Search results for: biceps brachii rupture
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 238

Search results for: biceps brachii rupture

208 Experimental and Numerical Studies on Earthquake Shear Rupture Generation

Authors: Louis N. Y. Wong

Abstract:

En-echelon fractures are commonly found in rocks, which appear as a special set of regularly oriented and spaced fractures. By using both experimental and numerical approaches, this study investigates the interaction among them, and how this interaction finally contributes to the development of a shear rupture (fault), especially in brittle natural rocks. Firstly, uniaxial compression tests are conducted on marble specimens containing en-echelon flaws. The latter is cut by using the water abrasive jet into the rock specimens. The fracturing processes of these specimens leading to the formation of a fault are observed in detail by the use of a high speed camera. The influences of the flaw geometry on the production of tensile cracks and shear cracks, which in turn dictate the coalescence patterns of the entire set of en-echelon flaws are comprehensively studied. Secondly, a numerical study based on a recently developed contact model, flat-joint contact model using the discrete element method (DEM) is carried out to model the present laboratory experiments. The numerical results provide a quantitative assessment of the interaction of en-echelon flaws. Particularly, the evolution of the stress field, as well as the characteristics of new crack initiation, propagation and coalescence associated with the generation of an eventual shear rupture are studied in detail. The numerical results are found to agree well with the experimental results obtained in both microscopic and macroscopic observations.

Keywords: discrete element method, en-echelon flaws, fault, marble

Procedia PDF Downloads 255
207 Strength Translation from Spun Yarns to Woven Fabrics

Authors: Anindya Ghosh

Abstract:

Structural parameters, yarn to yarn friction, strength of ring, rotor, air-jet and open-end friction spun yarns and the strength of fabrics made from these yarns are measured. The ratio of fabric strip strength per yarn and corresponding single yarn strength is considered as a measure of quantifying the fabric assistance. Mechanism of yarn failure inside the fabric is different as that of single yarn and the former exhibit more fibre rupture. Fabrics made from weaker yarns have higher ratio of strip strength to single yarn strength than that made from stronger yarns due to larger increase in the percentage of rupture fibres in the former. The fabric assistance also depends to some extent on the degree of gripping of the yarns that is influenced by the yarn to yarn friction, extent of yarn flattening and yarn diameter.

Keywords: fabric assistance, fabric strength, yarn diameter, yarn friction, yarn strength

Procedia PDF Downloads 249
206 Spontaneous Rupture of Splenic Artery Pseudoaneurysm; A Rare Presentation of Acute Abdominal Pain in the Emergency Department: Case Report

Authors: Zainab Elazab, Azhar Aziz

Abstract:

Background: Spontaneous Splenic artery pseudoaneurysm rupture is a rare condition which is potentially life threatening, if not detected and managed early. We report a case of abdominal pain with intraperitoneal free fluid, which turned out to be spontaneous rupture of a splenic artery pseudoaneurysm, and was treated with arterial embolization. Case presentation: A 28-year old, previously healthy male presented to the ED with a history of sudden onset upper abdominal pain and fainting attack. The patient denied any history of trauma or prior similar attacks. On examination, the patient had tachycardia and a low-normal BP (HR 110, BP 106/66) but his other vital signs were normal (Temp. 37.2, RR 18 and SpO2 100%). His abdomen was initially soft with mild tenderness in the upper region. Blood tests showed leukocytosis of 12.3 X109/L, Hb of 12.6 g/dl and lactic acid of 5.9 mmol/L. Ultrasound showed trace of free fluid in the perihepatic and perisplenic areas, and a splenic hypoechoic lesion. The patient remained stable; however, his abdomen became increasingly tender with guarding. We made a provisional diagnosis of a perforated viscus and the patient was started on IV fluids and IV antibiotics. An erect abdominal x-ray did not show any free air under the diaphragm so a CT abdomen was requested. Meanwhile, bedside ultrasound was repeated which showed increased amount of free fluid, suggesting intra-abdominal bleeding as the most probable etiology for the condition. His CT abdomen revealed a splenic injury with multiple lacerations, a focal intrasplenic enhancing area on venous phase scan (suggesting a pseudoaneurysm with associated splenic intraparenchymal, sub capsular and perisplenic hematomas). Free fluid in the subhepatic and intraperitoneal regions along the small bowel was also detected. Angiogram was done which confirmed a diagnosis of pseudoaneurysm of intrasplenic arterial branch, and angio-embolization was done to control the bleeding. The patient was later discharged in good condition with a surgery follow-up. Conclusion: Splenic artery pseudoaneurysm rupture is a rare cause of abdominal pain which should be considered in any case of abdominal pain with intraperitoneal bleeding. Early management is crucial as it carries a high mortality. Bedside ultrasound is a useful tool to help for early diagnosis of such cases.

Keywords: abdominal pain, pseudo aneurysm, rupture, splenic artery

Procedia PDF Downloads 310
205 The Characteristics of the Fragments from Cylindrical Casing with One of End Caps Fully Constrained

Authors: Yueguang Gao, Qi Huang, Shunshan Feng

Abstract:

In order to study the process and characteristic of the fragments in the warhead with one end cap under full constraint condition, we established a cylindrical casing with two end caps which one of which was fully constrained using the simulation analysis. The result showed that the fragmentation of cylindrical casing with one end full constrained has its own characteristic. The Mach stem was generated when the detonation wave propagated to the fully constrained end cap under the condition of one end detonation, working on unreactive explosives and causing the nearby fragment subjected to nearly 2.5 times the normal pressure to obtain a higher speed. The cylindrical casing first ruptured at the contact surface with the fully constrained end, and then at the end cover of the initiating end, and then the rupture extends to the whole cylindrical casing. The detonation products started to leak out from the rupture. Driving fragments to fly and forming two dense flying areas. The analysis of this paper can provide a reference for the optimal design of this kind of warhead.

Keywords: fragment, cylindrical casing, detonation waves, numerical simulation

Procedia PDF Downloads 124
204 Rupture Probability of Type of Coarse Aggregate on Fracture Surface of Concrete

Authors: B. Ramakrishna, S. Sivamurthy Reddy

Abstract:

The various types of aggregates such as granite, dolerite, Quartzite, dolomitic limestone, limestone and river gravel were used to produce the concrete with 28-day target compressive strength of 35, 60, and 80 Mpa. The compressive strength of concrete, as well as aggregates, was measured to study the effect of rupture probability of aggregate on the fracture surface of the concrete. Also, the petrographic studies were carried out to study the texture, type of minerals present and their relative proportions in various types of aggregates. The concrete of various grades produced with the same aggregate has shown a rise in RPCA with strength. However, the above relationship has ceased to exist in the concretes of the same grade, made of different types of aggregates. The carbonate aggregates namely Limestone and Dolomitic limestone have produced concrete with higher RPCA irrespective of the strength of concrete. The mode of origin, texture and mineralogical composition of aggregates have a significant impact on their pulse velocity and thereby the pulse velocity of concrete.

Keywords: RPCA, DL, G, LS, RG

Procedia PDF Downloads 294
203 The Development of Cardiac Tamponade after Spinal Surgery in a Patient with Duchenne Muscular Dystrophy

Authors: Hacer Y. Teke, Sultan Pehlivan, Mustafa Karapırlı, Asude Gökmen, Sait Özsoy

Abstract:

The case is here presented of a patient with DMD with electrocardiograph findings within normal limits who underwent spinal surgery then developed the rarely seen complication of cardiac tamponade which resulted in death. A 17-year old male with DMD was admitted to hospital for spinal surgery. Due to a postoperative drop in hemoglobin, blood transfusion was administered to the patient, no complication developed and he was discharged on the third day. Four days after discharge, the patient worsened at home and an ambulance was called. Before the nearest hospital was reached, the patient died in the ambulance. An autopsy was performed. A fatal but rarely seen complication of Acute Myocardial Infarction (AMI) is myocardial rupture. 85% of ruptures occur in the first week of AMI but just as they can be seen on the day of the infarct, they can also be seen 2 weeks later. The case presented here had infarction findings related to different times and in different areas.

Keywords: duchenne muscular dystrophy, myocardial infarction, myocardial rupture, anesthesia

Procedia PDF Downloads 482
202 Internal Corrosion Rupture of a 6-in Gas Line Pipe

Authors: Fadwa Jewilli

Abstract:

A sudden leak of a 6-inch gas line pipe after being in service for one year was observed. The pipe had been designed to transport dry gas. The failure had taken place in 6 o’clock position at the stage discharge of the flow process. Laboratory investigations were conducted to find out the cause of the pipe rupture. Visual and metallographic observations confirmed that the pipe split was due to a crack initiated in circumferential and then turned into longitudinal direction. Sever wall thickness reduction was noticed on the internal pipe surface. Scanning electron microscopy observations at the fracture surface revealed features of ductile fracture mode. Corrosion product analysis showed the traces of iron carbonate and iron sulphate. The laboratory analysis resulted in the conclusion that the pipe failed due to the effect of wet fluid (condensate) caused severe wall thickness dissolution resulted in pipe could not stand the continuation at in-service working condition.

Keywords: gas line pipe, corrosion prediction ductile fracture, ductile fracture, failure analysis

Procedia PDF Downloads 84
201 Minimum Ratio of Flexural Reinforcement for High Strength Concrete Beams

Authors: Azad A. Mohammed, Dunyazad K. Assi, Alan S. Abdulrahman

Abstract:

Current ACI 318 Code provides two limits for minimum steel ratio for concrete beams. When concrete compressive strength be larger than 31 MPa the limit of √(fc')/4fy usually governs. In this paper shortcomings related to using this limit was fairly discussed and showed that the limit is based on 90% safety factor and was derived based on modulus of rupture equation suitable for concretes of compressive strength lower than 31 MPa. Accordingly, the limit is nor suitable and critical for concretes of higher compressive strength. An alternative equation was proposed for minimum steel ratio of rectangular beams and was found that the proposed limit is accurate for beams of wide range of concrete compressive strength. Shortcomings of the current ACI 318 Code equation and accuracy of the proposed equation were supported by test data obtained from testing six reinforced concrete beams.

Keywords: concrete beam, compressive strength, minimum steel ratio, modulus of rupture

Procedia PDF Downloads 550
200 Mechanical Properties of Enset Fibers Obtained from Different Breeds of Enset Plant

Authors: Diriba T. Balcha, Boris Kulig, Oliver Hensel, Eyassu Woldesenbet

Abstract:

Enset fiber is agricultural waste and available in a surplus amount in Ethiopia. However, the hypothesized variation in properties of this fiber due to diversity of its plant source breed, fiber position within plant stem and chemical treatment duration had not proven that its application for the development of composite products is problematic. Currently, limited data are known on the functional properties of the fiber as a potential functional fiber. Thus, an effort is made in this study to narrow the knowledge gaps by characterizing it. The experimental design was conducted using Design-Expert software and the tensile test was conducted on Enset fiber from 10 breeds: Dego, Dirbo, Gishera, Itine, Siskela, Neciho, Yesherkinke, Tuzuma, Ankogena, and Kucharkia. The effects of 5% Na-OH surface treatment duration and fiber location along and across the plant pseudostem was also investigated. The test result shows that the rupture stress variation is not significant among the fibers from 10 Enset breeds. However, strain variation is significant among the fibers from 10 Enset breeds that breed Dego fiber has the highest strain before failure. Surface treated fibers showed improved rupture strength and elastic modulus per 24 hours of treatment duration. Also, the result showed that chemical treatment can deteriorate the load-bearing capacity of the fiber. The raw fiber has the higher load-bearing capacity than the treated fiber. And, it was noted that both the rupture stress and strain increase in the top to bottom gradient, whereas there is no significant variation across the stem. Elastic modulus variation both along and across the stem was insignificant. The rupture stress, elastic modulus, and strain result of Enset fiber are 360.11 ± 181.86 MPa, 12.80 ± 6.85 GPa and 0.04 ± 0.02 mm/mm, respectively. These results show that Enset fiber is comparable to other natural fibers such as abaca, banana, and sisal fibers and can be used as alternatives natural fiber for composites application. Besides, the insignificant variation of properties among breeds and across stem is essential for all breeds and all leaf sheath of the Enset fiber plant for fiber extraction. The use of short natural fiber over the long is preferable to reduce the significant variation of properties along the stem or fiber direction. In conclusion, Enset fiber application for composite product design and development is mechanically feasible.

Keywords: Agricultural waste, Chemical treatment, Fiber characteristics, Natural fiber

Procedia PDF Downloads 236
199 Comparison of Cervical Length Using Transvaginal Ultrasonography and Bishop Score to Predict Succesful Induction

Authors: Lubena Achmad, Herman Kristanto, Julian Dewantiningrum

Abstract:

Background: The Bishop score is a standard method used to predict the success of induction. This examination tends to be subjective with high inter and intraobserver variability, so it was presumed to have a low predictive value in terms of the outcome of labor induction. Cervical length measurement using transvaginal ultrasound is considered to be more objective to assess the cervical length. Meanwhile, this examination is not a complicated procedure and less invasive than vaginal touché. Objective: To compare transvaginal ultrasound and Bishop score in predicting successful induction. Methods: This study was a prospective cohort study. One hundred and twenty women with singleton pregnancies undergoing induction of labor at 37 – 42 weeks and met inclusion and exclusion criteria were enrolled in this study. Cervical assessment by both transvaginal ultrasound and Bishop score were conducted prior induction. The success of labor induction was defined as an ability to achieve active phase ≤ 12 hours after induction. To figure out the best cut-off point of cervical length and Bishop score, receiver operating characteristic (ROC) curves were plotted. Logistic regression analysis was used to determine which factors best-predicted induction success. Results: This study showed significant differences in terms of age, premature rupture of the membrane, the Bishop score, cervical length and funneling as significant predictors of successful induction. Using ROC curves found that the best cut-off point for prediction of successful induction was 25.45 mm for cervical length and 3 for Bishop score. Logistic regression was performed and showed only premature rupture of membranes and cervical length ≤ 25.45 that significantly predicted the success of labor induction. By excluding premature rupture of the membrane as the indication of induction, cervical length less than 25.3 mm was a better predictor of successful induction. Conclusion: Compared to Bishop score, cervical length using transvaginal ultrasound was a better predictor of successful induction.

Keywords: Bishop Score, cervical length, induction, successful induction, transvaginal sonography

Procedia PDF Downloads 325
198 The Flexural Improvement of RC Beams Using an Inserted Plate between Concrete and FRP Bonding Surface

Authors: Woo Young Jung, Min Ho Kwon, Bu Seog Ju

Abstract:

The primary objective of this research is to improve the flexural capacity of FRP strengthened RC Beam structures with Aluminum and Titanium laminates. FRP rupture of flexural strengthened RC beams using FRP plates generally occurs at the interface between FRP plate and the beam. Therefore, in order to prevent brittle rupture and improve the ductility of the system, this research was performed by using Aluminum and Titanium materials between the two different structural systems. The research also aims to provide various strengthening/retrofitting methods for RC beam structures and to conduct a preliminary analysis of the demands on the structural systems. This was achieved by estimation using the experimental data from this research to identify a flexural capacity for the systems. Ultimately, the preliminary analysis of current study showed that the flexural capacity and system demand ductility was significantly improved by the systems inserted with Aluminum and Titanium anchor plates. Further verification of the experimental research is currently on its way to develop a new or reliable design guideline to retrofit/strengthen the concrete-FRP structural system can be evaluated.

Keywords: reinforced concrete, FRP laminate, flexural capacity, ductility

Procedia PDF Downloads 291
197 Outcome of Induction of Labour by Cervical Ripening with an Osmotic Dilator in a District General Hospital

Authors: A. Wahid Uddin

Abstract:

Osmotic dilator for cervical ripening bypasses the initial hormonal exposure necessary for a routine method of induction. The study was a clinical intervention with an osmotic dilator followed by prospective observation. The aim was to calculate the percentage of women who had successful cervical ripening using modified BISHOP score as evidenced by artificial rupture of membrane. The study also estimated the delivery interval following a single administration of osmotic dilators. Randomly selected patients booked for induction of labour accepting the intervention were included in the study. The study population comprised singleton term pregnancy, cephalic presentation, intact membranes with a modified BISHOP score of less than 6. Initial sample recruited was 30, but 6 patients left the study and the study was concluded on 24 patients. The data were collected in a pre-designed questionnaire and analysis were expressed in percentages along with using mean value for continuous variables. In 70 % of cases, artificial rupture of the membrane was possible and the mean time from insertion of the osmotic dilator to the delivery interval was 30 hours. The study concluded that an osmotic dilator could be a suitable alternative for hormone-based induction of labour.

Keywords: dilator, induction, labour, osmotic

Procedia PDF Downloads 138
196 Quick off the Mark with Achilles Tendon Rupture

Authors: Emily Moore, Andrew Gaukroger, Matthew Solan, Lucy Bailey, Alexandra Boxall, Andrew Carne, Chintu Gadamsetty, Charlotte Morley, Katy Western, Iwona Kolodziejczyk

Abstract:

Introduction: Rupture of the Achilles tendon is common and has a long recovery period. Most cases are managed non-operatively. Foot and Ankle Surgeons advise an ultrasound scan to check the gap between the torn ends. A large gap (with the ankle in equinus) is a relative indication for surgery. The definitive decision regarding surgical versus non-operative management can only be made once an ultrasound scan is undertaken and the patient is subsequently reviewed by a Foot and Ankle surgeon. To get to this point, the patient journey involves several hospital departments. In nearby trusts, patients reattend for a scan and go to the plaster room both before and after the ultrasound for removal and re-application of the cast. At a third visit to the hospital, the surgeon and patient discuss options for definitive treatment. It may take 2-3 weeks from the initial Emergency Department visit before the final treatment decision is made. This “wasted time” is ultimately added to the recovery period for the patient. In this hospital, Achilles rupture patients are seen in a weekly multidisciplinary OneStop Heel Pain clinic. This pathway was already efficient but subject to occasional frustrating delays if a key staff member was absent. A new pathway was introduced with the goal to reduce delays to a definitive treatment plan. Method: A retrospective series of Achilles tendon ruptures managed according to the 2019 protocol was identified. Time taken from the Emergency Department to have both an ultrasound scan and specialist Foot and Ankle surgical review were calculated. 30 consecutive patients were treated with our new pathway and prospectively followed. The time taken for a scan and for specialist review were compared to the 30 consecutive cases from the 2019 (pre-COVID) cohort. The new pathway includes 1. A new contoured splint applied to the front of the injured limb held with a bandage. This can be removed and replaced (unlike a plaster cast) in the ultrasound department, removing the need for plaster room visits. 2. Urgent triage to a Foot and Ankle specialist. 3. Ultrasound scan for assessment of rupture gap and deep vein thrombosis check. 4. Early decision regarding surgery. Transfer to weight bearing in a prosthetic boot in equinuswithout waiting for the once-a-week clinic. 5. Extended oral VTE prophylaxis. Results: The time taken for a patient to have both an ultrasound scan and specialist review fell > 50%. All patients in the new pathway reached a definitive treatment decision within one week. There were no significant differences in patient demographics or rates of surgical vs non-operative treatment. The mean time from Emergency Department visit to specialist review and ultrasound scan fell from 8.7 days (old protocol) to 2.9 days (new pathway). The maximum time for this fell from 23 days (old protocol) to 6 days (new pathway). Conclusion: Teamwork and innovation have improved the experience for patients with an Achilles tendon rupture. The new pathway brings many advantages - reduced time in the Emergency Department, fewer hospital visits, less time using crutches and reduced overall recovery time.

Keywords: orthopaedics, achilles rupture, ultrasound, innovation

Procedia PDF Downloads 123
195 The Influence of Mechanical and Physicochemical Characteristics of Perfume Microcapsules on Their Rupture Behaviour and How This Relates to Performance in Consumer Products

Authors: Andrew Gray, Zhibing Zhang

Abstract:

The ability for consumer products to deliver a sustained perfume response can be a key driver for a variety of applications. Many compounds in perfume oils are highly volatile, meaning they readily evaporate once the product is applied, and the longevity of the scent is poor. Perfume capsules have been introduced as a means of abating this evaporation once the product has been delivered. The impermeable capsules are aimed to be stable within the formulation, and remain intact during delivery to the desired substrate, only rupturing to release the core perfume oil through application of mechanical force applied by the consumer. This opens up the possibility of obtaining an olfactive response hours, weeks or even months after delivery, depending on the nature of the desired application. Tailoring the properties of the polymeric capsules to better address the needs of the application is not a trivial challenge and currently design of capsules is largely done by trial and error. The aim of this work is to have more predictive methods for capsule design depending on the consumer application. This means refining formulations such that they rupture at the right time for the specific consumer application, not too early, not too late. Finding the right balance between these extremes is essential if a benefit is sought with respect to neat addition of perfume to formulations. It is important to understand the forces that influence capsule rupture, first, by quantifying the magnitude of these different forces, and then by assessing bulk rupture in real-world applications to understand how capsules actually respond. Samples were provided by an industrial partner and the mechanical properties of individual capsules within the samples were characterized via a micromanipulation technique, developed by Professor Zhang at the University of Birmingham. The capsules were synthesized such as to change one particular physicochemical property at a time, such as core: wall material ratio, and the average size of capsules. Analysis of shell thickness via Transmission Electron Microscopy, size distribution via the use of a Mastersizer, as well as a variety of other techniques confirmed that only one particular physicochemical property was altered for each sample. The mechanical analysis was subsequently undertaken, showing the effect that changing certain capsule properties had on the response under compression. It was, however, important to link this fundamental mechanical response to capsule performance in real-world applications. As such, the capsule samples were introduced to a formulation and exposed to full scale stresses. GC-MS headspace analysis of the perfume oil released from broken capsules enabled quantification of what the relative strengths of capsules truly means for product performance. Correlations have been found between the mechanical strength of capsule samples and performance in terms of perfume release in consumer applications. Having a better understanding of the key parameters that drive performance benefits the design of future formulations by offering better guidelines on the parameters that can be adjusted without worrying about the performance effects, and singles out those parameters that are essential in finding the sweet spot for capsule performance.

Keywords: consumer products, mechanical and physicochemical properties, perfume capsules, rupture behaviour

Procedia PDF Downloads 131
194 Utilization of Solid Waste Materials to Produce Glass-Ceramic Tiles

Authors: Sonjida Mustafia

Abstract:

Glass-ceramic is a material that contains both the properties of glass and ceramic within. They always contain a residual glassy phase and one or more embedded crystalline phases. Ceramic tiles are very popular in the world because of their high structural strength, low absorption, increased hygiene, and hot and cold insulation. Glass-ceramic materials are used to produce marble-like floor and wall tiles. There are a huge amount of waste materials like rice husk ash (RHA), waste iron, waste glass, and other industrial solid waste in Bangladesh, which can be used to produce glass-ceramic floor and wall tiles. The raw materials (rice husk ash, waste glass, and k-feldspar) are a mixture, and the mixture is melted to form glass frit at 1175°C. The frits are grained to require fine particle size. The powder is moistened in 7-8% water with sodium silicate. The green glass-ceramic tiles were fired at different temperatures (800–1100°C) for a soaking time of 1 hour to form glass-ceramic tiles and to study the sintering-crystallization process. The results reveal that the modulus of rupture increases with increasing sintering temperature and reaches the highest value (95.25Mpa) at 925°C. Glossiness and linear shrinkage increase with increasing temperature.

Keywords: rice husk ash, waste glass, glass-ceramic, modulus of rupture, glossiness, linear shrinkage, micro-structure

Procedia PDF Downloads 93
193 Repair of Thermoplastic Composites for Structural Applications

Authors: Philippe Castaing, Thomas Jollivet

Abstract:

As a result of their advantages, i.e. recyclability, weld-ability, environmental compatibility, long (continuous) fiber thermoplastic composites (LFTPC) are increasingly used in many industrial sectors (mainly automotive and aeronautic) for structural applications. Indeed, in the next ten years, the environmental rules will put the pressure on the use of new structural materials like composites. In aerospace, more than 50% of the damage are due to stress impact and 85% of damage are repaired on the fuselage (fuselage skin panels and around doors). With the arrival of airplanes mainly of composite materials, replacement of sections or panels seems difficult economically speaking and repair becomes essential. The objective of the present study is to propose a solution of repair to prevent the replacement the damaged part in thermoplastic composites in order to recover the initial mechanical properties. The classification of impact damage is not so not easy : talking about low energy impact (less than 35 J) can be totally wrong when high speed or weak thicknesses as well as thermoplastic resins are considered. Crash and perforation with higher energy create important damages and the structures are replaced without repairing, so we just consider here damages due to impacts at low energy that are as follows for laminates : − Transverse cracking; − Delamination; − Fiber rupture. At low energy, the damages are barely visible but can nevertheless reduce significantly the mechanical strength of the part due to resin cracks while few fiber rupture is observed. The patch repair solution remains the standard one but may lead to the rupture of fibers and consequently creates more damages. That is the reason why we investigate the repair of thermoplastic composites impacted at low energy. Indeed, thermoplastic resins are interesting as they absorb impact energy through plastic strain. The methodology is as follows: - impact tests at low energy on thermoplastic composites; - identification of the damage by micrographic observations; - evaluation of the harmfulness of the damage; - repair by reconsolidation according to the extent of the damage ; -validation of the repair by mechanical characterization (compression). In this study, the impacts tests are performed at various levels of energy on thermoplastic composites (PA/C, PEEK/C and PPS/C woven 50/50 and unidirectional) to determine the level of impact energy creating damages in the resin without fiber rupture. We identify the extent of the damage by US inspection and micrographic observations in the plane part thickness. The samples were in addition characterized in compression to evaluate the loss of mechanical properties. Then the strategy of repair consists in reconsolidating the damaged parts by thermoforming, and after reconsolidation the laminates are characterized in compression for validation. To conclude, the study demonstrates the feasibility of the repair for low energy impact on thermoplastic composites as the samples recover their properties. At a first step of the study, the “repair” is made by reconsolidation on a thermoforming press but we could imagine a process in situ to reconsolidate the damaged parts.

Keywords: aerospace, automotive, composites, compression, damages, repair, structural applications, thermoplastic

Procedia PDF Downloads 304
192 Properties of Epoxy Composite Reinforced with Amorphous and Crystalline Silica from Rice Husk

Authors: Norul Hisham Hamid, Amir Affan, Ummi Hani Abdullah, Paridah Md. Tahir, Khairul Akmal Azhar, Rahmat Nawai, W. B. H. Wan Sulwani Izzati

Abstract:

The dimensional stability and static bending properties of epoxy composite reinforced with amorphous and crystalline silica were investigated. The amorphous and crystalline silica was obtained by the precipitation method from carbonisation process of the rice husk at a temperature of 600 °C and 1000 °C for 7 hours respectively. The epoxy resin was mixed with 5%, 10% and 15% concentrations of amorphous and crystalline silica. The mixture was stirred for 10 minutes and cured at 28 °C for 72 hours and oven dried at 80 °C for 72 hours. The scanning electron microscope image showed the silica sized of 10-30nm was obtained. The water absorption and thickness swelling of epoxy/amorphous silica composite was not significantly different with silica concentration ranged from 0.08% to 0.09% and 0.17% to 0.20% respectively. The maximum modulus of rupture (85 MPa) and modulus of elasticity (3284 MPa) were achieved for 10% silica concentration. For epoxy/crystalline silica composite; the water absorption and thickness swelling were also not significantly different with silica concentration, ranged from 0.08% to 0.11% and 0.16% to 0.18% respectively. The maximum modulus of rupture (47.9 MPa) and modulus of elasticity (2760 MPa) were achieved for 10% silica concentration. Overall, the water absorption and thickness swelling were almost identical for epoxy composite made from either amorphous or crystalline silica. The epoxy composite made from amorphous silica was stronger than crystalline silica.

Keywords: epoxy, composite, dimensional stability, static bending, silica

Procedia PDF Downloads 215
191 Epidemiological and Clinical Profile of Patients with Chorioamnionitis

Authors: Isabel Cristina Ortiz Trujillo, Lina Maria Martinez Sanchez, Felipe Hernández Restrepo, Daniel Gallego Gonzalez, Natalia Vargas Grisales, Camilo Andrés Agudelo Vélez

Abstract:

Chorioamnionitis, is a pregnancy infection, causes different fetal and maternal symptoms. Streptococcus agalactiae present in the normal vaginal microflora of some women, favouring its abnormal multiplication during pregnancy, causing perinatal morbidity and mortality. Objective. Describe the clinical and epidemiological profile of the patients with diagnosis of clinical chorioanmionitis. Methodology. Descriptive, cross-sectional study. The population was patients with diagnosis of clinical chorioanmionitis. The information was taken from the medical records. The research was approved by the Ethics Committee. We used the program SPSS ® version 17.0 (SPSS Inc; Chicago, Illinois, USA) for the information analysis, descriptive statistics were used. Results. 78 patients in total with clinical chorioamnionitis, with a mean age of 26.3 ±5, 8 years old, the 69.2% primigravid women. 2.6% of women had positive culture for Streptococcus agalactiae in urine sample during current pregnancy and 30.7% had received some kind of antibiotics during current pregnancy. The 57.7% had 37 to 40 weeks of gestation in the current pregnancy it was calculated more frequently by ultrasound (66.7% in first quarter, 11.5% in the second and 1.9% in the third). In a 60.3% way of termination of pregnancy was vaginal and a 35.9 percent were caesarean section. Among the women in the study, a 30.8% had premature rupture of membranes. Conclusion. The chorioamnionitis continues to be an important cause of antibiotic use during pregnancy or labour and the decision to do a caesarean, with highest percentage in pregnancies-preterm and preterm premature rupture of membranes.

Keywords: chorioamnionitis, Streptococcus agalactiae, pregnancy complications, infectious

Procedia PDF Downloads 422
190 Comparison of Visual Acuity Outcome and Complication after Phacoemulsification between Diabetic and Non-Diabetic Patients at Burapha University Hospital, Chonburi, Thailand

Authors: Luksanaporn Krungkraipetch

Abstract:

One hundred cataract patients with phacoemulsification were enrolled in the study to compare of visual acuity outcome and complication after phacoemulsification between diabetic and non-diabetic patients at Burapha University Hospital, Chonburi, Thailand. Fifty patients were diabetic (type II) group and 50 patients were non-diabetic group. All cases were operated by one doctor with the same pre-operative care, operation (phacoemulsification), and post-operative care. Visual acuity and complication after surgery were assessed after the operation for two years. There were no significant differences in demographic data between the two groups. The visual outcome values ≥ 2 lines and ≥ 20/40 had no significant differences between two groups after two years of surgery. The complication rate in diabetic group had cystoid macular edema 16%, rupture posterior capsule 8%, posterior capsule opacity 2%, uveitis 2 %, and 2% endophthalmitis. The non-diabetic group had cystoid macular edema 12%, rupture posterior capsule 8%, uveitis 2%, posterior capsule opacity 2%, and 2% wound leak. Comparison of visual acuity outcome and complication after phacoemulsification between diabetic and non-diabetic patients had no statistical significant differences between these two groups. It was found that cystoid macular edema was the most common complication in both groups and 10% of retinopathy progression was seen.

Keywords: cataract, visual acuity, cataract extraction, phacoemulsification, diabetic retinopathy

Procedia PDF Downloads 349
189 Effect of Cellular Water Transport on Deformation of Food Material during Drying

Authors: M. Imran Hossen Khan, M. Mahiuddin, M. A. Karim

Abstract:

Drying is a food processing technique where simultaneous heat and mass transfer take place from surface to the center of the sample. Deformation of food materials during drying is a common physical phenomenon which affects the textural quality and taste of the dried product. Most of the plant-based food materials are porous and hygroscopic in nature that contains about 80-90% water in different cellular environments: intercellular environment and intracellular environment. Transport of this cellular water has a significant effect on material deformation during drying. However, understanding of the scale of deformation is very complex due to diverse nature and structural heterogeneity of food material. Knowledge about the effect of transport of cellular water on deformation of material during drying is crucial for increasing the energy efficiency and obtaining better quality dried foods. Therefore, the primary aim of this work is to investigate the effect of intracellular water transport on material deformation during drying. In this study, apple tissue was taken for the investigation. The experiment was carried out using 1H-NMR T2 relaxometry with a conventional dryer. The experimental results are consistent with the understanding that transport of intracellular water causes cellular shrinkage associated with the anisotropic deformation of whole apple tissue. Interestingly, it is found that the deformation of apple tissue takes place at different stages of drying rather than deforming at one time. Moreover, it is found that the penetration rate of heat energy together with the pressure gradient between intracellular and intercellular environments is the responsible force to rupture the cell membrane.

Keywords: heat and mass transfer, food material, intracellular water, cell rupture, deformation

Procedia PDF Downloads 221
188 Electromyography Activity of the Lower Limb Muscles during Prostration and Squat Exercise

Authors: M. K. Mohd Safee, W. A. B. Wan Abas, F. Ibrahim, N. A. Abu Osman, N. A. Abdul Malik

Abstract:

This paper investigates the activity of the rectus femoris (RF) and biceps femoris (BF) in healthy subjects during salat (prostration) and specific exercise (squat exercise) using electromyography (EMG). A group of undergraduates aged between 19 to 25 years voluntarily participated in this study. The myoelectric activity of the muscles were recorded and analyzed. The finding indicated that there were contractions of the muscles during the salat and exercise with almost same EMG’s level. From the result, Wilcoxon’s Rank Sum test showed significant difference between prostration and squat exercise (p < 0.05) but the differences was very small; RF (8.63% MVC) and BF (11.43% MVC). Therefore, salat may be useful in strengthening exercise and also in rehabilitation programs for lower limb activities. This pilot study conducted initial research into the bio mechanical responses of human muscles in various positions of salat.

Keywords: electromyography, exercise, muscle, salat

Procedia PDF Downloads 711
187 Interrelationship between Quadriceps' Activation and Inhibition as a Function of Knee-Joint Angle and Muscle Length: A Torque and Electro and Mechanomyographic Investigation

Authors: Ronald Croce, Timothy Quinn, John Miller

Abstract:

Incomplete activation, or activation failure, of motor units during maximal voluntary contractions is often referred to as muscle inhibition (MI), and is defined as the inability of the central nervous system to maximally drive a muscle during a voluntary contraction. The purpose of the present study was to assess the interrelationship amongst peak torque (PT), muscle inhibition (MI; incomplete activation of motor units), and voluntary muscle activation (VMA) of the quadriceps’ muscle group as a function of knee angle and muscle length during maximal voluntary isometric contractions (MVICs). Nine young adult males (mean + standard deviation: age: 21.58 + 1.30 years; height: 180.07 + 4.99 cm; weight: 89.07 + 7.55 kg) performed MVICs in random order with the knee at 15, 55, and 95° flexion. MI was assessed using the interpolated twitch technique and was estimated by the amount of additional knee extensor PT evoked by the superimposed twitch during MVICs. Voluntary muscle activation was estimated by root mean square amplitude electromyography (EMGrms) and mechanomyography (MMGrms) of agonist (vastus medialis [VM], vastus lateralis [VL], and rectus femoris [RF]) and antagonist (biceps femoris ([BF]) muscles during MVICs. Data were analyzed using separate repeated measures analysis of variance. Results revealed a strong dependency of quadriceps’ PT (p < 0.001), MI (p < 0.001) and MA (p < 0.01) on knee joint position: PT was smallest at the most shortened muscle position (15°) and greatest at mid-position (55°); MI and MA were smallest at the most shortened muscle position (15°) and greatest at the most lengthened position (95°), with the RF showing the greatest change in MA. It is hypothesized that the ability to more fully activate the quadriceps at short compared to longer muscle lengths (96% contracted at 15°; 91% at 55°; 90% at 95°) might partly compensate for the unfavorable force-length mechanics at the more extended position and consequent declines in VMA (decreases in EMGrms and MMGrms muscle amplitude during MVICs) and force production (PT = 111-Nm at 15°, 217-NM at 55°, 199-Nm at 95°). Biceps femoris EMG and MMG data showed no statistical differences (p = 0.11 and 0.12, respectively) at joint angles tested, although there were greater values at the extended position. Increased BF muscle amplitude at this position could be a mechanism by which anterior shear and tibial rotation induced by high quadriceps’ activity are countered. Measuring and understanding the degree to which one sees MI and VMA in the QF muscle has particular clinical relevance because different knee-joint disorders, such ligament injuries or osteoarthritis, increase levels of MI observed and markedly reduced the capability of full VMA.

Keywords: electromyography, interpolated twitch technique, mechanomyography, muscle activation, muscle inhibition

Procedia PDF Downloads 347
186 Rupture in the Paradigm of the International Policy of Illicit Drugs in the Field of Public Health and within the Framework of the World Health Organization, 2001 to 2016

Authors: Emy Nayana Pinto, Denise Bomtempo Birche De Carvalho

Abstract:

In the present study, the harmful use of illicit drugs is seen as a public health problem and as one of the expressions of the social question, since its consequences fall mainly on the poorer classes of the population. This perspective is a counterpoint to the dominant paradigm on illicit drug policy at the global level, whose centrality lies within the criminal justice arena. The 'drug problem' is internationally combated through fragmented approaches that focus its actions on banning and criminalizing users. In this sense, the research seeks to answer the following key questions: What are the influences of the prohibitionism in the recommendations of the United Nations (UN), the World Health Organization (WHO), and the formulation of drug policies in member countries? What are the actors that have been provoking the prospect of breaking with the prohibitionist paradigm? What is the WHO contribution to the rupture with the prohibitionist paradigm and the displacement of the drug problem in the field of public health? The general objective of this work is to seek evidence from the perspective of rupture with the prohibitionist paradigm in the field of drugs policies at the global and regional level, through analysis of documents of the World Health Organization (WHO), between the years of 2001 to 2016. The research was carried out in bibliographical and documentary sources. The bibliographic sources contributed to the approach with the object and the theoretical basis of the research. The documentary sources served to answer the research questions and evidence the existence of the perspective of change in drug policy. Twenty-two documents of the UN system were consulted, of which fifteen had the contribution of the World Health Organization (WHO). In addition to the documents that directly relate to the subject of the research, documents from various agencies, programs, and offices, such as the Joint United Nations Program on HIV/AIDS (UNAIDS) and the United Nations Office on Drugs and Crime (UNODC), which also has drugs as the central or transversal theme of its performance. The results showed that from the 2000s it was possible to find in the literature review and in the documentary analysis evidence of the critique of the prohibitionist paradigm parallel to the construction of a new perspective for drug policy at the global level and the displacement of criminal justice approaches for the scope of public health, with the adoption of alternative and pragmatic interventions based on human rights, scientific evidence and the reduction of social damages and health by the misuse of illicit drugs.

Keywords: illicit drugs, international organizations, prohibitionism, public health, World Health Organization

Procedia PDF Downloads 156
185 Rupture Termination of the 1950 C. E. Earthquake and Recurrent Interval of Great Earthquake in North Eastern Himalaya, India

Authors: Rao Singh Priyanka, Jayangondaperumal R.

Abstract:

The Himalayan active fault has the potential to generate great earthquakes in the future, posing a biggest existential threat to humans in the Himalayan and adjacent region. Quantitative evaluation of accumulated and released interseismic strain is crucial to assess the magnitude and spatio-temporal variability of future great earthquakes along the Himalayan arc. To mitigate the destruction and hazards associated with such earthquakes, it is important to understand their recurrence cycle. The eastern Himalayan and Indo-Burman plate boundary systems offers an oblique convergence across two orthogonal plate boundaries, resulting in a zone of distributed deformation both within and away from the plate boundary and clockwise rotation of fault-bounded blocks. This seismically active region has poorly documented historical archive of the past large earthquakes. Thus, paleoseismologicalstudies confirm the surface rupture evidences of the great continental earthquakes (Mw ≥ 8) along the Himalayan Frontal Thrust (HFT), which along with the Geodetic studies, collectively provide the crucial information to understand and assess the seismic potential. These investigations reveal the rupture of 3/4th of the HFT during great events since medieval time but with debatable opinions for the timing of events due to unclear evidences, ignorance of transverse segment boundaries, and lack of detail studies. Recent paleoseismological investigations in the eastern Himalaya and Mishmi ranges confirms the primary surface ruptures of the 1950 C.E. great earthquake (M>8). However, a seismic gap exists between the 1714 C.E. and 1950 C.E. Assam earthquakes that did not slip since 1697 C.E. event. Unlike the latest large blind 2015 Gorkha earthquake (Mw 7.8), the 1950 C.E. event is not triggered by a large event of 1947 C.E. that occurred near the western edge of the great upper Assam event. Moreover, the western segment of the eastern Himalayadid not witness any surface breaking earthquake along the HFT for over the past 300 yr. The frontal fault excavations reveal that during the 1950 earthquake, ~3.1-m-high scarp along the HFT was formed due to the co-seismic slip of 5.5 ± 0.7 m at Pasighat in the Eastern Himalaya and a 10-m-high-scarp at a Kamlang Nagar along the Mishmi Thrust in the Eastern Himalayan Syntaxis is an outcome of a dip-slip displacement of 24.6 ± 4.6 m along a 25 ± 5°E dipping fault. This event has ruptured along the two orthogonal fault systems in the form of oblique thrust fault mechanism. Approx. 130 km west of Pasighat site, the Himebasti village has witnessed two earthquakes, the historical 1697 Sadiya earthquake, and the 1950 event, with a cumulative dip-slip displacement of 15.32 ± 4.69 m. At Niglok site, Arunachal Pradesh, a cumulative slip of ~12.82 m during at least three events since pre 19585 B.P. has produced ~6.2-m high scarp while the youngest scarp of ~2.4-m height has been produced during 1697 C.E. The site preserves two deformational events along the eastern HFT, providing an idea of last serial ruptures at an interval of ~850 yearswhile the successive surface rupturing earthquakes lacks in the Mishmi Range to estimate the recurrence cycle.

Keywords: paleoseismology, surface rupture, recurrence interval, Eastern Himalaya

Procedia PDF Downloads 84
184 Clinical Prediction Score for Ruptured Appendicitis In ED

Authors: Thidathit Prachanukool, Chaiyaporn Yuksen, Welawat Tienpratarn, Sorravit Savatmongkorngul, Panvilai Tangkulpanich, Chetsadakon Jenpanitpong, Yuranan Phootothum, Malivan Phontabtim, Promphet Nuanprom

Abstract:

Background: Ruptured appendicitis has a high morbidity and mortality and requires immediate surgery. The Alvarado Score is used as a tool to predict the risk of acute appendicitis, but there is no such score for predicting rupture. This study aimed to developed the prediction score to determine the likelihood of ruptured appendicitis in an Asian population. Methods: This study was diagnostic, retrospectively cross-sectional and exploratory model at the Emergency Medicine Department in Ramathibodi Hospital between March 2016 and March 2018. The inclusion criteria were age >15 years and an available pathology report after appendectomy. Clinical factors included gender, age>60 years, right lower quadrant pain, migratory pain, nausea and/or vomiting, diarrhea, anorexia, fever>37.3°C, rebound tenderness, guarding, white blood cell count, polymorphonuclear white blood cells (PMN)>75%, and the pain duration before presentation. The predictive model and prediction score for ruptured appendicitis was developed by multivariable logistic regression analysis. Result: During the study period, 480 patients met the inclusion criteria; of these, 77 (16%) had ruptured appendicitis. Five independent factors were predictive of rupture, age>60 years, fever>37.3°C, guarding, PMN>75%, and duration of pain>24 hours to presentation. A score > 6 increased the likelihood ratio of ruptured appendicitis by 3.88 times. Conclusion: Using the Ramathibodi Welawat Ruptured Appendicitis Score. (RAMA WeRA Score) developed in this study, a score of > 6 was associated with ruptured appendicitis.

Keywords: predictive model, risk score, ruptured appendicitis, emergency room

Procedia PDF Downloads 165
183 Determining Which Material Properties Resist the Tool Wear When Machining Pre-Sintered Zirconia

Authors: David Robert Irvine

Abstract:

In the dental restoration sector, there has been a shift to using zirconia. With the ever increasing need to decrease lead times to deliver restorations faster the zirconia is machined in its pre-sintered state instead of grinding the very hard sintered state. As with all machining, there is tool wear and while investigating the tooling used to machine pre-sintered zirconia it became apparent that the wear rate is based more on material build up and abrasion than it is on plastic deformation like conventional metal machining. It also came to light that the tool material can currently not be selected based on wear resistance, as there is no data. Different works have analysed the effect of the individual wear mechanism separately using similar if not the same material. In this work, the testing method used to analyse the wear was a modified from ISO 8688:1989 to use the pre-sintered zirconia and the cutting conditions used in dental to machine it. This understanding was developed through a series of tests based in machining operations, to give the best representation of the multiple wear factors that can occur in machining of pre-sintered zirconia such as 3 body abrasion, material build up, surface welding, plastic deformation, tool vibration and thermal cracking. From the testing, it found that carbide grades with low trans-granular rupture toughness would fail due to abrasion while those with high trans-granular rupture toughness failed due to edge chipping from build up or thermal properties. The results gained can assist the development of these tools and the restorative dental process. This work was completed with the aim of assisting in the selection of tool material for future tools along with a deeper understanding of the properties that assist in abrasive wear resistance and material build up.

Keywords: abrasive wear, cemented carbide, pre-sintered zirconia, tool wear

Procedia PDF Downloads 159
182 Comparison of Methodologies to Compute the Probabilistic Seismic Hazard Involving Faults and Associated Uncertainties

Authors: Aude Gounelle, Gloria Senfaute, Ludivine Saint-Mard, Thomas Chartier

Abstract:

The long-term deformation rates of faults are not fully captured by Probabilistic Seismic Hazard Assessment (PSHA). PSHA that use catalogues to develop area or smoothed-seismicity sources is limited by the data available to constraint future earthquakes activity rates. The integration of faults in PSHA can at least partially address the long-term deformation. However, careful treatment of fault sources is required, particularly, in low strain rate regions, where estimated seismic hazard levels are highly sensitive to assumptions concerning fault geometry, segmentation and slip rate. When integrating faults in PSHA various constraints on earthquake rates from geologic and seismologic data have to be satisfied. For low strain rate regions where such data is scarce it would be especially challenging. Faults in PSHA requires conversion of the geologic and seismologic data into fault geometries, slip rates and then into earthquake activity rates. Several approaches exist for translating slip rates into earthquake activity rates. In the most frequently used approach, the background earthquakes are handled using a truncated approach, in which earthquakes with a magnitude lower or equal to a threshold magnitude (Mw) occur in the background zone, with a rate defined by the rate in the earthquake catalogue. Although magnitudes higher than the threshold are located on the fault with a rate defined using the average slip rate of the fault. As high-lighted by several research, seismic events with magnitudes stronger than the selected magnitude threshold may potentially occur in the background and not only at the fault, especially in regions of slow tectonic deformation. It also has been known that several sections of a fault or several faults could rupture during a single fault-to-fault rupture. It is then essential to apply a consistent modelling procedure to allow for a large set of possible fault-to-fault ruptures to occur aleatory in the hazard model while reflecting the individual slip rate of each section of the fault. In 2019, a tool named SHERIFS (Seismic Hazard and Earthquake Rates in Fault Systems) was published. The tool is using a methodology to calculate the earthquake rates in a fault system where the slip-rate budget of each fault is conversed into rupture rates for all possible single faults and faultto-fault ruptures. The objective of this paper is to compare the SHERIFS method with one other frequently used model to analyse the impact on the seismic hazard and through sensibility studies better understand the influence of key parameters and assumptions. For this application, a simplified but realistic case study was selected, which is in an area of moderate to hight seismicity (South Est of France) and where the fault is supposed to have a low strain.

Keywords: deformation rates, faults, probabilistic seismic hazard, PSHA

Procedia PDF Downloads 64
181 Relation of Electromyography, Strength and Fatigue During Ramp Isometric Contractions

Authors: Cesar Ferreira Amorim, Tamotsu Hirata, Runer Augusto Marson

Abstract:

The purpose of this study was to determine the effect of strength ramp isometric contraction on changes in surface electromyography (sEMG) signal characteristics of the hamstrings muscles. All measurements were obtained from 20 healthy well trained healthy adults (age 19.5 ± 0.8 yrs, body mass 63.4 ± 1.5 kg, height: 1.65 ± 0.05 m). Subjects had to perform isometric ramp contractions in knee flexion with the force gradually increasing from 0 to 40% of the maximal voluntary contraction (MVC) in a 20s period. The root mean square (RMS) amplitude of sEMG signals obtained from the biceps femoris (caput longum) were calculated at four different strength levels (10, 20, 30, and 40% MVC) from the ramp isometric contractions (5s during the 20s task %MVC). The main results were a more pronounced increase non-linear in sEMG-RMS amplitude for the muscles. The protocol described here may provide a useful index for measuring of strength neuromuscular fatigue.

Keywords: biosignal, surface electromyography, ramp contractions, strength

Procedia PDF Downloads 483
180 Anaesthetic Management of Retropharyngeal Abscess in a Child

Authors: Sudha Puhal, Dr Rajmala Jaiswal

Abstract:

Retropharyngeal abscess occurs most commonly in children following acute upper respiratory tract and ear infection. Airway management in retropharyngeal abscess is an anesthetic challenge due to distortion of airway anatomy and the possibility of spontaneous rupture of abscess leading to aspiration or stridor due to laryngeal edema.. In this report we present a case of retropharyngeal abscess in a child, which was drained under general anaesthesia successfully without any complications.

Keywords: abscess, airway, difficult, retropharyngeal

Procedia PDF Downloads 145
179 Assessing the Suitability of South African Waste Foundry Sand as an Additive in Clay Masonry Products

Authors: Nthabiseng Portia Mahumapelo, Andre van Niekerk, Ndabenhle Sosibo, Nirdesh Singh

Abstract:

The foundry industry generates large quantities of solid waste in the form of waste foundry sand. The ever-increasing quantities of this type of industrial waste put pressure on land-filling space and its proper management has become a global concern. The South African foundry industry is not different when it comes to this solid waste generation. Utilizing the foundry waste sand in other applications has become an attractive avenue to deal with this waste stream. In the present paper, an evaluation was done on the suitability of foundry waste sand as an additive in clay masonry products. Purchased clay was added to the foundry waste sand sample in a 50/50 ratio. The mixture was named FC sample. The FC sample was mixed with water in a pan mixer until the mixture was consistent and suitable for extrusion. The FC sample was extruded and cut into briquettes. Water absorption, shrinkage and modulus of rupture tests were conducted on the resultant briquettes. Foundry waste sand and FC samples were respectively characterized mineralogically using X-Ray Diffraction, and the major and trace elements were determined using Inductively Coupled Plasma Optical Emission Spectroscopy. Adding purchased clay to the foundry waste sand positively influenced the workability of the test sample. Another positive characteristic was the low linear shrinkage, which indicated that products manufactured from the FC sample would not be susceptible to cracking. The water absorption values were acceptable and the unfired and fired strength values of the briquette’s samples were acceptable. In conclusion, tests showed that foundry waste sand can be used as an additive in masonry clay bricks, provided it is blended with good quality clay.

Keywords: foundry waste sand, masonry clay bricks, modulus of rupture, shrinkage

Procedia PDF Downloads 230