Search results for: bone drilling
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1061

Search results for: bone drilling

1001 Reconstructing Calvarial Bone Lesions Using PHBV Scaffolds and Cord Blood Mesenchymal Stem Cells in Rat

Authors: Hamed Hosseinkazemi, Esmaeil Biazar

Abstract:

For tissue engineering of bone, anatomical and operational reconstructions of damaged tissue seem to be vital. This is done via reconstruction of bone and appropriate biological joint with bone tissues of damaged areas. In this study the condition of biodegradable bed Nanofibrous PHBV and USSC cells were used to accelerate bone repair of damaged area. Hollow nanofabrication scaffold of damageable life was designed as PHBV by electrospinning and via determining the best factors such as the kind and amount of solvent, specific volume and rate. The separation of osseous tissue infiltration and evaluating its nature by flow cytometrocical analysis was done. Animal test including USSC as well as PHBV condition in the damaged bone was done in the rat. After 8 weeks the implanted area was analyzed using CT scan and was sent to histopathology ward. Finally, the rate and quality of reconstruction were determined after H and E coloring. Histomorphic analysis indicated a statistically significant difference between the experimental group of PHBV, USSC+PHBV and control group. Besides, the histopathologic analysis showed that bone reconstruction rate was high in the area containing USSC and PHBV, compared with area having PHBV and control group and consequently the reconstruction quality of bones and the relationship between the new bone tissues and surrounding bone tissues were high too. Using PHBR scaffold and USSC together could be useful in the amending of wide range of bone lesion.

Keywords: bone lesion, nanofibrous PHBV, stem cells, umbilical cord blood

Procedia PDF Downloads 290
1000 Prediction of Cutting Tool Life in Drilling of Reinforced Aluminum Alloy Composite Using a Fuzzy Method

Authors: Mohammed T. Hayajneh

Abstract:

Machining of Metal Matrix Composites (MMCs) is very significant process and has been a main problem that draws many researchers to investigate the characteristics of MMCs during different machining process. The poor machining properties of hard particles reinforced MMCs make drilling process a rather interesting task. Unlike drilling of conventional materials, many problems can be seriously encountered during drilling of MMCs, such as tool wear and cutting forces. Cutting tool wear is a very significant concern in industries. Cutting tool wear not only influences the quality of the drilled hole, but also affects the cutting tool life. Prediction the cutting tool life during drilling is essential for optimizing the cutting conditions. However, the relationship between tool life and cutting conditions, tool geometrical factors and workpiece material properties has not yet been established by any machining theory. In this research work, fuzzy subtractive clustering system has been used to model the cutting tool life in drilling of Al2O3 particle reinforced aluminum alloy composite to investigate of the effect of cutting conditions on cutting tool life. This investigation can help in controlling and optimizing of cutting conditions when the process parameters are adjusted. The built model for prediction the tool life is identified by using drill diameter, cutting speed, and cutting feed rate as input data. The validity of the model was confirmed by the examinations under various cutting conditions. Experimental results have shown the efficiency of the model to predict cutting tool life.

Keywords: composite, fuzzy, tool life, wear

Procedia PDF Downloads 264
999 Stress-Strain Relation for Human Trabecular Bone Based on Nanoindentation Measurements

Authors: Marek Pawlikowski, Krzysztof Jankowski, Konstanty Skalski, Anna Makuch

Abstract:

Nanoindentation or depth-sensing indentation (DSI) technique has proven to be very useful to measure mechanical properties of various tissues at a micro-scale. Bone tissue, both trabecular and cortical one, is one of the most commonly tested tissues by means of DSI. Most often such tests on bone samples are carried out to compare the mechanical properties of lamellar and interlamellar bone, osteonal bone as well as compact and cancellous bone. In the paper, a relation between stress and strain for human trabecular bone is presented. The relation is based on the results of nanoindentation tests. The formulation of a constitutive model for human trabecular bone is based on nanoindentation tests. In the study, the approach proposed by Olivier-Pharr is adapted. The tests were carried out on samples of trabecular tissue extracted from human femoral heads. The heads were harvested during surgeries of artificial hip joint implantation. Before samples preparation, the heads were kept in 95% alcohol in temperature 4 Celsius degrees. The cubic samples cut out of the heads were stored in the same conditions. The dimensions of the specimens were 25 mm x 25 mm x 20 mm. The number of 20 samples have been tested. The age range of donors was between 56 and 83 years old. The tests were conducted with the indenter spherical tip of the diameter 0.200 mm. The maximum load was P = 500 mN and the loading rate 500 mN/min. The data obtained from the DSI tests allows one only to determine bone behoviour in terms of nanoindentation force vs. nanoindentation depth. However, it is more interesting and useful to know the characteristics of trabecular bone in the stress-strain domain. This allows one to simulate trabecular bone behaviour in a more realistic way. The stress-strain curves obtained in the study show relation between the age and the mechanical behaviour of trabecular bone. It was also observed that the bone matrix of trabecular tissue indicates an ability of energy absorption.

Keywords: constitutive model, mechanical behaviour, nanoindentation, trabecular bone

Procedia PDF Downloads 186
998 Benign Osteoblastoma of the Mandible Resection and Replacement of the Defects with Decellularized Cattle Bone Scaffold with Mesenchymal Bone Marrow Stem Cells

Authors: K. Mardaleishvili, G. Loladze, G. Shatirishivili, D. Chakhunashvili, A. Vishnevskaya, Z. Kakabadze

Abstract:

Benign osteoblastoma is a benign tumor of the bone, usually affecting the vertebrae and long tubular bones. It is a rarely seen tumor of the facial bones. The authors present a case of a 28-year-old male patient with a tumor in mandibular body. The lesion was radically resected and histological analysis of the specimen demonstrated features typical of a benign osteoblastoma. The defect of the jaw was reconstructed with titanium implants and decellularized and lyophilized cattle bone matrix with mesenchymal bone marrow stem cells transplantation. This presentation describes the procedures for rehabilitating a patient with decellularized bone scaffold in the region of the face, recovering the facial contours and esthetics of the patient.

Keywords: facial bones, osteoblastoma, stem cells, transplantation

Procedia PDF Downloads 398
997 Minimizing the Drilling-Induced Damage in Fiber Reinforced Polymeric Composites

Authors: S. D. El Wakil, M. Pladsen

Abstract:

Fiber reinforced polymeric (FRP) composites are finding wide-spread industrial applications because of their exceptionally high specific strength and specific modulus of elasticity. Nevertheless, it is very seldom to get ready-for-use components or products made of FRP composites. Secondary processing by machining, particularly drilling, is almost always required to make holes for fastening components together to produce assemblies. That creates problems since the FRP composites are neither homogeneous nor isotropic. Some of the problems that are encountered include the subsequent damage in the region around the drilled hole and the drilling – induced delamination of the layer of ply, that occurs both at the entrance and the exit planes of the work piece. Evidently, the functionality of the work piece would be detrimentally affected. The current work was carried out with the aim of eliminating or at least minimizing the work piece damage associated with drilling of FPR composites. Each test specimen involves a woven reinforced graphite fiber/epoxy composite having a thickness of 12.5 mm (0.5 inch). A large number of test specimens were subjected to drilling operations with different combinations of feed rates and cutting speeds. The drilling induced damage was taken as the absolute value of the difference between the drilled hole diameter and the nominal one taken as a percentage of the nominal diameter. The later was determined for each combination of feed rate and cutting speed, and a matrix comprising those values was established, where the columns indicate varying feed rate while and rows indicate varying cutting speeds. Next, the analysis of variance (ANOVA) approach was employed using Minitab software, in order to obtain the combination that would improve the drilling induced damage. Experimental results show that low feed rates coupled with low cutting speeds yielded the best results.

Keywords: drilling of composites, dimensional accuracy of holes drilled in composites, delamination and charring, graphite-epoxy composites

Procedia PDF Downloads 366
996 Suitability Verification of Cellulose Nanowhisker as a Scaffold for Bone Tissue Engineering

Authors: Moon Hee Jung, Dae Seung Kim, Sang-Myung Jung, Gwang Heum Yoon, Hoo Cheol Lee, Hwa Sung Shin

Abstract:

Scaffolds are an important part to support growth and differentiation of osteoblast for regeneration of injured bone in bone tissue engineering. We utilized tunicate cellulose nanowhisker (CNW) as scaffold and developed complex system that can enhance differentiation of osteoblast by applying mechanical stimulation. CNW, a crystal form of cellulose, has high stiffness with a large surface area and is useful as a biomedical material due to its biodegradability and biocompatibility. In this study, CNW was obtained from tunicate extraction and was confirmed for its adhesion, differentiation, growth of osteoblast without cytotoxicity. In addition, osteoblast was successfully differentiated under mechanical stimulation, followed by calcium dependent signaling. In conclusion, we verified suitability of CNW as scaffold and possibility of bone substitutes.

Keywords: osteoblast, cellulose nanowhisker, CNW, mechanical stimulation, bone tissue engineering, bone substitute

Procedia PDF Downloads 336
995 Influence of Modified and Unmodified Cow Bone on the Mechanical Properties of Reinforced Polyester Composites for Biomedical Applications

Authors: I. O. Oladele, J. A. Omotoyinbo, A. M. Okoro, A. G. Okikiola, J. L. Olajide

Abstract:

This work was carried out to investigate comparatively the effects of modified and unmodified cow bone particles on the mechanical properties of polyester matrix composites in order to investigate the suitability of the materials as biomaterial. Cow bones were procured from an abattoir, sun dried for 4 weeks and crushed. The crushed bones were divided into two, where one part was turned to ash while the other part was pulverized with laboratory ball mill before the two grades were sieved using 75 µm sieve size. Bone ash and bone particle reinforced tensile and flexural composite samples were developed from pre-determined proportions of 2, 4, 6, and 8 %. The samples after curing were stripped from the moulds and were allowed to further cure for 3 weeks before tensile and flexural tests were performed on them. The tensile test result showed that, 8 wt % bone particle reinforced polyester composites has higher tensile properties except for modulus of elasticity where 8 wt % bone ash particle reinforced composites has higher value while for flexural test, bone ash particle reinforced composites demonstrate the best flexural properties. The results show that these materials are structurally compatible.

Keywords: biomedical, composites, cow bone, mechanical properties, polyester, reinforcement

Procedia PDF Downloads 250
994 Inverse Mode Shape Problem of Hand-Arm Vibration (Humerus Bone) for Bio-Dynamic Response Using Varying Boundary Conditions

Authors: Ajay R, Rammohan B, Sridhar K S S, Gurusharan N

Abstract:

The objective of the work is to develop a numerical method to solve the inverse mode shape problem by determining the cross-sectional area of a structure for the desired mode shape via the vibration response study of the humerus bone, which is in the form of a cantilever beam with anisotropic material properties. The humerus bone is the long bone in the arm that connects the shoulder to the elbow. The mode shape is assumed to be a higher-order polynomial satisfying a prescribed set of boundary conditions to converge the numerical algorithm. The natural frequency and the mode shapes are calculated for different boundary conditions to find the cross-sectional area of humerus bone from Eigenmode shape with the aid of the inverse mode shape algorithm. The cross-sectional area of humerus bone validates the mode shapes of specific boundary conditions. The numerical method to solve the inverse mode shape problem is validated in the biomedical application by finding the cross-sectional area of a humerus bone in the human arm.

Keywords: Cross-sectional area, Humerus bone, Inverse mode shape problem, Mode shape

Procedia PDF Downloads 93
993 Development of an Artificial Ear for Bone-Conducted Objective Occlusion Measurement

Authors: Yu Luan

Abstract:

The bone-conducted objective occlusion effect (OE) is characterized by a discomforting sensation of fullness experienced in an occluded ear. This phenomenon arises from various external stimuli, such as human speech, chewing, and walking, which generate vibrations transmitted through the body to the ear canal walls. The bone-conducted OE occurs due to the pressure build-up inside the occluded ear caused by sound radiating into the ear canal cavity from its walls. In the hearing aid industry, artificial ears are utilized as a tool for developing hearing aids. However, the currently available commercial artificial ears primarily focus on pure acoustics measurements, neglecting the bone-conducted vibration aspect. This research endeavors to develop an artificial ear specifically designed for bone-conducted occlusion measurements. Finite element analysis (FEA) modeling has been employed to gain insights into the behavior of the artificial ear.

Keywords: artificial ear, bone conducted vibration, occlusion measurement, finite element modeling

Procedia PDF Downloads 57
992 Preservation of Phenytoin and Sodium Valproate Induced Bone Loss by Raloxifene through Modulating Serum Estradiol and TGF-β3 Content in Bone of Female Mice

Authors: Divya Vohora, Md. Jamir Anwar

Abstract:

Antiepileptic drugs (AEDs)-induced adverse consequences on bone are now well recognized. Despite this, there is limited data on the effect of anti-osteoporotic therapies on AEDs-induced bone loss. Both phenytoin (PHT) and sodium valproate (SVP) inhibit human aromatase enzyme and stimulate microsomal catabolism of oestrogens. Estrogen deficiency states are known to reduce the deposition of transforming growth factor-β (TGF-β3), a bone matrix protein, having anti-osteoclastic property. Thus, an attempt was made to investigate the effect of raloxifene, a selective oestrogen receptor modulator, in comparison with CVD supplementation, on PHT and SVP-induced alterations in bone in mice. Further, the effect of raloxifene on seizures and on the antiepileptic efficacy of AEDs was also investigated. Swiss strains of female mice were treated with PHT (35 mg/kg, p.o.) and SVP (300 mg/kg, p.o.) for 120 days to induce bone loss as evidenced by reduced bone mineral density (BMD) and altered bone turnover markers in lumbar bones (alkaline phosphatase, tartarate resistant acid phosphatase, hydroxyproline) and urine (calcium). The bone loss was accompanied by reduced serum estradiol levels and bone TGF-β3 content. Preventive and curative treatment with raloxifene ameliorated bony alterations and was more effective than CVD. Deprived estrogen levels (that in turn reduced lumbar TGF-β3 content) following PHT and SVP, thus, might represent one of the various mechanisms of AEDs-induced bone loss. Raloxifene preserved the bony changes without interfering with their antiepileptic efficacy, and hence raloxifene could be a potential therapeutic option in the management of PHT and SVP-induced bone disease if clinically approved.

Keywords: antiepileptic drugs, osteoporosis, raloxifene, TGF-β3

Procedia PDF Downloads 311
991 Performance Evaluation of Next Generation Shale Stabilizer

Authors: N. K. Thakur

Abstract:

A major proportion of the formations drilled for the production of hydrocarbons consists of clay containing shales. The petroleum industry has hugely investigated the role of clay minerals and their subsequent effect on wellbore stability during the drilling and production of hydrocarbons. It has been found that when the shale formation comes in contact with water-based drilling fluid, the interaction of clay minerals like montmorillonite with infiltrated water leads to hydration of the clay minerals, which causes shale swelling. When shale swelling proceeds further, it may lead to major drilling complications like caving, pipe sticking, which invariably influences wellbore stability, wellbore diameter, the mechanical strength of shale, stress distribution in the wellbore, etc. These problems ultimately lead to an increase in nonproductive time and additional costs during drilling. Several additives are used to prevent shale instability. Among the popular additives used for shale inhibition in drilling muds, ionic liquids and nanoparticles are emerging to be the best additives. The efficiency of the proposed additives will be studied and compared with conventional clay inhibitors like KCl. The main objective is to develop a highly efficient water-based mud for mitigating shale instability and reducing fluid loss which is environmentally friendly and does not alter the formation permeability. The use of nanoparticles has been exploited to enhance the rheological and fluid loss properties in water-based drilling fluid ionic liquid have attracted significant research interest due to its unique thermal stability. It is referred to as ‘green chemical’. The preliminary experimental studies performed are promising. The application of more effective mud additives is always desirable to make the drilling process techno-economically proficient.

Keywords: ionic liquid, shale inhibitor, wellbore stability, unconventional

Procedia PDF Downloads 157
990 Wellbore Stability Evaluation of Ratawi Shale Formation

Authors: Raed Hameed Allawi

Abstract:

Wellbore instability problems are considered the majority challenge for several wells in the Ratawi shale formation. However, it results in non-productive (NPT) time and increased well-drilling expenditures. This work aims to construct an integrated mechanical earth model (MEM) to predict the wellbore failure and design optimum mud weight to improve the drilling efficiency of future wells. The MEM was based on field data, including open-hole wireline logging and measurement data. Several failure criteria were applied in this work, including Modified Lade, Mogi-Coulomb, and Mohr-Coulomb that utilized to calculate the proper mud weight and practical drilling paths and orientations. Results showed that the leading cause of wellbore instability problems was inadequate mud weight. Moreover, some improper drilling practices and heterogeneity of Ratawi formation were additional causes of the increased risk of wellbore instability. Therefore, the suitable mud weight for safe drilling in the Ratawi shale formation should be 11.5-13.5 ppg. Furthermore, the mud weight should be increased as required depending on the trajectory of the planned well. The outcome of this study is as practical tools to reduce non-productive time and well costs and design future neighboring deviated wells to get high drilling efficiency. In addition, the current results serve as a reference for similar fields in that region because of the lacking of published studies regarding wellbore instability problems of the Ratawi Formation in southern Iraqi oilfields.

Keywords: wellbore stability, hole collapse, horizontal stress, MEM, mud window

Procedia PDF Downloads 153
989 Tool Damage and Adhesion Effects in Turning and Drilling of Hardened Steels

Authors: Chris M. Taylor, Ian Cook, Raul Alegre, Pedro Arrazola, Phil Spiers

Abstract:

Noteworthy results have been obtained in the turning and drilling of hardened high-strength steels using tungsten carbide based cutting tools. In a finish turning process, it was seen that surface roughness and tool flank wear followed very different trends against cutting time. The suggested explanation for this behaviour is that the profile cut into the workpiece surface is determined by the tool’s cutting edge profile. It is shown that the profile appearing on the cut surface changes rapidly over time, so the profile of the tool cutting edge should also be changing rapidly. Workpiece material adhered onto the cutting tool, which is also known as a built-up edge, is a phenomenon which could explain the observations made. In terms of tool damage modes, workpiece material adhesion is believed to have contributed to tool wear in examples provided from finish turning, thread turning and drilling. Additionally, evidence of tool fracture and tool abrasion were recorded.

Keywords: turning, drilling, adhesion, wear, hard steels

Procedia PDF Downloads 308
988 Differentiated Thyroid Cancer Presenting with Solitary Bony Metastases to the Frontal Bone of the Skull

Authors: Christy M. Moen, Richard B. Townsley

Abstract:

Introduction: Metastasis to the frontal bone in thyroid cancer is extremely rare. A literature review found only six cases of thyroid cancer that metastasised to the frontal bone, with two of those involving further bone sites. Case Report: The patient was originally referred to the Oral and Maxillofacial Surgery team with an isolated mass on her forehead. Biopsies were performed, which showed this was likely a metastatic deposit from thyroid cancer. CT-PET scan showed this was an isolated lesion. The patient had a total thyroidectomy, and the forehead lesion was managed with radiotherapy. On interval scanning, the patient’s bony lesion had increased in size and had new lung nodules, which likely represented further metastasis. Conclusion: Isolated bony metastases to the frontal bone are rare. An important clinical principle to remember is that a bony metastasis from an unknown primary is more likely than primary bone cancer.

Keywords: cancer, thyroid, head and neck, surgery

Procedia PDF Downloads 166
987 Bone Mineral Density and Quality, Body Composition of Women in the Postmenopausal Period

Authors: Vladyslav Povoroznyuk, Oksana Ivanyk, Nataliia Dzerovych

Abstract:

In the diagnostics of osteoporosis, the gold standard is considered to be bone mineral density; however, X-ray densitometry is not an accurate indicator of osteoporotic fracture risk under all circumstances. In this regard, the search for new methods that could determine the indicators not only of the mineral density, but of the bone tissue quality, is a logical step for diagnostic optimization. One of these methods is the evaluation of trabecular bone quality. The aim of this study was to examine the quality and mineral density of spine bone tissue, femoral neck, and body composition of women depending on the duration of the postmenopausal period, to determine the correlation of body fat with indicators of bone mineral density and quality. The study examined 179 women in premenopausal and postmenopausal periods. The patients were divided into the following groups: Women in the premenopausal period and women in the postmenopausal period at various stages (early, middle, late postmenopause). A general examination and study of the above parameters were conducted with General Electric X-ray densitometer. The results show that bone quality and mineral density probably deteriorate with advancing of postmenopausal period. Total fat and lean mass ratio is not likely to change with age. In the middle and late postmenopausal periods, the bone tissue mineral density of the spine and femoral neck increases along with total fat mass.

Keywords: osteoporosis, bone tissue mineral density, bone quality, fat mass, lean mass, postmenopausal osteoporosis

Procedia PDF Downloads 311
986 Stimulation of NCAM1-14.3.3.ζδ-derived Peptide Interaction Fuels Angiogenesis and Osteogenesis in Ageing

Authors: Taha Kadir Yesin, Hanyu Liu, Zhangfan Ding, Amit Singh, Qi Tian, Yuheng Zhang, Biswajyoti Borah, Junyu Chen, Anjali P. Kusumbe

Abstract:

The skeletal structure and bone marrow endothelium collectively form a critical functional unit essential for bone development, health, and aging. At the core of osteogenesis and bone formation lies the dynamic process of angiogenesis. In this study, we reveal a potent endogenous anabolic NCAM1-14.3.3. ζδ-derived- Peptide interaction, which stimulates bone angiogenesis and osteogenesis during homeostasis, aging, and age-related bone diseases. Employing high-resolution imaging and inducible cell-specific mouse genetics, our results elucidate the pivotal role of the NCAM1-14.3.3.ζδ-derived-Peptide interaction in driving the expansion of Clec14a+ angiogenic endothelial cells. Notably, Clec14a+ endothelial cells express key osteogenic factors. The NCAM1-14.3.3.ζδ-derived-Peptide interaction in osteoblasts drives osteoblast differentiation, ultimately contributing to the genesis of bone. Moreover, the NCAM1-14.3.3.ζδ-derived-Peptide interaction leads to a reduction in bone resorption. In age-associated vascular and bone loss diseases, stimulating the NCAM1-14.3.3.ζδ-derived-Peptide interaction not only promotes angiogenesis but also reverses bone loss. Consequently, harnessing the endogenous anabolic potential of the NCAM1-14.3.3.ζδ-derived-Peptide interaction emerges as a promising therapeutic modality for managing age-related bone diseases.

Keywords: endothelial cell, NCAM1, Clec14a, 14.3.3.ζδ

Procedia PDF Downloads 26
985 Production and Quality Control of a Novel 153Sm-Complex for Radiotherapy of Bone-Metastases

Authors: H. Yousefnia, R. Enayati, M. Hosntalab, S. Zolghadri, A. Bahrami-Samani

Abstract:

Bone metastases occur in many cases at an early stage of the tumour disease, however their symptoms are recognized rather late. The aim of this study was the preparation of 153Sm-(4-{[bis-(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl) 1,4,7,10-tetraazacyclododec-1-yl) acetic acid (BPAMD) for bone pain palliation therapy. 153Sm was produced at Tehran research reactor via 152Sm(n,γ)153Sm reaction. 200 µl of 1mg/ml BPAMD solution was added to the vial containing 1 mCi 153Sm and the mixture was heated up to 90 0C for 1 h. The radiochemical purity of the complex was measured by ITLC method. The final solution with radiochemical purity of more than 95% was injected to BALB mice and bio distribution was determined up to 48 h. SPECT images were acquired after 2 and 24 h post injection. While high bone uptake was confirmed by both the bio distribution studies and SPECT imaging, accumulation in other organs was approximately negligible. The results show that 153Sm-BPAMD can be used as an excellent tracer for bone pain palliation therapy.

Keywords: bone metastases, BPAMD, 153Sm, radiotherapy

Procedia PDF Downloads 572
984 Combined Power Supply at Well Drilling in Extreme Climate Conditions

Authors: V. Morenov, E. Leusheva

Abstract:

Power supplying of well drilling on oil and gas fields at ambient air low temperatures is characterized by increased requirements of electric and heat energy. Power costs for heating of production facilities, technological and living objects may several times exceed drilling equipment electric power consumption. Power supplying of prospecting and exploitation drilling objects is usually done by means of local electric power structures based on diesel power stations. In the meantime, exploitation of oil fields is accompanied by vast quantities of extracted associated petroleum gas, and while developing gas fields there are considerable amounts of natural gas and gas condensate. In this regard implementation of gas-powered self-sufficient power units functioning on produced crude products for power supplying is seen as most potential. For these purposes gas turbines (GT) or gas reciprocating engines (GRE) may be used. In addition gas-powered units are most efficiently used in cogeneration mode - combined heat and power production. Conducted research revealed that GT generate more heat than GRE while producing electricity. One of the latest GT design are microturbines (MT) - devices that may be efficiently exploited in combined heat and power mode. In conditions of ambient air low temperatures and high velocity wind sufficient heat supplying is required for both technological process, specifically for drilling mud heating, and for maintaining comfortable working conditions at the rig. One of the main heat regime parameters are the heat losses. Due to structural peculiarities of the rig most of the heat losses occur at cold air infiltration through the technological apertures and hatchways and heat transition of isolation constructions. Also significant amount of heat is required for working temperature sustaining of the drilling mud. Violation of circulation thermal regime may lead to ice build-up on well surfaces and ice blockages in armature elements. That is why it is important to ensure heating of the drilling mud chamber according to ambient air temperature. Needed heat power will be defined by heat losses of the chamber. Noting heat power required for drilling structure functioning, it is possible to create combined heat and power complex based on MT for satisfying consumer power needs and at the same time lowering power generation costs. As a result, combined power supplying scheme for multiple well drilling utilizing heat of MT flue gases was developed.

Keywords: combined heat, combined power, drilling, electric supply, gas-powered units, heat supply

Procedia PDF Downloads 556
983 The Contribution of Density Fluctuations in Ultrasound Scattering in Cancellous Bone

Authors: A. Elsariti, T. Evans

Abstract:

An understanding of the interaction between acoustic waves and cancellous bone is needed in order to realize the full clinical potential of ultrasonic bone measurements. Scattering is likely to be of central importance but has received little attention to date. Few theoretical approaches have been described to explain scattering of ultrasound from bone. In this study, a scattering model based on velocity and density fluctuations in a binary mixture (marrow fat and cortical matrix) was used to estimate the ultrasonic attenuation in cancellous bone as a function of volume fraction. Predicted attenuation and backscatter coefficient were obtained for a range of porosities and scatterer size. At 600 kHZ and for different scatterer size the effect of velocity and density fluctuations in the predicted attenuation was approximately 60% higher than velocity fluctuations.

Keywords: ultrasound scattering, sound speed, density fluctuations, attenuation coefficient

Procedia PDF Downloads 296
982 Development of 111In-DOTMP as a New Bone Imaging Agent

Authors: H. Yousefnia, S. Zolghadri, AR. Jalilian, A. Mirzaei, A. Bahrami-Samani, M. Erfani

Abstract:

The objective of this study is the preparation of 111In-DOTMP as a new bone imaging agent. 111In was produced at the Agricultural, Medical and Industrial Research School (AMIRS) by means of 30 MeV cyclotron via natCd(p,x)111In reaction. Complexion of In‐111 with DOTMP was carried out by adding 0.1 ml of the stock solution (50 mg/ml in 2 N NaoH) to the vial containing 1 mCi of 111In. pH of the mixture was adjusted to 7-8 by means of phosphate buffer. The radiochemical purity of the complex at the optimized condition was higher than 98% (by using whatman No.1 paper in NH4OH:MeOH: H2O (0.2:2:4)). Both the biodistribution studies and SPECT imaging indicated high bone uptake. The ratio of bone to other soft tissue accumulation was significantly high which permit to observe high quality images. The results show that 111In-DOTMP can be used as a suitable tracer for diagnosis of bone metastases by SPECT imaging.

Keywords: biodistribution, DOTMP, 111In, SPECT

Procedia PDF Downloads 506
981 Experimental Study of Impregnated Diamond Bit Wear During Sharpening

Authors: Rui Huang, Thomas Richard, Masood Mostofi

Abstract:

The lifetime of impregnated diamond bits and their drilling efficiency are in part governed by the bit wear conditions, not only the extent of the diamonds’ wear but also their exposure or protrusion out of the matrix bonding. As much as individual diamonds wear, the bonding matrix does also wear through two-body abrasion (direct matrix-rock contact) and three-body erosion (cuttings trapped in the space between rock and matrix). Although there is some work dedicated to the study of diamond bit wear, there is still a lack of understanding on how matrix erosion and diamond exposure relate to the bit drilling response and drilling efficiency, as well as no literature on the process that governs bit sharpening a procedure commonly implemented by drillers when the extent of diamond polishing yield extremely low rate of penetration. The aim of this research is (i) to derive a correlation between the wear state of the bit and the drilling performance but also (ii) to gain a better understanding of the process associated with tool sharpening. The research effort combines specific drilling experiments and precise mapping of the tool-cutting face (impregnated diamond bits and segments). Bit wear is produced by drilling through a rock sample at a fixed rate of penetration for a given period of time. Before and after each wear test, the bit drilling response and thus efficiency is mapped out using a tailored design experimental protocol. After each drilling test, the bit or segment cutting face is scanned with an optical microscope. The test results show that, under the fixed rate of penetration, diamond exposure increases with drilling distance but at a decreasing rate, up to a threshold exposure that corresponds to the optimum drilling condition for this feed rate. The data further shows that the threshold exposure scale with the rate of penetration up to a point where exposure reaches a maximum beyond which no more matrix can be eroded under normal drilling conditions. The second phase of this research focuses on the wear process referred as bit sharpening. Drillers rely on different approaches (increase feed rate or decrease flow rate) with the aim of tearing worn diamonds away from the bit matrix, wearing out some of the matrix, and thus exposing fresh sharp diamonds and recovering a higher rate of penetration. Although a common procedure, there is no rigorous methodology to sharpen the bit and avoid excessive wear or bit damage. This paper aims to gain some insight into the mechanisms that accompany bit sharpening by carefully tracking diamond fracturing, matrix wear, and erosion and how they relate to drilling parameters recorded while sharpening the tool. The results show that there exist optimal conditions (operating parameters and duration of the procedure) for sharpening that minimize overall bit wear and that the extent of bit sharpening can be monitored in real-time.

Keywords: bit sharpening, diamond exposure, drilling response, impregnated diamond bit, matrix erosion, wear rate

Procedia PDF Downloads 62
980 An Intelligent Steerable Drill System for Orthopedic Surgery

Authors: Wei Yao

Abstract:

A steerable and flexible drill is needed in orthopaedic surgery. For example, osteoarthritis is a common condition affecting millions of people for which joint replacement is an effective treatment which improves the quality and duration of life in elderly sufferers. Conventional surgery is not very accurate. Computer navigation and robotics can help increase the accuracy. For example, In Total Hip Arthroplasty (THA), robotic surgery is currently practiced mainly on acetabular side helping cup positioning and orientation. However, femoral stem positioning mostly uses hand-rasping method rather than robots for accurate positioning. The other case for using a flexible drill in surgery is Anterior Cruciate Ligament (ACL) Reconstruction. The majority of ACL Reconstruction failures are primarily caused by technical mistakes and surgical errors resulting from drilling the anatomical bone tunnels required to accommodate the ligament graft. The proposed new steerable drill system will perform orthopedic surgery through curved tunneling leading to better accuracy and patient outcomes. It may reduce intra-operative fractures, dislocations, early failure and leg length discrepancy by making possible a new level of precision. This technology is based on a robotically assisted, steerable, hand-held flexible drill, with a drill-tip tracking device and a multi-modality navigation system. The critical differentiator is that this robotically assisted surgical technology now allows the surgeon to prepare 'patient specific' and more anatomically correct 'curved' bone tunnels during orthopedic surgery rather than drilling straight holes as occurs currently with existing surgical tools. The flexible and steerable drill and its navigation system for femoral milling in total hip arthroplasty had been tested on sawbones to evaluate the accuracy of the positioning and orientation of femoral stem relative to the pre-operative plan. The data show the accuracy of the navigation system is better than traditional hand-rasping method.

Keywords: navigation, robotic orthopedic surgery, steerable drill, tracking

Procedia PDF Downloads 142
979 The Influence of Viscosifier Concentration on Rheological Properties of Invert Emulsion Mud

Authors: Suzan Ibrahim

Abstract:

Oil-based muds are the most regularly used rotary drilling methods in the oil and gas industry. However, they have a negative impact on the environment, which leads to restrictions of their application in many countries of the world. Consequently, looking for new eco-friendly alternative formulations of oil-based drilling fluids for the exploration of troublesome formations. As one of the developments of Novel formulation of environmentally friendly drilling fluids and investigation of the formulation for jatropha oil-based drilling fluid samples at different concentrations of viscosifiers such as low viscosity polyanionic cellulose (PAC- LV), high viscosity polyanionic cellulose (PAC-V) and local Egyptian bentonite. The oil-water ratio was taken as 70:30, which is beneficial in producing a low fluid loss. 15 drilling fluid samples were formulated different concentrations of bentonite, PAC- LV and PAC-V individually and their mud density, rheological properties, electrical stability and filtration loss properties were determined. The rheological performance showed at higher concentrations of viscosifier, the trend of viscosity increment of PAC performed in a similar way to bentonite. The best result of electrical stability by using the lowest concentration of viscosifier was achieved with PAC-V. The lowest fluid loss volumes were obtained by using the highest concentrations (4 g) of viscosifiers. Mud cake thickness of samples increased by using viscosifiers; however, a lower range was achieved compared to API specification. From the overall experiment, it can be concluded that as the concentrations of viscosifier increase, the viscosity trend increase in a similar way to both PAC-V and bentonite. But we must note that the PAC-V is a more environmentally friendly additive and a renewable resource, cheaper than bentonite and improves properties of eco-friendly OBMs well. It is a preferable choice for oil-based drilling fluids.

Keywords: invert emulsion mud, oil-based mud, rheological properties, viscosifier

Procedia PDF Downloads 141
978 Enhancing Single Channel Minimum Quantity Lubrication through Bypass Controlled Design for Deep Hole Drilling with Small Diameter Tool

Authors: Yongrong Li, Ralf Domroes

Abstract:

Due to significant energy savings, enablement of higher machining speed as well as environmentally friendly features, Minimum Quantity Lubrication (MQL) has been used for many machining processes efficiently. However, in the deep hole drilling field (small tool diameter D < 5 mm) and long tool (length L > 25xD) it is always a bottle neck for a single channel MQL system. The single channel MQL, based on the Venturi principle, faces a lack of enough oil quantity caused by dropped pressure difference during the deep hole drilling process. In this paper, a system concept based on a bypass design has explored its possibility to dynamically reach the required pressure difference between the air inlet and the inside of aerosol generator, so that the deep hole drilling demanded volume of oil can be generated and delivered to tool tips. The system concept has been investigated in static and dynamic laboratory testing. In the static test, the oil volume with and without bypass control were measured. This shows an oil quantity increasing potential up to 1000%. A spray pattern test has demonstrated the differences of aerosol particle size, aerosol distribution and reaction time between single channel and bypass controlled single channel MQL systems. A dynamic trial machining test of deep hole drilling (drill tool D=4.5mm, L= 40xD) has been carried out with the proposed system on a difficult machining material AlSi7Mg. The tool wear along a 100 meter drilling was tracked and analyzed. The result shows that the single channel MQL with a bypass control can overcome the limitation and enhance deep hole drilling with a small tool. The optimized combination of inlet air pressure and bypass control results in a high quality oil delivery to tool tips with a uniform and continuous aerosol flow.

Keywords: deep hole drilling, green production, Minimum Quantity Lubrication (MQL), near dry machining

Procedia PDF Downloads 175
977 Production, Quality Control and Biodistribution Assessment of 166 Ho-BPAMD as a New Bone Seeking Agent

Authors: H. Yousefnia, N. Amraee, M. Hosntalab, S. Zolghadri, A. Bahrami-Samani

Abstract:

The aim of this study was the preparation of a new agent for bone marrow ablation in patients with multiple myeloma. 166Ho was produced at Tehran research reactor via 165Ho(n,γ)166Ho reaction. Complexion of Ho‐166 with BPAMD was carried out by the addition of about 200µg of BPAMD in absolute water to 1 mci of 166HoCl3 and warming up the mixture 90 0C for 1 h. 166Ho-BPAMD was prepared successfully with radio chemical purity of 95% which was measured by ITLC method. The final solution was injected to wild-type mice and bio distribution was determined up to 48 h. SPECT images were acquired after 2 and 48 h post injection. Both the bio distribution studies and SPECT imaging indicated high bone uptake, while accumulation in other organs was approximately negligible. The results show that 166Ho-BPAMD has suitable characteristics and can be used as a new bone marrow ablative agent.

Keywords: bone marrow ablation, BPAMD, 166Ho, SPECT

Procedia PDF Downloads 477
976 Effect of TERGITOL NP-9 and PEG-10 Oleyl Phosphate as Surfactant and Corrosion Inhibitor on Tribo-Corrosion Performance of Carbon Steel in Emulsion-Based Drilling Fluids

Authors: Mohammadjavad Palimi, D. Y. Li, E. Kuru

Abstract:

Emulsion-based drilling fluids containing mineral oil are commonly used for drilling operations, which generate a lubricating film to prevent direct contact between moving metal parts, thus reducing friction, wear, and corrosion. For long-lasting lubrication, the thin lubricating film formed on the metal surface should possess good anti-wear and anti-corrosion capabilities. This study aims to investigate the effects of two additives, TERGITOL NP-9 and PEG-10 oleyl phosphate, acting as surfactant and corrosion inhibitor, respectively, on the tribo-corrosion behavior of 1018 carbon steel immersed in 5% KCl solution at room temperature. A pin-on-disc tribometer attached to an electrochemical system was used to investigate the corrosive wear of the steel immersed in emulsion-based fluids containing the surfactant and corrosion inhibitor. The wear track, surface chemistry and composition of the protective film formed on the steel surface were analyzed with an optical profilometer, SEM, and SEM-EDX. Results of the study demonstrate that the performance of the emulsion-based drilling fluids was significantly improved by the corrosion inhibitor by a remarkable reduction in corrosion, coefficient of friction (COF) and wear.

Keywords: corrosion inhibitor, emulsion-based drilling fluid, tribo-corrosion, friction, wear

Procedia PDF Downloads 43
975 Risk Association of RANKL and OPG Gene Polymorphism with Breast to Bone Metastasis

Authors: Najeeb Ullah Khan

Abstract:

Background: The receptor activator NF-κβ ligand (RANKL) and Osteoprotegerin (OPG) polymorphisms have been associated with the progression of breast cancer to bone metastasis. Here, we aimed to investigate the association of RANKL and OPG gene polymorphism with breast to bone metastasis in the Pashtun population, Pakistan. Methods: Genomic DNA was obtained from all the study subjects (106 breast cancer, 58 breast to bone metastasis, and 51 healthy controls). RANKL (rs9533156) and OPG (rs2073618, rs3102735) polymorphisms were genotyped using Tetra-ARMS PCR. Results: Our results indicated that the frequencies of OPG (rs3102735) risk allele and genotypes carrying risk allele in breast cancer vs healthy control (C- p=0.005; CC- p=0.0208; TC- p=0.0181), bone metastasis vs healthy control (C- p=0.0211; CC- p=0.0153; TC- p=0.0775), and breast cancer vs breast to bone metastasis (C- p=0.0001; CC- p=0.0001; TC- p=0.001) were found significantly associated with disease risk. However, there was no significant association observed for OPG (rs2073618) risk allele and risk allele containing genotypes in all study groups. Similarly, RANKL (rs9533156) risk alleles and corresponding genotypes in breast cancer vs healthy control (C- p=0.0001; CC- p=0.0001; TC- p=0.0084), bone metastasis vs healthy control (C- p=0.0001; CC- p=0.0001; TC- p=0.5593), and breast cancer vs breast to bone metastasis (C- p=0.0185; CC- p=0.6077; TC- p=0.1436) showed significant association except for the risk allele carrying genotypes in breast cancer to bone metastasis (TC, p=0.1436; CC, p=0.6077). Conclusion: OPG (rs3102735) and RANKL (rs9533156) showed significant association with breast to bone metastasis, while OPG (rs2073618) didn’t show a significant association with breast to bone metastasis in Pashtun population of Pakistan. However, more investigation will be required to disseminate the results while gene sequencing or whole-exome sequencing.

Keywords: breast cancer, bone metastasis, OPG, RANKL, polymorphism

Procedia PDF Downloads 162
974 Psychological Aspects of Quality of Life in Patients with Primary and Metastatic Bone Tumors

Authors: O. Yu Shchelkova, E. B. Usmanova

Abstract:

Introduction: Last decades scientific research of quality of life (QoL) is developing fast worldwide. QoL concept pays attention to emotional experience of disease in patients, particularly to personal sense of possibility to satisfy actual needs and possibility of full social functioning in spite of disease limitations. QoL in oncological patients is studied intensively. Nevertheless, the issue of QoL in patients with bone tumors focused on psychological factors of QoL and relation to disease impact on QoL is not discussed. The aim of the study was to reveal the basic aspects and personality factors of QoL in patients with bone tumor. Results: Study participants were 139 patients with bone tumors. The diagnoses were osteosarcoma (n=42), giant cell tumor (n=32), chondrosarcoma (n=32), Ewing sarcoma (n=10) and bone metastases (n=23). The study revealed that patients with bone metastases assess their health significantly worse than other patients. Besides patients with osteosarcoma evaluate their general health higher than patients with giant cell tumors. Social functioning in patients with chondrosarcoma is higher than in patients with bone metastases and patients with giant cell tumor. Patients with chondrosarcoma have higher physical functioning and less restricted in daily activities than patients with bone metastases. Patients with bone metastases characterize their pain as more widespread than patients with primary bone tumors and have more functional restrictions due to bone incision. Moreover, the study revealed personality significant influence on QoL related to bone tumors. Such characteristics in structure of personality as high degree of self-consciousness, personal resources, cooperation and disposition to positive reappraisal in difficult situation correspond to higher QoL. Otherwise low personal resources and slight problem solving behaviour, low degree of self-consciousness and high social dependence correspond to decrease of QoL in patients with bone tumors. Conclusion: Patients with bone metastasis have lower QoL compared to patients with primary bone tumors. Patients with giant cell tumor have the worth quality of life among patients with primary bone tumors. Furthermore, the results revealed differences in QoL parameters associated with personality characteristics in patients with bone tumors. Such psychological factors as future goals, interest in life and emotional saturation, besides high degree of personal resources and cooperation influence on increasing QoL in patients with bone tumors.

Keywords: quality of life, psychological factors, bone tumor, personality

Procedia PDF Downloads 117
973 Biodegradable and Bioactive Scaffold for Bone Tissue Engineering

Authors: A. M. Malagon Escandon, J. A. Arenas Alatorre, C. P. Chaires Rosas, N. A. Vazquez Torres, B. Hernandez Tellez, G. Pinon Zarate, M. Herrera Enriquez, A. E. Castell Rodriguez

Abstract:

The current approach to the treatment of bone defects involves the use of scaffolds that provide a biological and mechanically stable niche to favor tissue repair. Despite the significant progress in the field of bone tissue engineering, several main problems associated are attributed to giving a low biodegradation degree, does not promote osseointegration and regeneration, if the bone is not healing as well as expected or fails to heal, will not be given a proper ossification or new bone formation. The actual approaches of bone tissue regeneration are directed to the use of decellularized native extracellular matrices, which are able of retain their own architecture, mechanic properties, biodegradability and promote new bone formation because they are capable of conserving proteins and other factors that are founded in physiological concentrations. Therefore, we propose an extracellular matrix-based bioscaffolds derived from bovine cancellous bone, which is processed by decellularization, demineralization, and hydrolysis of the collagen protein, these protocols have been successfully carried out in other organs and tissues; the effectiveness of its biosafety has also been previously evaluated in vivo and Food and Drug Administration (FDA) approved. In the specific case of bone, a more complex treatment is needed in comparison with other organs and tissues because is necessary demineralization and collagen denaturalization. The present work was made in order to obtain a temporal scaffold that succeed in degradation in an inversely proportional way to the synthesis of extracellular matrix and the maturation of the bone by the cells of the host.

Keywords: bioactive, biodegradable, bone, extracellular matrix-based bioscaffolds, stem cells, tissue engineering

Procedia PDF Downloads 123
972 Relation between Biochemical Parameters and Bone Density in Postmenopausal Women with Osteoporosis

Authors: Shokouh Momeni, Mohammad Reza Salamat, Ali Asghar Rastegari

Abstract:

Background: Osteoporosis is the most prevalent metabolic bone disease in postmenopausal women associated with reduced bone mass and increased bone fracture. Measuring bone density in the lumbar spine and hip is a reliable measure of bone mass and can therefore specify the risk of fracture. Dual-energy X-ray absorptiometry(DXA) is an accurate non-invasive system measuring the bone density, with low margin of error and no complications. The present study aimed to investigate the relationship between biochemical parameters with bone density in postmenopausal women. Materials and methods: This cross-sectional study was conducted on 87 postmenopausal women referred to osteoporosis centers in Isfahan. Bone density was measured in the spine and hip area using DXA system. Serum levels of calcium, phosphorus, alkaline phosphatase and magnesium were measured by autoanalyzer and serum levels of vitamin D were measured by high-performance liquid chromatography(HPLC). Results: The mean parameters of calcium, phosphorus, alkaline phosphatase, vitamin D and magnesium did not show a significant difference between the two groups(P-value>0.05). In the control group, the relationship between alkaline phosphatase and BMC and BA in the spine was significant with a correlation coefficient of -0.402 and 0.258, respectively(P-value<0.05) and BMD and T-score in the femoral neck area showed a direct and significant relationship with phosphorus(Correlation=0.368; P-value=0.038). There was a significant relationship between the Z-score with calcium(Correlation=0.358; P-value=0.044). Conclusion: There was no significant relationship between the values ​​of calcium, phosphorus, alkaline phosphatase, vitamin D and magnesium parameters and bone density (spine and hip) in postmenopaus

Keywords: osteoporosis, menopause, bone mineral density, vitamin d, calcium, magnesium, alkaline phosphatase, phosphorus

Procedia PDF Downloads 136