PDF Downloads 171
2846 Experimental Chip/Tool Temperature FEM Model Calibration by Infrared Thermography: A Case Study

Authors: Riccardo Angiuli, Michele Giannuzzi, Rodolfo Franchi, Gabriele Papadia

Abstract:

Temperature knowledge in machining is fundamental to improve the numerical and FEM models used for the study of some critical process aspects, such as the behavior of the worked material and tool. The extreme conditions in which they operate make it impossible to use traditional measuring instruments; infrared thermography can be used as a valid measuring instrument for temperature measurement during metal cutting. In the study, a large experimental program on superduplex steel (ASTM A995 gr. 5A) cutting was carried out, the relevant cutting temperatures were measured by infrared thermography when certain cutting parameters changed, from traditional values to extreme ones. The values identified were used to calibrate a FEM model for the prediction of residual life of the tools. During the study, the problems related to the detection of cutting temperatures by infrared thermography were analyzed, and a dedicated procedure was developed that could be used during similar processing.

Keywords: machining, infrared thermography, FEM, temperature measurement

Procedia PDF Downloads 163
2845 Cepstrum Analysis of Human Walking Signal

Authors: Koichi Kurita

Abstract:

In this study, we propose a real-time data collection technique for the detection of human walking motion from the charge generated on the human body. This technique is based on the detection of a sub-picoampere electrostatic induction current, generated by the motion, flowing through the electrode of a wireless portable sensor attached to the subject. An FFT analysis of the wave-forms of the electrostatic induction currents generated by the walking motions showed that the currents generated under normal and restricted walking conditions were different. Moreover, we carried out a cepstrum analysis to detect any differences in the walking style. Results suggest that a slight difference in motion, either due to the individual’s gait or a splinted leg, is directly reflected in the electrostatic induction current generated by the walking motion. The proposed wireless portable sensor enables the detection of even subtle differences in walking motion.

Keywords: human walking motion, motion measurement, current measurement, electrostatic induction

Procedia PDF Downloads 319
2844 Calcium Silicate Bricks – Ultrasonic Pulse Method: Effects of Natural Frequency of Transducers on Measurement Results

Authors: Jiri Brozovsky

Abstract:

Modulus of elasticity is one of the important parameters of construction materials, which considerably influence their deformation properties and which can also be determined by means of non-destructive test methods like ultrasonic pulse method. However, measurement results of ultrasonic pulse methods are influenced by various factors, one of which is the natural frequency of the transducers. The paper states knowledge about influence of natural frequency of the transducers (54; 82 and 150kHz) on ultrasonic pulse velocity and dynamic modulus of elasticity (Young's Dynamic modulus of elasticity). Differences between ultrasonic pulse velocity and dynamic modulus of elasticity were found with the same smallest dimension of test specimen in the direction of sounding and density their value decreases as the natural frequency of transducers grew.

Keywords: calcium silicate brick, ultrasonic pulse method, ultrasonic pulse velocity, dynamic modulus of elasticity

Procedia PDF Downloads 393
2843 Corrosion Inhibition of Copper in 1M HNO3 Solution by Oleic Acid

Authors: S. Nigri, R. Oumeddour, F. Djazi

Abstract:

The inhibition of the corrosion of copper in 1 M HNO3 solution by oleic acid was investigated by weight loss measurement, potentiodynamic polarization and scanning electron microscope (SEM) studies. The experimental results have showed that this compound revealed a good corrosion inhibition and the inhibition efficiency is increased with the inhibitor concentration to reach 98%. The results obtained revealed that the adsorption of the inhibitor molecule onto metal surface is found to obey Langmuir adsorption isotherm. The temperature effect on the corrosion behavior of copper in 1 M HNO3 without and with inhibitor at different concentration was studied in the temperature range from 303 to 333 K and the kinetic parameters activation such as Ea, ∆Ha and ∆Sa were evaluated. Tafel plot analysis revealed that oleic acid acts as a mixed type inhibitor. SEM analysis substantiated the formation of protective layer over the copper surface.

Keywords: oleic acid, weight loss, electrochemical measurement, SEM analysis

Procedia PDF Downloads 370
2842 Modular Robotics and Terrain Detection Using Inertial Measurement Unit Sensor

Authors: Shubhakar Gupta, Dhruv Prakash, Apoorv Mehta

Abstract:

In this project, we design a modular robot capable of using and switching between multiple methods of propulsion and classifying terrain, based on an Inertial Measurement Unit (IMU) input. We wanted to make a robot that is not only intelligent in its functioning but also versatile in its physical design. The advantage of a modular robot is that it can be designed to hold several movement-apparatuses, such as wheels, legs for a hexapod or a quadpod setup, propellers for underwater locomotion, and any other solution that may be needed. The robot takes roughness input from a gyroscope and an accelerometer in the IMU, and based on the terrain classification from an artificial neural network; it decides which method of propulsion would best optimize its movement. This provides the bot with adaptability over a set of terrains, which means it can optimize its locomotion on a terrain based on its roughness. A feature like this would be a great asset to have in autonomous exploration or research drones.

Keywords: modular robotics, terrain detection, terrain classification, neural network

Procedia PDF Downloads 118
2841 Location Detection of Vehicular Accident Using Global Navigation Satellite Systems/Inertial Measurement Units Navigator

Authors: Neda Navidi, Rene Jr. Landry

Abstract:

Vehicle tracking and accident recognizing are considered by many industries like insurance and vehicle rental companies. The main goal of this paper is to detect the location of a car accident by combining different methods. The methods, which are considered in this paper, are Global Navigation Satellite Systems/Inertial Measurement Units (GNSS/IMU)-based navigation and vehicle accident detection algorithms. They are expressed by a set of raw measurements, which are obtained from a designed integrator black box using GNSS and inertial sensors. Another concern of this paper is the definition of accident detection algorithm based on its jerk to identify the position of that accident. In fact, the results convinced us that, even in GNSS blockage areas, the position of the accident could be detected by GNSS/INS integration with 50% improvement compared to GNSS stand alone.

Keywords: driver behavior monitoring, integration, IMU, GNSS, monitoring, tracking

Procedia PDF Downloads 198
2840 Framework Development of Carbon Management Software Tool in Sustainable Supply Chain Management of Indian Industry

Authors: Sarbjit Singh

Abstract:

This framework development explored the status of GSCM in manufacturing SMEs and concluded that there was a significant gap w.r.t carbon emissions measurement in the supply chain activities. The measurement of carbon emissions within supply chains is important green initiative toward its reduction. The majority of the SMEs were facing the problem to quantify the green house gas emissions in its supply chain & to make it a low carbon supply chain or GSCM. Thus, the carbon management initiatives were amalgamated with the supply chain activities in order to measure and reduce the carbon emissions, confirming the GHG protocol scopes. Henceforth, it covers the development of carbon management software (CMS) tool to quantify carbon emissions for effective carbon management. This tool is cheap and easy to use for the industries for the management of their carbon emissions within the supply chain.

Keywords: w.r.t carbon emissions, carbon management software, supply chain management, Indian Industry

Procedia PDF Downloads 436
2839 The Methods of Customer Satisfaction Measurement and Its Statistical Analysis towards Sales and Logistic Activities in Food Sector

Authors: Seher Arslankaya, Bahar Uludağ

Abstract:

Meeting the needs and demands of customers and pleasing the customers are important requirements for companies in food sectors where the growth of competition is significantly unpredictable. Customer satisfaction is also one of the key concepts which is mainly driven by wide range of customer preference and expectation upon products and services introduced and delivered to them. In order to meet the customer demands, the companies that engage in food sectors are expected to have a well-managed set of Total Quality Management (TQM), which sets out to improve quality of products and services; to reduce costs and to increase customer satisfaction by restructuring traditional management practices. It aims to increase customer satisfaction by meeting (their) customer expectations and requirements. The achievement would be determined with the help of customer satisfaction surveys, which is done to obtain immediate feedback and to provide quick responses. In addition, the surveys would also assist the making of strategic planning which helps to anticipate customer future needs and expectations. Meanwhile, periodic measurement of customer satisfaction would be a must because with the better understanding of customers perceptions from the surveys (done by questioners), the companies would have a clear idea to identify their own strengths and weaknesses that help the companies keep their loyal customers; to stand in comparison toward their competitors and map out their future progress and improvement. In this study, we propose a survey based on customer satisfaction measurement method and its statistical analysis for sales and logistic activities of food firms. Customer satisfaction would be discussed in details. Furthermore, after analysing the data derived from the questionnaire that applied to customers by using the SPSS software, various results obtained from the application would be presented. By also applying ANOVA test, the study would analysis the existence of meaningful differences between customer demographic proportion and their perceptions. The purpose of this study is also to find out requirements which help to remove the effects that decrease customer satisfaction and produce loyal customers in food industry. For this purpose, the customer complaints are collected. Additionally, comments and suggestions are done according to the obtained results of surveys, which would be useful for the making-process of strategic planning in food industry.

Keywords: customer satisfaction measurement and analysis, food industry, SPSS, TQM

Procedia PDF Downloads 228
2838 Prediction of Bubbly Plume Characteristics Using the Self-Similarity Model

Authors: Li Chen, Alex Skvortsov, Chris Norwood

Abstract:

Gas releasing into water can be found in for many industrial situations. This process results in the formation of bubbles and acoustic emission which depends upon the bubble characteristics. If the bubble creation rates (bubble volume flow rate) are of interest, an inverse method has to be used based on the measurement of acoustic emission. However, there will be sound attenuation through the bubbly plume which will influence the measurement and should be taken into consideration in the model. The sound transmission through the bubbly plume depends on the characteristics of the bubbly plume, such as the shape and the bubble distributions. In this study, the bubbly plume shape is modelled using a self-similarity model, which has been normally applied for a single phase buoyant plume. The prediction is compared with the experimental data. It has been found the model can be applied to a buoyant plume of gas-liquid mixture. The influence of the gas flow rate and discharge nozzle size is studied.

Keywords: bubbly plume, buoyant plume, bubble acoustics, self-similarity model

Procedia PDF Downloads 263
2837 Mainland China and Taiwan’s Strategies for Overcoming the Middle/High Income Trap: Domestic Consensus-Building and the Foundations of Cross-Strait Interactions

Authors: Mingke Ma

Abstract:

The recent discovery of the High-Income Trap phenomena and the established Middle-Income Trap literature have identified the similarity of the structural challenges that both Mainland China and Taiwan have been facing since the simultaneous growth slowdown from the 2000s. Mainland China and Taiwan’s ineffectiveness in productivity growth weakened their overall competitiveness in Global Value Chains. With the subsequent decline of industrial profitability, social compression from late development persists and jeopardises the social cohesion. From Ma Ying-jeou’s ‘633’ promise and Tsai Ing-wen’s ‘5+2’ industrial framework to Mainland China’s 11th to 14th Five-Year Plans, leaderships across the Strait have been striving to constitute new models for inclusive and sustainable development through policy responses. This study argues that social consensuses that have been constructed by the domestic political processes define the feasibility of the reform strategies, which further construct the conditions for Cross-Strait interactions. Based on the existing literature of New Institutional Economics, Middle/High Income Trap, and Compressed Development, this study adopts a Historical Institutionalist analytical framework to identify how the historical path-dependency contributes to the contemporary growth constraints in both economies and the political difficulty on navigating the institutional and Organisational change. It continues by tracing the political process of economic reform to examine the sustainability and resilience of the manifested social consensus that had empowered the proposed policy frameworks. Afterwards, it examines how the political outcomes in such a simultaneous process shared by both Mainland China and Taiwan construct the social, economic, institutional, and political foundations of contemporary Cross-Strait engagement.

Keywords: historical institutionalism, political economy, cross-strait relations, high/middle income trap

Procedia PDF Downloads 172
2836 Surfactant Improved Heavy Oil Recovery in Sandstone Reservoirs by Wettability Alteration

Authors: Rabia Hunky, Hayat Kalifa, Bai

Abstract:

The wettability of carbonate reservoirs has been widely recognized as an important parameter in oil recovery by flooding technology. Many surfactants have been studied for this application. However, the importance of wettability alteration in sandstone reservoirs by surfactant has been poorly studied. In this paper, our recent study of the relationship between rock surface wettability and cumulative oil recovery for sandstone cores is reported. In our research, it has been found there is a good agreement between the wettability and oil recovery. Nonionic surfactants, Tomadol® 25-12 and Tomadol® 45-13, are very effective in wettability alteration of sandstone core surface from highly oil-wet conditions to water-wet conditions. By spontaneous imbibition test, Interfacial tension, and contact angle measurement these two surfactants exhibit the highest recovery of the synthetic oil made with heavy oil. Based on these experimental results, we can further conclude that the contact angle measurement and imbibition test can be used as rapid screening tools to identify better EOR surfactants to increase heavy oil recovery from sandstone reservoirs.

Keywords: EOR, oil gas, IOR, WC, IF, oil and gas

Procedia PDF Downloads 75
2835 Effects of Different Kinds of Combined Action Observation and Motor Imagery on Improving Golf Putting Performance and Learning

Authors: Chi H. Lin, Chi C. Lin, Chih L. Hsieh

Abstract:

Motor Imagery (MI) alone or combined with action observation (AO) has been shown to enhance motor performance and skill learning. The most effective way to combine these techniques has received limited scientific scrutiny. In the present study, we examined the effects of simultaneous (i.e., observing an action whilst imagining carrying out the action concurrently), alternate (i.e., observing an action and then doing imagery related to that action consecutively) and synthesis (alternately perform action observation and imagery action and then perform observation and imagery action simultaneously) AOMI combinations on improving golf putting performance and learning. Participants, 45 university students who had no formal experience of using imagery for the study, were randomly allocated to one of four training groups: simultaneous action observation and motor imagery (S-AOMI), alternate action observation and motor imagery (A-AOMI), synthesis action observation and motor imagery (A-S-AOMI), and a control group. And it was applied 'Different Experimental Groups with Pre and Post Measured' designs. Participants underwent eighteen times of different interventions, which were happened three times a week and lasting for six weeks. We analyzed the information we received based on two-factor (group × times) mixed between and within analysis of variance to discuss the real effects on participants' golf putting performance and learning about different intervention methods of different types of combined action observation and motor imagery. After the intervention, we then used imagery questionnaire and journey to understand the condition and suggestion about different motor imagery and action observation intervention from the participants. The results revealed that the three experimental groups both are effective in putting performance and learning but not for the control group, and the A-S-AOMI group is significantly better effect than S-AOMI group on golf putting performance and learning. The results confirmed the effect of motor imagery combined with action observation on the performance and learning of golf putting. In particular, in the groups of synthesis, motor imagery, or action observation were alternately performed first and then performed motor imagery, and action observation simultaneously would have the best effectiveness.

Keywords: motor skill learning, motor imagery, action observation, simulation

Procedia PDF Downloads 112
2834 Improvement of Camera Calibration Based on the Relationship between Focal Length and Aberration Coefficient

Authors: Guorong Sui, Xingwei Jia, Chenhui Yin, Xiumin Gao

Abstract:

In the processing of camera-based high precision and non-contact measurement, the geometric-optical aberration is always inevitably disturbing the measuring system. Moreover, the aberration is different with the different focal length, which will increase the difficulties of the system’s calibration. Therefore, to understand the relationship between the focal length as a function of aberration properties is a very important issue to the calibration of the measuring systems. In this study, we propose a new mathematics model, which is based on the plane calibration method by Zhang Zhengyou, and establish a relationship between the focal length and aberration coefficient. By using the mathematics model and carefully modified compensation templates, the calibration precision of the system can be dramatically improved. The experiment results show that the relative error is less than 1%. It is important for optoelectronic imaging systems that apply to measure, track and position by changing the camera’s focal length.

Keywords: camera calibration, aberration coefficient, vision measurement, focal length, mathematics model

Procedia PDF Downloads 335
2833 Modeling of Particle Reduction and Volatile Compounds Profile during Chocolate Conching by Electronic Nose and Genetic Programming (GP) Based System

Authors: Juzhong Tan, William Kerr

Abstract:

Conching is one critical procedure in chocolate processing, where special flavors are developed, and smooth mouse feel the texture of the chocolate is developed due to particle size reduction of cocoa mass and other additives. Therefore, determination of the particle size and volatile compounds profile of cocoa bean is important for chocolate manufacturers to ensure the quality of chocolate products. Currently, precise particle size measurement is usually done by laser scattering which is expensive and inaccessible to small/medium size chocolate manufacturers. Also, some other alternatives, such as micrometer and microscopy, can’t provide good measurements and provide little information. Volatile compounds analysis of cocoa during conching, has similar problems due to its high cost and limited accessibility. In this study, a self-made electronic nose system consists of gas sensors (TGS 800 and 2000 series) was inserted to a conching machine and was used to monitoring the volatile compound profile of chocolate during the conching. A model correlated volatile compounds profiles along with factors including the content of cocoa, sugar, and the temperature during the conching to particle size of chocolate particles by genetic programming was established. The model was used to predict the particle size reduction of chocolates with different cocoa mass to sugar ratio (1:2, 1:1, 1.5:1, 2:1) at 8 conching time (15min, 30min, 1h, 1.5h, 2h, 4h, 8h, and 24h). And the predictions were compared to laser scattering measurements of the same chocolate samples. 91.3% of the predictions were within the range of later scatting measurement ± 5% deviation. 99.3% were within the range of later scatting measurement ± 10% deviation.

Keywords: cocoa bean, conching, electronic nose, genetic programming

Procedia PDF Downloads 228
2832 Use of In-line Data Analytics and Empirical Model for Early Fault Detection

Authors: Hyun-Woo Cho

Abstract:

Automatic process monitoring schemes are designed to give early warnings for unusual process events or abnormalities as soon as possible. For this end, various techniques have been developed and utilized in various industrial processes. It includes multivariate statistical methods, representation skills in reduced spaces, kernel-based nonlinear techniques, etc. This work presents a nonlinear empirical monitoring scheme for batch type production processes with incomplete process measurement data. While normal operation data are easy to get, unusual fault data occurs infrequently and thus are difficult to collect. In this work, noise filtering steps are added in order to enhance monitoring performance by eliminating irrelevant information of the data. The performance of the monitoring scheme was demonstrated using batch process data. The results showed that the monitoring performance was improved significantly in terms of detection success rate of process fault.

Keywords: batch process, monitoring, measurement, kernel method

Procedia PDF Downloads 301
2831 An Application of Extreme Value Theory as a Risk Measurement Approach in Frontier Markets

Authors: Dany Ng Cheong Vee, Preethee Nunkoo Gonpot, Noor Sookia

Abstract:

In this paper, we consider the application of Extreme Value Theory as a risk measurement tool. The Value at Risk, for a set of indices, from six Stock Exchanges of Frontier markets is calculated using the Peaks over Threshold method and the performance of the model index-wise is evaluated using coverage tests and loss functions. Our results show that 'fat-tailedness' alone of the data is not enough to justify the use of EVT as a VaR approach. The structure of the returns dynamics is also a determining factor. This approach works fine in markets which have had extremes occurring in the past thus making the model capable of coping with extremes coming up (Colombo, Tunisia and Zagreb Stock Exchanges). On the other hand, we find that indices with lower past than present volatility fail to adequately deal with future extremes (Mauritius and Kazakhstan). We also conclude that using EVT alone produces quite static VaR figures not reflecting the actual dynamics of the data.

Keywords: extreme value theory, financial crisis 2008, value at risk, frontier markets

Procedia PDF Downloads 259
2830 An Experimental Study on the Measurement of Fuel to Air Ratio Using Flame Chemiluminescence

Authors: Sewon Kim, Chang Yeop Lee, Minjun Kwon

Abstract:

This study is aiming at establishing the relationship between the optical signal of flame and an equivalent ratio of flame. In this experiment, flame optical signal in a furnace is measured using photodiode. The combustion system which is composed of metal fiber burner and vertical furnace and flame chemiluminescence is measured at various experimental conditions. In this study, the flame chemiluminescence of laminar premixed flame is measured by using commercially available photodiode. It is experimentally investigated the relationship between equivalent ratio and photodiode signal. In addition, The strategy of combustion control method is proposed by using the optical signal and fuel pressure. The results showed that certain relationship between optical data of photodiode and equivalence ratio exists and this leads to the successful application of this system for instantaneous measurement of equivalence ration of the combustion system.

Keywords: flame chemiluminescence, photo diode, equivalence ratio, combustion control

Procedia PDF Downloads 377
2829 One Pot Synthesis of Cu–Ni–S/Ni Foam for the Simultaneous Removal and Detection of Norfloxacin

Authors: Xincheng Jiang, Yanyan An, Yaoyao Huang, Wei Ding, Manli Sun, Hong Li, Huaili Zheng

Abstract:

The residual antibiotics in the environment will pose a threat to the environment and human health. Thus, efficient removal and rapid detection of norfloxacin (NOR) in wastewater is very important. The main sources of NOR pollution are the agricultural, pharmaceutical industry and hospital wastewater. The total consumption of NOR in China can reach 5440 tons per year. It is found that neither animals nor humans can totally absorb and metabolize NOR, resulting in the excretion of NOR into the environment. Therefore, residual NOR has been detected in water bodies. The hazards of NOR in wastewater lie in three aspects: (1) the removal capacity of the wastewater treatment plant for NOR is limited (it is reported that the average removal efficiency of NOR in the wastewater treatment plant is only 68%); (2) NOR entering the environment will lead to the emergence of drug-resistant strains; (3) NOR is toxic to many aquatic species. At present, the removal and detection technologies of NOR are applied separately, which leads to a cumbersome operation process. The development of simultaneous adsorption-flocculation removal and FTIR detection of pollutants has three advantages: (1) Adsorption-flocculation technology promotes the detection technology (the enrichment effect on the material surface improves the detection ability); (2) The integration of adsorption-flocculation technology and detection technology reduces the material cost and makes the operation easier; (3) FTIR detection technology endows the water treatment agent with the ability of molecular recognition and semi-quantitative detection for pollutants. Thus, it is of great significance to develop a smart water treatment material with high removal capacity and detection ability for pollutants. This study explored the feasibility of combining NOR removal method with the semi-quantitative detection method. A magnetic Cu-Ni-S/Ni foam was synthesized by in-situ loading Cu-Ni-S nanostructures on the surface of Ni foam. The novelty of this material is the combination of adsorption-flocculation technology and semi-quantitative detection technology. Batch experiments showed that Cu-Ni-S/Ni foam has a high removal rate of NOR (96.92%), wide pH adaptability (pH=4.0-10.0) and strong ion interference resistance (0.1-100 mmol/L). According to the Langmuir fitting model, the removal capacity can reach 417.4 mg/g at 25 °C, which is much higher than that of other water treatment agents reported in most studies. Characterization analysis indicated that the main removal mechanisms are surface complexation, cation bridging, electrostatic attraction, precipitation and flocculation. Transmission FTIR detection experiments showed that NOR on Cu-Ni-S/Ni foam has easily recognizable FTIR fingerprints; the intensity of characteristic peaks roughly reflects the concentration information to some extent. This semi-quantitative detection method has a wide linear range (5-100 mg/L) and a low limit of detection (4.6 mg/L). These results show that Cu-Ni-S/Ni foam has excellent removal performance and semi-quantitative detection ability of NOR molecules. This paper provides a new idea for designing and preparing multi-functional water treatment materials to achieve simultaneous removal and semi-quantitative detection of organic pollutants in water.

Keywords: adsorption-flocculation, antibiotics detection, Cu-Ni-S/Ni foam, norfloxacin

Procedia PDF Downloads 49
2828 Fracture Crack Monitoring Using Digital Image Correlation Technique

Authors: B. G. Patel, A. K. Desai, S. G. Shah

Abstract:

The main of objective of this paper is to develop new measurement technique without touching the object. DIC is advance measurement technique use to measure displacement of particle with very high accuracy. This powerful innovative technique which is used to correlate two image segments to determine the similarity between them. For this study, nine geometrically similar beam specimens of different sizes with (steel fibers and glass fibers) and without fibers were tested under three-point bending in a closed loop servo-controlled machine with crack mouth opening displacement control with a rate of opening of 0.0005 mm/sec. Digital images were captured before loading (unreformed state) and at different instances of loading and were analyzed using correlation techniques to compute the surface displacements, crack opening and sliding displacements, load-point displacement, crack length and crack tip location. It was seen that the CMOD and vertical load-point displacement computed using DIC analysis matches well with those measured experimentally.

Keywords: Digital Image Correlation, fibres, self compacting concrete, size effect

Procedia PDF Downloads 365
2827 Assessing Perinatal Mental Illness during the COVID-19 Pandemic: A Review of Measurement Tools

Authors: Mya Achike

Abstract:

Background and Significance: Perinatal mental illness covers a wide range of conditions and has a huge influence on maternal-child health. Issues and challenges with perinatal mental health have been associated with poor pregnancy, birth, and postpartum outcomes. It is estimated that one out of five new and expectant mothers experience some degree of perinatal mental illness, which makes this a hugely significant health outcome. Certain factors increase the maternal risk for mental illness. Challenges related to poverty, migration, extreme stress, exposure to violence, emergency and conflict situations, natural disasters, and pandemics can exacerbate mental health disorders. It is widely expected that perinatal mental health is being negatively affected during the present COVID-19 pandemic. Methods: A review of studies that reported a measurement tool to assess perinatal mental health outcomes during the COVID-19 pandemic was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. PubMed, CINAHL, and Google Scholar were used to search for peer-reviewed studies published after late 2019, in accordance with the emergence of the virus. The search resulted in the inclusion of ten studies. Approach to measure health outcome: The main approach to measure perinatal mental illness is the use of self-administered, validated questionnaires, usually in the clinical setting. Summary: Widespread use of these tools has afforded the clinical and research communities the ability to identify and support women who may be suffering from mental illness disorders during a pandemic. More research is needed to validate tools in other vulnerable, perinatal populations.

Keywords: mental health during covid, perinatal mental health, perinatal mental health measurement tools, perinatal mental health tools

Procedia PDF Downloads 107
2826 Investigation of Delivery of Triple Play Data in GE-PON Fiber to the Home Network

Authors: Ashima Anurag Sharma

Abstract:

Optical fiber based networks can deliver performance that can support the increasing demands for high speed connections. One of the new technologies that have emerged in recent years is Passive Optical Networks. This research paper is targeted to show the simultaneous delivery of triple play service (data, voice, and video). The comparison between various data rates is presented. It is demonstrated that as we increase the data rate, number of users to be decreases due to increase in bit error rate.

Keywords: BER, PON, TDMPON, GPON, CWDM, OLT, ONT

Procedia PDF Downloads 502
2825 Dynamic Measurement System Modeling with Machine Learning Algorithms

Authors: Changqiao Wu, Guoqing Ding, Xin Chen

Abstract:

In this paper, ways of modeling dynamic measurement systems are discussed. Specially, for linear system with single-input single-output, it could be modeled with shallow neural network. Then, gradient based optimization algorithms are used for searching the proper coefficients. Besides, method with normal equation and second order gradient descent are proposed to accelerate the modeling process, and ways of better gradient estimation are discussed. It shows that the mathematical essence of the learning objective is maximum likelihood with noises under Gaussian distribution. For conventional gradient descent, the mini-batch learning and gradient with momentum contribute to faster convergence and enhance model ability. Lastly, experimental results proved the effectiveness of second order gradient descent algorithm, and indicated that optimization with normal equation was the most suitable for linear dynamic models.

Keywords: dynamic system modeling, neural network, normal equation, second order gradient descent

Procedia PDF Downloads 102
2824 Spaces of Interpretation: Personal Space

Authors: Yehuda Roth

Abstract:

In quantum theory, a system’s time evolution is predictable unless an observer performs measurement, as the measurement process can randomize the system. This randomness appears when the measuring device does not accurately describe the measured item, i.e., when the states characterizing the measuring device appear as a superposition of those being measured. When such a mismatch occurs, the measured data randomly collapse into a single eigenstate of the measuring device. This scenario resembles the interpretation process in which the observer does not experience an objective reality but interprets it based on preliminary descriptions initially ingrained into his/her mind. This distinction is the motivation for the present study in which the collapse scenario is regarded as part of the interpretation process of the observer. By adopting the formalism of the quantum theory, we present a complete mathematical approach that describes the interpretation process. We demonstrate this process by applying the proposed interpretation formalism to the ambiguous image "My wife and mother-in-law" to identify whether a woman in the picture is young or old.

Keywords: quantum-like interpretation, ambiguous image, determination, quantum-like collapse, classified representation

Procedia PDF Downloads 77
2823 Investigation of Delivery of Triple Play Services

Authors: Paramjit Mahey, Monica Sharma, Jasbinder Singh

Abstract:

Fiber based access networks can deliver performance that can support the increasing demands for high speed connections. One of the new technologies that have emerged in recent years is Passive Optical Networks. This paper is targeted to show the simultaneous delivery of triple play service (data, voice and video). The comparative investigation and suitability of various data rates is presented. It is demonstrated that as we increase the data rate, number of users to be accommodated decreases due to increase in bit error rate.

Keywords: BER, PON, TDMPON, GPON, CWDM, OLT, ONT

Procedia PDF Downloads 519
2822 Defence Ethics : A Performance Measurement Framework for the Defence Ethics Program

Authors: Allyson Dale, Max Hlywa

Abstract:

The Canadian public expects the highest moral standards from Canadian Armed Forces (CAF) members and Department of National Defence (DND) employees. The Chief, Professional Conduct and Culture (CPCC) stood up in April 2021 with the mission of ensuring that the defence culture and members’ conduct are aligned with the ethical principles and values that the organization aspires towards. The Defence Ethics Program (DEP), which stood up in 1997, is a values-based ethics program for individuals and organizations within the DND/CAF and now falls under CPCC. The DEP is divided into five key functional areas, including policy, communications, collaboration, training and education, and advice and guidance. The main focus of the DEP is to foster an ethical culture within defence so that members and organizations perform to the highest ethical standards. The measurement of organizational ethics is often complex and challenging. In order to monitor whether the DEP is achieving its intended outcomes, a performance measurement framework (PMF) was developed using the Director General Military Personnel Research and Analysis (DGMPRA) PMF development process. This evidence-based process is based on subject-matter expertise from the defence team. The goal of this presentation is to describe each stage of the DGMPRA PMF development process and to present and discuss the products of the DEP PMF (e.g., logic model). Specifically, first, a strategic framework was developed to provide a high-level overview of the strategic objectives, mission, and vision of the DEP. Next, Key Performance Questions were created based on the objectives in the strategic framework. A logic model detailing the activities, outputs (what is produced by the program activities), and intended outcomes of the program were developed to demonstrate how the program works. Finally, Key Performance Indicators were developed based on both the intended outcomes in the logic model and the Key Performance Questions in order to monitor program effectiveness. The Key Performance Indicators measure aspects of organizational ethics such as ethical conduct and decision-making, DEP collaborations, and knowledge and awareness of the Defence Ethics Code while leveraging ethics-related items from multiple DGMPRA surveys where appropriate.

Keywords: defence ethics, ethical culture, organizational performance, performance measurement framework

Procedia PDF Downloads 79
2821 Evidence of Scientific-Ness of Scriptures

Authors: Shyam Sunder Gupta

Abstract:

GOD is the infinite source of knowledge and from time to time, as per the need of mankind, keeps revealing a portion of HIS knowledge as” Words” through chosen messengers. In the course of time, ” Words” get converted into scripture. This process of conversion happens after a long gap of time and with the involvement of a large number of persons; and unintentionally scientific and other types of errors get into scriptures; otherwise scriptures are in reality, truly scientific. Description of Chronology of life in the womb (Fetal Development), Five types of rotations of celestial bodies, Speed of the Sun, Rotation of Universe, Multiple verses, Spherical shape of the earth, Measurement of time, Classification of species by nature of birth, Evolution process of non-living matter and living species, etc., most convincing prove that scriptures are truly scientific. In fact, there are many facts for which, till date, science has not found answers, but are available in scriptures; like source of Singularity from which the Big Bang took place and the Universe was created, the Infinite number of Universes, the most fundamental particle, Param-anu( God particle), fundamental of measurement of time and many more.

Keywords: Big Bang, God Particle, Scientific, Scriptures, Singularity, Universe

Procedia PDF Downloads 14
2820 Performance Evaluation of the CareSTART S1 Analyzer for Quantitative Point-Of-Care Measurement of Glucose-6-Phosphate Dehydrogenase Activity

Authors: Haiyoung Jung, Mi Joung Leem, Sun Hwa Lee

Abstract:

Background & Objective: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a genetic abnormality that results in an inadequate amount of G6PD, leading to increased susceptibility of red blood cells to reactive oxygen species and hemolysis. The present study aimed to evaluate the careSTARTTM S1 analyzer for measuring G6PD activity to hemoglobin (Hb) ratio. Methods: Precision for G6PD activity and hemoglobin measurement was evaluated using control materials with two levels on five repeated runs per day for five days. The analytic performance of the careSTARTTM S1 analyzer was compared with spectrophotometry in 40 patient samples. Reference ranges suggested by the manufacturer were validated in 20 healthy males and females each. Results: The careSTARTTM S1 analyzer demonstrated precision of 6.0% for low-level (14~45 U/dL) and 2.7% for high-level (60~90 U/dL) control in G6PD activity, and 1.4% in hemoglobin (7.9~16.3 u/g Hb). A comparison study of G6PD to Hb ratio between the careSTARTTM S1 analyzer and spectrophotometry showed an average difference of 29.1% with a positive bias of the careSTARTTM S1 analyzer. All normal samples from the healthy population were validated for the suggested reference range for males (≥2.19 U/g Hb) and females (≥5.83 U/g Hb). Conclusion: The careSTARTTM S1 analyzer demonstrated good analytical performance and can replace the current spectrophotometric measurement of G6PD enzyme activity. In the aspect of the management of clinical laboratories, it can be a reasonable option as a point-of-care analyzer with minimal handling of samples and reagents, in addition to the automatic calculation of the ratio of measured G6PD activity and Hb concentration, to minimize any clerical errors involved with manual calculation.

Keywords: POCT, G6PD, performance evaluation, careSTART

Procedia PDF Downloads 47