Search results for: phantom limb
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 370

Search results for: phantom limb

220 The Use of STIMULAN Resorbable Antibiotic Beads in Conjunction with Autologous Tissue Transfer to Treat Recalcitrant Infections and Osteomyelitis in Diabetic Foot Wounds

Authors: Hayden R Schott, John M Felder III

Abstract:

Introduction: Chronic lower extremity wounds in the diabetic and vasculopathic populations are associated with a high degree of morbidity.When wounds require more extensive treatment than can be offered by wound care centers, more aggressive solutions involve local tissue transfer and microsurgical free tissue transfer for achieving definitive soft tissue coverage. These procedures of autologous tissue transfer (ATT) offer resilient, soft tissue coverage of limb-threatening wounds and confer promising limb salvage rates. However, chronic osteomyelitis and recalcitrant soft tissue infections are common in severe diabetic foot wounds and serve to significantly complicate ATT procedures. Stimulan is a resorbable calcium sulfate antibiotic carrier. The use of stimulan antibiotic beads to treat chronic osteomyelitis is well established in the orthopedic and plastic surgery literature. In these procedures, the beads are placed beneath the skin flap to directly deliver antibiotics to the infection site. The purpose of this study was to quantify the success of Stimulan antibiotic beads in treating recalcitrant infections in patients with diabetic foot wounds receiving ATT. Methods: A retrospective review of clinical and demographic information was performed on patients who underwent ATT with the placement of Stimulan antibiotic beads for attempted limb salvage from 2018-21. Patients were analyzed for preoperative wound characteristics, demographics, infection recurrence, and adverse outcomes as a result of product use. The primary endpoint was 90 day infection recurrence, with secondary endpoints including 90 day complications. Outcomes were compared using basic statistics and Fisher’s exact tests. Results: In this time span, 14 patients were identified. At the time of surgery, all patients exhibited clinical signs of active infection, including positive cultures and erythema. 57% of patients (n=8) exhibited chronic osteomyelitis prior to surgery, and 71% (n=10) had exposed bone at the wound base. In 57% of patients (n=8), Stimulan beads were placed beneath a free tissue flap and beneath a pedicle tissue flap in 42% of patients (n=6). In all patients, Stimulan beads were only applied once. Recurrent infections were observed in 28% of patients (n=4) at 90 days post-op, and flap nonadherence was observed in 7% (n=1). These were the only Stimulan related complications observed. Ultimately, lower limb salvage was successful in 85% of patients (n=12). Notably, there was no significant association between the preoperative presence of osteomyelitis and recurrent infections. Conclusions: The use of Stimulanantiobiotic beads to treat recalcitrant infections in patients receiving definitive skin coverage of diabetic foot wounds does not appear to demonstrate unnecessary risk. Furthermore, the lack of significance between the preoperative presence of osteomyelitis and recurrent infections indicates the successful use of Stimulan to dampen infection in patients with osteomyelitis, as is consistent with the literature. Further research is needed to identify Stimulan as the significant contributor to infection treatment using future cohort and case control studies with more patients. Nonetheless, the use of Stimulan antibiotic beads in patients with diabetic foot wounds demonstrates successful infection suppression and maintenance of definitive soft tissue coverage.

Keywords: wound care, stimulan antibiotic beads, free tissue transfer, plastic surgery, wound, infection

Procedia PDF Downloads 59
219 Parsonage Turner Syndrome PTS, Case Report

Authors: A. M. Bumbea, A. Musetescu, P. Ciurea, A. Bighea

Abstract:

Objectives: The authors present a Parsonage Turner syndrome, a rare disease characterized by onset in apparently healthy person with shoulder and/or arm pain, sensory deficit, motor deficit. The causes are not established, could be determinate by vaccination, postoperative, immunologic disease, post traumatic etc. Methods: The authors present a woman case, 32 years old, (in 2006), no medical history, with arm pain and no other symptom. The onset was sudden with pain at very high level quantified as 10 to a 0 to 10 scale, with no response to classical analgesic and corticoids. The only drugs which can reduce the intensity of pain were oxycodone hydrochloride, 60 mg daily and pregabalinum150 mg daily. After two weeks the intensity of pain was reduced to 5. The patient started a rehabilitation program. After 6 weeks the patient associated sensory and motor deficit. We performed electromyography for upper limb that showed incomplete denervation with reduced neural transmission speed. The patient receives neurotrophic drugs and painkillers for a long period and physical and kinetic therapy. After 6 months the pain was reduced to level 2 and the patient maintained only 150 mg pregabalinum for another 6 months. Then, the evaluation showed no pain but general amiotrophy in upper limb. Results: At the evaluation in 2009, the patient developed a rheumatoid syndrome with tender and swelling joints, but no positive inflammation test, no antibodies or rheumatoid factor. After two years, in 2011 the patient develops an increase of antinuclear antibodies. This context certifies the diagnosis of lupus and the patient receives the specific therapy. Conclusions: This case is not a typical case of onset of lupus with PTS, but the onset of PTS could include the onset of an immune disease.

Keywords: lupus, arm pain, patient, swelling

Procedia PDF Downloads 295
218 A Multidisciplinary Team Approach for Limb Salvage in a Rare Case of Pyoderma Gangrenosum in a Significant Circumferential Lower Extremity Wound Complicated by Diabetes and End-stage Renal Disease

Authors: Jenee Gooden, Kevin Vasquez-monterroso, Lady Paula Dejesus, Sandra Wainwright, Daniel Kim, Mackenzie Walker

Abstract:

Introduction: Pyoderma gangrenosum (PG) is a rare, rapidly progressive, neutrophilic ulcerative colitis condition with an incidence of 3 to 10 cases per year ¹ ². Due to the similar appearance, PG is often misdiagnosed as a diabetic ulcer in diabetic patients. Though they may clinically appear similar in appearance, the treatment protocol and diagnostic criteria differ. Also, end-stage renal disease (ESRD) is often a condition seen in diabetic patients, which can have a significant impact on wound healing due to the wide range of uremic toxins³. This case study demonstrates a multidisciplinary team and multimodal treatment approach by podiatric surgery, general surgery, rheumatology, infectious disease, interventional cardiology, wound care and hyperbaric medicine for an uncontrolled diabetic with pyoderma gangrenosum of a significant circumferential wound, covering almost the entire right lower extremity. Methods:56 y.o male presents with multiple PG ulcerations, including the chest, right posterior lower extremity and sacrum. All ulcerations were previously managed by the same wound care specialist. His chief complaint was worsening PG ulcerations accompanied by a fever of 103 °F . This case study focuses on the wound to his RLE. Past medical history significant for diabetes mellitus type 2 with hemoglobin A1c of 10% and end stage renal disease (ESRD) on hemodialysis. A multidisciplinary team approach by podiatric surgery, general surgery, rheumatology, infectious disease, interventional cardiology, wound care and hyperbaric medicine was successfully used to perform right lower extremity limb salvage. The patient was managed by rheumatology for the continuation of prior medication, as well as the mutual agreement with wound care for the addition of dapsone. A coronary CT angiogram was performed by interventional cardiology, but no significant disease was noted, and no further vascular workup was necessary. Multiple surgical sharp wide excisional debridements with application of allografts and split thickness skin grafts for the circumferential ulceration that encompassed almost the entire right lower extremity were performed by both podiatric surgery and general surgery. Wound cultures and soft tissue biopsies were performed, and infectious disease managed antibiotic therapy. Hyperbaric oxygen therapy and wound vac therapy by wound care were also completed as adjunct management. Results: Prevention of leg amputation by limb salvage of the RLE was accomplished by a multidisciplinary team approach, with the wound size decreasing over a total of 29 weeks from 600 cm² to 12.0 x 3.5 x 0.2 cm. Our multidisciplinary team included podiatric surgery, general surgery, rheumatology, infectious disease, interventional cardiology, wound care and hyperbaric medicine. Discussion: Wound healing, in general, can have its challenges, and those challenges are only magnified when accompanied by multiple systemic illnesses. Though the negative impact of diabetes on wound healing is well known, the compound impact of being a diabetic with ESRD and having pyoderma gangrenosum is not. This case demonstrates the necessity for a multidisciplinary team approach with a wide array of treatment modalities to optimize wound healing and perform limb salvage with prevention of lower extremity amputation.

Keywords: diabetes, podiatry, pyoderma gangrenosum, end stage renal disease

Procedia PDF Downloads 41
217 Negative Pressure Wound Therapy in Complex Injuries of the Limbs

Authors: Mihail Nagea, Olivera Lupescu, Nicolae Ciurea, Alexandru Dimitriu, Alina Grosu

Abstract:

Introduction: As severe open injuries are more and more frequent in modern traumatology, threatening not only the integrity of the affected limb but even the life of the patients, new methods desired to cope with the consequences of these traumas were described. Vacuum therapy is one such method which has been described as enhancing healing in trauma with extensive soft-tissue injuries, included those with septic complications. Material and methods: Authors prospectively analyze 15 patients with severe lower limb trauma with MESS less than 6, with considerable soft tissue loss following initial debridement and fracture fixation. The patients needed serial debridements and vacuum therapy was applied after delayed healing due to initial severity of the trauma, for an average period of 12 days (7 - 23 days).In 7 cases vacuum therapy was applied for septic complications. Results: Within the study group, there were no local complications; secondary debridements were performed for all the patients and vacuum system was re-installed after these debridements. No amputations were needed. Medical records were reviewed in order to compare the outcome of the patients: the hospital stay, anti-microbial therapy, time to healing of the bone and soft tissues (there is no standard group to be compared with) and the result showed considerable improvements in the outcome of the patients. Conclusion: Vacuum therapy improves healing of the soft tissues, including those infected; hospital stay and the number of secondary necessary procedures are reduced. Therefore it is considered a valuable support in treating trauma of the limbs with severe soft tissue injuries.

Keywords: complex injuries, negative pressure, open fractures, wound therapy

Procedia PDF Downloads 273
216 Clinical Parameters Response to Low Level Laser Versus Monochromatic Near Infrared Photo Energy in Diabetic Patient with Peripheral Neuropathy

Authors: Abeer Ahmed Abdehameed

Abstract:

Background: Diabetic sensorimotor polyneuropathy (DSP) is one of the most common micro vascular complications of type 2 diabetes. Loss of sensation is thought to contribute to lake of static and dynamic stability and increased risk of falling. Purpose: The purpose of this study was to compare the effects of low level laser (LLL) and monochromatic near infrared photo energy (MIRE) on pain , cutaneous sensation, static stability and index of lower limb blood flow in diabetic with peripheral neuropathy. Methods: Forty subjects with diabetic peripheral neuropathy were recruited for study. They were divided into two groups: The ( MIRE) group that included (20) patients and (LLL) group included (20) patients. All patients in the study had been subjected to various physical assessment procedures including pain, cutaneous sensation, Doppler flow meter and static stability assessments. The baseline measurements were followed by treatment sessions that conducted twice a week for 6 successive weeks. Results: The statistical analysis of the data had revealed significant improvement of the pain in both groups, with significant improvement in cutaneous sensation and static balance in (MIRE) group compared to (LLL) group; on the other hand results showed no significant differences on lower limb blood flow in both groups. Conclusion: Low level laser and monochromatic near infrared therapy can improve painful symptoms in patients with diabetic neuropathy. On the other hand (MIRE) is useful in improving cutaneous sensation and static stability in patients with diabetic neuropathy.

Keywords: diabetic neuropathy, doppler flow meter, low level laser, monochromatic near infrared photo energy

Procedia PDF Downloads 287
215 Effect of Two Types of Shoe Insole on the Dynamics of Lower Extremities Joints in Individuals with Leg Length Discrepancy during Stance Phase of Walking

Authors: Mansour Eslami, Fereshte Habibi

Abstract:

Limb length discrepancy (LLD), or anisomeric, is defined as a condition in which paired limbs are noticeably unequal. Individuals with LLD during walking use compensatory mechanisms to dynamically lengthen the short limb and shorten the long limb to minimize the displacement of the body center of mass and consequently reduce body energy expenditure. Due to the compensatory movements created, LLD greater than 1 cm increases the odds of creating lumbar problems and hip and knee osteoarthritis. Insoles are non-surgical therapies that are recommended to improve the walking pattern, pain and create greater symmetry between the two lower limbs. However, it is not yet clear what effect insoles have on the variables related to injuries during walking. The aim of the present study was to evaluate the effect of internal and external heel lift insoles on pelvic kinematic in sagittal and frontal planes and lower extremity joint moments in individuals with mild leg length discrepancy during the stance phase of walking. Biomechanical data of twenty-eight men with structural leg length discrepancy of 10-25 mm were collected while they walked under three conditions: shoes without insole (SH), with internal heel lift insoles (IHLI) in shoes, and with external heal lift insole (EHLI). The tests were performed for both short and long legs. The pelvic kinematic and joint moment were measured with a motion capture system and force plate. Five walking trials were performed for each condition. The average value of five successful trials was used for further statistical analysis. Repeated measures ANCOVA with Bonferroni post hoc test were used for between-group comparisons (p ≤ 0.05). In both internal and external heel lift insoles (IHLI, EHLI), there was a significant decrease in the peak values of lateral and anterior pelvic tilts of the long leg, hip, and knee moments of a long leg and ankle moment of short leg (p ≤ 0.05). Furthermore, significant increases in peak values of lateral and anterior pelvic tilt of short leg in IHLI and EHLI were observed as compared to Shoe (SH) condition (p ≤ 0.01). In addition, a significant difference was observed between the IHLI and EHLI conditions in peak anterior pelvic tilt of long leg and plantar flexor moment of short leg (p=0.04; p= 0.04 respectively). Our findings indicate that both IHLI and EHLI can play an important role in controlling excessive pelvic movements in the sagittal and frontal planes in individuals with mild LLD during walking. Furthermore, the EHLI may have a better effect in preventing musculoskeletal injuries compared to the IHLI.

Keywords: kinematic, leg length discrepancy, shoe insole, walking

Procedia PDF Downloads 93
214 Assessment of the Electrical, Mechanical, and Thermal Nociceptive Thresholds for Stimulation and Pain Measurements at the Bovine Hind Limb

Authors: Samaneh Yavari, Christiane Pferrer, Elisabeth Engelke, Alexander Starke, Juergen Rehage

Abstract:

Background: Three nociceptive thresholds of thermal, electrical, and mechanical thresholds commonly use to evaluate the local anesthesia in many species, for instance, cow, horse, cat, dog, rabbit, and so on. Due to the lack of investigations to evaluate and/or validate such those nociceptive thresholds, our plan was the comparison of two-foot local anesthesia methods of Intravenous Regional Anesthesia (IVRA) and our modified four-point Nerve Block Anesthesia (NBA). Materials and Methods: Eight healthy nonpregnant nondairy Holstein Frisian cows in a cross-over study design were selected for this study. All cows divided into two different groups to receive two local anesthesia techniques of IVRA and our modified four-point NBA. Three thermal, electrical, and mechanical force and pinpricks were applied to evaluate the quality of local anesthesia methods before and after local anesthesia application. Results: The statistical evaluation demonstrated that our four-point NBA has a qualification to select as a standard foot local anesthesia. However, the recorded results of our study revealed no significant difference between two groups of local anesthesia techniques of IVRA and modified four-point NBA related to quality and duration of anesthesia stimulated by electrical, mechanical and thermal nociceptive stimuli. Conclusion and discussion: All three nociceptive threshold stimuli of electrical, mechanical and heat nociceptive thresholds can be applied to measure and evaluate the efficacy of foot local anesthesia of dairy cows. However, our study revealed no superiority of those three nociceptive methods to evaluate the duration and quality of bovine foot local anesthesia methods. Veterinarians to investigate the duration and quality of their selected anesthesia method can use any of those heat, mechanical, and electrical methods.

Keywords: mechanical, thermal, electrical threshold, IVRA, NBA, hind limb, dairy cow

Procedia PDF Downloads 221
213 Possible Neuroprotective Mechanism of Remote Limb Ischemic Post Conditioning against Global Cerebral Ischemic Injury

Authors: Sruthi Ramagiri, Rajeev Taliyan

Abstract:

Background and purpose: Recent investigations on ischemia and reperfusion injury postulate that transient ischemia of remote organs after a prolonged ischemic insult confers neuroprotection. However, the molecular mechanisms of the remote limb ischemic post-conditioning (RIPOC) are yet to be elucidated. The current study was designed to investigate the protective mechanism of RIPOC against cerebral ischemic injury using global model of stroke. Materials and methods: Global ischemic reperfusion injury (IR) was achieved by 30 minutes ischemia of cerebral artery, followed by reperfusion for 24 hours. Induction of global ischemia was followed by 4 brief episodes (30 seconds each) of ischemia and reperfusion of femoral artery to accomplish RIPOC. 5-Hydroxy Decanoic acid (5-HD), a KATP channel blocker (20 mg/kg) was administered after induction of global ischemia and RIPOC intervention. Results: IR injury ensue significant behavioural deficits as manifested by rotarod performance and spontaneous locomotor activity when compared to sham control. Furthermore, IR injury significantly increased oxidonitrative stress and infarct volume as evidenced by biochemical parameters (MDA, GSH, Nitrite, SOD) and 2,3,5-triphenyltetrazolium chloride (TTC) staining respectively. Moreover, RIPOC intervention ameliorated the behavioural performance, attenuated the oxidative stress and infarct volume when compared to IR injury group. However, administration of 5-HD increased the oxidative stress and infarct size while deteriorating the behavioural parameters when compared to RIPOC group. Conclusions: In a nutshell, cerebral IR injury has significantly induced the neuronal damage, whereas RIPOC intervention decreased the neuronal injury. Moreover, 5-HD abolished the neuroprotection offered by RIPOC indicating the putative role of KATP channel opening in RIPOC against cerebral ischemic injury.

Keywords: RIPOC, cerebral injury, KATP channel, neuroprotection

Procedia PDF Downloads 444
212 Association of Body Composition Parameters with Lower Limb Strength and Upper Limb Functional Capacity in Quilombola Remnants

Authors: Leonardo Costa Pereira, Frederico Santos Santana, Mauro Karnikowski, Luís Sinésio Silva Neto, Aline Oliveira Gomes, Marisete Peralta Safons, Margô Gomes De Oliveira Karnikowski

Abstract:

In Brazil, projections of population aging follow all world projections, the birth rate tends to be surpassed by the mortality rate around the year 2045. Historically, the population of Brazilian blacks suffered for several centuries from the oppression of dominant classes. A group, especially of blacks, stands out in relation to territorial, historical and social aspects, and for centuries they have isolated themselves in small communities, in order to maintain their freedom and culture. The isolation of the Quilombola communities generated socioeconomic effects as well as the health of these blacks. Thus, the objective of the present study is to verify the association of body composition parameters with lower and upper limb strength and functional capacity in Quilombola remnants. The research was approved by ethics committee (1,771,159). Anthropometric evaluations of hip and waist circumference, body mass and height were performed. In order to verify the body composition, the relationship between stature and body mass (BM) was performed, generating the body mass index (BMI), as well as the dual-energy X-ray absorptiometry (DEXA) test. The Time Up and Go (TUG) test was used to evaluate the functional capacity, and a maximum repetition test (1MR) for knee extension and handgrip (HG) was applied for strength magnitude analysis. Statistical analysis was performed using the statistical package SPSS 22.0. Shapiro Wilk's normality test was performed. For the possible correlations, the suggestions of the Pearson or Spearman tests were adopted. The results obtained after the interpretation identified that the sample (n = 18) was composed of 66.7% of female individuals with mean age of 66.07 ± 8.95 years. The sample’s body fat percentage (%BF) (35.65 ± 10.73) exceeds the recommendations for age group, as well as the anthropometric parameters of hip (90.91 ± 8.44cm) and waist circumference (80.37 ± 17.5cm). The relationship between height (1.55 ± 0.1m) and body mass (63.44 ± 11.25Kg) generated a BMI of 24.16 ± 7.09Kg/m2, that was considered normal. The TUG performance was 10.71 ± 1.85s. In the 1MR test, 46.67 ± 13.06Kg and in the HG 23.93±7.96Kgf were obtained, respectively. Correlation analyzes were characterized by the high frequency of significant correlations for height, dominant arm mass (DAM), %BF, 1MR and HG variables. In addition, correlations between HG and BM (r = 0.67, p = 0.005), height (r = 0.51, p = 0.004) and DAM (r = 0.55, p = 0.026) were also observed. The strength of the lower limbs correlates with BM (r = 0.69, p = 0.003), height (r = 0.62, p = 0.01) and DAM (r = 0.772, p = 0.001). In this way, we can conclude that not only the simple spatial relationship of mass and height can influence in predictive parameters of strength or functionality, being important the verification of the conditions of the corporal composition. For this population, height seems to be a good predictor of strength and body composition.

Keywords: African Continental Ancestry Group, body composition, functional capacity, strength

Procedia PDF Downloads 251
211 Energy Efficient Autonomous Lower Limb Exoskeleton for Human Motion Enhancement

Authors: Nazim Mir-Nasiri, Hudyjaya Siswoyo Jo

Abstract:

The paper describes conceptual design, control strategies, and partial simulation for a new fully autonomous lower limb wearable exoskeleton system for human motion enhancement that can support its weight and increase strength and endurance. Various problems still remain to be solved where the most important is the creation of a power and cost efficient system that will allow an exoskeleton to operate for extended period without batteries being frequently recharged. The designed exoskeleton is enabling to decouple the weight/mass carrying function of the system from the forward motion function which reduces the power and size of propulsion motors and thus the overall weight, cost of the system. The decoupling takes place by blocking the motion at knee joint by placing passive air cylinder across the joint. The cylinder is actuated when the knee angle has reached the minimum allowed value to bend. The value of the minimum bending angle depends on usual walk style of the subject. The mechanism of the exoskeleton features a seat to rest the subject’s body weight at the moment of blocking the knee joint motion. The mechanical structure of each leg has six degrees of freedom: four at the hip, one at the knee, and one at the ankle. Exoskeleton legs are attached to subject legs by using flexible cuffs. The operation of all actuators depends on the amount of pressure felt by the feet pressure sensors and knee angle sensor. The sensor readings depend on actual posture of the subject and can be classified in three distinct cases: subject stands on one leg, subject stands still on both legs and subject stands on both legs but transit its weight from one leg to other. This exoskeleton is power efficient because electrical motors are smaller in size and did not participate in supporting the weight like in all other existing exoskeleton designs.

Keywords: energy efficient system, exoskeleton, motion enhancement, robotics

Procedia PDF Downloads 345
210 Work Related and Psychosocial Risk Factors for Musculoskeletal Disorders among Workers in an Automated flexible Assembly Line in India

Authors: Rohin Rameswarapu, Sameer Valsangkar

Abstract:

Background: Globally, musculoskeletal disorders are the largest single cause of work-related illnesses accounting for over 33% of all newly reported occupational illnesses. Risk factors for MSD need to be delineated to suggest means for amelioration. Material and methods: In this current cross-sectional study, the prevalence of MSDs among workers in an electrical company assembly line, the socio-demographic and job characteristics associated with MSD were obtained through a semi-structured questionnaire. A quantitative assessment of the physical risk factors through the Rapid Upper Limb Assessment (RULA) tool, and measurement of psychosocial risk factors through a Likert scale was obtained. Statistical analysis was conducted using Epi-info software and descriptive and inferential statistics including chi-square and unpaired t test were obtained. Results: A total of 263 workers consented and participated in the study. Among these workers, 200 (76%) suffered from MSD. Most of the workers were aged between 18–27 years and majority of the workers were women with 198 (75.2%) of the 263 workers being women. A chi square test was significant for association between male gender and MSD with a P value of 0.007. Among the MSD positive group, 4 (2%) had a grand score of 5, 10 (5%) had a grand score of 6 and 186 (93%) had a grand score of 7 on RULA. There were significant differences between the non-MSD and MSD group on five out of the seven psychosocial domains, namely job demand, job monotony, co-worker support, decision control and family and environment domains. Discussion: The current cross-sectional study demonstrates a high prevalence of MSD among assembly line works with inherent physical and psychosocial risk factors and recommends that not only physical risk factors, addressing psychosocial risk factors through proper ergonomic means is also essential to the well-being of the employee.

Keywords: musculoskeletal disorders, India, occupational health, Rapid Upper Limb Assessment (RULA)

Procedia PDF Downloads 317
209 The Extent of Proliferation, Apoptosis and Angiogenesis at the Site of Injury Determine the Course of Healing Either as Scar Free or as Scarred One in the Appendages of Lizard

Authors: Isha Ranadive, Sonam Patel, Suresh Balakrishnan

Abstract:

It has been observed that in lizards wound can be healed by either a scar free mechanism or by scarring. The animal model used to study both these healing processes was Northern House Gecko. In lizard, the tail when amputated heals by scar free mechanism which allows it to regenerate, the same is not seen when the limb is amputated. Proliferation, apoptosis, and angiogenesis are the main events which succeed an injury. We observed that proliferation of the cells beneath the wound epidermis was much higher in case of wound healing in tail. This could be because after the wound gets covered by the epithelium, it enters in to a cross-talk with the underlying mesenchyme to recruit a pool of blastemal cells which proliferate and later differentiate to form the lost part through epimorphic regeneration. This was substantiated by mRNA expression levels of various FGFs which facilitate the cross-talk and also by PCNA which is a marker for proliferation. Western blot result reaffirms the same notion. However, in case of the limb, the rate of apoptosis was more than proliferation as there are a lot of debris that needs to be removed. We came to this conclusion as we observed that p53 the apoptotic gene was highly upregulated in case of the scarred tissue. Further, we confirmed this result by checking the anti-apoptotic gene bcl2 and found it to be significantly down-regulated. As we noticed heightened proliferation in the case of scar-free wound healing in tail, angiogenesis was targeted for the study. This is because, when the cells are proliferating they require constant supply of blood and hence neo-vascularization is inevitable. It was observed that the marker of angiogenesis, VEGF, was expressed more during wound healing as compared to the resting stage of tail. Moreover, a high up-regulation was seen in KDR, a receptor of VEGF. Thus, this study reveals how proliferation, apoptosis, and angiogenesis play a key role in the scar-free as well as scarred wound healing.

Keywords: epimorphic regeneration, injury, northern house gecko, wound healing

Procedia PDF Downloads 219
208 Image Enhancement Algorithm of Photoacoustic Tomography Using Active Contour Filtering

Authors: Prasannakumar Palaniappan, Dong Ho Shin, Chul Gyu Song

Abstract:

The photoacoustic images are obtained from a custom developed linear array photoacoustic tomography system. The biological specimens are imitated by conducting phantom tests in order to retrieve a fully functional photoacoustic image. The acquired image undergoes the active region based contour filtering to remove the noise and accurately segment the object area for further processing. The universal back projection method is used as the image reconstruction algorithm. The active contour filtering is analyzed by evaluating the signal to noise ratio and comparing it with the other filtering methods.

Keywords: contour filtering, linear array, photoacoustic tomography, universal back projection

Procedia PDF Downloads 377
207 The Impact of Barefoot versus Shod Running on Lower Limb Gait Cycle Pattern among Recreational Club Runners in Durban, South Africa

Authors: Siyabonga Kunene, Calvin Shipley

Abstract:

Introduction: Despite health benefits that come with running, injuries are common with prevalence ranging between 18.2% and 92.4% worldwide. Differences in gait patterns between barefoot and shod running, can determine traits that could lead to running injuries. The aim was to assess and compare lower limb gait cycle patterns between barefoot and shod running among runners. Methods: An experimental same-subject study design was used. The study population consisted of male and female adult recreational runners who were injury free from a running club in Durban. A convenience sampling method was used and 14 participants were recruited. The study was conducted in the physiotherapy performance laboratory at the University of KwaZulu-Natal. A Woodway Desmo Treadmill and KinePro gait analysis system were used. Descriptive & inferential statistics were analysed using Microsoft Excel and Intercooled Stata. Results: Participants included a greater percentage of females (57.1%, n = 8) than males (42.9%, n = 6). The mean population age was 38.57. A significant difference (p < 0.0009) between barefoot cadence (177.9236steps/min) and shod cadence (171.9445steps/min) was observed. Right (0.261s) and left (0.257s) barefoot stand phase was shorter than right (0.273s) and left (0.270s) shod stand phase. Right barefoot swing phase exhibited less significant (0.420s) results when compared to right shod swing phase (0.427s), whereas left barefoot swing phase was quicker (0.416s) than left shod swing phase (0.432s). Significant differences between barefoot and shod stand (p < 0.009) and swing (p < 0.040) phase symmetry occurred. Conclusion: A considerable difference was found between barefoot and shod running gait cycle patterns among participants. This difference may play a role in prevention of running related injuries.

Keywords: barefoot running, shod running, gait cycle pattern, same-subject study design

Procedia PDF Downloads 225
206 Calling Persons with Disability as Divine: Exploring and Critiquing Meanings of Divyang (The One with a Divine Limb) in the Indian Context

Authors: Vinay Suhalka

Abstract:

In India, the official nomenclature used by the State for persons with disability is divyang (literally, the one with a divine limb), a word coming from the Sanskrit language. Disability thus gets portrayed as divine, at least in the welfare sector from where it flows down even to the popular imagination where it gets equated to divinity. This paper looks at reference to persons with disabilities as divyangs and goes on to discusses what such usage for an already marginalized group achieves and misses out. The issue of nomenclature and language has always been a contested one when it comes to disability. At the same time, there is also an issue of who determines these labels for the persons with disability. Nomenclature and language used for disability can have real consequences for the population of persons with disability as it may empower or disempower them. Thus, this paper looks at the issue of what it means for persons with disabilities as ‘exceptionally gifted’ and hence divyang. Language can be a powerful tool to communicate meanings and messages associated with a term. When the persons with disabilities as a group are described as ‘exceptionally gifted, talented and the source of inspiration’, it essentially stereotypes and marginalizes them by putting a burden of performance that all of them ought to be achievers, and it is only then that they would be assimilated in the larger society. This paper also argues that such a situation creates a ‘double bind’ where the person is always trying to match up to the labels (the disabled as ‘achiever, overcomer, inspirational’) created by somebody else and looks at self through the eyes of others. This conceptual paper also presents an overview of disability labels while simultaneously looking at projecting disability as divinity which has the potential to wrongly portray the lives of persons with disability in India due to the official usage of the term. It also explores the question of visibility of disability since the idea of divyang implicitly assumes that all disabilities are visible. In reality, however, it may not be the case simply because all forms of disabilities are not visible, people may choose not to visibilize their disabilities if they can and pass as able-bodied, fearing the stigma that surrounds disability. Finally, it argues for an increased focus on understanding the everyday lived realities of those with disability in order to regard it as an important form of difference which could be a potential resource for the society.

Keywords: persons with disability, labels, language use, divinity

Procedia PDF Downloads 128
205 Detecting Rat’s Kidney Inflammation Using Real Time Photoacoustic Tomography

Authors: M. Y. Lee, D. H. Shin, S. H. Park, W.C. Ham, S.K. Ko, C. G. Song

Abstract:

Photoacoustic Tomography (PAT) is a promising medical imaging modality that combines optical imaging contrast with the spatial resolution of ultrasound imaging. It can also distinguish the changes in biological features. But, real-time PAT system should be confirmed due to photoacoustic effect for tissue. Thus, we have developed a real-time PAT system using a custom-developed data acquisition board and ultrasound linear probe. To evaluate performance of our system, phantom test was performed. As a result of those experiments, the system showed satisfactory performance and its usefulness has been confirmed. We monitored the degradation of inflammation which induced on the rat’s kidney using real-time PAT.

Keywords: photoacoustic tomography, inflammation detection, rat, kidney, contrast agent, ultrasound

Procedia PDF Downloads 419
204 Comparative Study of Analgesic Efficacy of Ultrasound Guided Femoral Nerve Block Versus Intravenous Fentanyl Injection in Fracture Femur Patients at Emergency Department

Authors: Asmaa Hamdy, Israa Nassar, Tarek Aly

Abstract:

Introduction: Femoral fractures are the most common presentation in the Emergency Department (ED), and they can present as isolated injuries or as part of a polytrauma situation. To provide optimum pain management care to these patients, practitioners must be well prepared and current with utilizing modern evidence-based knowledge and practices. Management of pain associated with fracture femur in the emergency department has a critical role in the satisfaction of patients and preventing further complications. This study aimed to evaluate the analgesic efficacy of ultrasound-guided femoral nerve block compared with intravenous fentanyl in fractures of the femur in patients presented to the Emergency Department. Patients and Methods: Fifty patients with femur fractures were divided into two groups: Group A: In this group (twenty-five patients) were given intravenous fentanyl 2 micro-grams/kg and re-assessed for pain by Visual Analogue Score (VAS). Group B: In this group (twenty-five patients) underwent ultrasonography-guided femoral nerve block and were re-assessed for pain by VAS. Results: VAS score on the movement of the fractured limb between group A and group B at a 10-minute post-intervention period shows P= 0.043, and hence the difference is significant. VAS score on the movement of the fractured limb between group A and group B during a 10-minute post-intervention period showed a significant difference. Seventeen patients in group A had major PID with a percentage of 63% VS 10 patients in group B with a percentage of 37%. conclusion: both femoral nerve block and intravenous fentanyl are effective in relieving pain in patients with femur fractures. But femoral nerve block provides better and more intense analgesia and major pain intensity difference in less time. Moreover, the use of FNB had fewer side effects and more Hemodynamics stability compared to opioids.

Keywords: femur fracture, nerve block, fentanyl, ultrasound guided

Procedia PDF Downloads 72
203 Dosimetric Comparison among Different Head and Neck Radiotherapy Techniques Using PRESAGE™ Dosimeter

Authors: Jalil ur Rehman, Ramesh C. Tailor, Muhammad Isa Khan, Jahnzeeb Ashraf, Muhammad Afzal, Geofferry S. Ibbott

Abstract:

Purpose: The purpose of this analysis was to investigate dose distribution of different techniques (3D-CRT, IMRT and VMAT) of head and neck cancer using 3-dimensional dosimeter called PRESAGETM Dosimeter. Materials and Methods: Computer tomography (CT) scans of radiological physics center (RPC) head and neck anthropomorphic phantom with both RPC standard insert and PRESAGETM insert were acquired separated with Philipp’s CT scanner and both CT scans were exported via DICOM to the Pinnacle version 9.4 treatment planning system (TPS). Each plan was delivered twice to the RPC phantom first containing the RPC standard insert having TLD and film dosimeters and then again containing the Presage insert having 3-D dosimeter (PRESAGETM) by using a Varian True Beam linear accelerator. After irradiation, the standard insert including point dose measurements (TLD) and planar Gafchromic® EBT film measurement were read using RPC standard procedure. The 3D dose distribution from PRESAGETM was read out with the Duke Midsized optical scanner dedicated to RPC (DMOS-RPC). Dose volume histogram (DVH), mean and maximal doses for organs at risk were calculated and compared among each head and neck technique. The prescription dose was same for all head and neck radiotherapy techniques which was 6.60 Gy/friction. Beam profile comparison and gamma analysis were used to quantify agreements among film measurement, PRESAGETM measurement and calculated dose distribution. Quality assurances of all plans were performed by using ArcCHECK method. Results: VMAT delivered the lowest mean and maximum doses to organ at risk (spinal cord, parotid) than IMRT and 3DCRT. Such dose distribution was verified by absolute dose distribution using thermoluminescent dosimeter (TLD) system. The central axial, sagittal and coronal planes were evaluated using 2D gamma map criteria(± 5%/3 mm) and results were 99.82% (axial), 99.78% (sagital), 98.38% (coronal) for VMAT plan and found the agreement between PRESAGE and pinnacle was better than IMRT and 3D-CRT plan excludes a 7 mm rim at the edge of the dosimeter. Profile showed good agreement for all plans between film, PRESAGE and pinnacle and 3D gamma was performed for PTV and OARs, VMAT and 3DCRT endow with better agreement than IMRT. Conclusion: VMAT delivered lowered mean and maximal doses to organs at risk and better PTV coverage during head and neck radiotherapy. TLD, EBT film and PRESAGETM dosimeters suggest that VMAT was better for the treatment of head and neck cancer than IMRT and 3D-CRT.

Keywords: RPC, 3DCRT, IMRT, VMAT, EBT2 film, TLD, PRESAGETM

Procedia PDF Downloads 362
202 The Effects of Adding Vibrotactile Feedback to Upper Limb Performance during Dual-Tasking and Response to Misleading Visual Feedback

Authors: Sigal Portnoy, Jason Friedman, Eitan Raveh

Abstract:

Introduction: Sensory substitution is possible due to the capacity of our brain to adapt to information transmitted by a synthetic receptor via an alternative sensory system. Practical sensory substitution systems are being developed in order to increase the functionality of individuals with sensory loss, e.g. amputees. For upper limb prosthetic-users the loss of tactile feedback compels them to allocate visual attention to their prosthesis. The effect of adding vibrotactile feedback (VTF) to the applied force has been studied, however its effect on the allocation if visual attention during dual-tasking and the response during misleading visual feedback have not been studied. We hypothesized that VTF will improve the performance and reduce visual attention during dual-task assignments in healthy individuals using a robotic hand and improve the performance in a standardized functional test, despite the presence of misleading visual feedback. Methods: For the dual-task paradigm, twenty healthy subjects were instructed to toggle two keyboard arrow keys with the left hand to retain a moving virtual car on a road on a screen. During the game, instructions for various activities, e.g. mix the sugar in the glass with a spoon, appeared on the screen. The subject performed these tasks with a robotic hand, attached to the right hand. The robotic hand was controlled by the activity of the flexors and extensors of the right wrist, recorded using surface EMG electrodes. Pressure sensors were attached at the tips of the robotic hand and induced VTF using vibrotactile actuators attached to the right arm of the subject. An eye-tracking system tracked to visual attention of the subject during the trials. The trials were repeated twice, with and without the VTF. Additionally, the subjects performed the modified box and blocks, hidden from eyesight, in a motion laboratory. A virtual presentation of a misleading visual feedback was be presented on a screen so that twice during the trial, the virtual block fell while the physical block was still held by the subject. Results: This is an ongoing study, which current results are detailed below. We are continuing these trials with transradial myoelectric prosthesis-users. In the healthy group, the VTF did not reduce the visual attention or improve performance during dual-tasking for the tasks that were typed transfer-to-target, e.g. place the eraser on the shelf. An improvement was observed for other tasks. For example, the average±standard deviation of time to complete the sugar-mixing task was 13.7±17.2s and 19.3±9.1s with and without the VTF, respectively. Also, the number of gaze shifts from the screen to the hand during this task were 15.5±23.7 and 20.0±11.6, with and without the VTF, respectively. The response of the subjects to the misleading visual feedback did not differ between the two conditions, i.e. with and without VTF. Conclusions: Our interim results suggest that the performance of certain activities of daily living may be improved by VTF. The substitution of visual sensory input by tactile feedback might require a long training period so that brain plasticity can occur and allow adaptation to the new condition.

Keywords: prosthetics, rehabilitation, sensory substitution, upper limb amputation

Procedia PDF Downloads 313
201 Preoperative versus Postoperative Radiation Therapy in Patients with Soft Tissue Sarcoma of the Extremity

Authors: AliAkbar Hafezi, Jalal Taherian, Jamshid Abedi, Mahsa Elahi, Behnam Kadkhodaei

Abstract:

Background: Soft tissue sarcomas (STS) are generally treated with a combination of limb preservation surgery and radiation therapy. Today, preoperative radiation therapy is considered for accurate treatment volume and smaller field size. Therefore, this study was performed to compare preoperative with postoperative radiation therapy in patients with extremity STS. Methods: In this non-randomized clinical trial, patients with localized extremity STS referred to the orthopedic clinics in Iran from 2021 to 2023 were studied. Patients were randomly divided into two groups: preoperative and postoperative radiation therapy. The two groups of patients were compared in terms of acute (wound dehiscence and infection) and late (limb edema, subcutaneous fibrosis, and joint stiffness) complications and their severity, as well as local recurrence and other one-year outcomes. Results: A total of 80 patients with localized extremity STS were evaluated in two treatment groups. The groups were matched in terms of age, sex, history of diabetes mellitus, hypertension, smoking, involved side, involved extremity, lesion location, and tumor histopathology. The acute complications of treatment in the two groups of patients did not differ significantly (P > 0.05). Of the late complications, only joint stiffness between the two groups had significant statistical differences (P < 0.001). The severity of all three late complications in the postoperative radiation therapy group was significantly higher (P < 0.05). There was no significant difference between the two groups in terms of the rate of local recurrence of other one-year outcomes (P > 0.05). Conclusion: This study showed that in patients with localized extremity STS, the two therapeutic approaches of adjuvant and neoadjuvant radiation therapy did not differ significantly in terms of local recurrence and distant metastasis during the one-year follow-up period and due to fewer late complications in preoperative radiotherapy group, this treatment approach can be a better choice than postoperative radiation therapy.

Keywords: soft tissue sarcoma, extremity, preoperative radiation therapy, postoperative radiation therapy

Procedia PDF Downloads 13
200 Effectiveness of Imagery Compared with Exercise Training on Hip Abductor Strength and EMG Production in Healthy Adults

Authors: Majid Manawer Alenezi, Gavin Lawrence, Hans-Peter Kubis

Abstract:

Imagery training could be an important treatment for muscle function improvements in patients who are facing limitations in exercise training by pain or other adverse symptoms. However, recent studies are mostly limited to small muscle groups and are often contradictory. Moreover, a possible bilateral transfer effect of imagery training has not been examined. We, therefore, investigated the effectiveness of unilateral imagery training in comparison with exercise training on hip abductor muscle strength and EMG. Additionally, both limbs were assessed to investigate bilateral transfer effects. Healthy individuals took part in an imagery or exercise training intervention for two weeks and were assesses pre and post training. Participants (n=30), after randomization into an imagery and an exercise group, trained 5 times a week under supervision with additional self-performed training on the weekends. The training consisted of performing, or to imagine, 5 maximal isometric hip abductor contractions (= one set), repeating the set 7 times. All measurements and trainings were performed laying on the side on a dynamometer table. The imagery script combined kinesthetic and visual imagery with internal perspective for producing imagined maximal hip abduction contractions. The exercise group performed the same number of tasks but performing the maximal hip abductor contractions. Maximal hip abduction strength and EMG amplitudes were measured of right and left limbs pre- and post-training period. Additionally, handgrip strength and right shoulder abduction (Strength and EMG) were measured. Using mixed model ANOVA (strength measures) and Wilcoxen-tests (EMGs), data revealed a significant increase in hip abductor strength production in the imagery group on the trained right limb (~6%). However, this was not reported for the exercise group. Additionally, the left hip abduction strength (not used for training) did not show a main effect in strength, however, there was a significant interaction of group and time revealing that the strength increased in the imagery group while it remained constant in the exercise group. EMG recordings supported the strength findings showing significant elevation of EMG amplitudes after imagery training on right and left side, while the exercise training group did not show any changes. Moreover, measures of handgrip strength and shoulder abduction showed no effects over time and no interactions in both groups. Experiments showed that imagery training is a suitable method for effectively increasing functional parameters of larger limb muscles (strength and EMG) which were enhanced on both sides (trained and untrained) confirming a bilateral transfer effect. Indeed, exercise training did not reveal any increases in the parameters above omitting functional improvements. The healthy individuals tested might not easily achieve benefits from exercise training within the time tested. However, it is evident that imagery training is effective in increasing the central motor command towards the muscles and that the effect seems to be segmental (no increase in handgrip strength and shoulder abduction parameters) and affects both sides (trained and untrained). In conclusion, imagery training was effective in functional improvements in limb muscles and produced a bilateral transfer on strength and EMG measures.

Keywords: imagery, exercise, physiotherapy, motor imagery

Procedia PDF Downloads 202
199 Fabrication of Optical Tissue Phantoms Simulating Human Skin and Their Application

Authors: Jihoon Park, Sungkon Yu, Byungjo Jung

Abstract:

Although various optical tissue phantoms (OTPs) simulating human skin have been actively studied, their completeness is unclear because skin tissue has the intricate optical property and complicated structure disturbing the optical simulation. In this study, we designed multilayer OTP mimicking skin structure, and fabricated OTP models simulating skin-blood vessel and skin pigmentation in the skin, which are useful in Biomedical optics filed. The OTPs were characterized with the optical property and the cross-sectional structure, and analyzed by using various optical tools such as a laser speckle imaging system, OCT and a digital microscope to show the practicality. The measured optical property was within 5% error, and the thickness of each layer was uniform within 10% error in micrometer scale.

Keywords: blood vessel, optical tissue phantom, optical property, skin tissue, pigmentation

Procedia PDF Downloads 414
198 Characterization of the MOSkin Dosimeter for Accumulated Dose Assessment in Computed Tomography

Authors: Lenon M. Pereira, Helen J. Khoury, Marcos E. A. Andrade, Dean L. Cutajar, Vinicius S. M. Barros, Anatoly B. Rozenfeld

Abstract:

With the increase of beam widths and the advent of multiple-slice and helical scanners, concerns related to the current dose measurement protocols and instrumentation in computed tomography (CT) have arisen. The current methodology of dose evaluation, which is based on the measurement of the integral of a single slice dose profile using a 100 mm long cylinder ionization chamber (Ca,100 and CPPMA, 100), has been shown to be inadequate for wide beams as it does not collect enough of the scatter-tails to make an accurate measurement. In addition, a long ionization chamber does not offer a good representation of the dose profile when tube current modulation is used. An alternative approach has been suggested by translating smaller detectors through the beam plane and assessing the accumulated dose trough the integral of the dose profile, which can be done for any arbitrary length in phantoms or in the air. For this purpose, a MOSFET dosimeter of small dosimetric volume was used. One of its recently designed versions is known as the MOSkin, which is developed by the Centre for Medical Radiation Physics at the University of Wollongong, and measures the radiation dose at a water equivalent depth of 0.07 mm, allowing the evaluation of skin dose when placed at the surface, or internal point doses when placed within a phantom. Thus, the aim of this research was to characterize the response of the MOSkin dosimeter for X-ray CT beams and to evaluate its application for the accumulated dose assessment. Initially, tests using an industrial x-ray unit were carried out at the Laboratory of Ionization Radiation Metrology (LMRI) of Federal University of Pernambuco, in order to investigate the sensitivity, energy dependence, angular dependence, and reproducibility of the dose response for the device for the standard radiation qualities RQT 8, RQT 9 and RQT 10. Finally, the MOSkin was used for the accumulated dose evaluation of scans using a Philips Brilliance 6 CT unit, with comparisons made between the CPPMA,100 value assessed with a pencil ionization chamber (PTW Freiburg TW 30009). Both dosimeters were placed in the center of a PMMA head phantom (diameter of 16 cm) and exposed in the axial mode with collimation of 9 mm, 250 mAs and 120 kV. The results have shown that the MOSkin response was linear with doses in the CT range and reproducible (98.52%). The sensitivity for a single MOSkin in mV/cGy was as follows: 9.208, 7.691 and 6.723 for the RQT 8, RQT 9 and RQT 10 beams qualities respectively. The energy dependence varied up to a factor of ±1.19 among those energies and angular dependence was not greater than 7.78% within the angle range from 0 to 90 degrees. The accumulated dose and the CPMMA, 100 value were 3,97 and 3,79 cGy respectively, which were statistically equivalent within the 95% confidence level. The MOSkin was shown to be a good alternative for CT dose profile measurements and more than adequate to provide accumulated dose assessments for CT procedures.

Keywords: computed tomography dosimetry, MOSFET, MOSkin, semiconductor dosimetry

Procedia PDF Downloads 283
197 Kinematic Analysis of Human Gait for Typical Postures of Walking, Running and Cart Pulling

Authors: Nupur Karmaker, Hasin Aupama Azhari, Abdul Al Mortuza, Abhijit Chanda, Golam Abu Zakaria

Abstract:

Purpose: The purpose of gait analysis is to determine the biomechanics of the joint, phases of gait cycle, graphical and analytical analysis of degree of rotation, analysis of the electrical activity of muscles and force exerted on the hip joint at different locomotion during walking, running and cart pulling. Methods and Materials: Visual gait analysis and electromyography method has been used to detect the degree of rotation of joints and electrical activity of muscles. In cinematography method an object is observed from different sides and takes its video. Cart pulling length has been divided into frames with respect to time by using video splitter software. Phases of gait cycle, degree of rotation of joints, EMG profile and force analysis during walking and running has been taken from different papers. Gait cycle and degree of rotation of joints during cart pulling has been prepared by using video camera, stop watch, video splitter software and Microsoft Excel. Results and Discussion: During the cart pulling the force exerted on hip is the resultant of various forces. The force on hip is the vector sum of the force Fg= mg, due the body of weight of the person and Fa= ma, due to the velocity. Maximum stance phase shows during cart pulling and minimum shows during running. During cart pulling shows maximum degree of rotation of hip joint, knee: running, and ankle: cart pulling. During walking, it has been observed minimum degree of rotation of hip, ankle: during running. During cart pulling, dynamic force depends on the walking velocity, body weight and load weight. Conclusions: 80% people suffer gait related disease with increasing their age. Proper care should take during cart pulling. It will be better to establish the gait laboratory to determine the gait related diseases. If the way of cart pulling is changed i.e the design of cart pulling machine, load bearing system is changed then it would possible to reduce the risk of limb loss, flat foot syndrome and varicose vein in lower limb.

Keywords: kinematic, gait, gait lab, phase, force analysis

Procedia PDF Downloads 553
196 Robotic Arm Allowing a Diabetic Quadriplegic Patient to Self-Administer Insulin

Authors: L. Parisi

Abstract:

A method which allows a diabetic quadriplegic patient that has had four limb amputations (above the knee and elbow) to self-administer injections of insulin has been designed. The aim of this research project is to improve a quadriplegic patient’s self-management, affected by diabetes, by designing a suitable device for self-administering insulin.The quadriplegic patient affected by diabetes has to be able to self-administer insulin safely and independently to guarantee stable healthy conditions. The device also should be designed to adapt to a number of different varying personal characteristics such as height and body weight.

Keywords: robotic arm, self-administration, insulin, diabetes, quadriplegia

Procedia PDF Downloads 335
195 A Rare Case of Synchronous Colon Adenocarcinoma

Authors: Mohamed Shafi Bin Mahboob Ali

Abstract:

Introduction: Synchronous tumor is defined as the presence of more than one primary malignant lesion in the same patient at the indexed diagnosis. It is a rare occurrence, especially in the spectrum of colorectal cancer, which accounts for less than 4%. The underlying pathology of a synchronous tumor is thought to be due to a genomic factor, which is microsatellite instability (MIS) with the involvement of BRAF, KRAS, and the GSRM1 gene. There are no specific sites of occurrence for the synchronous colorectal tumor, but many studies have shown that a synchronous tumor has about 43% predominance in the ascending colon with rarity in the sigmoid colon. Case Report: We reported a case of a young lady in the middle of her 30's with no family history of colorectal cancer that was diagnosed with a synchronous adenocarcinoma at the descending colon and rectosigmoid region. The lady's presentation was quite perplexing as she presented to the district hospital initially with simple, uncomplicated hemorrhoids and constipation. She was then referred to our center for further management as she developed a 'football' sized right gluteal swelling with a complete intestinal obstruction and bilateral lower-limb paralysis. We performed a CT scan and biopsy of the lesion, which found that the tumor engulfed the sacrococcygeal region with more than one primary lesion in the colon as well as secondaries in the liver. The patient was operated on after a multidisciplinary meeting was held. Pelvic exenteration with tumor debulking and anterior resection were performed. Postoperatively, she was referred to the oncology team for chemotherapy. She had a tremendous recovery in eight months' time with a partial regain of her lower limb power. The patient is still under our follow-up with an improved quality of life post-intervention. Discussion: Synchronous colon cancer is rare, with an incidence of 2.4% to 12.4%. It has male predominance and is pathologically more advanced compared to a single colon lesion. Down staging the disease by means of chemoradiotherapy has shown to be effective in managing this tumor. It is seen commonly on the right colon, but in our case, we found it on the left colon and the rectosigmoid. Conclusion: Managing a synchronous colon tumor could be challenging to surgeons, especially in deciding the extent of resection and postoperative functional outcomes of the bowel; thus, individual treatment strategies are needed to tackle this pathology.

Keywords: synchronous, colon, tumor, adenocarcinoma

Procedia PDF Downloads 83
194 The Effect of Bihemisferic Transcranial Direct Current Stimulation Therapy on Upper Extremity Motor Functions in Stroke Patients

Authors: Dilek Cetin Alisar, Oya Umit Yemisci, Selin Ozen, Seyhan Sozay

Abstract:

New approaches and treatment modalities are being developed to make patients more functional and independent in stroke rehabilitation. One of these approaches is transcranial direct stimulation therapy (tDCS), which aims to improve the hemiplegic upper limb function of stroke patients. tDCS therapy is not in the routine rehabilitation program; however, the studies about tDCS therapy on stroke rehabilitation was increased in recent years. Evaluate the effect of tDCS treatment on upper extremity motor function in patients with subacute stroke was aimed in our study. 32 stroke patients (16 tDCS group, 16 sham groups) who were hospitalized for rehabilitation in Başkent University Physical Medicine and Rehabilitation Clinic between 01.08.2016-20.01-2018 were included in the study. The conventional upper limb rehabilitation program was used for both tDCS and control group patients for 3 weeks, 5 days a week, for 60-120 minutes a day. In addition to the conventional stroke rehabilitation program in the tDAS group, bihemispheric tDCS was administered for 30 minutes daily. Patients were evaluated before treatment and after 1 week of treatment. Functional independence measure self-care score (FIM), Brunnstorm Recovery Stage (BRS), and Fugl-Meyer (FM) upper extremity motor function scale were used. There was no difference in demographic characteristics between the groups. There were no significant differences between BRS and FM scores in two groups, but there was a significant difference FIM score (p=0.05. FIM, BRS, and FM scores are significantly in the tDCS group, when before therapy and after 1 week of therapy, however, no difference is found in the shame group (p < 0,001). When FBS and FM scores were compared, there were statistical significant differences in tDCS group (p < 0,001). In conclusion, this randomized double-blind study showed that bihemispheric tDCS treatment was found to be superior to upper extremity motor and functional enhancement in addition to conventional rehabilitation methods in subacute stroke patients. In order for tDCS therapy to be used routinely in stroke rehabilitation, there is a need for more comprehensive, long-termed, randomized controlled clinical trials in order to find answers to many questions, such as the duration and intensity of treatment.

Keywords: cortical stimulation, motor function, rehabilitation, stroke

Procedia PDF Downloads 104
193 The Physical and Physiological Profile of Professional Muay Thai Boxers

Authors: Lucy Horrobin, Rebecca Fores

Abstract:

Background: Muay Thai is an increasingly popular combat sport worldwide. Further academic research in the sport will contribute to its professional development. This research sought to produce normative data in relation to the physical and physiological characteristics of professional Muay Thai boxers, as, currently no such data exists. The ultimate aim being to inform appropriate training programs and to facilitate coaching. Methods: N = 9 professional, adult, male Muay Thai boxers were assessed for the following anthropometric, physical and physiological characteristics, using validated methods of assessment: body fat, hamstring flexibility, maximal dynamic upper body strength, lower limb peak power, upper body muscular endurance and aerobic capacity. Raw data scores were analysed for mean, range and SD and where applicable were expressed relative to body mass (BM). Results: Results showed similar characteristics to those found in other combat sports. Low percentages of body fat (mean±SD) 8.54 ± 1.16 allow for optimal power to weight ratios. Highly developed aerobic capacity (mean ±SD) 61.56 ± 5.13 ml.min.kg facilitate recovery and power maintenance throughout bouts. Lower limb peak power output values of (mean ± SD) 12.60 ± 2.09 W/kg indicate that Muay Thai boxers are amongst the most powerful of combat sport athletes. However, maximal dynamic upper body strength scores of (mean±SD) 1.14 kg/kg ± 0.18 were in only the 60th percentile of normative data for the general population and muscular endurance scores (mean±SD) 31.55 ± 11.95 and flexibility scores (mean±SD) 19.55 ± 11.89 cm expressed wide standard deviation. These results might suggest that these characteristics are insignificant in Muay Thai or under-developed, perhaps due to deficient training programs. Implications: This research provides the first normative data of physical and physiological characteristics of Muay Thai boxers. The findings of this study would aid trainers and coaches when designing effective evidence-based training programs. Furthermore, it provides a foundation for further research relating to physiology in Muay Thai. Areas of further study could be determining the physiological demands of a full rules bout and the effects of evidence-based training programs on performance.

Keywords: fitness testing, Muay Thai, physiology, strength and conditioning

Procedia PDF Downloads 198
192 Gaussian Mixture Model Based Identification of Arterial Wall Movement for Computation of Distension Waveform

Authors: Ravindra B. Patil, P. Krishnamoorthy, Shriram Sethuraman

Abstract:

This work proposes a novel Gaussian Mixture Model (GMM) based approach for accurate tracking of the arterial wall and subsequent computation of the distension waveform using Radio Frequency (RF) ultrasound signal. The approach was evaluated on ultrasound RF data acquired using a prototype ultrasound system from an artery mimicking flow phantom. The effectiveness of the proposed algorithm is demonstrated by comparing with existing wall tracking algorithms. The experimental results show that the proposed method provides 20% reduction in the error margin compared to the existing approaches in tracking the arterial wall movement. This approach coupled with ultrasound system can be used to estimate the arterial compliance parameters required for screening of cardiovascular related disorders.

Keywords: distension waveform, Gaussian Mixture Model, RF ultrasound, arterial wall movement

Procedia PDF Downloads 475
191 X-Ray Energy Release in the Solar Eruptive Flare from 6th of September 2012

Authors: Mirabbos Mirkamalov, Zavkiddin Mirtoshev

Abstract:

The M 1.6 class flare occurred on 6th of September 2012. Our observations correspond to the active region NOAA 11560 with the heliographic coordinates N04W71. The event took place between 04:00 UT and 04:45 UT, and was close to the solar limb at the western region. The flare temperature correlates with flux peak, increases for a short period (between 04:08 UT and 04:12 UT), rises impulsively, attains a maximum value of about 17 MK at 04:12 UT and gradually decreases after peak value. Around the peak we observe significant emissions of X-ray sources. Flux profiles of the X-ray emission exhibit a progressively faster raise and decline as the higher energy channels are considered.

Keywords: magnetic reconnection, solar atmosphere, solar flare, X-ray emission

Procedia PDF Downloads 281