Search results for: direct current control
21012 Trichoderma spp Consortium and Its Efficacy as Biological Control Agent of Ganoderma Disease of Oil Palm (Elaies guineensis Jacquin)
Authors: Habu Musa, Nusaibah Binti Syd Ali
Abstract:
Oil palm industries particularly in Malaysia and Indonesia are being devastated by Ganoderma disease caused by Ganoderma spp. To date, this disease has been causing serious oil palm yield losses and collapse of oil palm trees, thus affecting its contribution to the producer’s economy. Research on sustainable and eco-friendly remedy to counter Ganoderma disease is on the upsurge to avoid the current control measures via synthetic fungicides. Trichoderma species have been the most studied and valued microbes as biological control agents in an effort to combat a wide range of plant diseases sustainably. Therefore, in this current study, the potential of Trichoderma spp. (Trichoderma asperellum, Trichoderma harzianum, and Trichoderma virens) as a consortium approach was evaluated as biological control agents against Ganoderma disease on oil palm. The consortium of Trichoderma spp. applied found to be the most effective treatment in suppressing Ganoderma disease with 83.03% and 89.16% from the foliar and bole symptoms respectively. Besides, it exhibited tremendous enhancement in the oil palm seedling vegetative growth parameters. Also, it had highly induced significant activity of peroxidase, polyphenol oxidase and total phenolic content was recorded in the consortium treatment compared to the control treatment. Disease development was slower in the seedlings treated with consortium of Trichoderma spp. compared to the positive control, which exhibited with the highest percentage of disease severity.Keywords: biological control, ganoderma disease, trichoderma, disease severity
Procedia PDF Downloads 27721011 Optimization of Doubly Fed Induction Generator Equivalent Circuit Parameters by Direct Search Method
Authors: Mamidi Ramakrishna Rao
Abstract:
Doubly-fed induction generator (DFIG) is currently the choice for many wind turbines. These generators, when connected to the grid through a converter, is subjected to varied power system conditions like voltage variation, frequency variation, short circuit fault conditions, etc. Further, many countries like Canada, Germany, UK, Scotland, etc. have distinct grid codes relating to wind turbines. Accordingly, following the network faults, wind turbines have to supply a definite reactive current. To satisfy the requirements including reactive current capability, an optimum electrical design becomes a mandate for DFIG to function. This paper intends to optimize the equivalent circuit parameters of an electrical design for satisfactory DFIG performance. Direct search method has been used for optimization of the parameters. The variables selected include electromagnetic core dimensions (diameters and stack length), slot dimensions, radial air gap between stator and rotor and winding copper cross section area. Optimization for 2 MW DFIG has been executed separately for three objective functions - maximum reactive power capability (Case I), maximum efficiency (Case II) and minimum weight (Case III). In the optimization analysis program, voltage variations (10%), power factor- leading and lagging (0.95), speeds for corresponding to slips (-0.3 to +0.3) have been considered. The optimum designs obtained for objective functions were compared. It can be concluded that direct search method of optimization helps in determining an optimum electrical design for each objective function like efficiency or reactive power capability or weight minimization.Keywords: direct search, DFIG, equivalent circuit parameters, optimization
Procedia PDF Downloads 25721010 An Observer-Based Direct Adaptive Fuzzy Sliding Control with Adjustable Membership Functions
Authors: Alireza Gholami, Amir H. D. Markazi
Abstract:
In this paper, an observer-based direct adaptive fuzzy sliding mode (OAFSM) algorithm is proposed. In the proposed algorithm, the zero-input dynamics of the plant could be unknown. The input connection matrix is used to combine the sliding surfaces of individual subsystems, and an adaptive fuzzy algorithm is used to estimate an equivalent sliding mode control input directly. The fuzzy membership functions, which were determined by time consuming try and error processes in previous works, are adjusted by adaptive algorithms. The other advantage of the proposed controller is that the input gain matrix is not limited to be diagonal, i.e. the plant could be over/under actuated provided that controllability and observability are preserved. An observer is constructed to directly estimate the state tracking error, and the nonlinear part of the observer is constructed by an adaptive fuzzy algorithm. The main advantage of the proposed observer is that, the measured outputs is not limited to the first entry of a canonical-form state vector. The closed-loop stability of the proposed method is proved using a Lyapunov-based approach. The proposed method is applied numerically on a multi-link robot manipulator, which verifies the performance of the closed-loop control. Moreover, the performance of the proposed algorithm is compared with some conventional control algorithms.Keywords: adaptive algorithm, fuzzy systems, membership functions, observer
Procedia PDF Downloads 20721009 Determining Efficiency of Frequency Control System of Karkheh Power Plant in Main Network
Authors: Ferydon Salehifar, Hassan Safarikia, Hossein Boromandfar
Abstract:
Karkheh plant in Iran's Khuzestan province and is located in the city Andimeshk. The plant has a production capacity of 400 MW units with water and three hours. One of the important parameters of each country's power grid stability is the stability of the power grid is affected by the voltage and frequency In plants, the amount of active power frequency control is done so that when the unit is placed in the frequency control their productivity is a function of frequency and output power varies with frequency. Produced by hydroelectric power plants with the water level behind the dam has a direct relationship And to decrease and increase the water level behind the dam in order to reduce the power output increases But these changes have a different interval is due to some mechanical problems such as turbine cavitation and vibration are limited. In this study, the range of the frequency control can be Karkheh manufacturing plants have been identified and their effectiveness has been determined.Keywords: Karkheh power, frequency control system, active power, efficiency
Procedia PDF Downloads 62221008 Design and Analysis of a Piezoelectric-Based AC Current Measuring Sensor
Authors: Easa Ali Abbasi, Akbar Allahverdizadeh, Reza Jahangiri, Behnam Dadashzadeh
Abstract:
Electrical current measurement is a suitable method for the performance determination of electrical devices. There are two contact and noncontact methods in this measuring process. Contact method has some disadvantages like having direct connection with wire which may endamage the system. Thus, in this paper, a bimorph piezoelectric cantilever beam which has a permanent magnet on its free end is used to measure electrical current in a noncontact way. In mathematical modeling, based on Galerkin method, the governing equation of the cantilever beam is solved, and the equation presenting the relation between applied force and beam’s output voltage is presented. Magnetic force resulting from current carrying wire is considered as the external excitation force of the system. The results are compared with other references in order to demonstrate the accuracy of the mathematical model. Finally, the effects of geometric parameters on the output voltage and natural frequency are presented.Keywords: cantilever beam, electrical current measurement, forced excitation, piezoelectric
Procedia PDF Downloads 23421007 The Antecedents of Green Purchase Intention in Nigeria: Mediating Effect of Perceived Behavioral Control
Authors: Victoria Masi Haruna Karatu, Nik Kamariah Nikmat
Abstract:
In recent times awareness about the environment and green purchase has been on the increase across nations due to global warming. Previous researchers have attempted to determine what actually influences the purchase intention of consumers in this environmentally conscious epoch. The consumers too have become conscious of what to buy and who to buy from in their purchasing decisions as this action will reflect their concern about the environment and their personal well-being. This trend is a widespread phenomenon in most developed countries of the world. On the contrary evidence revealed that only 5% of the populations of Nigeria involve in green purchase activities thus making the country lag behind its counterparts in green practices. This is not a surprise as Nigeria is facing problems of inadequate green knowledge, non-enforcement of environmental regulations, sensitivity to the price of green products when compared with the conventional ones and distrust towards green products which has been deduced from prior studies of other regions. The main objectives of this study is to examine the direct antecedents of green purchase intention (green availability, government regulations, perceived green knowledge, perceived value and green price sensitivity) in Nigeria and secondly to establish the mediating role of perceived behavioral control on the relationship between these antecedents and green purchase intention. The study adopts quantitative method whereby 700 questionnaires were administered to lecturers in three Nigerian universities. 502 datasets were collected which represents 72 percent response rate. After screening the data only 440 were usable and analyzed using structural equation modeling (SEM) and bootstrapping. From the findings, three antecedents have significant direct relationships with green purchase intention (perceived green knowledge, perceived behavioral control, and green availability) while two antecedents have positive and significant direct relationship with perceived behavioral control (perceived value and green price sensitivity). On the other hand, PBC does not mediate any of the paths from the predictors to criterion variable. This result is discussed in the Nigerian context.Keywords: Green Availability, Green Price Sensitivity, Green Purchase Intention, Perceived Green Knowledge, Perceived Value
Procedia PDF Downloads 42721006 Detergent Removal from Rinsing Water by Peroxi Electrocoagulation Process
Authors: A. Benhadji, M. Taleb Ahmed
Abstract:
Among the various methods of treatment, advanced oxidation processes (AOP) are the most promising ones. In this study, Peroxi Electrocoagulation Process (PEP) was investigated for the treatment of detergent wastewater. The process was compared with electrooxidation treatment. The results showed that chemical oxygen demand (COD) was high 7584 mgO2.L-1, while the biochemical oxygen demand was low (250 mgO2.L-1). This wastewater was hardly biodegradable. Electrochemical process was carried out for the removal of detergent using a glass reactor with a volume of 1 L and fitted with three electrodes. A direct current (DC) supply was used. Samples were taken at various current density (0.0227 A/cm2 to 0.0378 A/cm2) and reaction time (1-2-3-4 and 5 hour). Finally, the COD was determined. The results indicated that COD removal efficiency of PEP was observed to increase with current intensity and reached to 77% after 5 h. The highest removal efficiency was observed after 5 h of treatment.Keywords: AOP, COD, detergent, PEP, wastewater
Procedia PDF Downloads 11921005 Biofouling Control during the Wastewater Treatment in Self-Support Carbon Nanotubes Membrane: Role of Low Voltage Electric Potential
Authors: Chidambaram Thamaraiselvan, Carlos Dosoretz
Abstract:
This work will explore the influence of low voltage electric field, both alternating (AC) and direct (DC) currents, on biofouling control to highly electrically conductive self-supporting carbon nanotubes (CNT) membranes at conditions which encourage bacterial growth. A mutant strain of Pseudomonas putida S12 was used a model bacterium. The antibiofouling studies were performed with flow-through mode connecting an electric circuit in resistive mode. Major emphasis was placed on AC due to its ability of repulsing and inactivating bacteria. The observations indicate that an AC potential >1500 mV, 1 kHz frequency, 100 Ω external resistance on ground side and pulse wave above the offset (+0.45) almost completely prevented attachment of bacteria (>98.5%) and bacterial inactivation (95.3±2.5%). Findings suggest that at the conditions applied, direct electron transfer might be dominant in a decrease of cell viability. AC resulted more effective than DC, both in terms of biofouling reduction compared to cathodic DC and in terms of cell inactivation compared to anodic DC. This electrically polarized CNT membranes offer a viable antibiofouling strategy to hinder biofouling and simplify membrane care during filtration.Keywords: bacterial attachment, biofouling control, low electric potential, water treatment
Procedia PDF Downloads 27021004 Review of Factors Which Affect Throttling by Oxidiser Flow Control in Hybrid Rocket Engine
Authors: Natcha Laethongkham, Gayan Ramanayake, Philip Charlesworth, Leshan Uggalla
Abstract:
The throttling process in hybrid rocket engines (HREs) poses challenges due to inherent instability, impacting the engine’s reliability and robustness. Identifying and advancing existing technology is crucial to meet the demands of complex mission profiles required for next-generation launch vehicles. This paper reviews the current literature, focusing on oxidiser flow control for throttling purposes in HREs. Covered areas include oxidiser choices, commonly used throttle valves, and literature trends. Common oxidisers for throttling are hydrogen peroxide, nitrous oxide, and liquid oxygen. Two frequently chosen valves for throttling are the ball and variation pintle valves. The review identifies two primary research focuses: flow control valve studies and control system design. The current research stage is highlighted, and suggestions for future directions are proposed to advance thrust control systems in HREs. This includes further studies in existing research focuses and exploring new approaches such as system scheme design, numerical modelling, and applications.Keywords: hybrid rocket engines, oxidiser flow control, thrust control, throttle valve, review
Procedia PDF Downloads 2721003 Sliding Mode Control of a Photovoltaic Grid-Connected System with Active and Reactive Power Control
Authors: M. Doumi, K. Tahir, A. Miloudi, A. G. Aissaoui, C. Belfedal, S. Tahir
Abstract:
This paper presents a three-phase grid-connected photovoltaic generation system with unity power factor for any situation of solar radiation based on voltage-oriented control (VOC). An input voltage clamping technique is proposed to control the power between the grid and photovoltaic system, where it is intended to achieve the maximum power point operation. This method uses a Perturb and Observe (P&O) controller. The main objective of this work is to compare the energy production unit performances by the use of two types of controllers (namely, classical PI and Sliding Mode (SM) Controllers) for the grid inverter control. The proposed control has a hierarchical structure with a grid side control level to regulate the power (PQ) and the current injected to the grid and to obtain a common DC voltage constant. To show the effectiveness of both control methods performances analysis of the system are analyzed and compared by simulation and results included in this paper.Keywords: grid connected photovoltaic, MPPT, inverter control, classical PI, sliding mode, DC voltage constant, voltage-oriented control, VOC
Procedia PDF Downloads 61121002 Rotor Side Speed Control Methods Using MATLAB/Simulink for Wound Induction Motor
Authors: Rajesh Kumar, Roopali Dogra, Puneet Aggarwal
Abstract:
In recent advancements in electric machine and drives, wound rotor motor is extensively used. The merit of using wound rotor induction motor is to control speed/torque characteristics by inserting external resistance. Wound rotor induction motor can be used in the cases such as (a) low inrush current, (b) load requiring high starting torque, (c) lower starting current is required, (d) loads having high inertia, and (e) gradual built up of torque. Examples include conveyers, cranes, pumps, elevators, and compressors. This paper includes speed control of wound induction motor using MATLAB/Simulink for rotor resistance and slip power recovery method. The characteristics of these speed control methods are hence analyzed.Keywords: MATLAB/Simulink, rotor resistance method, slip power recovery method, wound rotor induction motor
Procedia PDF Downloads 37221001 AC Electro-Kinetics, Bipolar Current and Concentration-Polarization in a Microchannel-Nafion Membrane System
Authors: Sinwook Park, Gilad Yossifon
Abstract:
The presence of a floating electrode array located within the depletion layer formed due to concentration-polarization (CP) across a microchannel-membrane device, produces not only induced-charge electro-osmosis (ICEO) vortex and but also a bipolar current resulting from faradaic reactions. It has been shown that there exists an optimal SiO2 layer thickness of ~50nm which is sufficient to suppress bipolar currents (at least up to 5V applied voltage) but still enables ICEO vortices that stir the depletion layer, thereby affecting its I-V response. This effect is pronounced beyond the limiting current where the existence of the depletion layer results in increased local electric field due to decreased solution conductivity. This comprehensive study of the interaction of embedded electrodes with the induced CP in microchannel-perm selective medium systems, allows one to choose the thickness of the thin dielectric coating to either enhance the mixing as a means to control the diffuse layer, or suppress it, for example, in the case where electrodes are intended for local measurements of the solution conductivity with minimal invasion. In addition, the use of alternating-current electro-osmosis by activating electrodes results in further enhancement of the fluid stirring and opens new routes for on-demand spatiotemporal control of the CP length. In addition, the use of embedded heaters within the depletion layer generates electro-thermal vortices that in turn also control the CP length.Keywords: AC electrokinetics, microchannel, concentration-polarization, bipolar current
Procedia PDF Downloads 49721000 Performance Comparison of Droop Control Methods for Parallel Inverters in Microgrid
Authors: Ahmed Ismail, Mustafa Baysal
Abstract:
Although the energy source in the world is mainly based on fossil fuels today, there is a need for alternative energy generation systems, which are more economic and environmentally friendly, due to continuously increasing demand of electric energy and lacking power resources and networks. Distributed Energy Resources (DERs) such as fuel cells, wind and solar power have recently become widespread as alternative generation. In order to solve several problems that might be encountered when integrating DERs to power system, the microgrid concept has been proposed. A microgrid can operate both grid connected and island mode to benefit both utility and customers. For most distributed energy resources (DER) which are connected in parallel in LV-grid like micro-turbines, wind plants, fuel cells and PV cells electrical power is generated as a direct current (DC) and converted to an alternative currents (AC) by inverters. So the inverters are assumed to be primary components in a microgrid. There are many control techniques of parallel inverters to manage active and reactive sharing of the loads. Some of them are based on droop method. In literature, the studies are usually focused on improving the transient performance of inverters. In this study, the performance of two different controllers based on droop control method is compared for the inverters operated in parallel without any communication feedback. For this aim, a microgrid in which inverters are controlled by conventional droop controller and modified droop controller is designed. Modified controller is obtained by adding PID into conventional droop control. Active and reactive power sharing performance, voltage and frequency responses of those control methods are measured in several operational cases. Study cases have been simulated by MATLAB-SIMULINK.Keywords: active and reactive power sharing, distributed generation, droop control, microgrid
Procedia PDF Downloads 59320999 Comparison of Proportional-Integral (P-I) and Integral-Propotional (I-P) Controllers for Speed Control in Vector Controlled Permanent Magnet Synchronous Motor Drive
Authors: V. Srikanth, K. Balasubramanian, Rajath R. Bhat, A. S. Arjun, Nandhu Venugopal, Ananthu Unnikrishnan
Abstract:
Indirect vector control is known to produce high performance in Permanent Magnet Synchronous Motor (PMSM) drives by decoupling flux and torque producing current components of stator current. The most commonly used controller or the vector control of AC motor is Proportional-Integral (P-I) controller. However, the P-I controller has some disadvantages such as high starting overshoot, sensitivity to controller gains and slower response to sudden disturbance. Therefore, the Integral-Proportional controller for PMSM drives to overcome the disadvantages of the P-I controller. Simulations results are presented and analyzed for both controllers and it is observed that Integral-Proportional (I-P) controllers give better responses than the traditional P-I controllers.Keywords: PMSM, FOC, PI controller, IP controller
Procedia PDF Downloads 36120998 Changes in Foreign Direct Investment Policy of India and Its Impact on Economic Development
Authors: Kishor P. Kadam
Abstract:
Foreign direct investment policy (FDI) is defined as an investment involving a long term relationship and reflecting a long duration interest and control of a resident entity in the home country (foreign direct investor or parent firm) in the host country. India has been one of the most translucent and open-minded FDI regimes among the emerging and developing economies. There is clear cut mentioned about the sectoral caps for foreign investment. The policy problems that have been identified by time to time surveys as acting as additional hurdles for FDI are laws, regulatory systems and government monopolies that do not have contemporary relevance. Foreign investment policies in the post-reforms period have emphasized greater encouragement and mobilization of non-debt creating private inflows for plunging reliance on debt flows. This paper will focus on how foreign direct investment policy changed from 1990-91 up to now. A time series data of 25 years is used for analysing the policy changes. It is observed that India has more liberal policy. The growth in number of Greenfield investments in India has been more impressive than the number of M&A deals whereas equity capital for incorporated bodies FDI inflows has been increased continuously 2014-15. India has made major changes in FDI Policy, and it has positive impact on economic development.Keywords: FDI, India, economic development, government
Procedia PDF Downloads 36220997 Emulation of a Wind Turbine Using Induction Motor Driven by Field Oriented Control
Authors: L. Benaaouinate, M. Khafallah, A. Martinez, A. Mesbahi, T. Bouragba
Abstract:
This paper concerns with the modeling, simulation, and emulation of a wind turbine emulator for standalone wind energy conversion systems. By using emulation system, we aim to reproduce the dynamic behavior of the wind turbine torque on the generator shaft: it provides the testing facilities to optimize generator control strategies in a controlled environment, without reliance on natural resources. The aerodynamic, mechanical, electrical models have been detailed as well as the control of pitch angle using Fuzzy Logic for horizontal axis wind turbines. The wind turbine emulator consists mainly of an induction motor with AC power drive with torque control. The control of the induction motor and the mathematical models of the wind turbine are designed with MATLAB/Simulink environment. The simulation results confirm the effectiveness of the induction motor control system and the functionality of the wind turbine emulator for providing all necessary parameters of the wind turbine system such as wind speed, output torque, power coefficient and tip speed ratio. The findings are of direct practical relevance.Keywords: electrical generator, induction motor drive, modeling, pitch angle control, real time control, renewable energy, wind turbine, wind turbine emulator
Procedia PDF Downloads 23520996 Implementation of a Predictive DTC-SVM of an Induction Motor
Authors: Chebaani Mohamed, Gplea Amar, Benchouia Mohamed Toufik
Abstract:
Direct torque control is characterized by the merits of fast response, simple structure and strong robustness to the motor parameters variations. This paper proposes the implementation of DTC-SVM of an induction motor drive using Predictive controller. The principle of the method is explained and the system mathematical description is provided. The derived control algorithm is implemented both in the simulation software MatLab/Simulink and on the real induction motor drive with dSPACE control system. Simulated and measured results in steady states and transients are presented.Keywords: induction motor, DTC-SVM, predictive controller, implementation, dSPACE, Matlab, Simulink
Procedia PDF Downloads 51920995 Model Predictive Control of Three Phase Inverter for PV Systems
Authors: Irtaza M. Syed, Kaamran Raahemifar
Abstract:
This paper presents a model predictive control (MPC) of a utility interactive three phase inverter (TPI) for a photovoltaic (PV) system at commercial level. The proposed model uses phase locked loop (PLL) to synchronize TPI with the power electric grid (PEG) and performs MPC control in a dq reference frame. TPI model consists of boost converter (BC), maximum power point tracking (MPPT) control, and a three leg voltage source inverter (VSI). Operational model of VSI is used to synthesize sinusoidal current and track the reference. Model is validated using a 35.7 kW PV system in Matlab/Simulink. Implementation and results show simplicity and accuracy, as well as reliability of the model.Keywords: model predictive control, three phase voltage source inverter, PV system, Matlab/simulink
Procedia PDF Downloads 59620994 Direct Translation vs. Pivot Language Translation for Persian-Spanish Low-Resourced Statistical Machine Translation System
Authors: Benyamin Ahmadnia, Javier Serrano
Abstract:
In this paper we compare two different approaches for translating from Persian to Spanish, as a language pair with scarce parallel corpus. The first approach involves direct transfer using an statistical machine translation system, which is available for this language pair. The second approach involves translation through English, as a pivot language, which has more translation resources and more advanced translation systems available. The results show that, it is possible to achieve better translation quality using English as a pivot language in either approach outperforms direct translation from Persian to Spanish. Our best result is the pivot system which scores higher than direct translation by (1.12) BLEU points.Keywords: statistical machine translation, direct translation approach, pivot language translation approach, parallel corpus
Procedia PDF Downloads 48820993 FLC with 3DSVM for 4LEG 4WIRE Shunt Active Power Filter
Authors: Abdelhalim Kessal, Ali Chebabhi
Abstract:
In this paper, a controller based on fuzzy logic control (FLC) associated to Three Dimensional Space Vector Modulation (3DSVM) is applied for shunt active filter in αβo axes domain. The main goals are to improve power quality under disturbed loads, minimize source currents harmonics and reduce neutral current magnitude in the four-wire structure. FLC is used to obtain the reference current and control the DC-bus voltage at the inverter output. The switching signals of the four-leg inverter are generating through a Three Dimensional Space Vector Modulation (3DSVM). Selected simulation results have been shown to validate the proposed system.Keywords: flc, 3dsvm, sapf, harmonic, inverter
Procedia PDF Downloads 49720992 Non-Contact Human Movement Monitoring Technique for Security Control System Based 2n Electrostatic Induction
Authors: Koichi Kurita
Abstract:
In this study, an effective non-contact technique for the detection of human physical activity is proposed. The technique is based on detecting the electrostatic induction current generated by the walking motion under non-contact and non-attached conditions. A theoretical model for the electrostatic induction current generated because of a change in the electric potential of the human body is proposed. By comparing the obtained electrostatic induction current with the theoretical model, it becomes obvious that this model effectively explains the behavior of the waveform of the electrostatic induction current. The normal walking motions are recorded using a portable sensor measurement located in a passageway of office building. The obtained results show that detailed information regarding physical activity such as a walking cycle can be estimated using our proposed technique. This suggests that the proposed technique which is based on the detection of the walking signal, can be successfully applied to the detection of human walking motion in a secured building.Keywords: human walking motion, access control, electrostatic induction, alarm monitoring
Procedia PDF Downloads 35720991 Right-Wing Narratives Associated with Cognitive Predictors of Radicalization: Direct User Engagement Drives Radicalization
Authors: Julius Brejohn Calvert
Abstract:
This Study Aimed to Investigate the Ecological Nature of Extremism Online. The Construction of a Far-Right Ecosystem Was Successful Using a Sample of Posts, Each With Separate Narrative Domains. Most of the Content Expressed Anti-black Racism and Pro-white Sentiments. Many Posts Expressed an Overt Disdain for the Recent Progress Made Regarding the United States and the United Kingdom’s Expansion of Civil Liberties to People of Color (Poc). Of Special Note, Several Anti-lgbt Posts Targeted the Ongoing Political Grievances Expressed by the Transgender Community. Overall, the Current Study Is Able to Demonstrate That Direct Measures of User Engagement, Such as Shares and Reactions, Can Be Used to Predict the Effect of a Post’s Radicalization Capabilities, Although Single Posts Do Not Operate on the Cognitive Processes of Radicalization Alone. In This Analysis, the Data Supports a Theoretical Framework Where Individual Posts Have a Higher Radicalization Capability Based on the Amount of User Engagement (Both Indirect and Direct) It Receives.Keywords: cognitive psychology, cognitive radicalization, extremism online, domestic extremism, political science, political psychology
Procedia PDF Downloads 7220990 Generalized Mathematical Description and Simulation of Grid-Tied Thyristor Converters
Authors: V. S. Klimash, Ye Min Thu
Abstract:
Thyristor rectifiers, inverters grid-tied, and AC voltage regulators are widely used in industry, and on electrified transport, they have a lot in common both in the power circuit and in the control system. They have a common mathematical structure and switching processes. At the same time, the rectifier, but the inverter units and thyristor regulators of alternating voltage are considered separately both theoretically and practically. They are written about in different books as completely different devices. The aim of this work is to combine them into one class based on the unity of the equations describing electromagnetic processes, and then, to show this unity on the mathematical model and experimental setup. Based on research from mathematics to the product, a conclusion is made about the methodology for the rapid conduct of research and experimental design work, preparation for production and serial production of converters with a unified bundle. In recent years, there has been a transition from thyristor circuits and transistor in modular design. Showing the example of thyristor rectifiers and AC voltage regulators, we can conclude that there is a unity of mathematical structures and grid-tied thyristor converters.Keywords: direct current, alternating current, rectifier, AC voltage regulator, generalized mathematical model
Procedia PDF Downloads 25020989 BLDC Motor Design Considering Core Loss Caused by Welding
Authors: Hyun-Seok Hong, In-Gun Kim, Ye-Jun Oh, Ju Lee
Abstract:
This paper deals with the effects of welding performed for the manufacture of laminations in a stator in the case of prototype motors that are manufactured in small quantity. As a result of performing the no-load test for an IPM (interior permanent magnet)-type BLDC (blushless direct current) motor manufactured by welding both inside and outside of the stator, it was found that more DC input than expected was provided. To verify the effects of welding, a stator was re-manufactured by bonding, and DC inputs provided during the no-load test were compared.Keywords: welding, stator, Eddy current, BLDC
Procedia PDF Downloads 56420988 Perspectives of Healthcare Workers on Healthcare-Associated Infections and Infection Control in a Tertiary Care Hospital in Abha, Saudi Arabia
Authors: Esther Paul, Ibrahim A. M. Alzaydani, Al Hakami, Caryl Beynon
Abstract:
Research Objectives and Goal: The main aim of the current study was to explore the perspectives of healthcare workers on Healthcare-associated infections (HAI) and infection control measures in a tertiary care Hospital in Abha, Saudi Arabia. As per our knowledge, this is perhaps the first qualitative study on HAI to be done in Saudi Arabia. The goal of the study was to understand the perspectives of the healthcare workers on the current protocol and guidelines for HAI and infections control measures in the hospital, the effectiveness of the current protocol for HAI and infection control measures and ways of reducing the incidence of HAI and improve infection control measures. Methods used: A qualitative research design was used to collect the data from 25 healthcare workers consisting of doctors and nurses, recruited by Snowball strategy via semi-structured interviews which were audio-recorded and transcribed verbatim immediately. An interview guide consisting of open-ended questions about the existing HAI and infection control practices in the healthcare facility, the awareness of the healthcare workers about HAI and the need for safe infection control measures were used to collect the data. The transcribed data were analyzed using the thematic analysis method. Results: Using thematic analysis four themes were identified.1.Knowledge of HAI and infection control 2. Infection control measures in practice 3. The gap in infection control measures and HAI 4. Required Implementations. The first theme covered the participants' knowledge on HAI, its definition, the types of HAI and the infection control measures.Most of the participants were aware of HAI and had some idea of the definition of HAI, its significance and the dangers posed by HAI, but few residents had no idea of the types of HAI. The second theme was focussed on the infection control measures in practice. Most of the participants were aware of the importance of infection control measures like hand hygiene, catheter care, and waste disposal. The nurses were responsible for most of the disinfection and sterilization measures and practiced it effectively. However, some doctors and residents had no inkling about these measures. The third theme emphasized that although most of the participants were aware of HAI and infection control measures and were in practice. There were some lacunae regarding their knowledge of the different types of HAI, Personal Protective Equipment practices, communication among the healthcare personnel and the hospital administrations and the means of waste disposal. The fourth and the final theme identified that most of the participants felt the need for implementations of changes regarding existing protocols, workshops/seminars, methods of waste disposal and sterilization and disinfection practices. Conclusion: The current qualitative study concluded that there is a need for better educational programs and hands-on training for all the healthcare personnel including the paramedical staff as well. The residents should have adequate knowledge of infection control practices to guide the nurses and should share the responsibility with the nurses in the practice of effective infection control measuresKeywords: healthcare-associated infections, infection control measures, perspectives, qualitative
Procedia PDF Downloads 21820987 Control of Chaotic Behaviour in Parallel-Connected DC-DC Buck-Boost Converters
Authors: Ammar Nimer Natsheh
Abstract:
Chaos control is used to design a controller that is able to eliminate the chaotic behaviour of nonlinear dynamic systems that experience such phenomena. The paper describes the control of the bifurcation behaviour of a parallel-connected DC-DC buck-boost converter used to provide an interface between energy storage batteries and photovoltaic (PV) arrays as renewable energy sources. The paper presents a delayed feedback control scheme in a module converter comprises two identical buck-boost circuits and operates in the continuous-current conduction mode (CCM). MATLAB/SIMULINK simulation results show the effectiveness and robustness of the scheme.Keywords: chaos, bifurcation, DC-DC Buck-Boost Converter, Delayed Feedback Control
Procedia PDF Downloads 43920986 Direct and Moderating Effect of Religious Activities, Sustainability and Peer Support on Job Performance
Authors: Fahad Alam
Abstract:
Work stress directly affects job performance, specifically in a worse environment. Consequently, a social provision plays a crucial part for enhancement. Therefore, the current research investigates the direct and moderating effect between religious activities, sustainability and peer support on job performance at hospitals in Khyber PakhtunKhwa (KPK), Pakistan. Both primary and secondary data are collected through 261 questionnaires of medical employees from four district hospitals in Khyber PakhtunKhwa, Pakistan, in 2018. The analysis was carried out by SPSS16 and SMART PLS3, to test the direct effect of religious activities, sustainability and social support on job performance and the effect of moderating variable 'work environment' on job performance. The finding confirmed that direct and moderating variables play a significant positive effect among religious activities, sustainability and peer support on job performance, the variables help to diminish the strain level or the stress level, consequently helps in the job completed. Affirmative social approaches produce desirable effects on job performance. The research revealed that social provisions are significant triggers for superior practices. Moreover, the results are stimulating because some of the past literature revealed an insignificant correlation between social provision and performance. This study found that there is a significant relationship which persuades health care organizations.Keywords: job performance, peer’s support, religious activities, sustainability, work environment
Procedia PDF Downloads 11620985 Neural Adaptive Controller for a Class of Nonlinear Pendulum Dynamical System
Authors: Mohammad Reza Rahimi Khoygani, Reza Ghasemi
Abstract:
In this paper, designing direct adaptive neural controller is applied for a class of a nonlinear pendulum dynamic system. The radial basis function (RBF) is used for the Neural network (NN). The adaptive neural controller is robust in presence of external and internal uncertainties. Both the effectiveness of the controller and robustness against disturbances are the merits of this paper. The promising performance of the proposed controllers investigates in simulation results.Keywords: adaptive control, pendulum dynamical system, nonlinear control, adaptive neural controller, nonlinear dynamical, neural network, RBF, driven pendulum, position control
Procedia PDF Downloads 67220984 Cyber Violence Behaviors Among Social Media Users in Ghana: An Application of Self-Control Theory and Social Learning Theory
Authors: Aisha Iddrisu
Abstract:
The proliferation of cyberviolence in the wave of increased social media consumption calls for immediate attention both at the local and global levels. With over 4.70 billion social media users worldwide and 8.8 social media users in Ghana, various forms of violence have become the order of the day in most countries and communities. Cyber violence is defined as producing, retrieving, and sharing of hurtful or dangerous online content to cause emotional, psychological, or physical harm. The urgency and severity of cyber violence have led to the enactment of laws in various countries though lots still need to be done, especially in Ghana. In Ghana, studies on cyber violence have not been extensively dealt with. Existing studies concentrate only on one form or the other form of cyber violence, thus cybercrime and cyber bullying. Also, most studies in Africa have not explored cyber violence forms using empirical theories and the few that existed were qualitatively researched, whereas others examine the effect of cyber violence rather than examining why those who involve in it behave the way they behave. It is against this backdrop that this study aims to examine various cyber violence behaviour among social media users in Ghana by applying the theory of Self-control and Social control theory. This study is important for the following reasons. The outcome of this research will help at both national and international level of policymaking by adding to the knowledge of understanding cyberviolence and why people engage in various forms of cyberviolence. It will also help expose other ways by which such behaviours are enforced thereby serving as a guide in the enactment of the rightful rules and laws to curb such behaviours. It will add to literature on consequences of new media. This study seeks to confirm or reject to the following research hypotheses. H1 Social media usage has direct significant effect of cyberviolence behaviours. H2 Ineffective parental management has direct significant positive relation to Low self-control. H3 Low self-control has direct significant positive effect on cyber violence behaviours among social, H4 Differential association has significant positive effect on cyberviolence behaviour among social media users in Ghana. H5 Definitions have a significant positive effect on cyberviolence behaviour among social media users in Ghana. H6 Imitation has a significant positive effect on cyberviolence behaviour among social media users in Ghana. H7 Differential reinforcement has a significant positive effect on cyberviolence behaviour among social media users in Ghana. H8 Differential association has a significant positive effect on definitions. H9 Differential association has a significant positive effect on imitation. H10 Differential association has a significant positive effect on differential reinforcement. H11 Differential association has significant indirect positive effects on cyberviolence through the learning process.Keywords: cyberviolence, social media users, self-control theory, social learning theory
Procedia PDF Downloads 8620983 Treatment of Oil Recovery Water Using Direct and Indirect Electrochemical Oxidation
Authors: Tareg Omar Mansour, Khaled Omar Elhaji
Abstract:
Model solutions of pentanol in the salt water of various concentrations were subjected to electrochemical oxidation using a dimensionally stable anode (DSA) and a platinised titanium cathode. The removal of pentanol was analysed over time using gas chromatography (GC) and by monitoring the total organic carbon (TOC) concentration of the reaction mixture. It was found that the removal of pentanol occurred more efficiently at higher salinities and higher applied electrical current values. When using a salt concentration of 20,000 ppm and an applied current of 100 mA there was a decrease in concentration of pentanol of 15 %. When the salt concentration and applied current were increased to 58,000 ppm and 500 mA respectively, the decrease in concentration was improved to 64 %.Keywords: dimensionally stable anode (DSA), total organic hydrocarbon (TOC), gas chromatography mass spectrometry (GCMS), electrochemical oxidation
Procedia PDF Downloads 384