Search results for: tissue engineered aortic heart valve
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2956

Search results for: tissue engineered aortic heart valve

2776 The Application of FSI Techniques in Modeling of Realist Pulmonary Systems

Authors: Abdurrahim Bolukbasi, Hassan Athari, Dogan Ciloglu

Abstract:

The modeling lung respiratory system which has complex anatomy and biophysics presents several challenges including tissue-driven flow patterns and wall motion. Also, the lung pulmonary system because of that they stretch and recoil with each breath, has not static walls and structures. The direct relationship between air flow and tissue motion in the lung structures naturally prefers an FSI simulation technique. Therefore, in order to toward the realistic simulation of pulmonary breathing mechanics the development of a coupled FSI computational model is an important step. A simple but physiologically-relevant three dimensional deep long geometry is designed and fluid-structure interaction (FSI) coupling technique is utilized for simulating the deformation of the lung parenchyma tissue which produces airflow fields. The real understanding of respiratory tissue system as a complex phenomenon have been investigated with respect to respiratory patterns, fluid dynamics and tissue visco-elasticity and tidal breathing period.

Keywords: lung deformation and mechanics; Tissue mechanics; Viscoelasticity; Fluid-structure interactions; ANSYS

Procedia PDF Downloads 290
2775 Heart-Rate Resistance Electrocardiogram Identification Based on Slope-Oriented Neural Networks

Authors: Tsu-Wang Shen, Shan-Chun Chang, Chih-Hsien Wang, Te-Chao Fang

Abstract:

For electrocardiogram (ECG) biometrics system, it is a tedious process to pre-install user’s high-intensity heart rate (HR) templates in ECG biometric systems. Based on only resting enrollment templates, it is a challenge to identify human by using ECG with the high-intensity HR caused from exercises and stress. This research provides a heartbeat segment method with slope-oriented neural networks against the ECG morphology changes due to high intensity HRs. The method has overall system accuracy at 97.73% which includes six levels of HR intensities. A cumulative match characteristic curve is also used to compare with other traditional ECG biometric methods.

Keywords: high-intensity heart rate, heart rate resistant, ECG human identification, decision based artificial neural network

Procedia PDF Downloads 393
2774 Sterilization Effects of Low Concentration of Hydrogen Peroxide Solution on 3D Printed Biodegradable Polyurethane Nanocomposite Scaffold for Heart Valve Regeneration

Authors: S. E. Mohmad-Saberi, W. Song, N. Oliver, M. Adrian, T.C. Hsu, A. Darbyshire

Abstract:

Biodegradable polyurethane (PU) has emerged as a potential material to promote repair and regeneration of damaged/diseased tissues in heart valve regeneration due to its excellent biomechanical profile. Understanding the effects of sterilization on their properties is vital since they are more sensitive and more critical of porous structures compared to bulk ones. In this study, the effects of low concentration of hydrogen peroxide (H₂O₂) solution sterilization has been investigated to determine whether the procedure would be efficient and non-destructive to porous three-dimensional (3D) elastomeric nanocomposite, polyhedral oligomeric silsesquioxane-terminated poly (ethylene-diethylene glycol succinate-sebacate) urea-urethane (POSS-EDSS-PU) scaffold. All the samples were tested for sterility following sterilization using phosphate buffer saline (PBS) as control and 5 % v/v H₂O₂ solution. The samples were incubated in tryptic soy broth for the cultivation of microorganisms under agitation at 37˚C for 72 hours. The effects of the 5 % v/v H₂O₂ solution sterilization were evaluated in terms of morphology, chemical and mechanical properties using scanning electron microscopy (SEM), Fourier transform infrared (FTIR) and tensile tester apparatus. Toxicity effects of the 5 % v/v H₂O₂ solution decontamination were studied by in vitro cytotoxicity test, where the cellular responses of human dermal fibroblast (HDF) were examined. A clear, uncontaminated broth using 5 % v/v H₂O₂ solution method indicated efficient sterilization after 3 days, while the non-sterilized control shows clouding broth indicated contamination. The morphology of 3D POSS-EDSS-PU scaffold appeared to have similar morphology after sterilization with 5 % v/v H₂O₂ solution regarding of pore size and surface. FTIR results show that the sterilized samples and non-sterilized control share the same spectra pattern, confirming no significant alterations over the surface chemistry. For the mechanical properties of the H₂O₂ solution-treated scaffolds, the tensile strain was not significantly decreased, however, become significantly stiffer after the sterilization. No cytotoxic effects were observed after the 5 % v/v H₂O₂ solution sterilization as confirmed by cell viability assessed by Alamar Blue assay. The results suggest that low concentration of 5 % v/v hydrogen peroxide solution can be used as an alternative method for sterilizing biodegradable 3D porous scaffold with micro/nano-architecture without structural deformation. This study provides the understanding of the sterilization effects on biomechanical profile and cell proliferation of 3D POSS-EDSS-PU scaffolds.

Keywords: biodegradable, hydrogen peroxide solution, POSS-EDSS-PU, sterilization

Procedia PDF Downloads 133
2773 An Atlantic Canadian Case of Disseminated Streptococcus equi Subspecies zooepidemicus Infection

Authors: Albert Chang, Duncan Webster

Abstract:

Streptococcus equi subspecies zooepidemicus infections in humans can be contracted through contact with domestic animals or unpasteurized dairy products. Although infection in humans is rare, the course can be fulminant. We describe the case of a 75-year-old, immunocompetent male, who developed disseminated disease with bacteremia, native aortic valve endocarditis, suppurative pericarditis with cardiac tamponade, meningitis and bilateral endopthalmitis. Despite treatment with pericardial drain placement, intravenous ceftriaxone and rifampin the patient, unfortunately, did not survive. To date, reported cases of disseminated infection by S. zooepidemicus are few. Furthermore, with the review of the literature, this case demonstrates the broadest organ system involvement reported. Of interest, previous studies have suggested an affinity of this organism for certain organ systems and this case corroborates an emerging association of S. zooepidemicus with endopthalmitis. In addition, this is the second Canadian case of documented human infection with both cases being similar in clinical features, presentation, and geographical location. A discussion regarding previous S. zooepidemicus outbreaks and the potential for zoonotic outbreaks to occur is included. In short, this case report should serve to warn clinicians regarding complications and sites of haematogenous seeding in the setting of disseminated S. zooepidemicus infections.

Keywords: endopthalmitis, endocarditis, meningitis, Streptococcus equi subspecies zooepidemicus

Procedia PDF Downloads 162
2772 Modern Trends in Pest Management Agroindustry

Authors: Amarjit S Tanda

Abstract:

Integrated Pest Management Technology (IPMT) offers a crop protection model with sustainable agriculture production with minimum damage to the environment and human health. A concept of agro-ecological crop protection seems unsuitable under dynamic environmental systems. To remedy this, we are proposing Genetically Engineered Crop Protection System (GECPS), as an alternate concept in IPMT that suggests how GE cultivars can be optimally put to the service of crop protection. Genetically engineered cultivars which are developed by gene editing biotechnology may provide a preventive defense against the insect pests and plant diseases, a suitable alternative crop system for blending in IPMT program, in the future agro-industry.

Keywords: integrated, pest, management, technology

Procedia PDF Downloads 26
2771 The Incidence of Postoperative Atrial Fibrillation after Coronary Artery Bypass Grafting in Patients with Local and Diffuse Coronary Artery Disease

Authors: Kamil Ganaev, Elina Vlasova, Andrei Shiryaev, Renat Akchurin

Abstract:

De novo atrial fibrillation (AF) after coronary artery bypass grafting (CABG) is a common complication. To date, there are no data on the possible effect of diffuse lesions of coronary arteries on the incidence of postoperative AF complications. Methods. Patients operated on-pump under hypothermic conditions during the calendar year (2020) were studied. Inclusion criteria - isolated CABG and achievement of complete myocardial revascularization. Patients with a history of AF moderate and severe valve dysfunction, hormonal thyroid pathology, initial CHF(Congestive heart failure), as well as patients with developed perioperative complications (IM, acute heart failure, massive blood loss) and deceased were excluded. Thus 227 patients were included; mean age 65±9 years; 69% were men. 89% of patients had a 3-vessel lesion of the coronary artery; the remainder had a 2-vessel lesion. Mean LV size: 3.9±0.3 cm, indexed LV volume: 29.4±5.3 mL/m2. Two groups were considered: D (n=98), patients with diffuse coronary heart disease, and L (n=129), patients with local coronary heart disease. Clinical and demographic characteristics in the groups were comparable. Rhythm assessment: continuous bedside ECG monitoring up to 5 days; ECG CT at 5-7 days after CABG; daily routine ECG registration. Follow-up period - postoperative hospital period. Results. The Median follow-up period was 9 (7;11) days. POFP (Postoperative atrial fibrillation) was detected in 61/227 (27%) patients: 34/98 (35%) in group D versus 27/129 (21%) in group L; p<0.05. Moreover, the values of revascularization index in groups D and L (3.9±0.7 and 3.8±0.5, respectively) were equal, and the mean time Cardiopulmonary bypass (CPB) (107±27 and 80±13min), as well as the mean ischemic time (67±17 and 55±11min) were significantly longer in group D (p<0.05). However, a separate analysis of these parameters in patients with and without developed AF did not reveal any significant differences in group D (CPB time 99±21.2 min, ischemic time 63±12.2 min), or in group L (CPB time 88±13.1 min, ischemic time 58.7±13.2 min). Conclusion. With the diffuse nature of coronary lesions, the incidence of AF in the hospital period after isolated CABG definitely increases. To better understand the role of severe coronary atherosclerosis in the development of POAF, it is necessary to distinguish the influence of organic features of atrial and ventricular myocardium (as a consequence of chronic coronary disease) from the features of surgical correction in diffuse coronary lesions.

Keywords: atrial fibrillation, diffuse coronary artery disease, coronary artery bypass grafting, local coronary artery disease

Procedia PDF Downloads 183
2770 Contribution of mTOR to Oxidative/Nitrosative Stress via NADPH Oxidase System Activation in Zymosan-Induced Systemic Inflammation in Rats

Authors: Seyhan Sahan-Firat, Meryem Temiz-Resitoglu, Demet Sinem Guden, Sefika Pinar Kucukkavruk, Bahar Tunctan, Ayse Nihal Sari, Zumrut Kocak

Abstract:

We hypothesized that mTOR inhibition may prevent the multiple organ failures following severe multiple tissue injury associated with increased NADPH oxidase system activity occur in zymosan-induced systemic inflammation. Therefore, we investigated the role of mTOR in oxidative/nitrosative stress associated with increase in NADPH oxidase activity in zymosan-induced systemic inflammation model in rats. Male Wistar rats received saline (4 ml/kg, i.p.) and zymosan (500 mg/kg, i.p.) at time 0. Saline, or zymosan-treated rats were given rapamycin (1 mg/kg, i.p.) 1 h after saline or zymosan injections. Rats were sacrified 4 h after zymosan challenge and kidney, heart, thoracic aorta, and superior mesenteric artery were collected. NADPH oxidase activity, p22phox, gp91phox, and p47phox protein expression and nitrotyrosine levels were measured in tissue samples. Zymosan administration caused an increase in NADPH oxidase activity, p22phox, gp91phox, and p47phox protein expression and nitrotyrosine levels in kidney, heart, thoracic aorta, and superior mesenteric artery. These changes caused by zymosan reversed by rapamycin, a selective mTOR inhibitor. Rapamycin alone had no effect on the parameters measured. Our results demonstrated that zymosan-induced oxidative/nitrosative stress presumably due to enhanced activity of NADPH oxidase, expression of p22phox, gp91phox, and p47phox and production of peroxynitrite were mediated by mTOR. [This work was financially supported by Research Foundation of Mersin University (2016-2-AP3-1900)].

Keywords: oxidative stress, mTOR, nitrosative stress, zymosan

Procedia PDF Downloads 292
2769 Effects of Stiffness on Endothelial Cells Behavior

Authors: Forough Ataollahi, Sumit Pramanik, Belinda Pingguan-Murphy, Wan Abu Bakar Bin Wan Abas, Noor Azuan Bin Abu Osman

Abstract:

Endothelium proliferation is an important process in cardiovascular homeostasis and can be regulated by extracellular environment, as cells can actively sense mechanical environment. In this study, we evaluated endothelial cell proliferation on PDMS/alumina (Al2O3) composites and pure PDMS. The substrates were prepared from pure PDMS and its composites with 5% and 10% Al2O3 at curing temperature 50˚C for 4 h and then characterized by mechanical, structural and morphological analyses. Higher stiffness was found in the composites compared to the pure PDMS substrate. Cell proliferation of the cultured bovine aortic endothelial cells on substrate materials were evaluated via Resazurin assay and 1, 1’-Dioctadecyl-1, 3, 3, 3’, 3’-Tetramethylindocarbocyanine Perchlorate-Acetylated LDL (Dil-Ac-LDL) cell staining, respectively. The results revealed that stiffer substrates promote more endothelial cells proliferation to the less stiff substrates. Therefore, this study firmly hypothesizes that the stiffness elevates endothelial cells proliferation.

Keywords: stiffness, proliferation, bovine aortic endothelial cells, extra cellular matrix, vascular

Procedia PDF Downloads 317
2768 Enhancing of Laser Imaging by Using Ultrasound Effect

Authors: Hayder Raad Hafuze, Munqith Saleem Dawood, Jamal Abdul Jabbar

Abstract:

The effect of using both ultrasounds with laser in medical imaging of the biological tissue has been studied in this paper. Different wave lengths of incident laser light (405 nm, 532 nm, 650 nm, 808 nm and 1064 nm) were used with different ultrasound frequencies (1MHz and 3.3MHz). The results showed that, the change of acoustic intensity enhance the laser penetration of the tissue for different thickness. The existence of the ideal Raman-Nath diffraction pattern were investigated in terms of phase delay and incident angle.

Keywords: tissue, laser, ultrasound, effect, imaging

Procedia PDF Downloads 395
2767 Comparison of Nucleic Acid Extraction Platforms On Tissue Samples

Authors: Siti Rafeah Md Rafei, Karen Wang Yanping, Park Mi Kyoung

Abstract:

Tissue samples are precious supply for molecular studies or disease identification diagnosed using molecular assays, namely real-time PCR (qPCR). It is critical to establish the most favorable nucleic acid extraction that gives the PCR-amplifiable genomic DNA. Furthermore, automated nucleic acid extraction is an appealing alternative to labor-intensive manual methods. Operational complexity, defined as the number of steps required to obtain an extracted sample, is one of the criteria in the comparison. Here we are comparing the One BioMed’s automated X8 platform with the commercially available manual-operated kits from QIAGEN Mini Kit and Roche. We extracted DNA from rat fresh-frozen tissue (from different type of organs) in the matrices. After tissue pre-treatment, it is added to the One BioMed’s X8 pre-filled cartridge, and the QIAGEN QIAmp column respectively. We found that the results after subjecting the eluates to the Real Time PCR using BIORAD CFX are comparable.

Keywords: DNA extraction, frozen tissue, PCR, qPCR, rat

Procedia PDF Downloads 122
2766 Analysis of the Internal Mechanical Conditions in the Lower Limb Due to External Loads

Authors: Kent Salomonsson, Xuefang Zhao, Sara Kallin

Abstract:

Human soft tissue is loaded and deformed by any activity, an effect known as a stress-strain relationship, and is often described by a load and tissue elongation curve. Several advances have been made in the fields of biology and mechanics of soft human tissue. However, there is limited information available on in vivo tissue mechanical characteristics and behavior. Confident mechanical properties of human soft tissue cannot be extrapolated from e.g. animal testing. Thus, there is need for non invasive methods to analyze mechanical characteristics of soft human tissue. In the present study, the internal mechanical conditions of the lower limb, which is subject to an external load, is studied by use of the finite element method. A detailed finite element model of the lower limb is made possible by use of MRI scans. Skin, fat, bones, fascia and muscles are represented separately and the material properties for them are obtained from literature. Previous studies have been shown to address macroscopic deformation features, e.g. indentation depth, to a large extent. However, the detail in which the internal anatomical features have been modeled does not reveal the critical internal strains that may induce hypoxia and/or eventual tissue damage. The results of the present study reveals that lumped material models, i.e. averaging of the material properties for the different constituents, does not capture regions of critical strains in contrast to more detailed models.

Keywords: FEM, tissue, indentation, properties

Procedia PDF Downloads 335
2765 Comparison of Different DNA Extraction Platforms with FFPE tissue

Authors: Wang Yanping Karen, Mohd Rafeah Siti, Park MI Kyoung

Abstract:

Formalin-fixed paraffin embedded (FFPE) tissue is important in the area of oncological diagnostics. This method of preserving tissues enabling them to be stored easily at ambient temperature for a long time. This decreases the risk of losing the DNA quantity and quality after extraction, reducing sample wastage, and making FFPE more cost effective. However, extracting DNA from FFPE tissue is a challenge as DNA purified is often highly cross-linked, fragmented, and degraded. In addition, this causes problems for many downstream processes. In this study, there will be a comparison of DNA extraction efficiency between One BioMed’s Xceler8 automated platform with commercial available extraction kits (Qiagen and Roche). The FFPE tissue slices were subjected to deparaffinization process, pretreatment and then DNA extraction using the three mentioned platforms. The DNA quantity were determined with real-time PCR (BioRad CFX ) and gel electrophoresis. The amount of DNA extracted with the One BioMed’s X8 platform was found to be comparable with the other two manual extraction kits.

Keywords: DNA extraction, FFPE tissue, qiagen, roche, one biomed X8

Procedia PDF Downloads 69
2764 The Toxicity of Doxorubicin Connected with Nanotransporters

Authors: Iva Blazkova, Amitava Moulick, Vedran Milosavljevic, Pavel Kopel, Marketa Vaculovicova, Vojtech Adam, Rene Kizek

Abstract:

Doxorubicin is one of the most commonly used and the most effective chemotherapeutic drugs. This antracycline drug isolated from the bacteria Streptomyces peuceticus var. caesius is sold under the trade name Adriamycin (hydroxydaunomycin, hydroxydaunorubicin). Doxorubicin is used in single therapy to treat hematological malignancies (blood cancers, leukaemia, lymphoma), many types of carcinoma (solid tumors) and soft tissue sarcomas. It has many serious side effects like nausea and vomiting, hair lost, myelosupression, oral mucositis, skin reactions and redness, but the most serious one is the cardiotoxicity. Because of the risk of heart attack and congestive heart failure, the total dose administered to patients has to be accurately monitored. With the aim to lower the side effects and to targeted delivery of doxorubicin into the tumor tissue, the different nanoparticles are studied. The drug can be bound on a surface of nanoparticle, encapsulated in the inner cavity, or incorporated into the structure of nanoparticle. Among others, carbon nanoparticles (graphene, carbon nanotubes, fullerenes) are highly studied. Besides the number of inorganic nanoparticles, a great potential exhibit also organic ones mainly lipid-based and polymeric nanoparticle. The aim of this work was to perform a toxicity study of free doxorubicin compared to doxorubicin conjugated with various nanotransporters. The effect of liposomes, fullerenes, graphene, and carbon nanotubes on the toxicity was analyzed. As a first step, the binding efficacy of between doxorubicin and the nanotransporter was determined. The highest efficacy was detected in case of liposomes (85% of applied drug was encapsulated) followed by graphene, carbon nanotubes and fullerenes. For the toxicological studies, the chicken embryos incubated under controlled conditions (37.5 °C, 45% rH, rotation every 2 hours) were used. In 7th developmental day of chicken embryos doxorubicin or doxorubicin-nanotransporter complex was applied on the chorioallantoic membrane of the eggs and the viability was analyzed every day till the 17th developmental day. Then the embryos were extracted from the shell and the distribution of doxorubicin in the body was analyzed by measurement of organs extracts using laser induce fluorescence detection. The chicken embryo mortality caused by free doxorubicin (30%) was significantly lowered by using the conjugation with nanomaterials. The highest accumulation of doxorubicin and doxorubicin nanotransporter complexes was observed in the liver tissue

Keywords: doxorubicin, chicken embryos, nanotransporters, toxicity

Procedia PDF Downloads 426
2763 Study of the Design and Simulation Work for an Artificial Heart

Authors: Mohammed Eltayeb Salih Elamin

Abstract:

This study discusses the concept of the artificial heart using engineering concepts, of the fluid mechanics and the characteristics of the non-Newtonian fluid. For the purpose to serve heart patients and improve aspects of their lives and since the Statistics review according to world health organization (WHO) says that heart disease and blood vessels are the first cause of death in the world. Statistics shows that 30% of the death cases in the world by the heart disease, so simply we can consider it as the number one leading cause of death in the entire world is heart failure. And since the heart implantation become a very difficult and not always available, the idea of the artificial heart become very essential. So it’s important that we participate in the developing this idea by searching and finding the weakness point in the earlier designs and hoping for improving it for the best of humanity. In this study a pump was designed in order to pump blood to the human body and taking into account all the factors that allows it to replace the human heart, in order to work at the same characteristics and the efficiency of the human heart. The pump was designed on the idea of the diaphragm pump. Three models of blood obtained from the blood real characteristics and all of these models were simulated in order to study the effect of the pumping work on the fluid. After that, we study the properties of this pump by using Ansys15 software to simulate blood flow inside the pump and the amount of stress that it will go under. The 3D geometries modeling was done using SOLID WORKS and the geometries then imported to Ansys design modeler which is used during the pre-processing procedure. The solver used throughout the study is Ansys FLUENT. This is a tool used to analysis the fluid flow troubles and the general well-known term used for this branch of science is known as Computational Fluid Dynamics (CFD). Basically, Design Modeler used during the pre-processing procedure which is a crucial step before the start of the fluid flow problem. Some of the key operations are the geometry creations which specify the domain of the fluid flow problem. Next is mesh generation which means discretization of the domain to solve governing equations at each cell and later, specify the boundary zones to apply boundary conditions for the problem. Finally, the pre–processed work will be saved at the Ansys workbench for future work continuation.

Keywords: Artificial heart, computational fluid dynamic heart chamber, design, pump

Procedia PDF Downloads 435
2762 Risk of Fatal and Non-Fatal Coronary Heart Disease and Stroke Events among Adult Patients with Hypertension: Basic Markov Model Inputs for Evaluating Cost-Effectiveness of Hypertension Treatment: Systematic Review of Cohort Studies

Authors: Mende Mensa Sorato, Majid Davari, Abbas Kebriaeezadeh, Nizal Sarrafzadegan, Tamiru Shibru, Behzad Fatemi

Abstract:

Markov model, like cardiovascular disease (CVD) policy model based simulation, is being used for evaluating the cost-effectiveness of hypertension treatment. Stroke, angina, myocardial infarction (MI), cardiac arrest, and all-cause mortality were included in this model. Hypertension is a risk factor for a number of vascular and cardiac complications and CVD outcomes. Objective: This systematic review was conducted to evaluate the comprehensiveness of this model across different regions globally. Methods: We searched articles written in the English language from PubMed/Medline, Ovid/Medline, Embase, Scopus, Web of Science, and Google scholar with a systematic search query. Results: Thirteen cohort studies involving a total of 2,165,770 (1,666,554 hypertensive adult population and 499,226 adults with treatment-resistant hypertension) were included in this scoping review. Hypertension is clearly associated with coronary heart disease (CHD) and stroke mortality, unstable angina, stable angina, MI, heart failure (HF), sudden cardiac death, transient ischemic attack, ischemic stroke, subarachnoid hemorrhage, intracranial hemorrhage, peripheral arterial disease (PAD), and abdominal aortic aneurism (AAA). Association between HF and hypertension is variable across regions. Treatment resistant hypertension is associated with a higher relative risk of developing major cardiovascular events and all-cause mortality when compared with non-resistant hypertension. However, it is not included in the previous CVD policy model. Conclusion: The CVD policy model used can be used in most regions for the evaluation of the cost-effectiveness of hypertension treatment. However, hypertension is highly associated with HF in Latin America, the Caribbean, Eastern Europe, and Sub-Saharan Africa. Therefore, it is important to consider HF in the CVD policy model for evaluating the cost-effectiveness of hypertension treatment in these regions. We do not suggest the inclusion of PAD and AAA in the CVD policy model for evaluating the cost-effectiveness of hypertension treatment due to a lack of sufficient evidence. Researchers should consider the effect of treatment-resistant hypertension either by including it in the basic model or during setting the model assumptions.

Keywords: cardiovascular disease policy model, cost-effectiveness analysis, hypertension, systematic review, twelve major cardiovascular events

Procedia PDF Downloads 49
2761 Suitability Evaluation of CNW as Scaffold for Osteoblast

Authors: Hoo Cheol Lee, Dae Seung Kim, Sang Myung Jung, Gwang Heum Yoon, Hwa Sung Shin

Abstract:

Loss of bone tissue can occur due to a bone tissue disease and aging or fracture. Renewable formation of bone is mainly made by its differentiation and metabolism. For this reason, osteoblasts have been studied for regeneration of bone tissue. So, tissue engineering has attracted attention as a recovery means. In tissue engineering, a particularly important factor is a scaffold that supports cell growth. For osteoblast scaffold, we used the cellulose nanowhisker (CNW) extracted from marine organism. CNW is one of an abundant material obtained from a number of plants and animals. CNW is polymer consisting of monomer cellulose and this composition offers biodegradability and biocompatibility to CNW. Mechanical strength of CNW is superior to the existing natural polymers. In addition, substances of marine origin have a low risk of secondary infection by bacteria and pathogen in contrast with those of land-derived. For evaluating its suitability as an osteoblast scaffold, we fabricate CNW film for osteoblast culture and performed the MTT assay and ALP assay to confirm its cytotoxicity and effect on differentiation. Taking together these results, we assessed CNW is a potential candidate of a material for bone tissue regeneration.

Keywords: bone regeneration, cellulose nanowhisker, marine derived material, osteoblast

Procedia PDF Downloads 313
2760 The Effect of 8 Weeks Endurance Training and L-NAME on Apelin in Adipose Tissue, Glucose and Insulin in Elderly Male's Rats

Authors: Asieh Abbassi Daloii, Fatemeh Fani, Ahmad Abdi

Abstract:

Objective: The aim of this study was to determine the effect of 8 weeks endurance training and L-NAME on apelin in adipose tissue, glucose and insulin in elderly male’s rats. Methods: For this purpose, 24 vistar elderly rats with average 20 months old purchased from Razi Institute and transferred to Research Center were randomly divided into four groups: 1. control, 2. training, 3.training and L-NAME and 4. L-NAME. Training protocol performed for 8 weeks and 5 days a week with 75-80 VO2 max. All rats were killed 72 hours after the final training session and after 24 hours of fasting adipose tissue samples were collected and kept in -80. Also, Data was analyzed with One way ANOVA and Tucky in p < 0/05. Results: The results showed that the inhibition of nitric oxide on apelin in adipose tissue of adult male rats after eight weeks of endurance training increased significantly compared to the control group (p < 0.00). Also, the results showed no significant difference between the levels of insulin and glucose groups. Conclusion: It is likely that the increased apelin in adipose tissue in mice independent of insulin and glucose.

Keywords: endurance training, L-NAME, apelin in adipose tissue, elderly male rats

Procedia PDF Downloads 433
2759 The Role of Clinical Pharmacist Intervention in Collaborative Drug Therapy Management to Improve Outcomes and Decrease Hospitalization in Heart Failure Clinic

Authors: Sanaa Mekdad, Leenah Alsayed

Abstract:

Pharmacists play an important role in the CDTM in the care of patients with heart failure (HF). CDTM allows specialized, dedicated clinical pharmacists in a formal agreement in collaborative practice with physicians. Thus, the aim of this study is to investigate the role of cardiology clinical pharmacists in CDTM in decreasing hospitalization and cost. We studied patients with left ventricular systolic dysfunction in a cluster-randomized selection in a tertiary care center. We allocated 296 patients to pharmacist intervention from 1480 patients. Results: With an acceptance rate of 86%, we documented 696 interventions carried out by clinical pharmacists in cardiology. The average intervention was 2.4 patients, and the admission after interventions decreased from 0.79 to. 0.24 (p value = 0.001). Conclusions: In HF CDTM, clinical pharmacists play a crucial role in enhancing medication management, patient education, and lifestyle modification of patients with chronic heart failure. These efforts improve patients' outcomes and lower costs by reducing hospitalization and other associated expenses.

Keywords: cardiology, medication management, heart failure, outpatient therapy, pharmacist-based services, chronic heart failure, heart failure recommendations, CDTM, Middle East, pharmacist-based services, quality of life, pharmacist

Procedia PDF Downloads 46
2758 TNF-Alpha and MDA Levels in Hearts of Cholesterol-Fed Rats Supplemented with Extra Virgin Olive Oil or Sunflower Oil, in Either Commercial or Modified Forms

Authors: Ageliki I. Katsarou, Andriana C. Kaliora, Antonia Chiou, Apostolos Papalois, Nick Kalogeropoulos, Nikolaos K. Andrikopoulos

Abstract:

Oxidative stress is a major mechanism underlying CVDs while inflammation, an intertwined process with oxidative stress, is also linked to CVDs. Extra virgin olive oil (EVOO) is widely known to play a pivotal role in CVD prevention and CVD reduction. However, in most studies, olive oil constituents are evaluated individually and not as part of the native food, hence potential synergistic effects as drivers of EVOO beneficial properties may be underestimated. In this study, EVOO lipidic and polar phenolics fractions were evaluated for their effect on inflammatory (TNF-alpha) and oxidation (malondialdehyde/MDA) markers, in cholesterol-fed rats. Thereat, oils with discernible lipidic profile and polar phenolic content were used. Wistar rats were fed on either a high-cholesterol diet (HCD) or a HCD supplemented with oils, either commercially available, i.e. EVOO, sunflower oil (SO), or modified as to their polar phenol content, i.e. phenolics deprived-EVOO (EVOOd), SO enriched with the EVOO phenolics (SOe). After 9 weeks of dietary intervention, heart and blood samples were collected. HCD induced dylipidemia shown by increase in serum total cholesterol, low-density lipoprotein cholesterol (LDL-c) and triacylglycerols. Heart tissue has been affected by dyslipidemia; oxidation was indicated by increase in MDA in cholesterol-fed rats and inflammation by increase in TNF-alpha. In both cases, this augmentation was attenuated in EVOO and SOe diets. With respect to oxidation, SO enrichment with the EVOO phenolics brought its lipid peroxidation levels as low as in EVOO-fed rats. This suggests that phenolic compounds may act as antioxidant agents in rat heart. A possible mechanism underlying this activity may be the protective effect of phenolics in mitochondrial membrane against oxidative damage. This was further supported by EVOO/EVOOd comparison with the former presenting lower heart MDA content. As for heart inflammation, phenolics naturally present in EVOO as well as phenolics chemically added in SO, exhibited quenching abilities in heart TNF-alpha levels of cholesterol-fed rats. TNF-alpha may have played a causative role in oxidative stress induction while the opposite may have also happened, hence setting up a vicious cycle. Overall, diet supplementation with EVOO or SOe attenuated hypercholesterolemia-induced increase in MDA and TNF-alpha in Wistar rat hearts. This is attributed to phenolic compounds either naturally existing in olive oil or as fortificants in seed oil.

Keywords: extra virgin olive oil, hypercholesterolemic rats, MDA, polar phenolics, TNF-alpha

Procedia PDF Downloads 468
2757 Non-Invasive Imaging of Human Tissue Using NIR Light

Authors: Ashwani Kumar

Abstract:

Use of NIR light for imaging the biological tissue and to quantify its optical properties is a good choice over other invasive methods. Optical tomography involves two steps. One is the forward problem and the other is the reconstruction problem. The forward problem consists of finding the measurements of transmitted light through the tissue from source to detector, given the spatial distribution of absorption and scattering properties. The second step is the reconstruction problem. In X-ray tomography, there is standard method for reconstruction called filtered back projection method or the algebraic reconstruction methods. But this method cannot be applied as such, in optical tomography due to highly scattering nature of biological tissue. A hybrid algorithm for reconstruction has been implemented in this work which takes into account the highly scattered path taken by photons while back projecting the forward data obtained during Monte Carlo simulation. The reconstructed image suffers from blurring due to point spread function.

Keywords: NIR light, tissue, blurring, Monte Carlo simulation

Procedia PDF Downloads 463
2756 Low Cost Technique for Measuring Luminance in Biological Systems

Authors: N. Chetty, K. Singh

Abstract:

In this work, the relationship between the melanin content in a tissue and subsequent absorption of light through that tissue was determined using a digital camera. This technique proved to be simple, cost effective, efficient and reliable. Tissue phantom samples were created using milk and soy sauce to simulate the optical properties of melanin content in human tissue. Increasing the concentration of soy sauce in the milk correlated to an increase in melanin content of an individual. Two methods were employed to measure the light transmitted through the sample. The first was direct measurement of the transmitted intensity using a conventional lux meter. The second method involved correctly calibrating an ordinary digital camera and using image analysis software to calculate the transmitted intensity through the phantom. The results from these methods were then graphically compared to the theoretical relationship between the intensity of transmitted light and the concentration of absorbers in the sample. Conclusions were then drawn about the effectiveness and efficiency of these low cost methods.

Keywords: tissue phantoms, scattering coefficient, albedo, low-cost method

Procedia PDF Downloads 248
2755 Development of Numerical Model to Compute Water Hammer Transients in Pipe Flow

Authors: Jae-Young Lee, Woo-Young Jung, Myeong-Jun Nam

Abstract:

Water hammer is a hydraulic transient problem which is commonly encountered in the penstocks of hydropower plants. The numerical model was developed to estimate the transient behavior of pressure waves in pipe systems. The computational algorithm was proposed to model the water hammer phenomenon in a pipe system with pump shutdown at midstream and sudden valve closure at downstream. To predict the pressure head and flow velocity as a function of time as a result of rapidly closing a valve and pump shutdown, two boundary conditions at the ends considering pump operation and valve control can be implemented as specified equations of the pressure head and flow velocity based on the characteristics method. It was shown that the effects of transient flow make it determine the needs for protection devices, such as surge tanks, surge relief valves, or air valves, at various points in the system against overpressure and low pressure. It produced reasonably good performance with the results of the proposed transient model for pipeline systems. The proposed numerical model can be used as an efficient tool for the safety assessment of hydropower plants due to water hammer.

Keywords: water hammer, hydraulic transient, pipe systems, characteristics method

Procedia PDF Downloads 104
2754 Long-Term Results of Surgical Treatment of Atrial Fibrillation in Patients with Coronary Heart Disease: One Center Experience

Authors: Emil Sakharov, Alex Zotov, Ilkin Osmanov, Oleg Shelest, Aleksander Troitskiy, Robert Khabazov

Abstract:

Objective: Since 2015, our center has been actively implementing methods of surgical correction of atrial fibrillation, in particular, in patients with coronary heart disease. The study presents a comparative analysis of the late postoperative period in patients with coronary artery bypass grafting and atrial fibrillation. Methods: The study included 150 patients with ischemic heart disease and atrial fibrillation for the period from 2015 to 2021. Patients were divided into 2 groups. The first group is represented by patients with ischemic heart disease and atrial fibrillation who underwent coronary bypass surgery and surgical correction of atrial fibrillation (N=50). The second group is represented by patients with ischemic heart disease and atrial fibrillation who underwent only myocardial revascularization (N=100). Patients were comparable in age, gender, and initial severity of the condition. Among the patients in group 1 there were 82% were men, while in the second group, their number was 75%. Among the patients of the first group, there were 36% with persistent atrial fibrillation, 20% with long-term persistent atrial fibrillation. In the second group, 10% with persistent atrial fibrillation and 17% with long-term persistent atrial fibrillation. Results: Average follow-up for groups 1 and 2 amounted to 47 months. There were no complications in group 1, such as bleeding and stroke. There was only 1 patient in group 1, who had died from cardiovascular disease. Freedom of atrial fibrillation was in 82% without AADs therapy. In group 2 there were 8 patients who had died from cardiovascular diseases and total freedom of atrial fibrillation was in 35% of patients, among which 42.8% had additional AADs therapy. Follow-up data are presented in Table 2. Progression of heart failure was observed in 3% in group 1 and 7% in group 2. Combined endpoints (recurrence of AF, stroke, progression of heart failure, myocardial infarction) were achieved in 16% in group 1 and 34% in group 2, respectively. Freedom from atrial fibrillation without antiarrhythmic therapy was 82% for group 1 and 35% for group 2. In the first group, there is a more pronounced decrease in heart failure rates. Deaths from cardiovascular causes were recorded in 2% for group 1 and 7% for group 2. Conclusion: Surgical treatment of atrial fibrillation helps to reduce adverse complications in the late postoperative period and contributes to the regression of heart failure.

Keywords: atrial fibrillation, coronary artery bypass grafting, ischaemic heart disease, heart failure

Procedia PDF Downloads 84
2753 Impact of Pediatric Cardiac Rehabilitation on the Physical Condition of Children with Congenital Heart Defects

Authors: Hady Atef Labib

Abstract:

Pediatric cardiac rehabilitation has the potential to benefit many children with congenital heart defects (CHD). Instead of excellent surgical results most of children usually present with a depression of physical condition so early rehabilitation program is recommended to avoid that decline in physical tolerance and prevent any post surgical complications. Unfortunately, the limited experience with and availability of these programs has caused the benefits of cardiac rehabilitation to be unavailable to most children with CHD. Therefore, it is recommended to study that field in more detail and apply it on wider scale.

Keywords: pediatric cardiac rehabilitation, congenital heart disease, quality of life, pediatric

Procedia PDF Downloads 343
2752 Piled Critical Size Bone-Biomimetic and Biominerizable Nanocomposites: Formation of Bioreactor-Induced Stem Cell Gradients under Perfusion and Compression

Authors: W. Baumgartner, M. Welti, N. Hild, S. C. Hess, W. J. Stark, G. Meier Bürgisser, P. Giovanoli, J. Buschmann

Abstract:

Perfusion bioreactors are used to solve problems in tissue engineering in terms of sufficient nutrient and oxygen supply. Such problems especially occur in critical size grafts because vascularization is often too slow after implantation ending up in necrotic cores. Biominerizable and biocompatible nanocomposite materials are attractive and suitable scaffold materials for bone tissue engineering because they offer mineral components in organic carriers – mimicking natural bone tissue. In addition, human adipose derived stem cells (ASCs) can potentially be used to increase bone healing as they are capable of differentiating towards osteoblasts or endothelial cells among others. In the present study, electrospun nanocomposite disks of poly-lactic-co-glycolic acid and amorphous calcium phosphate nanoparticles (PLGA/a-CaP) were seeded with human ASCs and eight disks were stacked in a bioreactor running with normal culture medium (no differentiation supplements). Under continuous perfusion and uniaxial cyclic compression, load-displacement curves as a function of time were assessed. Stiffness and energy dissipation were recorded. Moreover, stem cell densities in the layers of the piled scaffold were determined as well as their morphologies and differentiation status (endothelial cell differentiation, chondrogenesis and osteogenesis). While the stiffness of the cell free constructs increased over time caused by the transformation of the a-CaP nanoparticles into flake-like apatite, ASC-seeded constructs showed a constant stiffness. Stem cell density gradients were histologically determined with a linear increase in the flow direction from the bottom to the top of the 3.5 mm high pile (r2 > 0.95). Cell morphology was influenced by the flow rate, with stem cells getting more roundish at higher flow rates. Less than 1 % osteogenesis was found upon osteopontin immunostaining at the end of the experiment (9 days), while no endothelial cell differentiation and no chondrogenesis was triggered under these conditions. All ASCs had mainly remained in their original pluripotent status within this time frame. In summary, we have fabricated a critical size bone graft based on a biominerizable bone-biomimetic nanocomposite with preserved stiffness when seeded with human ASCs. The special feature of this bone graft was that ASC densities inside the piled construct varied with a linear gradient, which is a good starting point for tissue engineering interfaces such as bone-cartilage where the bone tissue is cell rich while the cartilage exhibits low cell densities. As such, this tissue-engineered graft may act as a bone-cartilage interface after the corresponding differentiation of the ASCs.

Keywords: bioreactor, bone, cartilage, nanocomposite, stem cell gradient

Procedia PDF Downloads 283
2751 A 3D Bioprinting System for Engineering Cell-Embedded Hydrogels by Digital Light Processing

Authors: Jimmy Jiun-Ming Su, Yuan-Min Lin

Abstract:

Bioprinting has been applied to produce 3D cellular constructs for tissue engineering. Microextrusion printing is the most common used method. However, printing low viscosity bioink is a challenge for this method. Herein, we developed a new 3D printing system to fabricate cell-laden hydrogels via a DLP-based projector. The bioprinter is assembled from affordable equipment including a stepper motor, screw, LED-based DLP projector, open source computer hardware and software. The system can use low viscosity and photo-polymerized bioink to fabricate 3D tissue mimics in a layer-by-layer manner. In this study, we used gelatin methylacrylate (GelMA) as bioink for stem cell encapsulation. In order to reinforce the printed construct, surface modified hydroxyapatite has been added in the bioink. We demonstrated the silanization of hydroxyapatite could improve the crosslinking between the interface of hydroxyapatite and GelMA. The results showed that the incorporation of silanized hydroxyapatite into the bioink had an enhancing effect on the mechanical properties of printed hydrogel, in addition, the hydrogel had low cytotoxicity and promoted the differentiation of embedded human bone marrow stem cells (hBMSCs) and retinal pigment epithelium (RPE) cells. Moreover, this bioprinting system has the ability to generate microchannels inside the engineered tissues to facilitate diffusion of nutrients. We believe this 3D bioprinting system has potential to fabricate various tissues for clinical applications and regenerative medicine in the future.

Keywords: bioprinting, cell encapsulation, digital light processing, GelMA hydrogel

Procedia PDF Downloads 149
2750 The Most Desirable Individual Relationship

Authors: Ali Babaei

Abstract:

There is a significant relationship between Soul Faculties and human relationships. Man has at least three levels of relationship according to three levels of his Faculties: individual (with himself), dual (with another) and collective (with others). Since all human actions are organized by the type of use of their internal faculties, their "hierarchy of relations" is related to the "hierarchy of their Faculties." In the final explanation based on the ontology of Islamic wisdom, one can consider the hierarchy of human Faculties in three levels: 1. senses, 2. intellect and heart, and 3. Soul. The best relationship, in the individual one is that every human being, with healthy senses, achieves both the intellectual growth and the perfection of the heart, which we call "Clear-headed" and "Good-hearted.” The result of human evolution in this two aspects will lead to the development of a powerful personality which can be interpreted as "spiritual prosperity"; having a great soul is the result of such evolution. A smart brain without a "Good-heart"ince can lead to criminality; and mere "Good-heart"ince" without "Clear-head"ince leads to "naivety". “clear-head”ince is achieved through thoughtfulness and study, and "Good-heart"ince through love and worship. So the best way to achieve perfection in a personal relationship is to have a dependable appearance, a coherent thinking

Keywords: Ontology , good-heartince, wisdom, relationship, clear-head”ince, criminality, naivety

Procedia PDF Downloads 108
2749 Correlation Between Diastolic Function and Lower GLS in Hypertensive Patients

Authors: A. Kherraf, S. Ouarrak, L. Azzouzi, R. Habbal

Abstract:

Introduction: Preserved LVEF heart failure is an important cause of mortality and morbidity in hypertensive patients. A strong correlation between impaired diastolic function and longitudinal systolic dysfunction. could have several explanations, first, the diastole is an energy dependent process, especially during its first phase, it also includes active systolic components during the phase of iso volumetric relaxation, in addition, the impairment of the intrinsic myocytic function is part of hypertensive pathology as evidenced by recent studies. METHODS AND MATERIALS: This work consists of performing in a series of 333 hypertensive patients (aged 25 to 75 years) a complete echocardiographic study, including LVEF by Simpson biplane method, the calculation of the indexed left ventricular mass, the analysis of the diastolic function, and finally, the study of the longitudinal deformation of the LV by the technique of speckletracking (calculation of the GLS). Patients with secondary hypertension, leaky or stenosing valve disease, arrhythmia, and a history of coronary insufficiency were excluded from this study. RESULTS: Of the 333 hypertensive patients, 225 patients (67.5%) had impaired diastolic function, of which 60 patients (18%) had high filling pressures. 49.39% had echocardigraphic HVG, Almost all of these patients (60 patients) had low GLS. There is a statistically very significant relationship between lower GLS and increased left ventricular filling pressures in hypertensive patients. These results suggest that increased filling pressures are closely associated with atrioventricular interaction in patients with hypertension, with a strong correlation with impairment of longitudinal systolic function and diastolic function CONCLUSION: Overall, a linear relationship is established between increased left ventricular mass, diastolic dysfunction, and longitudinal LV systolic dysfunction

Keywords: hypertension, diastolic function, left ventricle, heart failure

Procedia PDF Downloads 103
2748 [Keynote Talk]: Mathematical and Numerical Modelling of the Cardiovascular System: Macroscale, Mesoscale and Microscale Applications

Authors: Aymen Laadhari

Abstract:

The cardiovascular system is centered on the heart and is characterized by a very complex structure with different physical scales in space (e.g. micrometers for erythrocytes and centimeters for organs) and time (e.g. milliseconds for human brain activity and several years for development of some pathologies). The development and numerical implementation of mathematical models of the cardiovascular system is a tremendously challenging topic at the theoretical and computational levels, inducing consequently a growing interest over the past decade. The accurate computational investigations in both healthy and pathological cases of processes related to the functioning of the human cardiovascular system can be of great potential in tackling several problems of clinical relevance and in improving the diagnosis of specific diseases. In this talk, we focus on the specific task of simulating three particular phenomena related to the cardiovascular system on the macroscopic, mesoscopic and microscopic scales, respectively. Namely, we develop numerical methodologies tailored for the simulation of (i) the haemodynamics (i.e., fluid mechanics of blood) in the aorta and sinus of Valsalva interacting with highly deformable thin leaflets, (ii) the hyperelastic anisotropic behaviour of cardiomyocytes and the influence of calcium concentrations on the contraction of single cells, and (iii) the dynamics of red blood cells in microvasculature. For each problem, we present an appropriate fully Eulerian finite element methodology. We report several numerical examples to address in detail the relevance of the mathematical models in terms of physiological meaning and to illustrate the accuracy and efficiency of the numerical methods.

Keywords: finite element method, cardiovascular system, Eulerian framework, haemodynamics, heart valve, cardiomyocyte, red blood cell

Procedia PDF Downloads 227
2747 The Influence of Alginate Microspheres Modified with DAT on the Proliferation and Adipogenic Differentiation of ASCs

Authors: Shin-Yi Mao, Jiashing Yu

Abstract:

Decellularized adipose tissue (DAT) has received lots of attention as biological scaffolds recently. DAT that extracted from the extracellular matrix (ECM) of adipose tissues holds great promise as a xenogeneic biomaterial for tissue engineering and regenerative medicine. In our study, 2-D DATsol film was fabricated to enhance cell adhesion, proliferation, and differentiation of ASCs in vitro. DAT was also used to modify alginate for improvement of cell adhesion. Alginate microspheres modified with DAT were prepared by Nisco. These microspheres could provide a highly supportive 3-D environment for ASCs. In our works, ASCs were immobilized in alginate microspheres modified with DAT to promoted cell adhesion and adipogenic differentiation. Accordingly, we hypothesize that tissue regeneration in vivo could be promoted with the aid of modified microspheres in future.

Keywords: adipose stem cells, decellularize adipose tissue, Alginate, microcarries

Procedia PDF Downloads 416