11050 Optimal Bayesian Chart for Controlling Expected Number of Defects in Production Processes

Authors: V. Makis, L. Jafari

Abstract:

In this paper, we develop an optimal Bayesian chart to control the expected number of defects per inspection unit in production processes with long production runs. We formulate this control problem in the optimal stopping framework. The objective is to determine the optimal stopping rule minimizing the long-run expected average cost per unit time considering partial information obtained from the process sampling at regular epochs. We prove the optimality of the control limit policy, i.e., the process is stopped and the search for assignable causes is initiated when the posterior probability that the process is out of control exceeds a control limit. An algorithm in the semi-Markov decision process framework is developed to calculate the optimal control limit and the corresponding average cost. Numerical examples are presented to illustrate the developed optimal control chart and to compare it with the traditional u-chart.

Keywords: Bayesian u-chart, economic design, optimal stopping, semi-Markov decision process, statistical process control

Procedia PDF Downloads 556
11049 Sampled-Data Control for Fuel Cell Systems

Authors: H. Y. Jung, Ju H. Park, S. M. Lee

Abstract:

A sampled-data controller is presented for solid oxide fuel cell systems which is expressed by a sector bounded nonlinear model. The sector bounded nonlinear systems, which have a feedback connection with a linear dynamical system and nonlinearity satisfying certain sector type constraints. Also, the sampled-data control scheme is very useful since it is possible to handle digital controller and increasing research efforts have been devoted to sampled-data control systems with the development of modern high-speed computers. The proposed control law is obtained by solving a convex problem satisfying several linear matrix inequalities. Simulation results are given to show the effectiveness of the proposed design method.

Keywords: sampled-data control, fuel cell, linear matrix inequalities, nonlinear control

Procedia PDF Downloads 554
11048 Robust Control of Cyber-Physical System under Cyber Attacks Based on Invariant Tubes

Authors: Bruno Vilić Belina, Jadranko Matuško

Abstract:

The rapid development of cyber-physical systems significantly influences modern control systems introducing a whole new range of applications of control systems but also putting them under new challenges to ensure their resiliency to possible cyber attacks, either in the form of data integrity attacks or deception attacks. This paper presents a model predictive approach to the control of cyber-physical systems robust to cyber attacks. We assume that a cyber attack can be modelled as an additive disturbance that acts in the measuring channel. For such a system, we designed a tube-based predictive controller based. The performance of the designed controller has been verified in Matlab/Simulink environment.

Keywords: control systems, cyber attacks, resiliency, robustness, tube based model predictive control

Procedia PDF Downloads 51
11047 Application of Fractional Model Predictive Control to Thermal System

Authors: Aymen Rhouma, Khaled Hcheichi, Sami Hafsi

Abstract:

The article presents an application of Fractional Model Predictive Control (FMPC) to a fractional order thermal system using Controlled Auto Regressive Integrated Moving Average (CARIMA) model obtained by discretization of a continuous fractional differential equation. Moreover, the output deviation approach is exploited to design the K -step ahead output predictor, and the corresponding control law is obtained by solving a quadratic cost function. Experiment results onto a thermal system are presented to emphasize the performances and the effectiveness of the proposed predictive controller.

Keywords: fractional model predictive control, fractional order systems, thermal system, predictive control

Procedia PDF Downloads 398
11046 Implementing Digital Control System in Robotics

Authors: Safiullah Abdullahi

Abstract:

This paper describes the design of a digital control system which controls the speed and direction of a robot. The robot is expected to follow a black thick line with the highest possible speed and lowest error around the line. The control system of the robot will correct for the angle error that is made between the frame axis of the robot and the line. The cause for error is the difference in speed of the two driving wheels of the robot which are driven by two separate DC motors, whereas the speed difference in wheels is due to the un-modeled fraction that is available in the wheels with different magnitudes in each. The control scheme is that a number of photo sensors are mounted in the front of the robot and report their position in reference to the black line to the digital controller. The controller then, evaluates the position error and generates the needed duty cycle for the related wheel motor to drive it faster or slower.

Keywords: digital control, robot, controller, control system

Procedia PDF Downloads 536
11045 Case Report on Sepsis by Alpha-Hemolytic Streptococcus and Mannheimia haemolytica in Neonate Dogs

Authors: Maria L. G. Lourenco, Keylla H. N. P. Pereira, Viviane Y. Hibaru, Fabiana F. Souza, Joao C. P. Ferreira, Simone B. Chiacchio, Luiz H. A. Machado

Abstract:

Neonatal sepsis is a systemic response of acute infection by bacteria that may lead to high mortality in a litter. This study aims to report a case of sepsis by alpha-hemolytic Streptococcus and Mannheimia haemolytica in neonate dogs. A pregnant, mixed-breed bitch at approximately the 60th day of pregnancy was admitted to the Sao Paulo State University (UNESP) Veterinary Hospital, Botucatu, Sao Paulo, Brazil, and subjected to a c-section due to uterine atony and fetuses no heartbeats on the ultrasound examination. The mother presented leukopenia of 1.6 thousand leukocytes, and there was no other information regarding previous clinical history. Among the offspring, four were stillborn, and five were born alive. On clinical examination, neonates weighed between 312 and 384 grams. Reflexes were present, and the newborn's body temperature was between 89.9 ºF and 96.4 ºF. Neonates also presented clinical signs of neonatal infection: omphalitis, abdomen, and extremities with cyanotic color, hematuria, and diarrhea (meconium). Complementary tests revealed leukopenia. The presence of alpha hemolytic streptococcus and Mannheimia haemolytica was revealed in the bacterial culture. The bacteria were sensitive to cephalosporins and penicillin on the antibiogram. Treatment for sepsis was instituted with the drug ceftriaxone, at a dose of 50 mg per kilogram, administered intravenous (jugular vein). Subsequently administered subcutaneous, every 12 hours, for seven days. Heated fluid therapy was performed, with Ringer lactate, at a dose of 4 ml per 100 grams of weight, intravenous. Heating measures were instituted. Blood plasma was also administered, at a dose of 2 mL per 100 grams of weight, administered subcutaneous, as a source of passive immunity. A maternal milk substitute was instituted, and lactation was discontinued since the mother was unable to nurse due to the infection. The mother was neutered during the c-section and treated with ceftriaxone (50 mg/kg). After seven days, the newborns presented normal clinical signs and no alterations in the hemogram. Early diagnosis and intervention were essential for the survival of these patients.

Keywords: neonatal infection, puppies, bacteria, newborn

Procedia PDF Downloads 104
11044 An Integrated HCV Testing Model as a Method to Improve Identification and Linkage to Care in a Network of Community Health Centers in Philadelphia, PA

Authors: Catelyn Coyle, Helena Kwakwa

Abstract:

Objective: As novel and better tolerated therapies become available, effective HCV testing and care models become increasingly necessary to not only identify individuals with active infection but also link them to HCV providers for medical evaluation and treatment. Our aim is to describe an effective HCV testing and linkage to care model piloted in a network of five community health centers located in Philadelphia, PA. Methods: In October 2012, National Nursing Centers Consortium piloted a routine opt-out HCV testing model in a network of community health centers, one of which treats HCV, HIV, and co-infected patients. Key aspects of the model were medical assistant initiated testing, the use of laboratory-based reflex test technology, and electronic medical record modifications to prompt, track, report and facilitate payment of test costs. Universal testing on all adult patients was implemented at health centers serving patients at high-risk for HCV. The other sites integrated high-risk based testing, where patients meeting one or more of the CDC testing recommendation risk factors or had a history of homelessness were eligible for HCV testing. Mid-course adjustments included the integration of dual HIV testing, development of a linkage to care coordinator position to facilitate the transition of HIV and/or HCV-positive patients from primary to specialist care, and the transition to universal HCV testing across all testing sites. Results: From October 2012 to June 2015, the health centers performed 7,730 HCV tests and identified 886 (11.5%) patients with a positive HCV-antibody test. Of those with positive HCV-antibody tests, 838 (94.6%) had an HCV-RNA confirmatory test and 590 (70.4%) progressed to current HCV infection (overall prevalence=7.6%); 524 (88.8%) received their RNA-positive test result; 429 (72.7%) were referred to an HCV care specialist and 271 (45.9%) were seen by the HCV care specialist. The best linkage to care results were seen at the test and treat the site, where of the 333 patients were current HCV infection, 175 (52.6%) were seen by an HCV care specialist. Of the patients with active HCV infection, 349 (59.2%) were unaware of their HCV-positive status at the time of diagnosis. Since the integration of dual HCV/HIV testing in September 2013, 9,506 HIV tests were performed, 85 (0.9%) patients had positive HIV tests, 81 (95.3%) received their confirmed HIV test result and 77 (90.6%) were linked to HIV care. Dual HCV/HIV testing increased the number of HCV tests performed by 362 between the 9 months preceding dual testing and first 9 months after dual testing integration, representing a 23.7% increment. Conclusion: Our HCV testing model shows that integrated routine testing and linkage to care is feasible and improved detection and linkage to care in a primary care setting. We found that prevalence of current HCV infection was higher than that seen in locally in Philadelphia and nationwide. Intensive linkage services can increase the number of patients who successfully navigate the HCV treatment cascade. The linkage to care coordinator position is an important position that acts as a trusted intermediary for patients being linked to care.

Keywords: HCV, routine testing, linkage to care, community health centers

Procedia PDF Downloads 342
11043 Challenges in the Last Mile of the Global Guinea Worm Eradication Program: A Systematic Review

Authors: Getahun Lemma

Abstract:

Introduction Guinea Worm Disease (GWD), also known as dracunculiasisis, is one of the oldest diseases in the history of mankind. Dracunculiasis is caused by a parasitic nematode, Dracunculus medinensis. Infection is acquired by drinking contaminated water with copepods containing infective Guinea Worm (GW) larvae). Almost one year after the infection, the worm usually emerges out through the skin on a lower, causing severe pain and disabilities. Although there is no effective drug or vaccine against the disease, the chain of transmission can be effectively prevented with simple and cost effective public health measures. Death due to dracunculiasis is very rare. However, it results in a wide range of physical, social and economic sequels. The disease is usually common in the rural, remote places of Sub-Saharan African countries among the marginalized societies. Currently, GWD is one of the neglected tropical diseases, which is on the verge of eradication. The global Guinea Worm Eradication Program (GWEP) was started in 1980. Since then, the program has achieved a tremendous success in reducing the global burden and number of GW case from 3.5 million to only 28 human cases at the end of 2018. However, it has recently been shown that not only humans can become infected, with a total of 1,105 animal infections have been reported at the end of 2018. Therefore, the objective of this study was to identify the existing challenges in the last mile of the GWEP in order To inform Policy makers and stakeholders on potential measures to finally achieve eradication. Method Systematic literature review on articles published from January 1, 2000 until May 30, 2019. Papers listed in Cochrane Library, Google Scholar, ProQuest PubMed and Web of Science databases were searched and reviewed. Results Twenty-five articles met inclusion criteria of the study and were selected for analysis. Hence, relevant data were extracted, grouped and descriptively analyzed. Results showed the main challenges complicating the last mile of global GWEP: 1. Unusual mode of transmission; 2. Rising animal Guinea Worm infection; 3. Suboptimal surveillance; 4. Insecurity; 5. Inaccessibility; 6. Inadequate safe water points; 7. Migration; 8. Poor case containment measures, 9. Ecological changes; and 10. New geographic foci of the disease. Conclusion This systematic review identified that most of the current challenges in the GWEP have been present since the start of the campaign. However, the recent change in epidemiological patterns and nature of GWD in the last remaining endemic countries illustrates a new twist in the global GWEP. Considering the complex nature of the current challenges, there seems to be a need for a more coordinated and multidisciplinary approach of GWD prevention and control measures in the last mile of the campaign. These new strategies would help to make history by eradicating dracunculiasis as the first ever parasitic disease.

Keywords: dracunculiasis, eradication program, guinea worm, last mile

Procedia PDF Downloads 110
11042 Clinical Study of the Prunus dulcis (Almond) Shell Extract on Tinea capitis Infection

Authors: Nasreen Thebo, W. Shaikh, A. J. Laghari, P. Nangni

Abstract:

Prunus dulcis (Almond) shell extract is demonstrated for its biomedical applications. Shell extract prepared by soxhlet method and further characterized by UV-Visible spectrophotometer, atomic absorption spectrophotometer (AAS), FTIR, GC-MS techniques. In this study, the antifungal activity of almond shell extract was observed against clinically isolated pathogenic fungi by strip method. The antioxidant potential of crude shell extract of was evaluated by using DPPH (2-2-diphenyl-1-picryhydrazyl) and radical scavenging system. The possibility of short term therapy was only 20 days. The total antioxidant activity varied from 94.38 to 95.49% and total phenolic content was found as 4.455 mg/gm in almond shell extract. Finally the results provide a great therapeutic potential against Tinea capitis infection of scalp. Included in this study of shell extract that show scientific evidence for clinical efficacy, as well as found to be more useful in the treatment of dermatologic disorders and without any doubt it can be recommended to be Patent.

Keywords: Tinea capitis, DPPH, FTIR, GC-MS therapeutic treatment

Procedia PDF Downloads 361
11041 A Strategy of Direct Power Control for PWM Rectifier Reducing Ripple in Instantaneous Power

Authors: T. Mohammed Chikouche, K. Hartani

Abstract:

Based on the analysis of basic direct torque control, a parallel master slave for four in-wheel permanent magnet synchronous motors (PMSM) fed by two three phase inverters used in electric vehicle is proposed in this paper. A conventional system with multi-inverter and multi-machine comprises a three phase inverter for each machine to be controlled. Another approach consists in using only one three-phase inverter to supply several permanent magnet synchronous machines. A modified direct torque control (DTC) algorithm is used for the control of the bi-machine traction system. Simulation results show that the proposed control strategy is well adapted for the synchronism of this system and provide good speed tracking performance.

Keywords: electric vehicle, multi-machine single-inverter system, multi-machine multi-inverter control, in-wheel motor, master-slave control

Procedia PDF Downloads 204
11040 X̄ and S Control Charts based on Weighted Standard Deviation Method

Authors: Derya Karagöz

Abstract:

A Shewhart chart based on normality assumption is not appropriate for skewed distributions since its Type-I error rate is inflated. This study presents X̄ and S control charts for monitoring the process variability for skewed distributions. We propose Weighted Standard Deviation (WSD) X̄ and S control charts. Standard deviation estimator is applied to monitor the process variability for estimating the process standard deviation, in the case of the W SD X̄ and S control charts as this estimator is simple and easy to compute. Unlike the Shewhart control chart, the proposed charts provide asymmetric limits in accordance with the direction and degree of skewness to construct the upper and lower limits. The performances of the proposed charts are compared with other heuristic charts for skewed distributions by using Simulation study. The Simulation studies show that the proposed control charts have good properties for skewed distributions and large sample sizes.

Keywords: weighted standard deviation, MAD, skewed distributions, S control charts

Procedia PDF Downloads 381
11039 Static Output Feedback Control of a Two-Wheeled Inverted Pendulum Using Sliding Mode Technique

Authors: Yankun Yang, Xinggang Yan, Konstantinos Sirlantzis, Gareth Howells

Abstract:

This paper presents a static output feedback sliding mode control method to regulate a two-wheeled inverted pendulum system with considerations of matched and unmatched uncertainties. A sliding surface is designed and the associated sliding motion stability is analysed based on the reduced-order dynamics. A static output sliding mode control law is synthesised to drive the system to the sliding surface and maintain a sliding motion afterwards. The nonlinear bounds on the uncertainties are employed in the stability analysis and control design to improve the robustness. The simulation results demonstrate the effectiveness of the proposed control.

Keywords: two-wheeled inverted pendulum, output feedback sliding mode control, nonlinear systems, robotics

Procedia PDF Downloads 233
11038 Effect of Two Entomopathogenic Fungi Beauveria bassiana and Metarhizium anisopliae var. acridum on the Haemolymph of the Desert Locust Schistocerca gregaria

Authors: Fatima Zohra Bissaad, Farid Bounaceur, Nassima Behidj, Nadjiba Chebouti, Fatma Halouane, Bahia Doumandji-Mitiche

Abstract:

Effect of Beauveria bassiana and Metarhizium anisopliae var. acridum on the 5th instar nymphs of Schistocerca gregaria was studied in the laboratory. Infection by these both entomopathogenic fungi caused reduction in the hemolymph total protein. The average amounts of total proteins were 2.3, 2.07, 2.09 µg/100 ml of haemolymph in the control and M. anisopliae var. acridum, and B. bassiana based-treatments, respectively. Three types of haemocytes were recognized and identified as prohaemocytes, plasmatocytes and granulocytes. The treatment caused significant reduction in the total haemocyte count and in each haemocyte type on the 9th day after its application.

Keywords: Beauveria bassiana, haemolymph picture, haemolymph protein, Metarhizium anisopliae var. acridum, Schistocerca gregaria

Procedia PDF Downloads 459
11037 Haematological Changes and Anticoccidial Activities of Kaempferol in Eimeria Tenella Infected Broiler Chickens

Authors: Ya'u Muhammad, Umar Umar A. Mallammadori, Dahiru Mansur

Abstract:

Effect of kaempferol on haematological parameters in two weeks old broiler chickens with experimental Eimeria tenella infection was evaluated in this study. Sixty-day old broilers were randomly allotted into six groups (I-VI) of ten broilers each and brooded for two weeks with commercial broiler feed (vital feed®) and provided water ad libitum. At two weeks of age broilers in group 1 were neither infected nor treated. Broilers in groups II-VI were infected with Eimeria tenella sporulated oocyst (104/ml) via oral inoculation. After infection was established, broilers in groups II-IV were treated orally with 1 mg/kg, 1.5 mg/kg, and 2 mg/kg of kaempferol, respectively. Broilers in group V were treated for five days with amprolium, 1.25 g/L in drinking water. Broilers in group VI were administered normal saline, 5 ml/kg per os for five days. Five days post infection; all broilers were sacrificed by severing their jugular veins. Blood sample from each bird was collected in EDTA container for haematology. Caecal contents were harvested and used to determine the lesion score and caecal Oocyst count respectively. Data obtained was analyzed using pad prism version 5.0. Mean Packed Cell Volume (PCV), haemoglobin (Hb) concentration, and Red Blood Cell (RBC) count significantly (P < 0.05) increased in groups II, III, and IV in a dose dependent manner. Similarly, PCV, Hb concentration, and RBC count significantly (P < 0.05) increased in groups II, III, and IV when compared to VI. No significant (P > 0.05) difference in the mean values of PCV, Hb and RBC count were recorded between groups treated with kaempferol and group V. Caecal Oocyst counts and lesion scores reduced significantly (P < 0.05) in groups II, III, and IV in a dose dependent manner. It was therefore observed in this study that kaempferol improved haematological parameters and reduced Oocyst count as well as the lesion scores in broilers infected with Eimeria tenella.

Keywords: broilers, Eimeria tenella, kaempferol, lesion scores, oocyst count,

Procedia PDF Downloads 166
11036 Predictive Functional Control with Disturbance Observer for Tendon-Driven Balloon Actuator

Authors: Jun-ya Nagase, Toshiyuki Satoh, Norihiko Saga, Koichi Suzumori

Abstract:

In recent years, Japanese society has been aging, engendering a labour shortage of young workers. Robots are therefore expected to perform tasks such as rehabilitation, nursing elderly people, and day-to-day work support for elderly people. The pneumatic balloon actuator is a rubber artificial muscle developed for use in a robot hand in such environments. This actuator has a long stroke, and a high power-to-weight ratio compared with the present pneumatic artificial muscle. Moreover, the dynamic characteristics of this actuator resemble those of human muscle. This study evaluated characteristics of force control of balloon actuator using a predictive functional control (PFC) system with disturbance observer. The predictive functional control is a model-based predictive control (MPC) scheme that predicts the future outputs of the actual plants over the prediction horizon and computes the control effort over the control horizon at every sampling instance. For this study, a 1-link finger system using a pneumatic balloon actuator is developed. Then experiments of PFC control with disturbance observer are performed. These experiments demonstrate the feasibility of its control of a pneumatic balloon actuator for a robot hand.

Keywords: disturbance observer, pneumatic balloon, predictive functional control, rubber artificial muscle

Procedia PDF Downloads 435
11035 Insulin Resistance in Patients with Chronic Hepatitis C Virus Infection: Upper Egypt Experience

Authors: Ali Kassem

Abstract:

Background: In the last few years, factors such as insulin resistance (IR) and hepatic steatosis have been linked to progression of hepatic fibrosis.Patients with chronic liver disease, and cirrhosis in particular, are known to be prone to IR. However, chronic HCV (hepatitis C) infection may induce IR, regardless of the presence of liver cirrhosis. Our aims are to study insulin resistance (IR) assessed by HOMA-IR (Homeostatic Model Assessment Insulin Resistance) as a possible risk factor in disease progression in cirrhotic patients and to evaluate the role of IR in hepatic fibrosis progression. The correlations of HOMA-IR values to laboratory, virological and histopathological parameters of chronic HCV are also examined. Methods: The study included 50 people divided into 30 adult chronic hepatitis C patients diagnosed by PCR (polymerase chain reaction) within previous 6 months and 20 healthy controls. The functional and morphological status of the liver were evaluated by ultrasonography and laboratory investigations including liver function tests and by liver biopsy. Fasting blood glucose and fasting insulin levels were measured and body mass index and insulin resistance were calculated. Patients having HOMA-IR >2.5 were labeled as insulin resistant. Results: Chronic hepatitis C patients with IR showed significantly higher mean values of BMI (body mass index) and fasting insulin than those without IR (P < 0.000). Patients with IR were more likely to have steatosis (p = 0.006), higher necroinflammatory activity (p = 0.05). No significant differences were found between the two groups regarding hepatic fibrosis. Conclusion: HOMA-IR measurement could represent a novel marker to identify the cirrhotic patients at greater risk for the progression of liver disease. As IR is a potentially modifiable risk factor, these findings may have important prognostic and therapeutic implications. Assessment of IR by HOMA-IR and improving insulin sensitivity are recommended in patients with HCV and related chronic liver disease.

Keywords: hepatic fibrosis, hepatitis C virus infection, hepatic steatosis, insulin resistance

Procedia PDF Downloads 137
11034 Nonlinear Adaptive PID Control for a Semi-Batch Reactor Based on an RBF Network

Authors: Magdi. M. Nabi, Ding-Li Yu

Abstract:

Control of a semi-batch polymerization reactor using an adaptive radial basis function (RBF) neural network method is investigated in this paper. A neural network inverse model is used to estimate the valve position of the reactor; this method can identify the controlled system with the RBF neural network identifier. The weights of the adaptive PID controller are timely adjusted based on the identification of the plant and self-learning capability of RBFNN. A PID controller is used in the feedback control to regulate the actual temperature by compensating the neural network inverse model output. Simulation results show that the proposed control has strong adaptability, robustness and satisfactory control performance and the nonlinear system is achieved.

Keywords: Chylla-Haase polymerization reactor, RBF neural networks, feed-forward, feedback control

Procedia PDF Downloads 684
11033 A Prospective Study on the Pattern of Antibiotics Use and Prevalence of Multidrug Resistant Escherichia Coli in Poultry Chickens and Its Correlation with Urinary Tract Infection

Authors: Stelvin Sebastian, Andriya Annie Tom, Joyalanna Babu, Merin Joshy

Abstract:

Introduction: The worldwide increase in the use of antibiotics in poultry and livestock industry to treat and prevent bacterial diseases and as growth promoters in feeds has led to the problem of development of antibiotic resistance both in animals and human population. Aim: To study the pattern of antibiotic use and prevalence of multidrug-resistant Escherichia coli in poultry chickens in selected farms in Muvattupuzha and to compare the spread of multidrug-resistant bacteria from poultry environment to UTI patients. Methodology: Two farms from each of 6 localities in Muvattupuzha were selected. A questionnaire on the pattern of antibiotic use and various farming practices were surveyed from farms. From each farm, 60samples of fresh fecal matter, litter from inside, litter from the outside shed, agricultural soil and control soil were collected, and antimicrobial susceptibility testing of E. coli was done. Antibiogram of UTI patients was collected from the secondary care hospital included in the study, and those were compared with resistance patterns of poultry samples. Results: From survey response antibiotics such as ofloxacin, enrofloxacin, levofloxacin, ciprofloxacin, colistin, ceftriaxone, neomycin, cephalexin, and oxytetracycline were used for treatment and prevention of infections in poultry. 31of 48 samples (51.66%) showed E. coli growth. 7 of 15 antibiotics (46.6%) showed resistance. Ampicillin, amoxicillin, meropenem, tetracycline showed 100% resistance to all samples. Statistical analysis confirmed similar resistance pattern in the poultry environment and UTI patients for antibiotics such as ampicillin, amoxicillin, amikacin, and ofloxacin. Conclusion: E. coli were resistant not only to extended-spectrum beta-lactams but also to carbapenems, which may be disseminated to the environment where litter was used as manure. This may due to irrational use of antibiotics in chicken or from their use in poultry feed as growth promoters. The study concludes the presence of multidrug-resistant E.coli in poultry and its spread to environment and humans, which may cause potentially serious implications for human health.

Keywords: multidrug resistance, escherichia coli, urinary tract infection, poultry

Procedia PDF Downloads 132
11032 An Enhanced AODV Routing Protocol for Wireless Sensor and Actuator Networks

Authors: Apidet Booranawong, Wiklom Teerapabkajorndet

Abstract:

An enhanced ad-hoc on-demand distance vector routing (E-AODV) protocol for control system applications in wireless sensor and actuator networks (WSANs) is proposed. Our routing algorithm is designed by considering both wireless network communication and the control system aspects. Control system error and network delay are the main selection criteria in our routing protocol. The control and communication performance is evaluated on multi-hop IEEE 802.15.4 networks for building-temperature control systems. The Gilbert-Elliott error model is employed to simulate packet loss in wireless networks. The simulation results demonstrate that the E-AODV routing approach can significantly improve the communication performance better than an original AODV routing under various packet loss rates. However, the control performance result by our approach is not much improved compared with the AODV routing solution.

Keywords: WSANs, building temperature control, AODV routing protocol, control system error, settling time, delay, delivery ratio

Procedia PDF Downloads 321
11031 Control of Sensors in Metering System of Fluid

Authors: A. Harrouz, O. Harrouz, A. Benatiallah

Abstract:

This paper is to review the essential definitions, roles, and characteristics of communication of metering system. We discuss measurement, data acquisition, and metrological control of a signal sensor from dynamic metering system. After that, we present control of instruments of metering system of fluid with more detailed discussions to the reference standards.

Keywords: data acquisition, dynamic metering system, reference standards, metrological control

Procedia PDF Downloads 477
11030 Flexible Arm Manipulator Control for Industrial Tasks

Authors: Mircea Ivanescu, Nirvana Popescu, Decebal Popescu, Dorin Popescu

Abstract:

This paper addresses the control problem of a class of hyper-redundant arms. In order to avoid discrepancy between the mathematical model and the actual dynamics, the dynamic model with uncertain parameters of this class of manipulators is inferred. A procedure to design a feedback controller which stabilizes the uncertain system has been proposed. A PD boundary control algorithm is used in order to control the desired position of the manipulator. This controller is easy to implement from the point of view of measuring techniques and actuation. Numerical simulations verify the effectiveness of the presented methods. In order to verify the suitability of the control algorithm, a platform with a 3D flexible manipulator has been employed for testing. Experimental tests on this platform illustrate the applications of the techniques developed in the paper.

Keywords: distributed model, flexible manipulator, observer, robot control

Procedia PDF Downloads 306
11029 Performences of Type-2 Fuzzy Logic Control and Neuro-Fuzzy Control Based on DPC for Grid Connected DFIG with Fixed Switching Frequency

Authors: Fayssal Amrane, Azeddine Chaiba

Abstract:

In this paper, type-2 fuzzy logic control (T2FLC) and neuro-fuzzy control (NFC) for a doubly fed induction generator (DFIG) based on direct power control (DPC) with a fixed switching frequency is proposed for wind generation application. First, a mathematical model of the doubly-fed induction generator implemented in d-q reference frame is achieved. Then, a DPC algorithm approach for controlling active and reactive power of DFIG via fixed switching frequency is incorporated using PID. The performance of T2FLC and NFC, which is based on the DPC algorithm, are investigated and compared to those obtained from the PID controller. Finally, simulation results demonstrate that the NFC is more robust, superior dynamic performance for wind power generation system applications.

Keywords: doubly fed induction generator (DFIG), direct power control (DPC), neuro-fuzzy control (NFC), maximum power point tracking (MPPT), space vector modulation (SVM), type 2 fuzzy logic control (T2FLC)

Procedia PDF Downloads 401
11028 Modeling and Control of an Acrobot Using MATLAB and Simulink

Authors: Dong Sang Yoo

Abstract:

The problem of finding control laws for underactuated systems has attracted growing attention since these systems are characterized by the fact that they have fewer actuators than the degrees of freedom to be controlled. The acrobot, which is a planar two-link robotic arm in the vertical plane with an actuator at the elbow but no actuator at the shoulder, is a representative of underactuated systems. In this paper, the dynamic model of the acrobot is implemented using Mathworks’ Simscape. And the sliding mode control is constructed using MATLAB and Simulink.

Keywords: acrobot, MATLAB and simulink, sliding mode control, underactuated system

Procedia PDF Downloads 773
11027 Comprehensive Literature Review of the Humanistic Burden of Clostridium (Clostridiodes) difficile Infection

Authors: Caroline Seo, Jennifer Stephens, Kirstin H. Heinrich

Abstract:

Background: Clostridiodes (formerly Clostridium) difficile infection (CDI) is an anaerobic, spore-forming bacterium with manifestations including diarrhea, pseudomembranous colitis and toxic megacolon. Despite general understanding that CDI may be associated with marked burden on patients’ health, there has been limited information available on the humanistic burden of CDI. The objective of this literature review was to summarize the published data on the humanistic burden of CDI globally, in order to better inform future research efforts and increase awareness of the patient perspective in this disease. Methods: A comprehensive literature review of the past 15 years (2002-2017) was conducted using MEDLINE, Embase and Cumulative Index of Nursing and Allied Health Literature. Additional searches were conducted from conference proceedings (2015-2017). Articles selected were studies specifically designed to examine the humanistic burden of illness associated with adult patients with CDI. Results: Of 3,325 articles or abstracts identified, 33 remained after screening and full text review. Sixty percent (60%) were published in 2016 or 2017. Data from the United States or Western Europe were most common. Data from Brazil, Canada, China and Spain also exist. Thirteen (13) studies used validated patient-reported outcomes instruments, mostly EQ-5D utility and SF-36 generic instruments. Three (3) studies used CDI-specific instruments (CDiff32, CDI-DaySyms). The burden of CDI impacts patients in multiple health-related quality of life (HRQOL) domains. SF-36 domains with the largest decrements compared to other GI diarrheal diseases (IBS-D and Crohn’s) were role physical, physical functioning, vitality, social functioning, and role emotional. Reported EQ-5D utilities for CDI ranged from 0.35-0.42 compared to 0.65 in Crohn’s and 0.72 in IBS-D. The majority of papers addressed physical functioning and mental health domains (67% for both). Across various studies patients reported weakness, lack of appetite, sleep disturbance, functional dependence, and decreased activities of daily lives due to the continuous diarrhea. Due to lack of control over this infection, CDI also impacts the psychological and emotional quality of life of the patients. Patients reported feelings of fear, anxiety, frustration, depression, and embarrassment. Additionally, the type of disease (primary vs. recurrent) may impact mental health. One study indicated that there is a decrement in SF-36 mental scores in patients with recurrent CDI, in comparison to patients with primary CDI. Other domains highlighted by these studies include pain (27%), social isolation (27%), vitality and fatigue (24%), self-care (9%), and caregiver burden (0%). Two studies addressed work productivity, with 1 of these studies reporting that CDI patients had the highest work productivity and activity impairment scores among the gastrointestinal diseases. No study specifically included caregiver self-report. However, 3 studies did provide mention of patients’ worry on how their diagnosis of CDI would impact family, caregivers, and/or friends. Conclusions: Despite being a serious public health issue there has been a paucity of research on the HRQOL among those with CDI. While progress is being made, gaps exist in understanding the burden on patients, caregivers, and families. Future research is warranted to aid understanding of the CDI patient perspective.

Keywords: burden, Clostridiodes, difficile, humanistic, infection

Procedia PDF Downloads 116
11026 Human Immuno-Deficiency Virus Co-Infection with Hepatitis B Virus and Baseline Cd4+ T Cell Count among Patients Attending a Tertiary Care Hospital, Nepal

Authors: Soma Kanta Baral

Abstract:

Background: Since 1981, when the first AIDS case was reported, worldwide, more than 34 million people have been infected with HIV. Almost 95 percent of the people infected with HIV live in developing countries. As HBV & HIV share similar routes of transmission by sexual intercourse or drug use by parenteral injection, co-infection is common. Because of the limited access to healthcare & HIV treatment in developing countries, HIV-infected individuals are present late for care. Enumeration of CD4+ T cell count at the time of diagnosis has been useful to initiate the therapy in HIV infected individuals. The baseline CD4+ T cell count shows high immunological variability among patients. Methods: This prospective study was done in the serology section of the Department of Microbiology over a period of one year from august 2012 to July 2013. A total of 13037 individuals subjected for HIV test were included in the study comprising of 4982 males & 8055 females. Blood sample was collected by vein puncture aseptically with standard operational procedure in clean & dry test-tube. All blood samples were screened for HIV as described by WHO algorithm by Immuno-chromatography rapid kits. Further confirmation was done by biokit ELISA method as per the manufacturer’s guidelines. After informed consent, HIV positive individuals were screened for HBsAg by Immuno-chromatography rapid kits (Hepacard). Further confirmation was done by biokit ELISA method as per the manufacturer’s guidelines. EDTA blood samples were collected from the HIV sero-positive individuals for baseline CD4+ T count. Then, CD4+ T cells count was determined by using FACS Calibur Flow Cytometer (BD). Results: Among 13037 individuals screened for HIV, 104 (0.8%) were found to be infected comprising of 69(66.34%) males & 35 (33.65%) females. The study showed that the high infection was noted in housewives (28.7%), active age group (30.76%), rural area (56.7%) & in heterosexual route (80.9%) of transmission. Out of total HIV infected individuals, distribution of HBV co-infection was found to be 6(5.7%). All co- infected individuals were married, male, above the age of 25 years & heterosexual route of transmission. Baseline CD4+ T cell count of HIV infected patient was found higher (mean CD4+ T cell count; 283cells/cu.mm) than HBV co-infected patients (mean CD4+ T cell count; 91 cells/cu.mm). Majority (77.2%) of HIV infected & all co-infected individuals were presented in our center late (CD4+ T cell count;< 350/cu. mm) for diagnosis and care. Majority of co- infected 4 (80%) were late presented with advanced AIDS stage (CD4+ count; <200/cu.mm). Conclusions: The study showed a high percentage of HIV sero-positive & co- infected individuals. Baseline CD4+ T cell count of majority of HIV infected individuals was found to be low. Hence, more sustained and vigorous awareness campaigns & counseling still need to be done in order to promote early diagnosis and management.

Keywords: HIV/AIDS, HBsAg, co-infection, CD4+

Procedia PDF Downloads 199
11025 Optimal Voltage and Frequency Control of a Microgrid Using the Harmony Search Algorithm

Authors: Hossein Abbasi

Abstract:

The stability is an important topic to plan and manage the energy in the microgrids as the same as the conventional power systems. The voltage and frequency stability is one of the most important issues recently studied in microgrids. The objectives of this paper are the modelling and designing of the components and optimal controllers for the voltage and frequency control of the AC/DC hybrid microgrid under the different disturbances. Since the PI controllers have the advantages of simple structure and easy implementation, so they are designed and modeled in this paper. The harmony search (HS) algorithm is used to optimize the controllers’ parameters. According to the achieved results, the PI controllers have a good performance in voltage and frequency control of the microgrid.

Keywords: frequency control, HS algorithm, microgrid, PI controller, voltage control

Procedia PDF Downloads 374
11024 Piezoelectric based Passive Vibration Control of Composite Turbine Blade using Shunt Circuit

Authors: Kouider Bendine, Zouaoui Satla, Boukhoulda Farouk Benallel, Shun-Qi Zhang

Abstract:

Turbine blades are subjected to a variety of loads, lead to an undesirable vibration. Such vibration can cause serious damages or even lead to a total failure of the blade. The present paper addresses the vibration control of turbine blade. The study aims to propose a passive vibration control using piezoelectric material. the passive control is effectuated by shunting an RL circuit to the piezoelectric patch in a parallel configuration. To this end, a Finite element model for the blade with the piezoelectric patch is implemented in ANSYS APDL. The model is then subjected to a harmonic frequency-based analysis for the case of control on and off. The results show that the proposed methodology was able to reduce blade vibration by 18%.

Keywords: blade, active piezoelectric vibration control, finite element., shunt circuit

Procedia PDF Downloads 80
11023 In vivo Estimation of Mutation Rate of the Aleutian Mink Disease Virus

Authors: P.P. Rupasinghe, A.H. Farid

Abstract:

The Aleutian mink disease virus (AMDV, Carnivore amdoparvovirus 1) causes persistent infection, plasmacytosis, and formation and deposition of immune complexes in various organs in adult mink, leading to glomerulonephritis, arteritis and sometimes death. The disease has no cure nor an effective vaccine, and identification and culling of mink positive for anti-AMDV antibodies have not been successful in controlling the infection in many countries. The failure to eradicate the virus from infected farms may be caused by keeping false-negative individuals on the farm, virus transmission from wild animals, or neighboring farms. The identification of sources of infection, which can be performed by comparing viral sequences, is important in the success of viral eradication programs. High mutation rates could cause inaccuracies when viral sequences are used to trace back an infection to its origin. There is no published information on the mutation rate of AMDV either in vivo or in vitro. The in vivo estimation is the most accurate method, but it is difficult to perform because of the inherent technical complexities, namely infecting live animals, the unknown numbers of viral generations (i.e., infection cycles), the removal of deleterious mutations over time and genetic drift. The objective of this study was to determine the mutation rate of AMDV on which no information was available. A homogenate was prepared from the spleen of one naturally infected American mink (Neovison vison) from Nova Scotia, Canada (parental template). The near full-length genome of this isolate (91.6%, 4,143 bp) was bidirectionally sequenced. A group of black mink was inoculated with this homogenate (descendant mink). Spleen sampled were collected from 10 descendant mink after 16 weeks post-inoculation (wpi) and from anther 10 mink after 176 wpi, and their near-full length genomes were bi-directionally sequenced. Sequences of these mink were compared with each other and with the sequence of the parental template. The number of nucleotide substitutions at 176 wpi was 3.1 times greater than that at 16 wpi (113 vs 36) whereas the estimates of mutation rate at 176 wpi was 3.1 times lower than that at 176 wpi (2.85×10-3 vs 9.13×10-4 substitutions/ site/ year), showing a decreasing trend in the mutation rate per unit of time. Although there is no report on in vivo estimate of the mutation rate of DNA viruses in animals using the same method which was used in the current study, these estimates are at the higher range of reported values for DNA viruses determined by various techniques. These high estimates are logical based on the wide range of diversity and pathogenicity of AMDV isolates. The results suggest that increases in the number of nucleotide substitutions over time and subsequent divergence make it difficult to accurately trace back AMDV isolates to their origin when several years elapsed between the two samplings.

Keywords: Aleutian mink disease virus, American mink, mutation rate, nucleotide substitution

Procedia PDF Downloads 108
11022 A Simulated Evaluation of Model Predictive Control

Authors: Ahmed AlNouss, Salim Ahmed

Abstract:

Process control refers to the techniques to control the variables in a process in order to maintain them at their desired values. Advanced process control (APC) is a broad term within the domain of control where it refers to different kinds of process control and control related tools, for example, model predictive control (MPC), statistical process control (SPC), fault detection and classification (FDC) and performance assessment. APC is often used for solving multivariable control problems and model predictive control (MPC) is one of only a few advanced control methods used successfully in industrial control applications. Advanced control is expected to bring many benefits to the plant operation; however, the extent of the benefits is plant specific and the application needs a large investment. This requires an analysis of the expected benefits before the implementation of the control. In a real plant simulation studies are carried out along with some experimentation to determine the improvement in the performance of the plant due to advanced control. In this research, such an exercise is undertaken to realize the needs of APC application. The main objectives of the paper are as follows: (1) To apply MPC to a number of simulations set up to realize the need of MPC by comparing its performance with that of proportional integral derivatives (PID) controllers. (2) To study the effect of controller parameters on control performance. (3) To develop appropriate performance index (PI) to compare the performance of different controller and develop novel idea to present tuning map of a controller. These objectives were achieved by applying PID controller and a special type of MPC which is dynamic matrix control (DMC) on the multi-tanks process simulated in loop-pro. Then the controller performance has been evaluated by changing the controller parameters. This performance was based on special indices related to the difference between set point and process variable in order to compare the both controllers. The same principle was applied for continuous stirred tank heater (CSTH) and continuous stirred tank reactor (CSTR) processes simulated in Matlab. However, in these processes some developed programs were written to evaluate the performance of the PID and MPC controllers. Finally these performance indices along with their controller parameters were plotted using special program called Sigmaplot. As a result, the improvement in the performance of the control loops was quantified using relevant indices to justify the need and importance of advanced process control. Also, it has been approved that, by using appropriate indices, predictive controller can improve the performance of the control loop significantly.

Keywords: advanced process control (APC), control loop, model predictive control (MPC), proportional integral derivatives (PID), performance indices (PI)

Procedia PDF Downloads 393
11021 Control of an Outbreak of Vancomycin-Resistant Enterococci in a Tunisian Teaching Hospital

Authors: Hela Ghali, Sihem Ben Fredj, Mohamed Ben Rejeb, Sawssen Layouni, Salwa Khefacha, Lamine Dhidah, Houyem Said Laatiri

Abstract:

Background: Antimicrobial resistance is a growing threat to public health and motivates to improve prevention and control programs both at international (WHO) and national levels. Despite their low pathogenicity, vancomycin-resistant enterococci (VRE) are common nosocomial pathogens in several countries. The high potential for transmission of VRE between patients and the threat to send its resistance genes to other bacteria such as staphylococcus aureus already resistant to meticilin, justify strict control measures. Indeed, in Europe, the proportion of Enterococcus faecium responsible for invasive infections, varies from 1% to 35% in 2011 and less than 5% were resistant to vancomycin. In addition, it represents the second cause of urinary tract and wound infections and the third cause of nosocomial bacteremia in the United States. The nosocomial outbreaks of VRE have been mainly described in intensive care services, hematology-oncology and haemodialysis. An epidemic of VRE has affected our hospital and the objective of this work is to describe the measures put in place. Materials/Methods: Following the alert given by the service of plastic surgery concerning a patient carrier of VRE, a team of the prevention and healthcare security service (doctor + technician) made an investigation. A review of files was conducted to draw the synoptic table and the table of cases. Results: By contacting the microbiology laboratory, we have identified four other cases of VRE and who were hospitalized in Medical resuscitation department (2 cases, one of them was transferred to the Physical rehabilitation department), and Nephrology department (2 cases). The visit has allowed to detect several malfunctions in professional practice. A crisis cell has allowed to validate, coordinate and implement control measures following the recommendations of the Technical Center of nosocomial infections. In fact, the process was to technically isolate cases in their sector of hospitalization, to restrict the use of antibiotics, to strength measures of basic hygiene, and to make a screening by rectal swab for both cases and contacts (other patients and health staff). These measures have helped to control the situation and no other case has been reported for a month. 2 new cases have been detected in the intensive care unit after a month. However, these are short-term strategies, and other measures in the medium and long term should be taken into account in order to face similar outbreaks. Conclusion: The efforts to control the outbreak were not efficient since 2 new cases have been reported after a month. Therefore, a continuous monitoring in order to detect new cases earlier is crucial to minimize the dissemination of VRE.

Keywords: hospitals, nosocomial infection, outbreak, vancomycin-resistant enterococci

Procedia PDF Downloads 283