700 Preliminary dosimetric Evaluation of a New Therapeutic 177LU Complex for Human Based on Biodistribution Data in Rats
Authors: H. Yousefnia, S. Zolghadri, A. Golabi Dezfuli
Abstract:
Tris (1,10-phenanthroline) lanthanum(III)] trithiocyanate is a new compound that has shown to stop DNA synthesis in CCRF-CEM and Ehrlich ascites cells leading to a cell cycle arrest in G0/G1. One other important property of the phenanthroline nucleus is its ability to act as a triplet-state photosensitizer especially in complexes with lanthanides. In Nowadays, the radiation dose assessment resource (RADAR) method is known as the most common method for absorbed dose calculation. 177Lu was produced by irradiation of a natural Lu2O3 target at a thermal neutron flux of approximately 4 × 1013 n/cm2•s. 177Lu-PL3 was prepared in the optimized condition. The radiochemical yield was checked by ITLC method. The biodistribution of the complex was investigated by intravenously injection to wild-type rats via their tail veins. In this study, the absorbed dose of 177Lu-PL3 to human organs was estimated by RADAR method. 177Lu was prepared with a specific activity of 2.6-3 GBq.mg-1 and radionuclide purity of 99.98 %. The 177Lu-PL3 complex can prepare with high radiochemical yield (> 99 %) at optimized conditions. The results show that liver and spleen have received the highest absorbed dose of 1.051 and 0.441 mSv/MBq, respectivley. The absorbed dose values for these two dose-limiting tissues suggest more biological studies special in tumor-bearing animals.Keywords: internal dosimetry, Lutetium-177, radar, animals
Procedia PDF Downloads 373699 Human Absorbed Dose Estimation of a New In-111 Imaging Agent Based on Rat Data
Authors: H. Yousefnia, S. Zolghadri
Abstract:
The measurement of organ radiation exposure dose is one of the most important steps to be taken initially, for developing a new radiopharmaceutical. In this study, the dosimetric studies of a novel agent for SPECT-imaging of the bone metastasis, 111In-1,4,7,10-tetraazacyclododecane-1,4,7,10 tetraethylene phosphonic acid (111In-DOTMP) complex, have been carried out to estimate the dose in human organs based on the data derived from rats. The radiolabeled complex was prepared with high radiochemical purity in the optimal conditions. Biodistribution studies of the complex was investigated in the male Syrian rats at selected times after injection (2, 4, 24 and 48 h). The human absorbed dose estimation of the complex was made based on data derived from the rats by the radiation absorbed dose assessment resource (RADAR) method. 111In-DOTMP complex was prepared with high radiochemical purity of >99% (ITLC). Total body effective absorbed dose for 111In-DOTMP was 0.061 mSv/MBq. This value is comparable to the other 111In clinically used complexes. The results show that the dose with respect to the critical organs is satisfactory within the acceptable range for diagnostic nuclear medicine procedures. Generally, 111In-DOTMP has interesting characteristics and can be considered as a viable agent for SPECT-imaging of the bone metastasis in the near future.Keywords: In-111, DOTMP, Internal Dosimetry, RADAR
Procedia PDF Downloads 407698 Assessment of E-Learning Facilities in Open and Distance Learning and Information Need by Students
Authors: Sabo Elizabeth
Abstract:
Electronic learning is increasingly popular learning approach in higher educational institutions due to vast growth of internet technology. This approach is important in human capital development. An investigation of open distance and e-learning facilities and information need by open and distance learning students was carried out in Jalingo, Nigeria. Structured questionnaires were administered to 70 registered ODL students of the NOUN. Information sourced from the respondents covered demographic, economic and institutional variables. Data collected for demographic variables were computed as frequency count and percentages. Assessment of the effectiveness of ODL facilities and information need among open and distance learning students was computed on a three or four point Likert Rating Scale. Findings indicated that there are more men compared to women. A large proportion of the respondents are married and there are more matured students in ODL compared to the youth. A high proportion of the ODL students obtained qualifications higher than the secondary school certificate. The proportion of computer literate ODL students was high, and large number of the students does not own a laptop computer. Inadequate e -books and reference materials, internet gadgets and inadequate books (hard copies) and reference material are factors that limit utilization of e-learning facilities in the study areas. Inadequate computer facilities and power back up caused inconveniences and delay in administering and use of e learning facilities. To a high extent, open and distance learning students needed information on university time table and schedule of activities, availability and access to books (hard and e-books) and reference materials. The respondents emphasized that contact with course coordinators via internet will provide a better learning and academic performance.Keywords: open and distance learning, information required, electronic books, internet gadgets, Likert scale test
Procedia PDF Downloads 325697 Performance Evaluation of a Very High-Resolution Satellite Telescope
Authors: Walid A. Attia, Taher M. Bazan, Fawzy Eltohamy, Mahmoud Fathy
Abstract:
System performance evaluation is an essential stage in the design of high-resolution satellite telescopes prior to the development process. In this paper, a system performance evaluation of a very high-resolution satellite telescope is investigated. The evaluated system has a Korsch optical scheme design. This design has been discussed in another paper with respect to three-mirror anastigmat (TMA) scheme design and the former configuration showed better results. The investigated system is based on the Korsch optical design integrated with a time-delay and integration charge coupled device (TDI-CCD) sensor to achieve a ground sampling distance (GSD) of 25 cm. The key performance metrics considered are the spatial resolution, the signal to noise ratio (SNR) and the total modulation transfer function (MTF) of the system. In addition, the national image interpretability rating scale (NIIRS) metric is assessed to predict the image quality according to the modified general image quality equation (GIQE). Based on the orbital, optical and detector parameters, the estimated GSD is found to be 25 cm. The SNR has been analyzed at different illumination conditions of target albedos, sun and sensor angles. The system MTF has been computed including diffraction, aberration, optical manufacturing, smear and detector sampling as the main contributors for evaluation the MTF. Finally, the system performance evaluation results show that the computed MTF value is found to be around 0.08 at the Nyquist frequency, the SNR value was found to be 130 at albedo 0.2 with a nadir viewing angles and the predicted NIIRS is in the order of 6.5 which implies a very good system image quality.Keywords: modulation transfer function, national image interpretability rating scale, signal to noise ratio, satellite telescope performance evaluation
Procedia PDF Downloads 384696 The Effect of Gamma rays on Physicochemical Properties of Carboxymethyl Starch
Authors: N. Rajeswara Rao, T. Venkatappa Rao, K. Sowri Babu, N. Srinivas Rao, P. S. V. Shanmukhi
Abstract:
Carboxymethyl Starch (CMS) is a biopolymer derived from starch by the substitution method. CMS is proclaimed to have improved physicochemical properties than native starch. The present work deals with the effect of gamma radiation on the physicochemical properties of CMS. The samples were exposed to gamma irradiation of doses 30, 60 and 90 kGy. The resultant properties were studied with electron spin resonance (ESR), fourier transform infrared spectrometer (FTIR), differential scanning calorimeter (DSC), X-ray diffractometer (XRD) and scanning electron microscopy. Irradiation of CMS by gamma rays initiates cleavage of glucosidic bonds producing different types of radicals. Some of these radicals convert to peroxy radicals by abstracting oxygen. The ESR spectrum of CMS is anisotropic and is thought to be due to the superposition of various component spectra. In order to analyze the ESR spectrum, computer simulations were also employed. ESR spectra are also recorded under different conditions like post-irradiation times, variable temperatures and saturation behavior in order to evaluate the stability of free radicals produced on irradiation. Thermal studies from DSC depict that for CMS the gelatization process was absconded at higher doses. Relative crystallinity was reduced significantly after irradiation from XRD Studies. FTIR studies also confirm the same aspect. From ESR studies, it was concluded that irradiated CMS could be a potential reference material in ESR dosimetry.Keywords: gamma rays, free radicals, ESR simulations, gelatization
Procedia PDF Downloads 104695 Optimization and Evaluation of 177lu-Dotatoc as a Potential Agent for Peptide Receptor Radionuclide Therapy
Authors: H. Yousefnia, MS. Mousavi-Daramoroudi, S. Zolghadri, F. Abbasi-Davani
Abstract:
High expression of somatostatin receptors on a wide range of human tumours makes them as potential targets for peptide receptor radionuclide tomography. A series of octreotide analogues were synthesized while [DOTA-DPhe1, Tyr3]octreotide (DOTATOC) indicated advantageous properties in tumour models. In this study, 177Lu-DOTATOC was prepared with the radiochemical purity of higher than 99% in 30 min at the optimized condition. Biological behavior of the complex was studied after intravenous injection into the Syrian rats. Major difference uptake was observed compared to 177LuCl3 solution especially in somatostatin receptor-positive tissues such as pancreas and adrenal.Keywords: Biodistribution, 177Lu, Octreotide, Syrian rats
Procedia PDF Downloads 449694 Separating Landform from Noise in High-Resolution Digital Elevation Models through Scale-Adaptive Window-Based Regression
Authors: Anne M. Denton, Rahul Gomes, David W. Franzen
Abstract:
High-resolution elevation data are becoming increasingly available, but typical approaches for computing topographic features, like slope and curvature, still assume small sliding windows, for example, of size 3x3. That means that the digital elevation model (DEM) has to be resampled to the scale of the landform features that are of interest. Any higher resolution is lost in this resampling. When the topographic features are computed through regression that is performed at the resolution of the original data, the accuracy can be much higher, and the reported result can be adjusted to the length scale that is relevant locally. Slope and variance are calculated for overlapping windows, meaning that one regression result is computed per raster point. The number of window centers per area is the same for the output as for the original DEM. Slope and variance are computed by performing regression on the points in the surrounding window. Such an approach is computationally feasible because of the additive nature of regression parameters and variance. Any doubling of window size in each direction only takes a single pass over the data, corresponding to a logarithmic scaling of the resulting algorithm as a function of the window size. Slope and variance are stored for each aggregation step, allowing the reported slope to be selected to minimize variance. The approach thereby adjusts the effective window size to the landform features that are characteristic to the area within the DEM. Starting with a window size of 2x2, each iteration aggregates 2x2 non-overlapping windows from the previous iteration. Regression results are stored for each iteration, and the slope at minimal variance is reported in the final result. As such, the reported slope is adjusted to the length scale that is characteristic of the landform locally. The length scale itself and the variance at that length scale are also visualized to aid in interpreting the results for slope. The relevant length scale is taken to be half of the window size of the window over which the minimum variance was achieved. The resulting process was evaluated for 1-meter DEM data and for artificial data that was constructed to have defined length scales and added noise. A comparison with ESRI ArcMap was performed and showed the potential of the proposed algorithm. The resolution of the resulting output is much higher and the slope and aspect much less affected by noise. Additionally, the algorithm adjusts to the scale of interest within the region of the image. These benefits are gained without additional computational cost in comparison with resampling the DEM and computing the slope over 3x3 images in ESRI ArcMap for each resolution. In summary, the proposed approach extracts slope and aspect of DEMs at the lengths scales that are characteristic locally. The result is of higher resolution and less affected by noise than existing techniques.Keywords: high resolution digital elevation models, multi-scale analysis, slope calculation, window-based regression
Procedia PDF Downloads 129693 Discrete Element Simulations of Composite Ceramic Powders
Authors: Julia Cristina Bonaldo, Christophe L. Martin, Severine Romero Baivier, Stephane Mazerat
Abstract:
Alumina refractories are commonly used in steel and foundry industries. These refractories are prepared through a powder metallurgy route. They are a mixture of hard alumina particles and graphite platelets embedded into a soft carbonic matrix (binder). The powder can be cold pressed isostatically or uniaxially, depending on the application. The compact is then fired to obtain the final product. The quality of the product is governed by the microstructure of the composite and by the process parameters. The compaction behavior and the mechanical properties of the fired product depend greatly on the amount of each phase, on their morphology and on the initial microstructure. In order to better understand the link between these parameters and the macroscopic behavior, we use the Discrete Element Method (DEM) to simulate the compaction process and the fracture behavior of the fired composite. These simulations are coupled with well-designed experiments. Four mixes with various amounts of Al₂O₃ and binder were tested both experimentally and numerically. In DEM, each particle is modelled and the interactions between particles are taken into account through appropriate contact or bonding laws. Here, we model a bimodal mixture of large Al₂O₃ and small Al₂O₃ covered with a soft binder. This composite is itself mixed with graphite platelets. X-ray tomography images are used to analyze the morphologies of the different components. Large Al₂O₃ particles and graphite platelets are modelled in DEM as sets of particles bonded together. The binder is modelled as a soft shell that covers both large and small Al₂O₃ particles. When two particles with binder indent each other, they first interact through this soft shell. Once a critical indentation is reached (towards the end of compaction), hard Al₂O₃ - Al₂O₃ contacts appear. In accordance with experimental data, DEM simulations show that the amount of Al₂O₃ and the amount of binder play a major role for the compaction behavior. The graphite platelets bend and break during the compaction, also contributing to the macroscopic stress. Firing step is modeled in DEM by ascribing bonds to particles which contact each other after compaction. The fracture behavior of the compacted mixture is also simulated and compared with experimental data. Both diametrical tests (Brazilian tests) and triaxial tests are carried out. Again, the link between the amount of Al₂O₃ particles and the fracture behavior is investigated. The methodology described here can be generalized to other particulate materials that are used in the ceramic industry.Keywords: cold compaction, composites, discrete element method, refractory materials, x-ray tomography
Procedia PDF Downloads 139692 Gas Flow, Time, Distance Dynamic Modelling
Authors: A. Abdul-Ameer
Abstract:
The equations governing the distance, pressure- volume flow relationships for the pipeline transportation of gaseous mixtures, are considered. A derivation based on differential calculus, for an element of this system model, is addressed. Solutions, yielding the input- output response following pressure changes, are reviewed. The technical problems associated with these analytical results are identified. Procedures resolving these difficulties providing thereby an attractive, simple, analysis route are outlined. Computed responses, validating thereby calculated predictions, are presented.Keywords: pressure, distance, flow, dissipation, models
Procedia PDF Downloads 475691 Lifespan Assessment of the Fish Crossing System of Itaipu Power Plant (Brazil/Paraguay) Based on the Reaching of Its Sedimentological Equilibrium Computed by 3D Modeling and Churchill Trapping Efficiency
Authors: Anderson Braga Mendes, Wallington Felipe de Almeida, Cicero Medeiros da Silva
Abstract:
This study aimed to assess the lifespan of the fish transposition system of the Itaipu Power Plant (Brazil/Paraguay) by using 3D hydrodynamic modeling and Churchill trapping effiency in order to identify the sedimentological equilibrium configuration in the main pond of the Piracema Channel, which is part of a 10 km hydraulic circuit that enables fish migration from downstream to upstream (and vice-versa) the Itaipu Dam, overcoming a 120 m water drop. For that, bottom data from 2002 (its opening year) and 2015 were collected and analyzed, besides bed material at 12 stations to the purpose of identifying their granulometric profiles. The Shields and Yalin and Karahan diagrams for initiation of motion of bed material were used to determine the critical bed shear stress for the sedimentological equilibrium state based on the sort of sediment (grain size) to be found at the bottom once the balance is reached. Such granulometry was inferred by analyzing the grosser material (fine and medium sands) which inflows the pond and deposits in its backwater zone, being adopted a range of diameters within the upper and lower limits of that sand stratification. The software Delft 3D was used in an attempt to compute the bed shear stress at every station under analysis. By modifying the input bathymetry of the main pond of the Piracema Channel so as to the computed bed shear stress at each station fell within the intervals of acceptable critical stresses simultaneously, it was possible to foresee the bed configuration of the main pond when the sedimentological equilibrium is reached. Under such condition, 97% of the whole pond capacity will be silted, and a shallow water course with depths ranging from 0.2 m to 1.5 m will be formed; in 2002, depths ranged from 2 m to 10 m. Out of that water path, the new bottom will be practically flat and covered by a layer of water 0.05 m thick. Thus, in the future the main pond of the Piracema Channel will lack its purpose of providing a resting place for migrating fish species, added to the fact that it may become an insurmountable barrier for medium and large sized specimens. Everything considered, it was estimated that its lifespan, from the year of its opening to the moment of the sedimentological equilibrium configuration, will be approximately 95 years–almost half of the computed lifespan of Itaipu Power Plant itself. However, it is worth mentioning that drawbacks concerning the silting in the main pond will start being noticed much earlier than such time interval owing to the reasons previously mentioned.Keywords: 3D hydrodynamic modeling, Churchill trapping efficiency, fish crossing system, Itaipu power plant, lifespan, sedimentological equilibrium
Procedia PDF Downloads 234690 Atypical Intoxication Due to Fluoxetine Abuse with Symptoms of Amnesia
Authors: Ayse Gul Bilen
Abstract:
Selective serotonin reuptake inhibitors (SSRIs) are commonly prescribed antidepressants that are used clinically for the treatment of anxiety disorders, obsessive-compulsive disorder (OCD), panic disorders and eating disorders. The first SSRI, fluoxetine (sold under the brand names Prozac and Sarafem among others), had an adverse effect profile better than any other available antidepressant when it was introduced because of its selectivity for serotonin receptors. They have been considered almost free of side effects and have become widely prescribed, however questions about the safety and tolerability of SSRIs have emerged with their continued use. Most SSRI side effects are dose-related and can be attributed to serotonergic effects such as nausea. Continuous use might trigger adverse effects such as hyponatremia, tremor, nausea, weight gain, sleep disturbance and sexual dysfunction. Moderate toxicity can be safely observed in the hospital for 24 hours, and mild cases can be safely discharged (if asymptomatic) from the emergency department once cleared by Psychiatry in cases of intentional overdose and after 6 to 8 hours of observation. Although fluoxetine is relatively safe in terms of overdose, it might still be cardiotoxic and inhibit platelet secretion, aggregation, and plug formation. There have been reported clinical cases of seizures, cardiac conduction abnormalities, and even fatalities associated with fluoxetine ingestions. While the medical literature strongly suggests that most fluoxetine overdoses are benign, emergency physicians need to remain cognizant that intentional, high-dose fluoxetine ingestions may induce seizures and can even be fatal due to cardiac arrhythmia. Our case is a 35-year old female patient who was sent to ER with symptoms of confusion, amnesia and loss of orientation for time and location after being found wandering in the streets unconsciously by police forces that informed 112. Upon laboratory examination, no pathological symptom was found except sinus tachycardia in the EKG and high levels of aspartate transaminase (AST) and alanine transaminase (ALT). Diffusion MRI and computed tomography (CT) of the brain all looked normal. Upon physical and sexual examination, no signs of abuse or trauma were found. Test results for narcotics, stimulants and alcohol were negative as well. There was a presence of dysrhythmia which required admission to the intensive care unit (ICU). The patient gained back her conscience after 24 hours. It was discovered from her story afterward that she had been using fluoxetine due to post-traumatic stress disorder (PTSD) for 6 months and that she had attempted suicide after taking 3 boxes of fluoxetine due to the loss of a parent. She was then transferred to the psychiatric clinic. Our study aims to highlight the need to consider toxicologic drug use, in particular, the abuse of selective serotonin reuptake inhibitors (SSRIs), which have been widely prescribed due to presumed safety and tolerability, for diagnosis of patients applying to the emergency room (ER).Keywords: abuse, amnesia, fluoxetine, intoxication, SSRI
Procedia PDF Downloads 201689 Investigation of Input Energy Efficiency in Corn (KSC704) Farming in Khoy City, Iran
Authors: Nasser Hosseini
Abstract:
Energy cycle is one of the essential points in agricultural ecosystems all over the world. Corn is one of the important products in Khoy city. Knowing input energy level and evaluating output energy from farms to reduce energy and increase efficiency in farms is very important if one can reduce input energy level into farms through the indices like poisons, fertilization, tractor energy and labour force. In addition to the net income of the farmers, this issue would play a significant role in preserving farm ecosystem from pollution and wrecker factors. For this reason, energy balance sheet in corn farms as well as input and output energy in 2012-2013 were researched by distributing a questionnaire among farmers in various villages in Khoy city. Then, the input energy amount into farms via energy-consuming factors, mentioned above, with regard to special coefficients was computed. Energy was computed on the basis of seed corn function, chemical compound and its content as well. In this investigation, we evaluated the level of stored energy 10792831 kcal per hectare. We found out that the greatest part of energy depended on irrigation which has 5136141.8 kcal and nitrate fertilizer energy with 2509760 kcal and the lowest part of energy depended on phosphor fertilizer, the rate of posited energy equaled 36362500 kcal and energy efficiency on the basis of seed corn function were estimated as 3.36. We found some ways to reduce consumptive energy in farm and nitrate fertilizer and, on the other hand, to increase balance sheet. They are, to name a few, using alternative farming and potherbs for biological stabilizing of nitrogen and changing kind of fertilizers such as urea fertilizer with sulphur cover, and using new generation of irrigation, the compound of water super absorbent like colored hydrogels and using natural fertilizer to preserve.Keywords: corn (KSC704), output and input, energy efficiency, Khoy city
Procedia PDF Downloads 441688 Automation of Savitsky's Method for Power Calculation of High Speed Vessel and Generating Empirical Formula
Authors: M. Towhidur Rahman, Nasim Zaman Piyas, M. Sadiqul Baree, Shahnewaz Ahmed
Abstract:
The design of high-speed craft has recently become one of the most active areas of naval architecture. Speed increase makes these vehicles more efficient and useful for military, economic or leisure purpose. The planing hull is designed specifically to achieve relatively high speed on the surface of the water. Speed on the water surface is closely related to the size of the vessel and the installed power. The Savitsky method was first presented in 1964 for application to non-monohedric hulls and for application to stepped hulls. This method is well known as a reliable comparative to CFD analysis of hull resistance. A computer program based on Savitsky’s method has been developed using MATLAB. The power of high-speed vessels has been computed in this research. At first, the program reads some principal parameters such as displacement, LCG, Speed, Deadrise angle, inclination of thrust line with respect to keel line etc. and calculates the resistance of the hull using empirical planning equations of Savitsky. However, some functions used in the empirical equations are available only in the graphical form, which is not suitable for the automatic computation. We use digital plotting system to extract data from nomogram. As a result, value of wetted length-beam ratio and trim angle can be determined directly from the input of initial variables, which makes the power calculation automated without manually plotting of secondary variables such as p/b and other coefficients and the regression equations of those functions are derived by using data from different charts. Finally, the trim angle, mean wetted length-beam ratio, frictional coefficient, resistance, and power are computed and compared with the results of Savitsky and good agreement has been observed.Keywords: nomogram, planing hull, principal parameters, regression
Procedia PDF Downloads 405687 Bruch’s Membrane Opening in High Myopia and Its Correlation with Axial Length
Authors: Sanjeeb Kumar Mishra, Aartee Jha, Madhu Thapa, Pragati Gautam
Abstract:
Introduction: High myopia has become a matter of global concern as it is a major risk factor for glaucoma. Various optic nerve head changes occur in high myopia over time. This might lead to difficulty in detecting pathologies associated with high myopia through conventional funduscopy examinations only. Bruch’s Membrane Opening (Area and Minimum Rim Width) is considered an anatomically more accurate and reliable landmark than the conventional clinical disc margin. Study Design: It was a hospital based cross-sectional and non-interventional type of study. Purpose: The purpose of our study was to measure Bruch’s Membrane Opening (area and Minimum Rim Width) in high myopic eyes and correlate it with axial length. Methods: A cross-sectional study was conducted at B.P Koirala Lions Center for Ophthalmic Studies, a tertiary-level eye center in Nepal. 80 eyes of 40 subjects (40% male and 60% female) aged 18-35 years with high myopia (Spherical Equivalent (SE) ≥ -6D) were taken as cases. Among them, RE of 39 and LE of 34 myopic subjects were included in the study. Spectral Domain-Optical Coherence Tomography of both the eyes of myopic patients was performed using Glaucoma Module Premiere Edition (GMPE) with Anatomic Positioning System (APS) to measure Bruch’s Membrane Opening (Area and Minimum Rim Width). Axial length in myopic patients was measured using Partial Coherence Interferometry (IOL Master). Results: Among 40 myopic subjects, 16 (40%) were males, whereas 24 (60%) were females. The mean age of myopic subjects was 24.64 ± 5.10 years, with minimum and maximum ages of 18 years and 35 years, respectively. The mean BMO area was 2.28 0.48 mm² in right eye and 2.15 0.59 mm² in left eye. BMO area in high myopic patient was significantly correlated with axial length. The correlation analysis of BMO area with axial length in RE and LE was found to be statistically significant at (r=0.465, p<0.003) and (r=0.374, p< 0.029), respectively. Likewise, the mean BMO-MRW was 325.69 ± 96µm in right eye and 339.20 ± 79.50µm in left eye. There was a significant correlation of BMO-MRW with axial length in both the eyes of myopic subjects. Moreover, a significant negative correlation of Inferior temporal, Nasal, and Inferior nasal quadrants (p<0.05) of BMO-MRW of right eye was found with axial length of right eye, whereas all the BMO-MRW quadrants of left eye were negatively correlated (p<0.05) with axial length in left eye. No significant differences were found between right eye and left eye on comparing means of refractive error, axial length, BMO area, and BMO-MRW. Conclusion: From this study, it can be concluded that BMO area enlarges in high myopia with an increase in axial length. Additionally, BMO-MRW thinning occurs along with the BMO enlargement and increases with axial length. There were no significant differences in refractive error, axial length, BMO area, and BMO-MRW between right eye and left eye.Keywords: high myopia, Bruch’s membrane opening, Bruch’s membrane opening minimum rim width, spectral domain optical coherence tomography
Procedia PDF Downloads 22686 Subdural Hematoma: A Rare Complication of ITP
Authors: Muhammad Faisal Khilji, Rana Shoaib Hamid
Abstract:
Subdural hematoma (SDH) is an extremely rare complication of immune thrombocytopenic purpura (ITP). We present a case of a 34 years old female who presented to the Emergency department of a tertiary care hospital with complaints of headache, on and off gums bleeding and upper respiratory tract symptoms for the last two weeks. Examination was unremarkable except some purpura over limbs. Investigations revealed zero platelets and peripheral film suggestive of ITP. Computerized tomography (CT) brain revealed bilateral SDH in the frontal areas extending into Falx cerebri. Impression of ITP with SDH was made. Patient was treated with intravenous immunoglobulin (IVIg), methyl prednisolone and initial Platelets transfusion. Patient recovered uneventfully with platelets reaching normal levels within a few days and resolution of SDH without surgery.Keywords: headache, immune thrombocytopenia, purpura, subdural hematoma
Procedia PDF Downloads 398685 Multimodal Integration of EEG, fMRI and Positron Emission Tomography Data Using Principal Component Analysis for Prognosis in Coma Patients
Authors: Denis Jordan, Daniel Golkowski, Mathias Lukas, Katharina Merz, Caroline Mlynarcik, Max Maurer, Valentin Riedl, Stefan Foerster, Eberhard F. Kochs, Andreas Bender, Ruediger Ilg
Abstract:
Introduction: So far, clinical assessments that rely on behavioral responses to differentiate coma states or even predict outcome in coma patients are unreliable, e.g. because of some patients’ motor disabilities. The present study was aimed to provide prognosis in coma patients using markers from electroencephalogram (EEG), blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) and [18F]-fluorodeoxyglucose (FDG) positron emission tomography (PET). Unsuperwised principal component analysis (PCA) was used for multimodal integration of markers. Methods: Approved by the local ethics committee of the Technical University of Munich (Germany) 20 patients (aged 18-89) with severe brain damage were acquired through intensive care units at the Klinikum rechts der Isar in Munich and at the Therapiezentrum Burgau (Germany). At the day of EEG/fMRI/PET measurement (date I) patients (<3.5 month in coma) were grouped in the minimal conscious state (MCS) or vegetative state (VS) on the basis of their clinical presentation (coma recovery scale-revised, CRS-R). Follow-up assessment (date II) was also based on CRS-R in a period of 8 to 24 month after date I. At date I, 63 channel EEG (Brain Products, Gilching, Germany) was recorded outside the scanner, and subsequently simultaneous FDG-PET/fMRI was acquired on an integrated Siemens Biograph mMR 3T scanner (Siemens Healthineers, Erlangen Germany). Power spectral densities, permutation entropy (PE) and symbolic transfer entropy (STE) were calculated in/between frontal, temporal, parietal and occipital EEG channels. PE and STE are based on symbolic time series analysis and were already introduced as robust markers separating wakefulness from unconsciousness in EEG during general anesthesia. While PE quantifies the regularity structure of the neighboring order of signal values (a surrogate of cortical information processing), STE reflects information transfer between two signals (a surrogate of directed connectivity in cortical networks). fMRI was carried out using SPM12 (Wellcome Trust Center for Neuroimaging, University of London, UK). Functional images were realigned, segmented, normalized and smoothed. PET was acquired for 45 minutes in list-mode. For absolute quantification of brain’s glucose consumption rate in FDG-PET, kinetic modelling was performed with Patlak’s plot method. BOLD signal intensity in fMRI and glucose uptake in PET was calculated in 8 distinct cortical areas. PCA was performed over all markers from EEG/fMRI/PET. Prognosis (persistent VS and deceased patients vs. recovery to MCS/awake from date I to date II) was evaluated using the area under the curve (AUC) including bootstrap confidence intervals (CI, *: p<0.05). Results: Prognosis was reliably indicated by the first component of PCA (AUC=0.99*, CI=0.92-1.00) showing a higher AUC when compared to the best single markers (EEG: AUC<0.96*, fMRI: AUC<0.86*, PET: AUC<0.60). CRS-R did not show prediction (AUC=0.51, CI=0.29-0.78). Conclusion: In a multimodal analysis of EEG/fMRI/PET in coma patients, PCA lead to a reliable prognosis. The impact of this result is evident, as clinical estimates of prognosis are inapt at time and could be supported by quantitative biomarkers from EEG, fMRI and PET. Due to the small sample size, further investigations are required, in particular allowing superwised learning instead of the basic approach of unsuperwised PCA.Keywords: coma states and prognosis, electroencephalogram, entropy, functional magnetic resonance imaging, machine learning, positron emission tomography, principal component analysis
Procedia PDF Downloads 340684 Investigation of Bremsstrahlung, Braking Radiation from Beta-Emitting Radioactive Sources
Authors: Metin Kömsöken, Ayşe Güneş Tanır, Onur Karaman
Abstract:
Usage of high energy charged particles for diagnosis and treatment has been widespread in medicine. The main purpose is to investigate that Bremsstrahlung which occurs by tissue interactions with charged particles should not be neglected. Nuclear stopping power (Bremsstrahlung) was calculated for lung, brain, skin, muscle, bone (cortical) and water targets for the energies of electrons obtained from LINAC used in radiotherapy and of β+ sources used in positron emission tomography (PET). These calculations were done by using the four different analytical functions including classical Bethe-Bloch, Tsoulfanidis, modified Bethe-Bloch and modified Tsoulfanidis equations. It was concluded that obtained results were compatible with that of National Institute of Standards and Technology (NIST-ESTAR).Keywords: β- emitting source, bremsstrahlung, therapeutic radionuclides, LINAC
Procedia PDF Downloads 335683 Fusion Neutron Generator Dosimetry and Applications for Medical, Security, and Industry
Authors: Kaouther Bergaui, Nafaa Reguigui, Charles Gary
Abstract:
Characterization and the applications of deuterium-deuterium (DD) neutron generator developed by Adelphie technology and acquired by the National Centre of Nuclear Science and Technology (NCNST) were presented in this work. We study the performance of the neutron generator in terms of neutron yield, production efficiency, and the ionic current as a function of the acceleration voltage at various RF powers. We provide the design and optimization of the PGNAA chamber and thus give insight into the capabilities of the planned PGNAA facility. Additional non-destructive techniques were studied employing the DD neutron generator, such as PGNAA and neutron radiography: The PGNAA is used for determining the concentration of 10B in Si and SiO2 matrices by using a germanium detector HPGe and the results obtained are compared with PGNAA system using a Sodium Iodide detector (NaI (Tl)); Neutron radiography facility was tested and simulated, using a camera device CCD and simulated by the Monte Carlo code; and the explosive detection system (EDS) also simulated using the Monte Carlo code. The study allows us to show that the new models of DD neutron generators are feasible and that superior-quality neutron beams could be produced and used for various applications. The feasibility of Boron neutron capture therapy (BNCT) for cancer treatment using a neutron generator was assessed by optimizing Beam Shaping Assembly (BSA) on a phantom using Monte-Carlo (MCNP6) simulations.Keywords: neutron generator deuterium-deuterium, Monte Carlo method, radiation, neutron flux, neutron activation analysis, born, neutron radiography, explosive detection, BNCT
Procedia PDF Downloads 197682 Optimization of Perfusion Distribution in Custom Vascular Stent-Grafts Through Patient-Specific CFD Models
Authors: Scott M. Black, Craig Maclean, Pauline Hall Barrientos, Konstantinos Ritos, Asimina Kazakidi
Abstract:
Aortic aneurysms and dissections are leading causes of death in cardiovascular disease. Both inevitably lead to hemodynamic instability without surgical intervention in the form of vascular stent-graft deployment. An accurate description of the aortic geometry and blood flow in patient-specific cases is vital for treatment planning and long-term success of such grafts, as they must generate physiological branch perfusion and in-stent hemodynamics. The aim of this study was to create patient-specific computational fluid dynamics (CFD) models through a multi-modality, multi-dimensional approach with boundary condition optimization to predict branch flow rates and in-stent hemodynamics in custom stent-graft configurations. Three-dimensional (3D) thoracoabdominal aortae were reconstructed from four-dimensional flow-magnetic resonance imaging (4D Flow-MRI) and computed tomography (CT) medical images. The former employed a novel approach to generate and enhance vessel lumen contrast via through-plane velocity at discrete, user defined cardiac time steps post-hoc. To produce patient-specific boundary conditions (BCs), the aortic geometry was reduced to a one-dimensional (1D) model. Thereafter, a zero-dimensional (0D) 3-Element Windkessel model (3EWM) was coupled to each terminal branch to represent the distal vasculature. In this coupled 0D-1D model, the 3EWM parameters were optimized to yield branch flow waveforms which are representative of the 4D Flow-MRI-derived in-vivo data. Thereafter, a 0D-3D CFD model was created, utilizing the optimized 3EWM BCs and a 4D Flow-MRI-obtained inlet velocity profile. A sensitivity analysis on the effects of stent-graft configuration and BC parameters was then undertaken using multiple stent-graft configurations and a range of distal vasculature conditions. 4D Flow-MRI granted unparalleled visualization of blood flow throughout the cardiac cycle in both the pre- and postsurgical states. Segmentation and reconstruction of healthy and stented regions from retrospective 4D Flow-MRI images also generated 3D models with geometries which were successfully validated against their CT-derived counterparts. 0D-1D coupling efficiently captured branch flow and pressure waveforms, while 0D-3D models also enabled 3D flow visualization and quantification of clinically relevant hemodynamic parameters for in-stent thrombosis and graft limb occlusion. It was apparent that changes in 3EWM BC parameters had a pronounced effect on perfusion distribution and near-wall hemodynamics. Results show that the 3EWM parameters could be iteratively changed to simulate a range of graft limb diameters and distal vasculature conditions for a given stent-graft to determine the optimal configuration prior to surgery. To conclude, this study outlined a methodology to aid in the prediction post-surgical branch perfusion and in-stent hemodynamics in patient specific cases for the implementation of custom stent-grafts.Keywords: 4D flow-MRI, computational fluid dynamics, vascular stent-grafts, windkessel
Procedia PDF Downloads 181681 A Pull-Out Fiber/Matrix Interface Characterization of Vegetal Fibers Reinforced Thermoplastic Polymer Composites, the Influence of the Processing Temperature
Authors: Duy Cuong Nguyen, Ali Makke, Guillaume Montay
Abstract:
This work presents an improved single fiber pull-out test for fiber/matrix interface characterization. This test has been used to study the Inter-Facial Shear Strength ‘IFSS’ of hemp fibers reinforced polypropylene (PP). For this aim, the fiber diameter has been carefully measured using a tomography inspired method. The fiber section contour can then be approximated by a circle or a polygon. The results show that the IFSS is overestimated if the circular approximation is used. The Influence of the molding temperature on the IFSS has also been studied. We find a molding temperature of 183°C leads to better interface properties. Above or below this temperature the interface strength is reduced.Keywords: composite, hemp, interface, pull-out, processing, polypropylene, temperature
Procedia PDF Downloads 392680 Deep Learning-Based Classification of 3D CT Scans with Real Clinical Data; Impact of Image format
Authors: Maryam Fallahpoor, Biswajeet Pradhan
Abstract:
Background: Artificial intelligence (AI) serves as a valuable tool in mitigating the scarcity of human resources required for the evaluation and categorization of vast quantities of medical imaging data. When AI operates with optimal precision, it minimizes the demand for human interpretations and, thereby, reduces the burden on radiologists. Among various AI approaches, deep learning (DL) stands out as it obviates the need for feature extraction, a process that can impede classification, especially with intricate datasets. The advent of DL models has ushered in a new era in medical imaging, particularly in the context of COVID-19 detection. Traditional 2D imaging techniques exhibit limitations when applied to volumetric data, such as Computed Tomography (CT) scans. Medical images predominantly exist in one of two formats: neuroimaging informatics technology initiative (NIfTI) and digital imaging and communications in medicine (DICOM). Purpose: This study aims to employ DL for the classification of COVID-19-infected pulmonary patients and normal cases based on 3D CT scans while investigating the impact of image format. Material and Methods: The dataset used for model training and testing consisted of 1245 patients from IranMehr Hospital. All scans shared a matrix size of 512 × 512, although they exhibited varying slice numbers. Consequently, after loading the DICOM CT scans, image resampling and interpolation were performed to standardize the slice count. All images underwent cropping and resampling, resulting in uniform dimensions of 128 × 128 × 60. Resolution uniformity was achieved through resampling to 1 mm × 1 mm × 1 mm, and image intensities were confined to the range of (−1000, 400) Hounsfield units (HU). For classification purposes, positive pulmonary COVID-19 involvement was designated as 1, while normal images were assigned a value of 0. Subsequently, a U-net-based lung segmentation module was applied to obtain 3D segmented lung regions. The pre-processing stage included normalization, zero-centering, and shuffling. Four distinct 3D CNN models (ResNet152, ResNet50, DensNet169, and DensNet201) were employed in this study. Results: The findings revealed that the segmentation technique yielded superior results for DICOM images, which could be attributed to the potential loss of information during the conversion of original DICOM images to NIFTI format. Notably, ResNet152 and ResNet50 exhibited the highest accuracy at 90.0%, and the same models achieved the best F1 score at 87%. ResNet152 also secured the highest Area under the Curve (AUC) at 0.932. Regarding sensitivity and specificity, DensNet201 achieved the highest values at 93% and 96%, respectively. Conclusion: This study underscores the capacity of deep learning to classify COVID-19 pulmonary involvement using real 3D hospital data. The results underscore the significance of employing DICOM format 3D CT images alongside appropriate pre-processing techniques when training DL models for COVID-19 detection. This approach enhances the accuracy and reliability of diagnostic systems for COVID-19 detection.Keywords: deep learning, COVID-19 detection, NIFTI format, DICOM format
Procedia PDF Downloads 89679 Effect of Printing Process on Mechanical Properties and Porosity of 3D Printed Concrete Strips
Authors: Wei Chen
Abstract:
3D concrete printing technology is a novel and highly efficient construction method that holds significant promise for advancing low-carbon initiatives within the construction industry. In contrast to traditional construction practices, 3D printing offers a manual and formwork-free approach, resulting in a transformative shift in labor requirements and fabrication techniques. This transition yields substantial reductions in carbon emissions during the construction phase, as well as decreased on-site waste generation. Furthermore, when compared to conventionally printed concrete, 3D concrete exhibits mechanical anisotropy due to its layer-by-layer construction methodology. Therefore, it becomes imperative to investigate the influence of the printing process on the mechanical properties of 3D printed strips and to optimize the mechanical characteristics of these coagulated strips. In this study, we conducted three-dimensional reconstructions of printed blocks using both circular and directional print heads, incorporating various overlap distances between strips, and employed CT scanning for comprehensive analysis. Our research focused on assessing mechanical properties and micro-pore characteristics under different loading orientations.Our findings reveal that increasing the overlap degree between strips leads to enhanced mechanical properties of the strips. However, it's noteworthy that once full overlap is achieved, further increases in the degree of coincidence do not lead to a decrease in porosity between strips. Additionally, due to its superior printing cross-sectional area, the square printing head exhibited the most favorable impact on mechanical properties.This paper aims to improve the tensile strength, tensile ductility, and bending toughness of a recently developed ‘one-part’ geopolymer for 3D concrete printing (3DCP) applications, in order to address the insufficient tensile strength and brittle fracture characteristics of geopolymer materials in 3D printing scenarios where materials are subjected to tensile stress. The effects of steel fiber content, and aspect ratio, on mechanical properties, were systematically discussed, including compressive strength, flexure strength, splitting tensile strength, uniaxial tensile strength, bending toughness, and the anisotropy of 3DP-OPGFRC, respectively. The fiber distribution in the printed samples was obtained through x-ray computed tomography (X-CT) testing. In addition, the underlying mechanisms were discussed to provide a deep understanding of the role steel fiber played in the reinforcement. The experimental results showed that the flexural strength increased by 282% to 26.1MP, and the compressive strength also reached 104.5Mpa. A high tensile ductility, appreciable bending toughness, and strain-hardening behavior can be achieved with steel fiber incorporation. In addition, it has an advantage over the OPC-based steel fiber-reinforced 3D printing materials given in the existing literature (flexural strength 15 Mpa); It is also superior to the tensile strength (<6Mpa) of current geopolymer fiber reinforcements used for 3D printing. It is anticipated that the development of this 3D printable steel fiber reinforced ‘one-part’ geopolymer will be used to meet high tensile strength requirements for printing scenarios.Keywords: 3D printing concrete, mechanical anisotropy, micro-pore structure, printing technology
Procedia PDF Downloads 78678 Animal Welfare through Stockmanship Competence and Its Relationship to Productivity and Economic Profitability: The Case of Backyard Goat Production in the Philippines
Authors: M. J. Alcedo, K. Ito, K. Maeda
Abstract:
A stockperson has a significant influence on the productivity and welfare of their animals. This influence may be good or bad depending on their stockmanship competence. In this study, stockmanship competence (SC) is defined as the capacity of the stockperson to ensure the welfare of their animals by providing their animal’s needs. The study was conducted to evaluate the stockmanship competence of backyard goat raisers and to examine its relationship to productivity and economic profitability. This was made possible by interviewing 101 backyard goat raisers who have undergone farmer livestock school on integrated goat management (FLS IGM) in Region I, Philippines on September 3-30, 2012 and March 4-17, 2013. Secondary data needed were gathered from the local government agencies involved. Data on stockmanship, goat productivity and farmer’s income before and after attending FLS-IGM were gathered through a semi-structured interview. Questions for stockamnship were based on the Philippine recommends on goat production, tips on goat raising and other scientific literature. Stockmanship competence index score (SCIS) was computed by summing the raw scores derived from each components of SC divided by the total number of components. Pearson correlation through SPSS was used to see the relationship between SC, productivity and income. Result showed that majority raised native and upgraded goats. The computed mean SCIS before and after undergoing FLS-IGM was 38.53% and 75.81%, respectively, an improvement of 49.17%. Both index scores resulted in significant differences in productivity and income. The median mature weight and mortality rate of goats before FLS-IGM, where SC was low, was 14 kg and 50% respectively. On the other hand, after stockmanship had improved, the median mature weight increased to 19 kgs and mortality rate decreased to 11.11%. Likewise, fewer goat diseases were observed by farmers as compared before. With regards to income, there was 127.34% difference on the median net income derived by farmers. Result implies that improved stockmanship competence can lead not only to increased productivity and income of backyard goat raisers but also welfare of the animal.Keywords: stockmanship, backyard goat production, animal welfare, Philippines
Procedia PDF Downloads 322677 Evaluating the Radiation Dose Involved in Interventional Radiology Procedures
Authors: Kholood Baron
Abstract:
Radiologic interventional studies use fluoroscopy imaging guidance to perform both diagnostic and therapeutic procedures. These could result in high radiation doses being delivered to the patients and also to the radiology team. This is due to the prolonged fluoroscopy time and the large number of images taken, even when dose-minimizing techniques and modern fluoroscopic tools are applied. Hence, these procedures are part of the everyday routine of interventional radiology doctors, assistant nurses, and radiographers. Thus, it is important to estimate the radiation exposure dose they received in order to give objective advice and reduce both patient and radiology team radiation exposure dose. The aim of this study was to find out the total radiation dose reaching the radiologist and the patient during an interventional procedure and to determine the impact of certain parameters on the patient dose. Method: The radiation dose was measured by TLD devices (thermoluminescent dosimeter; radiation dosimeter device). Physicians, patients, nurses, and radiographers wore TLDs during 12 interventional radiology procedures performed in two hospitals, Mubarak and Chest Hospital. This study highlights the need for interventional radiologists to be mindful of the radiation doses received by both patients and medical staff during interventional radiology procedures. The findings emphasize the impact of factors such as fluoroscopy duration and the number of images taken on the patient dose. By raising awareness and providing insights into optimizing techniques and protective measures, this research contributes to the overall goal of reducing radiation doses and ensuring the safety of patients and medical staff.Keywords: dosimetry, radiation dose, interventional radiology procedures, patient radiation dose
Procedia PDF Downloads 114676 Epigastric Pain in Emergency Room: Median Arcuate Ligament Syndrome
Authors: Demet Devrimsel Dogan, Ecem Deniz Kirkpantur, Muharrem Dogan, Ahmet Aykut, Ebru Unal Akoglu, Ozge Ecmel Onur
Abstract:
Introduction: Median Arcuate Ligament Syndrome (MALS) is a rare cause of chronic abdominal pain due to external compression of the celiac trunk by a fibrous arch that unites diaphragmatic crura on each side of the aortic hiatus. While 10-24% of the population may suffer from compression of celiac trunk, it rarely causes patients to develop symptoms. The typical clinical triad of symptoms includes postprandial epigastric pain, weight loss and vomiting. The diagnosis can be made using thin section multi-detector computed tomography (CT) scans which delineate the ligament and the compressed vessel. The treatment of MALS is aimed at relieving the compression of the celiac artery to restore adequate blood flow through the vessel and neurolysis to address chronic pain. Case: A 68-year-old male presented to our clinic with acute postprandial epigastric pain. This was patients’ first attack, and the pain was the worst pain of his life. The patient did not have any other symptoms like nausea, vomiting, chest pain or dyspnea. In his medical history, the patient has had an ischemic cerebrovascular stroke 5 years ago which he recovered with no sequel, and he was using 75 mg clopidogrel and 100 mg acetylsalicylic acid. He was not using any other medication and did not have a story of cardiovascular disease. His vital signs were stable (BP:113/72 mmHg, Spo2:97, temperature:36.3°C, HR:90/bpm). In his electrocardiogram, there was ST depression in leads II, III and AVF. In his physical examination, there was only epigastric tenderness, other system examinations were normal. Physical examination through his upper gastrointestinal system showed no bleeding. His laboratory results were as follows: creatinine:1.26 mg/dL, AST:42 U/L, ALT:17 U/L, amylase:78 U/L, lipase:26 U/L, troponin:10.3 pg/ml, WBC:28.9 K/uL, Hgb:12.7 gr/dL, Plt:335 K/uL. His serial high-sensitive troponin levels were also within normal limits, his echocardiography showed no segmental wall motion abnormalities, an acute myocardial infarction was excluded. In his abdominal ultrasound, no pathology was founded. Contrast-enhanced abdominal CT and CT angiography reported ‘thickened diaphragmatic cruras are compressing and stenosing truncus celiacus superior, this is likely compatible with MALS’. The patient was consulted to general surgery, and they admitted the patient for laparoscopic ligament release. Results: MALS is a syndrome that causes postprandial pain, nausea and vomiting as its most common symptoms. Affected patients are normally young, slim women between the ages of 30 and 50 who have undergone extensive examinations to find the source of their symptoms. To diagnose MALS, other underlying pathologies should initially be excluded. The gold standard is aortic angiography. Although diagnosis and treatment of MALS are unclear, symptom resolution has been achieved with multiple surgical modalities, including open, laparoscopic or robotic ligament release as well as celiac ganglionectomy, which often requires celiac artery revascularisation.Keywords: differential diagnosis, epigastric pain, median arcuate ligament syndrome, celiac trunk
Procedia PDF Downloads 261675 Magnesium Alloys for Biomedical Applications Processed by Severe Plastic Deformation
Authors: Mariana P. Medeiros, Amanda P. Carvallo, Augusta Isaac, Milos Janecek, Peter Minarik, Mayerling Martinez Celis, Roberto. R. Figueiredo
Abstract:
The effect of high pressure torsion processing on mechanical properties and corrosion behavior of pure magnesium and Mg-Zn, Mg-Zn-Ca, Mg-Li-Y, and Mg-Y-RE alloys is investigated. Micro-tomography and SEM characterization are used to estimate corrosion rate and evaluate non-uniform corrosion features. The results show the severe plastic deformation processing improves the strength of all magnesium alloys, but deformation localization can take place in the Mg-Zn-Ca and Mg-Y-RE alloys. The occurrence of deformation localization is associated with low strain rate sensitivity in these alloys and with severe corrosion localization. Pure magnesium and Mg-Zn and Mg-Li-Y alloys display good corrosion resistance with low corrosion rate and maintained integrity after 28 days of immersion in Hank`s solution.Keywords: magnesium alloys, severe plastic deformation, corrosion, biodegradable alloys
Procedia PDF Downloads 113674 Urban Impervious and its Impact on Storm Water Drainage Systems
Authors: Ratul Das, Udit Narayan Das
Abstract:
Surface imperviousness in urban area brings significant changes in storm water drainage systems and some recent studies reveals that the impervious surfaces that passes the storm water runoff directly to drainage systems through storm water collection systems, called directly connected impervious area (DCIA) is an effective parameter rather than total impervious areas (TIA) for computation of surface runoff. In the present study, extension of DCIA and TIA were computed for a small sub-urban area of Agartala, the capital of state Tripura. Total impervious surfaces covering the study area were identified on the existing storm water drainage map from landuse map of the study area in association with field assessments. Also, DCIA assessed through field survey were compared to DCIA computed by empirical relationships provided by other investigators. For the assessment of DCIA in the study area two methods were adopted. First, partitioning the study area into four drainage sub-zones based on average basin slope and laying of existing storm water drainage systems. In the second method, the entire study area was divided into small grids. Each grid or parcel comprised of 20m× 20m area. Total impervious surfaces were delineated from landuse map in association with on-site assessments for efficient determination of DCIA within each sub-area and grid. There was a wide variation in percent connectivity of TIA across each sub-drainage zone and grid. In the present study, total impervious area comprises 36.23% of the study area, in which 21.85% of the total study area is connected to storm water collection systems. Total pervious area (TPA) and others comprise 53.20% and 10.56% of the total area, respectively. TIA recorded by field assessment (36.23%) was considerably higher than that calculated from the available land use map (22%). From the analysis of recoded data, it is observed that the average percentage of connectivity (% DCIA with respect to TIA) is 60.31 %. The analysis also reveals that the observed DCIA lies below the line of optimal impervious surface connectivity for a sub-urban area provided by other investigators and which indicate the probable reason of water logging conditions in many parts of the study area during monsoon period.Keywords: Drainage, imperviousness, runoff, storm water.
Procedia PDF Downloads 351673 Soliton Solutions in (3+1)-Dimensions
Authors: Magdy G. Asaad
Abstract:
Solitons are among the most beneficial solutions for science and technology for their applicability in physical applications including plasma, energy transport along protein molecules, wave transport along poly-acetylene molecules, ocean waves, constructing optical communication systems, transmission of information through optical fibers and Josephson junctions. In this talk, we will apply the bilinear technique to generate a class of soliton solutions to the (3+1)-dimensional nonlinear soliton equation of Jimbo-Miwa type. Examples of the resulting soliton solutions are computed and a few solutions are plotted.Keywords: Pfaffian solutions, N-soliton solutions, soliton equations, Jimbo-Miwa
Procedia PDF Downloads 453672 Inverse Problem Method for Microwave Intrabody Medical Imaging
Authors: J. Chamorro-Servent, S. Tassani, M. A. Gonzalez-Ballester, L. J. Roca, J. Romeu, O. Camara
Abstract:
Electromagnetic and microwave imaging (MWI) have been used in medical imaging in the last years, being the most common applications of breast cancer and stroke detection or monitoring. In those applications, the subject or zone to observe is surrounded by a number of antennas, and the Nyquist criterium can be satisfied. Additionally, the space between the antennas (transmitting and receiving the electromagnetic fields) and the zone to study can be prepared in a homogeneous scenario. However, this may differ in other cases as could be intracardiac catheters, stomach monitoring devices, pelvic organ systems, liver ablation monitoring devices, or uterine fibroids’ ablation systems. In this work, we analyzed different MWI algorithms to find the most suitable method for dealing with an intrabody scenario. Due to the space limitations usually confronted on those applications, the device would have a cylindrical configuration of a maximum of eight transmitters and eight receiver antennas. This together with the positioning of the supposed device inside a body tract impose additional constraints in order to choose a reconstruction method; for instance, it inhabitants the use of well-known algorithms such as filtered backpropagation for diffraction tomography (due to the unusual configuration with probes enclosed by the imaging region). Finally, the difficulty of simulating a realistic non-homogeneous background inside the body (due to the incomplete knowledge of the dielectric properties of other tissues between the antennas’ position and the zone to observe), also prevents the use of Born and Rytov algorithms due to their limitations with a heterogeneous background. Instead, we decided to use a time-reversed algorithm (mostly used in geophysics) due to its characteristics of ignoring heterogeneities in the background medium, and of focusing its generated field onto the scatters. Therefore, a 2D time-reversed finite difference time domain was developed based on the time-reversed approach for microwave breast cancer detection. Simultaneously an in-silico testbed was also developed to compare ground-truth dielectric properties with corresponding microwave imaging reconstruction. Forward and inverse problems were computed varying: the frequency used related to a small zone to observe (7, 7.5 and 8 GHz); a small polyp diameter (5, 7 and 10 mm); two polyp positions with respect to the closest antenna (aligned or disaligned); and the (transmitters-to-receivers) antenna combination used for the reconstruction (1-1, 8-1, 8-8 or 8-3). Results indicate that when using the existent time-reversed method for breast cancer here for the different combinations of transmitters and receivers, we found false positives due to the high degrees of freedom and unusual configuration (and the possible violation of Nyquist criterium). Those false positives founded in 8-1 and 8-8 combinations, highly reduced with the 1-1 and 8-3 combination, being the 8-3 configuration de most suitable (three neighboring receivers at each time). The 8-3 configuration creates a region-of-interest reduced problem, decreasing the ill-posedness of the inverse problem. To conclude, the proposed algorithm solves the main limitations of the described intrabody application, successfully detecting the angular position of targets inside the body tract.Keywords: FDTD, time-reversed, medical imaging, microwave imaging
Procedia PDF Downloads 127671 Study the Influence of the Type of Cast Iron Chips on the Quality of Briquettes Obtained with Controlled Impact
Authors: Dimitar N. Karastoianov, Stanislav D. Gyoshev, Todor N. Penchev
Abstract:
Preparation of briquettes of metal chips with good density and quality is of great importance for the efficiency of this process. In this paper are presented the results of impact briquetting of grey cast iron chips with rectangular shape and dimensions 15x25x1 mm. Density and quality of briquettes of these chips are compared with those obtained in another work of the authors using cast iron chips with smaller sizes. It has been found that by using a rectangular chips with a large size are produced briquettes with a very low density and poor quality. From the photographs taken by X-ray tomography, it is clear that the reason for this is the orientation of the chip in the peripheral wall of the briquettes, which does not allow of the air to escape from it. It was concluded that in order to obtain briquettes of cast iron chips with a large size, these chips must first be ground, for example in a small ball mill.Keywords: briquetting, chips, impact, rocket engine
Procedia PDF Downloads 525