Search results for: uniaxial compression test
7350 Enhancement of Mechanical Properties for Al-Mg-Si Alloy Using Equal Channel Angular Pressing
Authors: W. H. El Garaihy, A. Nassef, S. Samy
Abstract:
Equal channel angular pressing (ECAP) of commercial Al-Mg-Si alloy was conducted using two strain rates. The ECAP processing was conducted at room temperature and at 250 °C. Route A was adopted up to a total number of four passes in the present work. Structural evolution of the aluminum alloy discs was investigated before and after ECAP processing using optical microscopy (OM). Following ECAP, simple compression tests and Vicker’s hardness were performed. OM micrographs showed that, the average grain size of the as-received Al-Mg-Si disc tends to be larger than the size of the ECAP processed discs. Moreover, significant difference in the grain morphologies of the as-received and processed discs was observed. Intensity of deformation was observed via the alignment of the Al-Mg-Si consolidated particles (grains) in the direction of shear, which increased with increasing the number of passes via ECAP. Increasing the number of passes up to 4 resulted in increasing the grains aspect ratio up to ~5. It was found that the pressing temperature has a significant influence on the microstructure, Hv-values, and compressive strength of the processed discs. Hardness measurements demonstrated that 1-pass resulted in increase of Hv-value by 42% compared to that of the as-received alloy. 4-passes of ECAP processing resulted in additional increase in the Hv-value. A similar trend was observed for the yield and compressive strength. Experimental data of the Hv-values demonstrated that there is a lack of any significant dependence on the processing strain rate.Keywords: Al-Mg-Si alloy, equal channel angular pressing, grain refinement, severe plastic deformation
Procedia PDF Downloads 4357349 The Influence of Audio on Perceived Quality of Segmentation
Authors: Silvio Ricardo Rodrigues Sanches, Bianca Cogo Barbosa, Beatriz Regina Brum, Cléber Gimenez Corrêa
Abstract:
To evaluate the quality of a segmentation algorithm, the authors use subjective or objective metrics. Although subjective metrics are more accurate than objective ones, objective metrics do not require user feedback to test an algorithm. Objective metrics require subjective experiments only during their development. Subjective experiments typically display to users some videos (generated from frames with segmentation errors) that simulate the environment of an application domain. This user feedback is crucial information for metric definition. In the subjective experiments applied to develop some state-of-the-art metrics used to test segmentation algorithms, the videos displayed during the experiments did not contain audio. Audio is an essential component in applications such as videoconference and augmented reality. If the audio influences the user’s perception, using only videos without audio in subjective experiments can compromise the efficiency of an objective metric generated using data from these experiments. This work aims to identify if the audio influences the user’s perception of segmentation quality in background substitution applications with audio. The proposed approach used a subjective method based on formal video quality assessment methods. The results showed that audio influences the quality of segmentation perceived by a user.Keywords: background substitution, influence of audio, segmentation evaluation, segmentation quality
Procedia PDF Downloads 1177348 Efficacy Of Tranexamic Acid On Blood Loss After Primary Total Hip Replacement : A Case-control Study In 154 Patients
Authors: Fedili Benamar, Belloulou Mohamed Lamine, Ouahes Hassane, Ghattas Samir
Abstract:
Introduction: Perioperative blood loss is a frequent cause of complications in total hip replacement (THR). The present prospective study assessed the efficacy of tranexamic acid (Exacyl(®)) in reducing blood loss in primary THR. Hypothesis: Tranexamic acid reduces blood loss in THR. Material and method: -This is a prospective randomized study on the effectiveness of Exacyl (tranexamic acid) in total hip replacement surgery performed on a standardized technique between 2019 and September 2022. -It involved 154 patients, of which 84 received a single injection of Exacyl (group 1) at a dosage of 10 mg/kg over 20 minutes during the perioperative period. -All patients received postoperative thromboprophylaxis with enoxaparin 0.4 ml subcutaneously. -All patients were admitted to the post-interventional intensive care unit for a duration of 24 hours for monitoring and pain management as per the service protocol. Results: 154 patients, of which 84 received a single injection of Exacyl (group 1) and 70 patients patients who did not receive Exacyl perioperatively : (Group 2 ) The average age is 57 +/- 15 years The distribution by gender was nearly equal with 56% male and 44% female; "The distribution according to the ASA score was as follows: 20.2% ASA1, 82.3% ASA2, and 17.5% ASA3. "There was a significant difference in the average volume of intraoperative and postoperative bleeding during the 48 hours." The average bleeding volume for group 1 (received Exacyl) was 614 ml +/- 228, while the average bleeding volume for group 2 was 729 +/- 300, with a chi-square test of 6.35 and a p-value < 0.01, which is highly significant. The ANOVA test showed an F-statistic of 7.11 and a p-value of 0.008. A Bartlett test revealed a chi-square of 6.35 and a p-value < 0.01." "In Group 1 (patients who received Exacyl), 73% had bleeding less than 750 ml (Group A), and 26% had bleeding exceeding 750 ml (Group B). In Group 2 (patients who did not receive Exacyl perioperatively), 52% had bleeding less than 750 ml (Group A), and 47% had bleeding exceeding 750 ml (Group B). "Thus, the use of Exacyl reduced perioperative bleeding and specifically decreased the risk of severe bleeding exceeding 750 ml by 43% with a relative risk (RR) of 1.37 and a p-value < 0.01. The transfusion rate was 1.19% in the population of Group 1 (Exacyl), whereas it was 10% in the population of Group 2 (no Exacyl). It can be stated that the use of Exacyl resulted in a reduction in perioperative blood transfusion with an RR of 0.1 and a p-value of 0.02. Conclusions: The use of Exacyl significantly reduced perioperative bleeding in this type of surgery.Keywords: acid tranexamic, blood loss, anesthesia, total hip replacement, surgery
Procedia PDF Downloads 777347 Convective Boiling of CO₂/R744 in Macro and Micro-Channels
Authors: Adonis Menezes, J. C. Passos
Abstract:
The current panorama of technology in heat transfer and the scarcity of information about the convective boiling of CO₂ and hydrocarbon in small diameter channels motivated the development of this work. Among non-halogenated refrigerants, CO₂/ R744 has distinct thermodynamic properties compared to other fluids. The R744 presents significant differences in operating pressures and temperatures, operating at higher values compared to other refrigerants, and this represents a challenge for the design of new evaporators, as the original systems must normally be resized to meet the specific characteristics of the R744, which creates the need for a new design and optimization criteria. To carry out the convective boiling tests of CO₂, an experimental apparatus capable of storing (m= 10kg) of saturated CO₂ at (T = -30 ° C) in an accumulator tank was used, later this fluid was pumped using a positive displacement pump with three pistons, and the outlet pressure was controlled and could reach up to (P = 110bar). This high-pressure saturated fluid passed through a Coriolis type flow meter, and the mass velocities varied between (G = 20 kg/m².s) up to (G = 1000 kg/m².s). After that, the fluid was sent to the first test section of circular cross-section in diameter (D = 4.57mm), where the inlet and outlet temperatures and pressures, were controlled and the heating was promoted by the Joule effect using a source of direct current with a maximum heat flow of (q = 100 kW/m²). The second test section used a cross-section with multi-channels (seven parallel channels) with a square cross-section of (D = 2mm) each; this second test section has also control of temperature and pressure at the inlet and outlet as well as for heating a direct current source was used, with a maximum heat flow of (q = 20 kW/m²). The fluid in a biphasic situation was directed to a parallel plate heat exchanger so that it returns to the liquid state, thus being able to return to the accumulator tank, continuing the cycle. The multi-channel test section has a viewing section; a high-speed CMOS camera was used for image acquisition, where it was possible to view the flow patterns. The experiments carried out and presented in this report were conducted in a rigorous manner, enabling the development of a database on the convective boiling of the R744 in macro and micro channels. The analysis prioritized the processes from the beginning of the convective boiling until the drying of the wall in a subcritical regime. The R744 resurfaces as an excellent alternative to chlorofluorocarbon refrigerants due to its negligible ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) rates, among other advantages. The results found in the experimental tests were very promising for the use of CO₂ in micro-channels in convective boiling and served as a basis for determining the flow pattern map and correlation for determining the heat transfer coefficient in the convective boiling of CO₂.Keywords: convective boiling, CO₂/R744, macro-channels, micro-channels
Procedia PDF Downloads 1437346 The Biomechanical Assessment of Balance and Gait for Stroke Patients and the Implications in the Diagnosis and Rehabilitation
Authors: A. Alzahrani, G. Arnold, W. Wang
Abstract:
Background: Stroke commonly occurs in middle-aged and elderly populations, and the diagnosis of early stroke is still difficult. Patients who have suffered a stroke have different balance and gait patterns from healthy people. Advanced techniques of motion analysis have been routinely used in the clinical assessment of cerebral palsy. However, so far, little research has been done on the direct diagnosis of early stroke patients using motion analysis. Objectives: The aim of this study was to investigate whether patients with stroke have different balance and gait from healthy people and which biomechanical parameters could be used to predict and diagnose potential patients who are at a potential risk to stroke. Methods: Thirteen patients with stroke were recruited as subjects whose gait and balance was analysed. Twenty normal subjects at the matched age participated in this study as a control group. All subjects’ gait and balance were collected using Vicon Nexus® to obtain the gait parameters, kinetic, and kinematic parameters of the hip, knee, and ankle joints in three planes of both limbs. Participants stood on force platforms to perform a single leg balance test. Then, they were asked to walk along a 10 m walkway at their comfortable speed. Participants performed 6 trials of single-leg balance for each side and 10 trials of walking. From the recorded trials, three good ones were analysed using the Vicon Plug-in-Gait model to obtain gait parameters, e.g., walking speed, cadence, stride length, and joint parameters, e.g., joint angle, force, moments, etc. Result: The temporal-spatial variables of Stroke subjects were compared with the healthy subjects; it was found that there was a significant difference (p < 0.05) between the groups. The step length, speed, cadence were lower in stroke subjects as compared to the healthy groups. The stroke patients group showed significantly decreased in gait speed (mean and SD: 0.85 ± 0.33 m/s), cadence ( 96.71 ± 16.14 step/min), and step length (0.509 ± 017 m) in compared to healthy people group whereas the gait speed was 1.2 ± 0.11 m/s, cadence 112 ± 8.33 step/min, and step length 0.648 ± 0.43 m. Moreover, it was observed that patients with stroke have significant differences in the ankle, hip, and knee joints’ kinematics in the sagittal and coronal planes. Also, the result showed that there was a significant difference between groups in the single-leg balance test, e.g., maintaining single-leg stance time in the stroke patients showed shorter duration (5.97 ± 6.36 s) in compared to healthy people group (14.36 ± 10.20 s). Conclusion: Our result showed that there are significantly differences between stroke patients and healthy subjects in the various aspects of gait analysis and balance test, as a consequences of these findings some of the biomechanical parameters such as joints kinematics, gait parameters, and single-leg stance balance test could be used in clinical practice to predict and diagnose potential patients who are at a high risk of further stroke.Keywords: gait analysis, kinetics, kinematics, single-leg stance, Stroke
Procedia PDF Downloads 1427345 Group Sequential Covariate-Adjusted Response Adaptive Designs for Survival Outcomes
Authors: Yaxian Chen, Yeonhee Park
Abstract:
Driven by evolving FDA recommendations, modern clinical trials demand innovative designs that strike a balance between statistical rigor and ethical considerations. Covariate-adjusted response-adaptive (CARA) designs bridge this gap by utilizing patient attributes and responses to skew treatment allocation in favor of the treatment that is best for an individual patient’s profile. However, existing CARA designs for survival outcomes often hinge on specific parametric models, constraining their applicability in clinical practice. In this article, we address this limitation by introducing a CARA design for survival outcomes (CARAS) based on the Cox model and a variance estimator. This method addresses issues of model misspecification and enhances the flexibility of the design. We also propose a group sequential overlapweighted log-rank test to preserve type I error rate in the context of group sequential trials using extensive simulation studies to demonstrate the clinical benefit, statistical efficiency, and robustness to model misspecification of the proposed method compared to traditional randomized controlled trial designs and response-adaptive randomization designs.Keywords: cox model, log-rank test, optimal allocation ratio, overlap weight, survival outcome
Procedia PDF Downloads 647344 An Unexpected Helping Hand: Consequences of Redistribution on Personal Ideology
Authors: Simon B.A. Egli, Katja Rost
Abstract:
Literature on redistributive preferences has proliferated in past decades. A core assumption behind it is that variation in redistributive preferences can explain different levels of redistribution. In contrast, this paper considers the reverse. What if it is redistribution that changes redistributive preferences? The core assumption behind the argument is that if self-interest - which we label concrete preferences - and ideology - which we label abstract preferences - come into conflict, the former will prevail and lead to an adjustment of the latter. To test the hypothesis, data from a survey conducted in Switzerland during the first wave of the COVID-19 crisis is used. A significant portion of the workforce at the time unexpectedly received state money through the short-time working program. Short-time work was used as a proxy for self-interest and was tested (1) on the support given to hypothetical, ailing firms during the crisis and (2) on the prioritization of justice principles guiding state action. In a first step, several models using OLS-regressions on political orientation were estimated to test our hypothesis as well as to check for non-linear effects. We expected support for ailing firms to be the same regardless of ideology but only for people on short-time work. The results both confirm our hypothesis and suggest a non-linear effect. Far-right individuals on short-time work were disproportionally supportive compared to moderate ones. In a second step, ordered logit models were estimated to test the impact of short-time work and political orientation on the rankings of the distributive justice principles need, performance, entitlement, and equality. The results show that being on short-time work significantly alters the prioritization of justice principles. Right-wing individuals are much more likely to prioritize need and equality over performance and entitlement when they receive government assistance. No such effect is found among left-wing individuals. In conclusion, we provide moderate to strong evidence that unexpectedly finding oneself at the receiving end changes redistributive preferences if personal ideology is antithetical to redistribution. The implications of our findings on the study of populism, personal ideologies, and political change are discussed.Keywords: COVID-19, ideology, redistribution, redistributive preferences, self-interest
Procedia PDF Downloads 1407343 The Psychometric Properties of an Instrument to Estimate Performance in Ball Tasks Objectively
Authors: Kougioumtzis Konstantin, Rylander Pär, Karlsteen Magnus
Abstract:
Ball skills as a subset of fundamental motor skills are predictors for performance in sports. Currently, most tools evaluate ball skills utilizing subjective ratings. The aim of this study was to examine the psychometric properties of a newly developed instrument to objectively measure ball handling skills (BHS-test) utilizing digital instrument. Participants were a convenience sample of 213 adolescents (age M = 17.1 years, SD =3.6; 55% females, 45% males) recruited from upper secondary schools and invited to a sports hall for the assessment. The 8-item instrument incorporated both accuracy-based ball skill tests and repetitive-performance tests with a ball. Testers counted performance manually in the four tests (one throwing and three juggling tasks). Furthermore, assessment was technologically enhanced in the other four tests utilizing a ball machine, a Kinect camera and balls with motion sensors (one balancing and three rolling tasks). 3D printing technology was used to construct equipment, while all results were administered digitally with smart phones/tablets, computers and a specially constructed application to send data to a server. The instrument was deemed reliable (α = .77) and principal component analysis was used in a random subset (53 of the participants). Furthermore, latent variable modeling was employed to confirm the structure with the remaining subset (160 of the participants). The analysis showed good factorial-related validity with one factor explaining 57.90 % of the total variance. Four loadings were larger than .80, two more exceeded .76 and the other two were .65 and .49. The one factor solution was confirmed by a first order model with one general factor and an excellent fit between model and data (χ² = 16.12, DF = 20; RMSEA = .00, CI90 .00–.05; CFI = 1.00; SRMR = .02). The loadings on the general factor ranged between .65 and .83. Our findings indicate good reliability and construct validity for the BHS-test. To develop the instrument further, more studies are needed with various age-groups, e.g. children. We suggest using the BHS-test for diagnostic or assessment purpose for talent development and sports participation interventions that focus on ball games.Keywords: ball-handling skills, ball-handling ability, technologically-enhanced measurements, assessment
Procedia PDF Downloads 947342 Vascularized Adipose Tissue Engineering by Using Adipose ECM/Fibroin Hydrogel
Authors: Alisan Kayabolen, Dilek Keskin, Ferit Avcu, Andac Aykan, Fatih Zor, Aysen Tezcaner
Abstract:
Adipose tissue engineering is a promising field for regeneration of soft tissue defects. However, only very thin implants can be used in vivo since vascularization is still a problem for thick implants. Another problem is finding a biocompatible scaffold with good mechanical properties. In this study, the aim is to develop a thick vascularized adipose tissue that will integrate with the host, and perform its in vitro and in vivo characterizations. For this purpose, a hydrogel of decellularized adipose tissue (DAT) and fibroin was produced, and both endothelial cells and adipocytes that were differentiated from adipose derived stem cells were encapsulated in this hydrogel. Mixing DAT with fibroin allowed rapid gel formation by vortexing. It also provided to adjust mechanical strength by changing fibroin to DAT ratio. Based on compression tests, gels of DAT/fibroin ratio with similar mechanical properties to adipose tissue was selected for cell culture experiments. In vitro characterizations showed that DAT is not cytotoxic; on the contrary, it has many natural ECM components which provide biocompatibility and bioactivity. Subcutaneous implantation of hydrogels resulted with no immunogenic reaction or infection. Moreover, localized empty hydrogels gelled successfully around host vessel with required shape. Implantations of cell encapsulated hydrogels and histological analyses are under study. It is expected that endothelial cells inside the hydrogel will form a capillary network and they will bind to the host vessel passing through hydrogel.Keywords: adipose tissue engineering, decellularization, encapsulation, hydrogel, vascularization
Procedia PDF Downloads 5287341 Portable, Noninvasive and Wireless Near Infrared Spectroscopy Device to Monitor Skeletal Muscle Metabolism during Exercise
Authors: Adkham Paiziev, Fikrat Kerimov
Abstract:
Near Infrared Spectroscopy (NIRS) is one of the biophotonic techniques which can be used to monitor oxygenation and hemodynamics in a variety of human tissues, including skeletal muscle. In the present work, we are offering tissue oximetry (OxyPrem) to measure hemodynamic parameters of skeletal muscles in rest and exercise. Purpose: - To elaborate the new wireless, portable, noninvasive, wearable NIRS device to measure skeletal muscle oxygenation during exercise. - To test this device on brachioradialis muscle of wrestler volunteers by using combined method of arterial occlusion (AO) and NIRS (AO+NIRS). Methods: Oxyprem NIRS device has been used together with AO test. AO test and Isometric brachioradialis muscle contraction experiments have been performed on one group of wrestler volunteers. ‘Accu- Measure’ caliper (USA) to measure skinfold thickness (SFT) has been used. Results: Elaborated device consists on power supply box, a sensor head and installed ‘Tubis’ software for data acquisition and to compute deoxyhemoglobin ([HHb), oxyhemoglobin ([O2Hb]), tissue oxygenation (StO2) and muscle tissue oxygen consumption (mVO2). Sensor head consists on four light sources with three light emitting diodes with nominal wavelengths of 760 nm, 805 nm, and 870 nm, and two detectors. AO and isometric voluntary forearm muscle contraction (IVFMC) on five healthy male subjects (23,2±0.84 in age, 0.43±0.05cm of SFT ) and four female subjects (22.0±1.0 in age and 0.24±0.04 cm SFT) has been measured. mVO2 for control group has been calculated (-0.65%/sec±0.07) for male and -0.69%/±0.19 for female subjects). Tissue oxygenation index for wrestlers in average about 75% whereas for control group StO2 =63%. Second experiment was connected with quality monitoring muscle activity during IVFMC at 10%,30% and 50% of MVC. It has been shown, that the concentration changes of HbO2 and HHb positively correlated to the contraction intensity. Conclusion: We have presented a portable multi-channel wireless NIRS device for real-time monitoring of muscle activity. The miniaturized NIRS sensor and the usage of wireless communication make the whole device have a compact-size, thus can be used in muscle monitoring.Keywords: skeletal muscle, oxygenation, instrumentation, near infrared spectroscopy
Procedia PDF Downloads 2757340 Influence of Dry-Film Lubricants on Bond Strength and Corrosion Behaviour of 6xxx Aluminium Alloy Adhesive Joints for Automotive Industry
Authors: Ralph Gruber, Martina Hafner, Theresia Greunz, Christian Reisecker, David Stifter
Abstract:
The application of dry lubricant on aluminium for automotive industry is indispensable for a high-quality forming behaviour. To provide a short production time those forming aids will not be removed during the joining step. The aim of this study was the characterization of the influence of dry lubricants on the bond strength and the corrosion resistance of an 6xxx aluminium alloy for automotive applications. For this purpose, samples with a well-defined surface were lubricated with 1 g/m² dry lubricant and joined with a commercial thermosetting 1K-epoxy structural adhesive. The bond strength was characterized by means of lap shear test. To evaluate the corrosion resistance of the adhered aluminium samples an immersion test in 5 w% NaCl-solution was used. Based on fracture pattern analysis, the corrosion behaviour could be described. Dissolved corrosion products were examined using ICP-MS and NMR. By means of SEM/EDX the elementary composition of precipitated solids was determined. The results showed a dry lubricant independent bond strength for standard testing conditions. However, a significant effect of the forming aid, regarding the corrosion resistance of adhered aluminium samples against corrosive infiltration of the metal-adhesive-interface, was observedKeywords: aluminium alloys, dry film lubricants, automotive industry, adhesive bonding, corrosion
Procedia PDF Downloads 1027339 Influencing Factors on Stability of Shale with Silt Layers at Slopes
Authors: A. K. M. Badrul Alam, Yoshiaki Fujii, Nahid Hasan Dipu, Shakil Ahmed Razo
Abstract:
Shale rockmasses often include silt layers, impacting slope stability in construction and mining. Analyzing their interaction is crucial for long-term stability. A study used an elastoplastic model, incorporating the stress transfer method and Coulomb's criterion, to assess a shale rock mass with silt layers. It computed stress distribution, assessed failure potential, and identified vulnerable regions where nodal forces were calculated for a comprehensive analysis. A shale rock mass ranging from 14.75 to 16.75 meters thick, with silt layers varying from 0.36 to 0.5 meters, was considered in the model. It examined four silt layer conditions: horizontal (SiHL), vertical (SiVL), inclined against slope (SiIincAGS), and along slope (SilincALO). Mechanical parameters like uniaxial compressive strength (UCS), tensile strength (TS), Young’s modulus (E), Poisson’s ratio, and density were adjusted for varied scenarios: UCS (0.5 to 5 MPa), TS (0.1 to 1 MPa), and E (6 to 60 MPa). In elastic analysis of shale rock masses, stress distributions vary based on layer properties. When shale and silt layers have the same elasticity modulus (E), stress concentrates at corners. If the silt layer has a lower E than shale, marginal changes in maximum stress (σmax) occur for SilHL. A decrease in σmax is evident at SilVL. Slight variations in σmax are observed for SilincAGS and SilincALO. In the elastoplastic analysis, the overall decrease of 20%, 40%, 60%, 80%, and 90% was considered. For SilHL:(i) Same E, UCS, and TS for silt layer and shale, UCS/TS ratio 5: strength decrease led to shear (S), tension then shear (T then S) failure; noticeable failure at 60% decrease, significant at 80%, collapse at 90%. (ii) Lower E for silt layer, same strength as shale: No significant differences. (iii) Lower E and UCS, silt layer strength 1/10: No significant differences. For SilVL: (i) Same E, UCS, and TS for silt layer and shale, UCS/TS ratio 5: Similar effects as SilHL. (ii) Lower E for silt layer, same strength as shale: Slip occurred. (iii) Lower E and UCS, silt layer strength 1/10: Bitension failure also observed with larger slip. For SilincAGS: (i) Same E, UCS, and TS for silt layer and shale, UCS/TS ratio 5: Effects similar to SilHL. (ii) Lower E for silt layer, same strength as shale: Slip occurred. (iii) Lower E and UCS, silt layer strength 1/10: Tension failure also observed with larger slip. For SilincALO: (i) Same E, UCS, and TS for silt layer and shale, UCS/TS ratio 5: Similar to SilHL with tension failure. (ii) Lower E for silt layer, same strength as shale: No significant differences; failure diverged. (iii) Lower E and UCS, silt layer strength 1/10: Bitension failure also observed with larger slip; failure diverged. Toppling failure was observed for lower E cases of SilVL and SilincAGS. The presence of silt interlayers in shale greatly impacts slope stability. Designing slopes requires careful consideration of both the silt and shale's mechanical properties. The temporal degradation of strength in these layers is a major concern. Thus, slope design must comprehensively analyze the immediate and long-term mechanical behavior of interlayer silt and shale to effectively mitigate instability.Keywords: shale rock masses, silt layers, slope stability, elasto-plastic model, temporal degradation
Procedia PDF Downloads 567338 Investigation of Carbapenem-Resistant Genes in Acinetobacter spp. Isolated from Patients at Tertiary Health Care Center, Northeastern Thailand
Authors: S. J. Sirima, C. Thirawan, R.Puntharikorn, K. Ungsumalin, J. Kaemwich
Abstract:
Acinetobacter spp. is a gram negative bacterium causing the high incidence of multi-drug resistance in patients admitted to an intensive care unit. A hundred isolates of Imipenem-resistant Acinetobacter spp. isolated from patients admitted at tertiary health care center, Northeastern region, Ubon Ratchathani, Thailand, were subjected to modified Hodge test and combined disc test in order to evaluate the production of carbapenemases. The results revealed that about 35% of isolates were found to be carbapenemases producers. In addition, multiplex polymerase chain reactions were performed to detect blaOXA-like genes. It showed that 92% of isolates possess blaOXA-51-like and blaOXA-23-like genes. However, blaOXA-58-like gene was detected in only 8 isolates. No detection of blaOXA-24-like gene was observed in all isolates. In conclusion, an ability to produce carbepenemases would be an important mechanism of multi-drug resistance among clinical isolates of Acinetobacter spp. at tertiary health care center, Northeastern region, Ubon Ratchathani, Thailand. Furthermore, it was likely that the class D carbapenemases genes, blaOXA-51-like and blaOXA-23-like, might contribute to imipenem-resistance exhibiting among isolates.Keywords: Acinetobacter spp., blaOXA-like genes, carbapenemases, tertiary health care center
Procedia PDF Downloads 3827337 Observation of the Orthodontic Tooth's Long-Term Movement Using Stereovision System
Authors: Hao-Yuan Tseng, Chuan-Yang Chang, Ying-Hui Chen, Sheng-Che Chen, Chih-Han Chang
Abstract:
Orthodontic tooth treatment has demonstrated a high success rate in clinical studies. It has been agreed upon that orthodontic tooth movement is based on the ability of surrounding bone and periodontal ligament (PDL) to react to a mechanical stimulus with remodeling processes. However, the mechanism of the tooth movement is still unclear. Recent studies focus on the simple principle compression-tension theory while rare studies directly measure tooth movement. Therefore, tracking tooth movement information during orthodontic treatment is very important in clinical practice. The aim of this study is to investigate the mechanism responses of the tooth movement during the orthodontic treatments. A stereovision system applied to track the tooth movement of the patient with the stamp brackets. The system was established by two cameras with their relative position calibrate. And the orthodontic force measured by 3D printing model with the six-axis load cell to determine the initial force application. The result shows that the stereovision system accuracy revealed the measurement presents a maximum error less than 2%. For the study on patient tracking, the incisor moved about 0.9 mm during 60 days tracking, and half of movement occurred in the first few hours. After removing the orthodontic force in 100 hours, the distance between before and after position incisor tooth decrease 0.5 mm consisted with the release of the phenomenon. Using the stereovision system can accurately locate the three-dimensional position of the teeth and superposition of 3D coordinate system for all the data to integrate the complex tooth movement.Keywords: orthodontic treatment, tooth movement, stereovision system, long-term tracking
Procedia PDF Downloads 4217336 Comparative Study of Wear and Friction Behavior of Tricalcium Phosphate-Fluorapatite Bioceramic
Authors: Rym Taktak, Achwek Elghazel, Jamel Bouaziz
Abstract:
In the present work, we explored the potential of tribological behavior of tricalcium phosphate-Fluorapatite (β Tcp-Fap) bioceramic which has attracted considerable attention for orthopedics and dental applications. The approximate representatives Fap-βTcp were respectively [{13.26 wt%, 86.74 wt%} {19.9 wt%, 80.1 wt%},{ 26.52 wt%, 73.48 wt%}, {33.16 wt%, 66.84 wt%} and {40 wt%, 60 wt%}. The effects of Fluorapatite additives on friction and wear behavior were studied and discussed. The wear test was conducted using pion-disk tribometer at room temperature under dry condition using a constant sliding speed of 0,063 m/s, and three loads 3, 5 and 8 N. The wear rate and friction coefficient of β Tcp with different additive amounts were compared. An Alumina ball specimens were used as the pin and flat surface β Tcp-Fap specimens as the antagonist counterface. The results show a huge difference between the wear rate of β TCP samples and the other β TCP-Fap composites for all normal forces applied. This result shows the beneficial effect of fluorapatite on the tribological behavior of the β TCP. Moreover, we note that β Tcp-26% Fap specimens exhibit, under dry condition, the lower friction coefficient and the smaller wear rate than other biocomposites. Thereby, the friction and wear behavior is influenced by the addition of fluorapatite, the applied normal force, and the sliding velocity. To extend the understanding of the wear process, the surface topography of β Tcp-26% Fap specimens and the wear track obtained during the wear tests were studied using a surface profilometer, optical microscopy, and scanning electron microscopy.Keywords: alumina, bioceramic, friction and wear test, tricalcium phosphate
Procedia PDF Downloads 2347335 A Comparative Study of Active Release Technique and Myofascial Release Technique in Treatment of Patients with Upper Trapezius Spasm
Authors: Daxa Mishra, R. Harihara, Ankita
Abstract:
Trapezius muscle pain is the most common musculoskeletal disorder occurring in individuals who work with awkward positions, have repetitive movements and movements with precision demands. Treatment techniques like active release technique (ART) and myofascial release (MFR) can be used to relieve muscle spasm. The aim of the study is to compare the effect of ART and MFR on the upper trapezius muscle spasm. Methodology: A series of 60 patients of both sexes between the age group of 20 and 55 with upper trapezius spasm were divided into two groups by computerized randomization. Subjects in each group received treatment in the form of either ART or MFR for the period of seven days. cervical range of motion (ROM), neck disability index scale (NDI) and visual analog scale (VAS) tools were used to measure the outcome. Results: Paired Sample ‘t’ test was used to compare the Outcome differences within each group, while Independent ‘t’ test was used to compare the differences between the two groups for the same outcome measures. The improvement was found in both the groups at 7th day following intervention, but the group which received ART showed significant improvements as compared to group which received MFR. Conclusion: Although both techniques are effective in alleviation of symptoms and associated disability in upper trapezius muscle spasm, ART gave better results as compared to MRF.Keywords: goniometer, myofascial release, active release, physiotherapy
Procedia PDF Downloads 2447334 Comparison of Propofol versus Ketamine-Propofol Combination as an Anesthetic Agent in Supratentorial Tumors: A Randomized Controlled Study
Authors: Jakkireddy Sravani
Abstract:
Introduction: The maintenance of hemodynamic stability is of pivotal importance in supratentorial surgeries. Anesthesia for supratentorial tumors requires an understanding of localized or generalized rising ICP, regulation, and maintenance of intracerebral perfusion, and avoidance of secondary systemic ischemic insults. We aimed to compare the effects of the combination of ketamine and propofol with propofol alone when used as an induction and maintenance anesthetic agent during supratentorial tumors. Methodology: This prospective, randomized, double-blinded controlled study was conducted at AIIMS Raipur after obtaining the institute Ethics Committee approval (1212/IEC-AIIMSRPR/2022 dated 15/10/2022), CTRI/2023/01/049298 registration and written informed consent. Fifty-two supratentorial tumor patients posted for craniotomy and excision were included in the study. The patients were randomized into two groups. One group received a combination of ketamine and propofol, and the other group received propofol for induction and maintenance of anesthesia. Intraoperative hemodynamic stability and quality of brain relaxation were studied in both groups. Statistical analysis and technique: An MS Excel spreadsheet program was used to code and record the data. Data analysis was done using IBM Corp SPSS v23. The independent sample "t" test was applied for continuously dispersed data when two groups were compared, the chi-square test for categorical data, and the Wilcoxon test for not normally distributed data. Results: The patients were comparable in terms of demographic profile, duration of the surgery, and intraoperative input-output status. The trends in BIS over time were similar between the two groups (p-value = 1.00). Intraoperative hemodynamics (SBP, DBP, MAP) were better maintained in the ketamine and propofol combination group during induction and maintenance (p-value < 0.01). The quality of brain relaxation was comparable between the two groups (p-value = 0.364). Conclusion: Ketamine and propofol combination for the induction and maintenance of anesthesia was associated with superior hemodynamic stability, required fewer vasopressors during excision of supratentorial tumors, provided adequate brain relaxation, and some degree of neuroprotection compared to propofol alone.Keywords: supratentorial tumors, hemodynamic stability, brain relaxation, ketamine, propofol
Procedia PDF Downloads 257333 A Variational Reformulation for the Thermomechanically Coupled Behavior of Shape Memory Alloys
Authors: Elisa Boatti, Ulisse Stefanelli, Alessandro Reali, Ferdinando Auricchio
Abstract:
Thanks to their unusual properties, shape memory alloys (SMAs) are good candidates for advanced applications in a wide range of engineering fields, such as automotive, robotics, civil, biomedical, aerospace. In the last decades, the ever-growing interest for such materials has boosted several research studies aimed at modeling their complex nonlinear behavior in an effective and robust way. Since the constitutive response of SMAs is strongly thermomechanically coupled, the investigation of the non-isothermal evolution of the material must be taken into consideration. The present study considers an existing three-dimensional phenomenological model for SMAs, able to reproduce the main SMA properties while maintaining a simple user-friendly structure, and proposes a variational reformulation of the full non-isothermal version of the model. While the considered model has been thoroughly assessed in an isothermal setting, the proposed formulation allows to take into account the full nonisothermal problem. In particular, the reformulation is inspired to the GENERIC (General Equations for Non-Equilibrium Reversible-Irreversible Coupling) formalism, and is based on a generalized gradient flow of the total entropy, related to thermal and mechanical variables. Such phrasing of the model is new and allows for a discussion of the model from both a theoretical and a numerical point of view. Moreover, it directly implies the dissipativity of the flow. A semi-implicit time-discrete scheme is also presented for the fully coupled thermomechanical system, and is proven unconditionally stable and convergent. The correspondent algorithm is then implemented, under a space-homogeneous temperature field assumption, and tested under different conditions. The core of the algorithm is composed of a mechanical subproblem and a thermal subproblem. The iterative scheme is solved by a generalized Newton method. Numerous uniaxial and biaxial tests are reported to assess the performance of the model and algorithm, including variable imposed strain, strain rate, heat exchange properties, and external temperature. In particular, the heat exchange with the environment is the only source of rate-dependency in the model. The reported curves clearly display the interdependence between phase transformation strain and material temperature. The full thermomechanical coupling allows to reproduce the exothermic and endothermic effects during respectively forward and backward phase transformation. The numerical tests have thus demonstrated that the model can appropriately reproduce the coupled SMA behavior in different loading conditions and rates. Moreover, the algorithm has proved effective and robust. Further developments are being considered, such as the extension of the formulation to the finite-strain setting and the study of the boundary value problem.Keywords: generalized gradient flow, GENERIC formalism, shape memory alloys, thermomechanical coupling
Procedia PDF Downloads 2217332 Flexural Fatigue Performance of Self-Compacting Fibre Reinforced Concrete
Authors: Surinder Pal Singh, Sanjay Goel
Abstract:
The paper presents results of an investigation conducted to study the flexural fatigue characteristics of Self Compacting Concrete (SCC) and Self Compacting Fibre Reinforced Concrete (SCFRC). In total 360 flexural fatigue tests and 270 static flexural strength tests were conducted on SCC and SCFRC specimens to obtain the fatigue test data. The variability in the distribution of fatigue life of SCC and SCFRC have been analyzed and compared with that of NVC and NVFRC containing steel fibres of comparable size and shape. The experimental coefficients of fatigue equations have been estimated to represent relationship between stress level (S) and fatigue life (N) for SCC and SCFRC containing different fibre volume fractions. The probability of failure (Pf) has been incorporated in S-N relationships to obtain families of S-N-Pf relationships. A good agreement between the predicted curves and those obtained from the test data has been observed. The fatigue performance of SCC and SCFRC has been evaluated in terms of two-million cycles fatigue strength/endurance limit. The theoretic fatigue lives were also estimated using single-log fatigue equation for 10% probability of failure to estimate the enhanced extent of theoretic fatigue lives of SCFRC with reference to SCC and NVC. The reduction in variability in the fatigue life, increased endurance limit and increased theoretiac fatigue lives demonstrates an overall better fatigue performance for SCC and SCFRC.Keywords: fatigue life, fibre, probability of failure, self-compacting concrete
Procedia PDF Downloads 3587331 RAD-Seq Data Reveals Evidence of Local Adaptation between Upstream and Downstream Populations of Australian Glass Shrimp
Authors: Sharmeen Rahman, Daniel Schmidt, Jane Hughes
Abstract:
Paratya australiensis Kemp (Decapoda: Atyidae) is a widely distributed indigenous freshwater shrimp, highly abundant in eastern Australia. This species has been considered as a model stream organism to study genetics, dispersal, biology, behaviour and evolution in Atyids. Paratya has a filter feeding and scavenging habit which plays a significant role in the formation of lotic community structure. It has been shown to reduce periphyton and sediment from hard substrates of coastal streams and hence acts as a strongly-interacting ecosystem macroconsumer. Besides, Paratya is one of the major food sources for stream dwelling fishes. Paratya australiensis is a cryptic species complex consisting of 9 highly divergent mitochondrial DNA lineages. Among them, one lineage has been observed to favour upstream sites at higher altitudes, with cooler water temperatures. This study aims to identify local adaptation in upstream and downstream populations of this lineage in three streams in the Conondale Range, North-eastern Brisbane, Queensland, Australia. Two populations (up and down stream) from each stream have been chosen to test for local adaptation, and a parallel pattern of adaptation is expected across all streams. Six populations each consisting of 24 individuals were sequenced using the Restriction Site Associated DNA-seq (RAD-seq) technique. Genetic markers (SNPs) were developed using double digest RAD sequencing (ddRAD-seq). These were used for de novo assembly of Paratya genome. De novo assembly was done using the STACKs program and produced 56, 344 loci for 47 individuals from one stream. Among these individuals, 39 individuals shared 5819 loci, and these markers are being used to test for local adaptation using Fst outlier tests (Arlequin) and Bayesian analysis (BayeScan) between up and downstream populations. Fst outlier test detected 27 loci likely to be under selection and the Bayesian analysis also detected 27 loci as under selection. Among these 27 loci, 3 loci showed evidence of selection at a significance level using BayeScan program. On the other hand, up and downstream populations are strongly diverged at neutral loci with a Fst =0.37. Similar analysis will be done with all six populations to determine if there is a parallel pattern of adaptation across all streams. Furthermore, multi-locus among population covariance analysis will be done to identify potential markers under selection as well as to compare single locus versus multi-locus approaches for detecting local adaptation. Adaptive genes identified in this study can be used for future studies to design primers and test for adaptation in related crustacean species.Keywords: Paratya australiensis, rainforest streams, selection, single nucleotide polymorphism (SNPs)
Procedia PDF Downloads 2557330 Investigation of the NO2 Formation in the Exhaust Duct of a Dual Fuel Test Engine
Authors: Ehsan Arabian, Thomas Sattelmayer
Abstract:
The formation of nitrogen dioxide NO2 in the exhaust duct of a MAN dual fuel test engine has been investigated numerically. The dual fuel engine concept with premixed lean methane combustion ignited through diesel pilot flames reveals high potential for the abatement of the NOx formation. The drawback of this combustion method, however, is the high NO2 formation due to the increasing concentration of unburned hydrocarbons. This promotes the conversion of NO to NO2, which is toxic and characterized through its yellow color. The results presented in this paper cover a wide range of engine operation points from full load to part load for different air to fuel ratios. The effects of temperature, pressure and concentrations of unburned methane and nitric oxide on NO2 formation in the exhaust duct has been investigated on the basis of a zero-dimensional well stirred reactor model implemented in Cantera, which calculates the steady state of a uniform composition for a certain residence time. It can be shown that the simulated conversion of NO to NO2 match the experimental results fairly well. The partial oxidation of methane followed by CO production can be predicted as well. It can also be concluded that the lower temperature limit for which no conversion takes place, depends mainly on the concentration of the unburned hydrocarbons in the exhaust.Keywords: cantera, dual fuel engines, exhaust tract, numerical modeling of NO2 formation, well stirred reactor
Procedia PDF Downloads 2197329 An Adaptable Semi-Numerical Anisotropic Hyperelastic Model for the Simulation of High Pressure Forming
Authors: Daniel Tscharnuter, Eliza Truszkiewicz, Gerald Pinter
Abstract:
High-quality surfaces of plastic parts can be achieved in a very cost-effective manner using in-mold processes, where e.g. scratch resistant or high gloss polymer films are pre-formed and subsequently receive their support structure by injection molding. The pre-forming may be done by high-pressure forming. In this process, a polymer sheet is heated and subsequently formed into the mold by pressurized air. Due to the heat transfer to the cooled mold the polymer temperature drops below its glass transition temperature. This ensures that the deformed microstructure is retained after depressurizing, giving the sheet its final formed shape. The development of a forming process relies heavily on the experience of engineers and trial-and-error procedures. Repeated mold design and testing cycles are however both time- and cost-intensive. It is, therefore, desirable to study the process using reliable computer simulations. Through simulations, the construction of the mold and the effect of various process parameters, e.g. temperature levels, non-uniform heating or timing and magnitude of pressure, on the deformation of the polymer sheet can be analyzed. Detailed knowledge of the deformation is particularly important in the forming of polymer films with integrated electro-optical functions. Care must be taken in the placement of devices, sensors and electrical and optical paths, which are far more sensitive to deformation than the polymers. Reliable numerical prediction of the deformation of the polymer sheets requires sophisticated material models. Polymer films are often either transversely isotropic or orthotropic due to molecular orientations induced during manufacturing. The anisotropic behavior affects the resulting strain field in the deformed film. For example, parts of the same shape but different strain fields may be created by varying the orientation of the film with respect to the mold. The numerical simulation of the high-pressure forming of such films thus requires material models that can capture the nonlinear anisotropic mechanical behavior. There are numerous commercial polymer grades for the engineers to choose from when developing a new part. The effort required for comprehensive material characterization may be prohibitive, especially when several materials are candidates for a specific application. We, therefore, propose a class of models for compressible hyperelasticity, which may be determined from basic experimental data and which can capture key features of the mechanical response. Invariant-based hyperelastic models with a reduced number of invariants are formulated in a semi-numerical way, such that the models are determined from a single uniaxial tensile tests for isotropic materials, or two tensile tests in the principal directions for transversely isotropic or orthotropic materials. The simulation of the high pressure forming of an orthotropic polymer film is finally done using an orthotropic formulation of the hyperelastic model.Keywords: hyperelastic, anisotropic, polymer film, thermoforming
Procedia PDF Downloads 6177328 Study the Impact of Welding Poles Type on the Tensile Strength Steel of Low Alloys and High Resistance
Authors: Abdulmagid A. Khattabi, Abdul Fatah M. Emhamed
Abstract:
The steel alloy Introduced after becoming carbon-steel does not meet the requirements of engineering industry; and it cannot be obtained tensile strength from carbon-steel higher than (700MPa), the low alloy steel enters in a lot of heavy engineering equipment parts, molds, agricultural equipment and other industry. In addition, that may be exposed to in-service failure, which may require returned to work, to do the repairs or maintenance by one of the welding methods available. The ability of steel weld determined through palpation of the cracks, which can reduce by many ways. These ways are often expensive and difficult to implement, perhaps the control to choose the type of electrode welding user is one of the easiest and least expensive applications. It has been welding the steel low alloys high resistance by manual metal arc (MMA), and by using a set of welding electrodes which varying in chemical composition and in their prices as well and test their effect on tensile strength. Results showed that using the poles of welding, which have a high proportion of iron powder and low hydrogen. The Tensile resistance is (484MPa) and the weld joint efficiency was (56.9%), but when (OK 47.04) electrode was used the tensile strength increased to (720MPa) and the weld joint efficiency to (84.7%). Using the cheapest electrode (OK 45.00) the weld joint efficiency did not exceed (24.2%), but when using the most expensive electrode (OK 91.28) the weld joint efficiency is (38.1%).Keywords: steel low alloys high resistance, electrodes welding, tensile test
Procedia PDF Downloads 3197327 Complementary Mathematical Model for Underwater Vehicles under Load Variation Test Conditions
Authors: Erim Koyun
Abstract:
This paper aim to construct a mathematical model for Underwater vehicles under load variation test conditions. Propeller effects on underwater vehicle are investigated. Body with counter rotating propeller model is analyzed by CFD methods, thus forces and moment are obtained. Propeller effects of vehicle’s hydrodynamic performance under load variation conditions will be investigated. Additionally, pressure contour is examined for differences between different load conditions. Axial force equation is established using hydrodynamic coefficients, which contains resistance, thrust, and additional coefficients occurs due to load variations. Additional coefficients helps to express completely axial force on underwater vehicle. When the vehicle accelerates, additional force occurs besides thrust force increment. This is propeller effect on the body. Hence, mathematical model cover this effect. For CFD analysis, the incompressible, three-dimensional, and unsteady Reynolds Averaged Navier-Stokes equations will be used Numerical results is verified with experimental results for verification. The overall goal of this study is to present complementary mathematical model for body with counter rotating propeller.Keywords: counter rotating propeller, CFD, hydrodynamic mathematic model, hydrodynamics analysis, thrust deduction
Procedia PDF Downloads 1367326 Preparation and Cutting Performance of Boron-Doped Diamond Coating on Cemented Carbide Cutting Tools with High Cobalt Content
Authors: Zhaozhi Liu, Feng Xu, Junhua Xu, Xiaolong Tang, Ying Liu, Dunwen Zuo
Abstract:
Chemical vapor deposition (CVD) diamond coated cutting tool has excellent cutting performance, it is the most ideal tool for the processing of nonferrous metals and alloys, composites, nonmetallic materials and other difficult-to-machine materials efficiently and accurately. Depositing CVD diamond coating on the cemented carbide with high cobalt content can improve its toughness and strength, therefore, it is very important to research on the preparation technology and cutting properties of CVD diamond coated cemented carbide cutting tool with high cobalt content. The preparation technology of boron-doped diamond (BDD) coating has been studied and the coated drills were prepared. BDD coating were deposited on the drills by using the optimized parameters and the SEM results show that there are no cracks or collapses in the coating. Cutting tests with the prepared drills against the silumin and aluminum base printed circuit board (PCB) have been studied. The results show that the wear amount of the coated drill is small and the machined surface has a better precision. The coating does not come off during the test, which shows good adhesion and cutting performance of the drill.Keywords: cemented carbide with high cobalt content, CVD boron-doped diamond, cutting test, drill
Procedia PDF Downloads 4207325 Effectiveness of Peer Reproductive Health Education Program in Improving Knowledge, Attitude, and Use Health Service of High School Adolescent Girls in Eritrea in 2014
Authors: Ghidey Ghebreyohanes, Eltahir Awad Gasim Khalil, Zemenfes Tsighe, Faiza Ali
Abstract:
Background: reproductive health (RH) is a state of physical, mental and social well-being in all matters relating to the reproductive system at all stages of life. In East Africa including Eritrea, adolescents comprise more than a quarter of the population. The region holds the highest rates of sexually transmitted diseases, HIV, unwanted pregnancy and unsafe abortion with its complications. Young girls carry the highest burden of reproductive health problems due to their risk taking behavior, lack of knowledge, peer pressure, physiologic immaturity and low socioeconomic status. Design: this was a Community-based, randomized, case-controlled and pre-test-post-test intervention study. Setting: Zoba Debub was randomly selected out of the six zobas in Eritrea. The four high schools out of the 26 in Zoba Debub were randomly selected as study target schools. Over three quarter of the people live on farming. The target population was female students attending grade nine with majority of these girls live in the distant villages and walk to school. The study participants were randomly selected (n=165) from each school. Furthermore, the 1 intervention and 3 controls for the study arms were assigned randomly. Objectives: this study aimed to assess the effectiveness of peer reproductive health education in improving knowledge, attitude, and health service use of high school adolescent girls in Eritrea Methods: the protocol was reviewed and approved by the Scientific and Ethics Committees of Faculty of Nursing Sciences, University of Khartoum. Data was collected using pre-designed and pretested questionnaire emphasizing on reproductive health knowledge, attitude and practice. Sample size was calculated using proportion formula (α 0.01; power of 95%). Measures used were scores and proportions. Descriptive and inferential statistics, t-test and chi square at (α .01), 99% confidence interval were used to compare changes of pre and post-intervention scores using SPSS soft ware. Seventeen students were selected for peer educators by the school principals and other teachers based on inclusion criteria that include: good academic performance and acceptable behavior. One peer educator educated one group composed of 8-10 students for two months. One faculty member was selected to supervise peer educators. The principal investigator conducted the training of trainers and provided supervision and discussion to peer educators every two weeks until the end of intervention. Results: following informed consent, 627 students [164 in intervention and 463 in the control group] with a ratio of 1 to 3, were enrolled in the study. The mean age for the total study population was 15.4±1.0 years. The intervention group mean age was 15.3±1.0 year; while the control group had a mean age of 15.4±1.0. The mean ages for the study arms were similar (p= 0.4). The majority (96 %) of the study participants are from Tigrigna ethnic group. Reproductive knowledge scores which was calculated out of a total 61 grade points: intervention group (pretest 6.7 %, post-test 33.6 %; p= 0.0001); control group (pretest 7.3 %, posttest 7.3 %, p= 0.92). Proportion difference in attitude calculated out of 100%: intervention group (pretest 42.3 % post test 54.7% p= 0.001); controls group (pretest 45%, post test 44.8 p= 0.7). Proportion difference in Practice calculated out of 100 %: intervention group (pretest 15.4%, post test 80.4 % p= 0.0001); control group (pretest 16.8%, posttest 16.9 % p= 0.8). Mothers were quoted as major (> 90 %) source of reproductive health information. All focus group discussants and most of survey participants agreed on the urgent need of reproductive health information and services for adolescent girls. Conclusion: reproductive health knowledge and use of facilities is poor among adolescent girls in sub-urban Eretria. School-based peer reproductive health education is effective and is the best strategy to improve reproductive health knowledge and attitudes.Keywords: reproductive health, adolescent girls, eretria, health education
Procedia PDF Downloads 3627324 Formulation and In vivo Evaluation of Venlafaxine Hydrochloride Long Acting Tablet
Authors: Abdulwahhab Khedr, Tamer Shehata, Hanaa El-Ghamry
Abstract:
Venlafaxine HCl is a novel antidepressant drug used in the treatment of major depressive disorder, generalized anxiety disorder, social anxiety disorder and panic disorder. Conventional therapeutic regimens with venlafaxine HCl immediate-release dosage forms require frequent dosing due to short elimination half-life of the drug and reduced bioavailability. Hence, this study was carried out to develop sustained-release dosage forms of venlafaxine HCl to reduce its dosing frequency, to improve patient compliance and to reduce side effects of the drug. The polymers used were hydroxypropylmethyl cellulose, xanthan gum, sodium alginate, sodium carboxymethyl cellulose, Carbopol 940 and ethyl cellulose. The physical properties of the prepared tablets including tablet thickness, diameter, weight uniformity, content uniformity, hardness and friability were evaluated. Also, the in-vitro release of venlafaxine HCl from different matrix tablets was studied. Based on physical characters and in-vitro release profiles, certain formulae showing promising sustained-release profiles were subjected to film coating with 15% w/v EC in dichloromethane/ethanol mixture (1:1 ratio) using 1% w/v HPMC as pore former and 30% w/w dibutyl phthalate as plasticizer. The optimized formulations were investigated for drug-excipient compatibility using FTIR and DSC studies. Physical evaluation of the prepared tablets fulfilled the pharmacopoeial requirements for tablet friability test, where the weight loss of the prepared formulae did not exceed 1% of the weight of the tested tablets. Moderate release was obtained from tablets containing HPMC. FTIR and DSC studies for such formulae revealed the absence of any type of chemical interaction between venlafaxine HCl and the used polymers or excipients. Forced swimming test in rats was used to evaluate the antidepressant activity of the selected matrix tablets of venlafaxine HCl. Results showed that formulations significantly decreased the duration of animals’ immobility during the 24 hr-period of the test compared to non-treated group.Keywords: antidepressant, sustained-release, matrix tablet, venlafaxine hydrochloride
Procedia PDF Downloads 2407323 Application of Enzyme-Mediated Calcite Precipitation for Surface Control of Gold Mining Tailing Waste
Authors: Yogi Priyo Pradana, Heriansyah Putra, Regina Aprilia Zulfikar, Maulana Rafiq Ramadhan, Devyan Meisnnehr, Zalfa Maulida Insani
Abstract:
This paper studied the effects and mechanisms of fine-grained tailing by Enzyme-Mediated Calcite Precipitation (EMCP). Grouting solution used consists of reagents (CaCl₂ and (CO(NH₂)₂) and urease enzymes which react to produce CaCO₃. In sample preparation, the test tube is used to investigate the precipitation rate of calcite. The grouting solution added is 75 mL for one mold sample. The solution was poured into a mold sample up to as high as 5 mm from the top surface of the tailing to ensure the entire surface is submerged. The sample is left open in a cylinder for up to 3 days for curing. The direct mixing method is conducted so that the cementation process occurs by evenly distributed. The relationship between the results of the UCS test and the calcite precipitation rate likely indicates that the amount of calcite deposited in treated tailing could control the strength of the tailing. The sample results are analyzed using atomic absorption spectroscopy (AAS) to evaluate metal and metalloid content. Calcium carbonate deposited in the tailing is expected to strengthen the bond between tailing granules, which are easily slipped on the banks of the tailing dam. The EMCP method is expected to strengthen tailing in erosion-control surfaces.Keywords: tailing, EMCP, UCS, AAS
Procedia PDF Downloads 1387322 Corrosion Mitigation in Gas Facilities Piping Through the Use of FBE Coated Pipes and Corrosion Resistant Alloy Girth Welds
Authors: Fadi Chammas, Saad Alkhaldi, Tariq Alghamdi, Stefano Alexandirs
Abstract:
The operating conditions and corrosive nature of the process fluid in the Haradh and Hawiyah areas are subjecting facility piping to undesirable corrosion phenomena. Therefore, production headers inside remote headers have been internally cladded with high alloy material to mitigate the corrosion damage mechanism. Corrosion mitigation in the jump-over lines, constructed between the existing flowlines and the newly constructed facilities to provide operational flexibility, is proposed. This corrosion mitigation system includes the application of fusion bond epoxy (FBE) coating on the internal surface of the pipe and depositing corrosion-resistant alloy (CRA) weld layers at pipe and fittings ends to protect the carbon steel material. In addition, high alloy CRA weld material is used to deposit the girth weld between the 90-degree elbows and mating internally coated segments. A rigorous testing and qualification protocol was established prior to actual adoption at the Haradh and Hawiyah Field Gas Compression Program, currently being executed by Saudi Aramco. The proposed mitigation system, aimed at applying the cladding at the ends of the internally FBE coated pipes/elbows, will resolve field joint coating challenges, eliminate the use of approximately (1700) breakout flanges, and prevent the potential hydrocarbon leaks.Keywords: pipelines, corrosion, cost-saving, project completion
Procedia PDF Downloads 1237321 Impact of an Educational Intervention on Knowledge, Attitude and Practices of Community Members on Schistosomiasis in Nelson Mandela Bay
Authors: Prince S. Campbell, Janine B. Adams, Melusi Thwala, Opeoluwa Oyedele, Paula E. Melariri
Abstract:
Schistosomiasis, often known as bilharzia, is a parasitic water-borne disease caused by trematode flatworms of the genus Schistosoma. Schistosomiasis infection and prevention have been found to be influenced by a range of socio-cultural risk factors, including human characteristics (e.g., gender, age, education, knowledge, attitude, and practices), as well as environmental and economic elements. Lack of awareness of the disease may also contribute to an individual's tendency to participate in behaviours or activities that heighten their susceptibility to infection. The current study assessed the community knowledge, attitude and practices (KAP) on schistosomiasis and implemented an educational intervention following pre-test interviews. A cross-sectional quasi-experimental research design was used in this quantitative study. Pre- and post-intervention interview format surveys were conducted using a structured questionnaire, targeting individuals aged 18–65 years residing within 5 km of select water bodies. The questionnaire contained 54 close-ended questions about schistosomiasis causes, transmission, and clinical symptoms and the participants were interviewed face-to-face in their homes. Data was captured on Question Pro and analyzed using Microsoft Office Excel 365 (2019) and R (version 4.3.1) software. Overall, 380 individuals completed the pre and post-intervention assessments; 194 and 185 were males (51.1%) and females (48.7%), respectively. A notable 91.3% of participants did not know about schistosomiasis in the pre-intervention phase; however, the mean post-intervention test score (9.4 ± 1.4) for knowledge among participants was higher than the pre-intervention test score (2.2 ± 2.1) indicating a good and improved knowledge of schistosomiasis among the participants. Furthermore, the paired samples t-test results demonstrated that the increase in knowledge levels was statistically significant (p<0.001). Also, the post-intervention improvement of both practice (p<0.001) and attitude (p<0.001) levels was statistically significant. A positive correlation (r=0.23, p<0.001) was found between knowledge and attitude in the pre-intervention stage. Knowledgeable participants had a more positive attitude towards obtaining medical assistance and disease prevention. Moreover, attitudes and practices correlated negatively (r=-0.13, p=0.013) post-intervention; hence, those with positive attitudes did not engage in risky water-related practices, which was the desired outcome. The educational intervention had a favourable impact on the KAP of the study population as the majority were able to recall the disease aetiology, symptoms, transmission pattern, and preventative measures three months post-intervention. Nevertheless, previous research has suggested that participants were unable to recall information about the disease following the intervention. Consequently, research should prioritize behavioural modification strategies that may result in a more persistent outcome in terms of the participants' knowledge, which could ultimately contribute to the development of long-term positive attitudes and practices.Keywords: educational intervention, knowledge, attitudes and practices, schistosomiasis
Procedia PDF Downloads 18