Search results for: fracture pressure
4289 Consolidation of Carbonyl Nickel Powders by Hot Pressing
Authors: Ridvan Yamanoglu, Ismail Daoud
Abstract:
In the current study, carbonyl nickel powders were sintered by uniaxial hot pressing technique. Loose starting powders were poured directly into a graphite die with a 15.4 mm inner diameter. Two graphite punches with an outer diameter of 15 mm were inserted into the die; then the powders were sintered at different sintering temperatures, holding times and pressure conditions. The sintered samples were polished and examined by optical microscopy. Hardness and bending behavior of the sintered samples were investigated in order to determine the mechanical properties of the sintered nickel samples. To carried out the friction properties of the produced samples wear tests were studied using a pin on disc tribometer. Load and distance were selected as wear test parameters. The fracture surface of the samples after bending test was also carried out by using scanning electron microscopy.Keywords: nickel powder, sintering, hot press, mechanical properties
Procedia PDF Downloads 1684288 Trabecular Bone Radiograph Characterization Using Fractal, Multifractal Analysis and SVM Classifier
Authors: I. Slim, H. Akkari, A. Ben Abdallah, I. Bhouri, M. Hedi Bedoui
Abstract:
Osteoporosis is a common disease characterized by low bone mass and deterioration of micro-architectural bone tissue, which provokes an increased risk of fracture. This work treats the texture characterization of trabecular bone radiographs. The aim was to analyze according to clinical research a group of 174 subjects: 87 osteoporotic patients (OP) with various bone fracture types and 87 control cases (CC). To characterize osteoporosis, Fractal and MultiFractal (MF) methods were applied to images for features (attributes) extraction. In order to improve the results, a new method of MF spectrum based on the q-stucture function calculation was proposed and a combination of Fractal and MF attributes was used. The Support Vector Machines (SVM) was applied as a classifier to distinguish between OP patients and CC subjects. The features fusion (fractal and MF) allowed a good discrimination between the two groups with an accuracy rate of 96.22%.Keywords: fractal, micro-architecture analysis, multifractal, osteoporosis, SVM
Procedia PDF Downloads 3924287 The Effect of Taekwondo on Plantar Pressure Distribution and Arch Index
Authors: Maryam Kakavand, Samira Entezari, Sara Khoshjamalfekri, Raghad Mimar
Abstract:
The objective of this study is 1) to compare elite female and beginner taekwondo players in terms of plantar pressure distribution, vertical ground reaction force, contact area, mean pressure, and right and left longitudinal arches, and 2) to compare preferred and non-preferred limbs among elite players. To the best of authors’ knowledge, as of yet, there is no information available about the plantar pressure distribution and arch index among taekwondo players. Material and Methods: An analytical-comparative research method is applied. Therefore seven elite athletes and eight novice athletes were selected. The emed-C50 platform was used to assess plantar pressure distribution, vertical ground reaction force, contact area, mean pressure of different areas, and planter longitudinal arch in a second step protocol. Independent t-test and dependent t-test were used at a level of 0.05 to compare the elites and beginners' right and left feet, and preferred and non-preferred limbs among elite athletes, respectively. Results: In comparing the right and left limbs of elite and beginner groups, findings indicate that there is only a significant difference in the mean pressure of the first metatarsal of the right foot. Findings also showed a significant difference in the contact area of the toes 3, 4, 5 regions between elites’ preferred and non-preferred limbs. However, no significant difference was found between the two groups’ right and left limbs and elites’ preferred and non-preferred limbs in terms of pressure distribution, vertical ground reaction force, and arch index. Conclusion: It seems that taekwondo exercises have affected pressure distribution patterns among advanced players causing some differences in their planter pressure distribution pattern when compared to that of beginners. Therefore, taekwondo exercises may be a factor contributing to asymmetry performance in preferred and non-preferred limbs.Keywords: planter pressure, arch index, taekwondo, elite
Procedia PDF Downloads 1544286 A Study of the Prevalence of Hypertension and Pre Hypertension in Adolescence Age between 10-17 in Ahvaz (2008-2009)
Authors: Armaghan Moravej Aleali, Seyed Mahmoud Latifi, Homeira Rashidi
Abstract:
Objective: High blood pressure in a risk factor for some disease like stroke, coronary heart disease, and renal failure. High blood pressure in children is an increasing health problem. The aim of this present was to determine prevalence of hypertension and pre-hypertension age between 10 to 17 years old. Material & Methods: This descriptive-analytic study was conducted using multiphase sampling method in Ahvaz (Southwest of Iran). A questionnaire include: height, weight, and body mass index, systolic and diastolic blood pressures filled for each participant. Blood pressure was measured twice for each person. For the diagnosis of hypertension, the fourth report of the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents of the National Health Institute of United States was used. Results: The subject participants of the study were 1707children and adolescents including 922 boys (54%) and 785 girls 46%). The prevalence of high blood pressure was 1.7% (boys 2.5% girls 0.8%). The prevalence of pre-hypertension was 9 % (7.6% in boys, 10.6% in girls). The mean systolic and diastolic blood pressures increased with increasing body mass index. Conclusion: In this study, the prevalence of high blood pressure was found to be lower than other studies in our country. The prevalence of the high blood pressure in boys was significantly higher than girls. This study, like other studies, showed a high correlation between being overweight and an increase in systolic and diastolic blood pressure.Keywords: hypertension, pre-hypertension, childhood, adolescence
Procedia PDF Downloads 4604285 Fatigue Behavior of Dissimilar Welded Monel400 and SS316 by Friction Stir Welding
Authors: Aboozar Aghaei, Kamran Dehghani
Abstract:
In the present work, the dissimilar Monel400 and SS316 were joined by friction stir welding (FSW). The applied rotating speed was 400 rpm, whereas the traverse speed varied between 50 and 150 mm/min. At a constant rotating speed, the sound welds were obtained at the welding speeds of 50 and 100 mm/min. However, a groove-like defect was formed when the welding speed exceeded 100 mm/min. The mechanical properties of the joints were evaluated using tensile and fatigue tests. The fatigue strength of dissimilar FSWed specimens was higher than that of both Monel400 and SS316. To study the failure behavior of FSWed specimens, the fracture surfaces were analyzed using a scanning electron microscope (SEM). The failure analysis indicates that different mechanisms may contribute to the fracture of welds. This was attributed to the dissimilar characteristics of dissimilar materials exhibiting different failure behaviors.Keywords: frictions stir welding, stainless steel, Monel400, mechanical properties
Procedia PDF Downloads 874284 Ultrasonographic Study of Normal Scapula in Horse
Authors: Mohamad Saeed Ahrari-Khafi, Abutorab Tabatabai-Naini, Niloofar Ajvadi
Abstract:
Scapular fracture is not common in horses, due to the proper protection of scapular muscles. However, if it happens, it can cause lameness in horses. Because of the overlapping of the scapula on the contralateral scapula and the thorax, usually radiography cannot be helpful in evaluation, except in small amount of its ventral part. Although ultrasonography is mainly used for diagnosis of soft tissue injuries, it also can be used for evaluation of bone surface abnormalities. This study was intended to document the normal ultrasonographic appearance of the equine scapula. Right forelimb of six horses was used. To facilitate the image assessment, a zoning system was developed. Ultrasonography was performed by using a 5-11 MHz linear array transducer. Ultrasonographic anatomy of scapula in different parts and planes was imaged and documented, hoping to help practitioners to diagnose fractures and injuries. Results showed that ultrasonography is capable to depict different parts of the scapula and regional muscles, and can be used for detecting fractures and other abnormalities.Keywords: horse, scapula, scapular fracture, ultrasonography
Procedia PDF Downloads 3054283 A Rare Case of Prolonged Pressure Rise Following Selective Laser Trabeculoplasty
Authors: Aneesha Fonseca, Arij Daas, Muhammed Abdulkader
Abstract:
Transient intraocular pressure (IOP) rise is a common occurrence after glaucoma laser procedures. However, this pressure spike usually lasts only a few days. We describe a case of a 60-year-old Caucasian gentleman who underwent selective laser trabeculoplasty (SLT) in both eyes for ocular hypertension previously treated with Bimatoprost and Timolol and developed a sustained raised IOP. His IOP rose from 34 and 33 mmHg pre-laser to 48 and 42 mmHg after SLT in the right and left eye, respectively. Even after maximum medical therapy (Bimatoprost, Timolol, Brinzolamide Apraclonidine, and oral Acetozolamide), his IOP remained at 32 and 28mmHg. A provisional diagnosis of trabeculitis was made, and topical Ketorolac was commenced in addition to the IOP-lowering medications. Within a week, his IOP came down to 21 and 18mmHg in the right and left eye, respectively.Keywords: complications, selective laser trabeculoplasty, sustained pressure rise, trabeculitis
Procedia PDF Downloads 1004282 First Principles Study of Structural and Elastic Properties of BaWO4 Scheelite Phase Structure under Pressure
Authors: Abdennour Benmakhlouf, Abdelouahab Bentabet
Abstract:
In this paper, we investigated the athermal pressure behavior of the structural and elastic properties of scheelite BaWO4 phase up to 7 GPa using the ab initio pseudo-potential method. The calculated lattice parameters pressure relation have been compared with the experimental values and found to be in good agreement with these results. Moreover, we present for the first time the investigation of the elastic properties of this compound using the density functional perturbation theory (DFPT). It is shown that this phase is mechanically stable up to 7 GPa after analyzing the calculated elastic constants. Other relevant quantities such as bulk modulus, pressure derivative of bulk modulus, shear modulus; Young’s modulus, Poisson’s ratio, anisotropy factors, Debye temperature and sound velocity have been calculated. The obtained results, which are reported for the first time to the best of the author’s knowledge, can facilitate assessment of possible applications of the title material.Keywords: pseudo-potential method, pressure, structural and elastic properties, scheelite BaWO4 phase
Procedia PDF Downloads 4394281 Magnitude of Infection and Associated factor in Open Tibial Fractures Treated Operatively at Addis Ababa Burn Emergency and Trauma Center April, 2023
Authors: Tuji Mohammed Sani
Abstract:
Back ground: An open tibial fracture is an injury where the fractured bone directly communicates with the outside environment. Due to the specific anatomical features of the tibia (limited soft tissue coverage), more than quarter of its fractures are classified as open, representing the most common open long-bone injuries. Open tibial fractures frequently cause significant bone comminution, periosteal stripping, soft tissue loss, contamination and are prone to bacterial entry with biofilm formation, which increases the risk of deep bone infection. Objective: The main objective of the study was to determine Prevalence of infection and its associated factors in surgically treated open tibial fracture in Addis Ababa Burn Emergency and Trauma (AaBET) center. Method: A facility based retrospective cross-sectional study was conducted among patient treated for open tibial fracture at AaBET center from September 2018 to September 2021. The data was collected from patient’s chart using structured data collection form, and Data was entered and analyzed using SPSS version 26. Bivariable and multiple binary logistic regression were fitted. Multicollinearity was checked among candidate variables using variance inflation factor and tolerance, which were less than 5 and greater than 0.2, respectively. Model adequacy were tested using Hosmer-Lemeshow goodness of fitness test (P=0.711). AOR at 95% CI was reported, and P-value < 0.05 was considered statistically significant. Result: This study found that 33.9% of the study participants had an infection. Initial IV antibiotic time (AOR=2.924, 95% CI:1.160- 7.370) and time of wound closure from injury (AOR=3.524, 95% CI: 1.798-6.908), injury to admission time (AOR=2.895, 95% CI: 1.402 – 5.977). and definitive fixation method (AOR=0.244, 95% CI: 0.113 – 0.4508) were the factors found to have a statistically significant association with the occurrence of infection. Conclusion: The rate of infection in open tibial fractures indicates that there is a need to improve the management of open tibial fracture treated at AaBET center. Time from injury to admission, time from injury to first debridement, wound closure time, and initial Intra Venous antibiotic time from the injury are an important factor that can be readily amended to improve the infection rate. Whether wound closed before seven days or not were more important factor associated with occurrences of infection.Keywords: infection, open tibia, fracture, magnitude
Procedia PDF Downloads 824280 Influence of Specimen Geometry (10*10*40), (12*12*60) and (5*20*120), on Determination of Toughness of Concrete Measurement of Critical Stress Intensity Factor: A Comparative Study
Authors: M. Benzerara, B. Redjel, B. Kebaili
Abstract:
The cracking of the concrete is a more crucial problem with the development of the complex structures related to technological progress. The projections in the knowledge of the breaking process make it possible today for better prevention of the risk of the fracture. The breaking strength brutal of a quasi-fragile material like the concrete called Toughness is measured by a breaking value of the factor of the intensity of the constraints K1C for which the crack is propagated, it is an intrinsic property of the material. Many studies reported in the literature treating of the concrete were carried out on specimens which are in fact inadequate compared to the intrinsic characteristic to identify. We started from this established fact, in order to compare the evolution of the parameter of toughness K1C measured by calling upon ordinary concrete specimens of three prismatic geometries different (10*10*40) Cm3, (12*12*60) Cm3 & (5*20*120) Cm3 containing from the side notches various depths simulating of the cracks was set up.The notches are carried out using triangular pyramidal plates into manufactured out of sheet coated placed at the center of the specimens at the time of the casting, then withdrawn to leave the trace of a crack. The tests are carried out in 3 points bending test in mode 1 of fracture, by using the techniques of mechanical fracture. The evolution of the parameter of toughness K1C measured with the three geometries specimens gives almost the same results. They are acceptable and return in the beach of the results determined by various researchers (toughness of the ordinary concrete turns to the turn of the 1 MPa √m). These results inform us about the presence of an economy on the level of the geometry specimen (5*20*120) Cm3, therefore, to use plates specimens later if one wants to master the toughness of this material complexes, astonishing but always essential that is the concrete.Keywords: concrete, fissure, specimen, toughness
Procedia PDF Downloads 2984279 Mathematical Modeling Pressure Losses of Trapezoidal Labyrinth Channel and Bi-Objective Optimization of the Design Parameters
Authors: Nina Philipova
Abstract:
The influence of the geometric parameters of trapezoidal labyrinth channel on the pressure losses along the labyrinth length is investigated in this work. The impact of the dentate height is studied at fixed values of the dentate angle and the dentate spacing. The objective of the work presented in this paper is to derive a mathematical model of the pressure losses along the labyrinth length depending on the dentate height. The numerical simulations of the water flow movement are performed by using Commercial codes ANSYS GAMBIT and FLUENT. Dripper inlet pressure is set up to be 1 bar. As a result, the mathematical model of the pressure losses is determined as a second-order polynomial by means Commercial code STATISTIKA. Bi-objective optimization is performed by using the mean algebraic function of utility. The optimum value of the dentate height is defined at fixed values of the dentate angle and the dentate spacing. The derived model of the pressure losses and the optimum value of the dentate height are used as a basis for a more successful emitter design.Keywords: drip irrigation, labyrinth channel hydrodynamics, numerical simulations, Reynolds stress model
Procedia PDF Downloads 1544278 Electronic/Optoelectronic Property Tuning in Two-Dimensional Transition Metal Dichalcogenides via High Pressure
Authors: Juan Xia, Jiaxu Yan, Ze Xiang Shen
Abstract:
The tuneable interlayer interactions in two-dimensional (2D) transition metal dichlcogenides (TMDs) offer an exciting platform for exploring new physics and applications by material variety, thickness, stacking sequence, electromagnetic filed, and stress/strain. Compared with the five methods mentioned above, high pressure is a clean and powerful tool to induce dramatic changes in lattice parameters and physical properties for 2D TMD materials. For instance, high pressure can strengthen the van der Waals interactions along c-axis and shorten the covalent bonds in atomic plane, leading to the typical first-order structural transition (2Hc to 2Ha for MoS2), or metallization. In particular, in the case of WTe₂, its unique symmetry endows the significant anisotropy and the corresponding unexpected properties including the giant magnetoresistance, pressure-induced superconductivity and Weyl semimetal states. Upon increasing pressure, the Raman peaks for WTe₂ at ~120 cm⁻¹, are gradually red-shifted and totally suppressed above 10 GPa, attributed to the possible structural instability of orthorhombic Td phase under high pressure and phase transition to a new monoclinic T' phase with inversion symmetry. Distinct electronic structures near Fermi level between the Td and T' phases may pave a feasible way to achieve the Weyl state tuning in one material without doping.Keywords: 2D TMDs, electronic property, high pressure, first-principles calculations
Procedia PDF Downloads 2314277 A Physiological Approach for Early Detection of Hemorrhage
Authors: Rabie Fadil, Parshuram Aarotale, Shubha Majumder, Bijay Guargain
Abstract:
Hemorrhage is the loss of blood from the circulatory system and leading cause of battlefield and postpartum related deaths. Early detection of hemorrhage remains the most effective strategy to reduce mortality rate caused by traumatic injuries. In this study, we investigated the physiological changes via non-invasive cardiac signals at rest and under different hemorrhage conditions simulated through graded lower-body negative pressure (LBNP). Simultaneous electrocardiogram (ECG), photoplethysmogram (PPG), blood pressure (BP), impedance cardiogram (ICG), and phonocardiogram (PCG) were acquired from 10 participants (age:28 ± 6 year, weight:73 ± 11 kg, height:172 ± 8 cm). The LBNP protocol consisted of applying -20, -30, -40, -50, and -60 mmHg pressure to the lower half of the body. Beat-to-beat heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean aerial pressure (MAP) were extracted from ECG and blood pressure. Systolic amplitude (SA), systolic time (ST), diastolic time (DT), and left ventricle Ejection time (LVET) were extracted from PPG during each stage. Preliminary results showed that the application of -40 mmHg i.e. moderate stage simulated hemorrhage resulted significant changes in HR (85±4 bpm vs 68 ± 5bpm, p < 0.01), ST (191 ± 10 ms vs 253 ± 31 ms, p < 0.05), LVET (350 ± 14 ms vs 479 ± 47 ms, p < 0.05) and DT (551 ± 22 ms vs 683 ± 59 ms, p < 0.05) compared to rest, while no change was observed in SA (p > 0.05) as a consequence of LBNP application. These findings demonstrated the potential of cardiac signals in detecting moderate hemorrhage. In future, we will analyze all the LBNP stages and investigate the feasibility of other physiological signals to develop a predictive machine learning model for early detection of hemorrhage.Keywords: blood pressure, hemorrhage, lower-body negative pressure, LBNP, machine learning
Procedia PDF Downloads 1674276 Preparation and Characterization of Hybrid Perovskite Enhanced with PVDF for Pressure Sensing
Authors: Mohamed E. Harb, Enas Moustafa, Shaker Ebrahim, Moataz Soliman
Abstract:
In this paper pressure detectors were synthesized and characterized using hybrid perovskite/PVDF composites as an active layer. Methylammonium lead iodide (MAPbI₃) was synthesized from methylammonium iodide (MAI) (CH₃NH₃I) and lead iodide (PbI₂). Composites of perovskite/PVDF using different weight ratio were prepared as the active material. PVDF with weights percentages of 6%, 8%, and 10% was used. All prepared materials were investigated by x-ray diffraction (XRD), Fourier transforms infrared spectrum (FTIR) and scanning electron microscopy (SEM). A Versastat 4 Potentiostat Galvanostat instrument was used to perform the current-voltage characteristics of the fabricated sensors. The pressure sensors exhibited a voltage increase with applying different forces. Also, the current-voltage characteristics (CV) showed different effects with applying forces. So, the results showed a good pressure sensing performance.Keywords: perovskite semiconductor, hybrid perovskite, PVDF, Pressure sensing
Procedia PDF Downloads 2074275 The Pressure Effect and First-Principles Study of Strontium Chalcogenides SrS
Authors: Benallou Yassine, Amara Kadda, Bouazza Boubakar, Soudini Belabbes, Arbouche Omar, M. Zemouli
Abstract:
The study of the pressure effect on the materials, their functionality and their properties is very important, insofar as it provides the opportunity to identify others applications such the optical properties in the alkaline earth chalcogenides, as like the SrS. Here we present the first-principles calculations which have been performed using the full potential linearized augmented plane wave method (FP-LAPW) within the Generalized Gradient Approximation developed by Perdew–Burke–Ernzerhor for solids (PBEsol). The calculated structural parameters like the lattice parameters, the bulk modulus B and their pressure derivative B' are in reasonable agreement with the available experimental and theoretical data. In addition, the elastic properties such as elastic constants (C11, C12, and C44), the shear modulus G, the Young modulus E, the Poisson’s ratio ν and the B/G ratio are also given. The treatments of exchange and correlation effects were done by the Tran-Blaha modified Becke-Johnson (TB-mBJ) potential for the electronic. The pressure effect on the electronic properties was visualized by calculating the variations of the gap as a function of pressure. The obtained results are compared to available experimental data and to other theoretical calculationsKeywords: SrS, GGA-PBEsol+TB-MBJ, density functional, Perdew–Burke–Ernzerhor, FP-LAPW, pressure effect
Procedia PDF Downloads 5694274 Experimental and Comparative Study of Composite Thin Cylinder Subjected to Internal Pressure
Authors: Hakim S. Sultan Aljibori
Abstract:
An experimental procedure is developed to study the performance of composite thin wall cylinders subjected to internal pressure loading for investigations of stress distribution through the composite cylinders wall. Three types of fibers were used in this study are; woven roving glass fiber/epoxy, hybrid fiber/epoxy, and Kevlar fiber/epoxy composite specimens were fabricated and tested. All of these specimens subjected to uniformed pressure load using the hydraulic pump. Axial stress is identified, and values were found after collecting all the results. Comparison between the deferent types of specimens was done. Thus, the present investigation concludes the efficient and effective composite cylinder experimentally and provides a considerable advantage for using woven roving fibers in pressure vessels applications.Keywords: stress distribution, composite material, internal pressure, glass fiber, hybrid fiber
Procedia PDF Downloads 1624273 An Audit on Tracheal Tube Cuff Pressure Check and Monitoring during Current Practice
Authors: Mahmoud Hassanin, Roshan Thawale, Kiran Yelamati
Abstract:
Background: During current practice, intraoperative regular endotracheal cuff pressure monitoring is not routine, despite the significant number of clinicians interested in checking it after intubation to ensure a good seal and adequate ventilation. Aims and objectives: to highlight that the current practice has no guidance related to regular intra-operative monitoring of the endotracheal tube cuff pressure, which can improve patient safety and post-operative experience. Methods: local department survey was done targeting anaesthetists' current practice, measuring their knowledge and problem awareness to improve patient satisfaction and change the current approach. Results: The participants were not using the manometer, despite their interest in ensuring that the cuff pressure was high enough and there was a proper seal. More than 50% of the participant don't know the ideal range of the endotracheal tube cuff pressure range, and 32% don't know whether it is available or not in the theatre. Despite the previous finding, 100% of the participants used different methods to ensure adequate cuff pressure. The collected data revealed that at least 26% of the participant confirmed that they had seen patients having post-intubation complications. Conclusion: There is an increasing importance placed on quality assurance. Clinical practice varies widely among practitioners, with the only consistency being the omission of cuff manometers during routine intra-operative management, despite their proven benefit and efficacy. Encourage the anaesthetists and ODPs to use cuff pressure manometers. The availability of portable pressure manometers can help to maintain safe cuff pressures in patients requiring endotracheal intubation.Keywords: endotracheal cuff pressure, intra-operative monitoring, current practice, patient satisfaction
Procedia PDF Downloads 1064272 Coupled Effect of Pulsed Current and Stress State on Fracture Behavior of Ultrathin Superalloy Sheet
Authors: Shuangxin Wu
Abstract:
Superalloy ultra-thin-walled components occupy a considerable proportion of aero engines and play an increasingly important role in structural weight reduction and performance improvement. To solve problems such as high deformation resistance and poor formability at room temperature, the introduction of pulse current in the processing process can improve the plasticity of metal materials, but the influence mechanism of pulse current on the forming limit of superalloy ultra-thin sheet is not clear, which is of great significance for determining the material processing window and improving the micro-forming process. The effect of pulse current on the microstructure evolution of superalloy thin plates was observed by optical microscopy (OM) and X-ray diffraction topography (XRT) by applying pulse current to GH3039 with a thickness of 0.2mm under plane strain and uniaxial tensile states. Compared with the specimen without pulse current applied at the same temperature, the internal void volume fraction is significantly reduced, reflecting the non-thermal effect of pulse current on the growth of micro-pores. ED (electrically deforming) specimens have larger and deeper dimples, but the elongation is not significantly improved because the pulse current promotes the void coalescence process, resulting in material fracture. The electro-plastic phenomenon is more obvious in the plane strain state, which is closely related to the effect of stress triaxial degree on the void evolution under pulsed current.Keywords: pulse current, superalloy, ductile fracture, void damage
Procedia PDF Downloads 724271 Reducing the Incidence Rate of Pressure Sore in a Medical Center in Taiwan
Authors: Chang Yu Chuan
Abstract:
Background and Aim: Pressure sore is not only the consequence of any gradual damage of the skin leading to tissue defects but also an important indicator of clinical care. If hospitalized patients develop pressure sores without proper care, it would result in delayed healing, wound infection, increase patient physical pain, prolonged hospital stay and even death, which would have a negative impact on the quality of care and also increase nursing manpower and medical costs. This project is aimed at decreasing the incidence of pressure sore in one ward of internal medicine. Our data showed 53 cases (0.61%) of pressure sore in 2015, which exceeded the average (0.5%) of Taiwan Clinical Performance Indicator (TCPI) for medical centers. The purpose of this project is to reduce the incidence rate of pressure sore in the ward. After data collection and analysis from January to December 2016, the reasons of developing pressure sore were found: 1. Lack of knowledge to prevent pressure among nursing staffs; 2. No relevant courses about preventing pressure ulcers and pressure wound care being held in this unit; 3. Low complete rate of pressure sore care education that family members should receive from nursing staffs; 4. Decompression equipment is not enough; 5. Lack of standard procedures for body-turning and positioning care. After team members brainstorming, several strategies were proposed, including holding in-service education, pressure sore care seed training, purchasing decompression mattress and memory pillows, designing more elements of health education tools, such as health education pamphlet, posters and multimedia films of body-turning and positioning demonstration, formulation and promotion of standard operating procedures. In this way, nursing staffs can understand the body-turning and positioning guidelines for pressure sore prevention and enhance the quality of care. After the implementation of this project, the pressure sore density significantly decreased from 0.61%(53 cases) to 0.45%(28 cases) in this ward. The project shows good results and good example for nurses working at the ward and helps to enhance quality of care.Keywords: body-turning and positioning, incidence density, nursing, pressure sore
Procedia PDF Downloads 2674270 Reservoir Properties Effect on Estimating Initial Gas in Place Using Flowing Material Balance Method
Authors: Yousef S. Kh. S. Hashem
Abstract:
Accurate estimation of initial gas in place (IGIP) plays an important factor in the decision to develop a gas field. One of the methods that are available in the industry to estimate the IGIP is material balance. This method required that the well has to be shut-in while pressure is measured as it builds to average reservoir pressure. Since gas demand is high and shut-in well surveys are very expensive, flowing gas material balance (FGMB) is sometimes used instead of material balance. This work investigated the effect of reservoir properties (pressure, permeability, and reservoir size) on the estimation of IGIP when using FGMB. A gas reservoir simulator that accounts for friction loss, wellbore storage, and the non-Darcy effect was used to simulate 165 different possible causes (3 pressures, 5 reservoir sizes, and 11 permeabilities). Both tubing pressure and bottom-hole pressure were analyzed using FGMB. The results showed that the FGMB method is very sensitive for tied reservoirs (k < 10). Also, it showed which method is best to be used for different reservoir properties. This study can be used as a guideline for the application of the FGMB method.Keywords: flowing material balance, gas reservoir, reserves, gas simulator
Procedia PDF Downloads 1554269 Design of Rigid L-Shaped Retaining Walls
Authors: Ahmed Rouili
Abstract:
Cantilever L-shaped walls are known to be relatively economical as retaining solution. The design starts by proportioning the wall dimensions for which the stability is checked for. A ratio between the lengths of the base and the stem, falling between 0,5 to 0,7, ensure the stability requirements in most cases. However, the displacement pattern of the wall in terms of rotations and translations, and the lateral pressure profile, do not have the same figure for all wall’s proportioning, as it is usually assumed. In the present work, the results of a numerical analysis are presented, different wall geometries were considered. The results show that the proportioning governs the equilibrium between the instantaneous rotation and the translation of the wall-toe, also, the lateral pressure estimation based on the average value between the at-rest and the active pressure, recommended by most design standards, is found to be not applicable for all walls.Keywords: cantilever wall, proportioning, numerical analysis, lateral pressure estimation
Procedia PDF Downloads 3234268 A Robust System for Foot Arch Type Classification from Static Foot Pressure Distribution Data Using Linear Discriminant Analysis
Authors: R. Periyasamy, Deepak Joshi, Sneh Anand
Abstract:
Foot posture assessment is important to evaluate foot type, causing gait and postural defects in all age groups. Although different methods are used for classification of foot arch type in clinical/research examination, there is no clear approach for selecting the most appropriate measurement system. Therefore, the aim of this study was to develop a system for evaluation of foot type as clinical decision-making aids for diagnosis of flat and normal arch based on the Arch Index (AI) and foot pressure distribution parameter - Power Ratio (PR) data. The accuracy of the system was evaluated for 27 subjects with age ranging from 24 to 65 years. Foot area measurements (hind foot, mid foot, and forefoot) were acquired simultaneously from foot pressure intensity image using portable PedoPowerGraph system and analysis of the image in frequency domain to obtain foot pressure distribution parameter - PR data. From our results, we obtain 100% classification accuracy of normal and flat foot by using the linear discriminant analysis method. We observe there is no misclassification of foot types because of incorporating foot pressure distribution data instead of only arch index (AI). We found that the mid-foot pressure distribution ratio data and arch index (AI) value are well correlated to foot arch type based on visual analysis. Therefore, this paper suggests that the proposed system is accurate and easy to determine foot arch type from arch index (AI), as well as incorporating mid-foot pressure distribution ratio data instead of physical area of contact. Hence, such computational tool based system can help the clinicians for assessment of foot structure and cross-check their diagnosis of flat foot from mid-foot pressure distribution.Keywords: arch index, computational tool, static foot pressure intensity image, foot pressure distribution, linear discriminant analysis
Procedia PDF Downloads 4994267 Increasing the Forecasting Fidelity of Current Collection System Operating Capability by Means of Contact Pressure Simulation Modelling
Authors: Anton Golubkov, Gleb Ermachkov, Aleksandr Smerdin, Oleg Sidorov, Victor Philippov
Abstract:
Current collection quality is one of the limiting factors when increasing trains movement speed in the rail sector. With the movement speed growth, the impact forces on the current collector from the rolling stock and the aerodynamic influence increase, which leads to the spread in the contact pressure values, separation of the current collector head from the contact wire, contact arcing and excessive wear of the contact elements. The upcoming trend in resolving this issue is the use of the automatic control systems providing stabilization of the contact pressure value. The present paper considers the features of the contemporary automatic control systems of the current collector’s pressure; their major disadvantages have been stated. A scheme of current collector pressure automatic control has been proposed, distinguished by a proactive influence on undesirable effects. A mathematical model of contact strips wearing has been presented, obtained in accordance with the provisions of the central composition rotatable design program. The analysis of the obtained dependencies has been carried out. The procedures for determining the optimal current collector pressure on the contact wire and the pressure control principle in the pneumatic drive have been described.Keywords: contact strip, current collector, high-speed running, program control, wear
Procedia PDF Downloads 1454266 Rupture Probability of Type of Coarse Aggregate on Fracture Surface of Concrete
Authors: B. Ramakrishna, S. Sivamurthy Reddy
Abstract:
The various types of aggregates such as granite, dolerite, Quartzite, dolomitic limestone, limestone and river gravel were used to produce the concrete with 28-day target compressive strength of 35, 60, and 80 Mpa. The compressive strength of concrete, as well as aggregates, was measured to study the effect of rupture probability of aggregate on the fracture surface of the concrete. Also, the petrographic studies were carried out to study the texture, type of minerals present and their relative proportions in various types of aggregates. The concrete of various grades produced with the same aggregate has shown a rise in RPCA with strength. However, the above relationship has ceased to exist in the concretes of the same grade, made of different types of aggregates. The carbonate aggregates namely Limestone and Dolomitic limestone have produced concrete with higher RPCA irrespective of the strength of concrete. The mode of origin, texture and mineralogical composition of aggregates have a significant impact on their pulse velocity and thereby the pulse velocity of concrete. Procedia PDF Downloads 2944265 Effect of Clinical Parameters on Strength of Reattached Tooth Fragment in Anterior Teeth: Systematic Review and Meta-Analysis
Authors: Neeraj Malhotra, Ramya Shenoy
Abstract:
Objective: To assess the effect of clinical parameters (bonding agent, preparation design & storage media) on the strength of reattached anterior tooth fragment. Methodology: This is a systematic review and meta-analysis for articles referred from MEDLINE, PUBMED, and GOOGLE SCHOLAR. The articles on tooth reattachment and clinical factors affecting fracture strength/bond strength/fracture resistance of the reattached tooth fragment in anterior teeth and published in English from 1999 to 2016 were included for final review. Results: Out of 120 shortlisted articles, 28 articles were included for the systematic review and meta-analysis based on 3 clinical parameters i.e. bonding agent, tooth preparation design & storage media. Forest plot & funnel plots were generated based on individual clinical parameter and their effect on strength of reattached anterior tooth fragment. Results based on analysis suggest combination of both conclusive evidence favoring the experimental group as well as in-conclusive evidence for individual parameter. Conclusion: There is limited evidence as there are fewer articles supporting each parameter in human teeth. Bonding agent had showed better outcome in selected studies.Keywords: bonding agent, bond strength, fracture strength, preparation design, reattachment, storage media
Procedia PDF Downloads 1784264 Blood Pressure Level, Targeted Blood Pressure Control Rate, and Factors Related to Blood Pressure Control in Post-Acute Ischemic Stroke Patients
Authors: Nannapus Saramad, Rewwadee Petsirasan, Jom Suwanno
Abstract:
Background: This retrospective study design was to describe average blood pressure, blood pressure level, target blood pressure control rate post-stroke BP control in the year following discharge from Sichon hospital, Sichon District, Nakhon Si Thammarat province. The secondary data analysis was employed from the patient’s health records with patient or caregiver interview. A total of 232 eligible post-acute ischemic strokes in the year following discharge (2017-2018) were recruited. Methods: Data analyses were applied to identify the relationship values of single variables were determined through univariate analyses: The Chi-square test, Fisher exact test, the variables found to have a p-value < 0.2 were analyzed by the binary logistic regression Results: Most of the patients in this study were men 61.6%, an average age of 65.4 ± 14.8 years. Systolic blood pressure levels were in the grade 1-2 hypertension and diastolic pressure at optimal and normal at all times during the initial treatment through the present. The results revealed 25% among the groups under the age of 60 achieved BP control; 36.3% for older than 60 years group; and 27.9% for diabetic group. The multivariate analysis revealed the final relationship of four significant variables: 1) receiving calcium-channel blocker (p =.027); 2) medication adherence of antihypertensive (p = .024) 3) medication adherence of antiplatelet ( p = .020); and 4) medication behavior ( p = . 010) . Conclusion: The medical nurse and health care provider should promote their adherence to behavior to improve their blood pressure control.Keywords: acute ischemic stroke, target blood pressure control, medication adherence, recurrence stroke
Procedia PDF Downloads 1224263 Simultaneous Measurement of Pressure and Temperature Profile of Lubricating Oil-Film along Orthogonally Displaced Non-Circular Journal Bearing: An Experimental Study
Authors: Amit Singla, Amit Chauhan
Abstract:
The non-circular journal bearings provide better thermal stability and lesser oil-film temperature rise as compared to circular journal bearings. Experimentation on simultaneous measurement of pressure and temperature of lubricated oil-film along the profile of the bearing will help the designer to design journal bearings. In this paper, pressure and temperature of oil-film along orthogonally displaced non-circular journal bearing have been measured on a designed journal bearing test rig. The orthogonal non-circular journal bearing has been fabricated by displacing two circular halves away from the centers in the orthogonal direction. The data acquisition for oil film pressure and temperature has been carried out at journal speed=3000 rpm and by increasing the static radial load from 500 N to 2000 N in steps of 500 N using three different grades of oil (ISOVG 32, 68, and 150) named as oil-1, oil-2, and oil-3 respectively. The results show that the oil-film pressure and temperature increases with increase in radial load and change of lubricating oil towards increasing viscosity. Further, two lobes in the pressure and temperature profiles have been obtained which accounts for better thermal stability as it reduces cavitation zone inside the bearing.Keywords: cavitation, non-circular journal bearing, orthogonally displaced, thermal stability
Procedia PDF Downloads 3514262 Dimensionless Binding Values in the Evaluation of Paracetamol Tablet Formulation
Authors: Abayomi T. Ogunjimi, Gbenga Alebiowu
Abstract:
Mechanical properties of paracetamol tablets containing Neem (Azadirachta indica) gum were compared with standard Acacia gum BP as binder. Two dimensionless binding quantities BEN and BEC were used in assessing the influence of binder type on two mechanical properties, Tensile Strength (TS) and Brittle Fracture Index (BFI). The two quantities were also used to assess the influence of relative density and binder concentration on TS and BFI as well as compare Binding Efficiencies (BE). The result shows that TS is dependent on relative density, binder type and binder concentration while BFI is dependent on the binder type and binder concentration; and that although, the inclusion of NMG in a paracetamol tablet formulation may not enhance the TS of the tablets produced, however it will decrease the tendency of the tablets to cap or laminate. This work concludes that BEN may be useful in quantitative assessment while BEC may be appropriate for qualitative assessment.Keywords: binding efficiency, brittle fracture index, dimensionless binding, tensile strength
Procedia PDF Downloads 2534261 Influence of Stress Relaxation and Hysteresis Effect for Pressure Garment Design
Authors: Chia-Wen Yeh, Ting-Sheng Lin, Chih-Han Chang
Abstract:
Pressure garment has been used to prevent and treat the hypertrophic scars following serious burns since 1970s. The use of pressure garment is believed to hasten the maturation process and decrease the highness of scars. Pressure garment is custom made by reducing circumferential measurement of the patient by 10%~20%, called Reduction Factor. However the exact reducing value used depends on the subjective judgment of the therapist and the feeling of patients throughout the try and error process. The Laplace Law can be applied to calculate the pressure from the dimension of the pressure garment by the circumferential measurements of the patients and the tension profile of the fabrics. The tension profile currently obtained neglects the stress relaxation and hysteresis effect within most elastic fabrics. The purpose of this study was to investigate the influence of the tension attenuation, from stress relaxation and hysteresis effect of the fabrics. Samples of pressure garment were obtained from Sunshine Foundation Organization, a nonprofit organization for burn patients in Taiwan. The wall tension profile of pressure garments were measured on a material testing system. Specimens were extended to 10% of the original length, held for 1 hour for the influence of the stress relaxation effect to take place. Then, specimens were extended to 15% of the original length for 10 seconds, then reduced to 10% to simulate donning movement for the influence of the hysteresis effect to take place. The load history was recorded. The stress relaxation effect is obvious from the load curves. The wall tension is decreased by 8.5%~10% after 60mins of holding. The hysteresis effect is obvious from the load curves. The wall tension is increased slightly, then decreased by 1.5%~2.5% and lower than stress relaxation results after 60mins of holding. The wall tension attenuation of the fabric exists due to stress relaxation and hysteresis effect. The influence of hysteresis is more than stress relaxation. These effect should be considered in order to design and evaluate the pressure of pressure garment more accurately.Keywords: hypertrophic scars, hysteresis, pressure garment, stress relaxation
Procedia PDF Downloads 5124260 A Soil Stabilization Technique on Apa-Hotamiş Conveyance Channel
Authors: Ali Sinan Soğancı
Abstract:
Apa-Hotamış conveyance channel is located within in the boundaries of Konya Regional Directorate of Water Works. This channel transfers the water to the fount of Apa Dam with 17 km length of Blue Channel. Then the water is transmitted with Apa- Hotamış conveyance channel to Hotamış Water Storage. In some places along the Apa-Hotamış conveyance canal which will be constructed by Directorate of Water Works of Konya, some swelling soils have been seen. The samples taken from these places have 35-95 kPa swelling pressure. To prevent the swelling pressure arising from the penetration of water to the concrete channel, it was proposed to make 10 cm concrete coating by spreading the geomembrane and geotextile between the soil and concrete. In this way, the pressure (35-95 kPa) caused by the swelling and cracking of concrete failure will be blocked.Keywords: conveyance channel, swelling pressure, geomembrane, geotextile, concrete
Procedia PDF Downloads 412