Search results for: robotic resection
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 391

Search results for: robotic resection

361 Non Immersive Virtual Laboratory Applied to Robotics Arms

Authors: Luis F. Recalde, Daniela A. Bastidas, Dayana E. Gallegos, Patricia N. Constante, Victor H. Andaluz

Abstract:

This article presents a non-immersive virtual lab-oratory to emulate the behavior of the Mitsubishi Melfa RV 2SDB robotic arm, allowing students and users to acquire skills and experience related to real robots, augmenting the access and learning of robotics in Universidad de las Fuerzas Armadas (ESPE). It was developed using the mathematical model of the robotic arm, thus defining the parameters for virtual recreation. The environment, interaction, and behavior of the robotic arm were developed in a graphic engine (Unity3D) to emulate learning tasks such as in a robotics laboratory. In the virtual system, four inputs were developed for the movement of the robot arm; further, to program the robot, a user interface was created where the user selects the trajectory such as point to point, line, arc, or circle. Finally, the hypothesis of the industrial robotic learning process is validated through the level of knowledge acquired after using the system.

Keywords: virtual learning, robot arm, non-immersive reality, mathematical model

Procedia PDF Downloads 69
360 Robotic Assisted vs Traditional Laparoscopic Partial Nephrectomy Peri-Operative Outcomes: A Comparative Single Surgeon Study

Authors: Gerard Bray, Derek Mao, Arya Bahadori, Sachinka Ranasinghe

Abstract:

The EAU currently recommends partial nephrectomy as the preferred management for localised cT1 renal tumours, irrespective of surgical approach. With the advent of robotic assisted partial nephrectomy, there is growing evidence that warm ischaemia time may be reduced compared to the traditional laparoscopic approach. There is still no clear differences between the two approaches with regards to other peri-operative and oncological outcomes. Current limitations in the field denote the lack of single surgeon series to compare the two approaches as other studies often include multiple operators of different experience levels. To the best of our knowledge, this study is the first single surgeon series comparing peri-operative outcomes of robotic assisted and laparoscopic PN. The current study aims to reduce intra-operator bias while maintaining an adequate sample size to assess the differences in outcomes between the two approaches. We retrospectively compared patient demographics, peri-operative outcomes, and renal function derangements of all partial nephrectomies undertaken by a single surgeon with experience in both laparoscopic and robotic surgery. Warm ischaemia time, length of stay, and acute renal function deterioration were all significantly reduced with robotic partial nephrectomy, compared to laparoscopic nephrectomy. This study highlights the benefits of robotic partial nephrectomy. Further prospective studies with larger sample sizes would be valuable additions to the current literature.

Keywords: partial nephrectomy, robotic assisted partial nephrectomy, warm ischaemia time, peri-operative outcomes

Procedia PDF Downloads 109
359 Development of Agricultural Robotic Platform for Inter-Row Plant: An Autonomous Navigation Based on Machine Vision

Authors: Alaa El-Din Rezk

Abstract:

In Egypt, management of crops still away from what is being used today by utilizing the advances of mechanical design capabilities, sensing and electronics technology. These technologies have been introduced in many places and recorm, for Straight Path, Curved Path, Sine Wave ded high accuracy in different field operations. So, an autonomous robotic platform based on machine vision has been developed and constructed to be implemented in Egyptian conditions as self-propelled mobile vehicle for carrying tools for inter/intra-row crop management based on different control modules. The experiments were carried out at plant protection research institute (PPRI) during 2014-2015 to optimize the accuracy of agricultural robotic platform control using machine vision in term of the autonomous navigation and performance of the robot’s guidance system. Results showed that the robotic platform' guidance system with machine vision was able to adequately distinguish the path and resisted image noise and did better than human operators for getting less lateral offset error. The average error of autonomous was 2.75, 19.33, 21.22, 34.18, and 16.69 mm. while the human operator was 32.70, 4.85, 7.85, 38.35 and 14.75 mm Path, Offset Discontinuity and Angle Discontinuity respectively.

Keywords: autonomous robotic, Hough transform, image processing, machine vision

Procedia PDF Downloads 277
358 Application of Robotics to Assemble a Used Fuel Container in the Canadian Used Fuel Packing Plant

Authors: Dimitrie Marinceu

Abstract:

The newest Canadian Used Fuel Container (UFC)- (called also “Mark II”) modifies the design approach for its Assembly Robotic Cell (ARC) in the Canadian Used (Nuclear) Fuel Packing Plant (UFPP). Some of the robotic design solutions are presented in this paper. The design indicates that robots and manipulators are expected to be used in the Canadian UFPP. As normally, the UFPP design will incorporate redundancy of all equipment to allow expedient recovery from any postulated upset conditions. Overall, this paper suggests that robot usage will have a significant positive impact on nuclear safety, quality, productivity, and reliability.

Keywords: used fuel packing plant, robotic assembly cell, used fuel container, deep geological repository

Procedia PDF Downloads 261
357 Design of Reconfigurable Supernumerary Robotic Limb Based on Differential Actuated Joints

Authors: Qinghua Zhang, Yanhe Zhu, Xiang Zhao, Yeqin Yang, Hongwei Jing, Guoan Zhang, Jie Zhao

Abstract:

This paper presents a wearable reconfigurable supernumerary robotic limb with differential actuated joints, which is lightweight, compact and comfortable for the wearers. Compared to the existing supernumerary robotic limbs which mostly adopted series structure with large movement space but poor carrying capacity, a prototype with the series-parallel configuration to better adapt to different task requirements has been developed in this design. To achieve a compact structure, two kinds of cable-driven mechanical structures based on guide pulleys and differential actuated joints were designed. Moreover, two different tension devices were also designed to ensure the reliability and accuracy of the cable-driven transmission. The proposed device also employed self-designed bearings which greatly simplified the structure and reduced the cost.

Keywords: cable-driven, differential actuated joints, reconfigurable, supernumerary robotic limb

Procedia PDF Downloads 183
356 Robotic Logging Technology: The Future of Oil Well Logging

Authors: Nitin Lahkar, Rishiraj Goswami

Abstract:

“Oil Well Logging” or the practice of making a detailed record (a well log) of the geologic formations penetrated by a borehole is an important practice in the Oil and Gas industry. Although a lot of research has been undertaken in this field, some basic limitations still exist. One of the main arenas or venues where plethora of problems arises is in logistically challenged areas. Accessibility and availability of efficient manpower, resources and technology is very time consuming, restricted and often costly in these areas. So, in this regard, the main challenge is to decrease the Non Productive Time (NPT) involved in the conventional logging process. The thought for the solution to this problem has given rise to a revolutionary concept called the “Robotic Logging Technology”. Robotic logging technology promises the advent of successful logging in all kinds of wells and trajectories. It consists of a wireless logging tool controlled from the surface. This eliminates the need for the logging truck to be summoned which in turn saves precious rig time. The robotic logging tool here, is designed such that it can move inside the well by different proposed mechanisms and models listed in the full paper as TYPE A, TYPE B and TYPE C. These types are classified on the basis of their operational technology, movement and conditions/wells in which the tool is to be used. Thus, depending on subsurface conditions, energy sources available and convenience the TYPE of Robotic model will be selected. Advantages over Conventional Logging Techniques: Reduction in Non-Productive time, lesser energy requirements, very fast action as compared to all other forms of logging, can perform well in all kinds of well trajectories (vertical/horizontal/inclined).

Keywords: robotic logging technology, innovation, geology, geophysics

Procedia PDF Downloads 270
355 Embedded Hardware and Software Design of Omnidirectional Autonomous Robotic Platform Suitable for Advanced Driver Assistance Systems Testing with Focus on Modularity and Safety

Authors: Ondrej Lufinka, Jan Kaderabek, Juraj Prstek, Jiri Skala, Kamil Kosturik

Abstract:

This paper deals with the problem of using Autonomous Robotic Platforms (ARP) for the ADAS (Advanced Driver Assistance Systems) testing in automotive. There are different possibilities of the testing already in development, and lately, the autonomous robotic platforms are beginning to be used more and more widely. Autonomous Robotic Platform discussed in this paper explores the hardware and software design possibilities related to the field of embedded systems. The paper focuses on its chapters on the introduction of the problem in general; then, it describes the proposed prototype concept and its principles from the embedded HW and SW point of view. It talks about the key features that can be used for the innovation of these platforms (e.g., modularity, omnidirectional movement, common and non-traditional sensors used for localization, synchronization of more platforms and cars together, or safety mechanisms). In the end, the future possible development of the project is discussed as well.

Keywords: advanced driver assistance systems, ADAS, autonomous robotic platform, embedded systems, hardware, localization, modularity, multiple robots synchronization, omnidirectional movement, safety mechanisms, software

Procedia PDF Downloads 112
354 Self-Propelled Intelligent Robotic Vehicle Based on Octahedral Dodekapod to Move in Active Branched Pipelines with Variable Cross-Sections

Authors: Sergey N. Sayapin, Anatoly P. Karpenko, Suan H. Dang

Abstract:

Comparative analysis of robotic vehicles for pipe inspection is presented in this paper. The promising concept of self-propelled intelligent robotic vehicle (SPIRV) based on octahedral dodekapod for inspection and operation in active branched pipelines with variable cross-sections is reasoned. SPIRV is able to move in pipeline, regardless of its spatial orientation. SPIRV can also be used to move along the outside of the pipelines as well as in space between surfaces of annular tubes. Every one of faces of the octahedral dodekapod can clamp/unclamp a thing with a closed loop surface of various forms as well as put pressure on environmental surface of contact. These properties open new possibilities for its applications in SPIRV. We examine design principles of octahedral dodekapod as future intelligent building blocks for various robotic vehicles that can self-move and self-reconfigure.

Keywords: Modular robot, octahedral dodekapod, pipe inspection robot, spatial parallel structure

Procedia PDF Downloads 478
353 Research of Control System for Space Intelligent Robot Based on Vision Servo

Authors: Changchun Liang, Xiaodong Zhang, Xin Liu, Pengfei Sun

Abstract:

Space intelligent robotic systems are expected to play an increasingly important role in the future. The robotic on-orbital service, whose key is the tracking and capturing technology, becomes research hot in recent years. In this paper, the authors propose a vision servo control system for target capturing. Robotic manipulator will be an intelligent robotic system with large-scale movement, functional agility, and autonomous ability, and it can be operated by astronauts in the space station or be controlled by the ground operator in the remote operation mode. To realize the autonomous movement and capture mission of SRM, a kind of autonomous programming strategy based on multi-camera vision fusion is designed and the selection principle of object visual position and orientation measurement information is defined for the better precision. Distributed control system hierarchy is designed and reliability is considering to guarantee the abilities of control system. At last, a ground experiment system is set up based on the concept of robotic control system. With that, the autonomous target capturing experiments are conducted. The experiment results validate the proposed algorithm, and demonstrates that the control system can fulfill the needs of function, real-time and reliability.

Keywords: control system, on-orbital service, space robot, vision servo

Procedia PDF Downloads 393
352 Role of Water Supply in the Functioning of the MLDB Systems

Authors: Ramanpreet Kaur, Upasana Sharma

Abstract:

The purpose of this paper is to address the challenges faced by MLDB system at the piston foundry plant due to interruption in supply of water. For the MLDB system to work in Model, two sub-units must be connected to the robotic main unit. The system cannot function without robotics and water supply by the fan (WSF). Insufficient water supply is the cause of system failure. The system operates at top performance using two sub-units. If one sub-unit fails, the system capacity is reduced. Priority of repair is given to the main unit i.e. Robotic and WSF. To solve the problem, semi-Markov process and regenerative point technique are used. Relevant graphs are also included to particular case.

Keywords: MLDB system, robotic, semi-Markov process, regenerative point technique

Procedia PDF Downloads 43
351 Haptic Robotic Glove for Tele-Exploration of Explosive Devices

Authors: Gizem Derya Demir, Ilayda Yankilic, Daglar Karamuftuoglu, Dante Dorantes

Abstract:

ABSTRACT HAPTIC ROBOTIC GLOVE FOR TELE-EXPLORATION OF EXPLOSIVE DEVICES Gizem Derya Demir, İlayda Yankılıç, Dağlar Karamüftüoğlu, Dante J. Dorantes-González Department of Mechanical Engineering, MEF University Ayazağa Cad. No.4, 34396 Maslak, Sarıyer, İstanbul, Turkey Nowadays, terror attacks are, unfortunately, a more common threat around the world. Therefore, safety measures have become much more essential. An alternative to providing safety and saving human lives is done by robots, such as disassembling and liquidation of bombs. In this article, remote exploration and manipulation of potential explosive devices from a safe-distance are addressed by designing a novel, simple and ergonomic haptic robotic glove. SolidWorks® Computer-Aided Design, computerized dynamic simulation, and MATLAB® kinematic and static analysis were used for the haptic robotic glove and finger design. Angle controls of servo motors were made using ARDUINO® IDE codes on a Makeblock® MegaPi control card. Simple grasping dexterity solutions for the fingers were obtained using one linear soft and one angle sensors for each finger, and six servo motors are used in total to remotely control a slave multi-tooled robotic hand. This project is still undergoing and presents current results. Future research steps are also presented.

Keywords: Dexterity, Exoskeleton, Haptics , Position Control, Robotic Hand , Teleoperation

Procedia PDF Downloads 142
350 Hybrid Deep Learning and FAST-BRISK 3D Object Detection Technique for Bin-Picking Application

Authors: Thanakrit Taweesoontorn, Sarucha Yanyong, Poom Konghuayrob

Abstract:

Robotic arms have gained popularity in various industries due to their accuracy and efficiency. This research proposes a method for bin-picking tasks using the Cobot, combining the YOLOv5 CNNs model for object detection and pose estimation with traditional feature detection (FAST), feature description (BRISK), and matching algorithms. By integrating these algorithms and utilizing a small-scale depth sensor camera for capturing depth and color images, the system achieves real-time object detection and accurate pose estimation, enabling the robotic arm to pick objects correctly in both position and orientation. Furthermore, the proposed method is implemented within the ROS framework to provide a seamless platform for robotic control and integration. This integration of robotics, cameras, and AI technology contributes to the development of industrial robotics, opening up new possibilities for automating challenging tasks and improving overall operational efficiency.

Keywords: robotic vision, image processing, applications of robotics, artificial intelligent

Procedia PDF Downloads 49
349 Swallowing Outcomes in Supraglottic Cancer Patients after Trans-Oral Robotic Surgery (TORS) Provided with Early Dysphagia Management Using Standardized Functional and Objective Measures

Authors: Hitesh Gupta, Surender Dabas

Abstract:

TORS is increasingly gaining widespread use and has been explored as minimally invasive surgery for the treatment of supraglottic cancer (SGC). Being a central critical role of Supraglottis in deglutition, swallowing outcomes post TORS remain a most important factor. Available published studies show inconsistent swallowing outcomes and are deficient in standardized outcome measures, description of swallowing recovery and rehabilitation. So, the objective of this study is to find out swallowing outcomes in SGC patients after TORS provided with early dysphagia management using standardized measures. Prospectively 16 patients were recruited in the study who underwent TORS for primary tumor of Supraglottis, involving one or more sub-sites or invading to sites other than Supraglottis at the BLK Super Specialty Hospital, New Delhi from March 2019 to June 2020. All patients were evaluated for dysphagia with subsequent swallowing rehabilitation on post operative day 3 in the hospital or at the time of discharge, whichever was earlier. Functional oral intake scale (FOIS) and penetration-aspiration score (PAS) were used as outcome measures to quantify swallowing recovery at one month and six month post operatively. Post TORS, patients achieved functional swallow in less than one month, where resection was limited to Supraglottis, while the recovery was delayed in patients with extended resection to tongue base or hypopharynx. Overall, out of Total 16 cases including all supraglottis sub-catagories, 13 (81%) could remove their NG tube (FOIS ≥5 and PAS=1 ) within 6 months. In which 8 cases(62%) achieved functional swallow in less than one month. Swallowing outcomes post TORS supraglottic laryngectomy are favorable if provided with early dysphagia management (or swallowing rehabilitation).

Keywords: dysphagia, supraglottic cancer, swallowing, TORS

Procedia PDF Downloads 86
348 The Role of Pulmonary Resection in Complicated Primary Pediatric Pulmonary Tuberculosis: An Evidence-Based Case Report

Authors: Hendra Wibowo, Suprayitno Wardoyo, Dhama Shinta

Abstract:

Introduction: Pediatric pulmonary tuberculosis (TB) incidence was increasing, with many undetected cases. In complicated TB, treatment should consist of returning pulmonary function, preventing further complications, and eliminating bacteria. Complicated TB management was still controversial, and surgery was one of the treatments that should be evaluated in accordance with its role in the treatment of complicated TB. Method: This study was an evidence-based case report. The database used for the literature search were Cochrane, Medline, Proquest, and ScienceDirect. Keywords for the search were ‘primary pulmonary tuberculosis’, ‘surgery’, ‘lung resection’, and ‘children’. Inclusion criteria were studies in English or Indonesian, with children under 18 years old as subject, and full-text articles available. The assessment was done according to Oxford Centre for evidence-based medicine 2011. Results: Six cohort studies were analyzed. Surgery was indicated for patients with complicated TB that were unresponsive towards treatment. It should be noted that the experiments were done before the standard WHO antituberculosis therapy was applied; thus, the result may be different from the current application. Conclusion: Currently, there was no guideline on pulmonary resection. However, surgery yielded better mortality and morbidity in children with complicated pulmonary TB.

Keywords: pediatric, pulmonary, surgery, therapy, tuberculosis

Procedia PDF Downloads 83
347 Combined Tarsal Coalition Resection and Arthroereisis in Treatment of Symptomatic Rigid Flat Foot in Pediatric Population

Authors: Michael Zaidman, Naum Simanovsky

Abstract:

Introduction. Symptomatic tarsal coalition with rigid flat foot often demands operative solution. An isolated coalition resection does not guarantee pain relief; correction of co-existing foot deformity may be required. The objective of the study was to analyze the results of combination of tarsal coalition resection and arthroereisis. Patients and methods. We retrospectively reviewed medical records and radiographs of children operatively treated in our institution for symptomatic calcaneonavicular or talocalcaneal coalition between the years 2019 and 2022. Eight patients (twelve feet), 4 boys and 4 girls with mean age 11.2 years, were included in the study. In six patients (10 feet) calcaneonavicular coalition was diagnosed, two patients (two feet) sustained talonavicular coalition. To quantify degrees of foot deformity, we used calcaneal pitch angle, lateral talar-first metatarsal (Meary's) angle, and talonavicular coverage angle. The clinical results were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Score. Results. The mean follow-up was 28 month. The preoperative mean talonavicular coverage angle was 17,75º as compared with postoperative mean angle of 5.4º. The calcaneal pitch angle improved from mean 6,8º to 16,4º. The mean preoperative Meary’s angle of -11.3º improved to mean 2.8º. The preoperative mean AOFAS score improved from 54.7 to 93.1 points post-operatively. In nine of twelve feet, overall clinical outcome judged by AOFAS scale was excellent (90-100 points), in three feet was good (80-90 points). Six patients (ten feet) obviously improved their subtalar range of motion. Conclusion. For symptomatic stiff or rigid flat feet associated with tarsal coalition, the combination of coalition resection and arthroereisis leads to normalization of radiographic parameters, clinical and functional improvement with good patient’s satisfaction and likely to be more effective than the isolated procedures.

Keywords: rigid flat foot, tarsal coalition resection, arthroereisis, outcome

Procedia PDF Downloads 35
346 Modeling and Control of a 4DoF Robotic Assistive Device for Hand Rehabilitation

Authors: Christopher Spiewak, M. R. Islam, Mohammad Arifur Rahaman, Mohammad H. Rahman, Roger Smith, Maarouf Saad

Abstract:

For those who have lost the ability to move their hand, going through repetitious motions with the assistance of a therapist is the main method of recovery. We have been developed a robotic assistive device to rehabilitate the hand motions in place of the traditional therapy. The developed assistive device (RAD-HR) is comprised of four degrees of freedom enabling basic movements, hand function, and assists in supporting the hand during rehabilitation. We used a nonlinear computed torque control technique to control the RAD-HR. The accuracy of the controller was evaluated in simulations (MATLAB/Simulink environment). To see the robustness of the controller external disturbance as modelling uncertainty (±10% of joint torques) were added in each joints.

Keywords: biorobotics, rehabilitation, robotic assistive device, exoskeleton, nonlinear control

Procedia PDF Downloads 440
345 Local and Systemic Complications after Resection of Rectal Cancer in the Department of General and Abdominal Surgery University Clinical Center Maribor between 2004 and 2014

Authors: Nuhi Arslani, Stojan Potrc, Timotej Mikuljan

Abstract:

Background: In Department of Abdominal and General Surgery of University Medical Centre Maribor, we treated 578 patients for rectal cancer between 2004 and 2014. During and after treatment we especially concentrated on monitoring local and systemic complications. Methods: For analysis, we used data gathered from preoperative diagnostic tests, reports gathered during operation, reports from the pathohistologic review, and reports on complications after surgery and follow up. Results: In the case of 573 (out of 578) patients (99.1%) we performed resection. R0 was achieved in 551 patients (96,1%). R1 was achieved in 8 patients (1,4%). R2 was achieved in 14 patients (2,4%). Local complications were reported in 78 (13.5%) patients and systemic complications were reported in 68 (11.7%). We would like to point out the low number of local and systemic complications. Conclusions: With advances in surgical techniques, with a multimodal-multidisciplinary approach and with the use of total mesorectal excision we experienced a significant improvement in reducing the number of local and systemic complications in patients with rectal cancer. However, there still remains the question for truly optimal care for each patient with rectal cancer and his quality of life after surgical treatment.

Keywords: local complications, rectal cancer, resection, systemic complications

Procedia PDF Downloads 134
344 The Applications of Wire Print in Composite Material Research and Fabrication Process

Authors: Hsu Yi-Chia, Hoy June-Hao

Abstract:

FDM (Fused Deposition Modeling) is a rapid proofing method without mold, however, high material and time costs have always been a major disadvantage. Wire-printing is the next generation technology that can more flexible, and also easier to apply on a 3D printer and robotic arms printing. It can create its own construction methods. The research is mainly divided into three parts. The first is about the method of parameterizing the generated paths and the conversion of g-code to the wire-printing. The second is about material attempts and the application of effects. Third, is about the improvement of the operation of mechanical equipment and the design of robotic tool-head. The purpose of this study is to develop a new wire-print method that can efficiently generate line segments and paths in three- dimensions space. The parametric modeling software transforms the digital model into a 3D printer or robotic arms g-code, this article uses thermoplastics/ clay/composites materials for testing. The combination of materials and wire-print process makes architects and designers have the ability to research and develop works and construction in the future.

Keywords: parametric software, wire print, robotic arms fabrication, composite filament additive manufacturing

Procedia PDF Downloads 105
343 Multidisciplinary Rehabilitation Algorithm after Mandibular Resection for Ameloblastoma

Authors: Joaquim de Almeida Dultra, Daiana Cristina Pereira Santana, Fátima Karoline Alves Araújo Dultra, Liliane Akemi Kawano Shibasaki, Mariana Machado Mendes de Carvalho, Ieda Margarida Crusoé Rocha Rebello

Abstract:

Defects originating from mandibular resections can cause significant functional impairment and facial disharmony, and they have complex rehabilitation. The aim of this report is to demonstrate the authors' experience facing challenging rehabilitation after mandibular resection in a patient with ameloblastoma. Clinical and surgical steps are described simultaneously, highlighting the adaptation of the final fixed prosthesis, reported in an unprecedented way in the literature. A 37-year-old male patient was seen after a sports accident, where a pathological fracture in the symphysis and left mandibular body was identified, where a large radiolucent lesion was found. The patient underwent resection, bone graft, distraction osteogenesis, rehabilitation with dental implants, prosthesis, and finally, orofacial harmonization, in an interval of six years. Rehabilitation should consider the patient's needs individually and should have as the main objective to provide similar aesthetics and function to that present before the disease. We also emphasize the importance of interdisciplinary work during the course of rehabilitation.

Keywords: ameloblastoma, mandibular reconstruction, distraction osteogenesis, dental implants. dental prosthesis, implant-supported, treatment outcome

Procedia PDF Downloads 77
342 Effect of Robot Configuration Parameters, Masses and Friction on Painlevé Paradox for a Sliding Two-Link (P-R) Robot

Authors: Hassan Mohammad Alkomy, Hesham Elkaranshawy, Ahmed Ibrahim Ashour, Khaled Tawfik Mohamed

Abstract:

For a rigid body sliding on a rough surface, a range of uncertainty or non-uniqueness of solution could be found, which is termed: Painlevé paradox. Painlevé paradox is the reason of a wide range of bouncing motion, observed during sliding of robotic manipulators on rough surfaces. In this research work, the existence of the paradox zone during the sliding motion of a two-link (P-R) robotic manipulator with a unilateral constraint is investigated. Parametric study is performed to investigate the effect of friction, link-length ratio, total height and link-mass ratio on the paradox zone.

Keywords: dynamical system, friction, multibody system, painlevé paradox, robotic systems, sliding robots, unilateral constraint

Procedia PDF Downloads 426
341 Endometrial Ablation and Resection Versus Hysterectomy for Heavy Menstrual Bleeding: A Systematic Review and Meta-Analysis of Effectiveness and Complications

Authors: Iliana Georganta, Clare Deehan, Marysia Thomson, Miriam McDonald, Kerrie McNulty, Anna Strachan, Elizabeth Anderson, Alyaa Mostafa

Abstract:

Context: A meta-analysis of randomized controlled trials (RCTs) comparing hysterectomy versus endometrial ablation and resection in the management of heavy menstrual bleeding. Objective: To evaluate the clinical efficacy, satisfaction rates and adverse events of hysterectomy compared to more minimally invasive techniques in the treatment of HMB. Evidence Acquisition: A literature search was performed for all RCTs and quasi-RCTs comparing hysterectomy with either endometrial ablation endometrial resection of both. The search had no language restrictions and was last updated in June 2020 using MEDLINE, EMBASE, Cochrane Central Register of Clinical Trials, PubMed, Google Scholar, PsycINFO, Clinicaltrials.gov and Clinical trials. EU. In addition, a manual search of the abstract databases of the European Haemophilia Conference on women's health was performed and further studies were identified from references of acquired papers. The primary outcomes were patient-reported and objective reduction in heavy menstrual bleeding up to 2 years and after 2 years. Secondary outcomes included satisfaction rates, pain, adverse events short and long term, quality of life and sexual function, further surgery, duration of surgery and hospital stay and time to return to work and normal activities. Data were analysed using RevMan software. Evidence synthesis: 12 studies and a total of 2028 women were included (hysterectomy: n = 977 women vs endometrial ablation or resection: n = 1051 women). Hysterectomy was compared with endometrial ablation only in five studies (Lin, Dickersin, Sesti, Jain, Cooper) and endometrial resection only in five studies (Gannon, Schulpher, O’Connor, Crosignani, Zupi) and a mixture of the Ablation and Resection in two studies (Elmantwe, Pinion). Of the 1² studies, 10 reported women’s perception of bleeding symptoms as improved. Meta-analysis showed that women in the hysterectomy group were more likely to show improvement in bleeding symptoms when compared with endometrial ablation or resection up to 2-year follow-up (RR 0.75, 95% CI 0.71 to 0.79, I² = 95%). Objective outcomes of improvement in bleeding also favored hysterectomy. Patient satisfaction was higher after hysterectomy within the 2 years follow-up (RR: 0.90, 95%CI: 0.86 to 0.94, I²:58%), however, there was no significant difference between the two groups at more than 2 years follow up. Sepsis (RR: 0.03, 95% CI 0.002 to 0.56; 1 study), wound infection (RR: 0.05, 95% CI: 0.01 to 0.28, I²: 0%, 3 studies) and Urinary tract infection (UTI) (RR: 0.20, 95% CI: 0.10 to 0.42, I²: 0%, 4 studies) all favoured hysteroscopic techniques. Fluid overload (RR: 7.80, 95% CI: 2.16 to 28.16, I² :0%, 4 studies) and perforation (RR: 5.42, 95% CI: 1.25 to 23.45, I²: 0%, 4 studies) however favoured hysterectomy in the short term. Conclusions: This meta-analysis has demonstrated that endometrial ablation and endometrial resection are both viable options when compared with hysterectomy for the treatment of heavy menstrual bleeding. Hysteroscopic procedures had better outcomes in the short term with fewer adverse events including wound infection, UTI and sepsis. The hysterectomy performed better when measuring more long-term impacts such as recurrence of symptoms, overall satisfaction at two years and the need for further treatment or surgery.

Keywords: menorrhagia, hysterectomy, ablation, resection

Procedia PDF Downloads 129
340 An Inherent Risk to Damage the Popliteus Tendon by Some Femoral Component Designs: A Pilot Study in Indian Knees

Authors: Rajendra Kanojia

Abstract:

Femoral components with inbuilt rotation require thicker flexion resection of the lateral femoral condyle and could potential risk to damage the popliteus tendon especially in the smaller Asian knees. We prospectively evaluated 10 patients with bilateral varus osteoarthritis knee to size the cuts and their location in relation to the popliteus tendon. Two different types of implant were used on either side, one side requires resection in 3° external rotation (group A) and other side femoral component with inbuilt external roation (group B). We had popliteus tendon injury in 3 knees all from group B. Risk of damaging the popliteus tendon was found higher in group B.

Keywords: popliteaus tendon injury, TKA, orthopaedic surgery, biomechanics and clinical applications

Procedia PDF Downloads 305
339 Comparison of Stereotactic Craniotomy for Brain Metastasis, as Compared to Stereotactic Radiosurgery

Authors: Mostafa El Khashab

Abstract:

Our experience with 50 patients with metastatic tumors located in different locations of the brain by a stereotactic-guided craniotomy and total microsurgical resection. Patients ranged in age from 36 to 73 years. There were 28 women and 22 men. Thirty-four patients presented with hemiparesis and 6 with aphasia and the remaining presented with psychological manifestations and memory issues. Gross total resection was accomplished in all cases, with postoperative imaging confirmation of complete removal. Forty patients were subjected to whole brain irradiation. One patient developed a stroke postoperatively and another one had a flap infection. 4 patients developed different postoperative but unrelated morbidities, including pneumonia and DVT. No mortality was encountered. We believe that with the assistance of stereotactic localization, metastases in vital regions of the brain can be removed with very low neurologic morbidity and that, in comparison to other modalities, they fare better regarding their long-term outcome.

Keywords: stereotactic, craniotomy, radiosurgery, patient

Procedia PDF Downloads 54
338 Low-Cost Robotic-Assisted Laparoscope

Authors: Ege Can Onal, Enver Ersen, Meltem Elitas

Abstract:

Laparoscopy is a surgical operation, well known as keyhole surgery. The operation is performed through small holes, hence, scars of a patient become much smaller, patients can recover in a short time and the hospital stay becomes shorter in comparison to an open surgery. Several tools are used at laparoscopic operations; among them, the laparoscope has a crucial role. It provides the vision during the operation, which will be the main focus in here. Since the operation area is very small, motion of the surgical tools might be limited in laparoscopic operations compared to traditional surgeries. To overcome this limitation, most of the laparoscopic tools have become more precise, dexterous, multi-functional or automated. Here, we present a robotic-assisted laparoscope that is controlled with pedals directly by a surgeon. Thus, the movement of the laparoscope might be controlled better, so there will not be a need to calibrate the camera during the operation. The need for an assistant that controls the movement of the laparoscope will be eliminated. The duration of the laparoscopic operation might be shorter since the surgeon will directly operate the camera.

Keywords: laparoscope, laparoscopy, low-cost, minimally invasive surgery, robotic-assisted surgery

Procedia PDF Downloads 315
337 Electromyography Controlled Robotic Toys for Autistic Children

Authors: Uvais Qidwai, Mohamed Shakir

Abstract:

This paper presents an initial study related to the use of robotic toys as teaching and therapeutic aid tools for teachers and care-givers as well as parents of children with various levels of autism spectrum disorder (ASD). Some of the most common features related to the behavior of a child with ASD are his/her social isolation, living in their own world, not being physically active, and not willing to learn new things. While the teachers, parents, and all other related care-givers do their best to improve the condition of these kids, it is usually quite an uphill task. However, one remarkable observation that has been reported by several teachers dealing with ASD children is the fact that the same children do get attracted to toys with lights and sounds. Hence, this project targets the development/modifications of such existing toys into appropriate behavior training tools which the care-givers can use as they would desire. Initially, the remote control is in hand of the trainer, but after some time, the child is entrusted with the control of the robotic toy to test for the level of interest. It has been found during the course of this study that children with quite low learning activity got extremely interested in the robot and even advanced to controlling the robot with the Electromyography (EMG). It has been observed that the children did show some hesitation in the beginning 5 minutes of the very first sessions of such interaction but were very comfortable afterwards which has been considered as a very strong indicator of the potential of this technique in teaching and rehabilitation of children with ASD or similar brain disorders.

Keywords: Autism Spectrum Disorder (ASD), robotic toys, IR control, electromyography, LabVIEW based remote control

Procedia PDF Downloads 415
336 Assessing Mobile Robotic Telepresence Based On Measures of Social Telepresence

Authors: A. Bagherzadhalimi, E. Di Maria

Abstract:

The feedbacks obtained regarding the sense of presence from pilot users operating a Mobile Robotic presence (MRP) system to visit a simulated museum are reported in this paper. The aim is to investigate how much the perception of system’s usefulness and ease of use is affected by operators’ sense of social telepresence (presence) in the remote location. Therefore, scenarios of visiting a museum are simulated and the user operators are supposed to perform some regular tasks inside the remote environment including interaction with local users, navigation and visiting the artworks. Participants were divided into two groups, those who had previous experience of operation and interaction with a MRP system and those who never had experience. Based on the results, both groups provided different feedbacks. Moreover, there was a significant association between user’s sense of presence and their perception of system usefulness and ease of use.

Keywords: mobile robotic telepresence, museum, social telepresence, usability test

Procedia PDF Downloads 368
335 Reliability Analysis for the Functioning of Complete and Low Capacity MLDB Systems in Piston Plants

Authors: Ramanpreet Kaur, Upasana Sharma

Abstract:

The purpose of this paper is to address the challenges facing the water supply for the Machine Learning Database (MLDB) system at the piston foundry plant. In the MLDB system, one main unit, i.e., robotic, is connected by two sub-units. The functioning of the system depends on the robotic and water supply. Lack of water supply causes system failure. The system operates at full capacity with the help of two sub-units. If one sub-unit fails, the system runs at a low capacity. Reliability modeling is performed using semi-Markov processes and regenerative point techniques. Several system effects such as mean time to system failure, availability at full capacity, availability at reduced capacity, busy period for repair and expected number of visits have been achieved. Benefits have been analyzed. The graphical study is designed for a specific case using programming in C++ and MS Excel.

Keywords: MLDB system, robotic, semi-Markov process, regenerative point technique

Procedia PDF Downloads 79
334 Combine Resection of Talocalcaneal Tarsal Coalition and Calcaneal Lengthening Osteotomy. Short-to-Intermediate Term Results

Authors: Naum Simanovsky, Vladimir Goldman, Michael Zaidman

Abstract:

Background: The optimal algorithm for the management of symptomatic tarsal coalition is still under discussion in pediatric literature. It's debatable what surgical steps are essential to achieve the best outcome. Method: The investigators retrospectively reviewed the records of twelve patients with symptomatic tarsal coalition that were treated operatively between 2017 and 2019. Only painful flat feet were operated. Two patients were excluded from the study due to lack of sufficient follow-up. Ten of eleven feet were treated with the combination of calcaneal lengthening osteotomy (CLO) and resection of coalition (RC). Only one foot was operated with CLO alone. In half of our patients, Achilles lengthening was performed. For two children, medial plication was added. Short leg cast was applied to all children for 6-8 weeks, and soft shoe insoles for medial arch support were prescribed after. Demographic, clinical, and radiographic records were reviewed. The outcome was evaluated using American Orthopedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Score. Results: There were seven boys and three girls. The mean age at the time of surgery was 13.9 (range 12 to 17) years, and the mean follow-up was 18 (range 8 to 34) months. The early complications included one superficial wound infection and dehiscence. Late complication includes two children with residual forefoot supination. None of our patients required additional operations during the follow-up period. All feet achieved complete deformity correction or dramatic improvement. In the last follow-up, seven feet were painless, and four children had some mild pain after intensive activities. All feet achieved excellent and good scoring on AOFAS. Conclusions: Many patients with talocalcaneal coalition also have rigid or stiff, painful, flat feet. For these patients, the resection of coalition with concomitant CLO can be safely recommended.

Keywords: Tarsal coalition, calcaneal lengthening osteotomy., flat foot, coalition resection

Procedia PDF Downloads 36
333 Metal Ship and Robotic Car: A Hands-On Activity to Develop Scientific and Engineering Skills for High School Students

Authors: Jutharat Sunprasert, Ekapong Hirunsirisawat, Narongrit Waraporn, Somporn Peansukmanee

Abstract:

Metal Ship and Robotic Car is one of the hands-on activities in the course, the Fundamental of Engineering that can be divided into three parts. The first part, the metal ships, was made by using engineering drawings, physics and mathematics knowledge. The second part is where the students learned how to construct a robotic car and control it using computer programming. In the last part, the students had to combine the workings of these two objects in the final testing. This aim of study was to investigate the effectiveness of hands-on activity by integrating Science, Technology, Engineering and Mathematics (STEM) concepts to develop scientific and engineering skills. The results showed that the majority of students felt this hands-on activity lead to an increased confidence level in the integration of STEM. Moreover, 48% of all students engaged well with the STEM concepts. Students could obtain the knowledge of STEM through hands-on activities with the topics science and mathematics, engineering drawing, engineering workshop and computer programming; most students agree and strongly agree with this learning process. This indicated that the hands-on activity: “Metal Ship and Robotic Car” is a useful tool to integrate each aspect of STEM. Furthermore, hands-on activities positively influence a student’s interest which leads to increased learning achievement and also in developing scientific and engineering skills.

Keywords: hands-on activity, STEM education, computer programming, metal work

Procedia PDF Downloads 436
332 Robotic Arm Allowing a Diabetic Quadriplegic Patient to Self-Administer Insulin

Authors: L. Parisi

Abstract:

A method which allows a diabetic quadriplegic patient that has had four limb amputations (above the knee and elbow) to self-administer injections of insulin has been designed. The aim of this research project is to improve a quadriplegic patient’s self-management, affected by diabetes, by designing a suitable device for self-administering insulin.The quadriplegic patient affected by diabetes has to be able to self-administer insulin safely and independently to guarantee stable healthy conditions. The device also should be designed to adapt to a number of different varying personal characteristics such as height and body weight.

Keywords: robotic arm, self-administration, insulin, diabetes, quadriplegia

Procedia PDF Downloads 334