Search results for: future of CI as a cochlear delivery channel
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 10291

Search results for: future of CI as a cochlear delivery channel

10291 Cochlear Implants and the Emerging Therapies for Managing Hearing Loss

Authors: Hesham Kozou

Abstract:

Sensorineural hearing loss (SNHL) poses a significant challenge due to limited access to the inner ear for therapies. Emerging treatments such as regenerative, genetic, and pharmacotherapies offer hope for addressing this condition. This study aims to highlight the potential of cochlear implants and emerging therapies in managing sensorineural hearing loss by improving access to the inner ear. The study is conducted through a review of relevant literature and research articles in the field of cochlear implants and emerging therapies for hearing loss. It outlines how advancements in cochlear implant technologies, electrodes, and surgical techniques can facilitate the delivery of therapies to the inner ear, potentially revolutionizing the treatment of sensorineural hearing loss. The study underscores the potential of cochlear implants and emerging therapies in revolutionizing the treatment landscape for sensorineural hearing loss, emphasizing the feasibility of curing this condition by leveraging technological advancements.

Keywords: therapies for hearing loss management, future of CI as a cochlear delivery channel, regenerative, genetic and pharmacotherapeutic management of hearing loss

Procedia PDF Downloads 48
10290 Dual-Channel Multi-Band Spectral Subtraction Algorithm Dedicated to a Bilateral Cochlear Implant

Authors: Fathi Kallel, Ahmed Ben Hamida, Christian Berger-Vachon

Abstract:

In this paper, a Speech Enhancement Algorithm based on Multi-Band Spectral Subtraction (MBSS) principle is evaluated for Bilateral Cochlear Implant (BCI) users. Specifically, dual-channel noise power spectral estimation algorithm using Power Spectral Densities (PSD) and Cross Power Spectral Densities (CPSD) of the observed signals is studied. The enhanced speech signal is obtained using Dual-Channel Multi-Band Spectral Subtraction ‘DC-MBSS’ algorithm. For performance evaluation, objective speech assessment test relying on Perceptual Evaluation of Speech Quality (PESQ) score is performed to fix the optimal number of frequency bands needed in DC-MBSS algorithm. In order to evaluate the speech intelligibility, subjective listening tests are assessed with 3 deafened BCI patients. Experimental results obtained using French Lafon database corrupted by an additive babble noise at different Signal-to-Noise Ratios (SNR) showed that DC-MBSS algorithm improves speech understanding for single and multiple interfering noise sources.

Keywords: speech enhancement, spectral substracion, noise estimation, cochlear impalnt

Procedia PDF Downloads 549
10289 Minimal Incision Cochlear Implantation in Congenital Abnormality: A Case Report

Authors: Munish Saroch, Amit Saini

Abstract:

Introduction: Many children with congenital malformation of inner ear have undergone cochlear implant (CI) surgery. The results for cochlear implant surgery in these children are very encouraging and provide a ray of hope for these patients. Objective: The main objective of this presentation is to prove that even in Mondini’s deformity Minimal incision cochlear implantation improves cosmesis, reduces post-operative infection and earliest switch on of device. Methods: We report a case of two-year-old child suffering from Mondini’s deformity who underwent CI with minimal incision cochlear implantation (MICI). MICI has been developed with the aims of reducing the impact of surgery on the patient without any preoperative shaving of hairs. Results: Patient after surgery with MICI showed better looking postauricular scar, low post-operative morbidity in comparison to conventional wider access approach and hence earliest switch on of device (1st post operative day). Conclusion: We are of opinion that MICI is safe and successful in Mondini’s deformity.

Keywords: CI, Cochlear Implant, MICI, Minimal Incision Cochlear Implantation, HL, Hearing Loss, HRCT, High Resolution Computer Tomography, MRI, Magnetic resonance imaging, SCI, Standard cochlear implantation

Procedia PDF Downloads 216
10288 128-Multidetector CT for Assessment of Optimal Depth of Electrode Array Insertion in Cochlear Implant Operations

Authors: Amina Sultan, Mohamed Ghonim, Eman Oweida, Aya Abdelaziz

Abstract:

Objective: To assess the diagnostic reliability of multi-detector CT in pre and post-operative evaluation of cochlear implant candidates. Material and Methods: The study includes 40 patients (18 males and 22 females); mean age 5.6 years. They were classified into two groups: Group A (20 patients): cochlear implant device was Nucleus-22 and Group B (20 patients): the device was MED-EL. Cochlear length (CL) and cochlear height (CH) were measured pre-operatively by 128-multidetector CT. Electrode length (EL) and insertion depth angle (α) were measured post-operatively by MDCT. Results: For Group A mean CL was 9.1 mm ± 0.4 SD; mean CH was 4.1 ± 0.3 SD; mean EL was 18 ± 2.7 SD; mean α angle was 299.05 ± 37 SD. Significant statistical correlation (P < 0.05) was found between preoperative CL and post-operative EL (r²=0.6); as well as EL and α angle (r²=0.7). Group B's mean CL was 9.1 mm ± 0.3 SD; mean CH was 4.1 ± 0.4 SD; mean EL was 27 ± 2.1 SD; mean α angle was 287.6 ± 41.7 SD. Significant statistical correlation was found between CL and EL (r²= 0.6) and α angle (r²=0.5). Also, a strong correlation was found between EL and α angle (r²=0.8). Significant statistical difference was detected between the two devices as regards to the electrode length. Conclusion: Multidetector CT is a reliable tool for preoperative planning and post-operative evaluation of the outcomes of cochlear implant operations. Cochlear length is a valuable prognostic parameter for prediction of the depth of electrode array insertion which can influence criteria of device selection.

Keywords: angle of insertion (α angle), cochlear implant (CI), cochlear length (CL), Multidetector Computed Tomography (MDCT)

Procedia PDF Downloads 192
10287 Tactile Sensory Digit Feedback for Cochlear Implant Electrode Insertion

Authors: Yusuf Bulale, Mark Prince, Geoff Tansley, Peter Brett

Abstract:

Cochlear Implantation (CI) which became a routine procedure for the last decades is an electronic device that provides a sense of sound for patients who are severely and profoundly deaf. Today, cochlear implantation technology uses electrode array (EA) implanted manually into the cochlea. The optimal success of this implantation depends on the electrode technology and deep insertion techniques. However, this manual insertion procedure may cause mechanical trauma which can lead to a severe destruction of the delicate intracochlear structure. Accordingly, future improvement of the cochlear electrode implant insertion needs reduction of the excessive force application during the cochlear implantation which causes tissue damage and trauma. This study is examined tool-tissue interaction of large prototype scale digit embedded with distributive tactile sensor based upon cochlear electrode and large prototype scale cochlea phantom for simulating the human cochlear which could lead to small-scale digit requirements. The digit, distributive tactile sensors embedded with silicon-substrate was inserted into the cochlea phantom to measure any digit/phantom interaction and position of the digit in order to minimize tissue and trauma damage during the electrode cochlear insertion. The digit has provided tactile information from the digit-phantom insertion interaction such as contact status, tip penetration, obstacles, relative shape and location, contact orientation and multiple contacts. The tests demonstrated that even devices of such a relative simple design with low cost have a potential to improve cochlear implant surgery and other lumen mapping applications by providing tactile sensory feedback information and thus controlling the insertion through sensing and control of the tip of the implant during the insertion. In that approach, the surgeon could minimize the tissue damage and potential damage to the delicate structures within the cochlear caused by current manual electrode insertion of the cochlear implantation. This approach also can be applied to other minimally invasive surgery applications as well as diagnosis and path navigation procedures.

Keywords: cochlear electrode insertion, distributive tactile sensory feedback information, flexible digit, minimally invasive surgery, tool/tissue interaction

Procedia PDF Downloads 397
10286 The Effect of Whole Word Method on Mean Length of Utterance (MLU) of 3 to 6 Years Old Children with Cochlear Implant Having Normal IQ

Authors: Elnaz Dabiri, Somayeh Hamidnezhad

Abstract:

Background and Objective: This study aims at investigating the effect of whole word method on Mean Length of Utterance (MLU) of 3 to 6 years old children with cochlear implants having normal IQ. Materials and Methods: In this quasi-experimental and interventional study, 20 children with cochlear implants, aged between 3and 6 years, and normal IQ were selected from Tabriz cochlear implants center using convenience sampling. Afterward, they were randomly bifurcated. The first group was educated by whole-word reading method along with traditional methods and the second group by traditional methods. Both groups had three sessions of 45-minutes each, every week continuously for a period of 3 months. Pre-test and post-test language abilities of both groups were assessed using the TOLD test. Results: Both groups before training have the same age, IQ, and MLU, but after training the first group shows a considerable improvement in MLU in comparison with the second group. Conclusions: Reading training by the whole word method have more effect on MLU of children with cochlear implants in comparison of the traditional method.

Keywords: cochlear implants, reading training, traditional methods, language therapy, whole word method, Mean Length of Utterance (MLU)

Procedia PDF Downloads 333
10285 An Automated Sensor System for Cochlear Implants Electrode Array Insertion

Authors: Lei Hou, Xinli Du, Nikolaos Boulgouris

Abstract:

A cochlear implant, referred to as a CI, is a small electronic device that can provide direct electrical stimulation to the auditory nerve. During cochlear implant surgery, atraumatic electrode array insertion is considered to be a crucial step. However, during implantation, the mechanical behaviour of an electrode array inside the cochlea is not known. The behaviour of an electrode array inside of the cochlea is hardly identified by regular methods. In this study, a CI electrode array capacitive sensor system is proposed. It is able to automatically determine the array state as a result of the capacitance variations. Instead of applying sensors to the electrode array, the capacitance information from the electrodes will be gathered and analysed. Results reveal that this sensing method is capable of recognising different states when fed into a pre-shaped model.

Keywords: cochlear implant, electrode, hearing preservation, insertion force, capacitive sensing

Procedia PDF Downloads 238
10284 Auditory and Language Skills Development after Cochlear Implantation in Children with Multiple Disabilities

Authors: Tamer Mesallam, Medhat Yousef, Ayna Almasaad

Abstract:

BACKGROUND: Cochlear implantation (CI) in children with additional disabilities can be a fundamental and supportive intervention. Although, there may be some positive impacts of CI on children with multiple disabilities such as better outcomes of communication skills, development, and quality of life, the families of those children complain from the post-implant habilitation efforts that considered as a burden. OBJECTIVE: To investigate the outcomes of CI children with different co-disabilities through using the Meaningful Auditory Integration Scale (MAIS) and the Meaningful Use of Speech Scale (MUSS) as outcome measurement tools. METHODS: The study sample comprised 25 hearing-impaired children with co-disability who received cochlear implantation. Age and gender-matched control group of 25 cochlear-implanted children without any other disability has been also included. The participants' auditory skills and speech outcomes were assessed using MAIS and MUSS tests. RESULTS: There was a statistically significant difference in the different outcomes measure between the two groups. However, the outcomes of some multiple disabilities subgroups were comparable to the control group. Around 40% of the participants with co-disabilities experienced advancement in their methods of communication from behavior to oral mode. CONCLUSION: Cochlear-implanted children with multiple disabilities showed variable degrees of auditory and speech outcomes. The degree of benefits depends on the type of the co-disability. Long-term follow-up is recommended for those children.

Keywords: children with disabilities, Cochlear implants, hearing impairment, language development

Procedia PDF Downloads 119
10283 Healthcare in COVID-19 and It’s Impact on Children with Cochlear Implants

Authors: Amirreza Razzaghipour, Mahdi Khalili

Abstract:

References from the World Health Organization and the Center for Disease Control for deceleration the spread of the Novel COVID-19, comprises social estrangement, frequent handwashing, and covering your mouth when around others. As hearing healthcare specialists, the influence of existenceinvoluntary to boundary social interactions on persons with hearing impairment was significant for us to understand. We found ourselves delaying cochlear implant (CI) surgeries. All children, and chiefly those with hearing loss, are susceptible to reductions in spoken communication. Hearing plans, such as cochlear implants, provide children with hearing loss access to spoken communication and provision language development. when provided early and used consistently, these supplies help children with hearing loss to engage in spoken connections. Cochlear implant (CI) is a standard medical-surgical treatment for bilateral severe to profound hearing loss with no advantage with the hearing aid. Hearing is one of the most important senses in humans. Pediatric hearing loss establishes one of the most important public health challenges. Children with hearing loss are recognized early and habilitated via hearing aids or with cochlear implants (CIs). Suitable care and maintenance as well as continuous auditory verbal therapy (AVT) are also essential in reaching for the successful attainment of language acquisition. Children with hearing loss posture important challenges to their parents, particularly when there is limited admission to their hearing care providers. The disruption in the routine of their hearing and therapy follow-up services has had substantial effects on the children as well as their parents.

Keywords: healthcare, covid-19, cochlear implants, spoken communication, hearing loss

Procedia PDF Downloads 166
10282 Disease Characteristics of Neurofibromatosis Type II and Cochlear Implantation

Authors: Boxiang Zhuang

Abstract:

This study analyzes the clinical manifestations, hearing rehabilitation methods and outcomes of a complex case of neurofibromatosis type II (NF2). Methods: The clinical manifestations, medical history, clinical data, surgical methods and postoperative hearing rehabilitation outcomes of an NF2 patient were analyzed to determine the hearing reconstruction method and postoperative effect for a special type of NF2 acoustic neuroma. Results: The patient had bilateral acoustic neuromas with profound sensorineural hearing loss in both ears. Peripheral blood genetic testing did not reveal pathogenic gene mutations, suggesting mosaicism. The patient had an intracochlear schwannoma in the right ear and severely impaired vision in both eyes. Cochlear implantation with tumor retention was performed in the right ear. After 2 months of family-based auditory and speech rehabilitation, the Categories of Auditory Performance (CAP) score improved from 0 to 5. Conclusion: NF2 has complex clinical manifestations and poor prognosis. For NF2 patients with intracochlear tumors, cochlear implantation with tumor retention can be used to reconstruct hearing.

Keywords: NF2, intracochlear schwannoma, hearing reconstruction, cochlear implantation

Procedia PDF Downloads 13
10281 Influence of Auditory Visual Information in Speech Perception in Children with Normal Hearing and Cochlear Implant

Authors: Sachin, Shantanu Arya, Gunjan Mehta, Md. Shamim Ansari

Abstract:

The cross-modal influence of visual information on speech perception can be illustrated by the McGurk effect which is an illusion of hearing of syllable /ta/ when a listener listens one syllable, e.g.: /pa/ while watching a synchronized video recording of syllable, /ka/. The McGurk effect is an excellent tool to investigate multisensory integration in speech perception in both normal hearing and hearing impaired populations. As the visual cue is unaffected by noise, individuals with hearing impairment rely more than normal listeners on the visual cues.However, when non congruent visual and auditory cues are processed together, audiovisual interaction seems to occur differently in normal and persons with hearing impairment. Therefore, this study aims to observe the audiovisual interaction in speech perception in Cochlear Implant users compares the same with normal hearing children. Auditory stimuli was routed through calibrated Clinical audiometer in sound field condition, and visual stimuli were presented on laptop screen placed at a distance of 1m at 0 degree azimuth. Out of 4 presentations, if 3 responses were a fusion, then McGurk effect was considered to be present. The congruent audiovisual stimuli /pa/ /pa/ and /ka/ /ka/ were perceived correctly as ‘‘pa’’ and ‘‘ka,’’ respectively by both the groups. For the non- congruent stimuli /da/ /pa/, 23 children out of 35 with normal hearing and 9 children out of 35 with cochlear implant had a fusion of sounds i.e. McGurk effect was present. For the non-congruent stimulus /pa/ /ka/, 25 children out of 35 with normal hearing and 8 children out of 35 with cochlear implant had fusion of sounds.The children who used cochlear implants for less than three years did not exhibit fusion of sound i.e. McGurk effect was absent in this group of children. To conclude, the results demonstrate that consistent fusion of visual with auditory information for speech perception is shaped by experience with bimodal spoken language during early life. When auditory experience with speech is mediated by cochlear implant, the likelihood of acquiring bimodal fusion is increased and it greatly depends on the age of implantation. All the above results strongly support the need for screening children for hearing capabilities and providing cochlear implants and aural rehabilitation as early as possible.

Keywords: cochlear implant, congruent stimuli, mcgurk effect, non-congruent stimuli

Procedia PDF Downloads 308
10280 Developing Biocompatible Iridium Oxide Electrodes for Bone-Guided Extra-Cochlear Implant

Authors: Yung-Shan Lu, Chia-Fone Lee, Shang-Hsuan Li, Chien-Hao Liu

Abstract:

Recently, various bioelectronic devices have been developed for neurologic disease treatments via electro-stimulations such as cochlear implants and retinal prosthesis. Since the electric signal needs electrodes to be transmitted to an organism, electrodes play an important role of stimulations. The materials of stimulation electrodes affect the efficiency of the delivered currents. The higher the efficiency of the electrodes, the lower the threshold current can be used to stimulate the organism which minimizes the potential damages to the adjacent tissues. In this study, we proposed a biocompatible composite electrode composed of high-charge-capacity iridium oxide (IrOₓ) film for a bone-guide extra-cochlear implant. IrOₓ was exploited to decrease the threshold current due to its high capacitance and low impedance. The IrOₓ electrode was fabricated via microelectromechanical systems (MEMS) photolithography and examined with in-vivo tests with guinea pigs. Based on the measured responses of brain waves to sound, the results demonstrated that IrOₓ electrodes have a lower threshold current compared with the Platinum (Pt) electrodes. The research results are expected to be beneficial for implantable and biocompatible electrodes for electrical stimulations.

Keywords: cochlear implants, electrode, electrical stimulation, iridium oxide

Procedia PDF Downloads 189
10279 Delivery Service and Online-and-Offline Purchasing for Collaborative Recommendations on Retail Cross-Channels

Authors: S. H. Liao, J. M. Huang

Abstract:

The delivery service business model is the final link in logistics for both online-and-offline businesses. The online-and-offline business model focuses on the entire customer purchasing process online and offline, placing greater emphasis on the importance of data to optimize overall retail operations. For the retail industry, it is an important task of information and management to strengthen the collection and investigation of consumers' online and offline purchasing data to better understand customers and then recommend products. This study implements two-stage data mining analytics for clustering and association rules analysis to investigate Taiwanese consumers' (n=2,209) preferences for delivery service. This process clarifies online-and-offline purchasing behaviors and preferences to find knowledge profiles/patterns/rules for cross-channel collaborative recommendations. Finally, theoretical and practical implications for methodology and enterprise are presented.

Keywords: delivery service, online-and-offline purchasing, retail cross-channel, collaborative recommendations, data mining analytics

Procedia PDF Downloads 31
10278 Magnetic Resonance Imaging in Cochlear Implant Patients without Magnet Removal: A Safe and Effective Workflow Management Program

Authors: Yunhe Chen, Xinyun Liu, Qian Wang, Jianan Li

Abstract:

Background Cochlear implants (CIs) are currently the primary effective treatment for severe or profound sensorineural hearing loss. As China's population ages and the number of young children rises, the demand for MRI for CI patients is expected to increase. Methods Reviewed MRI cases of 25 CI patients between 2015 and 2024, assessed imaging auditory outcomes and adverse reactions. Use the adverse event record sheet and accompanying medication sheet to record follow-up measures. Results Most CI patients undergoing MRI may face risks such as artifacts, pain, redness, swelling, tissue damage, bleeding, and magnet displacement or demagnetization. Twenty-five CI patients in our hospital were reviewed. Seven patient underwent 3.0 T MR, the others underwent 1.5 T MR. The manufacturers are 18 cases in Austria, 5 cases in Australia and 2 cases in Nurotron. Among them, one patient with bilateral CI underwent 1.5 T MR examination after head pressure bandaging, and the left magnet was displaced (CI24RE Series, Australia). This patient underwent surgical replacement of the magnet under general anesthesia. Six days after the operation, the patient's feedback indicated that the performance of the cochlear implant was consistent with the previous results following the reactivation of the external device. Based on the experience of our hospital, we proposed the feasible management scheme of MRI examination procedure for CI patients. This plan should include a module for confirming MRI imaging parameters, informed consent, educational materials for patients, and other safety measures to ensure that patients receive imaging results safely and effectively, implify clinical. Conclusion As indications for both MRI and cochlear implantation expand,the number of MRI studies recommended for patients with cochlear implants will also increase. The process and management scheme proposed in this study can help to obtain imaging results safely and effectively, and reduce clinical stress.

Keywords: cochlear implantation, MRI, magnet, displacement

Procedia PDF Downloads 12
10277 A 10-Year In-Depth Follow-up of Post-lingual Hearing Loss Patients with Chinese Domestic Cochlear Implants

Authors: Jianan Li, Lusen Shi, Haiqiao Du, Wei Chen, Qian Wang, Shuoshuo Kang, Shiming Yang

Abstract:

Background: Follow-up of cochlear implant effectiveness is mainly focused on 3 years postoperatively, and studies with more than 5 years of observation are rare, especially for local Chinese brands. Objectives: Nurotron (Chinese domestic cochlear implant brand) CI recipients who participated in the clinical trial in 2009 were followed-up for 10 years prospectively, providing data to guide doctors and patients. Material and Methods: From December 2009 to April 2010, 57 subjects underwent Nurotron Venus CI surgery at multiple centers and were continued to be followed up and assessed at 1, 2, 3, 4, 5, and 10 years after switching on. Results: All recipients were successfully implanted with CIs with no difficulty in subsequent use, with one reported case of re-implantation 9 years after implantation. The aided hearing thresholds were significantly improved one month after switching on (p<0.0001) and remained stable afterward for 10 years. Speech recognition scores were significantly higher than pre-operative results (p<0.05) and continued to improve till 3 years after switching on. At 10 years of post-operation, most subjects had improved QOL scores in most sub-items. Conclusions and Significance: Nurotron Venus CI System provides long-term, stable results in hearing speech assistance capabilities and can improve the quality of life of CI recipients.

Keywords: cochlear implantation, hearing loss, post lingual, follow up

Procedia PDF Downloads 15
10276 Opportunities and Challenges of Omni Channel Retailing in the Emerging Market

Authors: Salma Ahmed, Anil Kumar

Abstract:

This paper develops and estimates a model for understanding the drivers and barriers for Omni-Channel retail. This study serves as one of the first attempt to empirically test the effect of various factors on Omni-channel retail. Omni-channel is relative new and evolving, we hypothesize three drivers: (1) Innovative sales and marketing opportunities, (2) channel migration, (3) Cross channel synergies; and three barriers: (1) Integrated sales and marketing operations, (2) Visibility and synchronization (3) Integration and Technology challenges. The findings from the study strongly support that Omni-channel effects exist between cross channel synergy and channel migration. However, it partially supports innovative sales and marketing operations. We also found the variables which we identified as barriers to Omni-channel retail have a strong impact on Omni-channel retail.

Keywords: retailing, multichannel, Omni-channel, emerging market

Procedia PDF Downloads 548
10275 Formulation and Evaluation of Ethosomes of Plumeria indica Linn. Flowers

Authors: Sumeet Dwivedi, Shweta Shriwas, Raghvendra Dubey

Abstract:

The number of products based on new drug delivery systems has significantly increased in the past few years, and this growth is expected to continue in the near future. These biopharmaceuticals present challenges to drug delivery scientists because of their unique nature and difficulty in delivery through conventional routes. Therefore, future research will focus on the delivery of these complex molecules through different routes, including oral, nasal, pulmonary, vaginal, rectal, etc. The aim of present study was to formulate and evaluate ethosomes of Plumeria indica flowers which may deliver the drug to targeted site more efficiently than marketed preparation and also overcome the problems related with oral administration of drug. The formulations were prepared with ethanol, lecithin, propylene glycol and were evaluated.

Keywords: ethosomes, herbal extract, plumeria alba, lecithin

Procedia PDF Downloads 262
10274 Recent Trends in Supply Chain Delivery Models

Authors: Alfred L. Guiffrida

Abstract:

A review of the literature on supply chain delivery models which use delivery windows to measure delivery performance is presented. The review herein serves to meet the following objectives: (i) provide a synthesis of previously published literature on supply chain delivery performance models, (ii) provide in one paper a consolidation of research that can serve as a single source to keep researchers up to date with the research developments in supply chain delivery models, and (iii) identify gaps in the modeling of supply chain delivery performance which could stimulate new research agendas.

Keywords: delivery performance, delivery window, supply chain delivery models, supply chain performance

Procedia PDF Downloads 421
10273 Complications and Outcomes of Cochlear Implantation in Children Younger than 12 Months: A Multicenter Study

Authors: Alimohamad Asghari, Ahmad Daneshi, Mohammad Farhadi, Arash Bayat, Mohammad Ajalloueyan, Marjan Mirsalehi, Mohsen Rajati, Seyed Basir Hashemi, Nader Saki, Ali Omidvari

Abstract:

Evidence suggests that Cochlear Implantation (CI) is a beneficial approach for auditory and speech skills improvement in children with severe to profound hearing loss. However, it remains controversial if implantation in children <12 months is safe and effective compared to older children. The present study aimed to determine whether children's ages affect surgical complications and auditory and speech development. The current multicenter study enrolled 86 children who underwent CI surgery at <12 months of age (group A) and 362 children who underwent implantation between 12 and 24 months of age (group B). The Categories of Auditory Performance (CAP) and Speech Intelligibility Rating (SIR) scores were determined pre-impanation, and "one-year" and "two-year" post-implantation. Four complications (overall rate: 4.65%; three minor) occurred in group A and 12 complications (overall rate: 4.41%; nine minor) occurred in group B. We found no statistically significant difference in the complication rates between the groups (p>0.05). The mean SIR and CAP scores improved over time following CI activation in both groups. However, we did not find significant differences in CAP and SIR scores between the groups across different time points. Cochlear implantation is a safe and efficient procedure in children younger than 12 months, providing substantial auditory and speech benefits comparable to children undergoing implantation at 12 to 24 months of age. Furthermore, surgical complications in younger children are similar to those of children undergoing the CI at an older age.

Keywords: cochlear implant, Infant, complications, outcome

Procedia PDF Downloads 108
10272 Numerical Simulation of Production of Microspheres from Polymer Emulsion in Microfluidic Device toward Using in Drug Delivery Systems

Authors: Nizar Jawad Hadi, Sajad Abd Alabbas

Abstract:

Because of their ability to encapsulate and release drugs in a controlled manner, microspheres fabricated from polymer emulsions using microfluidic devices have shown promise for drug delivery applications. In this study, the effects of velocity, density, viscosity, and surface tension, as well as channel diameter, on microsphere generation were investigated using Fluent Ansys software. The software was programmed with the physical properties of the polymer emulsion such as density, viscosity and surface tension. Simulation will then be performed to predict fluid flow and microsphere production and improve the design of drug delivery applications based on changes in these parameters. The effects of capillary and Weber numbers are also studied. The results of the study showed that the size of the microspheres can be controlled by adjusting the speed and diameter of the channel. Narrower microspheres resulted from narrower channel widths and higher flow rates, which could improve drug delivery efficiency, while smaller microspheres resulted from lower interfacial surface tension. The viscosity and density of the polymer emulsion significantly affected the size of the microspheres, ith higher viscosities and densities producing smaller microspheres. The loading and drug release properties of the microspheres created with the microfluidic technique were also predicted. The results showed that the microspheres can efficiently encapsulate drugs and release them in a controlled manner over a period of time. This is due to the high surface area to volume ratio of the microspheres, which allows for efficient drug diffusion. The ability to tune the manufacturing process using factors such as speed, density, viscosity, channel diameter, and surface tension offers a potential opportunity to design drug delivery systems with greater efficiency and fewer side effects.

Keywords: polymer emulsion, microspheres, numerical simulation, microfluidic device

Procedia PDF Downloads 64
10271 A Dissipative Particle Dynamics Study of a Capsule in Microfluidic Intracellular Delivery System

Authors: Nishanthi N. S., Srikanth Vedantam

Abstract:

Intracellular delivery of materials has always proved to be a challenge in research and therapeutic applications. Usually, vector-based methods, such as liposomes and polymeric materials, and physical methods, such as electroporation and sonoporation have been used for introducing nucleic acids or proteins. Reliance on exogenous materials, toxicity, off-target effects was the short-comings of these methods. Microinjection was an alternative process which addressed the above drawbacks. However, its low throughput had hindered its adoption widely. Mechanical deformation of cells by squeezing them through constriction channel can cause the temporary development of pores that would facilitate non-targeted diffusion of materials. Advantages of this method include high efficiency in intracellular delivery, a wide choice of materials, improved viability and high throughput. This cell squeezing process can be studied deeper by employing simple models and efficient computational procedures. In our current work, we present a finite sized dissipative particle dynamics (FDPD) model to simulate the dynamics of the cell flowing through a constricted channel. The cell is modeled as a capsule with FDPD particles connected through a spring network to represent the membrane. The total energy of the capsule is associated with linear and radial springs in addition to constraint of the fixed area. By performing detailed simulations, we studied the strain on the membrane of the capsule for channels with varying constriction heights. The strain on the capsule membrane was found to be similar though the constriction heights vary. When strain on the membrane was correlated to the development of pores, we found higher porosity in capsule flowing in wider channel. This is due to localization of strain to a smaller region in the narrow constriction channel. But the residence time of the capsule increased as the channel constriction narrowed indicating that strain for an increased time will cause less cell viability.

Keywords: capsule, cell squeezing, dissipative particle dynamics, intracellular delivery, microfluidics, numerical simulations

Procedia PDF Downloads 140
10270 Analysis of Joint Source Channel LDPC Coding for Correlated Sources Transmission over Noisy Channels

Authors: Marwa Ben Abdessalem, Amin Zribi, Ammar Bouallègue

Abstract:

In this paper, a Joint Source Channel coding scheme based on LDPC codes is investigated. We consider two concatenated LDPC codes, one allows to compress a correlated source and the second to protect it against channel degradations. The original information can be reconstructed at the receiver by a joint decoder, where the source decoder and the channel decoder run in parallel by transferring extrinsic information. We investigate the performance of the JSC LDPC code in terms of Bit-Error Rate (BER) in the case of transmission over an Additive White Gaussian Noise (AWGN) channel, and for different source and channel rate parameters. We emphasize how JSC LDPC presents a performance tradeoff depending on the channel state and on the source correlation. We show that, the JSC LDPC is an efficient solution for a relatively low Signal-to-Noise Ratio (SNR) channel, especially with highly correlated sources. Finally, a source-channel rate optimization has to be applied to guarantee the best JSC LDPC system performance for a given channel.

Keywords: AWGN channel, belief propagation, joint source channel coding, LDPC codes

Procedia PDF Downloads 357
10269 Algorithm and Software Based on Multilayer Perceptron Neural Networks for Estimating Channel Use in the Spectral Decision Stage in Cognitive Radio Networks

Authors: Danilo López, Johana Hernández, Edwin Rivas

Abstract:

The use of the Multilayer Perceptron Neural Networks (MLPNN) technique is presented to estimate the future state of use of a licensed channel by primary users (PUs); this will be useful at the spectral decision stage in cognitive radio networks (CRN) to determine approximately in which time instants of future may secondary users (SUs) opportunistically use the spectral bandwidth to send data through the primary wireless network. To validate the results, sequences of occupancy data of channel were generated by simulation. The results show that the prediction percentage is greater than 60% in some of the tests carried out.

Keywords: cognitive radio, neural network, prediction, primary user

Procedia PDF Downloads 371
10268 Low Overhead Dynamic Channel Selection with Cluster-Based Spatial-Temporal Station Reporting in Wireless Networks

Authors: Zeyad Abdelmageid, Xianbin Wang

Abstract:

Choosing the operational channel for a WLAN access point (AP) in WLAN networks has been a static channel assignment process initiated by the user during the deployment process of the AP, which fails to cope with the dynamic conditions of the assigned channel at the station side afterward. However, the dramatically growing number of Wi-Fi APs and stations operating in the unlicensed band has led to dynamic, distributed, and often severe interference. This highlights the urgent need for the AP to dynamically select the best overall channel of operation for the basic service set (BSS) by considering the distributed and changing channel conditions at all stations. Consequently, dynamic channel selection algorithms which consider feedback from the station side have been developed. Despite the significant performance improvement, existing channel selection algorithms suffer from very high feedback overhead. Feedback latency from the STAs, due to the high overhead, can cause the eventually selected channel to no longer be optimal for operation due to the dynamic sharing nature of the unlicensed band. This has inspired us to develop our own dynamic channel selection algorithm with reduced overhead through the proposed low-overhead, cluster-based station reporting mechanism. The main idea behind the cluster-based station reporting is the observation that STAs which are very close to each other tend to have very similar channel conditions. Instead of requesting each STA to report on every candidate channel while causing high overhead, the AP divides STAs into clusters then assigns each STA in each cluster one channel to report feedback on. With the proper design of the cluster based reporting, the AP does not lose any information about the channel conditions at the station side while reducing feedback overhead. The simulation results show equal performance and, at times, better performance with a fraction of the overhead. We believe that this algorithm has great potential in designing future dynamic channel selection algorithms with low overhead.

Keywords: channel assignment, Wi-Fi networks, clustering, DBSCAN, overhead

Procedia PDF Downloads 118
10267 Unequal Error Protection of VQ Image Transmission System

Authors: Khelifi Mustapha, A. Moulay lakhdar, I. Elawady

Abstract:

We will study the unequal error protection for VQ image. We have used the Reed Solomon (RS) Codes as Channel coding because they offer better performance in terms of channel error correction over a binary output channel. One such channel (binary input and output) should be considered if it is the case of the application layer, because it includes all the features of the layers located below and on the what it is usually not feasible to make changes.

Keywords: vector quantization, channel error correction, Reed-Solomon channel coding, application

Procedia PDF Downloads 365
10266 The Implication of Augmentation Cystoplasty with Mitrofanoff Channel on Reproduction Age Group and Outcome of Pregnancy

Authors: Amal A. Qedrah, Sofia A. Malik, Madiha Akbar

Abstract:

The aim of this article is to share a rare clinical case of pregnancy and surgical delivery in a patient who has undergone augmentation cystoplasty with mitrofanoff channel in the past. Methods: This case report is about a woman who conceived naturally at the age of 27, previously underwent augmentation cystoplasty at the age of 10 years with mitrofanoff procedure using self-clean intermittent catheterization. Furthermore, this pregnancy was complicated by the presence of preeclampsia diagnosed at term and PROM. Following the failure of induction for intrapartum preeclampsia, the patient delivered a healthy baby via low transverse cesarean section at 38 weeks done at Latifa Hospital, Dubai. Conclusion: The procedure is done at a pediatric or young age, after which most patients reach reproductive age. There is no contraindication to pregnancy vaginally or surgically; however, this case was complicated by preeclampsia, due to which this patient was taken for a cesarean section. It is advisable to consult a urologist frequently along with taking regular bacteriological urine samples and blood samples with renal ultrasonography for the evaluation of the kidney. Antibacterial treatment or prophylaxis should be used during pregnancy if necessary and intermittent self-catherization is mostly performed routinely. It is also important to have a urologist on standby during the surgery in order to avoid and/or fix any complications that might come forth.

Keywords: augmentation cystoplasty, cesarean section, delivery, mitrofanoff channel

Procedia PDF Downloads 160
10265 Numerical Simulation of Effect of Various Rib Configurations on Enhancing Heat Transfer of Matrix Cooling Channel

Authors: Seok Min Choi, Minho Bang, Seuong Yun Kim, Hyungmin Lee, Won-Gu Joo, Hyung Hee Cho

Abstract:

The matrix cooling channel was used for gas turbine blade cooling passage. The matrix cooling structure is useful for the structure stability however the cooling performance of internal cooling channel was not enough for cooling. Therefore, we designed the rib configurations in the matrix cooling channel to enhance the cooling performance. The numerical simulation was conducted to analyze cooling performance of rib configured matrix cooling channel. Three different rib configurations were used which are vertical rib, angled rib and c-type rib. Three configurations were adopted in two positions of matrix cooling channel which is one fourth and three fourth of channel. The result shows that downstream rib has much higher cooling performance than upstream rib. Furthermore, the angled rib in the channel has much higher cooling performance than vertical rib. This is because; the angled rib improves the swirl effect of matrix cooling channel more effectively. The friction factor was increased with the installation of rib. However, the thermal performance was increased with the installation of rib in the matrix cooling channel.

Keywords: matrix cooling, rib, heat transfer, gas turbine

Procedia PDF Downloads 460
10264 Three-Dimensional Measurement and Analysis of Facial Nerve Recess

Authors: Kang Shuo-Shuo, Li Jian-Nan, Yang Shiming

Abstract:

Purpose: The three-dimensional anatomical structure of the facial nerve recess and its relationship were measured by high-resolution temporal bone CT to provide imaging reference for cochlear implant operation. Materials and Methods: By analyzing the high-resolution CT of 160 cases (320 pleural ears) of the temporal bone, the following parameters were measured at the axial window niche level: 1. The distance between the facial nerve and chordae tympani nerve d1; 2. Distance between the facial nerve and circular window niche d2; 3. The relative Angle between the facial nerve and the circular window niche a; 4. Distance between the middle point of the face recess and the circular window niche d3; 5. The relative angle between the middle point of the face recess and the circular window niche b. Factors that might influence the anatomy of the facial recess were recorded, including the patient's sex, age, and anatomical variation (e.g., vestibular duct dilation, mastoid gas type, mothoid sinus advancement, jugular bulbar elevation, etc.), and the correlation between these factors and the measured facial recess parameters was analyzed. Result: The mean value of face-drum distance d1 is (3.92 ± 0.26) mm, the mean value of face-niche distance d2 is (5.95 ± 0.62) mm, the mean value of face-niche Angle a is (94.61 ± 9.04) °, and the mean value of fossa - niche distance d3 is (6.46 ± 0.63) mm. The average fossa-niche Angle b was (113.47 ± 7.83) °. Gender, age, and anterior sigmoid sinus were the three factors affecting the width of the opposite recess d1, the Angle of the opposite nerve relative to the circular window niche a, and the Angle of the facial recess relative to the circular window niche b. Conclusion: High-resolution temporal bone CT before cochlear implantation can show the important anatomical relationship of the facial nerve recess, and the measurement results have clinical reference value for the operation of cochlear implantation.

Keywords: cochlear implantation, recess of facial nerve, temporal bone CT, three-dimensional measurement

Procedia PDF Downloads 16
10263 Implementing Delivery Drones in Logistics Business Process: Case of Pharmaceutical Industry

Authors: Nikola Vlahovic, Blazenka Knezevic, Petra Batalic

Abstract:

In this paper, we will present a research about feasibility of implementing unmanned aerial vehicles, also known as 'drones', in logistics. Research is based on available information about current incentives and experiments in application of delivery drones in commercial use. Overview of current pilot projects and literature, as well as an overview of detected challenges, will be compiled and presented. Based on these findings, we will present a conceptual model of business process that implements delivery drones in business to business logistic operations. Business scenario is based on a pharmaceutical supply chain. Simulation modeling will be used to create models for running experiments and collecting performance data. Comparative study of the presented conceptual model will be given. The work will outline the main advantages and disadvantages of implementing unmanned aerial vehicles in delivery services as a supplementary distribution channel along the supply chain.

Keywords: business process, delivery drones, logistics, simulation modelling, unmanned aerial vehicles

Procedia PDF Downloads 394
10262 GE as a Channel Material in P-Type MOSFETs

Authors: S. Slimani, B. Djellouli

Abstract:

Novel materials and innovative device structures has become necessary for the future of CMOS. High mobility materials like Ge is a very promising material due to its high mobility and is being considered to replace Si in the channel to achieve higher drive currents and switching speeds .Various approaches to circumvent the scaling limits to benchmark the performance of nanoscale MOSFETS with different channel materials, the optimized structure is simulated within nextnano in order to highlight the quantum effects on DG MOSFETs when Si is replaced by Ge and SiO2 is replaced by ZrO2 and HfO2as the gate dielectric. The results have shown that Ge MOSFET have the highest mobility and high permittivity oxides serve to maintain high drive current. The simulations show significant improvements compared with DGMOSFET using SiO2 gate dielectric and Si channel.

Keywords: high mobility, high-k, quantum effects, SOI-DGMOSFET

Procedia PDF Downloads 367