Search results for: gymnastics conditioning
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 340

Search results for: gymnastics conditioning

340 Moved by Music: The Impact of Music on Fatigue, Arousal and Motivation During Conditioning for High to Elite Level Female Artistic Gymnasts

Authors: Chante J. De Klerk

Abstract:

The potential of music to facilitate superior performance during high to elite level gymnastics conditioning instigated this research. A team of seven gymnasts completed a fixed conditioning programme eight times, alternating the two variable conditions. Four sessions of each condition were conducted: without music (session 1), with music (session 2), without music (3), with music (4), without music (5), and so forth. Quantitative data were collected in both conditions through physiological monitoring of the gymnasts, and administration of the Situational Motivation Scale (SIMS). Statistical analysis of the physiological data made it possible to quantify the presence as well as the magnitude of the musical intervention’s impact on various aspects of the gymnasts' physiological functioning during conditioning. The SIMS questionnaire results were used to evaluate if their motivation towards conditioning was altered by the intervention. Thematic analysis of qualitative data collected through semi-structured interviews revealed themes reflecting the gymnasts’ sentiments towards the data collection process. Gymnast-specific descriptions and experiences of the team as a whole were integrated with the quantitative data to facilitate greater dimension in establishing the impact of the intervention. The results showed positive physiological, motivational, and emotional effects. In the presence of music, superior sympathetic nervous activation, and energy efficiency, with more economic breathing, dominated the physiological data. Fatigue and arousal levels (emotional and physiological) were also conducive to improved conditioning outcomes compared to conventional conditioning (without music). Greater levels of positive affect and motivation emerged in analysis of both the SIMS and interview data sets. Overall, the intervention was found to promote psychophysiological coherence during the physical activity. In conclusion, a strategically constructed musical intervention, designed to accompany a gymnastics conditioning session for high to elite level gymnasts, has ergogenic potential.

Keywords: arousal, fatigue, gymnastics conditioning, motivation, musical intervention, psychophysiological coherence

Procedia PDF Downloads 69
339 An Investigation into the Social Factors that Influence Sport Participation: A Case of Gymnastics in the Western Cape

Authors: W. C. Lucas, S. Titus, M. E. M. Young

Abstract:

Gymnastics is the umbrella term that represents seven different and unique disciplines of gymnastics. Men and women of all ages and abilities practice this sport, and participation in gymnastics can develop both gross and fine motor skills, strength, flexibility, coordination and balance. There are various social factors, such as a family’s socioeconomic status or accessibility to sports facilities that may play a role in affecting levels of participation. The aim of this study is to investigate the social factors that have an influence on gymnastics participation in the Western Cape. To this end, a qualitative approach is adopted to collect data. This study also adopts the ecological systems theory as the theoretical framework, and is used to analyze and interpret current social factors that directly or indirectly influence participation in gymnastics. The study’s objectives were to ascertain which social factors hinder participation, and which social factors promote participation, thus, coaches, parents and gymnasts participated in focus group discussions. Key informant interviews took place with experts in the field of gymnastics in the Western Cape. A thematic analysis was conducted on transcriptions from the focus group discussions and key informant interviews. Social factors investigated in this study occurred in the chronosystem, macrosystem, exosystem, mesosystem, and microsystem, and had both a direct and indirect influence on the gymnast’s continued participation. These systems are defined as the environment of the individual, in which they grow and develop. The research findings of this paper are used to draw conclusions and make specific recommendations for practice and further research. The information gathered in this study can assist all stakeholders within the field of gymnastics, such as parents, judges, coaches, gymnasts, and the supporting community which surround the participating gymnast.

Keywords: developing child, ecological systems theory, facilities, federation, gymnastics, influence, participation, social factors, socioeconomic status, sport

Procedia PDF Downloads 269
338 Association of Laterality and Sports Specific Rotational Preference with Number of Injuries in Artistic Gymnasts

Authors: Teja Joshi

Abstract:

Laterality has shown to play a role in performance as well as injuries especially in unilateral sports disciplines. Uniquely, Artistic Gymnastics involves combination of unilateral, bilateral and complex multi-planer elements as well as gymnastics specific rotational preference. Therefore, this study was conducted to explore if any such preferences are associated with number of injuries in artistic gymnasts. To explore the association between lateral preferences, rotational preferences and injuries incidence in artistic gymnastics. Artistic gymnasts above 16 years of age, were invited to participate in an online survey. The survey included consent, lateral preference inventory, injury data collection according to anatomical locations and rotational preference for selected gymnastics elements performed on the floor exercise. SPSS version 24 was used to analyse Non-parametric data using Kruskal-Wallis (K- independent test) test. Multiple regression was performed to identify the predictor for injuries and their side in gymnasts. Total number of injuries per gymnast was associated with handedness (p value-0.049) and no significant association was noted for footdness (p value-0.207), eyedness (p value-0.491) and eardness (p value-0.798). Additionally, rotational preferences did not influence number of injuries (p value-0.521). In multiple regression, eyedness was identified as a predicting factor to determine the number of injuries. Rotational preferences were neither determined as a national strategy nor a product of lateral preference. Dominant hand had higher number of injuries in artistic gymnasts. Rotational preference is independent of laterality, number of injuries and nationality.

Keywords: sports injury, rotational preference, gymnastics, handedness

Procedia PDF Downloads 85
337 The Comparison of Dismount Skill between National and International Men’s Artistic Gymnastics in Parallel Bars Apparatus

Authors: Chen ChihYu, Tang Wen Tzu, Chen Kuang Hui

Abstract:

Aim —To compare the dismount skill between Taiwanese and elite international gymnastics in parallel bars following the 2017-2020 code of points. Methods—The gymnasts who advanced to the parallel bars event finals of these four competitions including World Championships, Universiade, the National Games of Taiwan, and the National Intercollegiate Athletic Games of Taiwan both 2017 and 2019 were selected in this study. The dismount skill of parallel bars was analyzed, and the average difficulty score was compared by one-way ANOVA. Descriptive statistics were applied to present the type of dismount skill and the difficulty of each gymnast in these four competitions. The data from World Championships and Universiade were combined as the international group (INT), and data of Taiwanese National Games and National Intercollegiate Athletic Games were also combined as the national group (NAT). The differences between INT and NAT were analyzed by the Chi-square test. The statistical significance of this study was set at α= 0.05. Results— i) There was a significant difference in the mean parallel bars dismount skill in these four competitions analyzed by one-way ANOVA. Both dismount scores of World Championships and Universiade were significantly higher than in Taiwanese National Games and National Intercollegiate Athletic Games (0.58±0.08 & 0.56±0.08 > 0.42±0.06 & 40±0.06, p < 0.05). ii) Most of the gymnasts in World Championships and Universiade selected the 0.6-point skill as the parallel bars dismount element, and for the Taiwanese National Games and the National Intercollegiate Athletic Games, most of the gymnasts performed the 0.4-point dismount skill. iii) The result of the Chi-square test has shown that there was a significant difference in the selection of parallel bars dismount skill. The INT group used the E or E+ difficulty element as the dismount skill, and the NAT group selected the D or D- difficulty element. Conclusion— The level of parallel bars dismount in Taiwanese gymnastics is inferior to elite international gymnastics. It is suggested that Taiwanese gymnastics must try to practice the F difficulty dismount (double salto forward tucked with half twist) in the future.

Keywords: Artistic Gymnastics World Championships, dismount, difficulty score, element

Procedia PDF Downloads 116
336 The Classical Conditioning Effect of Animated Spokes-Characters

Authors: Chia-Ching Tsai, Ting-Hsiu Chen

Abstract:

This paper adopted 2X2 factorial design. One factor was experimental versus control condition. The other factor was types of animated spokescharacter, and one of the two levels was expert type, and the other level is attractive type. In the study, we use control versus experimental conditioning and types of animated spokescharacter as independent variables, and brand attitude as dependent variable to examine the conditioning effect of types of animated spokescharacter on brand attitude. There are 123 subjects participating in the experiment. The results showed conditioning group presents that animated spokescharacter has significantly superior effect of product endorsement in contrast to non-conditioning one, while there is no significant impact of types of animated spokescharacter on brand attitude.

Keywords: classical conditioning, animated spokes-character, brand attitude, factorial design

Procedia PDF Downloads 248
335 Design and Simulation of Variable Air Volume Air Conditioning System Based on Improved Sliding Mode Control

Authors: Abbas Anser, Ahmad Irfan

Abstract:

The main purpose of the VAV (Variable Air Volume) in Heating, Ventilation, and Air Conditioning (HVAC) system is to reduce energy consumption and make the buildings comfortable for the occupants. For better performance of the air conditioning system, different control techniques have been developed. In this paper, an Improved Sliding Mode Control (ISMC), based on Power Rate Exponential Reaching Law (PRERL), has been implemented on a VAV air conditioning system. Through the proposed technique, fast response and robustness have been achieved. To verify the efficacy of ISMC, a comparison of the suggested control technique has been made with Exponential Reaching Law (ERL) based SMC. And secondly, chattering, which is unfavorable as it deteriorates the mechanical parts of the air conditioning system by the continuous movement of the mechanical parts and consequently it increases the energy loss in the air conditioning system, has been alleviated. MATLAB/SIMULINK results show the effectiveness of the utilized scheme, which ensures the enhancement of the energy efficiency of the VAV air conditioning system.

Keywords: PID, SMC, HVAC, PRERL, feedback linearization, VAV, chattering

Procedia PDF Downloads 99
334 The Control Illusion of Conditioned Superstition

Authors: Chia-Ching Tsai

Abstract:

The study examined the control illusion of conditioned superstition by using Taiwanese subjects. The study had a three-group experimental design, that is, conditioning group and a control group, and the conditioning group was further separated into superstitious and unsuperstitious groups. The results showed that conditioned superstition can significantly influence the control illusion. Further analysis showed that the control illusion in the superstitious conditioning group was significantly greater than in the control group or in the unsuperstitious conditioning group. Besides, there was no significant difference between the control group and the unsuperstitious conditioning group.

Keywords: Control illusion, Conditioned superstition, experimental design

Procedia PDF Downloads 584
333 The Influence of Moisture Conditioning on Hamburg Wheel Tracking Test Results

Authors: Hussain Al-Baghli

Abstract:

The Hamburg Wheel Tracking Test (HWTT) was conducted to evaluate the resistance to moisture damage of two asphalt mixtures: an optimized rubberized asphalt mixture and an HMA mix with anti-stripping additives. The mixtures were subjected to varying numbers of moisture conditioning cycles and then tested for rutting depth. The results showed that the optimized rubberized asphalt mixture met the requirements for medium to heavy traffic in accordance with Kuwait's Ministry of Public Works specification. The number of moisture conditioning cycles did not significantly impact rutting development for the rubberized asphalt. The HMA asphalt samples showed a significant reduction in strength and did not satisfy the HWTT criteria after the moisture conditioning cycles.

Keywords: rubberized asphalt, Hamburg wheel tracking, antistripping, moisture conditioning

Procedia PDF Downloads 41
332 Tensile Strength of Asphalt Concrete Due to Moisture Conditioning

Authors: R. Islam, Rafiqul A. Tarefder

Abstract:

This study investigates the effect of moisture conditioning on the Indirect Tensile Strength (ITS) of asphalt concrete. As a first step, cylindrical samples of 100 mm diameter and 50 mm thick were prepared using a Superpave gyratory compactor. Next, the samples were conditioned using Moisture Induced Susceptibility Test (MIST) device at different numbers of moisture conditioning cycles. In the MIST device, samples are subjected water pressure through the sample pores cyclically. The MIST conditioned samples were tested for ITS. Results show that the ITS does not change significantly with MIST conditioning at the specific pressure and cycles adopted in this study.

Keywords: asphalt concrete, tensile strength, moisture, laboratory test

Procedia PDF Downloads 356
331 Gymnastics-Oriented Training Program: Impact of 6 weeks Training on the Fitness and Performance of Basketball Players

Authors: Syed Ibrahim, Syed Muneer Ahmed

Abstract:

It is a global phenomenon that fitness is a pre-requisite to the desired end of optimum efficiency in elite class basketballers achieved through appropriate conditioning program. This study was undertaken to find out the effect of gymnastic oriented training program on the physical fitness and the level of technical performance of basketball players. Method: 27 basketballers were divided into 12 experimental and 15 control groups aged between 19 to 25 years. Physical fitness tests comprising of vertical jump, push-ups, chin ups, sit ups, back strength, 30 m sprint, boomerangs test, 600 m run, sit and reach, bridge up and shoulder rotation and technical skill tests like dribbling, layup shots and rebound collection were used for the study. A pre- and post-test was conducted before and after the training program of 6 weeks. Results: The results indicated no significant difference in the anthropometric measurements of age, height and weight between the experimental and control group as the ‘t’ values observed were 0.28, 1.63 and 1.60 respectively . There were significant improvements in vertical jump, push-ups, sit-ups, modified boomerang test, bridge test and shoulder rotation index with the ‘t’ values being 2.60, 3.41, 3.91, 4.02, 3.55 and 2.33 respectively. However, no significant differences existed in chin-ups, back strength, 30 m sprint and 6000 m run with the ‘t’ values being 2.08, 1.77, 1.28 and 0.80 respectively. There was significant improvement in the post-test for the technical skills tests in the experimental group with ‘t’ values being 3.65, 2.57, and 3.62 for the dribble, layup shots and rebound collection respectively. There was no significant difference in the values of the control group except in the rebound collection which showed significant difference. Conclusion: It was found that both the physical fitness and skill proficiency of the basketballers increased through the participation in the gymnastics oriented program.

Keywords: gymnastic, technical, pre-requisite, elite class

Procedia PDF Downloads 374
330 Adsorptive Waste Heat Based Air-Conditioning Control Strategy for Automotives

Authors: Indrasen Raghupatruni, Michael Glora, Ralf Diekmann, Thomas Demmer

Abstract:

As the trend in automotive technology is fast moving towards hybridization and electrification to curb emissions as well as to improve the fuel efficiency, air-conditioning systems in passenger cars have not caught up with this trend and still remain as the major energy consumers amongst others. Adsorption based air-conditioning systems, e.g. with silica-gel water pair, which are already in use for residential and commercial applications, are now being considered as a technology leap once proven feasible for the passenger cars. In this paper we discuss a methodology, challenges and feasibility of implementing an adsorption based air-conditioning system in a passenger car utilizing the exhaust waste heat. We also propose an optimized control strategy with interfaces to the engine control unit of the vehicle for operating this system with reasonable efficiency supported by our simulation and validation results in a prototype vehicle, additionally comparing to existing implementations, simulation based as well as experimental. Finally we discuss the influence of start-stop and hybrid systems on the operation strategy of the adsorption air-conditioning system.

Keywords: adsorption air-conditioning, feasibility study, optimized control strategy, prototype vehicle

Procedia PDF Downloads 409
329 A Study on Changing of Energy-Saving Performance of GHP Air Conditioning System with Time-Series Variation

Authors: Ying Xin, Shigeki Kametani

Abstract:

This paper deals the energy saving performance of GHP (Gas engine heat pump) air conditioning system has improved with time-series variation. There are two types of air conditioning systems, VRF (Variable refrigerant flow) and central cooling and heating system. VRF is classified as EHP (Electric driven heat pump) and GHP. EHP drives the compressor with electric motor. GHP drives the compressor with the gas engine. The electric consumption of GHP is less than one tenth of EHP does. In this study, the energy consumption data of GHP installed the junior high schools was collected. An annual and monthly energy consumption per rated thermal output power of each apparatus was calculated, and then their energy efficiency was analyzed. From these data, we investigated improvement of the energy saving of the GHP air conditioning system by the change in the generation.

Keywords: energy-saving, variable refrigerant flow, gas engine heat pump, electric driven heat pump, air conditioning system

Procedia PDF Downloads 269
328 A Numerical and Experimental Analysis of the Performance of a Combined Solar Unit for Air Conditioning and Water Desalination

Authors: Zied Guidara, Alexander Morgenstern, Aref Younes Maalej

Abstract:

In this paper, a desiccant solar unit for air conditioning and desalination is presented first. Secondly, a dynamic modelling study of the desiccant wheel is developed. After that, a simulation study and an experimental investigation of the behaviour of desiccant wheel are developed. The experimental investigation is done in the chamber of commerce in Freiburg-Germany. Indeed, the variations of calculated and measured temperatures and specific humidity of dehumidified and rejected air are presented where a good agreement is found when comparing the model predictions with experimental data under the considered range of operating conditions. Finally, the study of the compartments of desalination and water condensation shows that the unit can produce an acceptable quantity of water at the same time of the air conditioning operation.

Keywords: air conditioning, desalination, condensation, design, desiccant wheel

Procedia PDF Downloads 466
327 Biochemical Evaluation of Air Conditioning West Water in Jeddah City: Concept of Sustainable Water Resources

Authors: D. Alromi, A. Alansari, S. Alghamdi, E. Jambi

Abstract:

As the need for water is increasing globally, and the available water resources are barely meeting the current quality of life and economy. Air conditioning (AC) condensate water could be explored as an alternative water source, which could be considered within the global calculations of the water supply. The objective of this study is to better understand the potential for recovery of condensate water from air conditioning systems. The results generated so far showed that the AC produces a high quantity of water, and data analysis revealed that the amount of water is positively and significantly correlated with the humidity (P <= 0.05). In the meantime, the amount of heavy metals has been measuring using ICP-OES. The results, in terms of quantity, clearly show that the AC can be used as an alternative source of water, especially in the regions characterized by high humidity. The results also showed that the amount of produced water depends on the type of AC.

Keywords: air conditioning systems, water quantity, water resources, wastewater

Procedia PDF Downloads 174
326 Effects of Synchronous Music in Gymnastics' Motor Skill Performance among Undergraduate Female Students in Physical Education College

Authors: Sanaa Ali Ahmed Alrashid

Abstract:

The present study aimed to investigate the effect of synchronous music in gymnastics' motor skill performance among undergraduate female students in physical education college at Basra University. The researcher used an experimental design. 20 female students of physical education divided equally into two groups, (10)experimental group with music, (10) control group without music. All participants complete 8 weeks in testing. Data analysis based on T-test shows a significant difference at (α = 0.05) in all skills level between experimental and control groups in favor of the experimental group. Results of this study contribute to developing the role of synchronous music in improving gymnastic skills performance.

Keywords: performance, motor skill, music, synchronous

Procedia PDF Downloads 461
325 Experts' Opinions of Considerations for Competition Landings in Gymnastics

Authors: Helmut Geiblinger

Abstract:

Dismounts performed by elite gymnasts during competition require great courage and virtuoso displays of precisely organized movements and skills. The dismount and landing leave the final impression in a routine and are often the key to a successful evaluation by the judges. Landings require precise body control and the skillful dissipation of substantial body momentum. The aim of this research study was to investigate landing techniques and strategies used by elite male gymnasts through the eyes of gymnastics experts. It drew from the accrued knowledge and experience of 21 male expert participants who were elite coaches, elite gymnasts, international judges or combinations of these. The experts made a number of subtle points, many of which are not in the extant literature. The experts highlighted concerns about safety and the study concluded that on-going monitoring of the rules on competition landings within the Code of Points would be beneficial to the sport.

Keywords: controlled competition landings, landing technique, landing strategies, optimal body segment coordination

Procedia PDF Downloads 187
324 New Desiccant Solar Unit for Air Conditioning and Desalination: Study of the Compartments of Desalination and Water Condensation

Authors: Zied Guidara, Alexander Morgenstern, Aref Maalej

Abstract:

In this paper, a new desiccant solar unit for air conditioning and desalination is presented first. Secondly, a dynamic modelling study of the desiccant wheel is developed. After that, a simulation study and an experimental investigation of the behaviour of the desiccant wheel are developed. The experimental investigation is done in the chamber of commerce in Freiburg-Germany. Indeed, the variations of calculated and measured temperatures and specific humidity of dehumidified and rejected air are presented where a good agreement is found when comparing the model predictions with experimental data under the considered range of operating conditions. Finally, the study of the compartments of desalination and water condensation shows that the unit can produce an acceptable quantity of water at the same time of the air conditioning operation.

Keywords: air conditioning, desalination, condensation, design, desiccant wheel, modelling, experimental investigation

Procedia PDF Downloads 361
323 Post Occupancy Evaluation of the Green Office Building with Different Air-Conditioning Systems

Authors: Ziwei Huang, Jian Ge, Jie Shen, Jiantao Weng

Abstract:

Retrofitting of existing buildings plays a critical role to achieve sustainable development. This is being considered as one of the approaches to achieving sustainability in the built environment. In order to evaluate the different air-conditioning systems effectiveness and user satisfaction of the existing building which had transformed into green building effectively and accurately. This article takes the green office building in Zhejiang province, China as an example, analyzing the energy consumption, occupant satisfaction and indoor environment quality (IEQ) from the perspective of the thermal environment. This building is special because it combines ground source heat pump system and Variable Refrigerant Flow (VRF) air-conditioning system. Results showed that the ground source heat pump system(EUIa≈25.6) consumes more energy than VRF(EUIb≈23.8). In terms of a satisfaction survey, the use of the VRF air-conditioning was more satisfactory in temperature. However, the ground source heat pump is more satisfied in air quality.

Keywords: post-occupancy evaluation, green office building, air-conditioning systems, ground source heat pump system

Procedia PDF Downloads 172
322 Impact of School-Based Gymnastic Program on Skill-Related Fitness in Early Adolescent Students

Authors: Dinko Vuleta, Dejan Madić, Goran Sporiš, Nebojša Trajković

Abstract:

The aim of this study was to determine the effects of gymnastics program in school on skill-related fitness in early adolescent students. The study involved 58 adolescent students (12.82±0.54 years; Height 156.81±8.16 cm; 53.46±12.31 kg) from primary school divided into two groups, following the randomization. The gymnastic group was involved in a 12 week of gymnastics classes, while the control group only participated in usual PE classes which consisted of multi-sport activities. The variables were selected within the several fitness batteries, measuring coordination (polygon backwards), upper and lower body strength standing long jump and medicine ball throw), speed (20 m sprint) and agility (4x10 test). Pre-test to post-test values showed significant improvements in all tested variables (p<0.05), except for the 4x10m test, where there were no significant improvements in neither of the groups (p>0.05). Significant interactions of time by group were observed for coordination, sprint speed, standing long jump and medicine ball throw (p<0.05). The results showed significant increase in skill-related fitness of the participants in the gymnastic group compared to the control group. Therefore, participation in gymnastics must be recommended as a positive foundational activity for school-aged children, from early childhood to adulthood. Additionally, the results can provide useful information in optimizing the training loads of pupils involved in gymnastic training throughout PE classes.

Keywords: effects, PE classes, physical fitness, training

Procedia PDF Downloads 238
321 Strategies for Tackling Climate Change: Review of Sustainability and Air-Conditioning

Authors: Tosin T. Oye, Keng Goh, Naren Gupta, Toyosi K. Oye

Abstract:

One of the most extreme difficulties confronting humankind in the twenty-first century is the consumption of energy. Non-renewable energy sources have been the fundamental energy assets for human culture. The consumption of energy sources emanating from the use of air-conditioning is still causing and has caused harm to the environment and human health. The request for energy could be double or perhaps triple in the future because of the utilization of air-conditioning systems as the worldwide population develops and emerging districts grow their economics. This has recently raised worries in sustainable development over climate change, global warming, ozone layer reduction, health issues, and possible supply problems. As a result of the improvement of way of life, air-conditioning has generally been applied. Nevertheless, environmental pollutions and health issues related with the use of air-conditioning unfolds more as often as possible. In order to diminish their level of undesirable impact on the environment, it is essential to establish suitable strategies for tackling climate change. Therefore, this paper aims to review and analyze studies in sustainability and air- conditioning and subsequently suggest strategies for combatting climate change. Future perspectives for tackling climate change are likewise suggested. The key findings revealed that it is required to establish sustainability measures to reduce the level of energy consumption and carbon emissions in a bid to effectively tackle climate change and its impact on the environment, and then raise public alertness towards the adverse impact of climate change arising from the use of air-conditioning systems. The research outcome offers valuable awareness to the general public, organizations, policymakers, and the government in making future municipal zones sustainable and more climate resilient.

Keywords: air-conditioning, climate change, environment, human health, sustainability

Procedia PDF Downloads 100
320 Performance Analysis of Air Conditioning System Working on the Vapour Compression Refrigeration Cycle under Magnetohydrodynamic Influence

Authors: Nikhil S. Mane, Mukund L. Harugade, Narayan V. Hargude, Vishal P. Patil

Abstract:

The fluids exposed to magnetic field can enhance the convective heat transfer by inducing secondary convection currents due to Lorentz force. The use of magnetohydrodynamic (MHD) forces in power generation and mass transfer is increasing steadily but its application to enhance the convective currents in fluids needed to be explored. The enhancement in convective heat transfer using MHD forces can be employed in heat exchangers, cooling of molten metal, vapour compression refrigeration (VCR) systems etc. The effective increase in the convective heat transfer without any additional energy consumption will lead to the energy efficient heat exchanging devices. In this work, the effect of MHD forces on the performance of air conditioning system working on the VCR system is studied. The refrigerant in VCR system is exposed to the magnetic field which influenced the flow of refrigerant. The different intensities of magnets are used on the different liquid refrigerants and investigation on performance of split air conditioning system is done under different loading conditions. The results of this research work show that the application of magnet on refrigerant flow has positive influence on the coefficient of performance (COP) of split air conditioning system. It is also observed that with increasing intensity of magnetic force the COP of split air conditioning system also increases.

Keywords: magnetohydrodynamics, heat transfer enhancement, VCRS, air conditioning, refrigeration

Procedia PDF Downloads 181
319 Performance Investigation of Silica Gel Fluidized Bed

Authors: Sih-Li Chen, Chih-Hao Chen, Chi-Tong Chan

Abstract:

Poor ventilation and high carbon dioxide (CO2) concentrations lead to the formation of sick buildings. This problem cannot simply be resolved by introducing fresh air from outdoor environments because this creates extra loads on indoor air-conditioning systems. Desiccants are widely used in air conditioning systems in tropical and subtropical regions with high humidity to reduce the latent heat load from fresh air. Desiccants are usually used as a packed-bed type, which is low cost, to combine with air-conditioning systems. Nevertheless, the pressure drop of a packed bed is too high, and the heat of adsorption caused by the adsorption process lets the temperature of the outlet air increase, bringing about an extra heat load, so the high pressure drop and the increased temperature of the outlet air are energy consumption sources needing to be resolved. For this reason, the gas-solid fluidised beds that have high heat and mass transfer rates, uniform properties and low pressure drops are very suitable for use in air-conditioning systems.This study experimentally investigates the performance of silica gel fluidized bed device which applying to an air conditioning system. In the experiments, commercial silica gel particles were filled in the two beds and to form a fixed packed bed and a fluidized bed. The results indicated that compared to the fixed packed bed device, the total adsorption and desorption by amounts of fluidized bed for 40 minutes increased 20.6% and 19.9% respectively when the bed height was 10 cm and superficial velocity was set to 2 m/s. In addition, under this condition, the pressure drop and outlet air temperature raise were reduced by 36.0% and 30.0%. Given the above results, application of the silica gel fluidized bed to air conditioning systems has great energy-saving potential.

Keywords: fluidized bed, packed bed, silica gel, adsorption, desorption, pressure drop

Procedia PDF Downloads 503
318 Assessment of the Effect of Building Materials on Energy Demand of Buildings in Jos: An Experimental and Numerical Approach

Authors: Zwalnan Selfa Johnson, Caleb Nanchen Nimyel, Gideon Duvuna Ayuba

Abstract:

Air conditioning accounts for a significant share of the overall energy consumed in residential buildings. Solar thermal gains in buildings account for a significant component of the air conditioning load in buildings. This study compares the solar thermal gain and air conditioning load of a proposed building design with a typical conventional building in the climatic conditions of Jos, Nigeria, using a combined experimental and computational method using TRNSYS software. According to the findings of this study, the proposed design building's annual average solar thermal gains are lower compared to the reference building's average solar heat gains. The study case building's decreased solar heat gain is mostly attributable to the lower temperature of the building zones because of the greater building volume and lower fenestration ratio (ratio external opening area to the area of the external walls). This result shows that the proposed building design adjusts to the local climate better than the standard conventional construction in Jos to maintain a suitable temperature within the building. This finding means that the air-conditioning electrical energy consumption per volume of the proposed building design will be lower than that of a conventional building design.

Keywords: solar heat gain, building zone, cooling energy, air conditioning, zone temperature

Procedia PDF Downloads 60
317 The Influence of Training on the Special Aerial Gymnastics Instruments on Selected C-Reactive Proteins in Cadets’ Serum

Authors: Z. Wochyński, K. A. Sobiech, Z. Kobos

Abstract:

To C-Reactive Proteins include ferritin, transferrin, and ceruloplasmin- metalloproteins. The study aimed at assessing an effect of training on the Special Aerial Gymnastics Instruments (SAGI) on changes of serum ferritin, transferrin, and ceruloplasmin and cadets’ physical fitness in comparison with a control group. Fifty-five cadets in the mean age 20 years were included into this study. They were divided into two groups: Group A (N=41) trained on SAGI and Group B (N=14) trained according the standard program of physical education (control group). In both groups, blood was a material for assays. Samples were collected twice before and after training at the start of the program (training I), during (training II), and after education program completion (training III). Commercially available kits were used to assay blood serum ferritin, transferrin, and ceruloplasmin. Cadets’ physical fitness was evaluated with exercise tests before and after education program completion. In Group A, serum post-exercise ferritin decreased statistically insignificantly in training I and II and increased in training III in comparison with pre-exercise values. In Group B, post-exercise serum ferritin decreased statistically insignificantly in training I and III and significantly increased in training II in comparison with the pre-exercise values. In Group A, serum transferrin decreased statistically insignificantly in training I, and significantly increased in training II, whereas in training III it increased insignificantly in comparison with pre-exercise values. In Group B, post-exercise serum transferrin increased statistically significantly in training I, II, and III in comparison with pre-exercise values. I n Group A, serum ceruloplasmin decreased in all three series in comparison with pre-exercise values. In Group B, serum ceruloplasmin increased significantly in training II. It was showed that the training on SAGI significantly decreased serum ceruloplasmin in Group A in all three series of assays and did not produce significant changes in serum ferritin also was showed significant increase in serum transferrin.

Keywords: special aerial gymnastics instruments, ferritin, ceruloplasmin, transferrin

Procedia PDF Downloads 440
316 Design Practices, Policies and Guidelines towards Implementing Architectural Passive Cooling Strategies in Public Library Buildings in Temperate Climates

Authors: Lesley Metibogun, Regan Potangaroa

Abstract:

Some existing sustainable public libraries in New Zealand now depend on air conditioning system for cooling. This seems completely contradictory to sustainable building initiatives. A sustainable building should be ‘self- sufficient’ and must aim at optimising the use of natural ventilation, wind and daylight and avoiding too much summer heat penetration into the building, to save energy consumption and enhance occupants’ comfort. This paper demonstrates that with appropriate architectural passive design input public libraries do not require air conditioning. Following a brief outline of how our dependence on air conditioning has spread over the full range of building types and climatic zones, this paper focuses on public libraries in temperate climates where passive cooling should be feasible for long periods of mild outside temperature. It was found that current design policies, regulations and guidelines and current building design practices militate passive cooling strategies. Perceived association with prestige, inflexibility of design process, rigid planning regulations and sustainability rating systems were identified as key factors forcing the need for air conditioning. Recommendations are made on how to further encourage development in this direction from the perspective of architectural design. This paper highlights how architectural passive cooling design strategies should be implemented in government initiated policies and regulations to develop a more sustainable public libraries.

Keywords: public library, sustainable design, temperate climate, passive cooling, air conditioning

Procedia PDF Downloads 222
315 Length Dimension Correlates of Longitudinal Physical Conditioning on Indian Male Youth

Authors: Seema Sharma Kaushik, Dhananjoy Shaw

Abstract:

Various length dimensions of the body have been a variable of interest in the research areas of kinanthropometry. However the inclusion of length measurements in various studies remains restricted to reflect characteristics of a particular game/sport at a particular time. Hence, the present investigation was conducted to study various length dimensions correlates of a longitudinal physical conditioning program on Indian male youth. The study was conducted on 90 Indian male youth. The sample was equally divided into three groups namely, progressive load training (PLT), constant load training (CLT) and no load training (NL). The variables included sitting height, leg length, arm length and foot length. The study was conducted by adopting the multi group repeated measure design. Three different groups were measured four times after completion of each of the three meso-cycles of six-weeks duration each. The measurements were taken using the standard landmarks and procedures. Mean, standard deviation and analysis of co-variance were computed to analyze the data statistically. The post-hoc analysis was conducted for the significant F-ratios at 0.05 level. The study concluded that the followed longitudinal physical conditioning program had significant effect on various length dimensions of Indian male youth.

Keywords: Indian male youth, longitudinal, length dimensions, physical conditioning

Procedia PDF Downloads 127
314 Disassociating Preferences from Evaluations Towards Pseudo Drink Brands

Authors: Micah Amd

Abstract:

Preferences towards unfamiliar drink brands can be predictably influenced following correlations of subliminally-presented brands (CS) with positively valenced attributes (US). Alternatively, evaluations towards subliminally-presented CS may be more variable, suggesting that CS-evoked evaluations may disassociate from CS-associated preferences following subliminal CS-US conditioning. We assessed this hypothesis over three experiments (Ex1, Ex2, Ex3). Across each experiment, participants first provided preferences and evaluations towards meaningless trigrams (CS) as a baseline, followed by conditioning and a final round of preference and evaluation measurements. During conditioning, four pairs of subliminal and supraliminal/visible CS were respectively correlated with four US categories varying along aggregate valence (e.g., 100% positive, 80% positive, 40% positive, 0% positive – for Ex1 and Ex2). Across Ex1 and Ex2, presentation durations for subliminal CS were 34 and 17 milliseconds, respectively. Across Ex3, aggregate valences of the four US categories were altered (75% positive, 55% positive, 45% positive, 25% positive). Valence across US categories was manipulated to address a supplemental query of whether US-to-CS valence transfer was summative or integrative. During analysis, we computed two sets of difference scores reflecting pre-post preference and evaluation performances, respectively. These were subjected to Bayes tests. Across all experiments, results illustrated US-to-CS valence transfer was most likely to shift evaluations for visible CS, but least likely to shift evaluations for subliminal CS. Alternatively, preferences were likely to shift following correlations with single-valence categories (e.g., 100% positive, 100% negative) across both visible and subliminal CS. Our results suggest that CS preferences can be influenced through subliminal conditioning even as CS evaluations remain unchanged, supporting our central hypothesis. As for whether transfer effects are summative/integrative, our results were more mixed; a comparison of relative likelihoods revealed that preferences are more likely to reflect summative effects whereas evaluations reflect integration, independent of visibility condition.

Keywords: subliminal conditioning, evaluations, preferences, valence transfer

Procedia PDF Downloads 131
313 The Fuzzy Logic Modeling of Performance Driver Seat’s Localised Cooling and Heating in Standard Car Air Conditioning System

Authors: Ali Ates, Sadık Ata, Kevser Dincer

Abstract:

In this study, performance of the driver seat‘s localized cooling and heating in a standard car air conditioning system was experimentally investigated and modeled with Rule-Based Mamdani-Type Fuzzy (RBMTF) modeling technique. Climate function at automobile is an important variable for thermal comfort. In the experimental study localized heating and cooling performances have been examined with the aid of a mechanism established to a vehicle. The equipment’s used in the experimental setup/mechanism have been provided and assembled. During the measurement, the status of the performance level has been determined. Input parameters revolutions per minute and time; output parameters car seat cooling temperature, car back cooling temperature, car seat heating temperature, car back heating temperature were described by RBMTF if-the rules. Numerical parameters of input and output variables were fuzzificated as linguistic variables: Very Very Low (L1), Very Low (L2), Low (L3), Negative Medium (L4), Medium (L5), High (L7), Very High (L8) and Very Very High (L9) linguistic classes. The comparison between experimental data and RBMTF is done by using statistical methods like absolute fraction of variance (R2). The actual values and RBMTF results indicated that RBMTF could be successfully used in standard car air conditioning system.

Keywords: air conditioning system, cooling-heating, RMBTF modelling, car seat

Procedia PDF Downloads 329
312 Ionic Liquid Desiccant for the Dehumidification System

Authors: Chih-Hao Chen, Yu-Heng Fang, Jyi-Ching Perng, Wei-Chih Lee, Yi-Hsiang Chen, Jiun-Jen Chen

Abstract:

Emerging markets are almost in the high temperature and high humidity area. Regardless of industry or domestic fields, the energy consumption of air conditioning systems in buildings is always significant. Moreover, the proportion of latent heat load is high. A liquid desiccant dehumidification system is one kind of energy-saving air conditioning system. However, traditional absorbents such as lithium chloride are hindered in market promotion because they will crystallized and cause metal corrosion. This study used the commercial ionic liquid to build a liquid desiccant dehumidification system with an air volume of 300 CMH. When the absolute humidity of the inlet air was 15g/kg, the absolute humidity of the outlet air was 10g/kg. The operating condition of a hot water temperature is 45 °C, and the cooling water temperature is 15 °C. The test result proves that the ionic liquid desiccant can completely replace the traditional liquid desiccant.

Keywords: ionic liquid desiccant, dehumidification, heat pump, air conditioning systems

Procedia PDF Downloads 129
311 A Theoretical and Experimental Evaluation of a Solar-Powered Off-Grid Air Conditioning System for Residential Buildings

Authors: Adam Y. Sulaiman, Gerard I.Obasi, Roma Chang, Hussein Sayed Moghaieb, Ming J. Huang, Neil J. Hewitt

Abstract:

Residential air-conditioning units are essential for quality indoor comfort in hot climate countries. Nevertheless, because of their non-renewable energy sources and the contribution of ecologically unfriendly working fluids, these units are a major source of CO2 emissions in these countries. The utilisation of sustainable technologies nowadays is essential to reduce the adverse effects of CO2 emissions by replacing conventional technologies. This paper investigates the feasibility of running an off-grid solar-powered air-conditioning bed unit using three low GWP refrigerants (R32, R290, and R600a) to supersede conventional refrigerants.A prototype air conditioning unit was built to supply cold air to a canopy that was connected to it. The assembled unit was designed to distribute cold air to a canopy connected to it. This system is powered by two 400 W photovoltaic panels, with battery storage supplying power to the unit at night-time. Engineering Equation Solver (EES) software is used to mathematically model the vapor compression cycle (VCC) and predict the unit's energetic and exergetic performance. The TRNSYS software was used to simulate the electricity storage performance of the batteries, whereas the IES-VE was used to determine the amount of solar energy required to power the unit. The article provides an analytical design guideline, as well as a comprehensible process system. Combining a renewable energy source to power an AC based-VCC provides an excellent solution to the real problems of high-energy consumption in warm-climate countries.

Keywords: air-conditioning, refrigerants, PV panel, energy storages, VCC, exergy

Procedia PDF Downloads 150