Search results for: 66 acupoints under human elbow and knee
8591 Correlation Study between Clinical and Radiological Findings in Knee Osteoarthritis
Authors: Nabil A. A. Mohamed, Alaa A. A. Balbaa, Khaled E. Ayad
Abstract:
Osteoarthritis (OA) of the knee is the most common form of arthritis and leads to more activity limitations (e.g., disability in walking and stair climbing) than any other disease, especially in the elderly. Recently, impaired proprioceptive accuracy of the knee has been proposed as a local factor in the onset and progression of radiographic knee OA (ROA). Purpose: To compare the clinical and radiological findings in healthy with that of knee OA. Also, to determine if there is a correlation between the clinical and radiological findings in patients with knee OA. Subjects: Fifty one patients diagnosed as unilateral or bilateral knee OA with age ranged between 35-70 years, from both gender without any previous history of knee trauma or surgery, and twenty one normal subjects with age ranged from 35 - 68 years. METHODS: peak torque/body weight (PT/BW) was recorded from knee extensors at isokinetic isometric mode at angle of 45 degree. Also, the Absolute Angular Error was recorded at 45O and 30O to measure joint position sense (JPS). They made anteroposterior (AP) plain X-rays from standing semiflexed knee position and their average score of Timed Up and Go test(TUG) and WOMAC were recorded as a measure of knee pain, stiffness and function. Comparison between the mean values of different variables in the two groups was performed using unpaired student t test. The P value less or equal to 0.05 was considered significant. Results: There were significant differences between the studied variables between the experimental and control groups except the values of AAE at 30O. Also, there were no significant correlation between the clinical findings (pain, function, muscle strength and proprioception) and the severity of arthritic changes in X-rays. CONCLUSION: From the finding of the current study we can conclude that there were a significant difference between the both groups in all studied parameters (the WOMAC, functional level, quadriceps muscle strength and the joint proprioception). Also this study did not support the dependency on radiological findings in management of knee OA as the radiological features did not necessarily indicate the level of structural damage of patients with knee OA and we should consider the clinical features in our treatment plan.Keywords: joint position sense, peak torque, proprioception, radiological knee osteoarthritis
Procedia PDF Downloads 3028590 Prevalence of Work-Related Musculoskeletal Disorder among Dental Personnel in Perak
Authors: Nursyafiq Ali Shibramulisi, Nor Farah Fauzi, Nur Azniza Zawin Anuar, Nurul Atikah Azmi, Janice Hew Pei Fang
Abstract:
Background: Work related musculoskeletal disorders (WRMD) among dental personnel have been underestimated and under-reported worldwide and specifically in Malaysia. The problem will arise and progress slowly over time, as it results from accumulated injury throughout the period of work. Several risk factors, such as repetitive movement, static posture, vibration, and adapting poor working postures, have been identified to be contributing to WRMSD in dental practices. Dental personnel is at higher risk of getting this problem as it is their working nature and core business. This would cause pain and dysfunction syndrome among them and result in absence from work and substandard services to their patients. Methodology: A cross-sectional study involving 19 government dental clinics in Perak was done over the period of 3 months. Those who met the criteria were selected to participate in this study. Malay version of the Self-Reported Nordic Musculoskeletal Discomfort Form was used to identify the prevalence of WRMSD, while the intensity of pain in the respective regions was evaluated using a 10-point scale according to ‘Pain as The 5ᵗʰ Vital Sign’ by MOH Malaysia and later on were analyzed using SPSS version 25. Descriptive statistics, including mean and SD and median and IQR, were used for numerical data. Categorical data were described by percentage. Pearson’s Chi-Square Test and Spearman’s Correlation were used to find the association between the prevalence of WRMSD and other socio-demographic data. Results: 159 dentists, 73 dental therapists, 26 dental lab technicians, 81 dental surgery assistants, and 23 dental attendants participated in this study. The mean age for the participants was 34.9±7.4 and their mean years of service was 9.97±7.5. Most of them were female (78.5%), Malay (71.3%), married (69.6%) and right-handed (90.1%). The highest prevalence of WRMSD was neck (58.0%), followed by shoulder (48.1%), upper back (42.0%), lower back (40.6%), hand/wrist (31.5%), feet (21.3%), knee (12.2%), thigh 7.7%) and lastly elbow (6.9%). Most of those who reported having neck pain scaled their pain experiences at 2 out of 10 (19.5%), while for those who suffered upper back discomfort, most of them scaled their pain experience at 6 out of 10 (17.8%). It was found that there was a significant relationship between age and pain at neck (p=0.007), elbow (p=0.027), lower back (p=0.032), thigh (p=0.039), knee (p=0.001) and feet (p=0.000) regions. Job position also had been found to be having a significant relationship with pain experienced at the lower back (p=0.018), thigh (p=0.011), knee, and feet (p=0.000). Conclusion: The prevalence of WRMSD among dental personnel in Perak was found to be high. Age and job position were found to be having a significant relationship with pain experienced in several regions. Intervention programs should be planned and conducted to prevent and reduce the occurrence of WRMSD, as all harmful or unergonomic practices should be avoided at all costs.Keywords: WRMSD, ergonomic, dentistry, dental
Procedia PDF Downloads 888589 Optimal Sliding Mode Controller for Knee Flexion during Walking
Authors: Gabriel Sitler, Yousef Sardahi, Asad Salem
Abstract:
This paper presents an optimal and robust sliding mode controller (SMC) to regulate the position of the knee joint angle for patients suffering from knee injuries. The controller imitates the role of active orthoses that produce the joint torques required to overcome gravity and loading forces and regain natural human movements. To this end, a mathematical model of the shank, the lower part of the leg, is derived first and then used for the control system design and computer simulations. The design of the controller is carried out in optimal and multi-objective settings. Four objectives are considered: minimization of the control effort and tracking error; and maximization of the control signal smoothness and closed-loop system’s speed of response. Optimal solutions in terms of the Pareto set and its image, the Pareto front, are obtained. The results show that there are trade-offs among the design objectives and many optimal solutions from which the decision-maker can choose to implement. Also, computer simulations conducted at different points from the Pareto set and assuming knee squat movement demonstrate competing relationships among the design goals. In addition, the proposed control algorithm shows robustness in tracking a standard gait signal when accounting for uncertainty in the shank’s parameters.Keywords: optimal control, multi-objective optimization, sliding mode control, wearable knee exoskeletons
Procedia PDF Downloads 828588 The Effect of Blood Flow Restriction on the Knee Rehabilitation
Authors: O. Casasayas, M. Vigo, R. Navarro, P. Ragazzi, P. Alvarez, A. Perez-Bellmunt
Abstract:
Introduction: The blood flow restriction training (BFR) is a method of muscle training that allows increasing the stress of muscle tissue to enhance the muscle cross-section and strength. This type of training has clear benefits in the rehabilitation field since it can improve muscle strength using low mechanical loads. The aim of this study is to know in which knee pathologies BFR has been used, what methodology was used and what were the obtained results. Study design: We performed a systematic literature search using strategies for the concepts of “blood flow restriction OR blood flow restriction training AND knee” in Medline. Articles were screened by authors and included if they used the blood flow restriction training in pathology of the knee. Results: The pathology more frequently treated by BFR was knee osteoarthritis and the variables most analyzed were strength and pain. The vascular occlusion used was 80% in the major part of studies. The groups of BFR obtained an increase of strength with less pain but not always the results are statistically significant. The evidence levels are poor in the high number of studies because in some cases there is not a control group or the evaluators were not blinded. Conclusion: The use of BFR is useful to improve muscle strength in knee pathology since it does not increase the pain, but more studies are needed to see (comprehend) if this type of treatment obtains better results than a conventional therapy. No studies have been found that compare the different occlusion effects in both the strength improvement and the pain reduction. Neither studies that analyse the effects of BFR on the muscle contractile parameters have been found.Keywords: blood flow restriction training, knee, arthroscopy knee, physical therapy
Procedia PDF Downloads 1688587 Comparison of the Proprioception Sense and Standing Balance in Patients with Osteoarthritis Before and After Total Knee Arthroplasty Surgery
Authors: S. Daneshi, G. Shahcheraghi, F. Ghaffarinejad
Abstract:
Back ground: Osteoarthritis (OA) is the most common form of arthritis, affecting millions of people around the world during the aging process. Knee joint proprioception sense decrease with OA and Total Knee Arthroplasty (TKA) surgery may affect them. We investigated two parameters of proprioception sense (the joint position sense and kinesthesia) and standing balance in affected limbs before and after TKA, in patient with Knee OA. Methods and Materials: In this Analytic study, 10 patients who were candidate for TKA during two months in Dena Hospital of Shiraz, selected for further analysis. All of cases were female in range of 55-70 years old. Participants assessed before and two weeks after TKA using three instruments: electrogoniometer and continuous passive motion (CPM) to assess Knee joint position sense and kinesthesia in 20 and 45 degrees; and chronometer to assess duration of standing balance on affected leg with open and closed eyes. Results: To examine differences between before and after of TKA scorings Willcoxon Signed Rank and Mann-Whitney was performed which indicated no significant differences between knee joint position sense and kinesthesia in 20 and 45 degrees (P>0.05) and no significant differences between Standing Balance in a patient with knee OA before and after TKA (P>0.05). Conclusion: The study indicates that, OA can affect proprioception sense and standing balance but TKA doesn’t have any effect on these parameters. Intra articular structures such as cruciate ligaments and mines are responsible for proprioception sense in normal knee joint. Since in severe knee OA the number of mechanoreceptors in these intra articular structures decrease and their function reduce more than normal knee joint, so the anterior cruciate ligaments (ACL) become defected, thus after TKA surgery which this ligament is removed no significant change was found in proprioception sense. As a result of involving proprioception sense, muscles strength and the function of vestibular system in balance, standing balance did not show significant difference before and after TKA.Keywords: knee joint, proprioception sense, standing balance, rehabilitation sciences
Procedia PDF Downloads 3808586 Socio-Demographic and Clinical Characteristics and Use of Herbal Medicine among Patients Seeking Consultation for Knee Osteoarthritis at Secondary Healthcare Facilities in Oman
Authors: Thuraya Ahmed Al Shidhani, Yahya Al Farsi, Alya Al Husni, Samir Al Adawi
Abstract:
Background: Knee osteoarthritis (knee OA) represents a major public health burden worldwide, particularly among older adults. However, little has been documented from Arabian Gulf countries, which have left an information gap. Objective: This study describes the socio-demographic, clinical risk factors, and use of herbal medicine among men and women seeking consultation for knee OA at two secondary healthcare facilities in Muscat, Oman. Methods: A cross-sectional study was conducted among 213 Omani adults with knee OA attending a referral polyclinic in Muscat, Oman, over 12 months from January to December. Socio-demographic data were collected from the participants who are seeking consultation for knee OA. Results: Among the 213 study participants, 171 were females and 42 males. The females were comparatively older than the males, had lower education and lower-income, and more overweight. The majority of the participants were normal weight or underweight. About one-third of participants reported OA in other joints as well. Most participants recalled that they had knee OA for less than a year. About 12% reported a history of trauma. The majority (63%) concurrently had other chronic illnesses, and 33% reported having at least one complication. About 22% were using herbal medicines. About 77% are using herbal local applications in form of powder and creams. Conclusion: This study, to our knowledge, is the first to explore socio-demographic characteristics, clinical risk factors and use of herbal medicine among sufferers of knee OA in Oman. Knee OA tended to occur among our participants at younger ages than reported elsewhere, while obesity appeared orthogonal to the severity of knee OA. Women were more affected than men. About one quarter of Omani patients are using herbal medicine. More studies are needed to understand the causal factors and development of knee OA in Oman. Targeted health education and rehabilitation programs are needed, particularly among Omani women, to improve their physical quality of life.Keywords: knee joint, osteoarthritis, herbal medicine, Oman
Procedia PDF Downloads 1238585 Energy Efficient Autonomous Lower Limb Exoskeleton for Human Motion Enhancement
Authors: Nazim Mir-Nasiri, Hudyjaya Siswoyo Jo
Abstract:
The paper describes conceptual design, control strategies, and partial simulation for a new fully autonomous lower limb wearable exoskeleton system for human motion enhancement that can support its weight and increase strength and endurance. Various problems still remain to be solved where the most important is the creation of a power and cost efficient system that will allow an exoskeleton to operate for extended period without batteries being frequently recharged. The designed exoskeleton is enabling to decouple the weight/mass carrying function of the system from the forward motion function which reduces the power and size of propulsion motors and thus the overall weight, cost of the system. The decoupling takes place by blocking the motion at knee joint by placing passive air cylinder across the joint. The cylinder is actuated when the knee angle has reached the minimum allowed value to bend. The value of the minimum bending angle depends on usual walk style of the subject. The mechanism of the exoskeleton features a seat to rest the subject’s body weight at the moment of blocking the knee joint motion. The mechanical structure of each leg has six degrees of freedom: four at the hip, one at the knee, and one at the ankle. Exoskeleton legs are attached to subject legs by using flexible cuffs. The operation of all actuators depends on the amount of pressure felt by the feet pressure sensors and knee angle sensor. The sensor readings depend on actual posture of the subject and can be classified in three distinct cases: subject stands on one leg, subject stands still on both legs and subject stands on both legs but transit its weight from one leg to other. This exoskeleton is power efficient because electrical motors are smaller in size and did not participate in supporting the weight like in all other existing exoskeleton designs.Keywords: energy efficient system, exoskeleton, motion enhancement, robotics
Procedia PDF Downloads 3698584 The Effect of Low Power Laser on CK and Some of Markers Delayed Onset Muscle Soreness (DOMS)
Authors: Bahareh Yazdanparast Chaharmahali
Abstract:
The study showed effect of low power laser therapy on knee range of motion (flexion and extension), resting angle of knee joint, knee circumference and rating of delayed onset muscle soreness induced pain, 24 and 48 hours after eccentric training of knee flexor muscle (hamstring muscle). We investigate the effects of pulsed ultrasound on swelling, relaxed, flexion and extension knee angle and pain. 20 volunteers among girl students of college voluntary participated in this research. After eccentric training, subjects were randomly divided into two groups, control and laser therapy. In day 1 and in order to induce delayed onset muscle soreness, subjects eccentrically trained their knee flexor muscles. In day 2, subjects were randomly divided into two groups: control and low power laser therapy. 24 and 48 hours after eccentric training. Variables (knee flexion and extension, srang of motion, resting knee joint angle and knee circumferences) were measured and analyzed. Data are reported as means ± standard error (SE) and repeated measured was used to assess differences within groups. Methods of treatment (low power laser therapy) have significant effects on delayed onset muscle soreness markers. 24 and 48 hours after training a significant difference was observed between mean pains of 2 groups. This difference was significant between low power laser therapy and C groups. The Bonferroni post hock is significant. Low power laser therapy trophy as used in this study did significantly diminish the effects of delayed – onset muscle soreness on swelling, relaxed – knee extension and flexion angle.Keywords: creatine kinase, DOMS, eccentric training, low power laser
Procedia PDF Downloads 2468583 The Influence of Using Soft Knee Pads on Static and Dynamic Balance among Male Athletes and Non-Athletes
Authors: Yaser Kazemzadeh, Keyvan Molanoruzy, Mojtaba Izady
Abstract:
The balance is the key component of motor skills to maintain postural control and the execution of complex skills. The present study was designed to evaluate the impact of soft knee pads on static and dynamic balance of male athletes. For this aim, thirty young athletes in different sport fields with 3 years professional sport training background and thirty healthy young men nonathletic (age: 24.5 ± 2.9, 24.3 ± 2.4, weight: 77.2 ± 4.3 and 80/9 ± 6/3 and height: 175 ± 2/84, 172 ± 5/44 respectively) as subjects selected. Then, subjects in two manner (without knee and with soft knee pads made of neoprene) execute standard error test (BESS) to assess static balance and star test to assess dynamic balance. For analyze of data, t-tests and one-way ANOVA were significant 05/0 ≥ α statistical analysis. The results showed that the use of soft knee significantly reduced error rate in static balance test (p ≥ 0/05). Also, use a soft knee pads decreased score of athlete group and increased score of nonathletic group in star test (p ≥ 0/05). These findings, indicates that use of knees affects static and dynamic balance in athletes and nonathletic in different manner and may increased athletic performance in sports that rely on static balance and decreased performance in sports that rely on dynamic balance.Keywords: static balance, dynamic balance, soft knee, athletic men, non athletic men
Procedia PDF Downloads 2908582 Comparative Study Between Continuous Versus Pulsed Ultrasound in Knee Osteoarthritis
Authors: Karim Mohamed Fawzy Ghuiba, Alaa Aldeen Abd Al Hakeem Balbaa, Shams Elbaz
Abstract:
Objectives: To compare between the effects continuous and pulsed ultrasound on pain and function in patient with knee osteoarthritis. Design: Randomized-Single blinded Study. Participants: 6 patients with knee osteoarthritis with mean age 53.66±3.61years, Altman Grade II or III. Interventions: Subjects were randomly assigned into two groups; Group A received continuous ultrasound and Group B received pulsed ultrasound. Outcome measures: Effects of pulsed and continuous ultrasound were evaluated by pain threshold assessed by visual analogue scale (VAS) scores and function assessed by the Western Ontario and McMaster Universities osteoarthritis index (WOMAC) scores. Results: There was no significant decrease in VAS and WOMAC scores in patients treated with pulsed or continuous ultrasound; and there were no significant differences between both groups. Conclusion: there is no difference between the effects of pulsed and continuous ultrasound in pain relief or functional outcome in patients with knee osteoarthritis.Keywords: knee osteoarthritis, pulsed ultrasound, ultrasound therapy, continuous ultrasound
Procedia PDF Downloads 2858581 Effect of Submaximal Eccentric versus Maximal Isometric Contraction on Delayed Onset Muscle Soreness
Authors: Mohamed M. Ragab, Neveen A. Abdel Raoof, Reham H. Diab
Abstract:
Background: Delayed onset muscle soreness (DOMS) is the most common symptom when ordinary individuals and athletes are exposed to unaccustomed physical activity, especially eccentric contraction which impairs athletic performance, ordinary people work ability and physical functioning. A multitude of methods have been investigated to reduce DOMS. One of the valuable method to control DOMS is repeated bout effect (RBE) as a prophylactic method. Purpose: To compare the repeated bout effect of submaximal eccentric contraction versus maximal isometric contraction on induced DOMS. Methods: Sixty normal male volunteers were assigned randomly into three groups of equal number: Group (A) “first study group”: 20 subjects received submaximal eccentric contraction on non-dominant elbow flexors as prophylactic exercise. Group (B) “second study group”: 20 subjects received maximal isometric contraction on non-dominant elbow flexors as prophylactic exercise. Group (C) “control group”: 20 subjects did not receive any prophylactic exercise. Maximal isometric contraction peak torque of elbow flexors and patient related elbow evaluation (PREE) scale were measured for each subject 3 times before, immediately after and 48 hours after induction of DOMS. Results: Post-hoc test for maximal isometric peak torque and PREE scale immediately and 48 hours after induction of DOMS revealed that group (A) and group (B) resulted in significant decrease in maximal isometric strength loss and elbow pain and disability rather than control group (C), but submaximal eccentric group (A) was more effective than maximal isometric group (B) as it showed more rapid recovery of functional strength and less degrees of elbow pain and disability. Conclusion: Both submaximal eccentric contraction and maximal isometric contraction were effective in prevention of DOMS but submaximal eccentric contraction had the greatest protective effect.Keywords: delayed onset muscle soreness, maximal isometric peak torque, patient related elbow evaluation scale, repeated bout effect
Procedia PDF Downloads 3658580 The Effect of Tai Chi Exercises on Postural Stability and Control in Older Patients with Knee Osteoarthritis
Authors: Elham Ghandali, Saeed Talebian Moghadam, Mohammad Reza Hadian, Gholamreza Olyaei, Shohreh Jalaie, Elaheh Sajjadi
Abstract:
Purpose: A few studies have examined the effect of Tai Chi on balance in elderly patients with knee osteoarthritis (OA). The aim of this study was to determine the balance measures in elderly patients with knee OA after Tai Chi exercises. For this purpose, 14 females and 6 males with knee OA were chosen. The area and mean velocity of the center of pressure movements (CoP) were measured by force plate in standing positions (on foam and rigid surfaces). The measurements of area and mean velocity of CoP were performed before and after 60 min of Tai Chi sessions (twice a week for 8 weeks). Results: The results showed that the area of CoP in a standing position on a rigid surface was significantly decreased (P < 0.01) after Tai Chi exercises. Furthermore, the mean velocity of CoP was significantly decreased after Tai Chi exercises on both rigid and foam surfaces (P < 0.001). Our study also indicated that changes in surfaces (rigid and foam) would cause significant differences regarding the area of CoP in standing positions. How- ever, similar findings were not found regarding the mean velocity of CoP. Considering the effects of Tai Chi on the mean velocity of CoP, it might be concluded that motor control and Postural stability improvements have occurred. Conclusions: Therefore, based on these results, Tai Chi exercises could be recommended for elderly patients with knee OA as part of their rehabilitation and physical therapy protocols.Keywords: Tai Chi, balance, knee osteoarthritis, elderly patients, different surfaces
Procedia PDF Downloads 948579 Comparison of Isokinetic Powers (Flexion and Knee Extension) of Basketball and Football Players (Age 17–20)
Authors: Ugur Senturk, Ibrahım Erdemır, Faruk Guven, Cuma Ece
Abstract:
The objective of this study is to compare flexion and extension movements in knee-joint group by measuring isokinetic knee power of amateur basketball and football players. For this purpose, total 21 players were included, which consist of football players (n=12) and basketball players (n=9), within the age range of 17–20. After receiving the age, length, body weight, vertical jump, and BMI measurements of all subjects, the measurement of lower extremity knee-joint movement (Flexion-Extension) was made with isokinetic dynamometer (isomed 2000) at 60 o/sec. and 240 o/sec. angular velocity. After arrangement and grouping of collected information forms and knee flexion and extension parameters, all data were analyzed with SPSS for Windows. Descriptive analyses of the parameters were made. Non-parametric t test and Mann-Whitney U test were used to compare the parameters of football players and basketball players and to find the inter-group differences. The comparisons and relations in the range p<0.05 and p<0.01 between the groups were surveyed. As a conclusion, no statistical differences were found between isokinetic knee flexion and extension parameters of football and basketball players. However, it was found that the football players were older than the basketball players. In addition to this, the average values of the basketball players in the highest torque and the highest torque average curve were found higher than football players in comparisons of left knee extension. However, it was found that fat levels of the basketball players were found to be higher than the football players.Keywords: isokinetic contraction, isokinetic dynamometer, peak torque, flexion, extension, football, basketball
Procedia PDF Downloads 5308578 Ultrasonography of Low Extremities Veins Before and After Replacement of Knee Joint by Endoprosthesis
Authors: A. V. Alabut, V. D. Sikilinda, N. J. Nelasov, O. L. Eroshenko, M. N. Morgunov, I. V. Koroleva
Abstract:
We have analyzed the results of treatment of 204 patients with knee prosthetic arthroplasty. For the purpose of active delineation of vascular pathology triplex sonography of arterial and venous vessels of low extremities was performed in all cases in the preoperative period. When it was necessary, reconstructive vascular surgery was implemented to improve peripheral circulation and reduce the hazard of thrombosis after knee replacement. The combination of specific and nonspecific methods of thromboprophylaxis was used in perioperative period. On 7-10 day and 2.5-3 month after prosthetic arthroplasty, all patients iteratively underwent triple sonography. In case of detection of floating thrombus, urgent venous ligation was performed. Active diagnostics of venous thrombosis gave the opportunity to avoid fatal pulmonary embolism.Keywords: knee replacement, venous thrombosis, pulmonary embolism, vascular surgery
Procedia PDF Downloads 3698577 Clinical and Structural Differences in Knee Osteoarthritis with/without Synovial Hypertrophy
Authors: Gi-Young Park, Dong Rak Kwon, Sung Cheol Cho
Abstract:
Objective: The synovium is known to be involved in many pathological characteristic processes. Also, synovitis is common in advanced osteoarthritis. We aimed to evaluate the clinical, radiographic, and ultrasound findings in patients with knee osteoarthritis and to compare the clinical and imaging findings between knee osteoarthritis with and without synovial hypertrophy confirmed by ultrasound. Methods: One hundred knees (54 left, 46 right) in 95 patients (64 women, 31 men; mean age, 65.9 years; range, 43-85 years) with knee osteoarthritis were recruited. The Visual Analogue Scale (VAS) was used to assess the intensity of knee pain. The severity of knee osteoarthritis was classified according to Kellgren and Lawrence's (K-L) grade on a radiograph. Ultrasound examination was performed by a physiatrist who had 24 years of experience in musculoskeletal ultrasound. Ultrasound findings, including the thickness of joint effusion in the suprapatellar pouch, synovial hypertrophy, infrapatellar tendinosis, meniscal tear or extrusion, and Baker cyst, were measured and detected. The thickness of knee joint effusion was measured at the maximal anterior-posterior diameter of fluid collection in the suprapatellar pouch. Synovial hypertrophy was identified as the soft tissue of variable echogenicity, which is poorly compressible and nondisplaceable by compression of an ultrasound transducer. The knees were divided into two groups according to the presence of synovial hypertrophy. The differences in clinical and imaging findings between the two groups were evaluated by independent t-test and chi-square test. Results: Synovial hypertrophy was detected in 48 knees of 100 knees on ultrasound. There were no significant differences in demographic parameters and VAS score except in sex between the two groups (P<0.05). Medial meniscal extrusion and tear were significantly more frequent in knees with synovial hypertrophy than those in knees without synovial hypertrophy. K-L grade and joint effusion thickness were greater in patients with synovial hypertrophy than those in patients without synovial hypertrophy (P<0.05). Conclusion: Synovial hypertrophy in knee osteoarthritis was associated with greater suprapatellar joint effusion and higher K-L grade and maybe a characteristic ultrasound feature of late knee osteoarthritis. These results suggest that synovial hypertrophy on ultrasound can be regarded as a predictor of rapid progression in patients with knee osteoarthritis.Keywords: knee osteoarthritis, synovial hypertrophy, ultrasound, K-L grade
Procedia PDF Downloads 758576 Successful Rehabilitation of Recalcitrant Knee Pain Due to Anterior Cruciate Ligament Injury Masked by Extensive Skin Graft: A Case Report
Authors: Geum Yeon Sim, Tyler Pigott, Julio Vasquez
Abstract:
A 38-year-old obese female with no apparent past medical history presented with left knee pain. Six months ago, she sustained a left knee dislocation in a motor vehicle accident that was managed with a skin graft over the left lower extremity without any reconstructive surgery. She developed persistent pain and stiffness in her left knee that worsened with walking and stair climbing. Examination revealed healed extensive skin graft over the left lower extremity, including the left knee. Palpation showed moderate tenderness along the superior border of the patella, exquisite tenderness over MCL, and mild tenderness on the tibial tuberosity. There was normal sensation, reflexes, and strength in her lower extremities. There was limited active and passive range of motion of her left knee during flexion. There was instability noted upon the valgus stress test of the left knee. Left knee magnetic resonance imaging showed high-grade (grade 2-3) injury of the proximal superficial fibers of the MCL and diffuse thickening and signal abnormality of the cruciate ligaments, as well as edema-like subchondral marrow signal change in the anterolateral aspect of the lateral femoral condyle weight-bearing surface. There was also notable extensive scarring and edema of the skin, subcutaneous soft tissues, and musculature surrounding the knee. The patient was managed with left knee immobilization for five months, which was complicated by limited knee flexion. Physical therapy consisting of quadriceps, hamstrings, gastrocnemius stretching and strengthening, range of motion exercises, scar/soft tissue mobilization, and gait training was given with marked improvement in pain and range of motion. The patient experienced a further reduction in pain as well as an improvement in function with home exercises consisting of continued strengthening and stretching.Keywords: ligamentous injury, trauma, rehabilitation, knee pain
Procedia PDF Downloads 1088575 Seismic Behaviour of RC Knee Joints in Closing and Opening Actions
Authors: S. Mogili, J. S. Kuang, N. Zhang
Abstract:
Knee joints, the beam column connections found at the roof level of a moment resisting frame buildings, are inherently different from conventional interior and exterior beam column connections in the way that forces from adjoining members are transferred into joint and then resisted by the joint. A knee connection has two distinct load resisting mechanisms, each for closing and opening actions acting simultaneously under reversed cyclic loading. In spite of many distinct differences in the behaviour of shear resistance in knee joints, there are no special design provisions in the major design codes available across the world due to lack of in-depth research on the knee connections. To understand the relative importance of opening and closing actions in design, it is imperative to study knee joints under varying shear stresses, especially at higher opening-to-closing shear stress ratios. Three knee joint specimens, under different input shear stresses, were designed to produce a varying ratio of input opening to closing shear stresses. The design was carried out in such a way that the ratio of flexural strength of beams with consideration of axial forces in opening to closing actions are maintained at 0.5, 0.7, and 1.0, thereby resulting in the required variation of opening to closing joint shear stress ratios among the specimens. The behaviour of these specimens was then carefully studied in terms of closing and opening capacities, hysteretic behaviour, and envelope curves to understand the differences in joint performance based on which an attempt to suggest design guidelines for knee joints is made emphasizing the relative importance of opening and closing actions. Specimens with relatively higher opening stresses were observed to be more vulnerable under the action of seismic loading.Keywords: Knee-joints, large-scale testing, opening and closing shear stresses, seismic performance
Procedia PDF Downloads 2218574 The Osteocutaneous Distal Tibia Turn-over Fillet Flap: A Novel Spare-parts Orthoplastic Surgery Option for Functional Below-knee Amputation
Authors: Harry Burton, Alexios Dimitrios Iliadis, Neil Jones, Aaron Saini, Nicola Bystrzonowski, Alexandros Vris, Georgios Pafitanis
Abstract:
This article portrays the authors’ experience with a complex lower limb bone and soft tissue defect, following chronic osteomyelitis and pathological fracture, which was managed by the multidisciplinary orthoplastic team. The decision for functional amputation versus limb salvage was deemed necessary, enhanced by the principles of “spares parts” in reconstructive microsurgery. This case describes a successful use of the osteocutaneous distal tibia turn-over fillet flap that allowed ‘lowering the level of the amputation’ from a through knee to the conventional level of a below-knee amputation to preserve the knee joint function. This case demonstrates the value of ‘spare-parts’ surgery principles and how these concepts refine complex orthoplastic approaches when limb salvage is not possible to enhance function. The osteocutaneous distal tibia turn-over fillet flap is a robust technique for modified BKA reconstructions that provides sufficient bone length to achieve a tough, sensate stump and functional knee joint.Keywords: osteocutaneous flap, fillet flap, spare-parts surgery, Below knee amputation
Procedia PDF Downloads 1668573 Foot Recognition Using Deep Learning for Knee Rehabilitation
Authors: Rakkrit Duangsoithong, Jermphiphut Jaruenpunyasak, Alba Garcia
Abstract:
The use of foot recognition can be applied in many medical fields such as the gait pattern analysis and the knee exercises of patients in rehabilitation. Generally, a camera-based foot recognition system is intended to capture a patient image in a controlled room and background to recognize the foot in the limited views. However, this system can be inconvenient to monitor the knee exercises at home. In order to overcome these problems, this paper proposes to use the deep learning method using Convolutional Neural Networks (CNNs) for foot recognition. The results are compared with the traditional classification method using LBP and HOG features with kNN and SVM classifiers. According to the results, deep learning method provides better accuracy but with higher complexity to recognize the foot images from online databases than the traditional classification method.Keywords: foot recognition, deep learning, knee rehabilitation, convolutional neural network
Procedia PDF Downloads 1618572 A Review of Kinematics and Joint Load Forces in Total Knee Replacements Influencing Surgical Outcomes
Authors: Samira K. Al-Nasser, Siamak Noroozi, Roya Haratian, Adrian Harvey
Abstract:
A total knee replacement (TKR) is a surgical procedure necessary when there is severe pain and/or loss of function in the knee. Surgeons balance the load in the knee and the surrounding soft tissue by feeling the tension at different ranges of motion. This method can be unreliable and lead to early failure of the joint. The ideal kinematics and load distribution have been debated significantly based on previous biomechanical studies surrounding both TKRs and normal knees. Intraoperative sensors like VERASENSE and eLibra have provided a method for the quantification of the load indicating a balanced knee. A review of the literature written about intraoperative sensors and tension/stability of the knee was done. Studies currently debate the quantification of the load in medial and lateral compartments specifically. However, most research reported that following a TKR the medial compartment was loaded more heavily than the lateral compartment. In several cases, these results were shown to increase the success of the surgery because they mimic the normal kinematics of the knee. In conclusion, most research agrees that an intercompartmental load differential of between 10 and 20 pounds, where the medial load was higher than the lateral, and an absolute load of less than 70 pounds was ideal. However, further intraoperative sensor development could help improve the accuracy and understanding of the load distribution on the surgical outcomes in a TKR. A reduction in early revision surgeries for TKRs would provide an improved quality of life for patients and reduce the economic burden placed on both the National Health Service (NHS) and the patient.Keywords: intraoperative sensors, joint load forces, kinematics, load balancing, and total knee replacement
Procedia PDF Downloads 1368571 Nanoindentation Behaviour and Microstructural Evolution of Annealed Single-Crystal Silicon
Authors: Woei-Shyan Lee, Shuo-Ling Chang
Abstract:
The nanoindentation behaviour and phase transformation of annealed single-crystal silicon wafers are examined. The silicon specimens are annealed at temperatures of 250, 350 and 450ºC, respectively, for 15 minutes and are then indented to maximum loads of 30, 50 and 70 mN. The phase changes induced in the indented specimens are observed using transmission electron microscopy (TEM) and micro-Raman scattering spectroscopy (RSS). For all annealing temperatures, an elbow feature is observed in the unloading curve following indentation to a maximum load of 30 mN. Under higher loads of 50 mN and 70 mN, respectively, the elbow feature is replaced by a pop-out event. The elbow feature reveals a complete amorphous phase transformation within the indented zone, whereas the pop-out event indicates the formation of Si XII and Si III phases. The experimental results show that the formation of these crystalline silicon phases increases with an increasing annealing temperature and indentation load. The hardness and Young’s modulus both decrease as the annealing temperature and indentation load are increased.Keywords: nanoindentation, silicon, phase transformation, amorphous, annealing
Procedia PDF Downloads 3738570 Correlation between Dynamic Knee Valgus with Isometric Hip Abductors Strength during Single-Leg Landing
Authors: Ahmed Fawzy, Khaled Ayad, Gh. M. Koura, W. Reda
Abstract:
The knee joint complex is one of the most commonly injured areas of the body in athletes. Excessive frontal plane knee excursion is considered a risk factor for multiple knee pathologies such as anterior cruciate ligament and patellofemoral joint injuries, however, little is known about the biomechanical factors that contribute to this loading pattern. Objectives: The purpose of this study was to investigate if there is a relationship between hip abductors isometric strength and the value of FPPA during single leg landing tasks in normal male subjects. Methods: One hundred (male) subjects free from lower extremity injuries for at least six months ago participated in this study. Their mean age was (23.25 ± 2.88) years, mean weight was (74.76 ± 13.54) (Kg), mean height was (174.23 ± 6.56) (Cm). The knee frontal plane projection angle was measured by digital video camera using single leg landing task. Hip abductors isometric strength were assessed by portable hand-held dynamometer. Muscle strength had been normalized to the body weight to obtain more accurate measurements. Results: The results demonstrated that there was no significant relationship between hip abductors isometric strength and the value of FPPA during single leg landing tasks in normal male subjects. Conclusion: It can be concluded that there is no relationship between hip abductors isometric strength and the value of FPPA during functional activities in normal male subjects.Keywords: 2-dimensional motion analysis, hip strength, kinematics, knee injuries
Procedia PDF Downloads 2488569 Effects of the Amount of Static Stretching on the Knee Isokinetic Muscle Strength
Authors: Chungyu Chen, Hui-Ju Chang, Pei-Shan Guo, Huei-Ling Jhan, Yi-Ping Lin
Abstract:
The purpose of this study was to investigate the effect of the amount of acutely static stretching on muscular strength and power. There were 15 males, and 7 females recruited voluntarily as the participants in the study. The mean age, body height, and weight of participants were 23.4 ± 2.8 years old, 171.0 ± 7.2 cm, and 65.7 ± 8.7 kg, respectively. Participants were repeated to stretch hamstring muscles 2 or 6 30-s bouts randomly on a separate day spaced 5-7 days apart in a passive, static, sit-and-reach stretching exercise. Before and after acutely static stretching, the Biodex System 4 Pro was used to acquire the peak torque, power, total work, and range of motion for right knee under the loading of 180 deg/s. The 2 (test-retest) × 2 (number of stretches) repeated measures two-way analysis of variance were used to compare the parameters of muscular strength/power (α = .05). The results showed that the peak torque, power, and total work increased significantly after acutely passive static stretching (ps < .05) in flexor and extensor of knee. But there were no significant differences found between the 2 and 6 30-s bouts hamstring muscles stretching (ps > .05). It indicated that the performance of muscular strength and power in knee flexion and extension do not inhibit following the increase of amount of stretching.Keywords: knee, power, flexibility, strength
Procedia PDF Downloads 2798568 Posterior Thigh Compartment Syndrome Associated with Hamstring Avulsion and Antiplatelet Therapy
Authors: Andrea Gatti, Federica Coppotelli, Ma Primavera, Laura Palmieri, Umberto Tarantino
Abstract:
Aim of study: Scientific literature is scarce of studies and reviews valuing the pros and cons of the paratricipital approach for the treatment of humeral shaft fractures; the lateral paratricipital approach is a valid alternative to the classical posterior approach to the humeral shaft as it preserves both the triceps muscle and the elbow extensor mechanisms; based on our experience, this retrospective analysis aims at analyzing outcome, risks and benefits of the lateral paratricipital approach for humeral shaft fractures. Methods: Our study includes 14 patients treated between 2018 and 2019 for unilateral humeral shaft fractures: 13 with a B1 or B2 and a patient with a C fracture type (according to the AO/ATO Classification); 6 of our patients identified as male while 8 as female; age average was 57.8 years old (range 21-73 years old). A lateral paratricipital approach was performed on all 14 patients, sparing the triceps muscle by avoiding the olecranon osteotomy and by assessing the integrity and the preservation of the radial nerve; the humeral shaft fracture osteosynthesis was performed by means of plates and screws. After surgery all patients have started elbow functional rehabilitation with acceptable pain management. Post-operative follow-up has been carried out by assessing radiographs, MEPS (Mayo Elbow Performance Score) and DASH (Disability of Arm Shoulder and Hand) functional assessment and ROM of the affected joint. Results: All 14 patients had an optimal post-operative follow-up with an adequate osteosynthesis and functional rehabilitations by entirely preserving the operated elbow joint; the mean elbow ROM was 0-118.6 degree (range of 0-130) while the average MEPS score was 86 (range75-100) and 79.9 for the DASH (range 21.7-86.1). Just 2 patients suffered of temporary radial nerve apraxia, healed in the subsequent follow-ups. CONCLUSION: The lateral paratricipital approach preserve both the integrity of the triceps muscle and the elbow biomechanism but we do strongly recommend additional studies to be carried out to highlight differences between it and the classical posterior approach in treating humeral shaft fractures.Keywords: paratricepital approach, humerus shaft fracture, posterior approach humeral shaft, paratricipital postero-lateral approach
Procedia PDF Downloads 1298567 Design and Evaluation of Corrective Orthosis Knee for Hyperextension
Authors: Valentina Narvaez Gaitan, Paula K. Rodriguez Ramirez, Derian D. Espinosa
Abstract:
Corrective orthosis has great importance in orthopedic treatments providing assistance in improving mobility and stability in order to improve the quality of life for a different patient. The corrective orthosis studied in this article can correct deformities, reduce pain, and improve the ability to perform daily activities. This work describes the design and evaluation of a corrective orthosis for knee hyperextension. This orthosis is capable of generating a progressive and variable alignment of the joint, limiting the range of motion according to medical criteria. The main objective was to design a corrective knee orthosis capable of correcting knee hyperextension progressively to return to its natural angle with greater economic affordability and adjustable size. The limiting mechanism is based on a goniometer to determine the desired angles. The orthosis was made of acrylic to reduce costs and maintenance; neoprene is also used to make comfortable contact; additionally, Velcro was used in order to adjust the orthosis for various sizes. Simulations of static and fatigue analysis of the mechanism were performed to verify its resistance and durability under normal conditions. A biomechanical gait study of gait was carried out on 10 healthy subjects without the orthosis and limiting their knee extension capacity in a normal gait cycle with the orthosis to observe the efficiency of the proposed system. In the results obtained, the knee angle curves show that the maximum extension angle was the established angle by the orthosis. Showing the efficiency of the proposed design for different leg sizes.Keywords: biomechanical study, corrective orthosis, efficiency, goniometer, knee hyperextension.
Procedia PDF Downloads 818566 Gait Analysis in Total Knee Arthroplasty
Authors: Neeraj Vij, Christian Leber, Kenneth Schmidt
Abstract:
Introduction: Total knee arthroplasty is a common procedure. It is well known that the biomechanics of the knee do not fully return to their normal state. Motion analysis has been used to study the biomechanics of the knee after total knee arthroplasty. The purpose of this scoping review is to summarize the current use of gait analysis in total knee arthroplasty and to identify the preoperative motion analysis parameters for which a systematic review aimed at determining the reliability and validity may be warranted. Materials and Methods: This IRB-exempt scoping review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) checklist strictly. Five search engines were searched for a total of 279 articles. Articles underwent a title and abstract screening process followed by full-text screening. Included articles were placed in the following sections: the role of gait analysis as a research tool for operative decisions, other research applications for motion analysis in total knee arthroplasty, gait analysis as a tool in predicting radiologic outcomes, gait analysis as a tool in predicting clinical outcomes. Results: Eleven articles studied gait analysis as a research tool in studying operative decisions. Motion analysis is currently used to study surgical approaches, surgical techniques, and implant choice. Five articles studied other research applications for motion analysis in total knee arthroplasty. Other research applications for motion analysis currently include studying the role of the unicompartmental knee arthroplasty and novel physical therapy protocols aimed at optimizing post-operative care. Two articles studied motion analysis as a tool for predicting radiographic outcomes. Preoperative gait analysis has identified parameters than can predict postoperative tibial component migration. 15 articles studied motion analysis in conjunction with clinical scores. Conclusions: There is a broad range of applications within the research domain of total knee arthroplasty. The potential application is likely larger. However, the current literature is limited by vague definitions of ‘gait analysis’ or ‘motion analysis’ and a limited number of articles with preoperative and postoperative functional and clinical measures. Knee adduction moment, knee adduction impulse, total knee range of motion, varus angle, cadence, stride length, and velocity have the potential for integration into composite clinical scores. A systematic review aimed at determining the validity, reliability, sensitivities, and specificities of these variables is warranted.Keywords: motion analysis, joint replacement, patient-reported outcomes, knee surgery
Procedia PDF Downloads 948565 Development the Sensor Lock Knee Joint and Evaluation of Its Effect on Walking and Energy Consumption in Subjects With Quadriceps Weakness
Authors: Mokhtar Arazpour
Abstract:
Objectives: Recently a new kind of stance control knee joint has been developed called the 'sensor lock.' This study aimed to develop and evaluate 'sensor lock', which could potentially solve the problems of walking parameters and gait symmetry in subjects with quadriceps weakness. Methods: Nine subjects with quadriceps weakness were enrolled in this study. A custom-made knee ankle foot orthosis (KAFO) with the same set of components was constructed for each participant. Testing began after orthotic gait training was completed with each of the KAFOs and subjects demonstrated that they could safely walk with crutches. Subjects rested 30 minutes between each trial. The 10 meters walking test is used to assess walking speed in meters/second (m/s). The total time taken to ambulate 6 meters (m) is recorded to the nearest hundredth of a second. 6 m is then divided by the total time (in seconds) taken to ambulate and recorded in m/s. The 6 Minutes Walking Test was used to assess walking endurance in this study. Participants walked around the perimeter of a set circuit for a total of six minutes. To evaluate Physiological cost index (PCI), the subjects were asked to walk using each type of KAFOs along a pre-determined 40 m rectangular walkway at their comfortable self-selected speed. A stopwatch was used to calculate the speed of walking by measuring the time between starting and stopping time and the distance walked. Results: The use of a KAFO fitted with the “sensor lock” knee joint resulted in improvements to walking speed, distance walked and physiological cost index when compared with the knee joint in lock mode. Conclusions: This study demonstrated that the use of a KAFO with the “sensor lock” knee joint could provide significant benefits for subjects with a quadriceps weakness when compared to a KAFO with the knee joint in lock mode.Keywords: stance control knee joint, knee ankle foot orthosis, quadriceps weakness, walking, energy consumption
Procedia PDF Downloads 1258564 Medical Image Augmentation Using Spatial Transformations for Convolutional Neural Network
Authors: Trupti Chavan, Ramachandra Guda, Kameshwar Rao
Abstract:
The lack of data is a pain problem in medical image analysis using a convolutional neural network (CNN). This work uses various spatial transformation techniques to address the medical image augmentation issue for knee detection and localization using an enhanced single shot detector (SSD) network. The spatial transforms like a negative, histogram equalization, power law, sharpening, averaging, gaussian blurring, etc. help to generate more samples, serve as pre-processing methods, and highlight the features of interest. The experimentation is done on the OpenKnee dataset which is a collection of knee images from the openly available online sources. The CNN called enhanced single shot detector (SSD) is utilized for the detection and localization of the knee joint from a given X-ray image. It is an enhanced version of the famous SSD network and is modified in such a way that it will reduce the number of prediction boxes at the output side. It consists of a classification network (VGGNET) and an auxiliary detection network. The performance is measured in mean average precision (mAP), and 99.96% mAP is achieved using the proposed enhanced SSD with spatial transformations. It is also seen that the localization boundary is comparatively more refined and closer to the ground truth in spatial augmentation and gives better detection and localization of knee joints.Keywords: data augmentation, enhanced SSD, knee detection and localization, medical image analysis, openKnee, Spatial transformations
Procedia PDF Downloads 1548563 Effect of Different Knee-Joint Positions on Passive Stiffness of Medial Gastrocnemius Muscle and Aponeuroses during Passive Ankle Motion
Authors: Xiyao Shan, Pavlos Evangelidis, Adam Kositsky, Naoki Ikeda, Yasuo Kawakami
Abstract:
The human triceps surae (two bi-articular gastrocnemii and one mono-articular soleus) have aponeuroses in the posterior and anterior aspects of each muscle, where the anterior aponeuroses of the gastrocnemii adjoin the posterior aponeurosis of the soleus, possibly contributing to the intermuscular force transmission between gastrocnemii and soleus. Since the mechanical behavior of these aponeuroses at different knee- and ankle-joint positions remains unclear, the purpose of this study was to clarify this through observations of the localized changes in passive stiffness of the posterior aponeuroses, muscle belly and adjoining aponeuroses of the medial gastrocnemius (MG) induced by different knee and ankle angles. Eleven healthy young males (25 ± 2 yr, 176.7 ± 4.7 cm, 71.1 ± 11.1 kg) participated in this study. Each subject took either a prone position on an isokinetic dynamometer while the knee joint was fully extended (K180) or a kneeling position while the knee joint was 90° flexed (K90), in a randomized and counterbalanced order. The ankle joint was then passively moved through a 50° range of motion (ROM) by the dynamometer from 30° of plantar flexion (PF) to 20° of dorsiflexion (DF) at 2°/s and the ultrasound shear-wave velocity was measured to obtain shear moduli of the posterior aponeurosis, MG belly, and adjoining aponeuroses. The main findings were: 1) shear modulus in K180 was significantly higher (p < 0.05) than K90 for the posterior aponeurosis (across all ankle angles, 10.2 ± 5.7 kPa-59.4 ± 28.7 kPa vs. 5.4 ± 2.2 kPa-11.6 ± 4.1 kPa), MG belly (from PF10° to DF20°, 9.7 ± 2.2 kPa-53.6 ± 18.6 kPa vs. 8.0 ± 2.7 kPa-9.5 ± 3.7 kPa), and adjoining aponeuroses (across all ankle angles, 17.3 ± 7.8 kPa-80 ± 25.7 kPa vs. 12.2 ± 4.5 kPa-52.4 ± 23.0 kPa); 2) shear modulus of the posterior aponeuroses significantly increased (p < 0.05) from PF10° to PF20° in K180, while shear modulus of MG belly significantly increased (p < 0.05) from 0° to PF20° only in K180 and shear modulus of adjoining aponeuroses significantly increased (p < 0.05) across the whole ROM of ankle both in K180 and K90. These results suggest that different knee-joint positions can affect not only the bi-articular gastrocnemius but also influence the mechanical behavior of aponeuroses. In addition, compared to the gradual stiffening of the adjoining aponeuroses across the whole ROM of ankle, the posterior aponeurosis became slack in the plantar flexed positions and then was stiffened gradually as the knee was fully extended. This suggests distinct stiffening for the posterior and adjoining aponeuroses which is joint position-dependent.Keywords: aponeurosis, plantar flexion and dorsiflexion, shear modulus, shear wave elastography
Procedia PDF Downloads 1908562 A Failure Investigations of High-Temperature Hydrogen Attack at Plat Forming Unit Furnace Elbow
Authors: Altoumi Alndalusi
Abstract:
High-temperature hydrogen attack (HTHA) failure is the common phenomena at elevated temperature in hydrogen environment in oil and gas field. The failure occurred once after four years at the internal surface of Platforming elbow. Both visual and microscopic examinations revealed that the failure was initiated due to blistering forming followed by large cracking at the inner surface. Crack morphology showed that the crack depth was about 50% of material wall thickness and its behavior generally was intergranular. This study concluded that the main reason led to failure due to incorrect material selection comparing to the platforming conditions.Keywords: decarburization, failure, heat affected zone, morphology, partial pressure, plate form
Procedia PDF Downloads 156