Search results for: patient safety
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6060

Search results for: patient safety

5610 A New Type Safety-Door for Earthquake Disaster Prevention: Part I

Authors: Daniel Y. Abebe, Jaehyouk Choi

Abstract:

From the past earthquake events, many people get hurt at the exit while they are trying to go out of the buildings because of the exit doors are unable to be opened. The door is not opened because it deviates from its the original position. The aim of this research is to develop and evaluate a new type safety door that keeps the door frame in its original position or keeps its edge angles perpendicular during and post-earthquake. The proposed door is composed of three components: outer frame joined to the wall, inner frame (door frame) and circular hollow section connected to the inner and outer frame which is used as seismic energy dissipating device.

Keywords: safety-door, earthquake disaster, low yield point steel, passive energy dissipating device, FE analysis

Procedia PDF Downloads 505
5609 Seafarers Safety, Watch-Keeping and Navigation

Authors: Sunday Moses Ojelabi

Abstract:

Safety is the protection of the crew, passenger and equipment itself, as well as those living and working near bodies of water, from hazardous situations. To assure safety, watch keeping is paramount because neglecting your watchkeeping can lead to hazardous situations. Navigation is the assignment of a sailor to a specific route on a vessel to operate. Navigation is the process of planning, managing, and directing a vessel safely to the desired destination with the aid of intense and efficient watch keeping. Safety, i,e, all measures done to preserve the welfare of marine life, maritime infrastructure, facilities, ships, offshore installations, crew, and passengers, as well as the preservation of navigation and the ease of maritime trade, are referred to as safety measures;. When it comes to health, the absence of a proper first aid kit will affect injured sailors and passengers. Not using goggles while shipping, ear muffs, etc., in the course of maintenance can be hazardous. Watchkeeping: i.e the specific dutiies assigned to a personnel in a vessel to see to its continous smooth functionality. Your lookout or watch officer [officer on navigational duty] must be active at all times in the course of duty. Navigation refers to the technique of precisely determining a craft or vehicle's position and directing its motion along a particular course. The seafarers are not being put through regular seminars, training, and orientations. In parts of West Africa, sailors go to school without being able to secure jobs until their papers expire. For that, they won’t go for another Standard Trainning Certification and Watch keeping for Seafarers to upgrade their certificate. In light of this, they are not familiar with the new vessels in the country, and for this, they can`t meet the safety, watch keeping, and navigation standards. Also, shipping companies and ship owners are being selfish by not putting the proper things needed onboard regarding safety, watchkeeping, and navigational equipment. The questions raised in these presentations are the breakdown of the safety activities, watch keeping effectiveness, and navigational accuracy. All safety and watch keeping regulations should be applied efficiently. The problem identified includes a lack of safety instruments onboard vessels in African waters. Also, inadequate proper watchkeeping due to the excess workload on the seafarers can lead to an improper lookout, which gives room to collision, hijacking, and piracy. The impact of this research is to inform African seafarers, shipping companies, and ship owners of the necessary information concerning the safety of their lives and that of their passengers, cargo, and equipment.

Keywords: standard of training, certification, watch keeping for seafarers, navigation, safety, watchkeeping

Procedia PDF Downloads 59
5608 Protection of Patients and Staff in External Beam Radiotherapy Using Linac in Kenya

Authors: Calvince Okome Odeny

Abstract:

There is a current action to increase radiotherapy services in Kenya. The National government of Kenya, in collaboration with the county governments, has embarked on building radiotherapy centers in all 47 regions of the country. As these new centers are established in Kenya, it has to be ensured that minimum radiation safety standards are in place prior to operation. For full implementation of this, it is imperative that more Research and training for regulators are done on radiation protection, and safety and national regulatory infrastructure is geared towards ensuring radiation protection and safety in all aspects of the use of external radiotherapy practices. The present work aims at reviewing the level of protection and safety for patients and staff during external beam radiotherapy using Linac in Kenya and provides relevant guidance to improve protection and safety. A retrospective evaluation was done to verify whether those occupationally exposed workers and patients are adequately protected from the harmful effect of radiation exposure during the treatment procedures using Linac. The project was experimental Research, also including an analysis of resource documents obtained from the literature and international organizations. The critical findings of the work revealed that the key elements of protection of occupationally exposed workers and patients include a comprehensive quality Management system governing all planned activities from siting, safety, and design of the Facility, construction, acceptance testing, commissioning, operation, and decommissioning of the Facility; Government empowering the Regulatory Authority to license Medical Linear facilities and to enforce the applicable regulations to ensure adequate protection; A comprehensive Radiation Protection and Safety program must be established to ensure adequate safety and protection of workers and patients during treatment planning and treatment delivery of patients and categories of staff associated with the Facility must be well educated and trained to perform professionally with a commitment to sound safety culture. Relevant recommendations from the findings are shared with the Medical Linear Accelerator facilities and the regulatory authority to provide guidance and continuous improvement of protection and safety to improve regulatory oversight.

Keywords: oncology, radiotherapy, protection, staff

Procedia PDF Downloads 56
5607 Assessment of the Impact of Traffic Safety Policy in Barcelona, 2010-2019

Authors: Lluís Bermúdez, Isabel Morillo

Abstract:

Road safety involves carrying out a determined and explicit policy to reduce accidents. In the city of Barcelona, through the Local Road Safety Plan 2013-2018, in line with the framework that has been established at the European and state level, a series of preventive, corrective and technical measures are specified, with the priority objective of reducing the number of serious injuries and fatalities. In this work, based on the data from the accidents managed by the local police during the period 2010-2019, an analysis is carried out to verify whether the measures established in the Plan to reduce the accident rate have had an effect or not and to what extent. The analysis focuses on the type of accident and the type of vehicles involved. Different count regression models have been fitted, from which it can be deduced that the number of serious and fatal victims of the accidents that have occurred in the city of Barcelona has been reduced as the measures approved by the authorities.

Keywords: accident reduction, count regression models, road safety, urban traffic

Procedia PDF Downloads 109
5606 Wrong Site Surgery Should Not Occur In This Day And Age!

Authors: C. Kuoh, C. Lucas, T. Lopes, I. Mechie, J. Yoong, W. Yoong

Abstract:

For all surgeons, there is one preventable but still highly occurring complication – wrong site surgeries. They can have potentially catastrophic, irreversible, or even fatal consequences on patients. With the exponential development of microsurgery and the use of advanced technological tools, the consequences of operating on the wrong side, anatomical part, or even person is seen as the most visible and destructive of all surgical errors and perhaps the error that is dreaded by most clinicians as it threatens their licenses and arouses feelings of guilt. Despite the implementation of the WHO surgical safety checklist more than a decade ago, the incidence of wrong-site surgeries remains relatively high, leading to tremendous physical and psychological repercussions for the clinicians involved, as well as a financial burden for the healthcare institution. In this presentation, the authors explore various factors which can lead to wrong site surgery – a combination of environmental and human factors and evaluate their impact amongst patients, practitioners, their families, and the medical industry. Major contributing factors to these “never events” include deviations from checklists, excessive workload, and poor communication. Two real-life cases are discussed, and systems that can be implemented to prevent these errors are highlighted alongside lessons learnt from other industries. The authors suggest that reinforcing speaking-up, implementing medical professional trainings, and higher patient’s involvements can potentially improve safety in surgeries and electrosurgeries.

Keywords: wrong side surgery, never events, checklist, workload, communication

Procedia PDF Downloads 167
5605 Safety of Built Infrastructure: Single Degree of Freedom Approach to Blast Resistant RC Wall Panels

Authors: Muizz Sanni-Anibire

Abstract:

The 21st century has witnessed growing concerns for the protection of built facilities against natural and man-made disasters. Studies in earthquake resistant buildings, fire, and explosion resistant buildings now dominate the arena. To protect people and facilities from the effects of the explosion, reinforced concrete walls have been designed to be blast resistant. Understanding the performance of these walls is a key step in ensuring the safety of built facilities. Blast walls are mostly designed using simple techniques such as single degree of freedom (SDOF) method, despite the increasing use of multi-degree of freedom techniques such as the finite element method. This study is the first stage of a continuous research into the safety and reliability of blast walls. It presents the SDOF approach applied to the analysis of a concrete wall panel under three representative bomb situations. These are motorcycle 50 kg, car 400kg and also van with the capacity of 1500 kg of TNT explosive.

Keywords: blast wall, safety, protection, explosion

Procedia PDF Downloads 247
5604 More Precise: Patient-Reported Outcomes after Stroke

Authors: Amber Elyse Corrigan, Alexander Smith, Anna Pennington, Ben Carter, Jonathan Hewitt

Abstract:

Background and Purpose: Morbidity secondary to stroke is highly heterogeneous, but it is important to both patients and clinicians in post-stroke management and adjustment to life after stroke. The consideration of post-stroke morbidity clinically and from the patient perspective has been poorly measured. The patient-reported outcome measures (PROs) in morbidity assessment help improve this knowledge gap. The primary aim of this study was to consider the association between PRO outcomes and stroke predictors. Methods: A multicenter prospective cohort study assessed 549 stroke patients at 19 hospital sites across England and Wales during 2019. Following a stroke event, demographic, clinical, and PRO measures were collected. Prevalence of morbidity within PRO measures was calculated with associated 95% confidence intervals. Predictors of domain outcome were calculated using a multilevel generalized linear model. Associated P -values and 95% confidence intervals are reported. Results: Data were collected from 549 participants, 317 men (57.7%) and 232 women (42.3%) with ages ranging from 25 to 97 (mean 72.7). PRO morbidity was high post-stroke; 93.2% of the cohort report post-stroke PRO morbidity. Previous stroke, diabetes, and gender are associated with worse patient-reported outcomes across both the physical and cognitive domains. Conclusions: This large-scale multicenter cohort study illustrates the high proportion of morbidity in PRO measures. Further, we demonstrate key predictors of adverse outcomes (Diabetes, previous stroke, and gender) congruence with clinical predictors. The PRO has been demonstrated to be an informative and useful stroke when considering patient-reported outcomes and has wider implications for considerations of PROs in clinical management. Future longitudinal follow-up with PROs is needed to consider association of long-term morbidity.

Keywords: morbidity, patient-reported outcome, PRO, stroke

Procedia PDF Downloads 112
5603 Safety Analysis and Accident Modeling of Transportation in Srinagar City

Authors: Adinarayana Badveeti, Mohammad Shafi Mir

Abstract:

In Srinagar city, in India, road safety is an important aspect that creates ecological balance and social well being. A road accident creates a situation that leaves behind distress, sorrow, and sufferings. Therefore identification of causes of road accidents becomes highly essential for adopting necessary preventive measures against a critical event. The damage created by road accidents to large extent is unrepairable and therefore needs attention to eradicate this continuously increasing trend of awful 'epidemic'. Road accident in India is among the highest in the world, with at least approximately 142.000 people killed each year on the road. Kashmir region is an ecologically sensitive place but lacks necessary facilities and infrastructure regarding road transportation, ultimately resulting in the critical event-road accidents creating a major problem for common people in the region. The objective of this project is to study the safety aspect of Srinagar City and also model the accidents with different aspect that causes accidents and also to suggest the possible remedies for lessening/eliminating the road accidents.

Keywords: road safety, road accident, road infrastructure, accident modeling

Procedia PDF Downloads 234
5602 Traffic Safety and Risk Assessment Model by Analysis of Questionnaire Survey: A Case Study of S. G. Highway, Ahmedabad, India

Authors: Abhijitsinh Gohil, Kaushal Wadhvaniya, Kuldipsinh Jadeja

Abstract:

Road Safety is a multi-sectoral and multi-dimensional issue. An effective model can assess the risk associated with highway safety. A questionnaire survey is very essential to identify the events or activities which are causing unsafe condition for traffic on an urban highway. A questionnaire of standard questions including vehicular, human and infrastructure characteristics can be made. Responses from the age wise group of road users can be taken on field. Each question or an event holds a specific risk weightage, which contributes in creating an inappropriate and unsafe flow of traffic. The probability of occurrence of an event can be calculated from the data collected from the road users. Finally, the risk score can be calculated by considering the risk factor and the probability of occurrence of individual event and addition of all risk score for the individual event will give the total risk score of a particular road. Standards for risk score can be made and total risk score can be compared with the standards. Thus road can be categorized based on risk associated and traffic safety on it. With this model, one can assess the need for traffic safety improvement on a given road, and qualitative data can be analysed.

Keywords: probability of occurrence, questionnaire, risk factor, risk score

Procedia PDF Downloads 324
5601 The Two Layers of Food Safety and GMOs in the Hungarian Agricultural Law

Authors: Gergely Horváth

Abstract:

The study presents the complexity of food safety dividing it into two layers. Beyond the basic layer of requirements, there is a more demanding higher level linked with quality and purity aspects. It would be important to give special prominence to both layers, given that massive illnesses are caused by foods even though officially licensed. Then the study discusses an exciting safety challenge stemming from the risks of genetically modified organisms (GMOs). Furthermore, it features legal case examples that illustrate how certain liability questions are solved or not yet decided in connection with the production of genetically modified crops. In addition, a special kind of land grabbing, more precisely land grabbing from non-GMO farming systems can also be noticed as well as a new phenomenon eroding food sovereignty. Coexistence, the state where organic, conventional, and GM farming systems are standing alongside each other is an unsuitable experiment that cannot be successful, because of biophysical reasons (such as cross-pollination). Agricultural and environmental lawyers both try to find the optimal solution. Agri-environmental measures are introduced as a special subfield of law maintaining also food safety. The important steps of agri-environmental legislation are aiming at the protection of natural values, the environmental media and strengthening food safety as well, practically the quality of agricultural products intended for human consumption. The major findings of the study focus on searching for the appropriate approach capable of solving the security and safety problems of food production. The most interesting concepts of the Hungarian national and EU food law legislation are analyzed in more detail with descriptive, analytic and comparative methods.

Keywords: food law, food safety, food security, GMO, Genetically Modified Organisms, agri-environmental measures

Procedia PDF Downloads 420
5600 Design and Implementation of a Wearable Artificial Kidney Prototype for Home Dialysis

Authors: R. A. Qawasma, F. M. Haddad, H. O. Salhab

Abstract:

Hemodialysis is a life-preserving treatment for a number of patients with kidney failure. The standard procedure of hemodialysis is three times a week during the hemodialysis procedure, the patient usually suffering from many inconvenient, exhausting feeling and effect on the heart and cardiovascular system are the most common signs. This paper provides a solution to reduce the previous problems by designing a wearable artificial kidney (WAK) taking in consideration a minimization the size of the dialysis machine. The WAK system consists of two circuits: blood circuit and dialysate circuit. The blood from the patient is filtered in the dialyzer before returning back to the patient. Several parameters using an advanced microcontroller and array of sensors. WAK equipped with visible and audible alarm system to aware the patients if there is any problem.

Keywords: artificial kidney, home dialysis, renal failure, wearable kidney

Procedia PDF Downloads 215
5599 The Nursing Experience in a Stroke Patient after Lumbar Surgery at Surgical Intensive Care Unit

Authors: Yu-Chieh Chen, Kuei-Feng Shen, Chia-Ling Chao

Abstract:

The purpose of this report was to present the nursing experience and case of an unexpected cerebellar hemorrhagic stroke with acute hydrocephalus patient after lumbar spine surgery. The patient had been suffering from an emergent external ventricular drainage and stayed in the Surgical Intensive Care Unit from July 8, 2016, to July 22, 2016. During the period of the case, the data were collected for attendance, evaluation, observation, interview, searching medical record, etc. An integral evaluation of the patient's physiological 'psychological' social and spiritual states was also noted. The author noticed the following major nursing problems including ineffective cerebral perfusion 'physical activity dysfunction' family resource preparation for disability. The author provided nursing care to maintain normal intracranial pressure, along with a well-therapeutic relationship and applied interdisciplinary medical/nursing team to draft an individualized and appropriate nursing plan for them to face the psychosocial impact of the patient disabilities. We also actively participated in the rehabilitation treatments to improve daily activity and confidence. This was deemed necessary to empower them to a more positive attitude in the future.

Keywords: family resourace preparation inability, hemorrhagic sroke, ineffective tissue cerebral perfusion, lumbar spine surgery

Procedia PDF Downloads 107
5598 Design and Development of a Safety Equipment and Accessory for Bicycle Users

Authors: Francine Siy, Stephen Buñi

Abstract:

Safety plays a significant role in everyone’s life on a day-to-day basis. We wish ourselves and our loved ones their safety as we all venture out on our daily commute. The road is undeniably dangerous and unpredictable, with abundant traffic collisions and pedestrians experiencing various injuries. For bicycle users, the risk of accidents is even more exacerbated, and injuries may be severe. Even when cyclists try their best to be safe and protected, the possibility of encountering danger is always there. Despite being equipped with protective gear, safety is never guaranteed. Cyclists often settle for helmets and standard reflector vests to establish a presence on the road. There are different types of vests available, depending on the profession. However, traditional reflector vests, mostly seen on construction workers and traffic enforcers, were not designed for riders and their protection from injuries. With insufficient protection for riders, they need access to ergonomically designed equipment and accessories that suit the riders and cater to their needs. This research aimed to offer a protective vest with safety features for riders that is comfortable, effective, durable, and intuitive. This sheds light and addresses the safety of the biker population, which continuously grows through the years. The product was designed and developed by gathering data and using the cognitive mapping method to ensure that all qualitative and quantitative data were considered in this study to improve other existing products that do not have the proper design considerations. It is known that available equipment for cyclists is often sold separately or lacks the safety features for cyclists traversing open roads. Each safety feature like the headlights, reflectors, signal or rear lights, zipper pouch, body camera attachment, and wireless remote control all play a particular role in helping cyclists embark on their daily commute. These features aid in illumination, visibility, easy maneuvering, convenience, and security, allowing cyclists to go for a safer ride that is of use throughout the day. The product is designed and produced effectively and inexpensively without sacrificing the quality and purpose of its usage.

Keywords: bicycle accessory, protective gear, safety, transport, visibility

Procedia PDF Downloads 69
5597 Evaluation and Analysis of the Regulations of Health and Safety in the Construction Industry: A Case of Study in Skikda, Algeria

Authors: Khorief Ouissem, Sassi Boudmagh Souad, Mahimoud Aissa

Abstract:

The health and safety problem in the construction companies has been a major subject of research in Algeria for many years. The latest statistics of the Algerian National Social Security Fund (CNAS) shows that a third of accidents recorded at the national level are originated from construction activities. It is becoming increasingly essential and urgent to investigate and address its causes in order to find measures to overcome the deficiencies in this area. Thus, this paper takes in investigating this problem through a study conducted in the city of Skikda, Algeria. The study was carried out through questionnaire where twenty construction companies were taking into consideration. First, the study identifies the regulations and the laws related to the health and safety in the construction sector in Algeria. Then it goes on to assess and evaluate the implementation of the identified regulations in the companies selected. The result of the assessment indicates that the majority of the construction companies considered do not meet the health and safety standards and regulations. To extract the main causes of the failure of the system to control this industry, the observations and the evaluation were analyzed using the 5M or Ichikawa diagram method. This method is based on identifying the causes of the problem in terms of purpose, the list of potential causes for families. These families often correspond to 5M (Labor, Material, Methods, Middle, and Management). Finally, having identified the primary motives, the present authors propose a list of actions to move towards a more controlled and effective health and safety system for the construction industry.

Keywords: health and safety, construction industry, performance measurement, Algeria

Procedia PDF Downloads 316
5596 Magnitude and Outcome of Resuscitation Activities at Rwanda Military Hospital for the Period of April 2013-September 2013

Authors: Auni Idi Muhire

Abstract:

Background: Prior to April 2012, resuscitations were often ineffective resulting in poor patient outcomes. An initiative was implemented at Rwanda Military Hospital (RMH) to review root causes and plan strategies to improve patient outcomes. An interdisciplinary committee was developed to review this problem. Purpose: Analyze the frequency, obstacles, and outcome of patient resuscitation following cardiac and/or respiratory arrest. Methods: A form was developed to allow recording of all actions taken during resuscitation including response times, staff present, and equipment and medications used. Results:-The patient population requiring the most resuscitation effort are the intensive care patients, most frequently the neonatal the intensive care patients (42.8%) -Despite having trained staff representatives, not all resuscitations follow protocol -Lack of compliance with drug administration guidelines was noted, particularly in initiating use of drugs despite the drug being available (59%). Lesson Learned: Basic Life Support training for interdisciplinary staff resulted in more effective response to cardiac and/or respiratory arrest at RMH. Obstacles to effective resuscitation included number of staff, knowledge and skill level of staff, availability of appropriate equipment and medications, staff communication, and patient Do not Attempt Resuscitation (DNR) status.

Keywords: resuscitation, case analysis of knowledge versus practice, intensive care, critical care

Procedia PDF Downloads 255
5595 The Success Rate of Anterior Crowding Orthodontic Treatment Using Removable Appliances

Authors: Belly Yordan

Abstract:

Orthodontic treatment can be done by using the fix and removable orthodontic appliance. The success of treatment depends on the patient’s age, the type of malocclusion, treatment of space discrepancy, patient’s oral hygiene, operator skills, and patient cooperation. This case report was aimed to show the success of orthodontic treatment in patients with skeletal class I relationship, class I angle dental malocclusion with anterior crowding and rotation by using a removable appliance with modification. The removable appliance used is standard with removable plate components such as passive clasp (Adam’s hook clasp) accompanied with some active clasps (labial bow, some springs, etc.). A button is used as an additional tool or combined with other tools to correct tooth in rotated position. The results obtained by the success of treatments which is shown in pre and post-treatment photos, the overjet was reduced, the arch form became normal, the tooth malposition became normal, and rotation was corrected. Facial profile appearance of the patient is getting better, and the dental coordination also became better. This case report is to prove that treatment with the removable appliance is quite successful with the robust wearing of appropriate retainers.

Keywords: success rate, anterior crowding, orthodontic treatment, removable appliances

Procedia PDF Downloads 155
5594 Proposal to Increase the Efficiency, Reliability and Safety of the Centre of Data Collection Management and Their Evaluation Using Cluster Solutions

Authors: Martin Juhas, Bohuslava Juhasova, Igor Halenar, Andrej Elias

Abstract:

This article deals with the possibility of increasing efficiency, reliability and safety of the system for teledosimetric data collection management and their evaluation as a part of complex study for activity “Research of data collection, their measurement and evaluation with mobile and autonomous units” within project “Research of monitoring and evaluation of non-standard conditions in the area of nuclear power plants”. Possible weaknesses in existing system are identified. A study of available cluster solutions with possibility of their deploying to analysed system is presented.

Keywords: teledosimetric data, efficiency, reliability, safety, cluster solution

Procedia PDF Downloads 497
5593 Microbiological Quality and Safety of Meatball Sold in Payakumbuh City, West Sumatra, Indonesia

Authors: Ferawati, H. Purwanto, Y. F. Kurnia, E. Purwati

Abstract:

The aim of this study was to evaluate the microbiological quality and safety of meatball obtained from five different manufacturers around Payakumbuh City, West Sumatra, Indonesia. Microbiological analysis of meatball sample resulted in aerobic plate count range from 7 log CFU/gr to 8.623 log CFU/gr, respectively. Total coliform ranges from 1.041 log Most Probable Number (MPN)/gr to 3.380 log MPN/gr, respectively. Chemical analysis of meatball sample consisted of borax and formalin content. The result of qualitative detection of borax and formalin content on all meatball samples were not detected. Thus, it remains essential to include the significance of effective hygiene practices as an important safety measure in consumer education programmes.

Keywords: borax, formalin, meatball, microbiological quality

Procedia PDF Downloads 270
5592 Colour Recognition Pen Technology in Dental Technique and Dental Laboratories

Authors: M. Dabirinezhad, M. Bayat Pour, A. Dabirinejad

Abstract:

Recognition of the color spectrum of the teeth plays a significant role in the dental laboratories to produce dentures. Since there are various types and colours of teeth for each patient, there is a need to specify the exact and the most suitable colour to produce a denture. Usually, dentists utilize pallets to identify the color that suits a patient based on the color of the adjacent teeth. Consistent with this, there can be human errors by dentists to recognize the optimum colour for the patient, and it can be annoying for the patient. According to the statistics, there are some claims from the patients that they are not satisfied by the colour of their dentures after the installation of the denture in their mouths. This problem emanates from the lack of sufficient accuracy during the colour recognition process of denture production. The colour recognition pen (CRP) is a technology to distinguish the colour spectrum of the intended teeth with the highest accuracy. CRP is equipped with a sensor that is capable to read and analyse a wide range of spectrums. It is also connected to a database that contains all the spectrum ranges, which exist in the market. The database is editable and updatable based on market requirements. Another advantage of this invention can be mentioned as saving time for the patients since there is no need to redo the denture production in case of failure on the first try.

Keywords: colour recognition pen, colour spectrum, dental laboratory, denture

Procedia PDF Downloads 179
5591 The Effectiveness of Synthesizing A-Pillar Structures in Passenger Cars

Authors: Chris Phan, Yong Seok Park

Abstract:

The Toyota Camry is one of the best-selling cars in America. It is economical, reliable, and most importantly, safe. These attributes allowed the Camry to be the trustworthy choice when choosing dependable vehicle. However, a new finding brought question to the Camry’s safety. Since 1997, the Camry received a “good” rating on its moderate overlap front crash test through the Insurance Institute of Highway Safety. In 2012, the Insurance Institute of Highway Safety introduced a frontal small overlap crash test into the overall evaluation of vehicle occupant safety test. The 2012 Camry received a “poor” rating on this new test, while the 2015 Camry redeemed itself with a “good” rating once again. This study aims to find a possible solution that Toyota implemented to reduce the severity of a frontal small overlap crash in the Camry during a mid-cycle update. The purpose of this study is to analyze and evaluate the performance of various A-pillar shapes as energy absorbing structures in improving passenger safety in a frontal crash. First, A-pillar structures of the 2012 and 2015 Camry were modeled using CAD software, namely SolidWorks. Then, a crash test simulation using ANSYS software, was applied to the A-pillars to analyze the behavior of the structures in similar conditions. Finally, the results were compared to safety values of cabin intrusion to determine the crashworthy behaviors of both A-pillar structures by measuring total deformation. This study highlights that it is possible that Toyota improved the shape of the A-pillar in the 2015 Camry in order to receive a “good” rating from the IIHS safety evaluation once again. These findings can possibly be used to increase safety performance in future vehicles to decrease passenger injury or fatality.

Keywords: A-pillar, Crashworthiness, Design Synthesis, Finite Element Analysis

Procedia PDF Downloads 97
5590 Evaluation of Longitudinal and Hoop Stresses and a Critical Study of Factor of Safety (FoS) in Design of a Glass-Fiber Pressure Vessel

Authors: Zainul Huda, Mohammed Hani Ajani

Abstract:

The design, manufacture, and operation of thin-walled pressure vessels must be based on maximum safe operating pressure and an adequate factor of safety (FoS). This research paper first reports experimental evaluation of longitudinal and hoops stresses based on working pressure as well as maximum pressure; and then includes a critical study of factor of safety (FoS) in the design of a glass fiber pressure vessel. Experimental work involved the use of measuring instruments and the readings from pressure gauges. Design calculations involved the computations of design stress and FoS; the latter was based on breaking strength of 55 MPa for the glass fiber (pressure-vessel material). The experimentally determined FoS value has been critically compared with the general FoS allowed in the design of glass fiber pressure vessels.

Keywords: thin-walled pressure vessel, hoop stress, longitudinal stress, factor of safety (FoS), fiberglass

Procedia PDF Downloads 467
5589 Evaluation of Longitudinal and Hoops Stresses and a Critical Study of Factor of Safety (Fos) in the Design of a Glass-Fiber Pressure Vessel

Authors: Zainul Huda, Mohammad Hani Ajani

Abstract:

The design, manufacture, and operation of thin-walled pressure vessels must be based on maximum safe operating pressure and an adequate factor of safety (FoS). This research paper first reports experimental evaluation of longitudinal and hoops stresses based on working pressure as well as maximum pressure; and then includes a critical study of factor of safety (FoS) in the design of a glass fiber pressure vessel. Experimental work involved the use of measuring instruments and the readings from pressure gauges. Design calculations involved the computations of design stress and FoS; the latter was based on breaking strength of 55 MPa for the glass fiber (pressure-vessel material). The experimentally determined FoS value has been critically compared with the general FoS allowed in the design of glass fiber pressure vessels.

Keywords: thin-walled pressure vessel, hoop stress, longitudinal stress, factor of safety (FoS), fiberglass

Procedia PDF Downloads 474
5588 Critical Evaluation of Occupational Health and Safety Challenges Facing the Construction Sector in the UK and Developing Anglophone West African Countries, Particularly the Gambia

Authors: Bintou Jobe

Abstract:

The construction sector, both in the United Kingdom (UK) and developing Anglophone West African countries, specifically The Gambia, is facing significant health and safety challenges. While the UK has established legislation and regulations to support Occupational Health and Safety (OHS) in the industry, the same level of support is lacking in developing countries. The significance of this review is to assess the extent and effectiveness of OHS legislation and regulatory reform in the construction industry, with a focus on understanding the challenges faced by both the UK and developing Anglophone West African countries. It aims to highlight the benefits of implementing an OHS management system, specifically ISO 45001. This study uses a literature review approach, synthesizing publications from the past decade and identifying common themes and best practices related to Occupational Health and Safety in the construction industry. Findings were analysed, compared, and conclusions and recommendations were drawn after developing research questions and addressing them. This comprehensive review of the literature allows for a detailed understanding of the challenges faced by the industry in both contexts. The findings of the study indicate that while the UK has established robust health and safety legislation, many UK construction companies have not fully met the standards outlined in ISO 45001. These challenges faced by the UK include poor data management, inadequate communication of best practices, insufficient training, and a lack of safety culture mirroring those observed in the developing Anglophone countries. Therefore, compliance with OHS management systems has been shown to yield benefits, including injury prevention and centralized health and safety documentation. In conclusion, the effectiveness of OHS legislation for developing Anglophone West African countries should consider the positive impact experienced by the UK. The implementation of ISO 45001 can serve as a benchmark standard and potentially inform recommendations for developing countries. The selection criteria for literature include search keywords and phrases, such as occupational health and safety challenges, The Gambia, developing countries management systems, ISO 45001, and impact and effectiveness of OHS legislation. The literature was sourced from Google Scholar, the UK Health and Safety Executive websites, and Google Advanced Search.

Keywords: ISO 45001, developing countries, occupational health and safety, UK

Procedia PDF Downloads 68
5587 Mecano-Reliability Approach Applied to a Water Storage Tank Placed on Ground

Authors: Amar Aliche, Hocine Hammoum, Karima Bouzelha, Arezki Ben Abderrahmane

Abstract:

Traditionally, the dimensioning of storage tanks is conducted with a deterministic approach based on partial coefficients of safety. These coefficients are applied to take into account the uncertainties related to hazards on properties of materials used and applied loads. However, the use of these safety factors in the design process does not assure an optimal and reliable solution and can sometimes lead to a lack of robustness of the structure. The reliability theory based on a probabilistic formulation of constructions safety can respond in an adapted manner. It allows constructing a modelling in which uncertain data are represented by random variables, and therefore allows a better appreciation of safety margins with confidence indicators. The work presented in this paper consists of a mecano-reliability analysis of a concrete storage tank placed on ground. The classical method of Monte Carlo simulation is used to evaluate the failure probability of concrete tank by considering the seismic acceleration as random variable.

Keywords: reliability approach, storage tanks, monte carlo simulation, seismic acceleration

Procedia PDF Downloads 288
5586 Development of Patient Satisfaction Questionnaire for Diabetes Management in Thailand and Lao People Democratic Republic

Authors: Phoutsathaphone Sibounheuang, Phayom Sookaneknun Olson, Chanuttha Ploylearmsang, Santiparp Sookaneknun, Chanthanom Manithip

Abstract:

Patient satisfaction is an outcome that can be measured and used to improve diabetes care and management. There are limited instruments for assessing patient satisfaction covering the whole process of diabetes management. In this study, the questionnaire was developed with items pooled from a systematic review of qualitative studies of patients’ and healthcare providers’ perspectives in diabetes management. The questionnaire consists of 11 domains with 45 items. The Thai version was translated to Lao and then checked by back-translating it into Thai. We tested the questionnaire on 150 diabetes patients in Thailand and 150 in Lao People Democratic Republic (PDR). Validity was performed by factor analysis and Pearson correlation. Internal consistency reliability was estimated by calculating Cronbach’s alpha. The study was approved by the Mahasarakham University Ethics Committee, and the National Ethics Committee for Health Research, Lao PDR. The Thai and Lao versions showed the construct validity by principal component analysis. This consisted of 11 domains which account for 71.23% of the variance (Thai version) and 71.66% of the variance (Lao version) in the total patient satisfaction scores. The Kaiser-Meyer-Olkin (KMO) measures were 0.85 for the Thai version and 0.75 for the Lao version. The Bartlett tests of sphericity of both versions were significant (p < 0.001). The factor loadings of all items in both versions were > 0.40. The convergent validity of the Thai and Lao versions was 93.63% and 79.54% respectively. The discriminant validity for the Thai and Lao versions was 92.68% and 88.68% respectively. Cronbach’s alpha was 0.95 in both versions. The Patient Satisfaction Questionnaire (PSQ) in both versions had acceptable properties. This study has yielded evidence supporting the validity and reliability of both versions.

Keywords: construct validity, diabetes management, patient satisfaction, questionnaire development, reliability

Procedia PDF Downloads 123
5585 Using Knowledge Management and Visualisation Concepts to Improve Patients and Hospitals Staff Workflow

Authors: A. A. AlRasheed, A. Atkins, R. Campion

Abstract:

This paper focuses on using knowledge management and visualisation concepts to improve the patients and hospitals employee’s workflow. Hospitals workflow is a complex and complicated process and poor patient flow can put both patients and a hospital’s reputation at risk, and can threaten the facility’s financial sustainability. Healthcare leaders are under increased pressure to reduce costs while maintaining or increasing patient care standards. In this paper, a framework is proposed to help improving patient experience, staff satisfaction, and operational efficiency across hospitals by using knowledge management based visualisation concepts. This framework is using real-time visibility to track and monitor location and status of patients, staff, rooms, and medical equipment.

Keywords: knowledge management, improvements, visualisation, workflow

Procedia PDF Downloads 245
5584 IOT Based Process Model for Heart Monitoring Process

Authors: Dalyah Y. Al-Jamal, Maryam H. Eshtaiwi, Liyakathunisa Syed

Abstract:

Connecting health services with technology has a huge demand as people health situations are becoming worse day by day. In fact, engaging new technologies such as Internet of Things (IOT) into the medical services can enhance the patient care services. Specifically, patients suffering from chronic diseases such as cardiac patients need a special care and monitoring. In reality, some efforts were previously taken to automate and improve the patient monitoring systems. However, the previous efforts have some limitations and lack the real-time feature needed for chronic kind of diseases. In this paper, an improved process model for patient monitoring system specialized for cardiac patients is presented. A survey was distributed and interviews were conducted to gather the needed requirements to improve the cardiac patient monitoring system. Business Process Model and Notation (BPMN) language was used to model the proposed process. In fact, the proposed system uses the IOT Technology to assist doctors to remotely monitor and follow-up with their heart patients in real-time. In order to validate the effectiveness of the proposed solution, simulation analysis was performed using Bizagi Modeler tool. Analysis results show performance improvements in the heart monitoring process. For the future, authors suggest enhancing the proposed system to cover all the chronic diseases.

Keywords: IoT, process model, remote patient monitoring system, smart watch

Procedia PDF Downloads 315
5583 Knowledge-Attitude-Practice Survey Regarding High Alert Medication in a Teaching Hospital in Eastern India

Authors: D. S. Chakraborty, S. Ghosh, A. Hazra

Abstract:

Objective: Medication errors are a reality in all settings where medicines are prescribed, dispensed and used. High Alert Medications (HAM) are those that bear a heightened risk of causing significant patient harm when used in error. We conducted a knowledge-attitude-practice survey, among residents working in a teaching hospital, to assess the ground situation with regard to the handling of HAM. Methods: We plan to approach 242 residents among the approximately 600 currently working in the hospital through purposive sampling. Residents in all disciplines (clinical, paraclinical and preclinical) are being targeted. A structured questionnaire that has been pretested on 5 volunteer residents is being used for data collection. The questionnaire is being administered to residents individually through face-to-face interview, by two raters, while they are on duty but not during rush hours. Results: Of the 156 residents approached so far, data from 140 have been analyzed, the rest having refused participation. Although background knowledge exists for the majority of respondents, awareness levels regarding HAM are moderate, and attitude is non-uniform. The number of respondents correctly able to identify most ( > 80%) HAM in three common settings– accident and emergency, obstetrics and intensive care unit are less than 70%. Several potential errors in practice have been identified. The study is ongoing. Conclusions: Situation requires corrective action. There is an urgent need for improving awareness regarding HAM for the sake of patient safety. The pharmacology department can take the lead in designing awareness campaign with support from the hospital administration.

Keywords: high alert medication, medication error, questionnaire, resident

Procedia PDF Downloads 111
5582 The Untreated Burden of Parkinson’s Disease: A Patient Perspective

Authors: John Acord, Ankita Batla, Kiran Khepar, Maude Schmidt, Charlotte Allen, Russ Bradford

Abstract:

Objectives: Despite the availability oftreatment options, Parkinson’s disease (PD) continues to impact heavily on a patient’s quality of life (QoL), as many symptoms that bother the patient remain unexplored and untreated in clinical settings. The aims of this research were to understand the burden of PDsymptoms from a patient perspective, particularly those which are the most persistent and debilitating, and to determine if current treatments and treatment algorithms adequately focus on their resolution. Methods: A13-question, online, patient-reported survey was created based on the MDS-Unified Parkinson’s Disease Rating Scale (MDS-UPDRS)and symptoms listed on Parkinson’s Disease Patient Advocacy Groups websites, and then validated by 10 Parkinson’s patients. In the survey, patients were asked to choose both their most common and their most bothersome symptoms, whether they had received treatment for those and, if so, had it been effective in resolving those symptoms. Results: The most bothersome symptoms reported by the 111 participants who completed the survey were sleep problems (61%), feeling tired (56%), slowness of movements (54%), and pain in some parts of the body (49%). However, while 86% of patients reported receiving dopamine or dopamine like drugs to treat their PD, far fewer reported receiving targeted therapies for additional symptoms. For example, of the patients who reported having sleep problems, only 33% received some form of treatment for this symptom. This was also true for feeling tired (30% received treatment for this symptom), slowness of movements (62% received treatment for this symptom), and pain in some parts of the body (61% received treatment for this symptom). Additionally, 65% of patients reported that the symptoms they experienced were not adequately controlled by the treatments they received, and 9% reported that their current treatments had no effect on their symptoms whatsoever. Conclusion: The survey outcomes highlight that the majority of patients involved in the study received treatment focused on their disease, however, symptom-based treatments were less well represented. Consequently, patient-reported symptoms such as sleep problems and feeling tired tended to receive more fragmented intervention than ‘classical’ PD symptoms, such as slowness of movement, even though they were reported as being amongst the most bothersome symptoms for patients. This research highlights the need to explore symptom burden from the patient’s perspective and offer Customised treatment/support for both motor and non-motor symptoms maximize patients’ quality of life.

Keywords: survey, patient reported symptom burden, unmet needs, parkinson's disease

Procedia PDF Downloads 277
5581 Secure Texting Used in a Post-Acute Pediatric Skilled Nursing Inpatient Setting: A Multidisciplinary Care Team Driven Communication System with Alarm and Alert Notification Management

Authors: Bency Ann Massinello, Nancy Day, Janet Fellini

Abstract:

Background: The use of an appropriate mode of communication among the multidisciplinary care team members regarding coordination of care is an extremely complicated yet important patient safety initiative. Effective communication among the team members(nursing staff, medical staff, respiratory therapists, rehabilitation therapists, patient-family services team…) become essential to develop a culture of trust and collaboration to deliver the highest quality care to patients are their families. The inpatient post-acute pediatrics, where children and their caregivers come for continuity of care, is no exceptions to the increasing use of text messages as a means to communication among clinicians. One such platform is the Vocera Communications (Vocera Smart Mobile App called Vocera Edge) allows the teams to use the application and share sensitive patient information through an encrypted platform using IOS company provided shared and assigned mobile devices. Objective: This paper discusses the quality initiative of implementing the transition from Vocera Smartbage to Vocera Edge Mobile App, technology advantage, use case expansion, and lessons learned about a secure alternative modality that allows sending and receiving secure text messages in a pediatric post-acute setting using an IOS device. This implementation process included all direct care staff, ancillary teams, and administrative teams on the clinical units. Methods: Our institution launched this transition from voice prompted hands-free Vocera Smartbage to Vocera Edge mobile based app for secure care team texting using a big bang approach during the first PDSA cycle. The pre and post implementation data was gathered using a qualitative survey of about 500 multidisciplinary team members to determine the ease of use of the application and its efficiency in care coordination. The technology was further expanded in its use by implementing clinical alerts and alarms notification using middleware integration with patient monitoring (Masimo) and life safety (Nurse call) systems. Additional use of the smart mobile iPhone use include pushing out apps like Lexicomp and Up to Date to have it readily available for users for evident-based practice in medication and disease management. Results: Successful implementation of the communication system in a shared and assigned model with all of the multidisciplinary teams in our pediatric post-acute setting. In just a 3-monthperiod post implementation, we noticed a 14% increase from 7,993 messages in 6 days in December 2020 to 9,116messages in March 2021. This confirmed that all clinical and non-clinical teams were using this mode of communication for coordinating the care for their patients. System generated data analytics used in addition to the pre and post implementation staff survey for process evaluation. Conclusion: A secure texting option using a mobile device is a safe and efficient mode for care team communication and collaboration using technology in real time. This allows for the settings like post-acute pediatric care areas to be in line with the widespread use of mobile apps and technology in our mainstream healthcare.

Keywords: nursing informatics, mobile secure texting, multidisciplinary communication, pediatrics post acute care

Procedia PDF Downloads 182