Search results for: morphine detection
3488 Detection of Heroin and Its Metabolites in Urine Samples: A Chemiluminescence Approach
Authors: Sonu Gandhi, Neena Capalash, Prince Sharma, C. Raman Suri
Abstract:
A sensitive chemiluminescence immunoassay (CIA) for heroin and its major metabolites is reported. The method is based on the competitive reaction of horseradish peroxidase (HRP)-labeled anti-MAM antibody and free drug in spiked urine samples. A hapten-protein conjugate was synthesized by using acidic derivative of monoacetyl morphine (MAM) coupled to carrier protein BSA and was used as an immunogen for the generation of anti-MAM (monoacetyl morphine) antibody. A high titer of antibody (1:64,0000) was obtained and the relative affinity constant (Kaff) of antibody was 3.1×107 l/mol. Under the optimal conditions, linear range and reactivity for heroin, mono acetyl morphine (MAM), morphine and codeine were 0.08, 0.09, 0.095 and 0.092 ng/mL respectively. The developed chemiluminescence inhibition assay could detect heroin and its metabolites in standard and urine samples up to 0.01 ng/ml.Keywords: heroin, metabolites, chemiluminescence immunoassay, horse radish peroxidase
Procedia PDF Downloads 2703487 Fabrication of a New Electrochemical Sensor Based on New Nanostructured Molecularly Imprinted Polypyrrole for Selective and Sensitive Determination of Morphine
Authors: Samaneh Nabavi, Hadi Shirzad, Arash Ghoorchian, Maryam Shanesaz, Reza Naderi
Abstract:
Morphine (MO), the most effective painkiller, is considered the reference by which analgesics are assessed. It is very necessary for the biomedical applications to detect and maintain the MO concentrations in the blood and urine with in safe ranges. To date, there are many expensive techniques for detecting MO. Recently, many electrochemical sensors for direct determination of MO were constructed. The molecularly imprinted polymer (MIP) is a polymeric material, which has a built-in functionality for the recognition of a particular chemical substance with its complementary cavity.This paper reports a sensor for MO using a combination of a molecularly imprinted polymer (MIP) and differential-pulse voltammetry (DPV). Electropolymerization of MO doped polypyrrole yielded poor quality, but a well-doped, nanostructure and increased impregnation has been obtained in the pH=12. Above a pH of 11, MO is in the anionic forms. The effect of various experimental parameters including pH, scan rate and accumulation time on the voltammetric response of MO was investigated. At the optimum conditions, the concentration of MO was determined using DPV in a linear range of 7.07 × 10−6 to 2.1 × 10−4 mol L−1 with a correlation coefficient of 0.999, and a detection limit of 13.3 × 10-8 mol L−1, respectively. The effect of common interferences on the current response of MO namely ascorbic acid (AA) and uric acid (UA) is studied. The modified electrode can be used for the determination of MO spiked into urine samples, and excellent recovery results were obtained. The nanostructured polypyrrole films were characterized by field emission scanning electron microscopy (FESEM) and furrier transforms infrared (FTIR).Keywords: morphine detection, sensor, polypyrrole, nanostructure, molecularly imprinted polymer
Procedia PDF Downloads 4233486 Heroin and Opiates Metabolites Tracing by Gas-Chromatography Isotope Ratio Mass Spectrometry
Authors: Yao-Te Yen, Chao-Hsin Cheng, Meng-Shun Huang, Shan-Zong Cyue
Abstract:
'Poppy-seed defense' has been a serious problem all over the world, that is because the opiates metabolites in urine are difficult to distinguish where they come from precisely. In this research, a powerful analytic method has been developed to trace the opiates metabolites in urine by Gas-Chromatography Isotope Ratio Mass Spectrometry (GC-IRMS). In order to eliminate the interference of synthesis to heroin or metabolism through human body, opiates metabolites in urine and sized heroin were hydrolyzed to morphine. Morphine is the key compound for tracing between opiates metabolites and seized heroin in this research. By matching δ13C and δ15N values through morphine, it is successful to distinguish the opiates metabolites coming from heroin or medicine. We tested seven heroin abuser’s metabolites and seized heroin in crime sites, the result showed that opiates metabolites coming from seized heroin, the variation of δ13C and δ15N for morphine are within 0.2 and 2.5‰, respectively. The variation of δ13C and δ15N for morphine are reasonable with the result of matrix match experiments. Above all, the uncertainty of 'Poppy-seed defense' can be solved easily by this analytic method, it provides the direct evidence for judge to make accurate conviction without hesitation.Keywords: poppy-seed defense, heroin, opiates metabolites, isotope ratio mass spectrometry
Procedia PDF Downloads 2393485 A Comparative Study of Morphine and Clonidine as an Adjunct to Ropivacaine in Paravertebral Block for Modified Radical Mastectomy
Authors: Mukesh K., Siddiqui A. K., Abbas H., Gupta R.
Abstract:
Background: General Anesthesia is a standard for breast onco-surgery. The issue of postoperative pain and the occurrence of nausea and vomiting has prompted the quest for a superior methodology with fewer complications. Over the recent couple of years, paravertebral block (PVB) has acquired huge fame either in combination with GA or alone for anesthetic management. In this study, we aim to evaluate the efficacy of morphine and clonidine as an adjunct to ropivacaine in a paravertebral block in breast cancer patients undergoing modified radical mastectomy. Methods: In this study, total 90 patients were divided into three groups (30 each) on the basis of computer-generated randomization. Group C (Control): Paravertebral block with 0.25% ropivacaine (19ml) and 1 ml saline; Group M- Paravertebral block with 0.25% ropivacaine(19ml) + 20 microgram/kg body weight morphine; Group N: Paravertebral block with 0.25% ropivacaine(19ml) +1.0 microgram/kg body weight clonidine. The postoperative pain intensity was recorded using the visual analog scale (VAS) and Sedation was observed by the Ramsay Sedation score (RSS). Results: The VAS was similar at 0hr, 2hr and 4 hr in the postoperative period among all the groups. There was a significant (p=0.003) difference in VAS from 6 hr to 20 hr in the postoperative period among the groups. A significant (p<0.05) difference was observed among the groups at 8 hr to 20 hr). The first requirement of analgesia was significantly (p=0.001) higher in Group N (7.70±1.74) than in Group C (4.43±1.43) and Group M (7.33±2.21). Conclusion: The morphine in the paravertebral block provides better postoperative analgesia. The consumption of rescue analgesia was significantly reduced in the morphine group as compared to the clonidine group. The procedure also proved to be safe as no complication was encountered in the paravertebral block in our study.Keywords: ropivacaine, morphine, clonidine, paravertebral block
Procedia PDF Downloads 1173484 Production of Camel Nanobodies against of Anti-Morphine-3-Glucuronide for the Development of a Biosensor for Detecting Illicit Drug
Authors: Shirin Jalili, Sadegh Hasannia, Hadi Shirzad, Afshin Khara
Abstract:
Morphine is one of the most medicinally important analgesics and narcotics. Structurally, it is classified as an alkaloid because of the presence of nitrogen. Its structure is similar to that of codeine, thebaine, and heroin. An immunoassay to accurately discriminate between these analogous alkaloids would be highly beneficial. A key factor for such an assay is specificity with high sensitivity, which is totally dependent on the antibody employed. However, most antibodies against haptens are polyclonal serum antibodies that exhibit significant cross-reactivities with closely related compounds. The camel-derived single-chain antibody fragments (VHH) are the smallest molecules with antigen-binding capacity, possessing unique properties compared to other conventional antibodies. In this study, a library containing the VHH genes of a camel immunized with with morphine conjugated BSA following phage display technology was generated. By screening the camel-derived variable region of the heavy chain cDNA phage display library with the ability to bind the desired hapten, we obtained some nanobodies that recognize this hapten. Phage display expression of the Nbs from this library and pannings against this hapten resulted in a clear enrichment of four distinct Nb-displaying phages with specificity for morphine that could be a potential target site for the development of new strategies for the development of a biosensor for detecting illicit drug.Keywords: phage display, nanobody, Morphine-3, glucuronide, ELISA, biosensor
Procedia PDF Downloads 4253483 Comparison of the Postoperative Analgesic Effects of Morphine, Paracetamol, and Ketorolac in Patient-Controlled Analgesia in the Patients Undergoing Open Cholecystectomy
Authors: Siamak Yaghoubi, Vahideh Rashtchi, Marzieh Khezri, Hamid Kayalha, Monadi Hamidfar
Abstract:
Background and objectives: Effective postoperative pain management in abdominal surgeries, which are painful procedures, plays an important role in reducing postoperative complications and increasing patient’s satisfaction. There are many techniques for pain control, one of which is Patient-Controlled Analgesia (PCA). The aim of this study was to compare the analgesic effects of morphine, paracetamol and ketorolac in the patients undergoing open cholecystectomy, using PCA method. Material and Methods: This randomized controlled trial was performed on 330 ASA (American Society of Anesthesiology) I-II patients ( three equal groups, n=110) who were scheduled for elective open cholecystectomy in Shahid Rjaee hospital of Qazvin, Iran from August 2013 until September 2015. All patients were managed by general anesthesia with TIVA (Total Intra Venous Anesthesia) technique. The control group received morphine with maximum dose of 0.02mg/kg/h, the paracetamol group received paracetamol with maximum dose of 1mg/kg/h, and the ketorolac group received ketorolac with maximum daily dose of 60mg using IV-PCA method. The parameters of pain, nausea, hemodynamic variables (BP and HR), pruritus, arterial oxygen desaturation, patient’s satisfaction and pain score were measured every two hours for 8 hours following operation in all groups. Results: There were no significant differences in demographic data between the three groups. there was a statistically significant difference with regard to the mean pain score at all times between morphine and paracetamol, morphine and ketorolac, and paracetamol and ketorolac groups (P<0.001). Results indicated a reduction with time in the mean level of postoperative pain in all three groups. At all times the mean level of pain in ketorolac group was less than that in the other two groups (p<0.001). Conclusion: According to the results of this study ketorolac is more effective than morphine and paracetamol in postoperative pain control in the patients undergoing open cholecystectomy, using PCA method.Keywords: analgesia, cholecystectomy, ketorolac, morphine, paracetamol
Procedia PDF Downloads 1973482 The Role of Glyceryl Trinitrate (GTN) in 99mTc-HIDA with Morphine Provocation Scan for the Investigation of Type III Sphincter of Oddi Dysfunction (SOD)
Authors: Ibrahim M Hassan, Lorna Que, Michael Rutland
Abstract:
Type I SOD is usually diagnosed by anatomical imaging such as ultrasound, CT and MRCP. However, the types II and III SOD yield negative results despite the presence of significant symptoms. In particular, the type III is difficult to diagnose due to the absence of significant biochemical or anatomical abnormalities. Nuclear Medicine can aid in this diagnostic dilemma by demonstrating functional changes in the bile flow. Low dose Morphine (0.04mg/Kg) stimulates the tone of the sphincter of Oddi (SO) and its usefulness has been shown in diagnosing SOD by causing a delay in bile flow when compared to a non morphine provoked - baseline scan. This work expands on that process by using sublingual GTN at 60 minutes post tracer and morphine injection to relax the SO and induce an improvement in bile outflow, and in some cases show immediate relief of morphine induced abdominal pain. The criteria for positive SOD are as follows: if during the first hour of the morphine provocation showed (1) delayed intrahepatic biliary ducts tracer accumulation; plus (2) delayed appearance but persistent retention of activity in the common bile duct, and (3) delayed bile flow into the duodenum. In addition, patients who required GTN within the first hour to relieve abdominal pain were regarded as highly supportive of the diagnosis. Retrospective analysis of 85 patients (pts) (78F and 6M) referred for suspected SOD (type III) who had been intensively investigated because of recurrent right upper quadrant or abdominal pain post cholecystectomy. 99mTc-HIDA scan with morphine-provocation is performed followed by GTN at 60 minutes post tracer injection and a further thirty minutes of dynamic imaging are acquired. 30 pts were negative. 55 pts were regarded as positive for SOD and 38/55 (60%) of these patients with an abnormal result were further evaluated with a baseline 99mTc-HIDA. As expected, all 38 pts showed better bile flow characteristics than during the morphine provocation. 20/55 (36%) patients were treated by ERCP sphincterotomy and the rest were managed conservatively by medical therapy. In all cases regarded as positive for SOD, the sublingual GTN at 60 minutes showed immediate improvement in bile flow. 11/55(20%) who developed severe post-morphine abdominal pain were relieved by GTN almost instantaneously. We propose that GTN is a useful agent in the diagnosis of SOD when performing 99mTc-HIDA scan and that the satisfactory response to the sublingual GTN could offer additional information in patients who have severe pain at the time the procedure or when presenting to the emergency unit because of biliary pain. And also in determining whether a trial of medical therapy may be used before considering surgery.Keywords: GTN, HIDA, MORPHINE, SOD
Procedia PDF Downloads 3043481 Analgesic Efficacy of Opiorphin and Its Analogue
Authors: Preet Singh, Kavitha Kongara, Dave Harding, Neil Ward, Paul Chambers
Abstract:
The objective of this study was to compare the analgesic efficacy of opiorphin and its analogue with a mu-receptor agonist; morphine. Opiorphins (Gln-Arg-Phe-Ser-Arg) belong to the family of endogenous enkephalinase inhibitors, found in saliva of humans. They are inhibitors of two Zinc metal ectopeptidases (Neutral endopeptidase NEP, and amino-peptidase APN) which are responsible for the inactivation of the endogenous opioids; endorphins and enkephalins. Morphine and butorphanol exerts their analgesic effects by mimicking the actions of endorphins and enkephalins. The opiorphin analogue was synthesized based on the structure activity relationship of the amino acid sequence of opiorphin. The pharmacological profile of the analogue was tested by replacing Serine at position 4 with Proline. The hot plate and tail flick test were used to demonstrate the analgesic efficacy. There was a significant increase in the time for the tail flick response after an injection of opiorphin, which was similar to the morphine effect. There was no increase in time in the hot plate test after an injection of opiorphin. The results suggest that opiorphin works at spinal level only rather than both spinal and supraspinal. Further work is required to confirm our results. We did not find analgesic activity of the opiorphin analogue. Thus, Serine at position 4 is also important for its pharmacological action. Further work is required to illustrate the role of serine at position 4 in opiorphin.Keywords: analgesic peptides, endogenous opioids, morphine, opiorphin
Procedia PDF Downloads 3253480 Real World Cancer Pain Incidence and Treatment in Daily Hospital
Authors: Alexandru Grigorescu, Alexandra Protesanu
Abstract:
Background: Approximately 34-67 percent of cancer patients experience an episode of uncontrolled pain during the course of their disease, depending on the stage. The aim is to provide evidence-based data for pain prevalence, diagnosis and treatment recommendations on an integrative model of medical oncology and palliative care for patients with cancer diagnostic in a day hospital. Patients and method: Consultation registers and electronic records of 166 Patients (Pts) were studied from April 2022 to March 2023. Pts with pain syndrome were selected. The pain was objectified by the visual pain scale. To elucidate the causes of the pain, investigations were carried out: bone scintigraphy, CT scan, and PET-CT. The analgesic treatments were represented by weak and strong morphine, radiotherapy, and bisphosphonates. Result: During the mentioned period, 166 oncological patients (74 women and 92 men) were treated in the oncology day hospitalization service. There were 1,500 consultations, 40 of which were only for pain. The neoplastic locations were: gynecological, malignant melanoma, breast, gastric, bronchopulmonary, colorectal, liver, pancreatic, bladder, and kidney. 70 Pts presented pain syndrome. The causes of the pain were represented by bone metastases, compressive tumors, and post-surgical status. Drug treatment: Tramadol 47 Pts, of which 10 switched to a major opioid (Oxycodonum, Morphine sulfate), 20 Pts were treated with Oxycodonum as the first intention. In 5 patients ry to rotated morphine, 20 Pts received palliative radiotherapy, 10 Pts were treated with bisphosphonates. 2 Pts required neurosurgery consultation for an antalgic intervention. 5 Pts had important adverse reactions to morphine. All patients and their families were advised by a medical oncologist and psychologist for a lifestyle change. Conclusions: The prevalence of pain was similar to that described in the literature. In most cases, the pain could be managed in the day hospital. Weak and strong morphine represented the main pain therapy. Palliative radiotherapy was the second most effective therapy. Treatment with bisphosphonates was useful. Surgical interventions were rarely indicated. Discussions with patients and their families regarding the lifestyle change were important.Keywords: cancer pain, opioids, medical oncology, palliative care
Procedia PDF Downloads 653479 The Analgesic Impact of Adding Intrathecal Ketamine to Spinal Anaesthesia for Hip or Knee Arthroplasty: A Clinical Audit
Authors: Carl Ashworth, Matthys Campher
Abstract:
Spinal anaesthesia has been identified as the “gold standard” for primary elective total hip and knee arthroplasty, which is most commonly performed using longer-acting local anaesthetics, such as hyperbaric bupivacaine, to prolong the duration of anaesthesia and analgesia suitable for these procedures. Ketamine is known to have local anaesthetic effects with potent analgesic properties and has been evaluated as a sole anaesthetic agent via intrathecal administration; however, the use of intrathecal ketamine as an adjunct to intrathecal hyperbaric bupivacaine, morphine, and fentanyl has not been extensively studied. The objective of this study was to identify the potential analgesic effects of the addition of intrathecal ketamine to spinal anaesthesia and to compare the efficacy and safety of adding intrathecal ketamine to spinal anaesthesia for hip- or knee arthroplasty with spinal anaesthesia for hip- or knee arthroplasty without intrathecal ketamine. The medical records of patients who underwent elective hip- or knee arthroplasty under spinal anaesthesia performed by an individual anaesthetist with either intrathecal hyperbaric bupivacaine, morphine and fentanyl or intrathecal hyperbaric bupivacaine, morphine, fentanyl and ketamine between June 4, 2020, and June 4, 2022, were retrospectively reviewed. These encounters were reviewed and analyzed from a perioperative pain perspective, with the primary outcome measure as the oral morphine equivalent (OME) usage in the 48 hours post-spinal anaesthesia, and secondary outcome measures including time to breakthrough analgesia, self-reported pain scores at rest and during movement at 24 and 48 hours after surgery, adverse effects of analgesia, complications, and length of stay. There were 26 patients identified who underwent TKR between June 4, 2020, and June 4, 2022, and 25 patients who underwent THR with the same conditions. It was identified that patients who underwent traditional spinal anaesthesia with the addition of ketamine for elective hip- or knee arthroplasty had a lower mean total OME in the 48 hours immediately post-spinal anaesthesia yet had a shorter time to breakthrough analgesia administration. The proposed mechanism of action for intrathecal ketamine as an additive to traditional spinal anaesthesia for elective hip- or knee arthroplasty is that it may prolong and attenuate the analgesic effect of traditional spinal anaesthesia. There were no significant differences identified in comparing the efficacy and safety of adding intrathecal ketamine to spinal anaesthesia for hip- or knee arthroplasty with spinal anaesthesia for hip- or knee arthroplasty without intrathecal ketamine.Keywords: anaesthesia, spinal, intra-thecal, ketamine, spinal-morphine, bupivacaine
Procedia PDF Downloads 523478 Analgesic Efficacy of IPACK Block in Primary Total Knee Arthroplasty (90 CASES)
Authors: Fedili Benamar, Beloulou Mohamed Lamine, Ouahes Hassane, Ghattas Samir
Abstract:
Background and aims: Peripheral regional anesthesia has been integrated into most analgesia protocols for total knee arthroplasty which considered among the most painful surgeries with a huge potential for chronicization. The adductor canal block (ACB) has gained popularity. Similarly, the IPACK block has been described to provide analgesia of the posterior knee capsule. This study aimed to evaluate the analgesic efficacy of this block in patients undergoing primary PTG. Methods: 90 patients were randomized to receive either an IPACK, an anterior sciatic block, or a sham block (30 patients in each group + multimodal analgesia and a catheter in the KCA adductor canal). GROUP 1 KCA GROUP 2 KCA+BSA GROUP 3 KCA+IPACK The analgesic blocks were done under echo-guidance preoperatively respecting the safety rules, the dose administered was 20 cc of ropivacaine 0.25% was used. We were to assess posterior knee pain 6 hours after surgery. Other endpoints included quality of recovery after surgery, pain scores, opioid requirements (PCA morphine)(EPI info 7.2 analysis). Results: -groups were matched -A predominance of women (4F/1H). -average age: 68 +/-7 years -the average BMI =31.75 kg/m2 +/- 4. -70% of patients ASA2 ,20% ASA3. -The average duration of the intervention: 89 +/- 19 minutes. -Morphine consumption (PCA) significantly higher in group 1 (16mg) & group 2 (8mg) group 3 (4mg) - The groups were matched . -There was a correlation between the use of the ipack block and postoperative pain Conclusions :In a multimodal analgesic protocol, the addition of IPACK block decreased pain scores and morphine consumption ,Keywords: regional anesthesia, analgesia, total knee arthroplasty, the adductor canal block (acb), the ipack block, pain
Procedia PDF Downloads 733477 Value of Unilateral Spinal Anaesthesia For Hip Fracture Surgery In The Elderly (75 Cases)
Authors: Fedili Benamar, Beloulou Mohamed Lamine, Ouahes Hassane, Ghattas Samir
Abstract:
Background and aims: While in Western countries, unilateral spinal anesthesia has been widely practiced for a long time, it remains little known in the local anesthesia community, and has not been the object of many studies. However, it is a simple, practical and effective technique. Our objective was to evaluate this practice in emergency anesthesia management in frail patients and to compare it with conventional spinal anesthesia. Methods: This is a prospective, observational, comparative study between hypobaric unilateral and conventional spinal anaesthesia for hip fracture surgery carried out in the operating room of the university military hospital of Staoueli. The work was spread over of 12-month period from 2019 to 2020. The parameters analyzed were hemodynamic variations, vasopressor use, block efficiency, postoperative adverse events, and postoperative morphine consumption. Results: -75 cases (mean age 72±14 years) -Group1= 41 patients (54.6%) divided into (ASA1=14.6% ASA2=60.98% ASA3=24.39%) single shoot spinal anaesthesia -Group2= 34 patients (45.3%) divided into (ASA1=2.9%, ASA2=26.4% ASA3=61.7%, ASA4=8.8%) unilateral hypobaric spinal anesthesia. -Hemodynamic variations were more severe in group 1 (51% hypotension) compared to 30% in group 2 RR=1.69 and odds ratio=2.4 -these variations were more marked in the ASA3 subgroup (group 1=70% hypotension versus group 2=30%) with an RR=2.33 and an odds ratio=5.44 -39% of group 1 required vasoactive drugs (15mg +/- 11) versus 32% of group 2 (8mg+/- 6.49) - no difference in the use of morphine in post-op. Conclusions: Within the limits of the population studied, this work demonstrates the clinical value of unilateral spinal anesthesia in ortho-trauma surgery in the frail patient.Keywords: spinal anaesthesia, vasopressor, morphine, hypobaric unilateral spinal anesthesia, ropivacaine, hip surgery, eldery, hemodynamic
Procedia PDF Downloads 743476 Effects of Different Types of Perioperative Analgesia on Minimal Residual Disease Development After Colon Cancer Surgery
Authors: Lubomir Vecera, Tomas Gabrhelik, Benjamin Tolmaci, Josef Srovnal, Emil Berta, Petr Prasil, Petr Stourac
Abstract:
Cancer is the second leading cause of death worldwide and colon cancer is the second most common type of cancer. Currently, there are only a few studies evaluating the effect of postoperative analgesia on the prognosis of patients undergoing radical colon cancer surgery. Postoperative analgesia in patients undergoing colon cancer surgery is usually managed in two ways, either with strong opioids (morphine, piritramide) or epidural analgesia. In our prospective study, we evaluated the effect of postoperative analgesia on the presence of circulating tumor cells or minimal residual disease after colon cancer surgery. A total of 60 patients who underwent radical colon cancer surgery were enrolled in this prospective, randomized, two-center study. Patients were randomized into three groups, namely piritramide, morphine and postoperative epidural analgesia. We evaluated the presence of carcinoembryonic antigen (CEA) and cytokeratin 20 (CK-20) mRNA positive circulating tumor cells in peripheral blood before surgery, immediately after surgery, on postoperative day two and one month after surgery. The presence of circulating tumor cells was assessed by quantitative real-time reverse transcriptase-polymerase chain reaction (qRT-PCR). In the priritramide postoperative analgesia group, the presence of CEA mRNA positive cells was significantly lower on a postoperative day two compared to the other groups (p=0.04). The value of CK-20 mRNA positive cells was the same in all groups on all days. In all groups, both types of circulating tumor cells returned to normal levels one month after surgery. Demographic and baseline clinical characteristics were similar in all groups. Compared with morphine and epidural analgesia, piritramide significantly reduces the amount of CEA mRNA positive circulating tumor cells after radical colon cancer surgery.Keywords: cancer progression, colon cancer, minimal residual disease, perioperative analgesia.
Procedia PDF Downloads 1883475 Efficient Signal Detection Using QRD-M Based on Channel Condition in MIMO-OFDM System
Authors: Jae-Jeong Kim, Ki-Ro Kim, Hyoung-Kyu Song
Abstract:
In this paper, we propose an efficient signal detector that switches M parameter of QRD-M detection scheme is proposed for MIMO-OFDM system. The proposed detection scheme calculates the threshold by 1-norm condition number and then switches M parameter of QRD-M detection scheme according to channel information. If channel condition is bad, the parameter M is set to high value to increase the accuracy of detection. If channel condition is good, the parameter M is set to low value to reduce complexity of detection. Therefore, the proposed detection scheme has better trade off between BER performance and complexity than the conventional detection scheme. The simulation result shows that the complexity of proposed detection scheme is lower than QRD-M detection scheme with similar BER performance.Keywords: MIMO-OFDM, QRD-M, channel condition, BER
Procedia PDF Downloads 3703474 Reduced Complexity of ML Detection Combined with DFE
Authors: Jae-Hyun Ro, Yong-Jun Kim, Chang-Bin Ha, Hyoung-Kyu Song
Abstract:
In multiple input multiple output-orthogonal frequency division multiplexing (MIMO-OFDM) systems, many detection schemes have been developed to improve the error performance and to reduce the complexity. Maximum likelihood (ML) detection has optimal error performance but it has very high complexity. Thus, this paper proposes reduced complexity of ML detection combined with decision feedback equalizer (DFE). The error performance of the proposed detection scheme is higher than the conventional DFE. But the complexity of the proposed scheme is lower than the conventional ML detection.Keywords: detection, DFE, MIMO-OFDM, ML
Procedia PDF Downloads 6103473 Cigarette Smoke Detection Based on YOLOV3
Abstract:
In order to satisfy the real-time and accurate requirements of cigarette smoke detection in complex scenes, a cigarette smoke detection technology based on the combination of deep learning and color features was proposed. Firstly, based on the color features of cigarette smoke, the suspicious cigarette smoke area in the image is extracted. Secondly, combined with the efficiency of cigarette smoke detection and the problem of network overfitting, a network model for cigarette smoke detection was designed according to YOLOV3 algorithm to reduce the false detection rate. The experimental results show that the method is feasible and effective, and the accuracy of cigarette smoke detection is up to 99.13%, which satisfies the requirements of real-time cigarette smoke detection in complex scenes.Keywords: deep learning, computer vision, cigarette smoke detection, YOLOV3, color feature extraction
Procedia PDF Downloads 873472 An Architecture for New Generation of Distributed Intrusion Detection System Based on Preventive Detection
Authors: H. Benmoussa, A. A. El Kalam, A. Ait Ouahman
Abstract:
The design and implementation of intrusion detection systems (IDS) remain an important area of research in the security of information systems. Despite the importance and reputation of the current intrusion detection systems, their efficiency and effectiveness remain limited as they should include active defense approach to allow anticipating and predicting intrusions before their occurrence. Consequently, they must be readapted. For this purpose we suggest a new generation of distributed intrusion detection system based on preventive detection approach and using intelligent and mobile agents. Our architecture benefits from mobile agent features and addresses some of the issues with centralized and hierarchical models. Also, it presents advantages in terms of increasing scalability and flexibility.Keywords: Intrusion Detection System (IDS), preventive detection, mobile agents, distributed architecture
Procedia PDF Downloads 5833471 Video Based Ambient Smoke Detection By Detecting Directional Contrast Decrease
Authors: Omair Ghori, Anton Stadler, Stefan Wilk, Wolfgang Effelsberg
Abstract:
Fire-related incidents account for extensive loss of life and material damage. Quick and reliable detection of occurring fires has high real world implications. Whereas a major research focus lies on the detection of outdoor fires, indoor camera-based fire detection is still an open issue. Cameras in combination with computer vision helps to detect flames and smoke more quickly than conventional fire detectors. In this work, we present a computer vision-based smoke detection algorithm based on contrast changes and a multi-step classification. This work accelerates computer vision-based fire detection considerably in comparison with classical indoor-fire detection.Keywords: contrast analysis, early fire detection, video smoke detection, video surveillance
Procedia PDF Downloads 4473470 Intrusion Detection Techniques in NaaS in the Cloud: A Review
Authors: Rashid Mahmood
Abstract:
The network as a service (NaaS) usage has been well-known from the last few years in the many applications, like mission critical applications. In the NaaS, prevention method is not adequate as the security concerned, so the detection method should be added to the security issues in NaaS. The authentication and encryption are considered the first solution of the NaaS problem whereas now these are not sufficient as NaaS use is increasing. In this paper, we are going to present the concept of intrusion detection and then survey some of major intrusion detection techniques in NaaS and aim to compare in some important fields.Keywords: IDS, cloud, naas, detection
Procedia PDF Downloads 3203469 Multichannel Object Detection with Event Camera
Authors: Rafael Iliasov, Alessandro Golkar
Abstract:
Object detection based on event vision has been a dynamically growing field in computer vision for the last 16 years. In this work, we create multiple channels from a single event camera and propose an event fusion method (EFM) to enhance object detection in event-based vision systems. Each channel uses a different accumulation buffer to collect events from the event camera. We implement YOLOv7 for object detection, followed by a fusion algorithm. Our multichannel approach outperforms single-channel-based object detection by 0.7% in mean Average Precision (mAP) for detection overlapping ground truth with IOU = 0.5.Keywords: event camera, object detection with multimodal inputs, multichannel fusion, computer vision
Procedia PDF Downloads 273468 Securing Web Servers by the Intrusion Detection System (IDS)
Authors: Yousef Farhaoui
Abstract:
An IDS is a tool which is used to improve the level of security. We present in this paper different architectures of IDS. We will also discuss measures that define the effectiveness of IDS and the very recent works of standardization and homogenization of IDS. At the end, we propose a new model of IDS called BiIDS (IDS Based on the two principles of detection) for securing web servers and applications by the Intrusion Detection System (IDS).Keywords: intrusion detection, architectures, characteristic, tools, security, web server
Procedia PDF Downloads 4183467 Suggestion for Malware Detection Agent Considering Network Environment
Authors: Ji-Hoon Hong, Dong-Hee Kim, Nam-Uk Kim, Tai-Myoung Chung
Abstract:
Smartphone users are increasing rapidly. Accordingly, many companies are running BYOD (Bring Your Own Device: Policies to bring private-smartphones to the company) policy to increase work efficiency. However, smartphones are always under the threat of malware, thus the company network that is connected smartphone is exposed to serious risks. Most smartphone malware detection techniques are to perform an independent detection (perform the detection of a single target application). In this paper, we analyzed a variety of intrusion detection techniques. Based on the results of analysis propose an agent using the network IDS.Keywords: android malware detection, software-defined network, interaction environment, android malware detection, software-defined network, interaction environment
Procedia PDF Downloads 4333466 Improved Skin Detection Using Colour Space and Texture
Authors: Medjram Sofiane, Babahenini Mohamed Chaouki, Mohamed Benali Yamina
Abstract:
Skin detection is an important task for computer vision systems. A good method for skin detection means a good and successful result of the system. The colour is a good descriptor that allows us to detect skin colour in the images, but because of lightings effects and objects that have a similar colour skin, skin detection becomes difficult. In this paper, we proposed a method using the YCbCr colour space for skin detection and lighting effects elimination, then we use the information of texture to eliminate the false regions detected by the YCbCr colour skin model.Keywords: skin detection, YCbCr, GLCM, texture, human skin
Procedia PDF Downloads 4593465 Analysis of Pharmaceuticals in Influents of Municipal Wastewater Treatment Plants in Jordan
Authors: O. A. Al-Mashaqbeh, A. M. Ghrair, D. Alsafadi, S. S. Dalahmeh, S. L. Bartelt-Hunt, D. D. Snow
Abstract:
Grab samples were collected in the summer to characterize selected pharmaceuticals and personal care products (PPCPs) in the influent of two wastewater treatment plants (WWTPs) in Jordan. Liquid chromatography tandem mass spectrometry (LC–MS/MS) was utilized to determine the concentrations of 18 compounds of PPCPs. Among all of the PPCPs analyzed, eight compounds were detected in the influent samples (1,7-dimethylxanthine, acetaminophen, caffeine, carbamazepine, cotinine, morphine, sulfamethoxazole and trimethoprim). However, five compounds (amphetamine, cimetidine, diphenhydramine, methylenedioxyamphetamine (MDA) and sulfachloropyridazine) were not detected in collected samples (below the detection limits <0.005 µg/l). Moreover, the results indicated that the highest concentration levels detected in collected samples were caffeine, acetaminophen, 1,7-dimethylxanthine, cotinine and carbamazepine at concentration of 182.5 µg/L, 28.7 µg/l, 7.47 µg/l, 4.67 µg/l and 1.54 µg/L, respectively. In general, most of compounds concentrations measured in wastewater in Jordan are within the range for wastewater previously reported in India wastewater except caffeine.Keywords: pharmaceuticals, personal care products, wastewater, Jordan
Procedia PDF Downloads 3313464 Real-Time Detection of Space Manipulator Self-Collision
Authors: Zhang Xiaodong, Tang Zixin, Liu Xin
Abstract:
In order to avoid self-collision of space manipulators during operation process, a real-time detection method is proposed in this paper. The manipulator is fitted into a cylinder enveloping surface, and then the detection algorithm of collision between cylinders is analyzed. The collision model of space manipulator self-links can be detected by using this algorithm in real-time detection during the operation process. To ensure security of the operation, a safety threshold is designed. The simulation and experiment results verify the effectiveness of the proposed algorithm for a 7-DOF space manipulator.Keywords: space manipulator, collision detection, self-collision, the real-time collision detection
Procedia PDF Downloads 4693463 Iris Detection on RGB Image for Controlling Side Mirror
Authors: Norzalina Othman, Nurul Na’imy Wan, Azliza Mohd Rusli, Wan Noor Syahirah Meor Idris
Abstract:
Iris detection is a process where the position of the eyes is extracted from the face images. It is a current method used for many applications such as for security purpose and drowsiness detection. This paper proposes the use of eyes detection in controlling side mirror of motor vehicles. The eyes detection method aims to make driver easy to adjust the side mirrors automatically. The system will determine the midpoint coordinate of eyes detection on RGB (color) image and the input signal from y-coordinate will send it to controller in order to rotate the angle of side mirror on vehicle. The eye position was cropped and the coordinate of midpoint was successfully detected from the circle of iris detection using Viola Jones detection and circular Hough transform methods on RGB image. The coordinate of midpoint from the experiment are tested using controller to determine the angle of rotation on the side mirrors.Keywords: iris detection, midpoint coordinates, RGB images, side mirror
Procedia PDF Downloads 4233462 Analgesic and Anti-inflammatoryactivities of Camel Thorn in Experimental Animals
Authors: Abdelkader H. El Debani, Huda Gargoum, Awad G. Abdellatif
Abstract:
The aim of this study is to investigate analgesic and the anti-inflammatory effects Camel Thorn Extract (CTE) in rodents. Male albino mice weighing 20-25 gm. were divided into different groups each of 8 mice. The control was given normal saline i. p., the first group was given normal saline i. p. the 2nd, 3rd, 4th, groups received different doses of CTE (330, 660, and 1300 mg/kg) respectively and the 6th group received 5mg/kg of morphine i. p. All groups (except the control group) were given acetic acid 40 min after receiving the different treatment. The number of writhes was recorded 5 min after acetic acid injection for 15 min and the % of inhibition of writhing were calculated. Different groups of rats weighing 180- 220 gm., were divided into three groups each of 5 rats. At the beginning, the volumes of the right and left paw in animals were measured by using of the plethysmometer. The 1st group was given 660 mg /kg i. p. of CTE, the 2nd group received indomethacin (5 mg/kg i. p.). One hour later, edema was induced by sub planter injection of 0.1 ml of 1 % freshly prepared suspension of carrageenan into the right hind paws of the rats. The volume of the injected paws and contra-lateral paws were measured at 0, 0.5, 1, 2, 3, 4, and 5 hours using plethysmometer. The volume of the left paw of the rat was subtracted from the volume of the right paw of the same animal. Our results showed that 330,660 and 1300 mg/kg produced 14, 49 and 84%of inhibition of writhes, indicating that CTE has a strong analgesic activity. Our data also showed that the % of inhibition of edema at 30, 60, 120, 180, and 240 min was 14,51,71,61, and 56% in the animals given camel thorn extract whereas these figures in animals given endomethacin were 14, 24, 54, 52, and 54%. These results indicate that camel thorn has anti-inflammatory activities. The mechanism of analgesic and anti-inflammatory activities needs further investigations.Keywords: camel thorn, imdomethacin, morphine, pharmaceutical medicine
Procedia PDF Downloads 2433461 Automatic Vehicle Detection Using Circular Synthetic Aperture Radar Image
Authors: Leping Chen, Daoxiang An, Xiaotao Huang
Abstract:
Automatic vehicle detection using synthetic aperture radar (SAR) image has been widely researched, as well as using optical remote sensing images. However, most researches treat the detection as an independent problem, failing to make full use of SAR data information. In circular SAR (CSAR), the two long borders of vehicle will shrink if the imaging surface is set higher than the reference one. Based on above variance, an automatic vehicle detection using CSAR image is proposed to enhance detection ability under complex environment, such as vehicles’ closely packing, which confuses the detector. The detection method uses the multiple images generated by different height plane to obtain an energy-concentrated image for detecting and then uses the maximally stable extremal regions method (MSER) to detect vehicles. A result of vehicles’ detection is given to verify the effectiveness and correctness of proposed method.Keywords: circular SAR, vehicle detection, automatic, imaging
Procedia PDF Downloads 3673460 Adaptive CFAR Analysis for Non-Gaussian Distribution
Authors: Bouchemha Amel, Chachoui Takieddine, H. Maalem
Abstract:
Automatic detection of targets in a modern communication system RADAR is based primarily on the concept of adaptive CFAR detector. To have an effective detection, we must minimize the influence of disturbances due to the clutter. The detection algorithm adapts the CFAR detection threshold which is proportional to the average power of the clutter, maintaining a constant probability of false alarm. In this article, we analyze the performance of two variants of adaptive algorithms CA-CFAR and OS-CFAR and we compare the thresholds of these detectors in the marine environment (no-Gaussian) with a Weibull distribution.Keywords: CFAR, threshold, clutter, distribution, Weibull, detection
Procedia PDF Downloads 5883459 Intrusion Detection Techniques in Mobile Adhoc Networks: A Review
Authors: Rashid Mahmood, Muhammad Junaid Sarwar
Abstract:
Mobile ad hoc networks (MANETs) use has been well-known from the last few years in the many applications, like mission critical applications. In the (MANETS) prevention method is not adequate as the security concerned, so the detection method should be added to the security issues in (MANETs). The authentication and encryption is considered the first solution of the MANETs problem where as now these are not sufficient as MANET use is increasing. In this paper we are going to present the concept of intrusion detection and then survey some of major intrusion detection techniques in MANET and aim to comparing in some important fields.Keywords: MANET, IDS, intrusions, signature, detection, prevention
Procedia PDF Downloads 379