Search results for: clinical monitoring
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6266

Search results for: clinical monitoring

6056 Survey on Resilience of Chinese Nursing Interns: A Cross-Sectional Study

Authors: Yutong Xu, Wanting Zhang, Jia Wang, Zihan Guo, Weiguang Ma

Abstract:

Background: The resilience education of intern nursing students has significant implications for the development and improvement of the nursing workforce. The clinical internship period is a critical time for enhancing resilience. Aims: To evaluate the resilience level of Chinese nursing interns and identify the factors affecting resilience early in their careers. Methods: The cross-sectional study design was adopted. From March 2022 to May 2023, 512 nursing interns in tertiary care hospitals were surveyed online with the Connor-Davidson Resilience Scale, the Clinical Learning Environment scale for Nurse, and the Career Adapt-Abilities Scale. Structural equation modeling was used to clarify the relationships among these factors. Indirect effects were tested using bootstrapped Confidence Intervals. Results: The nursing interns showed a moderately high level of resilience[M(SD)=70.15(19.90)]. Gender, scholastic attainment, had a scholarship, career adaptability and clinical learning environment were influencing factors of nursing interns’ resilience. Career adaptability and clinical learning environment positively and directly affected their resilience level (β = 0.58, 0.12, respectively, p<0.01). career adaptability also positively affected career adaptability (β = 0.26, p < 0.01), and played a fully mediating role in the relationship between clinical learning environment and resilience. Conclusion: Career adaptability can enhance the influence of clinical learning environment on resilience. The promotion of career adaptability and the clinical teaching environment should be the potential strategies for nursing interns to improve their resilience, especially for those female nursing interns with low academic performance. Implications for Nursing Educators Nursing educators should pay attention to the cultivation of nursing students' resilience; for example, by helping them integrate to the clinical learning environment and improving their career adaptability. Reporting Method: The STROBE criteria were used to report the results of the observations critically. Patient or Public Contribution No patient or public contribution.

Keywords: resilience, clinical learning environment, career adaptability, nursing interns

Procedia PDF Downloads 41
6055 Rethinking of Self-Monitoring and Self-Response Roles in Teaching Grammar Knowledge to Iranian EFL Learners

Authors: Gholam Reza Parvizi, Ali Reza Kargar, Amir Arani

Abstract:

In the present days, learning and teaching researchers have emphasized the role which teachers, tutors, and trainers’ constraint knowledge treat in resizing and trimming what they perform in educational atmosphere. Regarding English language as subject to teaching, although the prominence of instructor’s knowledge about grammar has also been stressed, but the lack of empirical insights into the relationship between teacher’ self-monitoring and self-response of grammar knowledge have been observed. With particular attention to the grammar this article indicates and discusses information obtained self- feedback and conversing teachers of a kind who backwash the issue. The result of the study indicates that enabling teachers to progress and maintain a logical and realistic awareness of their knowledge about grammar have to be prominent goal for teachers’ education and development programs.

Keywords: grammar knowledge, self-monitoring, self-response, teaching grammar, language teaching program

Procedia PDF Downloads 527
6054 System for Monitoring Marine Turtles Using Unstructured Supplementary Service Data

Authors: Luís Pina

Abstract:

The conservation of marine biodiversity keeps ecosystems in balance and ensures the sustainable use of resources. In this context, technological resources have been used for monitoring marine species to allow biologists to obtain data in real-time. There are different mobile applications developed for data collection for monitoring purposes, but these systems are designed to be utilized only on third-generation (3G) phones or smartphones with Internet access and in rural parts of the developing countries, Internet services and smartphones are scarce. Thus, the objective of this work is to develop a system to monitor marine turtles using Unstructured Supplementary Service Data (USSD), which users can access through basic mobile phones. The system aims to improve the data collection mechanism and enhance the effectiveness of current systems in monitoring sea turtles using any type of mobile device without Internet access. The system will be able to report information related to the biological activities of marine turtles. Also, it will be used as a platform to assist marine conservation entities to receive reports of illegal sales of sea turtles. The system can also be utilized as an educational tool for communities, providing knowledge and allowing the inclusion of communities in the process of monitoring marine turtles. Therefore, this work may contribute with information to decision-making and implementation of contingency plans for marine conservation programs.

Keywords: GSM, marine biology, marine turtles, unstructured supplementary service data (USSD)

Procedia PDF Downloads 182
6053 Cost-Effective Indoor-Air Quality (IAQ) Monitoring via Cavity Enhanced Photoacoustic Technology

Authors: Jifang Tao, Fei Gao, Hong Cai, Yuan Jin Zheng, Yuan Dong Gu

Abstract:

Photoacoustic technology is used to measure effect absorption of a light by means of acoustic detection, which provides a high sensitive, low-cross response, cost-effective solution for gas molecular detection. In this paper, we proposed an integrated photoacoustic sensor for Indoor-air quality (IAQ) monitoring. The sensor consists of an acoustically resonant cavity, a high silicon acoustic transducer chip, and a low-cost light source. The light is modulated at the resonant frequency of the cavity to create an enhanced periodic heating and result in an amplified acoustic pressure wave. The pressure is readout by a novel acoustic transducer with low noise. Based on this photoacoustic sensor, typical indoor gases, including CO2, CO, O2, and H2O have been successfully detected, and their concentration are also evaluated with very high accuracy. It has wide potential applications in IAQ monitoring for agriculture, food industry, and ventilation control systems used in public places, such as schools, hospitals and airports.

Keywords: indoor-air quality (IAQ) monitoring, photoacoustic gas sensor, cavity enhancement, integrated gas sensor

Procedia PDF Downloads 634
6052 An Open-Label Phase I Clinical Study: Safety, Tolerability and Pharmacodynamics of Mutant Collagenase Injection in Adults for Localized Fat Reduction

Authors: Yong Cang

Abstract:

RJV001 is a subcutaneous injection containing mutated recombinant Collagenase H (ColH), leading to disruption of collagen matrix in adipose tissue and programmed cell death of adipocytes. Here we reported our clinical investigation of the safety, tolerance and pharmacodynamics of localized RJV001 injection into healthy human abdominal fat tissues (NCT04821648, Arizona Research Center). Investigate the safety, tolerance and clinical pharmacodynamics of subcutaneous RJV001 in humans. In the dose-escalating study, 18 subjects completed the study, 100% female, 78% white, with a mean age of 42[±9.9]. All three tested dose (0.05, 0.075 and 0.15 mg/injection), up to 30 injections, were safe and well-tolerated. Bruising and tenderness to palpation, mild to moderate, were the most frequent local skin reactions but nearly all resolved within 30 days. Additionally, physician-monitored ultrasound measurement showed that a reduction in abdominal fat tissue thickness was consistently observed in Cohort C (0.075, 0.15 mg/injection, 30injections), with a mean reduction of 7.37 [± 2.020] mm. Based on this clinical study, RJV001 has been advanced to phase II clinical studies. In the dose-escalating study, subcutaneously administered RJV001 was safe and well-tolerated in healthy adults up to 0.15 mg/injection, 30 injections. Fat reduction and adipocytolysis were observed by ultrasound measurements and histological analysis for exploratory purposes.

Keywords: fat reduction, mutant collagenase, clinical trial, subcutaneous injection

Procedia PDF Downloads 80
6051 Relocation of the Air Quality Monitoring Stations Network for Aburrá Valley Based on Local Climatic Zones

Authors: Carmen E. Zapata, José F. Jiménez, Mauricio Ramiréz, Natalia A. Cano

Abstract:

The majority of the urban areas in Latin America face the challenges associated with city planning and development problems, attributed to human, technical, and economical factors; therefore, we cannot ignore the issues related to climate change because the city modifies the natural landscape in a significant way transforming the radiation balance and heat content in the urbanized areas. These modifications provoke changes in the temperature distribution known as “the heat island effect”. According to this phenomenon, we have the need to conceive the urban planning based on climatological patterns that will assure its sustainable functioning, including the particularities of the climate variability. In the present study, it is identified the Local Climate Zones (LCZ) in the Metropolitan Area of the Aburrá Valley (Colombia) with the objective of relocate the air quality monitoring stations as a partial solution to the problem of how to measure representative air quality levels in a city for a local scale, but with instruments that measure in the microscale.

Keywords: air quality, monitoring, local climatic zones, valley, monitoring stations

Procedia PDF Downloads 242
6050 The 6Rs of Radiobiology in Photodynamic Therapy: Review

Authors: Kave Moloudi, Heidi Abrahamse, Blassan P. George

Abstract:

Radiotherapy (RT) and photodynamic therapy (PDT) are both forms of cancer treatment that aim to kill cancer cells while minimizing damage to healthy tissue. The similarity between RT and PDT lies in their mechanism of action. Both treatments use energy to damage cancer cells. RT uses high-energy radiation to damage the DNA of cancer cells, while PDT uses light energy to activate a photosensitizing agent, which produces reactive oxygen species (ROS) that damage the cancer cells. Both treatments require careful planning and monitoring to ensure the correct dose is delivered to the tumor while minimizing damage to surrounding healthy tissue. They are also often used in combination with other treatments, such as surgery or chemotherapy, to improve overall outcomes. However, there are also significant differences between RT and PDT. For example, RT is a non-invasive treatment that can be delivered externally or internally, while PDT requires the injection of a photosensitizing agent and the use of a specialized light source to activate it. Additionally, the side effects and risks associated with each treatment can vary. In this review, we focus on generalizing the 6Rs of radiobiology in PDT, which can open a window for the clinical application of Radio-photodynamic therapy with minimum side effects. Furthermore, this review can open new insight to work on and design new radio-photosensitizer agents in Radio-photodynamic therapy.

Keywords: radiobiology, photodynamic therapy, radiotherapy, 6Rs in radiobiology, ROS, DNA damages, cellular and molecular mechanism, clinical application.

Procedia PDF Downloads 56
6049 Metal-Oxide-Semiconductor-Only Process Corner Monitoring Circuit

Authors: Davit Mirzoyan, Ararat Khachatryan

Abstract:

A process corner monitoring circuit (PCMC) is presented in this work. The circuit generates a signal, the logical value of which depends on the process corner only. The signal can be used in both digital and analog circuits for testing and compensation of process variations (PV). The presented circuit uses only metal-oxide-semiconductor (MOS) transistors, which allow increasing its detection accuracy, decrease power consumption and area. Due to its simplicity the presented circuit can be easily modified to monitor parametrical variations of only n-type and p-type MOS (NMOS and PMOS, respectively) transistors, resistors, as well as their combinations. Post-layout simulation results prove correct functionality of the proposed circuit, i.e. ability to monitor the process corner (equivalently die-to-die variations) even in the presence of within-die variations.

Keywords: detection, monitoring, process corner, process variation

Procedia PDF Downloads 496
6048 A Vehicle Monitoring System Based on the LoRa Technique

Authors: Chao-Linag Hsieh, Zheng-Wei Ye, Chen-Kang Huang, Yeun-Chung Lee, Chih-Hong Sun, Tzai-Hung Wen, Jehn-Yih Juang, Joe-Air Jiang

Abstract:

Air pollution and climate warming become more and more intensified in many areas, especially in urban areas. Environmental parameters are critical information to air pollution and weather monitoring. Thus, it is necessary to develop a suitable air pollution and weather monitoring system for urban areas. In this study, a vehicle monitoring system (VMS) based on the IoT technique is developed. Cars are selected as the research tool because it can reach a greater number of streets to collect data. The VMS can monitor different environmental parameters, including ambient temperature and humidity, and air quality parameters, including PM2.5, NO2, CO, and O3. The VMS can provide other information, including GPS signals and the vibration information through driving a car on the street. Different sensor modules are used to measure the parameters and collect the measured data and transmit them to a cloud server through the LoRa protocol. A user interface is used to show the sensing data storing at the cloud server. To examine the performance of the system, a researcher drove a Nissan x-trail 1998 to the area close to the Da’an District office in Taipei to collect monitoring data. The collected data are instantly shown on the user interface. The four kinds of information are provided by the interface: GPS positions, weather parameters, vehicle information, and air quality information. With the VMS, users can obtain the information regarding air quality and weather conditions when they drive their car to an urban area. Also, government agencies can make decisions on traffic planning based on the information provided by the proposed VMS.

Keywords: LoRa, monitoring system, smart city, vehicle

Procedia PDF Downloads 353
6047 Efficient Deep Neural Networks for Real-Time Strawberry Freshness Monitoring: A Transfer Learning Approach

Authors: Mst. Tuhin Akter, Sharun Akter Khushbu, S. M. Shaqib

Abstract:

A real-time system architecture is highly effective for monitoring and detecting various damaged products or fruits that may deteriorate over time or become infected with diseases. Deep learning models have proven to be effective in building such architectures. However, building a deep learning model from scratch is a time-consuming and costly process. A more efficient solution is to utilize deep neural network (DNN) based transfer learning models in the real-time monitoring architecture. This study focuses on using a novel strawberry dataset to develop effective transfer learning models for the proposed real-time monitoring system architecture, specifically for evaluating and detecting strawberry freshness. Several state-of-the-art transfer learning models were employed, and the best performing model was found to be Xception, demonstrating higher performance across evaluation metrics such as accuracy, recall, precision, and F1-score.

Keywords: strawberry freshness evaluation, deep neural network, transfer learning, image augmentation

Procedia PDF Downloads 56
6046 Development of a Real Time Axial Force Measurement System and IoT-Based Monitoring for Smart Bearing

Authors: Hassam Ahmed, Yuanzhi Liu, Yassine Selami, Wei Tao, Hui Zhao

Abstract:

The purpose of this research is to develop a real time axial force measurement system for a smart bearing through the use of strain-gauges, whereby the data acquisition is performed by an Arduino microcontroller due to its easy manipulation and low-cost. The measured signal is acquired and then discretized using a Wheatstone Bridge and an Analog-Digital Converter (ADC) respectively. For bearing monitoring, a real time monitoring system based on Internet of things (IoT) and Bluetooth were developed. Experimental tests were performed on a bearing within a force range up to 600 kN. The experimental results show that there is a proportional linear relationship between the applied force and the output voltage, and the error R squared is within 0.9878 based on the regression analysis.

Keywords: bearing, force measurement, IoT, strain gauge

Procedia PDF Downloads 111
6045 A Leaf-Patchable Reflectance Meter for in situ Continuous Monitoring of Chlorophyll Content

Authors: Kaiyi Zhang, Wenlong Li, Haicheng Li, Yifei Luo, Zheng Li, Xiaoshi Wang, Xiaodong Chen

Abstract:

Plant wearable sensors facilitate the real-time monitoring of plant physiological status. In situ monitoring of the plant chlorophyll content over days could provide valuable information on the photosynthetic capacity, nitrogen content, and general plant health. However, it cannot be achieved by current chlorophyll measuring methods. Here, a miniaturized and plant-wearable chlorophyll meter was developed for rapid, non-destructive, in situ, and long-term chlorophyll monitoring. This reflectance-based chlorophyll sensor with 1.5 mm thickness and 0.2 g weight (1000 times lighter than the commercial chlorophyll meter), includes a light emitting diode (LED) and two symmetric photodetectors (PDs) on a flexible substrate and is patched onto the leaf upper epidermis with a conformal light guiding layer. A chlorophyll content index (CCI) calculated based on this sensor shows a better linear relationship with the leaf chlorophyll content (r² > 0.9) than the traditional chlorophyll meter. This meter can wirelessly communicate with a smartphone to monitor the leaf chlorophyll change under various stresses and indicate the unhealthy status of plants for long-term application of plants under various stresses earlier than chlorophyll meter and naked-eye observation. This wearable chlorophyll sensing patch is promising in smart and precision agriculture.

Keywords: plant wearable sensors, reflectance-based measurements, chlorophyll content monitoring, smart agriculture

Procedia PDF Downloads 58
6044 To Design an Architectural Model for On-Shore Oil Monitoring Using Wireless Sensor Network System

Authors: Saurabh Shukla, G. N. Pandey

Abstract:

In recent times, oil exploration and monitoring in on-shore areas have gained much importance considering the fact that in India the oil import is 62 percent of the total imports. Thus, architectural model like wireless sensor network to monitor on-shore deep sea oil well is being developed to get better estimate of the oil prospects. The problem we are facing nowadays that we have very few restricted areas of oil left today. Countries like India don’t have much large areas and resources for oil and this problem with most of the countries that’s why it has become a major problem when we are talking about oil exploration in on-shore areas also the increase of oil prices has further ignited the problem. For this the use of wireless network system having relative simplicity, smallness in size and affordable cost of wireless sensor nodes permit heavy deployment in on-shore places for monitoring oil wells. Deployment of wireless sensor network in large areas will surely reduce the cost it will be very much cost effective. The objective of this system is to send real time information of oil monitoring to the regulatory and welfare authorities so that suitable action could be taken. This system architecture is composed of sensor network, processing/transmission unit and a server. This wireless sensor network system could remotely monitor the real time data of oil exploration and monitoring condition in the identified areas. For wireless sensor networks, the systems are wireless, have scarce power, are real-time, utilize sensors and actuators as interfaces, have dynamically changing sets of resources, aggregate behaviour is important and location is critical. In this system a communication is done between the server and remotely placed sensors. The server gives the real time oil exploration and monitoring conditions to the welfare authorities.

Keywords: sensor, wireless sensor network, oil, sensor, on-shore level

Procedia PDF Downloads 414
6043 A Wireless Sensor Network Protocol for a Car Parking Space Monitoring System

Authors: Jung-Ho Moon, Myung-Gon Yoon, Tae Kwon Ha

Abstract:

This paper presents a wireless sensor network protocol for a car parking monitoring system. A wireless sensor network for the purpose is composed of multiple sensor nodes, a sink node, a gateway, and a server. Each of the sensor nodes is equipped with a 3-axis AMR sensor and deployed in the center of a parking space. The sensor node reads its sensor values periodically and transmits the data to the sink node if the current and immediate past sensor values show a difference exceeding a threshold value. The operations of the sink and sensor nodes are described in detail along with flow diagrams. The protocol allows a low-duty cycle operation of the sensor nodes and a flexible adjustment of the threshold value used by the sensor nodes.

Keywords: car parking monitoring, sensor node, wireless sensor network, network protocol

Procedia PDF Downloads 497
6042 Views and Experiences of Medical Students of Kerman University of Medical Sciences on Facilitators and Inhibitators of Quality of Education in the Clinical Education System in 2021

Authors: Hossein Ghaedamini, Salman Farahbakhsh, Alireza Amirbeigi, Zahra Saghafi, Salman Daneshi, Alireza Ghaedamini

Abstract:

Background: Assessing the challenges of clinical education of medical students is one of the most important and sensitive parts of medical education. The aim of this study was to investigate the views and experiences of Kerman medical students on the factors that facilitate and inhibit the quality of clinical education. Materials and Methods: This research was qualitative and used a phenomenological approach. The study population included medical interns of Kerman University of Medical Sciences in 1400. The method of data collection was in-depth interviews with participants. Data were encoded and analyzed by Claizey stepwise model. Results: First, about 540 primary codes were extracted in the form of two main themes (facilitators and inhibitors) and 10 sub-themes including providing motivational models and creating interest in interns, high scientific level of professors and the appropriate quality of their teaching, the use of technology in the clinical education process, delegating authority and freedom of action and more responsibilities to interns, inappropriate treatment of some officials, professors, assistants and department staff with their interns, inadequate educational programming, lack of necessary cooperation and providing inappropriate treatment by clinical training experts for interns, inadequate evaluation method in clinical training for interns, poor quality mornings, the unefficiency of grand rounds, the inappropriate way of evaluating clinical training for interns, the lack of suitable facilities and conditions with the position of a medical intern, and the hardwork of some departments were categorized. Conclusion: Clinical education is always mixed with special principles and subtleties, and special attention to facilitators and inhibitors in this process has an important role in improving its quality.

Keywords: clinical education, medical students, qualitative study, education

Procedia PDF Downloads 45
6041 The Effects of Physician-Family Communication from the Point View of Clinical Staff

Authors: Lu-Chiu Huang, Pei-Pei Chen, Li-Chin Yu, Chiao-Wen Kuo, Tsui-Tao Liu, Rung-Chuang Feng

Abstract:

Purpose: People put increasing emphasis on demands of medical quality and protecting their interests. Patients' or family's dissatisfaction with medical care may easily lead to medical dispute. Physician-family communication plays an essential role in medical care. A sound communication cannot only strengthen patients' belief in the medical team but make patient have definite insight into treatment course of the disease. A family meeting provides an effective platform for communication between clinical staff, patients and family. Decisions and consensuses formed in family meetings can promote patients' or family's satisfaction with medical care. Clinical staff's attitudes toward family meeting may determine behavioral intentions to hold family meeting. This study aims to explore clinical staff's difficulties in holding family meeting and evaluate how their attitudes and behavior influence the effect of family meetings. Methods: This was a cross-sectional study. It was conducted at a regional teaching hospital in Taipei city. The research team developed its own structural questionnaires, whose expert validity was checked by the nursing experts. Participants filled in the questionnaires online. Data were collected by convenience sampling. A total of 568 participants were invited. They included doctors, nurses, social workers, and so on. Results: 1) The average score of ‘clinical staff’s attitudes to family meetings’ was 5.15 (SD=0.898). It fell between ‘somewhat agree’ and ‘mostly agree’ on the 7-point likert scale. It indicated that clinical staff had positive attitudes toward family meetings, 2) The average score of ‘clinical staff’s behavior to family meetings’ was 5.61 (SD=0.937). It fell between ‘somewhat agree’ and ‘mostly agree’ on the 7-point likert scale. It meant clinical staff tended to have positive behavior at the family meeting, and 3) The average score of ‘Difficulty in conducting family meetings’ was 5.15 (SD=0.897). It fell between ‘somewhat agree’ and ‘mostly agree’ on the 7-point likert scale. The higher the score was, the less difficulty the clinical staff felt. It demonstrated clinical staff felt less difficulty in conducting family meetings. Clinical staff's identification with family meetings brought favored effects. Persistent and active promotion for family meetings can bring patients and family more benefits. Implications for practice: Understanding clinical staff's difficulty in participating family meeting and exploring their attitudes or behavior toward physician-family communication are helpful to develop modes of interaction. Consequently, quality and satisfaction of physician-family communication can be increased.

Keywords: clinical staff, communication, family meeting, physician-family

Procedia PDF Downloads 308
6040 Effects of Clinical Practice Guideline on Knowledge and Preventive Practices of Nursing Personnel and Incidences of Ventilator-associated Pneumonia Thailand

Authors: Phawida Wattanasoonthorn

Abstract:

Ventilator-associated pneumonia is a serious infection found to be among the top three infections in the hospital. To investigate the effects of clinical practice guideline on knowledge and preventive practices of nursing personnel, and incidences of ventilator-associated pneumonia. A pre-post quasi-experimental study on 17 professional nurses, and 123 ventilator-associated pneumonia patients admitted to the surgical intensive care unit, and the accident and surgical ward of Songkhla Hospital from October 2013 to January 2014. The study found that after using the clinical practice guideline, the subjects’ median score increased from 16.00 to 19.00. The increase in practicing correctly was from 66.01 percent to 79.03 percent with the statistical significance level of .05, and the incidences of ventilator-associated pneumonia decreased by 5.00 percent. The results of this study revealed that the use of the clinical practice guideline helped increase knowledge and practice skill of nursing personnel, and decrease incidences of ventilator-associated pneumonia. Thus, nursing personnel should be encouraged, reminded and promoted to continue using the practice guideline through various means including training, providing knowledge, giving feedback, and putting up posters to remind them of practicing correctly and sustainably.

Keywords: Clinical Practice Guideline, knowledge, Preventive Ventilator, Pneumonia

Procedia PDF Downloads 372
6039 Effectiveness, Safety, and Tolerability Profile of Stribild® in HIV-1-infected Patients in the Clinical Setting

Authors: Heiko Jessen, Laura Tanus, Slobodan Ruzicic

Abstract:

Objectives: The efficacy of Stribild®, an integrase strand transfer inhibitor (INSTI) -based STR, has been evaluated in randomized clinical trials and it has demonstrated durable capability in terms of achieving sustained suppression of HIV-1 RNA-levels. However, differences in monitoring frequency, existing selection bias and profile of patients enrolled in the trials, may all result in divergent efficacy of this regimen in routine clinical settings. The aim of this study was to assess the virologic outcomes, safety and tolerability profile of Stribild® in a routine clinical setting. Methods: This was a retrospective monocentric analysis on HIV-1-infected patients, who started with or were switched to Stribild®. Virological failure (VF) was defined as confirmed HIV-RNA>50 copies/ml. The minimum time of follow-up was 24 weeks. The percentage of patients remaining free of therapeutic failure was estimated using the time-to-loss-of-virologic-response (TLOVR) algorithm, by intent-to-treat analysis. Results: We analyzed the data of 197 patients (56 ART-naïve and 141 treatment-experienced patients), who fulfilled the inclusion criteria. Majority (95.9%) of patients were male. The median time of HIV-infection at baseline was 2 months in treatment-naïve and 70 months in treatment-experienced patients. Median time [IQR] under ART in treatment-experienced patients was 37 months. Among the treatment-experienced patients 27.0% had already been treated with a regimen consisting of two NRTIs and one INSTI, whereas 18.4% of them experienced a VF. The median time [IQR] of virological suppression prior to therapy with Stribild® in the treatment-experienced patients was 10 months [0-27]. At the end of follow-up (median 33 months), 87.3% (95% CI, 83.5-91.2) of treatment-naïve and 80.3% (95% CI, 75.8-84.8) of treatment-experienced patients remained free of therapeutic failure. Considering only treatment-experienced patients with baseline VL<50 copies/ml, 83.0% (95% CI, 78.5-87.5) remained free of therapeutic failure. A total of 17 patients stopped treatment with Stribild®, 5.4% (3/56) of them were treatment-naïve and 9.9% (14/141) were treatment-experienced patients. The Stribild® therapy was discontinued in 2 (1.0%) because of VF, loss to follow-up in 4 (2.0%), and drug-drug interactions in 2 (1.0%) patients. Adverse events were in 7 (3.6%) patients the reason to switch from therapy with Stribild® and further 2 (1.0%) patients decided personally to switch. The most frequently observed adverse events were gastrointestinal side effects (20.0%), headache (8%), rash events (7%) and dizziness (6%). In two patients we observed an emergence of novel resistances in integrase-gene. The N155H evolved in one patient and resulted in VF. In another patient S119R evolved either during or shortly upon switch from therapy with Stribild®. In one further patient with VF two novel mutations in the RT-gene were observed when compared to historical genotypic test result (V106I/M and M184V), whereby it is not clear whether they evolved during or already before the switch to Stribild®. Conclusions: Effectiveness of Stribild® for treatment-naïve patients was consistent with data obtained in clinical trials. The safety and tolerability profile as well as resistance development confirmed clinical efficacy of Stribild® in a daily practice setting.

Keywords: ART, HIV, integrase inhibitor, stribild

Procedia PDF Downloads 260
6038 Perceived Barriers and Benefits of Technology-Based Progress Monitoring for Non-Academic Individual Education Program Goals

Authors: A. Drelick, T. Sondergeld, M. Decarlo-Tecce, K. McGinley

Abstract:

In 1975, a free, appropriate public education (FAPE) was granted for all students in the United States regardless of their disabilities. As a result, the special education landscape has been reshaped through new policies and legislation. Progress monitoring, a specific component of an Individual Education Program (IEP) calls, for the use of data collection to determine the appropriateness of services provided to students with disabilities. The recent US Supreme Court ruling in Endrew F. v. Douglas County warrants giving increased attention to student progress, specifically pertaining to improving functional, or non-academic, skills that are addressed outside the general education curriculum. While using technology to enhance data collection has become a common practice for measuring academic growth, its application for non-academic IEP goals is uncertain. A mixed-methods study examined current practices and rationales for implementing technology-based progress monitoring focused on non-academic IEP goals. Fifty-seven participants responded to an online survey regarding their progress monitoring programs for non-academic goals. After isolated analysis and interpretation of quantitative and qualitative results, data were synthesized to produce meta-inferences that drew broader conclusions on the topic. For the purpose of this paper, specific focus will be placed on the perceived barriers and benefits of implementing technology-based progress monitoring protocols for non-academic IEP goals. The findings of this study highlight facts impacting the use of technology-based progress monitoring. Perceived barriers to implementation include: (1) lack of training, (2) access to technology, (3) outdated or inoperable technology, (4) reluctance to change, (5) cost, (6) lack of individualization within technology-based programs, and (7) legal issues in special education; while perceived benefits include: (1) overall ease of use, (2) accessibility, (3) organization, (4) potential for improved presentation of data, (5) streamlining the progress-monitoring process, and (6) legal issues in special education. Based on these conclusions, recommendations are made to IEP teams, school districts, and software developers to improve the progress-monitoring process for functional skills.

Keywords: special education, progress monitoring, functional skills, technology

Procedia PDF Downloads 215
6037 Conception of a Predictive Maintenance System for Forest Harvesters from Multiple Data Sources

Authors: Lazlo Fauth, Andreas Ligocki

Abstract:

For cost-effective use of harvesters, expensive repairs and unplanned downtimes must be reduced as far as possible. The predictive detection of failing systems and the calculation of intelligent service intervals, necessary to avoid these factors, require in-depth knowledge of the machines' behavior. Such know-how needs permanent monitoring of the machine state from different technical perspectives. In this paper, three approaches will be presented as they are currently pursued in the publicly funded project PreForst at Ostfalia University of Applied Sciences. These include the intelligent linking of workshop and service data, sensors on the harvester, and a special online hydraulic oil condition monitoring system. Furthermore the paper shows potentials as well as challenges for the use of these data in the conception of a predictive maintenance system.

Keywords: predictive maintenance, condition monitoring, forest harvesting, forest engineering, oil data, hydraulic data

Procedia PDF Downloads 107
6036 Community-Based Reference Interval of Selected Clinical Chemistry Parameters Among Apparently Healthy Adolescents in Mekelle City, Tigrai, Northern Ethiopia

Authors: Getachew Belay Kassahun

Abstract:

Background: Locally established clinical laboratory reference intervals (RIs) are required to interpret laboratory test results for screening, diagnosis, and prognosis. The objective of this study was to establish a reference interval of clinical chemistry parameters among apparently healthy adolescents aged between 12 and 17 years in Mekelle, Tigrai, in the northern part of Ethiopia. Methods: Community-based cross-sectional study was employed from December 2018 to March 2019 in Mekelle City among 172 males and 172 females based on a Multi-stage sampling technique. Blood samples were tested for Fasting blood sugar (FBS), alanine amino transferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), Creatinine, urea, total protein, albumin (ALB), direct and indirect bilirubin (BIL.D and BIL.T) using 25 Bio system clinical chemistry analyzer. Results were analyzed using SPSS version 23 software and based on the Clinical Laboratory Standard Institute (CLSI)/ International Federation of Clinical Chemistry (IFCC) C 28-A3 Guideline which defines the reference interval as the 95% central range of 2.5th and 97.5th percentiles. Mann Whitney U test, descriptive statistics and box and whisker were statistical tools used for analysis. Results: This study observed statistically significant differences between males and females in ALP, ALT, AST, Urea and Creatinine Reference intervals. The established reference intervals for males and females, respectively, were: ALP (U/L) 79.48-492.12 versus 63.56-253.34, ALT (U/L) 4.54-23.69 versus 5.1-20.03, AST 15.7- 39.1 versus 13.3- 28.5, Urea (mg/dL) 9.33-24.99 versus 7.43-23.11, and Creatinine (mg/dL) 0.393-0.957 versus 0.301-0.846. The combined RIs for Total Protein (g/dL) were 6.08-7.85, ALB (g/dL) 4.42-5.46, FBS(mg/dL) 65-110, BIL.D (mg/dL) 0.033-0.532, and BIL.T (mg/dL) 0.106-0.812. Conclusions: The result showed a marked difference between sex and company-derived values for selected clinical chemistry parameters. Thus, the use of age and sex-specific locally established reference intervals for clinical chemistry parameters is recommended.

Keywords: reference interval, adolescent, clinical chemistry, Ethiopia

Procedia PDF Downloads 47
6035 Structural Health Monitoring of Buildings and Infrastructure

Authors: Mojtaba Valinejadshoubi, Ashutosh Bagchi, Osama Moselhi

Abstract:

Structures such as buildings, bridges, dams, wind turbines etc. need to be maintained against various factors such as deterioration, excessive loads, environment, temperature, etc. Choosing an appropriate monitoring system is important for determining any critical damage to a structure and address that to avoid any adverse consequence. Structural Health Monitoring (SHM) has emerged as an effective technique to monitor the health of the structures. SHM refers to an ongoing structural performance assessment using different kinds of sensors attached to or embedded in the structures to evaluate their integrity and safety to help engineers decide on rehabilitation measures. Ability of SHM in identifying the location and severity of structural damages by considering any changes in characteristics of the structures such as their frequency, stiffness and mode shapes helps engineers to monitor the structures and take the most effective corrective actions to maintain their safety and extend their service life. The main objective of this study is to review the overall SHM process specifically determining the natural frequency of an instrumented simply-supported concrete beam using modal testing and finite element model updating.

Keywords: structural health monitoring, natural frequency, modal analysis, finite element model updating

Procedia PDF Downloads 314
6034 Designing of Induction Motor Efficiency Monitoring System

Authors: Ali Mamizadeh, Ires Iskender, Saeid Aghaei

Abstract:

Energy is one of the important issues with high priority property in the world. Energy demand is rapidly increasing depending on the growing population and industry. The useable energy sources in the world will be insufficient to meet the need for energy. Therefore, the efficient and economical usage of energy sources is getting more importance. In a survey conducted among electric consuming machines, the electrical machines are consuming about 40% of the total electrical energy consumed by electrical devices and 96% of this consumption belongs to induction motors. Induction motors are the workhorses of industry and have very large application areas in industry and urban systems like water pumping and distribution systems, steel and paper industries and etc. Monitoring and the control of the motors have an important effect on the operating performance of the motor, driver selection and replacement strategy management of electrical machines. The sensorless monitoring system for monitoring and calculating efficiency of induction motors are studied in this study. The equivalent circuit of IEEE is used in the design of this study. The terminal current and voltage of induction motor are used in this motor to measure the efficiency of induction motor. The motor nameplate information and the measured current and voltage are used in this system to calculate accurately the losses of induction motor to calculate its input and output power. The efficiency of the induction motor is monitored online in the proposed method without disconnecting the motor from the driver and without adding any additional connection at the motor terminal box. The proposed monitoring system measure accurately the efficiency by including all losses without using torque meter and speed sensor. The monitoring system uses embedded architecture and does not need to connect to a computer to measure and log measured data. The conclusion regarding the efficiency, the accuracy and technical and economical benefits of the proposed method are presented. The experimental verification has been obtained on a 3 phase 1.1 kW, 2-pole induction motor. The proposed method can be used for optimal control of induction motors, efficiency monitoring and motor replacement strategy.

Keywords: induction motor, efficiency, power losses, monitoring, embedded design

Procedia PDF Downloads 322
6033 Integrating Wearable-Textiles Sensors and IoT for Continuous Electromyography Monitoring

Authors: Bulcha Belay Etana, Benny Malengier, Debelo Oljira, Janarthanan Krishnamoorthy, Lieva Vanlangenhove

Abstract:

Electromyography (EMG) is a technique used to measure the electrical activity of muscles. EMG can be used to assess muscle function in a variety of settings, including clinical, research, and sports medicine. The aim of this study was to develop a wearable textile sensor for EMG monitoring. The sensor was designed to be soft, stretchable, and washable, making it suitable for long-term use. The sensor was fabricated using a conductive thread material that was embroidered onto a fabric substrate. The sensor was then connected to a microcontroller unit (MCU) and a Wi-Fi-enabled module. The MCU was programmed to acquire the EMG signal and transmit it wirelessly to the Wi-Fi-enabled module. The Wi-Fi-enabled module then sent the signal to a server, where it could be accessed by a computer or smartphone. The sensor was able to successfully acquire and transmit EMG signals from a variety of muscles. The signal quality was comparable to that of commercial EMG sensors. The development of this sensor has the potential to improve the way EMG is used in a variety of settings. The sensor is soft, stretchable, and washable, making it suitable for long-term use. This makes it ideal for use in clinical settings, where patients may need to wear the sensor for extended periods of time. The sensor is also small and lightweight, making it ideal for use in sports medicine and research settings. The data for this study was collected from a group of healthy volunteers. The volunteers were asked to perform a series of muscle contractions while the EMG signal was recorded. The data was then analyzed to assess the performance of the sensor. The EMG signals were analyzed using a variety of methods, including time-domain analysis and frequency-domain analysis. The time-domain analysis was used to extract features such as the root mean square (RMS) and average rectified value (ARV). The frequency-domain analysis was used to extract features such as the power spectrum. The question addressed by this study was whether a wearable textile sensor could be developed that is soft, stretchable, and washable and that can successfully acquire and transmit EMG signals. The results of this study demonstrate that a wearable textile sensor can be developed that meets the requirements of being soft, stretchable, washable, and capable of acquiring and transmitting EMG signals. This sensor has the potential to improve the way EMG is used in a variety of settings.

Keywords: EMG, electrode position, smart wearable, textile sensor, IoT, IoT-integrated textile sensor

Procedia PDF Downloads 45
6032 The Art and Science of Trauma-Informed Psychotherapy: Guidelines for Inter-Disciplinary Clinicians

Authors: Daphne Alroy-Thiberge

Abstract:

Trauma-impacted individuals present unique treatment challenges that include high reactivity, hyper-and hypo-arousal, poor adherence to therapy, as well as powerful transference and counter-transference experiences in therapy. This work provides an overview of the clinical tenets most often encountered in trauma-impacted individuals. Further, it provides readily applicable clinical techniques to optimize therapeutic rapport and facilitate accelerated positive mental health outcomes. Finally, integrated neuroscience and clinical evidence-based data are discussed to shed new light on crisis states in trauma-impacted individuals. This knowledge is utilized to provide effective and concrete interventions towards rapid and successful de-escalation of the impacted individual. A highly interactive, adult-learning-principles-based modality is utilized to provide an organic learning experience for participants. The information and techniques learned aim to increase clinical effectiveness, reduce staff injuries and burnout, and significantly enhance positive mental health outcomes and self-determination for the trauma-impacted individuals treated.

Keywords: clinical competencies, crisis interventions, psychotherapy techniques, trauma informed care

Procedia PDF Downloads 63
6031 The Clinical Manifestations of Myocardial Bridging in Patients with Coronary Artery Disease

Authors: Alexey Yu. Martynov, Sulejman Bayramov

Abstract:

Introduction: The myocardial bridging is the most common anomaly of the coronary arteries (CA). Depending on the examination method, the frequency of detected myocardial bridges (MB) varies in a rather wide range. The typical clinical manifestations of MB are angina pectoris, arrhythmias, sudden cardiac death. Objective: To study the incidence of MB in patients hospitalized with coronary artery disease (CAD). To assess clinical manifestations of MB in patients admitted with CAD. Materials and methods: A retrospective analysis of 19159 case histories of patients admitted at clinical city hospital in Moscow from 01.01.2018 to 31.12 2019 with CAD was performed. 9384 patients’ coronary angiographies (CAG) were examined for MB. The localization of MB, the degree of coronary contraction by MB, the number of MB, isolated MB and combined with CAD were assessed. The clinical manifestations of MB were determined. Results: MB was detected in 52 patients all with one myocardial bridge. 20 patients with MB have intact CA, and 32 patients have MB combined with CAD. Among 20 patients with intact CA: I degree of MB contraction (up to 50%) was detected in 9 patients. Clinical manifestations in five cases were angina pectoris, in 3 myocardial infarction (MI) - 1 patients with ST segment elevation MI (STEMI), 2 without ST segment elevation MI (NSTEMI), 1 post-infarction cardiosclerosis (PICS). Stable angina II FC in 3, III FC in 1, vasospastic angina (VSA) in 1 patient. II degree of MB contraction (up to 50-70%) was determined in 9 patients: in seven cases angina pectoris was detected, 1 NSTEMI, 1 PICS. Stable angina II FC in 3, III FC in 1, VSA in 3 patients. III degree of MB contraction (> 70%) detected in 2 patients. II FC stable angina in one case, PICS in another. Among 32 patients having MB combined with CAD I degree of MB contraction was observed in 20 patients. Clinical manifestations in 12 cases were angina pectoris in 8 II FC and in 4 III FC, 7 MI 6 with STEMI and 1 NSTEMI, 1 PICS. II degree of MB contraction was detected in 7 patients, 4 of them had angina pectoris, 3 MI 2 with STEMI and 1 NSTEMI. Stable angina II FC in 3, VSA in 1 patients. III degree of MB contraction was diagnosed in five patients. In two cases, II FC and III FC stable angina were observed, 2 MI with STEMI and NSTEMI, 1 PICS. Conclusions: MB incidence is one in 368 patients with CAD. The most common involvement (68%) is MB combined with CA atherosclerotic lesions. MB with intact CA are detected in one-third (32%) of patients. The first-degree MB contraction is most frequent condition. MI is more often detected in intact CA with first degree MB than in the second degree. The degree of MB contraction was not correlated with the severity of the clinical manifestations.

Keywords: clinical manifestations, coronary angiography, coronary artery disease, myocardial bridging, myocardial infarction, stable angina

Procedia PDF Downloads 99
6030 Improving Functionality of Radiotherapy Department Through: Systemic Periodic Clinical Audits

Authors: Kamal Kaushik, Trisha, Dandapni, Sambit Nanda, A. Mukherjee, S. Pradhan

Abstract:

INTRODUCTION: As complexity in radiotherapy practice and processes are increasing, there is a need to assure quality control to a greater extent. At present, no international literature available with regards to the optimal quality control indicators for radiotherapy; moreover, few clinical audits have been conducted in the field of radiotherapy. The primary aim is to improve the processes that directly impact clinical outcomes for patients in terms of patient safety and quality of care. PROCEDURE: A team of an Oncologist, a Medical Physicist and a Radiation Therapist was formed for weekly clinical audits of patient’s undergoing radiotherapy audits The stages for audits include Pre planning audits, Simulation, Planning, Daily QA, Implementation and Execution (with image guidance). Errors in all the parts of the chain were evaluated and recorded for the development of further departmental protocols for radiotherapy. EVALUATION: The errors at various stages of radiotherapy chain were evaluated and recorded for comparison before starting the clinical audits in the department of radiotherapy and after starting the audits. It was also evaluated to find the stage in which maximum errors were recorded. The clinical audits were used to structure standard protocols (in the form of checklist) in department of Radiotherapy, which may lead to further reduce the occurrences of clinical errors in the chain of radiotherapy. RESULTS: The aim of this study is to perform a comparison between number of errors in different part of RT chain in two groups (A- Before Audit and B-After Audit). Group A: 94 pts. (48 males,46 female), Total no. of errors in RT chain:19 (9 needed Resimulation) Group B: 94 pts. (61 males,33 females), Total no. of errors in RT chain: 8 (4 needed Resimulation) CONCLUSION: After systematic periodic clinical audits percentage of error in radiotherapy process reduced more than 50% within 2 months. There is a great need in improving quality control in radiotherapy, and the role of clinical audits can only grow. Although clinical audits are time-consuming and complex undertakings, the potential benefits in terms of identifying and rectifying errors in quality control procedures are potentially enormous. Radiotherapy being a chain of various process. There is always a probability of occurrence of error in any part of the chain which may further propagate in the chain till execution of treatment. Structuring departmental protocols and policies helps in reducing, if not completely eradicating occurrence of such incidents.

Keywords: audit, clinical, radiotherapy, improving functionality

Procedia PDF Downloads 48
6029 Intelligent Tooling Embedded Sensors for Monitoring the Wear of Cutting Tools in Turning Applications

Authors: Hatim Laalej, Jon Stammers

Abstract:

In machining, monitoring of tool wear is essential for achieving the desired dimensional accuracy and surface finish of a machined workpiece. Currently, the task of monitoring the wear on the cutting tool is carried out by the operator who performs manual inspections of the cutting tool, causing undesirable stoppages of machine tools and consequently resulting in costs incurred from loss of productivity. The cutting tool consumable costs may also be higher than necessary when tools are changed before the end of their useful life. Furthermore, damage can be caused to the workpiece when tools are not changed soon enough leading to a significant increase in the costs of manufacturing. The present study is concerned with the development of break sensor printed on the flank surface of poly-crystalline diamond (PCD) cutting to perform on-line condition monitoring of the cutting tool used to machine Titanium Ti-6al-4v bar. The results clearly show that there is a strong correlation between the break sensor measurements and the amount of wear in the cutting tool. These findings are significant in that they help the user/operator of the machine tool to determine the condition of the cutting tool without the need of performing manual inspection, thereby reducing the manufacturing costs such as the machine down time.

Keywords: machining, manufacturing, tool wear, signal processing

Procedia PDF Downloads 203
6028 A Digital Filter for Symmetrical Components Identification

Authors: Khaled M. El-Naggar

Abstract:

This paper presents a fast and efficient technique for monitoring and supervising power system disturbances generated due to dynamic performance of power systems or faults. Monitoring power system quantities involve monitoring fundamental voltage, current magnitudes, and their frequencies as well as their negative and zero sequence components under different operating conditions. The proposed technique is based on simulated annealing optimization technique (SA). The method uses digital set of measurements for the voltage or current waveforms at power system bus to perform the estimation process digitally. The algorithm is tested using different simulated data to monitor the symmetrical components of power system waveforms. Different study cases are considered in this work. Effects of number of samples, sampling frequency and the sample window size are studied. Results are reported and discussed.

Keywords: estimation, faults, measurement, symmetrical components

Procedia PDF Downloads 437
6027 Photoplethysmography-Based Device Designing for Cardiovascular System Diagnostics

Authors: S. Botman, D. Borchevkin, V. Petrov, E. Bogdanov, M. Patrushev, N. Shusharina

Abstract:

In this paper, we report the development of the device for diagnostics of cardiovascular system state and associated automated workstation for large-scale medical measurement data collection and analysis. It was shown that optimal design for the monitoring device is wristband as it represents engineering trade-off between accuracy and usability. The monitoring device is based on the infrared reflective photoplethysmographic sensor, which allows collecting multiple physiological parameters, such as heart rate and pulsing wave characteristics. Developed device use BLE interface for medical and supplementary data transmission to the coupled mobile phone, which process it and send it to the doctor's automated workstation. Results of this experimental model approbation confirmed the applicability of the proposed approach.

Keywords: cardiovascular diseases, health monitoring systems, photoplethysmography, pulse wave, remote diagnostics

Procedia PDF Downloads 473