Search results for: head and neck surgery
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2102

Search results for: head and neck surgery

1202 Support for Reporting Guidelines in Surgical Journals Needs Improvement: A Systematic Review

Authors: Riaz A. Agha, Ishani Barai, Shivanchan Rajmohan, Seon Lee, Mohammed O. Anwar, Alex J. Fowler, Dennis P. Orgill, Douglas G. Altman

Abstract:

Introduction: Medical knowledge is growing fast. Evidence-based medicine works best if the evidence is reported well. Past studies have shown reporting quality to be lacking in the field of surgery. Reporting guidelines are an important tool for authors to optimize the reporting of their research. The objective of this study was to analyse the frequency and strength of recommendation for such reporting guidelines within surgical journals. Methods: A systematic review of the 198 journals within the Journal Citation Report 2014 (surgery category) published by Thomson Reuters was undertaken. The online guide for authors for each journal was screened by two independent groups and results were compared. Data regarding the presence and strength of recommendation to use reporting guidelines was extracted. Results: 193 journals were included (as five appeared twice having changed their name). These had a median impact factor of 1.526 (range 0.047 to 8.327), with a median of 145 articles published per journal (range 29-659), with 34,036 articles published in total over the two-year window 2012-2013. The majority (62%) of surgical journals made no mention of reporting guidelines within their guidelines for authors. Of the journals (38%) that did mention them, only 14% (10/73) required the use of all relevant reporting guidelines. The most frequently mentioned reporting guideline was CONSORT (46 journals). Conclusion: The mention of reporting guidelines within the guide for authors of surgical journals needs improvement. Authors, reviewers and editors should work to ensure that research is reported in line with the relevant reporting guidelines. Journals should consider hard-wiring adherence to them. This will allow peer-reviewers to focus on what is present, not what is missing, raising the level of scholarly discourse between authors and the scientific community and reducing frustration amongst readers.

Keywords: CONSORT, guide for authors, PRISMA, reporting guidelines, journal impact factor, citation analysis

Procedia PDF Downloads 463
1201 Using Multi-Specialist Team to Care for a Breast Cancer Patient Who Received Total Mastectomy during Pregnancy

Authors: Yun-Tsuen Chen, Shih-Ting Huang, Pi-Fen Cheng, Heng-Hua Wang, Hui-Zhu Chen

Abstract:

This paper discusses the experience of caring for a patient diagnosed with breast cancer and later received total mastectomy during a 2nd trimester pregnancy. She was hospitalized from January 31 to February 4, 2018. Using 'Gordon’s 11 Functional Health Patterns' through physical exams and interviews, the researcher assessed the patient’s physical and mental health and determined the patient to have anxiety, acute pain, and body image disturbance. After establishing a strong relationship with the patient, the researcher helped the patient express her anxiety and personal feelings. A multi-specialist team was formed to evaluate both the patient and her unborn child, before, during, and after surgery. This individualized care allowed the patient and her child to optimize the post-operative results. Aside from medication, the patient also received non-medicinal treatment, including improvement of sleep quality with body positioning, diaphragmatic breathing exercises for pain and stress relief after surgery. Throughout hospitalization, the patient’s physical and emotional needs were addressed daily with listening sessions and empathy. The patient’s husband was also incorporated in the patient’s recovery by teaching both he and the patient how to change the sterile wound dressing, which may have the added benefit of improving marital relationships through shared activities of nurturing. The patient was also given advice about how to improve self-confidence through clothing. Lastly, the patient was encouraged to join a support group for breast cancer patients. Through the sharing of experience in groups and within the family, the patient was helped to adapt to the change of her appearance and re-establish her self-confidence. This level of care expedited the patient’s return to her family life and role of being a mother.

Keywords: anxiety, body image disturbance, breast cancer during pregnancy, multi-specialist team

Procedia PDF Downloads 96
1200 A Clinician’s Perspective on Electroencephalography Annotation and Analysis for Driver Drowsiness Estimation

Authors: Ruxandra Aursulesei, David O’Callaghan, Cian Ryan, Diarmaid O’Cualain, Viktor Varkarakis, Alina Sultana, Joseph Lemley

Abstract:

Human errors caused by drowsiness are among the leading causes of road accidents. Neurobiological research gives information about the electrical signals emitted by neurons firing within the brain. Electrical signal frequencies can be determined by attaching bio-sensors to the head surface. By observing the electrical impulses and the rhythmic interaction of neurons with each other, we can predict the mental state of a person. In this paper, we aim to better understand intersubject and intrasubject variability in terms of electrophysiological patterns that occur at the onset of drowsiness and their evolution with the decreasing of vigilance. The purpose is to lay the foundations for an algorithm that detects the onset of drowsiness before the physical signs become apparent.

Keywords: electroencephalography, drowsiness, ADAS, annotations, clinician

Procedia PDF Downloads 109
1199 Explantation of Osseo-Integrated Implant Using Electrosurgery and Ultrasonic Instrumentation

Authors: Stefano Andrea Denes

Abstract:

The use of dental implants to rehabilitate edentulous patients has become a well-established and effective treatment option; however, despite its high success rate, this treatment is not free of complications. The fracture of implant body is a rare cause of failure but when it does occur it can present technical challenges. In this article, we report the complete removal of a fractured osseointegrated implant using electrosurgery and ultrasonic instrumentation. The postoperative course was uneventful, no bleeding, infection, or hematoma formation was observed.

Keywords: dental implant, oral surgery, electrosurgery, piezosurgery

Procedia PDF Downloads 263
1198 Bioresorbable Medicament-Eluting Grommet Tube for Otitis Media with Effusion

Authors: Chee Wee Gan, Anthony Herr Cheun Ng, Yee Shan Wong, Subbu Venkatraman, Lynne Hsueh Yee Lim

Abstract:

Otitis media with effusion (OME) is the leading cause of hearing loss in children worldwide. Surgery to insert grommet tube into the eardrum is usually indicated for OME unresponsive to antimicrobial therapy. It is the most common surgery for children. However, current commercially available grommet tubes are non-bioresorbable, not drug-treated, with unpredictable duration of retention on the eardrum to ventilate middle ear. Their functionality is impaired when clogged or chronically infected, requiring additional surgery to remove/reinsert grommet tubes. We envisaged that a novel fully bioresorbable grommet tube with sustained antibiotic release technology could address these drawbacks. In this study, drug-loaded bioresorbable poly(L-lactide-co-ε-caprolactone)(PLC) copolymer grommet tubes were fabricated by microinjection moulding technique. In vitro drug release and degradation model of PLC tubes were studied. Antibacterial property was evaluated by incubating PLC tubes with P. aeruginosa broth. Surface morphology was analyzed using scanning electron microscopy. A preliminary animal study was conducted using guinea pigs as an in vivo model to evaluate PLC tubes with and without drug, with commercial Mini Shah grommet tube as comparison. Our in vitro data showed sustained drug release over 3 months. All PLC tubes revealed exponential degradation profiles over time. Modeling predicted loss of tube functionality in water to be approximately 14 weeks and 17 weeks for PLC with and without drug, respectively. Generally, PLC tubes had less bacteria adherence, which were attributed to the much smoother tube surfaces compared to Mini Shah. Antibiotic from PLC tube further made bacteria adherence on surface negligible. They showed neither inflammation nor otorrhea after 18 weeks post-insertion in the eardrums of guinea pigs, but had demonstrated severe degree of bioresorption. Histology confirmed the new PLC tubes were biocompatible. Analyses on the PLC tubes in the eardrums showed bioresorption profiles close to our in vitro degradation models. The bioresorbable antibiotic-loaded grommet tubes showed good predictability in functionality. The smooth surface and sustained release technology reduced the risk of tube infection. Tube functional duration of 18 weeks allowed sufficient ventilation period to treat OME. Our ongoing studies include modifying the surface properties with protein coating, optimizing the drug dosage in the tubes to enhance their performances, evaluating their functional outcome on hearing after full resoption of grommet tube and healing of eardrums, and developing animal model with OME to further validate our in vitro models.

Keywords: bioresorbable polymer, drug release, grommet tube, guinea pigs, otitis media with effusion

Procedia PDF Downloads 448
1197 Good Functional Outcome after Late Surgical Treatment for Traumatic Rotator Cuff Tear, a Retrospective Cohort Study

Authors: Soheila Zhaeentan, Anders Von Heijne, Elisabet Hagert, André Stark, Björn Salomonsson

Abstract:

Recommended treatment for traumatic rotator cuff tear (TRCT) is surgery within a few weeks after injury if the diagnosis is made early, especially if a functional impairment of the shoulder exists. This may lead to the assumption that a poor outcome then can be expected in delayed surgical treatment, when the patient is diagnosed at a later stage. The aim of this study was to investigate if a surgical repair later than three months after injury may result in successful outcomes and patient satisfaction. There is evidence in literature that good results of treatment can be expected up to three months after the injury, but little is known of later treatment with cuff repair. 73 patients (75 shoulders), 58 males/17 females, mean age 59 (range 34-­‐72), who had undergone surgical intervention for TRCT between January 1999 to December 2011 at our clinic, were included in this study. Patients were assessed by MRI investigation, clinical examination, Western Ontario Rotator Cuff index (WORC), Oxford Shoulder Score, Constant-­‐Murley Score, EQ-­‐5D and patient subjective satisfaction at follow-­‐up. The patients treated surgically within three months ( < 12 weeks) after injury (39 cases) were compared with patients treated more than three months ( ≥ 12 weeks) after injury (36 cases). WORC was used as the primary outcome measure and the other variables as secondary. A senior consultant radiologist, blinded to patient category and clinical outcome, evaluated all MRI-­‐images. Rotator cuff integrity, presence of arthritis, fatty degeneration and muscle atrophy was evaluated in all cases. The average follow-­‐up time was 56 months (range 14-­‐149) and the average time from injury to repair was 16 weeks (range 3-­‐104). No statistically significant differences were found for any of the assessed parameters or scores between the two groups. The mean WORC score was 77 (early group, range 25-­‐ 100 and late group, range 27-­‐100) for both groups (p= 0.86), Constant-­‐Murley Score (p= 0.91), Oxford Shoulder Score (p= 0.79), EQ-­‐5D index (p= 0.86). Re-­‐tear frequency was 24% for both groups, and the patients with re-­‐tear reported less satisfaction with outcome. Discussion and conclusion: This study shows that surgical repair of TRCT performed later than three months after injury may result in good functional outcomes and patient satisfaction. However, this does not motivate an intentional delay in surgery when there is an indication for surgical repair as that delay may adversely affect the possibility to perform a repair. Our results show that surgeons may safely consider surgical repair even if a delay in diagnosis has occurred. A retrospective cohort study on 75 shoulders shows good functional result after traumatic rotator cuff tear (TRCT) treated surgically up to one year after the injury.

Keywords: traumatic rotator cuff injury, time to surgery, surgical outcome, retrospective cohort study

Procedia PDF Downloads 219
1196 A Systematic Review of the Methodological and Reporting Quality of Case Series in Surgery

Authors: Riaz A. Agha, Alexander J. Fowler, Seon-Young Lee, Buket Gundogan, Katharine Whitehurst, Harkiran K. Sagoo, Kyung Jin Lee Jeong, Douglas G. Altman, Dennis P. Orgill

Abstract:

Introduction: Case Series are an important and common study type. Currently, no guideline exists for reporting case series and there is evidence of key data being missed from such reports. We propose to develop a reporting guideline for case series using a methodologically robust technique. The first step in this process is a systematic review of literature relevant to the reporting deficiencies of case series. Methods: A systematic review of methodological and reporting quality in surgical case series was performed. The electronic search strategy was developed by an information specialist and included MEDLINE, EMBASE, Cochrane Methods Register, Science Citation index and Conference Proceedings Citation index, from the start of indexing until 5th November 2014. Independent screening, eligibility assessments and data extraction was performed. Included articles were analyzed for five areas of deficiency: failure to use standardized definitions missing or selective data transparency or incomplete reporting whether alternate study designs were considered. Results: The database searching identified 2,205 records. Through the process of screening and eligibility assessments, 92 articles met inclusion criteria. Frequency of methodological and reporting issues identified was a failure to use standardized definitions (57%), missing or selective data (66%), transparency, or incomplete reporting (70%), whether alternate study designs were considered (11%) and other issues (52%). Conclusion: The methodological and reporting quality of surgical case series needs improvement. Our data shows that clear evidence-based guidelines for the conduct and reporting of a case series may be useful to those planning or conducting them.

Keywords: case series, reporting quality, surgery, systematic review

Procedia PDF Downloads 354
1195 Retrospective Audit of Antibiotic Prophylaxis in Spinal Patient at Mater Private Network Cork 2019 vs 2021

Authors: Ciaran Smiddy, Fergus Nugent, Karen Fitzmaurice

Abstract:

A measure of prescribing and administration of Antimicrobial Prophylaxis before and during Covid-19(2019 vs. 2021) was desired to assess how these were affected by Covid-19. Antimicrobial Prophylaxis was assessed for 60 patients, under 3 Orthopaedic Consultants, against local guidelines. The study found that compliance with guidelines improved significantly, from 60% to 83%, but Appropriate use of Vancomycin reduced from 37% to 29%.

Keywords: antimicrobial stewardship, prescribing, spinal surgery, vancomycin

Procedia PDF Downloads 168
1194 Analysis of Collision Avoidance System

Authors: N. Gayathri Devi, K. Batri

Abstract:

The advent of technology has increased the traffic hazards and the road accidents take place. Collision detection system in automobile aims at reducing or mitigating the severity of an accident. This project aims at avoiding Vehicle head on collision by means of collision detection algorithm. This collision detection algorithm predicts the collision and the avoidance or minimization have to be done within few seconds on confirmation. Under critical situation collision minimization is made possible by turning the vehicle to the desired turn radius so that collision impact can be reduced. In order to avoid the collision completely, the turning of the vehicle should be achieved at reduced speed in order to maintain the stability.

Keywords: collision avoidance system, time to collision, time to turn, turn radius

Procedia PDF Downloads 543
1193 Comparative Evaluation of Pentazocine and Tramadol as Pre-Emptive Analgesics for Ovariohysterectomy in Female Dogs

Authors: Venkatgiri, Ranganath, L. Nagaraja, B. N. Sagar Pandav, S. M. Usturge, D. Dilipkumar, B. V. Shivprakash, B. Bhagwanthappa, D. Jahangir

Abstract:

A comparative evaluation of Tramadol and Pentazocine as a pre-emptive analgesic in clinical cases of female dogs undergoing ovariohysterectomy was undertaken during this study. During the study, the following parameters were assessed viz., Rectal temperature (ᵒF), Respiratory rate (breaths/min) and Heart rate (beats/min). Hematological and biochemical parameters viz., total erythrocyte count (TEC) (millions/cmm), hemoglobin (g %), otal leucocytes count (TLC) (thousands/cmm), differential leucocytes count (DLC) (%), serum creatinine (mg/dl), plasma protein (mg/dl), blood glucose (mg/dl) was estimated before the surgery and after administration of general anaesthesia and immediate postoperative periods of 0, 12 and 24 hr respectively. Mean Total Pain Score (MTPS) includes measurement of parameters like posture, vocalization, activity level, response to palpation and agitation at different intervals was calculated before surgery and after administration of general anesthesia and post-operative periods of 1, 2, 4, 6, 12hrs and 24 hrs respectively. Mean Total Pain Score (MTPS) was given for each parameter (Posture, Vocalization, Activity Level, Response to Palpation and Agitation) like 0,1,2,3. (maximum score will be given was 4.). Results were revealed in all three groups including control group. There were significant minor alterations in physiological, hematological and biochemical parameters. MTPS (mean total pain score) were revealed and found a significant alteration when compared with control group. In conclusion, Tramadol found to be a better analgesic and had up to 8hrs of analgesic effect and Pentazocine is superior in post-operative pain management when compared to Tramadol because this group of dogs experienced less surgical stress, consumed less anesthetic dose, they recovered early, and they had less MTPS score.

Keywords: dog, pentazocine, tramadol, ovariohysterectomy

Procedia PDF Downloads 161
1192 A Perspective on Emergency Care of Gunshot Injuries in Northern Taiwan

Authors: Liong-Rung Liu, Yu-Hui Chiu, Wen-Han Chang

Abstract:

Firearm injuries are high-energy injuries. The ballistic pathways could cause severe burns or chemical damages to vessels, musculoskeletal or other major organs. The high mortality rate is accompanied by complications such as sepsis. As laws prohibit gun possession, civilian gunshot wounds (GSW) are relatively rare in Taiwan. Our hospital, Mackay Memorial Hospital, located at the center of Taipei city is surrounded by nightclubs and red-light districts. Due to this unique location, our hospital becomes the first-line trauma center managing gunshot victims in Taiwan. To author’s best knowledge, there are few published research articles regarding this unique situation. We hereby analyze the distinct characteristics and length of stay (LOS) of GSW patients in the emergency room (ER) at Mackay Memorial Hospital. A 6-year retrospective analysis of 27 patients treated for GSW injuries from January 2012 to December 2017 was performed. The patients’ records were reviewed for the following analyses, 1) wound position and the correlated clinical presentations; 2) the LOS in ED of patients receiving emergency surgery for major organ or vascular injuries. We found males (96.3%) were injured by guns more often than females (3.7%) in all age groups. The most common injured site was in the extremities. With regards to the ER LOS, the average time were 72.2 ± 34.5 minutes for patients with triage I and 207.4 ± 143.9 minutes for patients with triage II. The ED LOS of patients whose ISS score were more than 15 was 59.9 ± 25.6 minutes, and 179.4 ± 119.8 minutes for patients whose ISS score were between 9 to 15, respectively. Among these 27 patients, 10 patients had emergency surgery and their average ED stay time was 104.5 ± 33.3 minutes. Even more, the average ED stay time could be shortened to 88.8 ± 32.3 minutes in the 5 patients with trauma team activation. In conclusion, trauma team activation in severe GSW patients indeed shortens the ED LOS and might initially improve the quality of patient care. This is the result of better trauma systems, including advances in care from emergency medical services and acute care surgical management.

Keywords: gunshot, length of stay, trauma, mortality

Procedia PDF Downloads 130
1191 The Effectiveness of Laser In situ Keratomileusis for Correction Various Types of Refractive Anomalies

Authors: Yuliya Markava

Abstract:

The laser in situ keratomileusis (LASIK) is widely common surgical procedure, which has become an alternative for patients who are not satisfied with the performance of other correction methods. A high level of patient satisfaction functional outcomes after refractive surgery confirms the high reliability and safety of LASIK and provides a significant improvement in the quality of life and social adaptation. Purpose: To perform clinical analysis of the results of correction made to the excimer laser system SCHWIND AMARIS 500E in patients with different types of refractive anomalies. Materials and Methods: This was a retrospective analysis of 1581 operations (812 patients): 413 males (50.86%) and 399 females (49.14%) at the age from 18 to 47 years with different types of ametropia. All operations were performed on excimer laser SCHWIND AMARIS 500E in the LASIK procedure. Formation of the corneal flap was made by mechanical microkeratome SCHWIND. Results: Analyzing the structure of refractive anomalies: The largest number of interventions accounted for myopia: 1505 eyes (95.2%), of which about a low myopia: 706 eyes (44.7%), moderate myopia: 562 eyes (35.5 %), high myopia: eyes 217 (13.7%) and supermyopia: 20 eyes (1.3%). Hyperopia was 0.7% (11 eyes), mixed astigmatism: 4.1% (65 eyes). The efficiency was 80% (in patients with supermyopia) to 91.6% and 95.4% (in groups with myopia low and moderate, respectively). Uncorrected visual acuity average values before and after laser operation was in groups: a low myopia 0.18 (up 0.05 to 0.31) and 0.80 (up 0.60 to 1.0); moderate myopia 0.08 (up 0.03 to 0.13) and 0.87 ( up 0.74 to 1.0); high myopia 0.05 (up 0.02 to 0.08) and 0.83 (up 0.66 to 1.0); supermyopia 0.03 (up 0.02 to 0.04) and 0.59 ( up 0.34 to 0.84); hyperopia 0.27 (up 0.16 to 0.38) and 0.57 (up 0.27 to 0.87); mixed astigmatism of 0.35 (up 0.19 to 0.51) and 0.69 (up 0.44 to 0.94). In all cases, after LASIK indicators uncorrected visual acuity significantly increased. Reoperation was 4.43%. Significance: Clinical results of refractive surgery at the excimer laser system SCHWIND AMARIS 500E in different ametropia correction is characterized by high efficiency.

Keywords: effectiveness of laser correction, LASIK, refractive anomalies, surgical treatment

Procedia PDF Downloads 249
1190 Aerodynamic Effects of Ice and Its Influences on Flight Characteristics of Low Speed Unmanned Aerial Vehicles

Authors: I. McAndrew, K. L. Witcher, E. Navarro

Abstract:

This paper presents the theory and application of low-speed flight for unmanned aerial vehicles when subjected to surface environmental conditions such as ice on the leading edge and upper surface. A model was developed and tested in a wind tunnel to see how theory compares with practice at various speed including take-off, landing and operational applications where head winds substantially alter parameters. Furthermore, a comparison is drawn with maned operations and how that this subject is currently under-supported with accurate theory or knowledge for designers or operators to make informed decision or accommodate individual applications. The effects of ice formation for lift and drag are determined for a range of different angles of attacks.

Keywords: aerodynamics, environmental influences, glide path ratio, unmanned vehicles

Procedia PDF Downloads 325
1189 Model Development for Real-Time Human Sitting Posture Detection Using a Camera

Authors: Jheanel E. Estrada, Larry A. Vea

Abstract:

This study developed model to detect proper/improper sitting posture using the built in web camera which detects the upper body points’ location and distances (chin, manubrium and acromion process). It also established relationships of human body frames and proper sitting posture. The models were developed by training some well-known classifiers such as KNN, SVM, MLP, and Decision Tree using the data collected from 60 students of different body frames. Decision Tree classifier demonstrated the most promising model performance with an accuracy of 95.35% and a kappa of 0.907 for head and shoulder posture. Results also showed that there were relationships between body frame and posture through Body Mass Index.

Keywords: posture, spinal points, gyroscope, image processing, ergonomics

Procedia PDF Downloads 325
1188 TopClosure® of Large Abdominal Wall Defect Instead of Staged Hernia Repair as Part of Damage Control Laparotomy

Authors: Andriy Fedorenko

Abstract:

Background Early closure of the open abdomen is a priority after damage control laparotomy to prevent retraction of fascial layers and prevent hernia formation that requires definitive repair at a later stage. This substantially reduces the complications associated with ventral hernia formation for up to a year after initial surgery. TopClosure® is an innovative method that employs stress-relaxation and mechanical creep for skin stretching. Its use enables the primary closure of large abdominal wall defects and mitigates large ventral hernia formation. Materials and Methods A 7-year-old girl presented with severe blast injury. She underwent initial laparotomy in a facility within the conflict zone and was transferred in a state of septic shock to our facility for further care. Her abdominal injuries included liver lacerations, multiple perforations of the transverse colon and ileum, and a 8x16cm oblique abdominal wall defect. Further damage control laparotomy was performed with primary suture of the colon and ileum and temporary closure of the abdomen using a Bagota bag. Twelve hours later, negative pressure wound therapy (NPWT) was applied to the abdominal wound after relook laparotomy. Five days later, TopClosure® was applied to the lower part of the wound incorporating NPWT to the upper wound. Results The patient suffered leak from the colonic suture line and required relaparotomy. TopClosure® abdominal closure was achieved after every laparotomy. Conclusion TopClosure® utilizes the viscoelastic properties of the skin achieving full closure of the abdominal wall (including the fascia and skin),eliminating the need for prolonged NPWT, skin graft, and delayed ventral hernia repair surgery.

Keywords: topclosure, abdominal wall defect, hernia, damage control

Procedia PDF Downloads 74
1187 [Keynote Talk]: Aerodynamic Effects of Ice and Its Influences on Flight Characteristics of Low Speed Unmanned Aerial Vehicles

Authors: I. McAndrew, K. L. Witcher, E. Navarro

Abstract:

This paper presents the theory and application of low speed flight for unmanned aerial vehicles when subjected to surface environmental conditions such as ice on the leading edge and upper surface. A model was developed and tested in a wind tunnel to see how theory compares with practice at various speed including take-off, landing and operational applications where head winds substantially alter parameters. Furthermore, a comparison is drawn with maned operations and how that this subject is currently under supported with accurate theory or knowledge for designers or operators to make informed decision or accommodate individual applications. The effects of ice formation for lift and drag are determined for a range of different angles of attacks.

Keywords: aerodynamics, low speed flight, unmanned vehicles, environmental influences

Procedia PDF Downloads 436
1186 Effect of Lullabies on Babies Growth and Development, Vital Signs and Hospitalization Times in the Neonatal Intensive Care Units

Authors: Işın Alkan, Meltem Kürtüncü

Abstract:

Objective: This study was carried out with an experimental design in order to determine whether the lullaby, which was listened from mother’s voice and a stranger’s voice to the babies born at term and hospitalized in neonatal intensive care unit, had an effect on saturation values (SpO2), peak heart rate (PHR), respiration, fever, growth and development and hospitalization times of the infants. Method: Data from the study were obtained from 90 newborn babies who were hospitalized in Neonatal Intensive Care Unit of Zonguldak Maternity And Children Hospital between September 2015-January 2016 and who met the eligibility criteria. Lullaby concert was performed by choosing one of the suitable care hours. SpO2, PHR, respiration, fever, growth and development and hospitalization times of the infants were recorded by the researcher on “Newborn response follow-up form” at pre-care and post-care. Vital signs of babies every day, weight, height and head circumference measurements at admission, weakly rated at an output. Results: In the experimental and control groups, like weight, height and head circumference anthropometric measurements were not found statistically significant difference intensive care units admission and output times. Hospitalization times on babies who listen to lullaby mother’s voice revealed statistically significant difference according to babies who listen to lullaby stranger’s voice. Before care and after care were examined, SpO2 rates of babies who listen to lullaby mother’s voice revealed statistically significant higher difference according to babies who listen to lullaby stranger’s voice and control group babies. Before care on PHR of babies in three groups were not found the statistical difference, but aftercare, it was found that statistically lower (normal range) on babies who listen to lullaby mother’s voice according to babies who listen to lullaby stranger’s voice. Before care in three groups were not found the statistical difference on respiration values of babies, but aftercare, it was found that statistically lower (normal range) on babies who listen to lullaby stranger’s voice according to babies who listen to mother’s voice and control groups. Before care and after care were examined, fever signs did not reveal statistically significant difference in three groups. Conclusion: Lullaby concerts as being normal ranges of vital signs of infants and also helping to shorten hospitalization times should be preferred in the neonatal intensive care units.

Keywords: growth and development, lullaby, mother voice, vital signs

Procedia PDF Downloads 211
1185 Resource Assessment of Animal Dung for Power Generation: A Case Study

Authors: Gagandeep Kaur, Yadwinder Singh Brar, D. P. Kothari

Abstract:

The paper has an aggregate analysis of animal dung for converting it into renewable biomass fuel source that could be used to help the Indian state Punjab to meet rising power demand. In Punjab district Bathinda produces over 4567 tonnes of animal dung daily on a renewable basis. The biogas energy potential has been calculated using values for the daily per head animal dung production and total no. of large animals in Bathinda of Punjab. The 379540 no. of animals in district could produce nearly 116918 m3 /day of biogas as renewable energy. By converting this biogas into electric energy could produce 89.8 Gwh energy annually.

Keywords: livestock, animal dung, biogas, renewable energy

Procedia PDF Downloads 504
1184 Signals Monitored during Anaesthesia

Authors: Launcelot.McGrath

Abstract:

A comprehensive understanding of physiological data is a vital aid to the anaesthesiologist in monitoring and maintaining the well-being of a patient undergoing surgery. Biosignal analysis is one of the most important topics that researchers have tried to develop over the last century to understand numerous human diseases. Understanding which biological signals are most important during anaesthesia is critically important. It is important that the anaesthesiologist understand both the signals themselves and the limitations introduced by the processes of acquisition. In this article, we provide an overview of different types of biological signals as well as the mechanisms applied to acquire them.

Keywords: general biosignals, anaesthesia, biological, electroencephalogram

Procedia PDF Downloads 141
1183 Real-Time Fitness Monitoring with MediaPipe

Authors: Chandra Prayaga, Lakshmi Prayaga, Aaron Wade, Kyle Rank, Gopi Shankar Mallu, Sri Satya, Harsha Pola

Abstract:

In today's tech-driven world, where connectivity shapes our daily lives, maintaining physical and emotional health is crucial. Athletic trainers play a vital role in optimizing athletes' performance and preventing injuries. However, a shortage of trainers impacts the quality of care. This study introduces a vision-based exercise monitoring system leveraging Google's MediaPipe library for precise tracking of bicep curl exercises and simultaneous posture monitoring. We propose a three-stage methodology: landmark detection, side detection, and angle computation. Our system calculates angles at the elbow, wrist, neck, and torso to assess exercise form. Experimental results demonstrate the system's effectiveness in distinguishing between good and partial repetitions and evaluating body posture during exercises, providing real-time feedback for precise fitness monitoring.

Keywords: physical health, athletic trainers, fitness monitoring, technology driven solutions, Google’s MediaPipe, landmark detection, angle computation, real-time feedback

Procedia PDF Downloads 62
1182 Care: A Cluster Based Approach for Reliable and Efficient Routing Protocol in Wireless Sensor Networks

Authors: K. Prasanth, S. Hafeezullah Khan, B. Haribalakrishnan, D. Arun, S. Jayapriya, S. Dhivya, N. Vijayarangan

Abstract:

The main goal of our approach is to find the optimum positions for the sensor nodes, reinforcing the communications in points where certain lack of connectivity is found. Routing is the major problem in sensor network’s data transfer between nodes. We are going to provide an efficient routing technique to make data signal transfer to reach the base station soon without any interruption. Clustering and routing are the two important key factors to be considered in case of WSN. To carry out the communication from the nodes to their cluster head, we propose a parameterizable protocol so that the developer can indicate if the routing has to be sensitive to either the link quality of the nodes or the their battery levels.

Keywords: clusters, routing, wireless sensor networks, three phases, sensor networks

Procedia PDF Downloads 502
1181 Estimation of Rock Strength from Diamond Drilling

Authors: Hing Hao Chan, Thomas Richard, Masood Mostofi

Abstract:

The mining industry relies on an estimate of rock strength at several stages of a mine life cycle: mining (excavating, blasting, tunnelling) and processing (crushing and grinding), both very energy-intensive activities. An effective comminution design that can yield significant dividends often requires a reliable estimate of the material rock strength. Common laboratory tests such as rod, ball mill, and uniaxial compressive strength share common shortcomings such as time, sample preparation, bias in plug selection cost, repeatability, and sample amount to ensure reliable estimates. In this paper, the authors present a methodology to derive an estimate of the rock strength from drilling data recorded while coring with a diamond core head. The work presented in this paper builds on a phenomenological model of the bit-rock interface proposed by Franca et al. (2015) and is inspired by the now well-established use of the scratch test with PDC (Polycrystalline Diamond Compact) cutter to derive the rock uniaxial compressive strength. The first part of the paper introduces the phenomenological model of the bit-rock interface for a diamond core head that relates the forces acting on the drill bit (torque, axial thrust) to the bit kinematic variables (rate of penetration and angular velocity) and introduces the intrinsic specific energy or the energy required to drill a unit volume of rock for an ideally sharp drilling tool (meaning ideally sharp diamonds and no contact between the bit matrix and rock debris) that is found well correlated to the rock uniaxial compressive strength for PDC and roller cone bits. The second part describes the laboratory drill rig, the experimental procedure that is tailored to minimize the effect of diamond polishing over the duration of the experiments, and the step-by-step methodology to derive the intrinsic specific energy from the recorded data. The third section presents the results and shows that the intrinsic specific energy correlates well to the uniaxial compressive strength for the 11 tested rock materials (7 sedimentary and 4 igneous rocks). The last section discusses best drilling practices and a method to estimate the rock strength from field drilling data considering the compliance of the drill string and frictional losses along the borehole. The approach is illustrated with a case study from drilling data recorded while drilling an exploration well in Australia.

Keywords: bit-rock interaction, drilling experiment, impregnated diamond drilling, uniaxial compressive strength

Procedia PDF Downloads 132
1180 Effectiveness of Using Multiple Non-pharmacological Interventions to Prevent Delirium in the Hospitalized Elderly

Authors: Yi Shan Cheng, Ya Hui Yeh, Hsiao Wen Hsu

Abstract:

Delirium is an acute state of confusion, which is mainly the result of the interaction of many factors, including: age>65 years, comorbidity, cognitive function and visual/auditory impairment, dehydration, pain, sleep disorder, pipeline retention, general anesthesia and major surgery… etc. Researches show the prevalence of delirium in hospitalized elderly patients over 50%. If it doesn't improve in time, may cause cognitive decline or impairment, not only prolong the length of hospital stay but also increase mortality. Some studies have shown that multiple nonpharmacological interventions are the most effective and common strategies, which are reorientation, early mobility, promoting sleep and nutritional support (including water intake), could improve or prevent delirium in the hospitalized elderly. In Taiwan, only one research to compare the delirium incidence of the older patients who have received orthopedic surgery between multi-nonpharmacological interventions and general routine care. Therefore, the purpose of this study is to address the prevention or improvement of delirium incidence density in medical hospitalized elderly, provide clinical nurses as a reference for clinical implementation, and develop follow-up related research. This study is a quasi-experimental design using purposive sampling. Samples are from two wards: the geriatric ward and the general medicine ward at a medical center in central Taiwan. The sample size estimated at least 100, and then the data will be collected through a self-administered structured questionnaire, including: demographic and professional evaluation items. Case recruiting from 5/13/2023. The research results will be analyzed by SPSS for Windows 22.0 software, including descriptive statistics and inferential statistics: logistic regression、Generalized Estimating Equation(GEE)、multivariate analysis of variance(MANOVA).

Keywords: multiple nonpharmacological interventions, hospitalized elderly, delirium incidence, delirium

Procedia PDF Downloads 76
1179 MR-Implantology: Exploring the Use for Mixed Reality in Dentistry Education

Authors: Areej R. Banjar, Abraham G. Campbell

Abstract:

The use of Mixed Reality (MR) in teaching and training is growing popular and can improve students’ ability to perform technical procedures. This short paper outlines the creation of an interactive educational MR 3D application that aims to improve the quality of instruction for dentistry students. This application is called MRImplantology and aims to teach the fundamentals and preoperative planning of dental implant placement. MRImplantology uses cone-beam computed tomography (CBCT) images as the source for 3D dental models that dentistry students will be able to freely manipulate within a 3D MR world to aid their learning process.

Keywords: augmented reality, education, dentistry, cone-beam computed tomography CBCT, head mounted display HMD, mixed reality

Procedia PDF Downloads 183
1178 Fuzzy Rules Based Improved BEENISH Protocol for Wireless Sensor Networks

Authors: Rishabh Sharma

Abstract:

The main design parameter of WSN (wireless sensor network) is the energy consumption. To compensate this parameter, hierarchical clustering is a technique that assists in extending duration of the networks life by efficiently consuming the energy. This paper focuses on dealing with the WSNs and the FIS (fuzzy interface system) which are deployed to enhance the BEENISH protocol. The node energy, mobility, pause time and density are considered for the selection of CH (cluster head). The simulation outcomes exhibited that the projected system outperforms the traditional system with regard to the energy utilization and number of packets transmitted to sink.

Keywords: wireless sensor network, sink, sensor node, routing protocol, fuzzy rule, fuzzy inference system

Procedia PDF Downloads 100
1177 Performance Analysis of ERA Using Fuzzy Logic in Wireless Sensor Network

Authors: Kamalpreet Kaur, Harjit Pal Singh, Vikas Khullar

Abstract:

In Wireless Sensor Network (WSN), the main limitation is generally inimitable energy consumption during processing of the sensor nodes. Cluster head (CH) election is one of the main issues that can reduce the energy consumption. Therefore, discovering energy saving routing protocol is the focused area for research. In this paper, fuzzy-based energy aware routing protocol is presented, which enhances the stability and network lifetime of the network. Fuzzy logic ensures the well-organized selection of CH by taking four linguistic variables that are concentration, energy, centrality, and distance to base station (BS). The results show that the proposed protocol shows better results in requisites of stability and throughput of the network.

Keywords: ERA, fuzzy logic, network model, WSN

Procedia PDF Downloads 274
1176 Economics and Management Information Systems: Institute of Management and Technology Enugu a Case Study

Authors: Cletus Agbowo

Abstract:

Standard principles, rules, regulations, norms and guides are necessities in practice especially in the Economics and management information system Institute of management of and technology (IMT) Enugu a case sturdy as presented by the presenter. Without mincing words, the fundamental bottle neck of management is economics, how to select to engage merger productivity resources to achieve uncountable objectives without tears. Management information system inevitably become bound up in organizational politics because the influence access to a key resource – namely information. Economics and management information can effect who does what to whom, when, where and how in an organization. In great institutions like the Institute of Management and Technology (IMT) Enugu a case study many new information systems require changes in personnel, individual routines that can be painful for those involved and require retraining and additional effort may or may not be compensated. In a nut shell, because management information system potentially change an organization’s structure, culture, business processes, and strategy, there is often considerable resistance to them when they are introduced. The case study have many schools, departments, divisions and units which needs research on economics and management information systems. A system can be defined as a set of interrelated components and / or elements, which reacts with input to produce output. A department in an organization is a system. The researcher is faced to itemize the practical challenges encountered and solution adopted by the Institute Management and Enugu state government.

Keywords: economics, information, management, productivity, regulations

Procedia PDF Downloads 374
1175 Numerical Solution of 1-D Shallow Water Equations at Junction for Sub-Critical and Super-Critical Flow

Authors: Mohamed Elshobaki, Alessandro Valiani, Valerio Caleffi

Abstract:

In this paper, we solve 1-D shallow water equation for sub-critical and super-critical water flow at junction. The water flow at junction has been studied for the last 50 years from the physical-hydraulic point of views and for numerical computations need more attention. For numerical simulation, we need to establish an inner boundary condition at the junction to avoid an oscillation which rise from the waves interactions at the junction. Indeed, we introduce a new boundary condition at the junction based on the mass conservation, total head, and the admissible wave relations between the flow parameters in the three branches to predict the water depths and discharges at the junction. These boundary conditions are valid for sub-critical flow and super-critical flow.

Keywords: numerical simulation, junction flow, sub-critical flow, super-critical flow

Procedia PDF Downloads 504
1174 Enhancement of Environmental Security by the Application of Wireless Sensor Network in Nigeria

Authors: Ahmadu Girgiri, Lawan Gana Ali, Mamman M. Baba

Abstract:

Environmental security clearly articulates the perfections and developments of various communities around the world irrespective of the region, culture, religion or social inclination. Although, the present state of insecurity has become serious issue devastating the peace, unity, stability and progress of man and his physical environment particularly in developing countries. Recently, measure of security and it management in Nigeria has been a bottle-neck to the effectiveness and advancement of various sectors that include; business, education, social relations, politics and above all an economy. Several measures have been considered on mitigating environment insecurity such as surveillance, demarcation, security personnel empowerment and the likes, but still the issue remains disturbing. In this paper, we present the application of new technology that contributes to the improvement of security surveillance known as “Wireless Sensor Network (WSN)”. The system is new, smart and emerging technology that provides monitoring, detection and aggregation of information using sensor nodes and wireless network. WSN detects, monitors and stores information or activities in the deployed area such as schools, environment, business centers, public squares, industries, and outskirts and transmit to end users. This will reduce the cost of security funding and eases security surveillance depending on the nature and the requirement of the deployment.

Keywords: application, environment, insecurity, sensor, wireless sensor network

Procedia PDF Downloads 256
1173 Cup-Cage Construct for Treatment of Severe Acetabular Bone Loss in Revision Total Hip Arthroplasty: Midterm Clinical and Radiographic Outcomes

Authors: Faran Chaudhry, Anser Daud, Doris Braunstein, Oleg Safir, Allan Gross, Paul Kuzyk

Abstract:

Background: Acetabular reconstruction in the context of massive acetabular bone loss is challenging. In rare scenarios where the extent of bone loss precludes shell placement (cup-cage), reconstruction at our center consisted of a cage combined with highly porous metal augments. This study evaluates survivorship, complications, and functional outcomes using this technique. Methods: A total of 131 cup-cage implants (129 patients) were included in our retrospective review of revisions of total hip arthroplasty from January 2003 to January 2022. Among these cases, 100/131 (76.3%) were women, the mean age at surgery time was 68.7 years (range, 29.0 to 92.0; SD, 12.4), and the mean follow-up was 7.7 years (range, 0.02 to 20.3; SD, 5.1). Kaplan-Meier survivorship analysis was conducted with failure defined as revision surgery and/or failure of the cup-cage reconstruction. Results: A total of 30 implants (23%) reached the study endpoint involving all-cause revision. Overall survivorship was 74.8% at 10 years and 69.8% at 15 years. Reasons for revision included infection 12/131 (9.1%), dislocation 10/131 (7.6%), aseptic loosening of cup and/or cage 5/131 (3.8%), and aseptic loosening of the femoral stem 2/131 (1.5%). The mean LLD improved from 12.2 ± 15.9 mm to 3.9 ± 11.8 (p<0.05). The horizontal and vertical hip centres on plain film radiographs were significantly improved (p<0.05). Functionally, there was a decrease in the number of patients requiring the use of gait aids, with fewer patients (34, 25.9%) using a cane, walker, or wheelchair post-operatively compared to pre-operatively (58, 44%). There was a significant increase in the number of independent ambulators from 24 to 47 (36%). Conclusion: The cup-cage construct is a reliable treatment option for the treatment of various acetabular defects. There are favourable survivorship, clinical and radiographic outcomes, with a satisfactory complication rate.

Keywords: revision total hip arthroplasty, acetabular defect, pelvic discontinuity, trabecular metal augment, cup-cage

Procedia PDF Downloads 64