Search results for: automatic incident detection
1756 Thickness Measurement and Void Detection in Concrete Elements through Ultrasonic Pulse
Authors: Leonel Lipa Cusi, Enrique Nestor Pasquel Carbajal, Laura Marina Navarro Alvarado, José Del Álamo Carazas
Abstract:
This research analyses the accuracy of the ultrasound and the pulse echo ultrasound technic to find voids and to measure thickness of concrete elements. These mentioned air voids are simulated by polystyrene expanded and hollow containers of thin thickness made of plastic or cardboard of different sizes and shapes. These targets are distributed strategically inside concrete at different depths. For this research, a shear wave pulse echo ultrasonic device of 50 KHz is used to scan the concrete elements. Despite the small measurements of the concrete elements and because of voids’ size are near the half of the wavelength, pre and post processing steps like voltage, gain, SAFT, envelope and time compensation were made in order to improve imaging results.Keywords: ultrasonic, concrete, thickness, pulse echo, void
Procedia PDF Downloads 3311755 Heavy Vehicle Traffic Estimation Using Automatic Traffic Recorders/Weigh-In-Motion Data: Current Practice and Proposed Methods
Authors: Muhammad Faizan Rehman Qureshi, Ahmed Al-Kaisy
Abstract:
Accurate estimation of traffic loads is critical for pavement and bridge design, among other transportation applications. Given the disproportional impact of heavier axle loads on pavement and bridge structures, truck and heavy vehicle traffic is expected to be a major determinant of traffic load estimation. Further, heavy vehicle traffic is also a major input in transportation planning and economic studies. The traditional method for estimating heavy vehicle traffic primarily relies on AADT estimation using Monthly Day of the Week (MDOW) adjustment factors as well as the percent heavy vehicles observed using statewide data collection programs. The MDOW factors are developed using daily and seasonal (or monthly) variation patterns for total traffic, consisting predominantly of passenger cars and other smaller vehicles. Therefore, while using these factors may yield reasonable estimates for total traffic (AADT), such estimates may involve a great deal of approximation when applied to heavy vehicle traffic. This research aims at assessing the approximation involved in estimating heavy vehicle traffic using MDOW adjustment factors for total traffic (conventional approach) along with three other methods of using MDOW adjustment factors for total trucks (class 5-13), combination-unit trucks (class 8-13), as well as adjustment factors for each vehicle class separately. Results clearly indicate that the conventional method was outperformed by the other three methods by a large margin. Further, using the most detailed and data intensive method (class-specific adjustment factors) does not necessarily yield a more accurate estimation of heavy vehicle traffic.Keywords: traffic loads, heavy vehicles, truck traffic, adjustment factors, traffic data collection
Procedia PDF Downloads 231754 Parameters Identification and Sensitivity Study for Abrasive WaterJet Milling Model
Authors: Didier Auroux, Vladimir Groza
Abstract:
This work is part of STEEP Marie-Curie ITN project, and it focuses on the identification of unknown parameters of the proposed generic Abrasive WaterJet Milling (AWJM) PDE model, that appears as an ill-posed inverse problem. The necessity of studying this problem comes from the industrial milling applications where the possibility to predict and model the final surface with high accuracy is one of the primary tasks in the absence of any knowledge of the model parameters that should be used. In this framework, we propose the identification of model parameters by minimizing a cost function, measuring the difference between experimental and numerical solutions. The adjoint approach based on corresponding Lagrangian gives the opportunity to find out the unknowns of the AWJM model and their optimal values that could be used to reproduce the required trench profile. Due to the complexity of the nonlinear problem and a large number of model parameters, we use an automatic differentiation software tool (TAPENADE) for the adjoint computations. By adding noise to the artificial data, we show that in fact the parameter identification problem is highly unstable and strictly depends on input measurements. Regularization terms could be effectively used to deal with the presence of data noise and to improve the identification correctness. Based on this approach we present results in 2D and 3D of the identification of the model parameters and of the surface prediction both with self-generated data and measurements obtained from the real production. Considering different types of model and measurement errors allows us to obtain acceptable results for manufacturing and to expect the proper identification of unknowns. This approach also gives us the ability to distribute the research on more complex cases and consider different types of model and measurement errors as well as 3D time-dependent model with variations of the jet feed speed.Keywords: Abrasive Waterjet Milling, inverse problem, model parameters identification, regularization
Procedia PDF Downloads 3161753 Ultrasonography of Low Extremities Veins Before and After Replacement of Knee Joint by Endoprosthesis
Authors: A. V. Alabut, V. D. Sikilinda, N. J. Nelasov, O. L. Eroshenko, M. N. Morgunov, I. V. Koroleva
Abstract:
We have analyzed the results of treatment of 204 patients with knee prosthetic arthroplasty. For the purpose of active delineation of vascular pathology triplex sonography of arterial and venous vessels of low extremities was performed in all cases in the preoperative period. When it was necessary, reconstructive vascular surgery was implemented to improve peripheral circulation and reduce the hazard of thrombosis after knee replacement. The combination of specific and nonspecific methods of thromboprophylaxis was used in perioperative period. On 7-10 day and 2.5-3 month after prosthetic arthroplasty, all patients iteratively underwent triple sonography. In case of detection of floating thrombus, urgent venous ligation was performed. Active diagnostics of venous thrombosis gave the opportunity to avoid fatal pulmonary embolism.Keywords: knee replacement, venous thrombosis, pulmonary embolism, vascular surgery
Procedia PDF Downloads 3691752 Full Characterization of Heterogeneous Antibody Samples under Denaturing and Native Conditions on a Hybrid Quadrupole-Orbitrap Mass Spectrometer
Authors: Rowan Moore, Kai Scheffler, Eugen Damoc, Jennifer Sutton, Aaron Bailey, Stephane Houel, Simon Cubbon, Jonathan Josephs
Abstract:
Purpose: MS analysis of monoclonal antibodies (mAbs) at the protein and peptide levels is critical during development and production of biopharmaceuticals. The compositions of current generation therapeutic proteins are often complex due to various modifications which may affect efficacy. Intact proteins analyzed by MS are detected in higher charge states that also provide more complexity in mass spectra. Protein analysis in native or native-like conditions with zero or minimal organic solvent and neutral or weakly acidic pH decreases charge state value resulting in mAb detection at higher m/z ranges with more spatial resolution. Methods: Three commercially available mAbs were used for all experiments. Intact proteins were desalted online using size exclusion chromatography (SEC) or reversed phase chromatography coupled on-line with a mass spectrometer. For streamlined use of the LC- MS platform we used a single SEC column and alternately selected specific mobile phases to perform separations in either denaturing or native-like conditions: buffer A (20 % ACN, 0.1 % FA) with Buffer B (100 mM ammonium acetate). For peptide analysis mAbs were proteolytically digested with and without prior reduction and alkylation. The mass spectrometer used for all experiments was a commercially available Thermo Scientific™ hybrid Quadrupole-Orbitrap™ mass spectrometer, equipped with the new BioPharma option which includes a new High Mass Range (HMR) mode that allows for improved high mass transmission and mass detection up to 8000 m/z. Results: We have analyzed the profiles of three mAbs under reducing and native conditions by direct infusion with offline desalting and with on-line desalting via size exclusion and reversed phase type columns. The presence of high salt under denaturing conditions was found to influence the observed charge state envelope and impact mass accuracy after spectral deconvolution. The significantly lower charge states observed under native conditions improves the spatial resolution of protein signals and has significant benefits for the analysis of antibody mixtures, e.g. lysine variants, degradants or sequence variants. This type of analysis requires the detection of masses beyond the standard mass range ranging up to 6000 m/z requiring the extended capabilities available in the new HMR mode. We have compared each antibody sample that was analyzed individually with mixtures in various relative concentrations. For this type of analysis, we observed that apparent native structures persist and ESI is benefited by the addition of low amounts of acetonitrile and formic acid in combination with the ammonium acetate-buffered mobile phase. For analyses on the peptide level we analyzed reduced/alkylated, and non-reduced proteolytic digests of the individual antibodies separated via reversed phase chromatography aiming to retrieve as much information as possible regarding sequence coverage, disulfide bridges, post-translational modifications such as various glycans, sequence variants, and their relative quantification. All data acquired were submitted to a single software package for analysis aiming to obtain a complete picture of the molecules analyzed. Here we demonstrate the capabilities of the mass spectrometer to fully characterize homogeneous and heterogeneous therapeutic proteins on one single platform. Conclusion: Full characterization of heterogeneous intact protein mixtures by improved mass separation on a quadrupole-Orbitrap™ mass spectrometer with extended capabilities has been demonstrated.Keywords: disulfide bond analysis, intact analysis, native analysis, mass spectrometry, monoclonal antibodies, peptide mapping, post-translational modifications, sequence variants, size exclusion chromatography, therapeutic protein analysis, UHPLC
Procedia PDF Downloads 3611751 An Optimal Steganalysis Based Approach for Embedding Information in Image Cover Media with Security
Authors: Ahlem Fatnassi, Hamza Gharsellaoui, Sadok Bouamama
Abstract:
This paper deals with the study of interest in the fields of Steganography and Steganalysis. Steganography involves hiding information in a cover media to obtain the stego media in such a way that the cover media is perceived not to have any embedded message for its unintended recipients. Steganalysis is the mechanism of detecting the presence of hidden information in the stego media and it can lead to the prevention of disastrous security incidents. In this paper, we provide a critical review of the steganalysis algorithms available to analyze the characteristics of an image stego media against the corresponding cover media and understand the process of embedding the information and its detection. We anticipate that this paper can also give a clear picture of the current trends in steganography so that we can develop and improvise appropriate steganalysis algorithms.Keywords: optimization, heuristics and metaheuristics algorithms, embedded systems, low-power consumption, steganalysis heuristic approach
Procedia PDF Downloads 2921750 A Green Method for Selective Spectrophotometric Determination of Hafnium(IV) with Aqueous Extract of Ficus carica Tree Leaves
Authors: A. Boveiri Monji, H. Yousefnia, M. Haji Hosseini, S. Zolghadri
Abstract:
A clean spectrophotometric method for the determination of hafnium by using a green reagent, acidic extract of Ficus carica tree leaves is developed. In 6-M hydrochloric acid, hafnium reacts with this reagent to form a yellow product. The formed product shows maximum absorbance at 421 nm with a molar absorptivity value of 0.28 × 104 l mol⁻¹ cm⁻¹, and the method was linear in the 2-11 µg ml⁻¹ concentration range. The detection limit value was found to be 0.312 µg ml⁻¹. Except zirconium and iron, the selectivity was good, and most of the ions did not show any significant spectral interference at concentrations up to several hundred times. The proposed method was green, simple, low cost, and selective.Keywords: spectrophotometric determination, Ficus caricatree leaves, synthetic reagents, hafnium
Procedia PDF Downloads 2091749 Development of a New Polymeric Material with Controlled Surface Micro-Morphology Aimed for Biosensors Applications
Authors: Elham Farahmand, Fatimah Ibrahim, Samira Hosseini, Ivan Djordjevic, Leo. H. Koole
Abstract:
Compositions of different molar ratios of polymethylmethacrylate-co-methacrylic acid (PMMA-co-MAA) were synthesized via free- radical polymerization. Polymer coated surfaces have been produced on silicon wafers. Coated samples were analyzed by atomic force microscopy (AFM). The results have shown that the roughness of the surfaces have increased by increasing the molar ratio of monomer methacrylic acid (MAA). This study reveals that the gradual increase in surface roughness is due to the fact that carboxylic functional groups have been generated by MAA segments. Such surfaces can be desirable platforms for fabrication of the biosensors for detection of the viruses and diseases.Keywords: polymethylmethacrylate-co-methacrylic acid (PMMA-co-MAA), polymeric material, atomic force microscopy, roughness, carboxylic functional groups
Procedia PDF Downloads 5951748 Robust Diagnosability of PEMFC Based on Bond Graph LFT
Authors: Ould Bouamama, M. Bressel, D. Hissel, M. Hilairet
Abstract:
Fuel cell (FC) is one of the best alternatives of fossil energy. Recently, the research community of fuel cell has shown a considerable interest for diagnosis in view to ensure safety, security, and availability when faults occur in the process. The problematic for model based FC diagnosis consists in that the model is complex because of coupling of several kind of energies and the numerical values of parameters are not always known or are uncertain. The present paper deals with use of one tool: the Linear Fractional Transformation bond graph tool not only for uncertain modelling but also for monitorability (ability to detect and isolate faults) analysis and formal generation of robust fault indicators with respect to parameter uncertainties.The developed theory applied to a nonlinear FC system has proved its efficiency.Keywords: bond graph, fuel cell, fault detection and isolation (FDI), robust diagnosis, structural analysis
Procedia PDF Downloads 3661747 Impact of pH Control on Peptide Profile and Antigenicity of Whey Hydrolysates
Authors: Natalia Caldeira De Carvalho, Tassia Batista Pessato, Luis Gustavo R. Fernandes, Ricardo L. Zollner, Flavia Maria Netto
Abstract:
Protein hydrolysates are ingredients of enteral diets and hypoallergenic formulas. Enzymatic hydrolysis is the most commonly used method for reducing the antigenicity of milk protein. The antigenicity and physicochemical characteristics of the protein hydrolysates depend on the reaction parameters. Among them, pH has been pointed out as of the major importance. Hydrolysis reaction in laboratory scale is commonly carried out under controlled pH (pH-stat). However, from the industrial point of view, controlling pH during hydrolysis reaction may be infeasible. This study evaluated the impact of pH control on the physicochemical properties and antigenicity of the hydrolysates of whey proteins with Alcalase. Whey protein isolate (WPI) solutions containing 3 and 7 % protein (w/v) were hydrolyzed with Alcalase 50 and 100 U g-1 protein at 60°C for 180 min. The reactions were carried out under controlled and uncontrolled pH conditions. Hydrolyses performed under controlled pH (pH-stat) were initially adjusted and maintained at pH 8.5. Hydrolyses carried out without pH control were initially adjusted to pH 8.5. Degree of hydrolysis (DH) was determined by OPA method, peptides profile was evaluated by HPLC-RP, and molecular mass distribution by SDS-PAGE/Tricine. The residual α-lactalbumin (α-La) and β-lactoglobulin (β-Lg) concentrations were determined using commercial ELISA kits. The specific IgE and IgG binding capacity of hydrolysates was evaluated by ELISA technique, using polyclonal antibodies obtained by immunization of female BALB/c mice with α-La, β-Lg and BSA. In hydrolysis under uncontrolled pH, the pH dropped from 8.5 to 7.0 during the first 15 min, remaining constant throughout the process. No significant difference was observed between the DH of the hydrolysates obtained under controlled and uncontrolled pH conditions. Although all hydrolysates showed hydrophilic character and low molecular mass peptides, hydrolysates obtained with and without pH control exhibited different chromatographic profiles. Hydrolysis under uncontrolled pH released, predominantly, peptides between 3.5 and 6.5 kDa, while hydrolysis under controlled pH released peptides smaller than 3.5 kDa. Hydrolysis with Alcalase under all conditions studied decreased by 99.9% the α-La and β-Lg concentrations in the hydrolysates detected by commercial kits. In general, β-Lg concentrations detected in the hydrolysates obtained under uncontrolled pH were significantly higher (p<0.05) than those detected in hydrolysates produced with pH control. The anti-α-La and anti-β-Lg IgE and IgG responses to all hydrolysates decreased significantly compared to WPI. Levels of specific IgE and IgG to the hydrolysates were below 25 and 12 ng ml-1, respectively. Despite the differences in peptide composition and α-La and β-Lg concentrations, no significant difference was found between IgE and IgG binding capacity of hydrolysates obtained with or without pH control. These results highlight the impact of pH on the hydrolysates characteristics and their concentrations of antigenic protein. Divergence between the antigen detection by commercial ELISA kits and specific IgE and IgG binding response was found in this study. This result shows that lower protein detection does not imply in lower protein antigenicity. Thus, the use of commercial kits for allergen contamination analysis should be cautious.Keywords: allergy, enzymatic hydrolysis, milk protein, pH conditions, physicochemical characteristics
Procedia PDF Downloads 3031746 An Approach Based on Statistics and Multi-Resolution Representation to Classify Mammograms
Authors: Nebi Gedik
Abstract:
One of the significant and continual public health problems in the world is breast cancer. Early detection is very important to fight the disease, and mammography has been one of the most common and reliable methods to detect the disease in the early stages. However, it is a difficult task, and computer-aided diagnosis (CAD) systems are needed to assist radiologists in providing both accurate and uniform evaluation for mass in mammograms. In this study, a multiresolution statistical method to classify mammograms as normal and abnormal in digitized mammograms is used to construct a CAD system. The mammogram images are represented by wave atom transform, and this representation is made by certain groups of coefficients, independently. The CAD system is designed by calculating some statistical features using each group of coefficients. The classification is performed by using support vector machine (SVM).Keywords: wave atom transform, statistical features, multi-resolution representation, mammogram
Procedia PDF Downloads 2221745 Facilitating Written Biology Assessment in Large-Enrollment Courses Using Machine Learning
Authors: Luanna B. Prevost, Kelli Carter, Margaurete Romero, Kirsti Martinez
Abstract:
Writing is an essential scientific practice, yet, in several countries, the increasing university science class-size limits the use of written assessments. Written assessments allow students to demonstrate their learning in their own words and permit the faculty to evaluate students’ understanding. However, the time and resources required to grade written assessments prohibit their use in large-enrollment science courses. This study examined the use of machine learning algorithms to automatically analyze student writing and provide timely feedback to the faculty about students' writing in biology. Written responses to questions about matter and energy transformation were collected from large-enrollment undergraduate introductory biology classrooms. Responses were analyzed using the LightSide text mining and classification software. Cohen’s Kappa was used to measure agreement between the LightSide models and human raters. Predictive models achieved agreement with human coding of 0.7 Cohen’s Kappa or greater. Models captured that when writing about matter-energy transformation at the ecosystem level, students focused on primarily on the concepts of heat loss, recycling of matter, and conservation of matter and energy. Models were also produced to capture writing about processes such as decomposition and biochemical cycling. The models created in this study can be used to provide automatic feedback about students understanding of these concepts to biology faculty who desire to use formative written assessments in larger enrollment biology classes, but do not have the time or personnel for manual grading.Keywords: machine learning, written assessment, biology education, text mining
Procedia PDF Downloads 2811744 Hand Gestures Based Emotion Identification Using Flex Sensors
Authors: S. Ali, R. Yunus, A. Arif, Y. Ayaz, M. Baber Sial, R. Asif, N. Naseer, M. Jawad Khan
Abstract:
In this study, we have proposed a gesture to emotion recognition method using flex sensors mounted on metacarpophalangeal joints. The flex sensors are fixed in a wearable glove. The data from the glove are sent to PC using Wi-Fi. Four gestures: finger pointing, thumbs up, fist open and fist close are performed by five subjects. Each gesture is categorized into sad, happy, and excited class based on the velocity and acceleration of the hand gesture. Seventeen inspectors observed the emotions and hand gestures of the five subjects. The emotional state based on the investigators assessment and acquired movement speed data is compared. Overall, we achieved 77% accurate results. Therefore, the proposed design can be used for emotional state detection applications.Keywords: emotion identification, emotion models, gesture recognition, user perception
Procedia PDF Downloads 2851743 Artificial Neural Networks with Decision Trees for Diagnosis Issues
Authors: Y. Kourd, D. Lefebvre, N. Guersi
Abstract:
This paper presents a new idea for fault detection and isolation (FDI) technique which is applied to industrial system. This technique is based on Neural Networks fault-free and Faulty behaviors Models (NNFM's). NNFM's are used for residual generation, while decision tree architecture is used for residual evaluation. The decision tree is realized with data collected from the NNFM’s outputs and is used to isolate detectable faults depending on computed threshold. Each part of the tree corresponds to specific residual. With the decision tree, it becomes possible to take the appropriate decision regarding the actual process behavior by evaluating few numbers of residuals. In comparison to usual systematic evaluation of all residuals, the proposed technique requires less computational effort and can be used for on line diagnosis. An application example is presented to illustrate and confirm the effectiveness and the accuracy of the proposed approach.Keywords: neural networks, decision trees, diagnosis, behaviors
Procedia PDF Downloads 5051742 Close-Range Remote Sensing Techniques for Analyzing Rock Discontinuity Properties
Authors: Sina Fatolahzadeh, Sergio A. Sepúlveda
Abstract:
This paper presents advanced developments in close-range, terrestrial remote sensing techniques to enhance the characterization of rock masses. The study integrates two state-of-the-art laser-scanning technologies, the HandySCAN and GeoSLAM laser scanners, to extract high-resolution geospatial data for rock mass analysis. These instruments offer high accuracy, precision, low acquisition time, and high efficiency in capturing intricate geological features in small to medium size outcrops and slope cuts. Using the HandySCAN and GeoSLAM laser scanners facilitates real-time, three-dimensional mapping of rock surfaces, enabling comprehensive assessments of rock mass characteristics. The collected data provide valuable insights into structural complexities, surface roughness, and discontinuity patterns, which are essential for geological and geotechnical analyses. The synergy of these advanced remote sensing technologies contributes to a more precise and straightforward understanding of rock mass behavior. In this case, the main parameters of RQD, joint spacing, persistence, aperture, roughness, infill, weathering, water condition, and joint orientation in a slope cut along the Sea-to-Sky Highway, BC, were remotely analyzed to calculate and evaluate the Rock Mass Rating (RMR) and Geological Strength Index (GSI) classification systems. Automatic and manual analyses of the acquired data are then compared with field measurements. The results show the usefulness of the proposed remote sensing methods and their appropriate conformity with the actual field data.Keywords: remote sensing, rock mechanics, rock engineering, slope stability, discontinuity properties
Procedia PDF Downloads 661741 Development of an Autonomous Automated Guided Vehicle with Robot Manipulator under Robot Operation System Architecture
Authors: Jinsiang Shaw, Sheng-Xiang Xu
Abstract:
This paper presents the development of an autonomous automated guided vehicle (AGV) with a robot arm attached on top of it within the framework of robot operation system (ROS). ROS can provide libraries and tools, including hardware abstraction, device drivers, libraries, visualizers, message-passing, package management, etc. For this reason, this AGV can provide automatic navigation and parts transportation and pick-and-place task using robot arm for typical industrial production line use. More specifically, this AGV will be controlled by an on-board host computer running ROS software. Command signals for vehicle and robot arm control and measurement signals from various sensors are transferred to respective microcontrollers. Users can operate the AGV remotely through the TCP / IP protocol and perform SLAM (Simultaneous Localization and Mapping). An RGBD camera and LIDAR sensors are installed on the AGV, using these data to perceive the environment. For SLAM, Gmapping is used to construct the environment map by Rao-Blackwellized particle filter; and AMCL method (Adaptive Monte Carlo localization) is employed for mobile robot localization. In addition, current AGV position and orientation can be visualized by ROS toolkit. As for robot navigation and obstacle avoidance, A* for global path planning and dynamic window approach for local planning are implemented. The developed ROS AGV with a robot arm on it has been experimented in the university factory. A 2-D and 3-D map of the factory were successfully constructed by the SLAM method. Base on this map, robot navigation through the factory with and without dynamic obstacles are shown to perform well. Finally, pick-and-place of parts using robot arm and ensuing delivery in the factory by the mobile robot are also accomplished.Keywords: automated guided vehicle, navigation, robot operation system, Simultaneous Localization and Mapping
Procedia PDF Downloads 1501740 Auto Calibration and Optimization of Large-Scale Water Resources Systems
Authors: Arash Parehkar, S. Jamshid Mousavi, Shoubo Bayazidi, Vahid Karami, Laleh Shahidi, Arash Azaranfar, Ali Moridi, M. Shabakhti, Tayebeh Ariyan, Mitra Tofigh, Kaveh Masoumi, Alireza Motahari
Abstract:
Water resource systems modelling have constantly been a challenge through history for human being. As the innovative methodological development is evolving alongside computer sciences on one hand, researches are likely to confront more complex and larger water resources systems due to new challenges regarding increased water demands, climate change and human interventions, socio-economic concerns, and environment protection and sustainability. In this research, an automatic calibration scheme has been applied on the Gilan’s large-scale water resource model using mathematical programming. The water resource model’s calibration is developed in order to attune unknown water return flows from demand sites in the complex Sefidroud irrigation network and other related areas. The calibration procedure is validated by comparing several gauged river outflows from the system in the past with model results. The calibration results are pleasantly reasonable presenting a rational insight of the system. Subsequently, the unknown optimized parameters were used in a basin-scale linear optimization model with the ability to evaluate the system’s performance against a reduced inflow scenario in future. Results showed an acceptable match between predicted and observed outflows from the system at selected hydrometric stations. Moreover, an efficient operating policy was determined for Sefidroud dam leading to a minimum water shortage in the reduced inflow scenario.Keywords: auto-calibration, Gilan, large-scale water resources, simulation
Procedia PDF Downloads 3351739 Analyzing the Evolution and Maturation of Bitcoin Improvement Proposals
Authors: Rodrigo Costa, Thomas Mazzuchi, Shahram Sarkani
Abstract:
This study analyzes the evolution of Bitcoin Improvement Proposals (BIPs), the self-governing mechanism that enables updates to the Bitcoin protocol. By modeling BIP submission frequencies with a Negative Binomial distribution and detecting change points with the Pelt Rupture model, we identify three distinct intervals of proposal activity, suggesting shifts in development priorities over time. Long-term growth patterns, captured by Gompertz and Weibull models, indicate an S-shaped trend in cumulative BIP counts, pointing toward a maturation phase in Bitcoin’s protocol. Our findings suggest that Bitcoin may be entering a stable stage, with fewer fundamental changes and more incremental enhancements. This trend highlights the need for further research into BIP content and more studies into its dynamics to better understand decentralized protocol governance and maturation.Keywords: bitcoin improvement proposals, innovation management, change point detection, systems modeling, simulation
Procedia PDF Downloads 91738 Ibrutinib and the Potential Risk of Cardiac Failure: A Review of Pharmacovigilance Data
Authors: Abdulaziz Alakeel, Roaa Alamri, Abdulrahman Alomair, Mohammed Fouda
Abstract:
Introduction: Ibrutinib is a selective, potent, and irreversible small-molecule inhibitor of Bruton's tyrosine kinase (BTK). It forms a covalent bond with a cysteine residue (CYS-481) at the active site of Btk, leading to inhibition of Btk enzymatic activity. The drug is indicated to treat certain type of cancers such as mantle cell lymphoma (MCL), chronic lymphocytic leukaemia and Waldenström's macroglobulinaemia (WM). Cardiac failure is a condition referred to inability of heart muscle to pump adequate blood to human body organs. There are multiple types of cardiac failure including left and right-sided heart failure, systolic and diastolic heart failures. The aim of this review is to evaluate the risk of cardiac failure associated with the use of ibrutinib and to suggest regulatory recommendations if required. Methodology: Signal Detection team at the National Pharmacovigilance Center (NPC) of Saudi Food and Drug Authority (SFDA) performed a comprehensive signal review using its national database as well as the World Health Organization (WHO) database (VigiBase), to retrieve related information for assessing the causality between cardiac failure and ibrutinib. We used the WHO- Uppsala Monitoring Centre (UMC) criteria as standard for assessing the causality of the reported cases. Results: Case Review: The number of resulted cases for the combined drug/adverse drug reaction are 212 global ICSRs as of July 2020. The reviewers have selected and assessed the causality for the well-documented ICSRs with completeness scores of 0.9 and above (35 ICSRs); the value 1.0 presents the highest score for best-written ICSRs. Among the reviewed cases, more than half of them provides supportive association (four probable and 15 possible cases). Data Mining: The disproportionality of the observed and the expected reporting rate for drug/adverse drug reaction pair is estimated using information component (IC), a tool developed by WHO-UMC to measure the reporting ratio. Positive IC reflects higher statistical association while negative values indicates less statistical association, considering the null value equal to zero. The results of (IC=1.5) revealed a positive statistical association for the drug/ADR combination, which means “Ibrutinib” with “Cardiac Failure” have been observed more than expected when compared to other medications available in WHO database. Conclusion: Health regulators and health care professionals must be aware for the potential risk of cardiac failure associated with ibrutinib and the monitoring of any signs or symptoms in treated patients is essential. The weighted cumulative evidences identified from causality assessment of the reported cases and data mining are sufficient to support a causal association between ibrutinib and cardiac failure.Keywords: cardiac failure, drug safety, ibrutinib, pharmacovigilance, signal detection
Procedia PDF Downloads 1291737 Presenting a Knowledge Mapping Model According to a Comparative Study on Applied Models and Approaches to Map Organizational Knowledge
Authors: Ahmad Aslizadeh, Farid Ghaderi
Abstract:
Mapping organizational knowledge is an innovative concept and useful instrument of representation, capturing and visualization of implicit and explicit knowledge. There are a diversity of methods, instruments and techniques presented by different researchers following mapping organizational knowledge to reach determined goals. Implicating of these methods, it is necessary to know their exigencies and conditions in which those can be used. Integrating identified methods of knowledge mapping and comparing them would help knowledge managers to select the appropriate methods. This research conducted to presenting a model and framework to map organizational knowledge. At first, knowledge maps, their applications and necessity are introduced because of extracting comparative framework and detection of their structure. At the next step techniques of researchers such as Eppler, Kim, Egbu, Tandukar and Ebner as knowledge mapping models are presented and surveyed. Finally, they compare and a superior model would be introduced.Keywords: knowledge mapping, knowledge management, comparative study, business and management
Procedia PDF Downloads 4031736 Integration of a Protective Film to Enhance the Longevity and Performance of Miniaturized Ion Sensors
Authors: Antonio Ruiz Gonzalez, Kwang-Leong Choy
Abstract:
The measurement of electrolytes has a high value in the clinical routine. Ions are present in all body fluids with variable concentrations and are involved in multiple pathologies such as heart failures and chronic kidney disease. In the case of dissolved potassium, although a high concentration in the blood (hyperkalemia) is relatively uncommon in the general population, it is one of the most frequent acute electrolyte abnormalities. In recent years, the integration of thin films technologies in this field has allowed the development of highly sensitive biosensors with ultra-low limits of detection for the assessment of metals in liquid samples. However, despite the current efforts in the miniaturization of sensitive devices and their integration into portable systems, only a limited number of successful examples used commercially can be found. This fact can be attributed to a high cost involved in their production and the sustained degradation of the electrodes over time, which causes a signal drift in the measurements. Thus, there is an unmet necessity for the development of low-cost and robust sensors for the real-time monitoring of analyte concentrations in patients to allow the early detection and diagnosis of diseases. This paper reports a thin film ion-selective sensor for the evaluation of potassium ions in aqueous samples. As an alternative for this fabrication method, aerosol assisted chemical vapor deposition (AACVD), was applied due to cost-effectivity and fine control over the film deposition. Such a technique does not require vacuum and is suitable for the coating of large surface areas and structures with complex geometries. This approach allowed the fabrication of highly homogeneous surfaces with well-defined microstructures onto 50 nm thin gold layers. The degradative processes of the ubiquitously employed poly (vinyl chloride) membranes in contact with an electrolyte solution were studied, including the polymer leaching process, mechanical desorption of nanoparticles and chemical degradation over time. Rational design of a protective coating based on an organosilicon material in combination with cellulose to improve the long-term stability of the sensors was then carried out, showing an improvement in the performance after 5 weeks. The antifouling properties of such coating were assessed using a cutting-edge quartz microbalance sensor, allowing the quantification of the adsorbed proteins in the nanogram range. A correlation between the microstructural properties of the films with the surface energy and biomolecules adhesion was then found and used to optimize the protective film.Keywords: hyperkalemia, drift, AACVD, organosilicon
Procedia PDF Downloads 1231735 The Comparison between Modelled and Measured Nitrogen Dioxide Concentrations in Cold and Warm Seasons in Kaunas
Authors: A. Miškinytė, A. Dėdelė
Abstract:
Road traffic is one of the main sources of air pollution in urban areas associated with adverse effects on human health and environment. Nitrogen dioxide (NO2) is considered as traffic-related air pollutant, which concentrations tend to be higher near highways, along busy roads and in city centres and exceedances are mainly observed in air quality monitoring stations located close to traffic. Atmospheric dispersion models can be used to examine emissions from many various sources and to predict the concentration of pollutants emitted from these sources into the atmosphere. The study aim was to compare modelled concentrations of nitrogen dioxide using ADMS-Urban dispersion model with air quality monitoring network in cold and warm seasons in Kaunas city. Modelled average seasonal concentrations of nitrogen dioxide for 2011 year have been verified with automatic air quality monitoring data from two stations in the city. Traffic station is located near high traffic street in industrial district and background station far away from the main sources of nitrogen dioxide pollution. The modelling results showed that the highest nitrogen dioxide concentration was modelled and measured in station located near intensive traffic street, both in cold and warm seasons. Modelled and measured nitrogen dioxide concentration was respectively 25.7 and 25.2 µg/m3 in cold season and 15.5 and 17.7 µg/m3 in warm season. While the lowest modelled and measured NO2 concentration was determined in background monitoring station, respectively 12.2 and 13.3 µg/m3 in cold season and 6.1 and 7.6 µg/m3 in warm season. The difference between monitoring station located near high traffic street and background monitoring station showed that better agreement between modelled and measured NO2 concentration was observed at traffic monitoring station.Keywords: air pollution, nitrogen dioxide, modelling, ADMS-Urban model
Procedia PDF Downloads 4081734 Numerical Study of Fiber Bragg Grating Sensor: Longitudinal and Transverse Detection of Temperature and Strain
Authors: K. Khelil, H. Ammar, K. Saouchi
Abstract:
Fiber Bragg Grating (FBG) structure is an periodically modulated optical fiber. It acts as a selective filter of wavelength whose reflected peak is called Bragg wavelength and it depends on the period of the fiber and the refractive index. The simulation of FBG is based on solving the Coupled Mode Theory equation by using the Transfer Matrix Method which is carried out using MATLAB. It is found that spectral reflectivity is shifted when the change of temperature and strain is uniform. Under non-uniform temperature or strain perturbation, the spectrum is both shifted and destroyed. In case of transverse loading, reflectivity spectrum is split into two peaks, the first is specific to X axis, and the second belongs to Y axis. FBGs are used in civil engineering to detect perturbations applied to buildings.Keywords: Bragg wavelength, coupled mode theory, optical fiber, temperature measurement
Procedia PDF Downloads 4941733 Analysis of Underground Logistics Transportation Technology and Planning Research: Based on Xiong'an New Area, China
Authors: Xia Luo, Cheng Zeng
Abstract:
Under the promotion of the Central Committee of the Communist Party of China and the State Council in 2017, Xiong'an New Area is the third crucial new area in China established after Shenzhen and Shanghai. Its constructions' significance lies in mitigating Beijing's non-capital functions and exploring a new mode of optimizing development in densely populated and economically intensive areas. For this purpose, developing underground logistics can assume the role of goods distribution in the capital, relieve the road transport pressure in Beijing-Tianjin-Hebei Urban Agglomeration, adjust and optimize the urban layout and spatial structure of it. Firstly, the construction planning of Xiong'an New Area and underground logistics development are summarized, especially the development status abroad, the development trend, and bottlenecks of underground logistics in China. This paper explores the technicality, feasibility, and necessity of four modes of transportation. There are pneumatic capsule pipeline (PCP) technology, the CargoCap technology, cable hauled mule, and automatic guided vehicle (AGV). The above technical parameters and characteristics are introduced to relevant experts or scholars. Through establishing an indicator system, carrying out a questionnaire survey with the Delphi method, the final suggestion is obtained: China should develop logistics vehicles similar to CargoCap, adopting rail mode and driverless mode. Based on China's temporal and spatial logistics demand and the geographical pattern of Xiong'an New Area, the construction scale, technical parameters, node location, and other vital parameters of underground logistics are planned. In this way, we hope to speed up the new area's construction and the logistics industry's innovation.Keywords: the Xiong'an new area, underground logistics, contrastive analysis, CargoCap, logistics planning
Procedia PDF Downloads 1291732 The Effects of “Never Pressure Injury” on the Incidence of Pressure Injuries in Critically Ill Patients
Authors: Nuchjaree Kidjawan, Orapan Thosingha, Pawinee Vaipatama, Prakrankiat Youngkong, Sirinapha Malangputhong, Kitti Thamrongaphichartkul, Phatcharaporn Phetcharat
Abstract:
NPI uses technology sensorization of things and processed by AI system. The main features are an individual interface pressure sensor system in contact with the mattress and a position management system where the sensor detects the determined pressure with automatic pressure reduction and distribution. The role of NPI is to monitor, identify the risk and manage the interface pressure automatically when the determined pressure is detected. This study aims to evaluate the effects of “Never Pressure Injury (NPI),” an innovative mattress, on the incidence of pressure injuries in critically ill patients. An observational case-control study was employed to compare the incidence of pressure injury between the case and the control group. The control group comprised 80 critically ill patients admitted to a critical care unit of Phyathai3 Hospital, receiving standard care with the use of memory foam according to intensive care unit guidelines. The case group comprised 80 critically ill patients receiving standard care and with the use of the Never Pressure Injury (NPI) innovation mattress. The patients who were over 20 years old and showed scores of less than 18 on the Risk Assessment Pressure Ulcer Scale – ICU and stayed in ICU for more than 24 hours were selected for the study. The patients’ skin was assessed for the occurrence of pressure injury once a day for five consecutive days or until the patients were discharged from ICU. The sample comprised 160 patients with ages ranging from 30-102 (mean = 70.1 years), and the Body Mass Index ranged from 13.69- 49.01 (mean = 24.63). The case and the control group were not different in their sex, age, Body Mass Index, Pressure Ulcer Risk Scores, and length of ICU stay. Twenty-two patients (27.5%) in the control group had pressure injuries, while no pressure injury was found in the case group.Keywords: pressure injury, never pressure injury, innovation mattress, critically ill patients, prevent pressure injury
Procedia PDF Downloads 1241731 Study of Silent Myocardial Ischemia in Type 2 Diabeic Males: Egyptian Experience
Authors: Ali Kassem, Yhea Kishik, Ali Hassan, Mohamed Abdelwahab
Abstract:
Introduction: Accelerated coronary and peripheral vascular atherosclerosis is one of the most common and chronic complications of diabetes mellitus. A recent aspect of coronary artery disease in this condition is its silent nature. The aim of the work: Detection of the prevalence of silent myocardial ischemia (SMI) in Upper Egypt type 2 diabetic males and to select male diabetic population who should be screened for SMI. Patients and methods: 100 type 2 diabetic male patients with a negative history of angina or anginal equivalent symptoms and 30 healthy control were included. Full medical history and thorough clinical examination were done for all participants. Fasting and post prandial blood glucose level, lipid profile, (HbA1c), microalbuminuria, and C-reactive protein were done for all participants Resting ECG, trans-thoracic echocardiography, treadmill exercise ECG, myocardial perfusion imaging were done for all participants and patients positive for one or more NITs were subjected for coronary angiography. Results Twenty nine patients (29%) were positive for one or more NITs in the patients group compared to only one case (3.3%) in the controls. After coronary angiography, 20 patients were positive for significant coronary artery stenosis in the patients group, while it was refused to be done by the patient in the controls. There were statistical significant difference between the two groups regarding, hypertension, dyslipidemia and obesity, family history of DM and IHD with higher levels of microalbuminuria, C-reactive protein, total lipids in patient group versus controls According to coronary angiography, patients were subdivided into two subgroups, 20 positive for SMI (positive for coronary angiography) and 80 negative for SMI (negative for coronary angiography). No statistical difference regarding family history of DM and type of diabetic therapy was found between the two subgroups. Yet, smoking, hypertension, obesity, dyslipidemia and family history of IHD were significantly higher in diabetics positive versus those negative for SMI. 90% of patients in subgroup positive for SMI had two or more cardiac risk factors while only two patients had one cardiac risk factor (10%). Uncontrolled DM was detected more in patients positive for SMI. Diabetic complications were more prevalent in patients positive for SMI versus those negative for SMI. Most of the patients positive for SMI have DM more than 5 years duration. Resting ECG and resting Echo detected only 6 and 11 cases, respectively, of the 20 positive cases in group positive for SMI compared to treadmill exercise ECG and myocardial perfusion imaging that detected 16 and 18 cases respectively, Conclusion: Type 2 diabetic male patients should be screened for detection of SMI when aged above 50 years old, diabetes duration is more than 5 years, presence of two or more cardiac risk factors and/or patients suffering from one or more of the chronic diabetic complications. CRP, is an important parameter for selection of type 2 diabetic male patients who should be screened for SMI. Non invasive cardiac tests are reliable for screening of SMI in these patients in our locality.Keywords: C-reactive protein, Silent myocardial ischemia, Stress tests, type 2 DM
Procedia PDF Downloads 3851730 TutorBot+: Automatic Programming Assistant with Positive Feedback based on LLMs
Authors: Claudia Martínez-Araneda, Mariella Gutiérrez, Pedro Gómez, Diego Maldonado, Alejandra Segura, Christian Vidal-Castro
Abstract:
The purpose of this document is to showcase the preliminary work in developing an EduChatbot-type tool and measuring the effects of its use aimed at providing effective feedback to students in programming courses. This bot, hereinafter referred to as tutorBot+, was constructed based on chatGPT and is tasked with assisting and delivering timely positive feedback to students in the field of computer science at the Universidad Católica de Concepción. The proposed working method consists of four stages: (1) Immersion in the domain of Large Language Models (LLMs), (2) Development of the tutorBot+ prototype and integration, (3) Experiment design, and (4) Intervention. The first stage involves a literature review on the use of artificial intelligence in education and the evaluation of intelligent tutors, as well as research on types of feedback for learning and the domain of chatGPT. The second stage encompasses the development of tutorBot+, and the final stage involves a quasi-experimental study with students from the Programming and Database labs, where the learning outcome involves the development of computational thinking skills, enabling the use and measurement of the tool's effects. The preliminary results of this work are promising, as a functional chatBot prototype has been developed in both conversational and non-conversational versions integrated into an open-source online judge and programming contest platform system. There is also an exploration of the possibility of generating a custom model based on a pre-trained one tailored to the domain of programming. This includes the integration of the created tool and the design of the experiment to measure its utility.Keywords: assessment, chatGPT, learning strategies, LLMs, timely feedback
Procedia PDF Downloads 681729 A Radiomics Approach to Predict the Evolution of Prostate Imaging Reporting and Data System Score 3/5 Prostate Areas in Multiparametric Magnetic Resonance
Authors: Natascha C. D'Amico, Enzo Grossi, Giovanni Valbusa, Ala Malasevschi, Gianpiero Cardone, Sergio Papa
Abstract:
Purpose: To characterize, through a radiomic approach, the nature of areas classified PI-RADS (Prostate Imaging Reporting and Data System) 3/5, recognized in multiparametric prostate magnetic resonance with T2-weighted (T2w), diffusion and perfusion sequences with paramagnetic contrast. Methods and Materials: 24 cases undergoing multiparametric prostate MR and biopsy were admitted to this pilot study. Clinical outcome of the PI-RADS 3/5 was found through biopsy, finding 8 malignant tumours. The analysed images were acquired with a Philips achieva 1.5T machine with a CE- T2-weighted sequence in the axial plane. Semi-automatic tumour segmentation was carried out on MR images using 3DSlicer image analysis software. 45 shape-based, intensity-based and texture-based features were extracted and represented the input for preprocessing. An evolutionary algorithm (a TWIST system based on KNN algorithm) was used to subdivide the dataset into training and testing set and select features yielding the maximal amount of information. After this pre-processing 20 input variables were selected and different machine learning systems were used to develop a predictive model based on a training testing crossover procedure. Results: The best machine learning system (three-layers feed-forward neural network) obtained a global accuracy of 90% ( 80 % sensitivity and 100% specificity ) with a ROC of 0.82. Conclusion: Machine learning systems coupled with radiomics show a promising potential in distinguishing benign from malign tumours in PI-RADS 3/5 areas.Keywords: machine learning, MR prostate, PI-Rads 3, radiomics
Procedia PDF Downloads 1881728 Adaptive Online Object Tracking via Positive and Negative Models Matching
Authors: Shaomei Li, Yawen Wang, Chao Gao
Abstract:
To improve tracking drift which often occurs in adaptive tracking, an algorithm based on the fusion of tracking and detection is proposed in this paper. Firstly, object tracking is posed as a binary classification problem and is modeled by partial least squares (PLS) analysis. Secondly, tracking object frame by frame via particle filtering. Thirdly, validating the tracking reliability based on both positive and negative models matching. Finally, relocating the object based on SIFT features matching and voting when drift occurs. Object appearance model is updated at the same time. The algorithm cannot only sense tracking drift but also relocate the object whenever needed. Experimental results demonstrate that this algorithm outperforms state-of-the-art algorithms on many challenging sequences.Keywords: object tracking, tracking drift, partial least squares analysis, positive and negative models matching
Procedia PDF Downloads 5301727 In Vivo Evaluation of Exposure to Electromagnetic Fields at 27 GHz (5G) of Danio Rerio: A Preliminary Study
Authors: Elena Maria Scalisi, Roberta Pecoraro, Martina Contino, Sara Ignoto, Carmelo Iaria, Santi Concetto Pavone, Gino Sorbello, Loreto Di Donato, Maria Violetta Brundo
Abstract:
5G Technology is evolving to satisfy a variety of service requirements that may allow high data-rate connections (1Gbps) and lower latency times than current (<1ms). In order to support a high data transmission speed and a high traffic service for eMBB (enhanced mobile broadband) use cases, 5G systems have the characteristic of using different frequency bands of the radio wave spectrum (700 MHz, 3.6-3.8 GHz and 26.5-27.5 GHz), thus taking advantage of higher frequencies than previous mobile radio generations (1G-4G). However, waves at higher frequencies have a lower capacity to propagate in free space and therefore, in order to guarantee the capillary coverage of the territory for high reliability applications, it will be necessary to install a large number of repeaters. Following the introduction of this new technology, there has been growing concern over the past few months about possible harmful effects on human health. The aim of this preliminary study is to evaluate possible short term effects induced by 5G-millimeter waves on embryonic development and early life stages of Danio rerio by Z-FET. We exposed developing zebrafish at frequency of 27 GHz, with a standard pyramidal horn antenna placed at 15 cm far from the samples holder ensuring an incident power density of 10 mW/cm2. During the exposure cycle, from 6 h post fertilization (hpf) to 96 hpf, we measured a different morphological endpoints every 24 hours. Zebrafish embryo toxicity test (Z-FET) is a short term test, carried out on fertilized eggs of zebrafish and it represents an effective alternative to acute test with adult fish (OECD, 2013). We have observed that 5G did not reveal significant impacts on mortality nor on morphology because exposed larvae showed a normal detachment of the tail, presence of heartbeat, well-organized somites, therefore hatching rate was lower than untreated larvae even at 48 h of exposure. Moreover, the immunohistochemical analysis performed on larvae showed a negativity to the HSP-70 expression used as a biomarkers. This is a preliminary study on evaluation of potential toxicity induced by 5G and it seems appropriate to underline the importance that further studies would take, aimed at clarifying the probable real risk of exposure to electromagnetic fields.Keywords: Biomarker of exposure, embryonic development, 5G waves, zebrafish embryo toxicity test
Procedia PDF Downloads 129