Search results for: invasive techniques
7318 Quality Assurance in Cardiac Disorder Detection Images
Authors: Anam Naveed, Asma Andleeb, Mehreen Sirshar
Abstract:
In the article, Image processing techniques have been applied on cardiac images for enhancing the image quality. Two types of methodologies considers for survey, invasive techniques and non-invasive techniques. Different image processes for improvement of cardiac image quality and reduce the amount of radiation exposure for invasive techniques are explored. Different image processing algorithms for enhancing the noninvasive cardiac image qualities are described. Beside these two methodologies, third methodology has applied on live streaming of heart rate on ECG window for extracting necessary information, removing noise and enhancing quality. Sensitivity analyses have been carried out to investigate the impacts of cardiac images for diagnosis of cardiac arteries disease and how the enhancement on images will help the cardiologist to diagnoses disease. The paper evaluates strengths and weaknesses of different techniques applied for improved the image quality and draw a conclusion. Some specific limitations must be considered for whole survey, like the patient heart beat must be 70-75 beats/minute while doing the angiography, similarly patient weight and exposure radiation amount has some limitation.Keywords: cardiac images, CT angiography, critical analysis, exposure radiation, invasive techniques, invasive techniques, non-invasive techniques
Procedia PDF Downloads 3517317 Brain-Computer Interfaces That Use Electroencephalography
Authors: Arda Ozkurt, Ozlem Bozkurt
Abstract:
Brain-computer interfaces (BCIs) are devices that output commands by interpreting the data collected from the brain. Electroencephalography (EEG) is a non-invasive method to measure the brain's electrical activity. Since it was invented by Hans Berger in 1929, it has led to many neurological discoveries and has become one of the essential components of non-invasive measuring methods. Despite the fact that it has a low spatial resolution -meaning it is able to detect when a group of neurons fires at the same time-, it is a non-invasive method, making it easy to use without possessing any risks. In EEG, electrodes are placed on the scalp, and the voltage difference between a minimum of two electrodes is recorded, which is then used to accomplish the intended task. The recordings of EEGs include, but are not limited to, the currents along dendrites from synapses to the soma, the action potentials along the axons connecting neurons, and the currents through the synaptic clefts connecting axons with dendrites. However, there are some sources of noise that may affect the reliability of the EEG signals as it is a non-invasive method. For instance, the noise from the EEG equipment, the leads, and the signals coming from the subject -such as the activity of the heart or muscle movements- affect the signals detected by the electrodes of the EEG. However, new techniques have been developed to differentiate between those signals and the intended ones. Furthermore, an EEG device is not enough to analyze the data from the brain to be used by the BCI implication. Because the EEG signal is very complex, to analyze it, artificial intelligence algorithms are required. These algorithms convert complex data into meaningful and useful information for neuroscientists to use the data to design BCI devices. Even though for neurological diseases which require highly precise data, invasive BCIs are needed; non-invasive BCIs - such as EEGs - are used in many cases to help disabled people's lives or even to ease people's lives by helping them with basic tasks. For example, EEG is used to detect before a seizure occurs in epilepsy patients, which can then prevent the seizure with the help of a BCI device. Overall, EEG is a commonly used non-invasive BCI technique that has helped develop BCIs and will continue to be used to detect data to ease people's lives as more BCI techniques will be developed in the future.Keywords: BCI, EEG, non-invasive, spatial resolution
Procedia PDF Downloads 717316 Non-Invasive Techniques for Management of Carious Primary Dentition Using Silver Diamine Fluoride and Moringa Extract as a Modification of the Hall Technique
Authors: Rasha F. Sharaf
Abstract:
Treatment of dental caries in young children is considered a great challenge for all dentists, especially with uncooperative children. Recently non-invasive techniques have been highlighted as they alleviate the need for local anesthesia and other painful procedures during management of carious teeth and, at the same time, increase the success rate of the treatment done. Silver Diamine Fluoride (SDF) is one of the most effective cariostatic materials that arrest the progression of carious lesions and aid in remineralizing the demineralized tooth structure. Both fluoride and silver ions proved to have an antibacterial action and aid in the precipitation of an insoluble layer that prevents further decay. At the same time, Moringa proved to have an effective antibacterial action against different types of bacteria, therefore, it can be used as a non-invasive technique for the management of caries in children. One of the important theories for the control of caries is by depriving the cariogenic bacteria from nutrients causing their starvation and death, which can be achieved by applying stainless steel crown on primary molars with carious lesions which are not involving the pulp, and this technique is known as Hall technique. The success rate of the Hall technique can be increased by arresting the carious lesion using either SDF or Moringa and gaining the benefit of their antibacterial action. Multiple clinical cases with 1 year follow up will be presented, comparing different treatment options, and using various materials and techniques for non-invasive and non-painful management of carious primary teeth.Keywords: SDF, hall technique, carious primary teeth, moringa extract
Procedia PDF Downloads 967315 Contactless Electromagnetic Detection of Stress Fluctuations in Steel Elements
Authors: M. A. García, J. Vinolas, A. Hernando
Abstract:
Steel is nowadays one of the most important structural materials because of its outstanding mechanical properties. Therefore, in order to look for a sustainable economic model and to optimize the use of extensive resources, new methods to monitor and prevent failure of steel-based facilities are required. The classical mechanical tests, as for instance building tasting, are invasive and destructive. Moreover, for facilities where the steel element is embedded, (as reinforced concrete) these techniques are directly non applicable. Hence, non-invasive monitoring techniques to prevent failure, without altering the structural properties of the elements are required. Among them, electromagnetic methods are particularly suitable for non-invasive inspection of the mechanical state of steel-based elements. The magnetoelastic coupling effects induce a modification of the electromagnetic properties of an element upon applied stress. Since most steels are ferromagnetic because of their large Fe content, it is possible to inspect their structure and state in a non-invasive way. We present here a distinct electromagnetic method for contactless evaluation of internal stress in steel-based elements. In particular, this method relies on measuring the magnetic induction between two coils with the steel specimen in between them. We found that the alteration of electromagnetic properties of the steel specimen induced by applied stress-induced changes in the induction allowed us to detect stress well below half of the elastic limit of the material. Hence, it represents an outstanding non-invasive method to prevent failure in steel-based facilities. We here describe the theoretical model, present experimental results to validate it and finally we show a practical application for detection of stress and inhomogeneities in train railways.Keywords: magnetoelastic, magnetic induction, mechanical stress, steel
Procedia PDF Downloads 497314 Assessing the Impacts of Frugivorous Birds on Dispersal and Recruitment of Invasive Phytolacca Americana in an Urban Landscape
Authors: Ning Li, Yaner Yan, Yajun Qiao, Shu-qing An
Abstract:
Although seed dispersal is considered to be a key process determining the spatial structure and spread of invasive plant populations, few studies have explicitly addressed the link between dispersal vector behaviour, and seedling recruitment to gain insight into the process of exotic species invasion within a urban landscape. The present study tests the effects of native bird species on the dispersal and recruitment of invasive Phytolacca Americana in an urban garden. We found the invasive population of American pokeweed attracted both generalist species and specialist species to forage and disperse its seeds, with generalists Pycnonotus sinensis and Urocissa erythrorhyncha being by far the most important dispersers. Seedling numbers of P. Americana was strongly affected by perching behavior of bird dispersers. Moreover, two main disperser species, P. sinensis and U. erythrorhyncha govern a high quality dispersal service for P. Americana. Our results highlight the ability of invasive P. americana to recruit seed dispersal agents in urban habitats. However, if the newly recruited species could use the seedling safe site for perching shelter, the invasive plants will get a high regenerate rate in the invasive new habitats thus enhancing their invasive ability.Keywords: frugivorous birds, phytolacca americana, seed dispersal, urban landscape
Procedia PDF Downloads 5437313 Blood Glucose Level Measurement from Breath Analysis
Authors: Tayyab Hassan, Talha Rehman, Qasim Abdul Aziz, Ahmad Salman
Abstract:
The constant monitoring of blood glucose level is necessary for maintaining health of patients and to alert medical specialists to take preemptive measures before the onset of any complication as a result of diabetes. The current clinical monitoring of blood glucose uses invasive methods repeatedly which are uncomfortable and may result in infections in diabetic patients. Several attempts have been made to develop non-invasive techniques for blood glucose measurement. In this regard, the existing methods are not reliable and are less accurate. Other approaches claiming high accuracy have not been tested on extended dataset, and thus, results are not statistically significant. It is a well-known fact that acetone concentration in breath has a direct relation with blood glucose level. In this paper, we have developed the first of its kind, reliable and high accuracy breath analyzer for non-invasive blood glucose measurement. The acetone concentration in breath was measured using MQ 138 sensor in the samples collected from local hospitals in Pakistan involving one hundred patients. The blood glucose levels of these patients are determined using conventional invasive clinical method. We propose a linear regression classifier that is trained to map breath acetone level to the collected blood glucose level achieving high accuracy.Keywords: blood glucose level, breath acetone concentration, diabetes, linear regression
Procedia PDF Downloads 1707312 Effect of Non-Invasive Electrical Stimulation on Partial Hearing Loss: Pilot Study
Authors: Geetanjali Saggar
Abstract:
Background: Partial hearing loss is the inability to hear effectively as a normal hearing individual whose hearing threshold is 20 dB or better in both ears. Individuals with partial hearing loss may benefit from non-invasive electrical stimulation as a method of therapy and possible intervention. Objective: The project aims to assess and relate the efficacy of electrical stimulation on individuals with partial hearing loss. The study's goal was to evaluate the different sorts of non-invasive electrical stimulation in tinnitus and hearing loss in order to build the framework for future research. Method: In this pilot study, a total of five patients of age group above 50 years were selected with partial hearing loss. The electrical modality of Repetitive Transcranial Magnetic Stimulation (RTMS) was used among the patients and was evaluated using gold questionnaires- HHIA and APHAB for hearing at intervals of 0-7-14 days. The statistical data was analyzed by SPSS software-16. Results: There were not much significant changes in the hearing of the patients when non-invasive electrical modality was applied as an intervention in the partial hearing loss condition. However, there was minimal change in the daily functioning of the patient with the application of intervention. Conclusion: This study concluded that non-invasive electrical stimulation had minimal to no effect on the partial hearing of the patients.Keywords: non-invasive, hearing loss, transcranial magnetic stimulation, partial deafness, transcranial direct current stimulation, tinnitus
Procedia PDF Downloads 117311 Factors Associated with Commencement of Non-Invasive Ventilation
Authors: Manoj Kumar Reddy Pulim, Lakshmi Muthukrishnan, Geetha Jayapathy, Radhika Raman
Abstract:
Introduction: In the past two decades, noninvasive positive pressure ventilation (NIPPV) emerged as one of the most important advances in the management of both acute and chronic respiratory failure in children. In the acute setting, it is an alternative to intubation with a goal to preserve normal physiologic functions, decrease airway injury, and prevent respiratory tract infections. There is a need to determine the clinical profile and parameters which point towards the need for NIV in the pediatric emergency setting. Objectives: i) To study the clinical profile of children who required non invasive ventilation and invasive ventilation, ii) To study the clinical parameters common to children who required non invasive ventilation. Methods: All children between one month to 18 years, who were intubated in the pediatric emergency department and those for whom decision to commence Non Invasive Ventilation was made in Emergency Room were included in the study. Children were transferred to the Paediatric Intensive Care Unit and started on Non Invasive Ventilation as per our hospital policy and followed up in the Paediatric Intensive Care Unit. Clinical profile of all children which included age, gender, diagnosis and indication for intubation were documented. Clinical parameters such as respiratory rate, heart rate, saturation, grunting were documented. Parameters obtained were subject to statistical analysis. Observations: Airway disease (Bronchiolitis 25%, Viral induced wheeze 22%) was a common diagnosis in 32 children who required Non Invasive Ventilation. Neuromuscular disorder was the common diagnosis in 27 children (78%) who were Intubated. 17 children commenced on Non Invasive Ventilation who later needed invasive ventilation had Neuromuscular disease. High frequency nasal cannula was used in 32, and mask ventilation in 17 children. Clinical parameters common to the Non Invasive Ventilation group were age < 1 year (17), tachycardia n = 7 (22%), tachypnea n = 23 (72%) and severe respiratory distress n = 9 (28%), grunt n = 7 (22%), SPO2 (80% to 90%) n = 16. Children in the Non Invasive Ventilation + INTUBATION group were > 3 years (9), had tachycardia 7 (41%), tachypnea 9(53%) with a male predominance n = 9. In statistical comparison among 3 groups,'p' value was significant for pH, saturation, and use of Ionotrope. Conclusion: Invasive ventilation can be avoided in the paediatric Emergency Department in children with airway disease, by commencing Non Invasive Ventilation early. Intubation in the pediatric emergency department has a higher association with neuromuscular disorders.Keywords: clinical parameters, indications, non invasive ventilation, paediatric emergency room
Procedia PDF Downloads 3367310 Placenta Parenchymal Dysplasia: When to Depend on Color Doppler and MRI
Authors: Bernard Olumide Ewuoso, Asma Gharaibeh
Abstract:
Rationale: Placental mesenchymal dysplasia (PMD) resembles molar pregnancy quite a bit. Although there have been documented live births of healthy babies, obtaining an objective diagnosis is crucial to assisting the mother in making an educated decision on what option of management she would like to explore. Prenatal invasive testing is recommended to help obtain an objective diagnosis in cases of abnormal placenta. We present a 23-year-old who, at 14 weeks, had ultrasonographic findings suggestive of placental mesenchymal dysplasia. She was offered prenatal invasive testing but declined and opted for surgical management, with a diagnosis of PMD confirmed on histopathology. There will be occasions such as this when prenatal invasive testing is declined. In these situations, careful consideration can be given to color Doppler and MRI, especially if the patient decides to keep pregnancy.Keywords: placental mesenchymal dysplasisa, molar pregnancy, prenatal invasive testing, Color doppler, MRI
Procedia PDF Downloads 237309 A Novel Method For Non-Invasive Diagnosis Of Hepatitis C Virus Using Electromagnetic Signal Detection: A Multicenter International Study
Authors: Gamal Shiha, Waleed Samir, Zahid Azam, Premashis Kar, Saeed Hamid, Shiv Sarin
Abstract:
A simple, rapid and non-invasive electromagnetic sensor (C-FAST device) was- patented; for diagnosis of HCV RNA. Aim: To test the validity of the device compared to standard HCV PCR. Subjects and Methods: The first phase was done as pilot in Egypt on 79 participants; the second phase was done in five centers: one center from Egypt, two centers from Pakistan and two centers from India (800, 92 and 113 subjects respectively). The third phase was done nationally as multicenter study on (1600) participants for ensuring its representativeness. Results: When compared to PCR technique, C-FAST device revealed sensitivity 95% to 100%, specificity 95.5% to 100%, PPV 89.5% to 100%, NPV 95% to 100% and positive likelihood ratios 21.8% to 38.5%. Conclusion: It is practical evidence that HCV nucleotides emit electromagnetic signals that can be used for its identification. As compared to PCR, C-FAST is an accurate, valid and non-invasive device.Keywords: C-FAST- a valid and reliable device, distant cellular interaction, electromagnetic signal detection, non-invasive diagnosis of HCV
Procedia PDF Downloads 4317308 Advanced Techniques in Robotic Mitral Valve Repair
Authors: Abraham J. Rizkalla, Tristan D. Yan
Abstract:
Purpose: Durable mitral valve repair is preferred to a replacement, avoiding the need for anticoagulation or re-intervention, with a reduced risk of endocarditis. Robotic mitral repair has been gaining favour globally as a safe, effective, and reproducible method of minimally invasive valve repair. In this work, we showcase the use of the Davinci© Xi robotic platform to perform several advanced techniques, working synergistically to achieve successful mitral repair in advanced mitral disease. Techniques: We present the case of a Barlow type mitral valve disease with a tall and redundant posterior leaflet resulting in severe mitral regurgitation and systolic anterior motion. Firstly, quadrangular resection of P2 is performed to remove the excess and redundant leaflet. Secondly, a sliding leaflet plasty of P1 and P3 is used to reconstruct the posterior leaflet. To anchor the newly formed posterior leaflet to the papillary muscle, CV-4 Goretex neochordae are fashioned using the innovative string, ruler, and bulldog technique. Finally, mitral valve annuloplasty and closure of a patent foramen ovale complete the repair. Results: There was no significant residual mitral regurgitation and complete resolution of the systolic anterior motion of the mitral valve on post operative transoesophageal echocardiography. Conclusion: This work highlights the robotic approach to complex repair techniques for advanced mitral valve disease. Familiarity with resection and sliding plasty, neochord implantation, and annuloplasty allows the modern cardiac surgeon to achieve a minimally-invasive and durable mitral valve repair when faced with complex mitral valve pathology.Keywords: robotic mitral valve repair, Barlow's valve, sliding plasty, neochord, annuloplasty, quadrangular resection
Procedia PDF Downloads 857307 Non-Invasive Techniques of Analysis of Painting in Forensic Fields
Authors: Radka Sefcu, Vaclava Antuskova, Ivana Turkova
Abstract:
A growing market with modern artworks of a high price leads to the creation and selling of artwork counterfeits. Material analysis is an important part of the process of assessment of authenticity. Knowledge of materials and techniques used by original authors is also necessary. The contribution presents possibilities of non-invasive methods of structural analysis in research on paintings. It was proved that unambiguous identification of many art materials is feasible without sampling. The combination of Raman spectroscopy with FTIR-external reflection enabled the identification of pigments and binders on selected artworks of prominent Czech painters from the first half of the 20th century – Josef Čapek, Emil Filla, Václav Špála and Jan Zrzavý. Raman spectroscopy confirmed the presence of a wide range of white pigments - lead white, zinc white, titanium white, barium white and also Freeman's white as a special white pigment of painting. Good results were obtained for red, blue and most of the yellow areas. Identification of green pigments was often impossible due to strong fluorescence. Oil was confirmed as a binding medium on most of the analyzed artworks via FTIR - external reflection. Collected data present the valuable background for the determination of art materials characteristic for each painter (his palette) and its development over time. Obtained results will further serve as comparative material for the authentication of artworks. This work has been financially supported by the project of the Ministry of the Interior of the Czech Republic: The Development of a Strategic Cluster for Effective Instrumental Technological Methods of Forensic Authentication of Modern Artworks (VJ01010004).Keywords: non-invasive analysis, Raman spectroscopy, FTIR-external reflection, forgeries
Procedia PDF Downloads 1717306 Cryptic Diversity: Identifying Two Morphologically Similar Species of Invasive Apple Snails in Peninsular Malaysia
Authors: Suganiya Rama Rao, Yoon-Yen Yow, Thor-Seng Liew, Shyamala Ratnayeke
Abstract:
Invasive snails in the genus Pomacea have spread across Southeast Asia including Peninsular Malaysia. Apart from significant economic costs to wetland crops, very little is known about the snails’ effects on native species, and wetland function through their alteration of macrophyte communities. This study was conducted to establish diagnostic characteristics of Pomacea species in the Malaysian environment using genetic and morphological criteria. Snails were collected from eight localities in northern and central regions of Peninsular Malaysia. The mitochondrial COI gene of 52 adult snails was amplified and sequenced. Maximum likelihood analysis was used to analyse species identity and assess phylogenetic relationships among snails from different geographic locations. Shells of the two species were compared using geometric morphometric analysis and covariance analyses. Shell height accounted for most of the observed variation between P. canaliculata and P. maculata, with the latter possessing a smaller mean ratio of shell height: aperture height (p < 0.0001) and shell height to shell width (give p < 0.0001). Genomic and phylogenetic analysis demonstrated the presence of two monophyletic taxa, P. canaliculata and P. maculata, in Peninsular Malaysia samples. P. maculata co-occurred with P. canaliculata in 5 localities, but samples from 3 localities contained only P. canaliculata. This study is the first to confirm the presence of two of the most invasive species of Pomacea in Peninsular Malaysia using a genomic approach. P. canaliculata appears to be the more widespread species. Despite statistical differences, both quantitative and qualitative morphological characteristics demonstrate much interspecific overlap and intraspecific variability; thus morphology alone cannot reliably verify species identity. Molecular techniques for distinguishing between these two highly invasive Pomacea species are needed to understand their specific ecological niches and develop effective protocols for their management.Keywords: Pomacea canaliculata, Pomacea maculata, invasive species, phylog enetic analysis, geometric morphometric analysis
Procedia PDF Downloads 2637305 Comparative Study Between Oral and Intralesional Injection of Beta Blocker in the Treatment of Infantile Capillary Hemangioma
Authors: Nadeen Eltoukhy, Sahar S. Sheta, Walaa Elnaggar, Karim Bakr
Abstract:
Purpose: The aim of this study is to compare the clinical efficacy and side effects of oral versus intralesional propranolol treatment of infantile capillary hemangiomas in infants. Methods: The study enrolled 40 infants diagnosed with infantile capillary hemangiomas. Patients were divided into 2 groups: Group A (Non-invasive group) included 20 infants who received oral propranolol hydrochloride starting at a dose of 1 mg/kg/day BID, then increased to a max of 2 mg/kg/day BID gradually over 2 weeks for 3 months. Group B (Invasive group) included 20 infants who received intralesional propranolol injection at a dose of 1 mg/mL; the volume of the injected drug depended on the size of the lesion (0.2 mL injected per cm of lesion diameter), with a maximum volume of 1 mL for a lesion of 5 cm diameter under complete aseptic conditions in the operating theater. Results: At three months after initiating treatment, the circumferential size of the hemangioma showed a statistically significant decrease in both groups; in Group A from 3.66±2.89 cm to 1.56±1.26 cm with p-value <0.05 and in Group B from 2.99±2.73 cm to 1.32±1.18 cm with p-value <0.05. There is no statistically significant comparative difference between the two groups (p-value = 0.538 = insignificant). Regarding the complications of oral propranolol, one patient (5%) had bradycardia, and one patient (5%) had diarrhea. In the injection group, 20 patients (100%) had local edema, and one patient (5%) had a local infection. Conclusions: Both oral non-invasive and intralesional invasive propranolol are safely used to successfully treat and decrease the size of infantile hemangioma while showing no statistically comparative difference between both treatment techniques.Keywords: hemangioma, oral beta blocker, intralesional beta blocker, infants
Procedia PDF Downloads 527304 Comparative Study on Efficacy and Clinical Outcomes in Minimally Invasive Surgery Transforaminal Interbody Fusion vs Minimally Invasive Surgery Lateral Interbody Fusion
Authors: Sundaresan Soundararajan, George Ezekiel Silvananthan, Chor Ngee Tan
Abstract:
Introduction: Transforaminal Interbody Fusion (TLIF) has been adopted for many decades now, however, XLIF, still in relative infancy, has grown to be accepted as a new Minimally Invasive Surgery (MIS) option. There is a paucity of reports directly comparing lateral approach surgery to other MIS options such as TLIF in the treatment of lumbar degenerative disc diseases. Aims/Objectives: The objective of this study was to compare the efficacy and clinical outcomes between Minimally Invasive Transforaminal Interbody Fusion (TLIF) and Minimally Invasive Lateral Interbody Fusion (XLIF) in the treatment of patients with degenerative disc disease of the lumbar spine. Methods: A single center, retrospective cohort study involving a total of 38 patients undergoing surgical intervention between 2010 and 2013 for degenerative disc disease of lumbar spine at single L4/L5 level. 18 patients were treated with MIS TLIF, and 20 patients were treated with XLIF. Results: The XLIF group showed shorter duration of surgery compared to the TLIF group (176 mins vs. 208.3 mins, P = 0.03). Length of hospital stay was also significantly shorter in XLIF group (5.9 days vs. 9 days, p = 0.03). Intraoperative blood loss was favouring XLIF as 85% patients had blood loss less than 100cc compared to 58% in the TLIF group (P = 0.03). Radiologically, disc height was significantly improved post operatively in the XLIF group compared to the TLIF group (0.56mm vs. 0.39mm, P = 0.01). Foraminal height increment was also higher in the XLIF group (0.58mm vs. 0.45mm , P = 0.06). Clinically, back pain and leg pain improved in 85% of patients in the XLIF group and 78% in the TLIF group. Post op hip flexion weakness was more common in the XLIF group (40%) than in the TLIF group (0%). However, this weakness resolved within 6 months post operatively. There was one case of dural tear and surgical site infection in the TLIF group respectively and none in the XLIF group. Visual Analog Scale (VAS) score 6 months post operatively showed comparable reduction in both groups. TLIF group had Owsterty Disability Index (ODI) improvement on 67% while XLIF group showed improvement of 70% of its patients. Conclusions: Lateral approach surgery shows comparable clinical outcomes in resolution of back pain and radiculopathy to conventional MIS techniques such as TLIF. With significantly shorter duration of surgical time, minimal blood loss and shorter hospital stay, XLIF seems to be a reasonable MIS option compared to other MIS techniques in treating degenerative lumbar disc diseases.Keywords: extreme lateral interbody fusion, lateral approach, minimally invasive, XLIF
Procedia PDF Downloads 2187303 Nanomaterials Based Biosensing Chip for Non-Invasive Detection of Oral Cancer
Authors: Suveen Kumar
Abstract:
Oral cancer (OC) is the sixth most death causing cancer in world which includes tumour of lips, floor of the mouth, tongue, palate, cheeks, sinuses, throat, etc. Conventionally, the techniques used for OC detection are toluidine blue staining, biopsy, liquid-based cytology, visual attachments, etc., however these are limited by their highly invasive nature, low sensitivity, time consumption, sophisticated instrument handling, sample processing and high cost. Therefore, we developed biosensing chips for non-invasive detection of OC via CYFRA-21-1 biomarker. CYFRA-21-1 (molecular weight: 40 kDa) is secreted in saliva of OC patients which is a non-invasive biological fluid with a cut-off value of 3.8 ng mL-1, above which the subjects will be suffering from oral cancer. Therefore, in first work, 3-aminopropyl triethoxy silane (APTES) functionalized zirconia (ZrO2) nanoparticles (APTES/nZrO2) were used to successfully detect CYFRA-21-1 in a linear detection range (LDR) of 2-16 ng mL-1 with sensitivity of 2.2 µA mL ng-1. Successively, APTES/nZrO2-RGO was employed to prevent agglomeration of ZrO2 by providing high surface area reduced graphene oxide (RGO) support and much wider LDR (2-22 ng mL-1) was obtained with remarkable limit of detection (LOD) as 0.12 ng mL-1. Further, APTES/nY2O3/ITO platform was used for oral cancer bioseneor development. The developed biosensor (BSA/anti-CYFRA-21-1/APTES/nY2O3/ITO) have wider LDR (0.01-50 ng mL-1) with remarkable limit of detection (LOD) as 0.01 ng mL-1. To improve the sensitivity of the biosensing platform, nanocomposite of yattria stabilized nanostructured zirconia-reduced graphene oxide (nYZR) based biosensor has been developed. The developed biosensing chip having ability to detect CYFRA-21-1 biomolecules in the range of 0.01-50 ng mL-1, LOD of 7.2 pg mL-1 with sensitivity of 200 µA mL ng-1. Further, the applicability of the fabricated biosensing chips were also checked through real sample (saliva) analysis of OC patients and the obtained results showed good correlation with the standard protein detection enzyme linked immunosorbent assay (ELISA) technique.Keywords: non-invasive, oral cancer, nanomaterials, biosensor, biochip
Procedia PDF Downloads 1267302 Microplastic Accumulation in Native and Invasive Sea Urchin Populations on Lipsi Island (Aegean Sea)
Authors: Ella Zahra
Abstract:
Sea urchins are keystone species in many global benthic ecosystems. The concentration of microplastics (MPs) in sea urchin organs was quantified in 120 individuals of 2 different species and from 4 sites across the Greek island Lipsi, with special interest in the differences between the native Arbacia lixula and the invasive Diadema setosum. Over 93% of MPs observed in both species were fibrous. MP abundance was found to correlate with exposure to open sea and harsh prevailing winds, irrespective of proximity to urban activities. The MP abundance in the invasive species was not found to be significantly dependent on site. Interestingly, the smaller native species contained significantly larger sized MPs than the invasive, possibly as a result of a greater feeding rate in A. lixula individuals. Sexually immature urchins may also have a higher feeding rate, giving rise to the negative correlation between gonad index and MPs per individual. The size of MPs ranged from 10µm to 24210µm, heavily skewed towards smaller particles. Few differences in colour were noted between the species and sites. MPs were detected in 100% of the samples with abundance ranging from 19.27 ± 6.77 to 26.83 ± 8.15 items per individual, or 3.55 ± 3.73 to 7.34 ± 10.51 items per gram of wet organ weight. This high value could lead to health risks in East Asia and the Mediterranean, where sea urchin is widely consumed, due to toxins adsorbed to the MPs.Keywords: microplastics, plastic pollution, invertebrate ecology, invasive marine species
Procedia PDF Downloads 1067301 Assessment of the Possible Effects of Biological Control Agents of Lantana camara and Chromolaena odorata in Davao City, Mindanao, Philippines
Authors: Cristine P. Canlas, Crislene Mae L. Gever, Patricia Bea R. Rosialda, Ma. Nina Regina M. Quibod, Perry Archival C. Buenavente, Normandy M. Barbecho, Cynthia Adeline A. Layusa, Michael Day
Abstract:
Invasive plants have an impact on global biodiversity and ecosystem function, and their management is a complex and formidable task. Two of these invasive plant species, Lantana camara and Chromolaena odorata, are found in the Philippines. Lantana camara has the ability to suppress the growth of and outcompete neighboring plants. Chromolaena odorata causes serious agricultural and economical damage and causes fire hazards during dry season. In addition, both species has been reported to poison livestock. One of the known global management strategies to control invasive plants is the introduction of biological control agents. These natural enemies of the invasive plants reduce population density and impacts of the invasive plants, resulting in the balance of the nature in their invasion. Through secondary data sources, interviews, and field validation (e.g. microhabitat searches, sweep netting, opportunistic sampling, photo-documentation), we investigated whether the biocontrol agents previously released by the Philippine Coconut Authority (PCA) in their Davao Research Center to control these invasive plants are still present and are affecting their respective host weeds. We confirm the presence of the biocontrol agent of L. camara, Uroplata girardi, which was introduced in 1985, and Cecidochares connexa, a biocontrol agent of C. odorata released in 2003. Four other biocontrol agents were found to affect L. camara. Signs of damage (e.g. stem galls in C. odorata, and leaf mines in L. camara) signify that these biocontrol agents have successfully established outside of their release site in Davao. Further investigating the extent of the spread of these biocontrol agents in the Philippines and their damage to the two weeds will contribute to the management of invasive plant species in the country.Keywords: invasive alien species, biological control agent, entomology, worst weeds
Procedia PDF Downloads 3747300 Minimal Invasive Esophagectomy for Esophageal Cancer: An Institutional Review From a Dedicated Centre of Pakistan
Authors: Nighat Bakhtiar, Ali Raza Khan, Shahid Khan Khattak, Aamir Ali Syed
Abstract:
Introduction: Chemoradiation followed by resection has been the standard therapy for resectable (cT1-4aN0-3M0) esophageal carcinoma. The optimal surgical approach remains a matter of debate. Therefore, the purpose of this study was to share our experiences of minimal invasive esophagectomies concerning morbidity, mortality and oncological quality. This study aims to enlighten the world about the surgical outcomes after minimally invasive esophagectomy at Shaukat Khanum Hospital Lahore. Objective: The purpose of this study is to review an institutional experience of Surgical outcomes of Minimal Invasive esophagectomies for esophageal cancer. Methodology: This retrospective study was performed after ethical approval at Shaukat Khanum Memorial Cancer Hospital and Research Centre (SKMCH&RC) Pakistan. Patients who underwent Minimal Invasive esophagectomies for esophageal cancer from March 2018 to March 2023 were selected. Data was collected through the human information system (HIS) electronic database of SKMCH&RC. Data was described using mean and median with minimum and maximum values for quantitative variables. For categorical variables, a number of observations and percentages were reported. Results: A total of 621 patients were included in the study, with the mean age of the patient was 39 years, ranging between 18-58 years. Mean Body Mass Index of patients was 21.2.1±4.1. Neo-adjuvant chemoradiotherapy was given to all patients. The mean operative time was 210.36 ± 64.51 minutes, and the mean blood loss was 121 milliliters. There was one mortality in 90 days, while the mean postoperative hospital stay was 6.58 days with a 4.64 standard deviation. The anastomotic leak rate was 4.2%. Chyle leak was observed in 12 patients. Conclusion: The minimal invasive technique is a safe approach for esophageal cancers, with minimal complications and fast recovery.Keywords: minimal invasive, esophagectomy, laparscopic, cancer
Procedia PDF Downloads 737299 Minimally Invasive versus Conventional Sternotomy for Aortic Valve Replacement: A Systematic Review and Meta-Analysis
Authors: Ahmed Shaboub, Yusuf Jasim Althawadi, Shadi Alaa Abdelaal, Mohamed Hussein Abdalla, Hatem Amr Elzahaby, Mohamed Mohamed, Hazem S. Ghaith, Ahmed Negida
Abstract:
Objectives: We aimed to compare the safety and outcomes of the minimally invasive approaches versus conventional sternotomy procedures for aortic valve replacement. Methods: We conducted a PRISMA-compliant systematic review and meta-analysis. We ran an electronic search of PubMed, Cochrane CENTRAL, Scopus, and Web of Science to identify the relevant published studies. Data were extracted and pooled as standardized mean difference (SMD) or risk ratio (RR) using StataMP version 17 for macOS. Results: Forty-one studies with a total of 15,065 patients were included in this meta-analysis (minimally invasive approaches n=7231 vs. conventional sternotomy n=7834). The pooled effect size showed that minimally invasive approaches had lower mortality rate (RR 0.76, 95%CI [0.59 to 0.99]), intensive care unit and hospital stays (SMD -0.16 and -0.31, respectively), ventilation time (SMD -0.26, 95%CI [-0.38 to -0.15]), 24-h chest tube drainage (SMD -1.03, 95%CI [-1.53 to -0.53]), RBCs transfusion (RR 0.81, 95%CI [0.70 to 0.93]), wound infection (RR 0.66, 95%CI [0.47 to 0.92]) and acute renal failure (RR 0.65, 95%CI [0.46 to 0.93]). However, minimally invasive approaches had longer operative time, cross-clamp, and bypass times (SMD 0.47, 95%CI [0.22 to 0.72], SMD 0.27, 95%CI [0.07 to 0.48], and SMD 0.37, 95%CI [0.20 to 0.45], respectively). There were no differences between the two groups in blood loss, endocarditis, cardiac tamponade, stroke, arrhythmias, pneumonia, pneumothorax, bleeding reoperation, tracheostomy, hemodialysis, or myocardial infarction (all P>0.05). Conclusion: Current evidence showed higher safety and better operative outcomes with minimally invasive aortic valve replacement compared to the conventional approach. Future RCTs with long-term follow-ups are recommended.Keywords: aortic replacement, minimally invasive, sternotomy, mini-sternotomy, aortic valve, meta analysis
Procedia PDF Downloads 1207298 Linear Prediction System in Measuring Glucose Level in Blood
Authors: Intan Maisarah Abd Rahim, Herlina Abdul Rahim, Rashidah Ghazali
Abstract:
Diabetes is a medical condition that can lead to various diseases such as stroke, heart disease, blindness and obesity. In clinical practice, the concern of the diabetic patients towards the blood glucose examination is rather alarming as some of the individual describing it as something painful with pinprick and pinch. As for some patient with high level of glucose level, pricking the fingers multiple times a day with the conventional glucose meter for close monitoring can be tiresome, time consuming and painful. With these concerns, several non-invasive techniques were used by researchers in measuring the glucose level in blood, including ultrasonic sensor implementation, multisensory systems, absorbance of transmittance, bio-impedance, voltage intensity, and thermography. This paper is discussing the application of the near-infrared (NIR) spectroscopy as a non-invasive method in measuring the glucose level and the implementation of the linear system identification model in predicting the output data for the NIR measurement. In this study, the wavelengths considered are at the 1450 nm and 1950 nm. Both of these wavelengths showed the most reliable information on the glucose presence in blood. Then, the linear Autoregressive Moving Average Exogenous model (ARMAX) model with both un-regularized and regularized methods was implemented in predicting the output result for the NIR measurement in order to investigate the practicality of the linear system in this study. However, the result showed only 50.11% accuracy obtained from the system which is far from the satisfying results that should be obtained.Keywords: diabetes, glucose level, linear, near-infrared, non-invasive, prediction system
Procedia PDF Downloads 1577297 Design and Evaluation of a Prototype for Non-Invasive Screening of Diabetes – Skin Impedance Technique
Authors: Pavana Basavakumar, Devadas Bhat
Abstract:
Diabetes is a disease which often goes undiagnosed until its secondary effects are noticed. Early detection of the disease is necessary to avoid serious consequences which could lead to the death of the patient. Conventional invasive tests for screening of diabetes are mostly painful, time consuming and expensive. There’s also a risk of infection involved, therefore it is very essential to develop non-invasive methods to screen and estimate the level of blood glucose. Extensive research is going on with this perspective, involving various techniques that explore optical, electrical, chemical and thermal properties of the human body that directly or indirectly depend on the blood glucose concentration. Thus, non-invasive blood glucose monitoring has grown into a vast field of research. In this project, an attempt was made to device a prototype for screening of diabetes by measuring electrical impedance of the skin and building a model to predict a patient’s condition based on the measured impedance. The prototype developed, passes a negligible amount of constant current (0.5mA) across a subject’s index finger through tetra polar silver electrodes and measures output voltage across a wide range of frequencies (10 KHz – 4 MHz). The measured voltage is proportional to the impedance of the skin. The impedance was acquired in real-time for further analysis. Study was conducted on over 75 subjects with permission from the institutional ethics committee, along with impedance, subject’s blood glucose values were also noted, using conventional method. Nonlinear regression analysis was performed on the features extracted from the impedance data to obtain a model that predicts blood glucose values for a given set of features. When the predicted data was depicted on Clarke’s Error Grid, only 58% of the values predicted were clinically acceptable. Since the objective of the project was to screen diabetes and not actual estimation of blood glucose, the data was classified into three classes ‘NORMAL FASTING’,’NORMAL POSTPRANDIAL’ and ‘HIGH’ using linear Support Vector Machine (SVM). Classification accuracy obtained was 91.4%. The developed prototype was economical, fast and pain free. Thus, it can be used for mass screening of diabetes.Keywords: Clarke’s error grid, electrical impedance of skin, linear SVM, nonlinear regression, non-invasive blood glucose monitoring, screening device for diabetes
Procedia PDF Downloads 3247296 Non-Native and Invasive Fish Species in Poland
Authors: Tomasz Raczyński
Abstract:
Non-native and invasive species negatively transform ecosystems. Non-native fish species can displace native fish species through competition, predation, disrupting spawning, transforming ecosystems, or transmitting parasites. This influence is more and more noticeable in Poland and in the world. From December 2014 to October 2020, did catch of fishes by electrofishing method carried on 416 sites in various parts of Poland. Research was conducted in both running and stagnant freshwaters with the predominance of running waters. Only sites where the presence of fish was found were analysed. The research covered a wide spectrum of waters from small mountain streams, through drainage ditches to the largest Polish river - the Vistula. Single sites covered oxbow lakes, small ponds and lakes. Electrofishing was associated with ichthyofauna inventories and was mainly aimed at detecting protected species of fish and lampreys or included in the annexes to the EU Habitats Directive (Council Directive 92/43/EEC on the Conservation of natural habitats and of wild fauna and flora). The results of these catches were analysed for alien and invasive fish species. The analysis of the catch structure shows that in 71 out of 416 research sites was found alien and invasive fish species, belonging to 9 taxa. According to the above, alien species of fish are present in 17% of the study sites. The most frequently observed species was the Prussian carp Carassius gibelio, which was recorded on 43 sites. Stone moroko Pseudorasbora parva was found on 24 sites. Chinese sleeper Perccottus glenii was found on 6 sites, and Bullhead Ameiurus sp. was also found on 6 sites. Western tubenose goby Proterorhinus semilunaris was found at 5 sites and Rainbow trout Oncorhynchus mykiss at 3 sites. Monkey goby Neogobius fluviatilis, Round goby Neogobius melanostomus and Eurasian carp Cyprinus carpio was recorded on 2 sites.Keywords: non-native species, invasive species, fish species, invasive fish species, native fish species
Procedia PDF Downloads 1107295 Invasive Ranges of Gorse (Ulex europaeus) in South Australia and Sri Lanka Using Species Distribution Modelling
Authors: Champika S. Kariyawasam
Abstract:
The distribution of gorse (Ulex europaeus) plants in South Australia has been modelled using 126 presence-only location data as a function of seven climate parameters. The predicted range of U. europaeus is mainly along the Mount Lofty Ranges in the Adelaide Hills and on Kangaroo Island. Annual precipitation and yearly average aridity index appeared to be the highest contributing variables to the final model formulation. The Jackknife procedure was employed to identify the contribution of different variables to gorse model outputs and response curves were used to predict changes with changing environmental variables. Based on this analysis, it was revealed that the combined effect of one or more variables could make a completely different impact to the original variables on their own to the model prediction. This work also demonstrates the need for a careful approach when selecting environmental variables for projecting correlative models to climatically distinct area. Maxent acts as a robust model when projecting the fitted species distribution model to another area with changing climatic conditions, whereas the generalized linear model, bioclim, and domain models to be less robust in this regard. These findings are important not only for predicting and managing invasive alien gorse in South Australia and Sri Lanka but also in other countries of the invasive range.Keywords: invasive species, Maxent, species distribution modelling, Ulex europaeus
Procedia PDF Downloads 1337294 Thread Lift: Classification, Technique, and How to Approach to the Patient
Authors: Panprapa Yongtrakul, Punyaphat Sirithanabadeekul, Pakjira Siriphan
Abstract:
Background: The thread lift technique has become popular because it is less invasive, requires a shorter operation, less downtime, and results in fewer postoperative complications. The advantage of the technique is that the thread can be inserted under the skin without the need for long incisions. Currently, there are a lot of thread lift techniques with respect to the specific types of thread used on specific areas, such as the mid-face, lower face, or neck area. Objective: To review the thread lift technique for specific areas according to type of thread, patient selection, and how to match the most appropriate to the patient. Materials and Methods: A literature review technique was conducted by searching PubMed and MEDLINE, then compiled and summarized. Result: We have divided our protocols into two sections: Protocols for short suture, and protocols for long suture techniques. We also created 3D pictures for each technique to enhance understanding and application in a clinical setting. Conclusion: There are advantages and disadvantages to short suture and long suture techniques. The best outcome for each patient depends on appropriate patient selection and determining the most suitable technique for the defect and area of patient concern.Keywords: thread lift, thread lift method, thread lift technique, thread lift procedure, threading
Procedia PDF Downloads 2637293 Surgical Treatment of Glaucoma – Literature and Video Review of Blebs, Tubes, and Micro-Invasive Glaucoma Surgeries (MIGS)
Authors: Ana Miguel
Abstract:
Purpose: Glaucoma is the second cause of worldwide blindness and the first cause of irreversible blindness. Trabeculectomy, the standard glaucoma surgery, has a success rate between 36.0% and 98.0% at three years and a high complication rate, leading to the development of different surgeries, micro-invasive glaucoma surgeries (MIGS). MIGS devices are diverse and have various indications, risks, and effectiveness. We intended to review MIGS’ surgical techniques, indications, contra-indications, and IOP effect. Methods: We performed a literature review of MIGS to differentiate the devices and their reported effectiveness compared to traditional surgery (tubes and blebs). We also conducted a video review of the last 1000 glaucoma surgeries of the author (including MIGS, but also trabeculectomy, deep sclerectomy, and tubes of Ahmed and Baerveldt) performed at glaucoma and advanced anterior segment fellowship in Canada and France, to describe preferred surgical techniques for each. Results: We present the videos with surgical techniques and pearls for each surgery. Glaucoma surgeries included: 1- bleb surgery (namely trabeculectomy, with releasable sutures or with slip knots, deep sclerectomy, Ahmed valve, Baerveldt tube), 2- MIGS with bleb, also known as MIBS (including XEN 45, XEN 63, and Preserflo), 3- MIGS increasing supra-choroidal flow (iStar), 4-MIGS increasing trabecular flow (iStent, gonioscopy-assisted transluminal trabeculotomy - GATT, goniotomy, excimer laser trabeculostomy -ELT), and 5-MIGS decreasing aqueous humor production (endocyclophotocoagulation, ECP). There was also needling (ab interno and ab externo) performed at the operating room and irido-zonulo-hyaloïdectomy (IZHV). Each technique had different indications and contra-indications. Conclusion: MIGS are valuable in glaucoma surgery, such as traditional surgery with trabeculectomy and tubes. All glaucoma surgery can be combined with phacoemulsification (there may be a synergistic effect on MIGS + cataract surgery). In addition, some MIGS may be combined for further intraocular pressure lowering effect (for example, iStents with goniotomy and ECP). A good surgical technique and postoperative management are fundamental to increasing success and good practice in all glaucoma surgery.Keywords: glaucoma, migs, surgery, video, review
Procedia PDF Downloads 837292 Minimally Invasive Open Lumbar Discectomy with Nucleoplasty and Annuloplasty as a Technique for Effective Reduction of Both Axial and Radicular Pain
Authors: Wael Elkholy, Ashraf Sakr, Mahmoud Qandeel, Adam Elkholy
Abstract:
Lumbar disc herniation is a common pathology that may cause significant low back pain and radicular pain that could profoundly impair daily life activities of individuals. Patients who undergo surgical treatment for lumbar disc herniation usually present with radiculopathy along with low back pain (LBP) instead of radiculopathy alone. When discectomy is performed, improvement in leg radiating pain is observed due to spinal nerve irritation. However, long-term LBP due to degenerative changes in the disc may occur postoperatively. In addition, limited research has been reported on the short-term (within 1 year) improvement in LBP after discectomy. In this study we would like to share our minimally invasive open technique for lumbar discectomy with annuloplasty and nuceloplasty as a technique for effective reduction of both axial and radicular pain.Keywords: nucleoplasty, sinuvertebral nerve cauterization, annuloplasty, discogenic low back pain, axial pain, radicular pain, minimally invasive lumbar discectomy
Procedia PDF Downloads 677291 The OverStitch and OverStitch SX Endoscopic Suturing System in Bariatric Surgery, Closing Perforations and Fistulas and Revision Procedures
Authors: Mohammad Tayefeh Norooz, Amirhossein Kargarzadeh
Abstract:
Overweight and obesity as an abnormality are health threatening factors. Body mass index (BMI) above 25 is referred to as overweight and above 30 as obese. Apollo Endosurgery, Inc., a pioneering company in endoscopy surgeries, is poised to revolutionize patient care with its minimally invasive treatment options. Some product solutions are designed to improve patient outcomes and redefine the future of healthcare. Weight gain post-weight-loss surgery may stem from an enlarged stomach opening, reducing fullness and increasing food intake. Apollo Endosurgery's OverStitch system, a minimally invasive approach, addresses this by using sutures to reduce stomach opening size. This reflects Apollo's commitment to transformative improvements in healing endoscopy, emphasizing a shift towards minimally invasive options. The system's versatility and precision in full-thickness suturing offer treatment alternatives, exemplified in applications like Endoscopic Sleeve Gastroplasty for reshaping obesity management. Apollo’s dedication to pioneering advancements suggests ongoing breakthroughs in minimally invasive surgery, positioning the OverStitch systems as a testament to innovation in patient care.Keywords: apollo endosurgery, endoscopic sleeve gastroplasty, weight loss system, overstitch endoscopic suturing system, therapeutic, perforations, fistula
Procedia PDF Downloads 607290 An Efficient Design of Static Synchronous Series Compensator Based Fractional Order PID Controller Using Invasive Weed Optimization Algorithm
Authors: Abdelghani Choucha, Lakhdar Chaib, Salem Arif
Abstract:
This paper treated the problem of power system stability with the aid of Static Synchronous Series Compensator (SSSC) installed in the transmission line of single machine infinite bus (SMIB) power system. A fractional order PID (FOPID) controller has been applied as a robust controller for optimal SSSC design to control the power system characteristics. Additionally, the SSSC based FOPID parameters are smoothly tuned using Invasive Weed Optimization algorithm (IWO). To verify the strength of the proposed controller, SSSC based FOPID controller is validated in a wide range of operating condition and compared with the conventional scheme SSSC-POD controller. The main purpose of the proposed process is greatly enhanced the dynamic states of the tested system. Simulation results clearly prove the superiority and performance of the proposed controller design.Keywords: SSSC-FOPID, SSSC-POD, SMIB power system, invasive weed optimization algorithm
Procedia PDF Downloads 1887289 Non-Invasive Pre-Implantation Genetic Assessment Using NGS in IVF Clinical Routine
Authors: Katalin Gombos, Bence Gálik, Krisztina Ildikó Kalács, Krisztina Gödöny, Ákos Várnagy, József Bódis, Attila Gyenesei, Gábor L. Kovács
Abstract:
Although non-invasive pre-implantation genetic testing for aneuploidy (NIPGT-A) is potentially appropriate to assess chromosomal ploidy of the embryo, practical application of it in a routine IVF center has not been started in the absence of a recommendation. We developed a comprehensive workflow for a clinically applicable strategy for NIPGT-A based on next-generation sequencing (NGS) technology. We performed MALBAC whole genome amplification and NGS on spent blastocyst culture media of Day 3 embryos fertilized with intra-cytoplasmic sperm injection (ICSI). Spent embryonic culture media of morphologically good quality score embryos were enrolled in further analysis with the blank culture media as background control. Chromosomal abnormalities were identified by an optimized bioinformatics pipeline applying a copy number variation (CNV) detecting algorithm. We demonstrate a comprehensive workflow covering both wet- and dry-lab procedures supporting a clinically applicable strategy for NIPGT-A. It can be carried out within 48 h which is critical for the same-cycle blastocyst transfer, but also suitable for “freeze all” and “elective frozen embryo” strategies. The described integrated approach of non-invasive evaluation of embryonic DNA content of the culture media can potentially supplement existing pre-implantation genetic screening methods.Keywords: next generation sequencing, in vitro fertilization, embryo assessment, non-invasive pre-implantation genetic testing
Procedia PDF Downloads 155