Search results for: insulation cork board
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1072

Search results for: insulation cork board

892 Revisiting Corporate Social Responsibility in the Lens of Board Accountability

Authors: Jingchen Zhao

Abstract:

Corporate social responsibility (CSR), a major contemporary focus for companies, governments, NGOs and communities, is discussed from a multi-disciplinary perspective. The term is introduced and defined to achieve a combination of economic, social, environmental and philanthropic goals, and its adoption in company law legislations in a few jurisdictions is discussed. Despite its positive social and environmental impacts, the notion has been widely criticised for being ill-defined and fundamentally flawed in the domain of corporate law. The value and effectiveness of CSR have been interrogated for many reasons, always inter-related. This article aims to consider and address some of these problems and assess how CSR could be sharpened and made more effective through the lens of accountability, focussing on the rationale behind and the means of regulation of CSR. The article aims to achieve two interrelated goals. First, it examines the function of accountability in the arguments in favour of CSR by investigating the extent to which the notion of accountability could be used as a criterion for regulating CSR, so that companies may be held accountable for corporate decisions affecting their stakeholders. Second, this article will examine the scope and goals of CSR and board accountability, creating the possibility of a more comprehensive understanding of the two notions from an interactive perspective. In order to link CSR and accountability closely to generate a more appropriate definition of CSR that is could be more appropriately and effectively applied in corporate law, the concept of corporate social accountability (CSA) will be evaluated, with the aim of broadening its latitude beyond disclosure. This will involve a rigorous assessment of the process of fulfilling directors’ duties via questioning from stakeholder groups during meetings or committees, together with explanations and justifications from the board. This will be followed by discussions on enforcement measures in relation to the concept of CSA.

Keywords: corporate governance, CSR, board accountability, corporate law

Procedia PDF Downloads 286
891 Corporate Governance and Firms` Performance: Evidence from Quoted Firms on the Nigerian Stock Exchange

Authors: Ogunwole Cecilia Oluwakemi, Wahid Damilola Olanipekun, Omoyele Olufemi Samuel, Timothy Ayomitunde Aderemi

Abstract:

The issues relating to corporate governance in both locally and internationally managed firms cannot be overemphasized because the lack of efficient corporate governance could orchestrate serious problems in any organization. Against this backdrop, this study examines the nexus between corporate governance and performance of firms from 2012 to 2020, using the case study of the Nigerian stock exchange. Consequently, data was collected from forty (40) listed firms on the Nigerian Stock Exchange. The study employed a fixed effect technique of estimation to address the objective of the study. It was discovered from the study that the influence of corporate governance components such as gender diversity, board independence and managerial ownership led to a significant positive impact on the performance of the firms under the investigation. In view of the above finding, this study makes the following recommendations for the policymakers in Nigeria that anytime the goal of the policymakers is the improvement of performance of the listed firms in the Nigerian stock exchange, board independence and a balance in the inclusion of male and female among the board of directors should be encouraged in these firms.

Keywords: corporate, governance, firms, performance, Nigeria, stock, exchange

Procedia PDF Downloads 137
890 Production of Friendly Environmental Material as Building Element from Plastic Waste

Authors: Dheyaa Wajid Abbood, Mohanad Salih Farhan, Awadh E. Ajeel

Abstract:

The basic goal of this study is the production of cheap building elements from plastic waste. environmentally friendly and of good thermal insulation. The study depends on the addition of plastic waste as aggregates to the mixes of concrete at different percentages by weight (12 percentages) to produce lightweight aggregate concrete the density (1095 - 1892) kg/m3.The experimental work includes 120 specimens of concrete 72 cubes (150*150*150)mm, 48 cylinder (150*300) mm. The results obtained for concrete were for local raw materials without any additional materials or treatment. The mechanical and thermal properties determined were (compressive strength, static modulus of elasticity, density, thermal conductivity (k), specific heat capacity (Cp), thermal expansion (α) after (7) days of curing at 20 0C. The increase in amount of plastic waste decreases the density of concrete which leads to decrease in the mechanical and to improvement in thermal properties. The average measured static modulus of elasticity are found less than the predicted static modulus of elasticity and splitting tensile strength (ACI 318-2008 and ACI 213R-2003). All cubes specimens when exposed to heat at (200, 400, 600 0C), the compressive strength of all mixes decreases gradually at 600 0C, the strength of lightweight aggregate concrete were disintegrated. Lightweight aggregate concrete is about 25% lighter than normal concrete in dead load, and to the improve the properties of thermal insulation of building blocks.

Keywords: LWAC, plastic waste, thermal property, thermal insulation

Procedia PDF Downloads 400
889 Mechanical and Physical Properties of Wood Composite Panel from Recycled Plastic and Sawdust of Cordia alliodora (Ruiz and Pav.)

Authors: Ahmed Bolaji Alarape, Oluwatobi Damilola Aba, Usman Shehu

Abstract:

Wood plastic composite boards were made from sawn dust of Cordia alliodora and recycled polyethylene at a mixing ratio of 1.5ratio1, 2.5ratio1 and 3.5ratio1 and nominal densities of 600 kilograms per meter cube, 700 kilograms per meter cube, and 800 kilograms per meter cube, The material was hot pressed at 150-degree celsius to produce board of 250 millimeter by 250 millimeter by 6 millimeter of which 18 boards were produced. The experiment was subject to 3 by 3 factorial experiments in Completely Randomised Design (CRD). Analysis of variance and Duncan Multiple Range Test (DMRT) was adopted by 3 by 3 at 5 percent probability. The strength properties of the boards such as modulus of rupture (MOR) and modulus of elasticity (MOE) were investigated, while the dimensional properties of the board such as the water absorption (WA) and thickness swelling (TS) were as well determined after 12hrs and 24hrs of water immersion. The result showed that the mean values of MOE ranged from 9100.73 Newtons per square millimeters to 12086.96 Newtons per square millimeters while MOR values ranged from 48.26 Newtons per square millimeters to 103.09 Newtons per square millimeters. The values of WA and TS after 12hrs immersion ranged from 1.21 percent to 1.56 percent and 0.00 percent to 0.13 percent, respectively. The values of WA and TS after 24hrs of water immersion ranged from 1.66 percent to 2.99 percent and 0.02 percent to 0.18 percent, respectively. The higher the value of board density and the high-density polythene /sawdust ratio, the stronger, the stiffer and more dimensionally stable the wood plastic composite boards obtained. In addition, as the density of the board increases, the strength property of the boards increases. Hence the board will be suitable for internal construction materials.

Keywords: wood Plastic composite, modulus of rupture, modulus of elasticity, dimensional stability

Procedia PDF Downloads 153
888 The On-Board Critical Message Transmission Design for Navigation Satellite Delay/Disruption Tolerant Network

Authors: Ji-yang Yu, Dan Huang, Guo-ping Feng, Xin Li, Lu-yuan Wang

Abstract:

The navigation satellite network, especially the Beidou MEO Constellation, can relay data effectively with wide coverage and is applied in navigation, detection, and position widely. But the constellation has not been completed, and the amount of satellites on-board is not enough to cover the earth, which makes the data-relay disrupted or delayed in the transition process. The data-relay function needs to tolerant the delay or disruption in some extension, which make the Beidou MEO Constellation a delay/disruption-tolerant network (DTN). The traditional DTN designs mainly employ the relay table as the basic of data path schedule computing. But in practical application, especially in critical condition, such as the war-time or the infliction heavy losses on the constellation, parts of the nodes may become invalid, then the traditional DTN design could be useless. Furthermore, when transmitting the critical message in the navigation system, the maximum priority strategy is used, but the nodes still inquiry the relay table to design the path, which makes the delay more than minutes. Under this circumstances, it needs a function which could compute the optimum data path on-board in real-time according to the constellation states. The on-board critical message transmission design for navigation satellite delay/disruption-tolerant network (DTN) is proposed, according to the characteristics of navigation satellite network. With the real-time computation of parameters in the network link, the least-delay transition path is deduced to retransmit the critical message in urgent conditions. First, the DTN model for constellation is established based on the time-varying matrix (TVM) instead of the time-varying graph (TVG); then, the least transition delay data path is deduced with the parameters of the current node; at last, the critical message transits to the next best node. For the on-board real-time computing, the time delay and misjudges of constellation states in ground stations are eliminated, and the residual information channel for each node can be used flexibly. Compare with the minute’s delay of traditional DTN; the proposed transmits the critical message in seconds, which improves the re-transition efficiency. The hardware is implemented in FPGA based on the proposed model, and the tests prove the validity.

Keywords: critical message, DTN, navigation satellite, on-board, real-time

Procedia PDF Downloads 321
887 Buildings Founded on Thermal Insulation Layer Subjected to Earthquake Load

Authors: David Koren, Vojko Kilar

Abstract:

The modern energy-efficient houses are often founded on a thermal insulation (TI) layer placed under the building’s RC foundation slab. The purpose of the paper is to identify the potential problems of the buildings founded on TI layer from the seismic point of view. The two main goals of the study were to assess the seismic behavior of such buildings, and to search for the critical structural parameters affecting the response of the superstructure as well as of the extruded polystyrene (XPS) layer. As a test building a multi-storeyed RC frame structure with and without the XPS layer under the foundation slab has been investigated utilizing nonlinear dynamic (time-history) and static (pushover) analyses. The structural response has been investigated with reference to the following performance parameters: i) Building’s lateral roof displacements, ii) Edge compressive and shear strains of the XPS, iii) Horizontal accelerations of the superstructure, iv) Plastic hinge patterns of the superstructure, v) Part of the foundation in compression, and vi) Deformations of the underlying soil and vertical displacements of the foundation slab (i.e. identifying the potential uplift). The results have shown that in the case of higher and stiff structures lying on firm soil the use of XPS under the foundation slab might induce amplified structural peak responses compared to the building models without XPS under the foundation slab. The analysis has revealed that the superstructure as well as the XPS response is substantially affected by the stiffness of the foundation slab.

Keywords: extruded polystyrene (XPS), foundation on thermal insulation, energy-efficient buildings, nonlinear seismic analysis, seismic response, soil–structure interaction

Procedia PDF Downloads 279
886 Material Concepts and Processing Methods for Electrical Insulation

Authors: R. Sekula

Abstract:

Epoxy composites are broadly used as an electrical insulation for the high voltage applications since only such materials can fulfill particular mechanical, thermal, and dielectric requirements. However, properties of the final product are strongly dependent on proper manufacturing process with minimized material failures, as too large shrinkage, voids and cracks. Therefore, application of proper materials (epoxy, hardener, and filler) and process parameters (mold temperature, filling time, filling velocity, initial temperature of internal parts, gelation time), as well as design and geometric parameters are essential features for final quality of the produced components. In this paper, an approach for three-dimensional modeling of all molding stages, namely filling, curing and post-curing is presented. The reactive molding simulation tool is based on a commercial CFD package, and include dedicated models describing viscosity and reaction kinetics that have been successfully implemented to simulate the reactive nature of the system with exothermic effect. Also a dedicated simulation procedure for stress and shrinkage calculations, as well as simulation results are presented in the paper. Second part of the paper is dedicated to recent developments on formulations of functional composites for electrical insulation applications, focusing on thermally conductive materials. Concepts based on filler modifications for epoxy electrical composites have been presented, including the results of the obtained properties. Finally, having in mind tough environmental regulations, in addition to current process and design aspects, an approach for product re-design has been presented focusing on replacement of epoxy material with the thermoplastic one. Such “design-for-recycling” method is one of new directions associated with development of new material and processing concepts of electrical products and brings a lot of additional research challenges. For that, one of the successful products has been presented to illustrate the presented methodology.

Keywords: curing, epoxy insulation, numerical simulations, recycling

Procedia PDF Downloads 258
885 Adapting the Chemical Reaction Optimization Algorithm to the Printed Circuit Board Drilling Problem

Authors: Taisir Eldos, Aws Kanan, Waleed Nazih, Ahmad Khatatbih

Abstract:

Chemical Reaction Optimization (CRO) is an optimization metaheuristic inspired by the nature of chemical reactions as a natural process of transforming the substances from unstable to stable states. Starting with some unstable molecules with excessive energy, a sequence of interactions takes the set to a state of minimum energy. Researchers reported successful application of the algorithm in solving some engineering problems, like the quadratic assignment problem, with superior performance when compared with other optimization algorithms. We adapted this optimization algorithm to the Printed Circuit Board Drilling Problem (PCBDP) towards reducing the drilling time and hence improving the PCB manufacturing throughput. Although the PCBDP can be viewed as instance of the popular Traveling Salesman Problem (TSP), it has some characteristics that would require special attention to the transactions that explore the solution landscape. Experimental test results using the standard CROToolBox are not promising for practically sized problems, while it could find optimal solutions for artificial problems and small benchmarks as a proof of concept.

Keywords: evolutionary algorithms, chemical reaction optimization, traveling salesman, board drilling

Procedia PDF Downloads 496
884 UK GAAP and IFRS Standards: Similarities and Differences

Authors: Feddaoui Amina

Abstract:

This paper aimed to help researchers and international companies to the differences and similarities between IFRS (International financial reporting standards) and UK GAAP or UK accounting principles, and to the accounting changes between standard setting of the International Accounting Standards Board and the Accounting Standards Board in United Kingdom. We will use in this study statistical methods to calculate similarities and difference frequencies between the UK standards and IFRS standards, according to the PricewaterhouseCoopers report in 2005. We will use the one simple test to confirm or refuse our hypothesis. In conclusion, we found that the gap between UK GAAP and IFRS is small.

Keywords: accounting, UK GAAP, IFRS, similarities, differences

Procedia PDF Downloads 196
883 The Investigation of Cracking on the Shell of Dryers (tag No. 2DR-1745 and DR-1402) in Shahid Tondguyan Petrochemical Company (STPC)

Authors: Ali Haghiri

Abstract:

This research has been to investigate the cause of the stress corrosion cracking on dryer equipment (2DR-1745 and DR-1402) in Shahid Tondguyan Petrochemical Company (STPC). These dryers are as a drying powder Terphetalic acid in CTA2 and CTA1 unit. After passing through RVF equipment, wet cake moisture content of about 14% and temperature of 90C changed into a dry cake with a moisture content of less than 0.1% and the final temperature of about 140C and sent out Final Silo (FS-1820). After the declaration of the operation department concerning the observation of acid leakage under the primary insulation was decided that at the first opportunity, this issue must be investigated. So, after the shutdown of a unit at the date 2012/10/20 (2DR-1745) and 2021/11/24 (DR-1402) and after washing the dryer wall, insulation around the wall opened and it was found to crack and leakage from some points.

Keywords: stress corrosion cracking, residual stress, austenitic stainless steel, Br- ion

Procedia PDF Downloads 140
882 Study of the Physical Aging of Polyvinyl Chloride (PVC)

Authors: Mohamed Ouazene

Abstract:

The insulating properties of the polymers are widely used in electrical engineering for the production of insulators and various supports, as well as for the insulation of electric cables for medium and high voltage, etc. These polymeric materials have significant advantages both technically and economically. However, although the insulation with polymeric materials has advantages, there are also certain disadvantages such as the influence of the heat which can have a detrimental effect on these materials. Polyvinyl chloride (PVC) is one of the polymers used in a plasticized state in the cable insulation to medium and high voltage. The studied material is polyvinyl chloride (PVC 4000 M) from the Algerian national oil company whose formula is: Industrial PVC 4000 M is in the form of white powder. The test sample is a pastille of 1 mm thick and 1 cm in diameter. The consequences of increasing the temperature of a polymer are modifications; some of them are reversible and others irreversible [1]. The reversible changes do not affect the chemical composition of the polymer, or its structure. They are characterized by transitions and relaxations. The glass transition temperature is an important feature of a polymer. Physical aging of PVC is to maintain the material for a longer or shorter time to its glass transition temperature. The aim of this paper is to study this phenomenon by the method of thermally stimulated depolarization currents. Relaxations within the polymer have been recorded in the form of current peaks. We have found that the intensity decreases for more residence time in the polymer along its glass transition temperature. Furthermore, it is inferred from this work that the phenomenon of physical aging can have important consequences on the properties of the polymer. It leads to a more compact rearrangement of the material and a reconstruction or reinforcement of structural connections.

Keywords: depolarization currents, glass transition temperature, physical aging, polyvinyl chloride (PVC)

Procedia PDF Downloads 368
881 Analysis of Sound Loss from the Highway Traffic through Lightweight Insulating Concrete Walls and Artificial Neural Network Modeling of Sound Transmission

Authors: Mustafa Tosun, Kevser Dincer

Abstract:

In this study, analysis on whether the lightweight concrete walled structures used in four climatic regions of Turkey are also capable of insulating sound was conducted. As a new approach, first the wall’s thermal insulation sufficiency’s were calculated and then, artificial neural network (ANN) modeling was used on their cross sections to check if they are sound transmitters too. The ANN was trained and tested by using MATLAB toolbox on a personal computer. ANN input parameters that used were thickness of lightweight concrete wall, frequency and density of lightweight concrete wall, while the transmitted sound was the output parameter. When the results of the TS analysis and those of ANN modeling are evaluated together, it is found from this study, that sound transmit loss increases at higher frequencies, higher wall densities and with larger wall cross sections.

Keywords: artificial neuron network, lightweight concrete, sound insulation, sound transmit loss

Procedia PDF Downloads 230
880 Voxel Models as Input for Heat Transfer Simulations with Siemens NX Based on X-Ray Microtomography Images of Random Fibre Reinforced Composites

Authors: Steven Latré, Frederik Desplentere, Ilya Straumit, Stepan V. Lomov

Abstract:

A method is proposed in order to create a three-dimensional finite element model representing fibre reinforced insulation materials for the simulation software Siemens NX. VoxTex software, a tool for quantification of µCT images of fibrous materials, is used for the transformation of microtomography images of random fibre reinforced composites into finite element models. An automatic tool was developed to execute the import of the models to the thermal solver module of Siemens NX. The paper describes the numerical tools used for the image quantification and the transformation and illustrates them on several thermal simulations of fibre reinforced insulation blankets filled with low thermal conductive fillers. The calculation of thermal conductivity is validated by comparison with the experimental data.

Keywords: analysis, modelling, thermal, voxel

Procedia PDF Downloads 272
879 Thermal Behavior of Green Roof: Case Study at Seoul National University Retentive Green Roof

Authors: Theresia Gita Hapsari

Abstract:

There has been major concern about urban heating as urban clusters emerge and population migration from rural to urban areas continues. Green roof has been one of the main practice for urban heat island mitigation for the past decades, thus, this study was conducted to predict the cooling potential of retentive green roof in mitigating urban heat island. Retentive green roof was developed by Han in 2010. It has 320 mm height of retention wall surrounding the vegetation and 65mm depth of retention board underneath the soil, while most conventional green roof doesn’t have any retention wall and only maximum of 25 mm depth of drainage board. Seoul National University retentive green roof significantly reduced sensible heat movement towards the air by 0.5 kWh/m2, and highly enhanced the evaporation process as much as 0.5 – 5.4 kg/m2 which equals to 0.3 – 3.6 kWh/m2 of latent heat flux. These results indicate that with design enhancement, serving as a viable alternate for conventional green roof, retentive green roof contributes to overcome the limitation of conventional green roof which is the main solution for mitigating urban heat island.

Keywords: green roof, low impact development, retention board, thermal behavior, urban heat island

Procedia PDF Downloads 261
878 Corporate Governance and Audit Report Lag: The Case of Tunisian Listed Companies

Authors: Lajmi Azhaar, Yab Mdallelah

Abstract:

This study examines the Tunisian market in which recent events, notably financial scandals, provide an appropriate framework for studying the impact of corporate governance on the audit report lag. Moreover, very little research has been done to examine this relationship in this context. The objective of this work is, therefore, to understand the factors influencing audit report lag, drawing primarily on agency theory (Jensen and Meckling, 1976), which shows that the characteristics of the board of directors have an impact on the report lag (independence, diligence, and size). In addition, the characteristics of the committee also have an impact on the audit report lag (size, independence, diligence, and expertise). Therefore, our research provides empirical evidence on the impact of governance mechanisms attributes on audit report lag. Using a sample of forty-seven (47) Tunisian companies listed on the Tunis Stock Exchange (BVMT) during the period from 2014 to 2019, and basing on the GMM method of the dynamic panel, multivariate analysis shows that most corporate governance attributes have a significant effect on audit report lag. Specifically, the audit committee diligence and the audit committee expertise have a significant and positive effect on audit report lag. But the diligence of the board has a significant and negative effect on audit report lag. However, this study finds no evidence that the audit committee independence, the size, independence, and diligence of the director’s board are associated with the audit report lag. In addition, the results of this study also show that there is a significant effect of some control variables. Finally, we are contributing to this study by using the GMM method of the dynamic panel. We are also using an emerging context that is very poorly developed and exploited by previous studies.

Keywords: governance mechanisms, audit committee, board of directors, audit report lag

Procedia PDF Downloads 142
877 A Comparison between Modelled and Actual Thermal Performance of Load Bearing Rammed Earth Walls in Egypt

Authors: H. Hafez, A. Mekkawy, R. Rostom

Abstract:

Around 10% of the world’s CO₂ emissions could be attributed to the operational energy of buildings; that is why more research is directed towards the use of rammed earth walls which is claimed to have enhanced thermal properties compared to conventional building materials. The objective of this paper is to outline how the thermal performance of rammed earth walls compares to conventional reinforced concrete skeleton and red brick in-fill walls. For this sake, the indoor temperature and relative humidity of a classroom built with rammed earth walls and a vaulted red brick roof in the area of Behbeit, Giza, Egypt were measured hourly over 6 months using smart sensors. These parameters for the rammed earth walls were later also compared against the values obtained using a 'DesignBuilder v5' model to verify the model assumptions. The thermal insulation of rammed earth walls was found to be 30% better than this of the redbrick infill, and the recorded data were found to be almost 90% similar to the modelled values.

Keywords: rammed earth, thermal insulation, indoor air quality, design builder

Procedia PDF Downloads 130
876 Energy Certification Labels and Comfort Assessment for Dwellings Located in a Mild Climate

Authors: Silvia A. Magalhaes, Vasco P. De Freitas, Jose L. Alexandre

Abstract:

Most of the European literature concerning energy efficiency and thermal comfort of dwellings assumes permanent heating and focuses on energy-saving measures. European National regulations are designed for those permanent comfort conditions. On the other hand, very few studies focus on the effect of the improvement measures in comfort reduction, for free-floating conditions or intermittent heating, in fuel poverty vulnerable countries. In Portugal, only 21% of the household energy consumptions (and 10% of the cost) are spent in space heating, while, on average European bills, this value rises to 67%. The mild climate, but mainly fuel poverty and cultural background, justifies these low heating practices. This study proposes a “passive discomfort” index definition, considering free-floating temperatures or with intermittent heating profiles (more realistic conditions), putting the focus on comfort rather than energy consumption (which is low for these countries). The aim is to compare both energy (regarding the legal framework of national regulation) and comfort (considering realistic conditions of use) to identify some correlation. It was developed an experimental campaign of indoor thermal conditions in a 19th building located in Porto with several apartments. One dwelling was chosen as a case study to carry out a sensitivity analysis. The results are discussed comparing both theoretical energy consumption (energy rates from national regulation) and discomfort (new index defined), for different insulation thicknesses, orientations, and intermittent heating profiles. The results show that the different passive options (walls insulation and glazing options) have a small impact on winter discomfort, which is always high for low heating profiles. Moreover, it was shown that the insulation thickness on walls has no influence, and the minimum insulation thickness considered is enough to achieve the same impact on discomfort reduction. Plus, for these low heating profiles, other conditions are critical, as the orientation. Finally, there isn’t an unequivocal relation between the energy label and the discomfort index. These and other results are surprising when compared with the most usual approaches, which assume permanent heating.

Keywords: dwellings in historical buildings, low-heating countries, mild climates, thermal comfort

Procedia PDF Downloads 115
875 Performance Investigation of Thermal Insulation Materials for Walls: A Case Study in Nicosia (Turkish Republic of North Cyprus)

Authors: L. Vafaei, McDominic Eze

Abstract:

The performance of thermal energy in homes and buildings is a significant factor in terms of energy efficiency of a building. In a large sense, the performance of thermal energy is dependent on many factors of which the amount of thermal insulation is at one end a considerable factor, as likewise the essence of mass and the wall thickness and also the thermal resistance of wall material. This study is aimed at illustrating the different wall system in Turkish Republic of North Cyprus (TRNC), acknowledge the problem and suggest a solution through comparing the effect of thermal radiation two model rooms- L1 (Ytong wall) and L2 (heat insulated wall using stone wool) set up for experimentation. The model room has four face walls. The study consists of two stage, the first test is to access the effect of solar radiation for south facing wall and the second stage is to test the thermal performance of Ytong and heat insulated wall, the effects of climatic condition during winter. The heat insulated wall contains material hollow brick, stone wool, and gypsum while the Ytong wall contains cement concrete, for the outer surface and the inner surface and Ytong stone. The total heat of the wall was determined, 7T-Type thermocouple was used with a data logger system to record the data, temperature change recorded at an interval of 10 minutes. The result obtained was that Ytong wall save more energy than the heat insulated wall at night while heat insulated wall saves energy during the day when intensity is at maximum.

Keywords: heat insulation, hollow bricks, south facing, Ytong bricks wall

Procedia PDF Downloads 246
874 Live and Learn in Ireland: Supporting International Students

Authors: Tom Farrelly, Yvoonne Kavanagh, Tony Murphy

Abstract:

In the last 20 years, Ireland has enjoyed an upsurge in the number of international students coming to avail of its well-regarded Higher Education system. While welcome, the influx of international students has posed a number of cultural, social and academic challenges for the Irish HE sector, both at institutional and individual lecturer level. Notwithstanding the challenge to the Irish HE sector, the difficulties that incoming students face needs to be acknowledged and addressed. For students who have never left their home country before the transition can be daunting even if they have not learned the customs and ways of the new country. In 2013, Ireland’s National Forum for the Advancement of Teaching and Learning in Higher Education invited submissions from interested parties to design and implement digital supports aimed at assisting students transitioning into or exiting higher education. Five colleges—the Institute of Technology, Tralee; University College Cork, Institute of Technology, Carlow; Cork Institute of Technology and Waterford Institute of Technology—collectively known as the Southern Cluster, were granted funding to research and develop digital objects to support international students' transition into the Irish higher education system. One of the key fundamentals of this project was its strong commitment to incorporating the student voice to help inform the design of the digital objects. The primary research method used to ascertain student views was the circulation of an online questionnaire using SurveyMonkey to existing international students in each of the five participant colleges. The questionnaire sought to examine the experiences and opinions of the students in relation to three main aspects of their living and studying in Ireland (hence the name of the project LiveAndLearnInIreland) (1) the academic environment (2) the social aspects of living in Ireland and (3) the practical aspects of living in Ireland. The response to the survey (n=573), revealed a number of sometimes surprising issues and themes for the digital objects to address. The research, therefore, offers insight into the types of concerns that any college, whether in Ireland or further afield, needs to take into consideration, if it is to genuinely assist what can be a difficult transition for the international student. That said, while there are a number of themes that emerged that have international implications there are other themes that have a particular resonance for the Irish HE sector.

Keywords: international, transition, support, inclusion

Procedia PDF Downloads 198
873 Establish a Company in Turkey for Foreigners

Authors: Mucahit Unal, Ibrahim Arslan

Abstract:

The New Turkish Commercial Code (TCC) No. 6102 was published in the Official Gazette on February 14, 2011. As stated in the New Turkish Commercial Code No. 6102 and Law No. 6103 on Validity and Application of the Turkish Commercial Code, TCC came into effect on July 1, 2012. The basic purpose of the TCC is to form corporate governance coherent with the international standards; to provide transparency in company management; to adjust the Turkish Commercial Code rules with European Union legislations and to simplify establishing a company for foreigner investors to move investments to Turkish market. In this context according to TCC, joint stock companies and limited liability companies can establish with only one single shareholder; the one single shareholder can be foreigner; all board of director members can be foreigner, also all shareholders and board of director members can be non-resident foreigners. Additionally, TCC does not require physical participation to the general shareholders and board members meetings. TCC allows that the general shareholders and board members meetings can hold in an electronic form and resolution of these meetings may also be approved via electronic signatures. Through this amendment, foreign investors no longer have to deal with red tapes. This amendment also means the TCC prevents foreign companies from incurring unnecessary travel expenses. In accordance with all this amendments about TCC, to invest in Turkish market is easy, simple and transparent for foreigner investors and also investors can establish a company in Turkey, irrespective of nationality or place of residence. This article aims to analyze ‘Establish a Company in Turkey for Foreigners’ and inform investors about investing (especially establishing a company) in the Turkish market.

Keywords: establish a company, foreigner investors, invest in Turkish market, Turkish commercial code

Procedia PDF Downloads 239
872 The Misuse of Free Cash and Earnings Management: An Analysis of the Extent to Which Board Tenure Mitigates Earnings Management

Authors: Michael McCann

Abstract:

Managerial theories propose that, in joint stock companies, executives may be tempted to waste excess free cash on unprofitable projects to keep control of resources. In order to conceal their projects' poor performance, they may seek to engage in earnings management. On the one hand, managers may manipulate earnings upwards in order to post ‘good’ performances and safeguard their position. On the other, since managers pursuit of unrewarding investments are likely to lead to low long-term profitability, managers will use negative accruals to reduce current year’s earnings, smoothing earnings over time in order to conceal the negative effects. Agency models argue that boards of directors are delegated by shareholders to ensure that companies are governed properly. Part of that responsibility is ensuring the reliability of financial information. Analyses of the impact of board characteristics, particularly board independence on the misuse of free cash flow and earnings management finds conflicting evidence. However, existing characterizations of board independence do not account for such directors gaining firm-specific knowledge over time, influencing their monitoring ability. Further, there is little analysis of the influence of the relative experience of independent directors and executives on decisions surrounding the use of free cash. This paper contributes to this literature regarding the heterogeneous characteristics of boards by investigating the influence of independent director tenure on earnings management and the relative tenures of independent directors and Chief Executives. A balanced panel dataset comprising 51 companies across 11 annual periods from 2005 to 2015 is used for the analysis. In each annual period, firms were classified as conducting earnings management if they had discretionary accruals in the bottom quartile (downwards) and top quartile (upwards) of the distributed values for the sample. Logistical regressions were conducted to determine the marginal impact of independent board tenure and a number of control variables on the probability of conducting earnings management. The findings indicate that both absolute and relative measures of board independence and experience do not have a significant impact on the likelihood of earnings management. It is the level of free cash flow which is the major influence on the probability of earnings management. Higher free cash flow increases the probability of earnings management significantly. The research also investigates whether board monitoring of earnings management is contingent on the level of free cash flow. However, the results suggest that board monitoring is not amplified when free cash flow is higher. This suggests that the extent of earnings management in companies is determined by a range of company, industry and situation-specific factors.

Keywords: corporate governance, boards of directors, agency theory, earnings management

Procedia PDF Downloads 206
871 Multilayer Thermal Screens for Greenhouse Insulation

Authors: Clara Shenderey, Helena Vitoshkin, Mordechai Barak, Avraham Arbel

Abstract:

Greenhouse cultivation is an energy-intensive process due to the high demands on cooling or heating according to external climatic conditions, which could be extreme in the summer or winter seasons. The thermal radiation rate inside a greenhouse depends mainly on the type of covering material and greenhouse construction. Using additional thermal screens under a greenhouse covering combined with a dehumidification system improves the insulation and could be cost-effective. Greenhouse covering material usually contains protective ultraviolet (UV) radiation additives to prevent the film wear, insect harm, and crop diseases. This paper investigates the overall heat transfer coefficient, or U-value, for greenhouse polyethylene covering contains UV-additives and glass covering with or without a thermal screen supplement. The hot-box method was employed to evaluate overall heat transfer coefficients experimentally as a function of the type and number of the thermal screens. The results show that the overall heat transfer coefficient decreases with increasing the number of thermal screens as a hyperbolic function. The overall heat transfer coefficient highly depends on the ability of the material to reflect thermal radiation. Using a greenhouse covering, i.e., polyethylene films or glass, in combination with high reflective thermal screens, i.e., containing about 98% of aluminum stripes or aluminum foil, the U-value reduces by 61%-89% in the first case, whereas by 70%-92% in the second case, depending on the number of the thermal screen. Using thermal screens made from low reflective materials may reduce the U-value by 30%-57%. The heat transfer coefficient is an indicator of the thermal insulation properties of the materials, which allows farmers to make decisions on the use of appropriate thermal screens depending on the external and internal climate conditions in a greenhouse.

Keywords: energy-saving thermal screen, greenhouse cover material, heat transfer coefficient, hot box

Procedia PDF Downloads 124
870 Surface Coatings of Boards Made from Alternative Materials

Authors: Stepan Hysek, Petra Gajdacova

Abstract:

In recent years, alternative materials, such as annual plants or recycled and waste materials are becoming more and more popular input material for the production of composite materials. They can be used for the production of insulation boards, construction boards or furniture boards. Surface finishing of those boards is essential for utilization in furniture. However, some difficulties could occur during coating of boards from alternative materials; physical and chemical differences from conventional particleboards need to be considered. From the physical aspects, surface soundness and surface roughness mainly determine the quality of the surface. Since surface layers of boards from alternative materials have often lower density, these characteristics could be deteriorated and thus the production process needs to be optimized. Also, chemical reactions of board’s material with coating could be undesirable. The objective of this study is to evaluate the parameters affecting the surface quality of boards made form alternative materials and to find possibilities of the coating of these boards. In this study, boards of particles from rapeseed stems were produced using a laboratory press. Surface soundness, as representatives of mechanical properties and surface roughness, as representative of physical properties, were measured on boards from rapeseed stems. Results clearly indicated that produced boards had lower surface quality than commercially produced particle boards from wood. Therefore, higher thickness of surface coating on rapeseed based boards is needed.

Keywords: coating, surface, annual plant, composites, particleboard

Procedia PDF Downloads 239
869 Durability of Cement Bonded Particleboards Produced from Terminalia superba and Gmelina arborea against Subterranean Termite Attack

Authors: Amos Olajide Oluyege, Emmanuel Uchechukwu Opara, Sunday Adeniyi Adedutan, Joseph Adeola Fuwape

Abstract:

This study was conducted to determine the durability of wood-cement particleboards when exposed to attack by subterranean termites, Macrotermes subhylinus. The boards were made from Terminalia superba and Gmelina arborea wood sawdust at nominal board densities (BD) of 1000, 900, and 800 kg/m³ using wood-cement mixing ratios (MR) of 3:1, 2.5:1, 2:1, and 1:1. Above ground durability tests against termite attack were carried out according to ASTM D 2017 for 14 weeks. Results of visual assessment of the wood cement particleboards show that all the board samples had a visual rating that was not less than 7 (i.e., moderate attack) for both species irrespective of the MR and BD. T. superba boards were found to have higher resistance to termite attack compared to their G. arborea counterparts. The mean values for weight loss following exposure ranged from 1.93 to 6.13% and 3.24 to 12.44%. Analysis of variance (ANOVA) results of the weight loss assessment revealed a significant (p < 0.05) effect of species and mixing ratio on the weight loss of the boards due to termite attack with F(₁,₇₂) = 92.890 and P = 0.000 and F(₃,₇₂) = 8.318 and p = 0.000, while board density did not have any significant effect (p > 0.05) with F (₂,₇₂) = 1.307 and p = 0.277. Thus, boards made from a higher mixing ratio had better resistance against termite attacks. Thus, it can be concluded that the durability of cement-bonded particleboards when exposed to subterranean termite attack is not only dependent on the quality of the wood raw material (species) but also on the enhanced protection imparted by the cement matrix; the protection increased with increase in cement/wood mixing ratio.

Keywords: cement-bonded particleboard, mixing ratio, board density, Gmelina arborea, Terminalia superba

Procedia PDF Downloads 189
868 Challenges and Future Prospects of Teaching English in Secondary Schools of Jharkhand Board: An Extensive Survey of the Present Status

Authors: Neha Toppo

Abstract:

Plans and programs for successful secondary education are incomplete without the inclusion of teaching English as an important area. Even after sixteen years of the formation of Jharkhand as a separate state, the students are still struggling to achieve quality education of English. This paper intends to account the present condition of teaching English in Jharkhand board secondary level schools through discussion on various issues of English language teaching, language need and learning challenges of its students. The study is to analyze whether the learning environment, teaching methods and materials, teaching resources, goals of language curriculum are appropriately convincing for the students of the board or require to be reanalyzed and also to provide appropriate suggestions for improvement. Immediate attention must be drawn towards the problem for benefitting those students, who despite their knowledge and talent are lagging behind in numerous fields only due to the lack of proficiency in English. The data and discussion provided are on the basis of a survey, in which semi structured interview with teachers, students and administrators in several schools including both rural and urban area has been taken. Questionnaire, observation and testing were used as important tools. The survey has been conducted in Ranchi district, as it covers large geographical area which includes number of villages and at the same time several towns. The district primarily possesses tribes as well as different class of people including immigrants from all over and outside Jharkhand with their social, economical strata. The observation makes it clear that the English language teaching at the state board is not complementing its context and the whole language teaching system should be re-examined to establish learner oriented environment.

Keywords: material, method, secondary level, teaching resources

Procedia PDF Downloads 547
867 Comparison of Traditional and Green Building Designs in Egypt: Energy Saving

Authors: Hala M. Abdel Mageed, Ahmed I. Omar, Shady H. E. Abdel Aleem

Abstract:

This paper describes in details a commercial green building that has been designed and constructed in Marsa Matrouh, Egypt. The balance between homebuilding and the sustainable environment has been taken into consideration in the design and construction of this building. The building consists of one floor with 3 m height and 2810 m2 area while the envelope area is 1400 m2. The building construction fulfills the natural ventilation requirements. The glass curtain walls are about 50% of the building and the windows area is 300 m2. 6 mm greenish gray tinted temper glass as outer board lite, 6 mm safety glass as inner board lite and 16 mm thick dehydrated air spaces are used in the building. Visible light with 50% transmission, 0.26 solar factor, 0.67 shading coefficient and 1.3 W/m2.K thermal insulation U-value are implemented to realize the performance requirements. Optimum electrical distribution for lighting system, air conditions and other electrical loads has been carried out. Power and quantity of each type of the lighting system lamps and the energy consumption of the lighting system are investigated. The design of the air conditions system is based on summer and winter outdoor conditions. Ventilated, air conditioned spaces and fresh air rates are determined. Variable Refrigerant Flow (VRF) is the air conditioning system used in this building. The VRF outdoor units are located on the roof of the building and connected to indoor units through refrigerant piping. Indoor units are distributed in all building zones through ducts and air outlets to ensure efficient air distribution. The green building energy consumption is evaluated monthly all over one year and compared with the consumed energy in the non-green conditions using the Hourly Analysis Program (HAP) model. The comparison results show that the total energy consumed per year in the green building is about 1,103,221 kWh while the non-green energy consumption is about 1,692,057 kWh. In other words, the green building total annual energy cost is reduced from 136,581 $ to 89,051 $. This means that, the energy saving and consequently the money-saving of this green construction is about 35%. In addition, 13 points are awarded by applying one of the most popular worldwide green energy certification programs (Leadership in Energy and Environmental Design “LEED”) as a rating system for the green construction. It is concluded that this green building ensures sustainability, saves energy and offers an optimum energy performance with minimum cost.

Keywords: energy consumption, energy saving, green building, leadership in energy and environmental design, sustainability

Procedia PDF Downloads 281
866 Thermal, Chemical, and Mineralogical Properties of Soil Building Blocks Reinforced with Cement

Authors: Abdelmalek Ammari

Abstract:

This paper represents an experimental study to determine the effect between thermal conductivity of Compressed Earth Block Stabilized (CEBs) by cement and the mineralogical and chemical analyses of soil, all the samples of CEB in the dry state and with different content of cement, the samples made by soil stabilized by Portland Cement. The soil used collected from fez city in Morocco. That determination of the thermal conductivity of CEBs plays an important role when considering its suitability for energy saving insulation. The measurement technique used to determine thermal conductivity is called hot ring method, the thermal conductivity of the tested samples is strongly affected by the quantity of the cement added. The soil of Fez, mainly composed of calcite, quartz, and dolomite, improved the behaviour of the material by the addition of cement. The findings suggest that to manufacture lightweight samples with high thermal insulation properties, it is advisable to use clays that contain quartz. . In addition, quartz has high thermal conductivity.

Keywords: compressed earth blocks, thermal conductivity, mineralogical, chemical, temperature

Procedia PDF Downloads 130
865 The Impact of Corporate Governance, Ownership Structure, and Cash Holdings on Firm Value with Profitability as Intervening Variable

Authors: Lucy Novianti

Abstract:

The purpose of this study is to determine the effect of corporate governance, ownership structure, and cash holdings on firm value, either direct or indirect through profitability as an intervening variable for non-financial companies listed on the Indonesia Stock Exchange during 2006 to 2014. Samples of 176 firms are chosen based on purposive sampling method. The results of this study conclude that profitability, the size of Audit Committee, audit quality, and cash flow have positive effects on firm value. This study also shows that the meeting frequency of the Board of Directors and free cash flow have negative effects on firm value. In addition, this study finds that the size of the Board of Directors, Independent Commissioner, and ownership structure do not have significant effects on firm value. In this study, the function of profitability as an intervening variable can only be done on the impact of the meeting frequency of the Board of Directors and cash flow on firm value. This study provides a reference for management in decision making concerning the application of corporate governance, cash holdings, and financial performance. Moreover, it can be used as additional information for investors in assessing the feasibility of an investment. Finally, it provides a suggestion for the government regarding the regulation of corporate governance.

Keywords: cash holdings, corporate governance, firm value, ownership structure, profitability

Procedia PDF Downloads 234
864 Retrofitting Insulation to Historic Masonry Buildings: Improving Thermal Performance and Maintaining Moisture Movement to Minimize Condensation Risk

Authors: Moses Jenkins

Abstract:

Much of the focus when improving energy efficiency in buildings fall on the raising of standards within new build dwellings. However, as a significant proportion of the building stock across Europe is of historic or traditional construction, there is also a pressing need to improve the thermal performance of structures of this sort. On average, around twenty percent of buildings across Europe are built of historic masonry construction. In order to meet carbon reduction targets, these buildings will require to be retrofitted with insulation to improve their thermal performance. At the same time, there is also a need to balance this with maintaining the ability of historic masonry construction to allow moisture movement through building fabric to take place. This moisture transfer, often referred to as 'breathable construction', is critical to the success, or otherwise, of retrofit projects. The significance of this paper is to demonstrate that substantial thermal improvements can be made to historic buildings whilst avoiding damage to building fabric through surface or interstitial condensation. The paper will analyze the results of a wide range of retrofit measures installed to twenty buildings as part of Historic Environment Scotland's technical research program. This program has been active for fourteen years and has seen interventions across a wide range of building types, using over thirty different methods and materials to improve the thermal performance of historic buildings. The first part of the paper will present the range of interventions which have been made. This includes insulating mass masonry walls both internally and externally, warm and cold roof insulation and improvements to floors. The second part of the paper will present the results of monitoring work which has taken place to these buildings after being retrofitted. This will be in terms of both thermal improvement, expressed as a U-value as defined in BS EN ISO 7345:1987, and also, crucially, will present the results of moisture monitoring both on the surface of masonry walls the following retrofit and also within the masonry itself. The aim of this moisture monitoring is to establish if there are any problems with interstitial condensation. This monitoring utilizes Interstitial Hygrothermal Gradient Monitoring (IHGM) and similar methods to establish relative humidity on the surface of and within the masonry. The results of the testing are clear and significant for retrofit projects across Europe. Where a building is of historic construction the use of materials for wall, roof and floor insulation which are permeable to moisture vapor provides both significant thermal improvements (achieving a u-value as low as 0.2 Wm²K) whilst avoiding problems of both surface and intestinal condensation. As the evidence which will be presented in the paper comes from monitoring work in buildings rather than theoretical modeling, there are many important lessons which can be learned and which can inform retrofit projects to historic buildings throughout Europe.

Keywords: insulation, condensation, masonry, historic

Procedia PDF Downloads 146
863 An Innovative Approach to Improve Skills of Students in Qatar University Spending in Virtual Class though LMS

Authors: Mohammad Shahid Jamil

Abstract:

In this study we have investigated students’ learning and satisfaction in one of the course offered in the Foundation Program at Qatar University. We implied innovative teaching methodology that emphasizes on enhancing students’ thinking skills, decision making, and problem solving skills. Some interesting results were found which can be used to further improve the teaching methodology. To make sure the full use of technology in Foundation Program at Qatar University has started implementing new ways of teaching Math course by using Blackboard as an innovative interactive tool to support standard teaching such as Discussion board, Virtual class, and Study plan in My Math Lab “MML”. In MML Study Plan is designed in such a way that the student can improve their skills wherever they face difficulties with in their Homework, Quiz or Test. Discussion board and Virtual Class are collaborative learning tools encourages students to engage outside of class time. These tools are useful to share students’ knowledge and learning experiences, promote independent and active learning and they helps students to improve their critical thinking skills through the learning process.

Keywords: blackboard, discussion board, critical thinking, active learning, independent learning, problem solving

Procedia PDF Downloads 407