Search results for: common bile duct exploration
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6957

Search results for: common bile duct exploration

6957 Duplicated Common Bile Duct: A Recipe for Injury

Authors: David Armany, Matthew Allaway, Preet Gosal, Senarath Edirimanne

Abstract:

A potentially devastating complication of routine laparoscopic cholecystectomy includes iatrogenic bile duct injuries, which represent a stable incidence rate of 0.3% over the past three decades. Whilst related to several relative risks such as surgeon experience and patient factors (older age, male sex), misinterpretation of biliary tree anatomy remains the most common cause, accounting for 80% of iatrogenic Common Bile Duct injuries. Whilst extremely rare, a duplicate common bile duct anomaly remains a potential variation to encounter during biliary surgery, with 30 recognised cases in the worldwide literature, of which type Vb accounts for 4. We report the case of a rare type Vb variation encountered during intra-operative laparoscopic cholecystectomy and confirmed on cholangiogram. To our knowledge, this is the first documented Type Vb case encountered in an Australian population. Given these anomalies are asymptomatic and can perpetuate iatrogenic common bile duct injuries, awareness of all subtypes is crucial. Irrevocably, preoperative Magnetic Resonance Cholangiopancreatography can help recognise these anomalies before the operating theatre; however, their widespread adoption is limited by expensive and availability.

Keywords: duplicated common bile duct, type Vb, cholecystitis, MRCP, cholangiogram, iatrogenic CBD

Procedia PDF Downloads 90
6956 Cost-Effectiveness of Laparoscopic Common Bile Duct Exploration vs. Endoscopic Retrograde Cholangiopancreatography in the Emergency Management of Common Bile Duct Stones

Authors: Tess Howard, Lily Owens, Maneesha De Silva, Russell Hodgson

Abstract:

Purpose: This study aims to evaluate the cost-effectiveness of laparoscopic common bile duct exploration (CBDE) compared to endoscopic retrograde cholangiopancreatography (ERCP) and cholecystectomy for the emergency management of common bile duct (CBD) stones. Methodology: A retrospective case note review was conducted on consecutive patients undergoing emergency management of CBD stones using either CBDE, or ERCP and cholecystectomy at a single centre between January 2014-October 2014. Data on admission and procedural costs, length of hospital stay, postoperative complications and further stone related interventions were analysed. Results: A total of 350 patients were analysed. Among them, 299 patients underwent CBDE at the time of cholecystectomy, while the remaining 51 underwent ERCP either pre-, intra- or post cholecystectomy. CBDE was associated with lower overall costs compared to ERCP with an average hospital stay cost of $13,093 vs $22,930 respectively. This was largely attributed to shorter hospital stays (6.5 vs 10.3 days), decreased need for intensive care unit admission and fewer postoperative interventions within the CBDE group. Notably, single procedure laparoscopic cholecystectomy with CBDE demonstrated decreased operative costs compared to laparoscopic cholecystectomy combined with ERCP pre-/intra- or post-operatively ($3,747 vs. $4,641). Conclusion: Emergent CBDE is a cost-effective alternative to ERCP for managing CBD stones when combined with cholecystectomy. The upfront investment in equipment for CBDE and increased cholecystectomy procedural time is counterbalanced by reduced hospital stay, fewer procedures and subsequent cost savings. Economic considerations, in conjunction with clinical outcomes, should inform the selection of the optimal approach for CBD stone management in emergency settings.

Keywords: choledocolithiasis, management, cost-effectiveness, endoscopic retrograde cholangiopancreatography, ERCP, CBDE, common bile duct exploration

Procedia PDF Downloads 19
6955 Fibrin Glue Reinforcement of Choledochotomy Closure Suture Line for Prevention of Bile Leak in Patients Undergoing Laparoscopic Common Bile Duct Exploration with Primary Closure: A Pilot Study

Authors: Rahul Jain, Jagdish Chander, Anish Gupta

Abstract:

Introduction: Laparoscopic common bile duct exploration (LCBDE) allows cholecystectomy and the removal of common bile duct (CBD) stones to be performed during the same sitting, thereby decreasing hospital stay. CBD exploration through choledochotomy can be closed primarily with an absorbable suture material, but can lead to biliary leakage postoperatively. In this study we tried to find a solution to further lower the incidence of bile leakage by using fibrin glue to reinforce the sutures put on choledochotomy suture line. It has haemostatic and sealing action, through strengthening the last step of the physiological coagulation and biostimulation, which favours the formation of new tissue matrix. Methodology: This study was conducted at a tertiary care teaching hospital in New Delhi, India, from 2011 to 2013. 20 patients with CBD stones documented on MRCP with CBD diameter of 9 mm or more were included in this study. Patients were randomized into two groups namely Group A in which choledochotomy was closed with polyglactin 4-0 suture and suture line reinforced with fibrin glue, and Group ‘B’ in which choledochotomy was closed with polyglactin 4-0 suture alone. Both the groups were evaluated and compared on clinical parameters such as operative time, drain content, drain output, no. of days drain was required, blood loss & transfusion requirements, length of postoperative hospital stay and conversion to open surgery. Results: The operative time for Group A ranged from 60 to 210 min (mean 131.50 min) and Group B 65 to 300 min (mean 140 minutes). The blood loss in group A ranged from 10 to 120 ml (mean 51.50 ml), in group B it ranged from 10 to 200 ml (mean 53.50 ml). In Group A, there was no case of bile leak but there was bile leak in 2 cases in Group B, minimum 0 and maximum 900 ml with a mean of 97 ml and p value of 0.147 with no statistically significant difference in bile leak in test and control groups. The minimum and maximum serous drainage in Group A was nil & 80 ml (mean 11 ml) and in Group B was nil & 270 ml (mean 72.50 ml). The p value came as 0.028 which is statistically significant. Thus serous leakage in Group A was significantly less than in Group B. The drains in Group A were removed from 2 to 4 days (mean: 3 days) while in Group B from 2 to 9 days (mean: 3.9 days). The patients in Group A stayed in hospital post operatively from 3 to 8 days (mean: 5.30) while in Group B it ranged from 3 to 10 days with a mean of 5 days. Conclusion: Fibrin glue application on CBD decreases bile leakage but in statistically insignificant manner. Fibrin glue application on CBD can significantly decrease post operative serous drainage after LCBDE. Fibrin glue application on CBD is safe and easy technique without any significant adverse effects and can help less experienced surgeons performing LCBDE.

Keywords: bile leak, fibrin glue, LCBDE, serous leak

Procedia PDF Downloads 215
6954 Effect of Nicorandil in Bile Duct Ligation-Induced Liver Fibrosis in Rats: Role of Hepatic Stellate Cells

Authors: Y. S. Mohamed, L. A. Ahmed, H. A. Salem, A. M. Agha

Abstract:

Liver Fibrosis is one of the most serious conditions that affect the Egyptian society. In the present study, the effect of nicorandil was investigated in experimentally-induced liver fibrosis by bile duct ligation in rats. Nicorandil (3mg/kg/day) was given orally 24 h after bile duct ligation for 14 days till the end of the experiment. Nicorandil group showed a significant improvement in liver function tests (ALT and ALP) as well as a significant decrease in oxidative stress biomarkers (TBARS and GSH), area of fibrosis and activity of hepatic stellate cells as indicated by decreased expression of alpha smooth muscle actin.Moreover, nicorandil treatment decreased HSCs proliferation due to its inhibitory effects on protein kinase C(PKC) and Platelet derived growth factor (PDGF) . Oral administration of either glibenclamide (10 mg/kg/day)(a KATP channel blocker) or L-NAME (30 mg/kg/day) (an inhibitor of nitric oxide synthase) blocked the protective effects of nicorandil. However, nicorandil and L-NAME treated group showed more or less results similar to that of untreated bile duct ligated group. In conclusion, nicorandil was effective against the development of bile duct ligated-induced liver fibrosis in rats where activation of the NO pathway plays an important role in the protective effect nicorandil.

Keywords: hepatic stellate cells, nicorandil, nitric oxide donor, liver fibrosis

Procedia PDF Downloads 611
6953 Endoscopic Treatment of Patients with Large Bile Duct Stones

Authors: Yuri Teterin, Lomali Generdukaev, Dmitry Blagovestnov, Peter Yartcev

Abstract:

Introduction: Under the definition "large biliary stones," we referred to stones over 1.5 cm, in which standard transpapillary litho extraction techniques were unsuccessful. Electrohydraulic and laser contact lithotripsy under SpyGlass control have been actively applied for the last decade in order to improve endoscopic treatment results. Aims and Methods: Between January 2019 and July 2022, the N.V. Sklifosovsky Research Institute of Emergency Care treated 706 patients diagnosed with choledocholithiasis who underwent biliary stones removed from the common bile duct. Of them, in 57 (8, 1%) patients, the use of a Dormia basket or Biliary stone extraction balloon was technically unsuccessful due to the size of the stones (more than 15 mm in diameter), which required their destruction. Mechanical lithotripsy was used in 35 patients, and electrohydraulic and laser lithotripsy under SpyGlass direct visualization system - in 26 patients. Results: The efficiency of mechanical lithotripsy was 72%. Complications in this group were observed in 2 patients. In both cases, on day one after lithotripsy, acute pancreatitis developed, which resolved on day three with conservative therapy (Clavin-Dindo type 2). The efficiency of contact lithotripsy was in 100% of patients. Complications were not observed in this group. Bilirubin level in this group normalized on the 3rd-4th day. Conclusion: Our study showed the efficacy and safety of electrohydraulic and laser lithotripsy under SpyGlass control in a well-defined group of patients with large bile duct stones.

Keywords: contact lithotripsy, choledocholithiasis, SpyGlass, cholangioscopy, laser, electrohydraulic system, ERCP

Procedia PDF Downloads 80
6952 Diagnosis of Choledocholithiasis with Endosonography

Authors: A. Kachmazova, A. Shadiev, Y. Teterin, P. Yartcev

Abstract:

Introduction: Biliary calculi disease (LCS) still occupies the leading position among urgent diseases of the abdominal cavity, manifesting itself from asymptomatic course to life-threatening states. Nowadays arsenal of diagnostic methods for choledocholithiasis is quite wide: ultrasound, hepatobiliscintigraphy (HBSG), magnetic resonance imaging (MRI), endoscopic retrograde cholangiography (ERCP). Among them, transabdominal ultrasound (TA ultrasound) is the most accessible and routine diagnostic method. Nowadays ERCG is the "gold" standard in diagnosis and one-stage treatment of biliary tract obstruction. However, transpapillary techniques are accompanied by serious postoperative complications (postmanipulative pancreatitis (3-5%), endoscopic papillosphincterotomy bleeding (2%), cholangitis (1%)), the lethality being 0.4%. GBSG and MRI are also quite informative methods in the diagnosis of choledocholithiasis. Small size of concrements, their localization in intrapancreatic and retroduodenal part of common bile duct significantly reduces informativity of all diagnostic methods described above, that demands additional studying of this problem. Materials and Methods: 890 patients with the diagnosis of cholelithiasis (calculous cholecystitis) were admitted to the Sklifosovsky Scientific Research Institute of Hospital Medicine in the period from August, 2020 to June, 2021. Of them 115 people with mechanical jaundice caused by concrements in bile ducts. Results: Final EUS diagnosis was made in all patients (100,0%). In all patients in whom choledocholithiasis diagnosis was revealed or confirmed after EUS, ERCP was performed urgently (within two days from the moment of its detection) as the X-ray operation room was provided; it confirmed the presence of concrements. All stones were removed by lithoextraction using Dormia basket. The postoperative period in these patients had no complications. Conclusions: EUS is the most informative and safe diagnostic method, which allows to detect choledocholithiasis in patients with discrepancies between clinical-laboratory and instrumental methods of diagnosis in shortest time, that in its turn will help to decide promptly on the further tactics of patient treatment. We consider it reasonable to include EUS in the diagnostic algorithm for choledocholithiasis. Disclosure: Nothing to disclose.

Keywords: endoscopic ultrasonography, choledocholithiasis, common bile duct, concrement, ERCP

Procedia PDF Downloads 85
6951 Evaluation of Surgical Site Infection in Bile Spillage Cases Compared to Non Bile Spillage Cases Following Laparoscopic Cholecystectomy

Authors: Ishwor Paudel, Pratima Gautam, Sandeep Bhattarai

Abstract:

Bile spillage occurs frequently during laparoscopic cholecystectomy yet its impact on postoperative outcomes remains unknown. It might not be as innocuous as some surgeons tend to believe and in fact, might be associated with post-operative surgical site infections (SSI). It often leads to patient dissatisfaction, emergency department visits, with subsequent readmission and additional procedures. While some authors found no increase in SSI following bile spillage (BS) compared to non-bile spillage cases, others found bile spillage to be associated with SSI. Therefore we sought to examine whether bile spillage is indeed associated with an increased risk of postoperative wound infections after laparoscopic cholecystectomy. I hypothesize that patients who experience BS during operation, have an increased risk of SSI compared to those who do not. This is a prospective observational study conducted in the Department of Surgery, Patan Hospital over a period of one year. Patients undergoing Laparoscopic cholecystectomy were included and bile spillage, if happened was noted. All cases were followed up for 30 days and SSI was diagnosed as per CDC-defined criteria. Fisher’s test was applied to compare SSI in bile spillage versus non-bile spillage cases. A total of 112 patients were included in the final analysis. Bile spillage occurred in 20 cases and was absent in the rest i.e.92 cases. Among bile spillage cases, SSI was found in 4 cases (20%), whereas in nonbile spillage cases, SSI was found in 8 cases (8.7%). However, it was statistically not significant (p-value>0.05). Eleven (92%) cases were superficial SSI and one was an organ-space infection. No mortality or 30-day readmission. Spillage of Gallbladder content does not lead to an increase in SSIs. However as the rate of SSI is still higher, Surgeons should be careful to avoid iatrogenic gallbladder perforation and in case of bile spillage thorough peritoneal irrigation with normal saline should be done.

Keywords: organ space infection, Laparoscopic cholecystectomy, biliary spillage, surgical site infection

Procedia PDF Downloads 77
6950 The Role of Glyceryl Trinitrate (GTN) in 99mTc-HIDA with Morphine Provocation Scan for the Investigation of Type III Sphincter of Oddi Dysfunction (SOD)

Authors: Ibrahim M Hassan, Lorna Que, Michael Rutland

Abstract:

Type I SOD is usually diagnosed by anatomical imaging such as ultrasound, CT and MRCP. However, the types II and III SOD yield negative results despite the presence of significant symptoms. In particular, the type III is difficult to diagnose due to the absence of significant biochemical or anatomical abnormalities. Nuclear Medicine can aid in this diagnostic dilemma by demonstrating functional changes in the bile flow. Low dose Morphine (0.04mg/Kg) stimulates the tone of the sphincter of Oddi (SO) and its usefulness has been shown in diagnosing SOD by causing a delay in bile flow when compared to a non morphine provoked - baseline scan. This work expands on that process by using sublingual GTN at 60 minutes post tracer and morphine injection to relax the SO and induce an improvement in bile outflow, and in some cases show immediate relief of morphine induced abdominal pain. The criteria for positive SOD are as follows: if during the first hour of the morphine provocation showed (1) delayed intrahepatic biliary ducts tracer accumulation; plus (2) delayed appearance but persistent retention of activity in the common bile duct, and (3) delayed bile flow into the duodenum. In addition, patients who required GTN within the first hour to relieve abdominal pain were regarded as highly supportive of the diagnosis. Retrospective analysis of 85 patients (pts) (78F and 6M) referred for suspected SOD (type III) who had been intensively investigated because of recurrent right upper quadrant or abdominal pain post cholecystectomy. 99mTc-HIDA scan with morphine-provocation is performed followed by GTN at 60 minutes post tracer injection and a further thirty minutes of dynamic imaging are acquired. 30 pts were negative. 55 pts were regarded as positive for SOD and 38/55 (60%) of these patients with an abnormal result were further evaluated with a baseline 99mTc-HIDA. As expected, all 38 pts showed better bile flow characteristics than during the morphine provocation. 20/55 (36%) patients were treated by ERCP sphincterotomy and the rest were managed conservatively by medical therapy. In all cases regarded as positive for SOD, the sublingual GTN at 60 minutes showed immediate improvement in bile flow. 11/55(20%) who developed severe post-morphine abdominal pain were relieved by GTN almost instantaneously. We propose that GTN is a useful agent in the diagnosis of SOD when performing 99mTc-HIDA scan and that the satisfactory response to the sublingual GTN could offer additional information in patients who have severe pain at the time the procedure or when presenting to the emergency unit because of biliary pain. And also in determining whether a trial of medical therapy may be used before considering surgery.

Keywords: GTN, HIDA, MORPHINE, SOD

Procedia PDF Downloads 305
6949 Bile Salt Induced Microstructural Changes of Gemini Surfactant Micelles

Authors: Vijaykumar Patel, P. Bahadur

Abstract:

Microstructural evolution of a cationic gemini surfactant 12-4-12 micelles in the presence of bile salts has been investigated using different techniques. A negative value of interaction parameter evaluated from surface tension measurements is a signature of strong synergistic interaction between oppositely charged surfactants. Both the bile salts compete with each other in inducing the micellar transition of 12-4-12 micelles depending on their hydrophobicity. Viscosity measurements disclose that loading of bile salts induces morphological changes in 12-4-12 micelles; sodium deoxycholate is more efficient in altering the aggregation behaviour of 12-4-12 micelles compared to sodium cholate and presents pronounced increase in viscosity and micellar growth which is suppressed at elevated temperatures. A remarkable growth of 12-4-12 micelles in the presence of sodium deoxycholate at low pH has been ascribed to the solubilization of bile acids formed in acidic medium. Small angle neutron scattering experiments provided size and shape of 12-4-12/bile salt mixed micelles are explicated on the basis of hydrophobicity of bile salts. The location of bile salts in micelle was determined from nuclear overhauser effect spectroscopy. The present study characterizes 12-4-12 gemini-bile salt mixed systems which significantly enriches our knowledge, and such a structural transition provides an opportunity to use these bioamphiphiles as delivery vehicles and in some pharmaceutical formulations.

Keywords: gemini surfactants, bile salts, SANS (small angle neutron scattering), NOESY (nuclear overhauser effect spectroscopy)

Procedia PDF Downloads 151
6948 Effect of Copper Particle on the PD Characteristics in a Coaxial Duct with Mixture of SF6 (10%) and N2 (90%) Gases

Authors: B. Rajesh Kamath, J. Sundara Rajan, M. K. Veeraiah, M. Z. Kurian

Abstract:

Insulation performance of a gas insulated system is severely affected by particle contaminants. These metallic particles adversely affect the characteristics of insulating system. These particles can produce surface charges due to partial discharge activities. These particles which are free to move enhance the local electric fields. This paper deals with the influence of conducting particle placed in a co-axial duct on the discharge characteristics of gas mixtures. Co-axial duct placed in a high pressure chamber is used for the purpose. A gas pressure of 0.1, 0.2 and 0.3 MPa have been considered with a 10:90 SF6 and N2 gas mixtures. The 2D and 3D histograms of clean duct and duct with copper particle are discussed in this paper.

Keywords: coaxial duct, gas insulated system, gas mixtures, metallic particle, partial discharges, histograms

Procedia PDF Downloads 400
6947 Numerical Investigation of Divergence and Rib Orientation Effects on Thermal Performance in a Divergent Duct, as an Application of Inner Cooling of Turbine Blades

Authors: Heidar Jafarizadeh, Hossein Keshtkar, Ahmad Sohankar

Abstract:

Heat transfer and turbulent flow structure have been studied in a divergent ribbed duct with a varying duct geometry with Reynolds numbers of 7000 to 90000 using numerical methods. In this study, we confirmed our numerical results of a ribbed duct with an Initial slope of zero to 3 degree by comparing them to experimental data we had and investigated the impact of the ducts divergence on heat transfer and flow pattern in the 2-dimensional flow. Then we investigated the effect of tilting the ribs, on heat transfer and flow behavior. We achieved this by changing the ribs angles from a range of 40 to 75 degrees in a divergent duct and simulated the flow in 3-dimensions. Our results show that with an increase in duct divergence, heat transfer increases linearly and the coefficient of friction increases exponentially. As the results show, a duct with a divergence angle of 1.5 degree presents better thermal performance in comparison with all the angle range’s we studied. Besides, a ribbed duct with 40 degree rib orientation had the best thermal performance considering the simultaneous effects of pressure drop and heat transfer which were imposed on it.

Keywords: divergent ribbed duct, heat transfer, thermal performance, turbulent flow structure

Procedia PDF Downloads 302
6946 Some Probiotic Traits of Lactobacillus Strains Isolated from Pollen

Authors: Hani Belhadj, Daoud Harzallah, Seddik Khennouf, Saliha Dahamna, Mouloud Ghadbane

Abstract:

In this study, Lactobacillus strains isolated from pollen were identified by means of phenotypic and genotypic methods, At pH 2, most strains proved to be acid resistants, with losses in cell viability ranging from 0.77 to 4.04 Log orders. In addition, at pH 3 all strains could grew and resist the acidic conditions, with losses in cell viability ranging from 0.40 to 3.61 Log orders. It seems that, 0.3% and 0.5% of bile salts does not affect greatly the survival of most strains, excluding Lactobacillus sp. BH1398. Survival ranged from 81.0±3.5 to 93.5±3.9%. In contrast, in the presence of 1.0% bile salts, survival of five strains was decreased by more than 50%. Lactobacillus fermentum BH1509 was considered the most tolerant strain (77.5% for 1% bile) followed by Lactobacillus plantarum BH1541 (59.9% for 1% bile). Furthermore, all strains were resistant to colistine, clindamycine, chloramphenicol, and ciprofloxacine, but most of the strains were susceptible to Peniciline, Oxacillin, Oxytetracyclin, and Amoxicillin. Functionally interesting Lactobacillus isolates may be used in the future as probiotic cultures for manufacturing fermented foods and as bioactive delivery systems.

Keywords: probiotics, lactobacillus, pollen, bile, acid tolerance

Procedia PDF Downloads 420
6945 Numerical Study of Heat Transfer in Square Duct with Turbulators

Authors: M. H. Alhajeri, Hamad M. Alhajeri, A. H. Alenezi

Abstract:

Computational fluid dynamics (CFD) investigation of heat transfer in U-duct with turbulators is presented in this paper. The duct passages used to cool internally the blades in gas turbine. The study is focused in the flow behavior and the Nusselt number (Nu) distributions. The model of the u-duct contains two square legs that are connected by 180* turn. Four turbulators are located in each surface of the leg and distributed in a staggered arrangement. The turbulator height and width are equal to 0.1 of the duct width, and the turbulator height is 0.1 of the distance between the turbulators. The Reynolds number (Re) used in this study is 95000 and the inlet velocity is 10 m/s. It was noticed that, after the flow resettles from the interruptions generated by the first turbulator or the turn, the flow construct two eddies, one large and the other is small after and before the turbulator, respectively. The maximum values of the Nu are found at a distance of approximately one turbulator width w before of the flow reattachment point.

Keywords: computational fluid dynamics, CFD, rib, heat transfer, blade

Procedia PDF Downloads 151
6944 Experimental Study of Semitransparent and Opaque Photovoltaic Modules with and without Air Duct

Authors: Sanjay Agrawal, Trapti Varshney, G. N. Tiwari

Abstract:

In this paper, thermal modeling has been developed for photovoltaic PV modules, namely; Case A: semitransparent PV module without duct, Case B: semitransparent PV module with duct, Case C: opaque PV module without duct, Case D: opaque PV module with duct for Delhi, India climatic condition. MATLAB 7.0 software has been used to solve mathematical models of the proposed system. For validation of proposed system, the experimental study has also been carried out for all above four cases, and then comparative analysis of all different type of PV module has been presented. The hybrid PVT module air collectors presented in this study are self sustaining the system and can be used for the electricity generation in remote areas where access of electricity is not economical due to high transmission and distribution losses. It has been found that overall annual thermal energy and exergy gain of semitransparent PV module is higher by 11.6% and7.32% in summer condition and 16.39% and 18% in winter condition respectively as compared to opaque PV module considering same area (0.61 m2) of PV module.

Keywords: semitransparent PV module, overall exergy, overall thermal energy, opaque

Procedia PDF Downloads 437
6943 Survival of Four Probiotic Strains in Acid, Bile Salt and After Spray Drying

Authors: Rawichar Chaipojjana, Suttipong Phosuksirikul, Arunsri Leejeerajumnean

Abstract:

The objective of the study was to select the survival of probiotic strains when exposed to acidic and bile salts condition. Four probiotic strains (Lactobacillus casei subsp. rhamnosus TISTR 047, Lactobacillus casei TISTR 1500, Lactobacillus acidophilus TISTR 1338 and Lactobacillus plantarum TISTR 1465) were cultured in MRS broth and incubated at 35ºC for 15 hours before being inoculated into acidic condition (5 M HCl, pH 2) for 2 hours and bile salt (0.3%, pH 5.8) for 8 hour. The survived probiotics were counted in MRS agar. Among four stains, Lactobacillus casei subsp. rhamnosus TISTR 047 was the highest tolerance specie. Lactobacillus casei subsp. rhamnosus TISTR 047 reduced 6.74±0.07 log CFU/ml after growing in acid and 5.52±0.05 log CFU/ml after growing in bile salt. Then, double emulsion of microorganisms was chosen to encapsulate before spray drying. Spray drying was done with the inlet temperature 170ºC and outlet temperature 80ºC. The results showed that the survival of encapsulated Lactobacillus casei subsp. rhamnosus TISTR 047 after spray drying decreased from 9.63 ± 0.32 to 8.31 ± 0.11 log CFU/ml comparing with non-encapsulated, 9.63 ± 0.32 to 4.06 ± 0.08 log CFU/ml. Therefore, Lactobacillus casei subsp. rhamnosus TISTR 047 would be able to survive in gastrointestinal and spray drying condition.

Keywords: probiotic, acid, bile salt, spray drying

Procedia PDF Downloads 359
6942 Magnetohydrodynamic Flows in a Misaligned Duct under a Uniform Magnetic Field

Authors: Mengqi Zhu, Chang Nyung Kim

Abstract:

This study numerically investigates three-dimensional liquid-metal (LM) magnetohydrodynamic (MHD) flows in a misaligned duct under a uniform magnetic field. The duct consists of two misaligned horizontal channels (one is inflow channel, the other is outflow channel) and one central vertical channel. Computational fluid dynamics simulations are performed to predict the behavior of the MHD flows, using commercial code CFX. In the current study, a case with Hartmann number 1000 is considered. The electromagnetic features of LM MHD flows are elucidated to examine the interdependency of the flow velocity, current density, electric potential, pressure drop and Lorentz force. The results show that pressure decreases linearly along the main flow direction.

Keywords: CFX, liquid-metal magnetohydrodynamic flows, misaligned duct, pressure drop

Procedia PDF Downloads 284
6941 MHD Flow in a Curved Duct with FCI under a Uniform Magnetic Field

Authors: Yue Yan, Chang Nyung Kim

Abstract:

The numerical investigation of the three-dimensional liquid-metal (LM) magnetohydrodynamic (MHD) flows in a curved duct with flow channel insert (FCI) is presented in this paper, based on the computational fluid dynamics (CFD) method. A uniform magnetic field is applied perpendicular to the duct. The interdependency of the flow variables is examined in terms of the flow velocity, current density, electric potential and pressure. The electromagnetic characteristics of the LM MHD flows are reviewed with an introduction of the electric-field component and electro-motive component of the current. The influence of the existence of the FCI on the fluid flow is investigated in detail. The case with FCI slit located near the side layer yields smaller pressure gradient with stable flow field.

Keywords: curved duct, flow channel insert, liquid-metal, magnetohydrodynamic

Procedia PDF Downloads 496
6940 Cholesterol-Lowering Effects of Lactobacillus plantarum Isolated from Northeastern Thai Fermented Vegetable Brassica juncea (L.)

Authors: T. Warinpramote, J. Sanguanjeen, P. Pholphakwaen, S. Kittisorayut, J. Kerdtubtim, S. Palachote, M. Taweechotipatr

Abstract:

Cholesterol is a type of lipid molecule which is the significant risk factor for coronary heart disease. Currently, there are many cholesterol-lowering alternative treatments especially bile salt hydrolase positive lactobacilli. BSH can cleave the peptide linkage of bile salt, which results in removal of the amino acid group from the steroid core and increases production of the new bile acid by using more cholesterol. The purpose of this study was to isolate, and screen probiotic characteristics of lactobacilli from fermented Thai foods and further investigated for their comparative BSH activity. The result showed that 2 of 81 Lactobacillus strains, JPK2-2 and JPK3-2, isolated from Brassica juncea (L.) had significantly exhibited high BSH activity. In addition, these Lactobacillus strains showed their results that the ability to tolerate acid and bile salt. Furthermore, the using of 16S rDNA sequencing for definitive microbial identifications showed that these 2 strains belong to Lactobacillus plantarum. In the future, the L. plantarum with BSH activity strains JPK2-2 and JPK3-2 may be the candidate probiotics for application in functional foods and dairy products to improve in the patient with cardiovascular diseases.

Keywords: Lactobacillus plantarum, probiotics, bile salt hydrolase, cholesterol-lowering, fermented Thai food

Procedia PDF Downloads 156
6939 PIV Measurements of the Instantaneous Velocities for Single and Two-Phase Flows in an Annular Duct

Authors: Marlon M. Hernández Cely, Victor E. C. Baptistella, Oscar M. H. Rodríguez

Abstract:

Particle Image Velocimetry (PIV) is a well-established technique in the field of fluid flow measurement and provides instantaneous velocity fields over global domains. It has been applied to external and internal flows and in single and two-phase flows. Regarding internal flow, works about the application of PIV in annular ducts are scanty. An experimental work is presented, where flow of water is studied in an annular duct of inner diameter of 60 mm and outer diameter of 155 mm and 10.5-m length, with the goal of obtaining detailed velocity measurements. Depending on the flow rates of water, it can be laminar, transitional or turbulent. In this study, the water flow rate was kept at three different values for the annular duct, allowing the analysis of one laminar and two turbulent flows. Velocity fields and statistic quantities of the turbulent flow were calculated.

Keywords: PIV, annular duct, laminar, turbulence, velocity profile

Procedia PDF Downloads 352
6938 Effects of Bile Acids and Lipase Supplementation in Low-Energy Diets on Growth Performance and Meat Quality in Broiler Chickens

Authors: Muhammad Adeel Arshad, Shaukat Ali Bhatti

Abstract:

The study aimed to investigate the effect of bile acids and lipase supplementation in low-energy diets on growth performance and meat quality of broilers. Seven hundred day-old Cobb-500 broiler chicks with an average initial body weight of 45.9 ± 0.3 g were assigned to 5 dietary treatments, with five replications of 28 birds each in a completely randomized design. The five treatments were as follows: (i) HE: broilers received a diet with high energy content; (ii) LE: broilers received a diet with low energy content and energy content reduced by 100 kcal/kg as compared to HE; (iii) LEB: broilers received a diet similar to the LE group supplemented with 300 g/ton bile acids; (iv) LEL: broilers received a diet similar to the LE group supplemented with 180 g/ton lipase enzyme and (v) LEBL: broilers received a diet similar to the LE group supplemented with both 300 g/ton bile acids and 180 g/ton lipase enzyme. The experimental period lasted for 35 days. Broilers fed HE had a lower (P < 0.05) body weight (BW) gain and lower feed intake (1-35 d), but during finisher period (21-35 d), BW gain was similar with other treatments. Feed conversion ratio (FCR) was lower in HE and higher in LEBL group (P < 0.05), while the LE, LEB, and LEL had intermediate values. At 35 d no difference occurred between treatment for water holding capacity and pH of breast and thigh muscles (P > 0.05). The relative weight of pancreas was higher (P < 0.05) in LEB treatment but lower (P < 0.05) in LEL treatment. In conclusion, bile acids and lipase supplementation at 300 g/ton and 150g/ton of feed in low-energy diets respectively had no effect on broiler performance and meat quality. However, FCR was improved in HE treatment.

Keywords: bile acids, energy, enzyme, growth

Procedia PDF Downloads 120
6937 Mooring Analysis of Duct-Type Tidal Current Power System in Shallow Water

Authors: Chul H. Jo, Do Y. Kim, Bong K. Cho, Myeong J. Kim

Abstract:

The exhaustion of oil and the environmental pollution from the use of fossil fuel are increasing. Tidal current power (TCP) has been proposed as an alternative energy source because of its predictability and reliability. By applying a duct and single point mooring (SPM) system, a TCP device can amplify the generating power and keep its position properly. Because the generating power is proportional to cube of the current stream velocity, amplifying the current speed by applying a duct to a TCP system is an effective way to improve the efficiency of the power device. An SPM system can be applied at any water depth and is highly cost effective. Simple installation and maintenance procedures are also merits of an SPM system. In this study, we designed an SPM system for a duct-type TCP device for use in shallow water. Motions of the duct are investigated to obtain the response amplitude operator (RAO) as the magnitude of the transfer function. Parameters affecting the stability of the SPM system such as the fairlead departure angle, current velocity, and the number of clamp weights are analyzed and/or optimized. Wadam and OrcaFlex commercial software is used to design the mooring line.

Keywords: mooring design, parametric analysis, RAO (Response Amplitude Operator), SPM (Single Point Mooring)

Procedia PDF Downloads 289
6936 Antidiabetic Evaluation of Pig (Sus scrofa) Bile on Alloxan-Induced BALB/c Mice

Authors: John Lyndon C. Lunnay

Abstract:

This study discerns to evaluate the antidiabetic efficacy of pig bile on alloxan-induced BALB/c mice. The experimental animals were divided and selected using RCBD into 5 groups (n= 4): T1 (negative control), T2 (1ml/kg), T3 (2ml/kg), T4 (3ml/kg) and T5 (Glibenclamide). Hyperglycemia was induced by injecting 1% alloxan monohydrate intraperitoneally. A glucose tolerance test was performed using a 2g/kg glucose solution, and blood glucose levels were measured at different time intervals. 14 days of monitoring was also done to ensure effectivity and efficacy of the different treatments. Bodyweight was also determined. Results show that administration of treatments on test animals significantly reverted the blood glucose levels of mice in 60 minutes and 120 minutes using an oral glucose tolerance test. After 14 days of monitoring, normal blood glucose levels were seen significantly on T2 (1ml/kg), T3 (2ml/kg), T4 (3ml/kg), and T5 (Glibenclamide), which only suggests the efficacy of pig bile on lowering glucose levels on alloxan-induced diabetic mice. Bodyweight analysis shows no significant difference. Duncan’s multiple range test (DMRT) shows comparable efficacy and effectivity between T4 (3ml/kg) and T5 (Glibenclamide) on lowering BGL at different day and time intervals.

Keywords: pig bile, BALB/c mice, blood glucose, Gllibenclamide

Procedia PDF Downloads 148
6935 Mixed Convective Heat Transfer in Water-Based Al2O3 Nanofluid in Horizontal Rectangular Duct

Authors: Nur Irmawati, H. A. Mohammed

Abstract:

In the present study, mixed convection in a horizontal rectangular duct using Al2O3 is numerically investigated. The effects of different Rayleigh number, Reynolds number and radiation on flow and heat transfer characteristics were studied in detail. This study covers Rayleigh number in the range of 2×106≤Ra≤2×107 and Reynolds number in the range of 100≤Re≤1100. Results reveal that the Nusselt number increases as Reynolds and Rayleigh numbers increase. It was also found that the dimensionless temperature distribution increases as Rayleigh number increases.

Keywords: numerical simulation, mixed convection, horizontal rectangular duct, nanofluids

Procedia PDF Downloads 376
6934 CFD Modeling of Air Stream Pressure Drop inside Combustion Air Duct of Coal-Fired Power Plant with and without Airfoil

Authors: Pakawhat Khumkhreung, Yottana Khunatorn

Abstract:

The flow pattern inside rectangular intake air duct of 300 MW lignite coal-fired power plant is investigated in order to analyze and reduce overall inlet system pressure drop. The system consists of the 45-degree inlet elbow, the flow instrument, the 90-degree mitered elbow and fans, respectively. The energy loss in each section can be determined by Bernoulli’s equation and ASHRAE standard table. Hence, computational fluid dynamics (CFD) is used in this study based on Navier-Stroke equation and the standard k-epsilon turbulence modeling. Input boundary condition is 175 kg/s mass flow rate inside the 11-m2 cross sectional duct. According to the inlet air flow rate, the Reynolds number of airstream is 2.7x106 (based on the hydraulic duct diameter), thus the flow behavior is turbulence. The numerical results are validated with the real operation data. It is found that the numerical result agrees well with the operating data, and dominant loss occurs at the flow rate measurement device. Normally, the air flow rate is measured by the airfoil and it gets high pressure drop inside the duct. To overcome this problem, the airfoil is planned to be replaced with the other type measuring instrument, such as the average pitot tube which generates low pressure drop of airstream. The numerical result in case of average pitot tube shows that the pressure drop inside the inlet airstream duct is decreased significantly. It should be noted that the energy consumption of inlet air system is reduced too.

Keywords: airfoil, average pitot tube, combustion air, CFD, pressure drop, rectangular duct

Procedia PDF Downloads 157
6933 Economical Analysis of Optimum Insulation Thickness for HVAC Duct

Authors: D. Kumar, S. Kumar, A. G. Memon, R. A. Memon, K. Harijan

Abstract:

A considerable amount of energy is usually lost due to compression of insulation in Heating, ventilation, and air conditioning (HVAC) duct. In this paper, the economic impact of compression of insulation is estimated. Relevant mathematical models were used to estimate the optimal thickness at the points of compression. Furthermore, the payback period is calculated for the optimal thickness at the critical parts of supply air duct (SAD) and return air duct (RAD) considering natural gas (NG) and liquefied petroleum gas (LPG) as fuels for chillier operation. The mathematical model is developed using preliminary data obtained for an HVAC system of a pharmaceutical company. The higher heat gain and cooling loss, due to compression of thermal insulation, is estimated using relevant heat transfer equations. The results reveal that maximum energy savings (ES) in SAD is 34.5 and 40%, while in RAD is 22.9% and 29% for NG and LPG, respectively. Moreover, the minimum payback period (PP) for SAD is 2 and 1.6years, while in RAD is 4.3 and 2.7years for NG and LPG, respectively. The optimum insulation thickness (OIT) corresponding to maximum ES and minimum PP is estimated to be 35 and 42mm for SAD, while 30 and 38mm for RAD in case of NG and LPG, respectively.

Keywords: optimum insulation thickness, life cycle cost analysis, payback period, HVAC system

Procedia PDF Downloads 216
6932 Simulation and Experimentation of Solar Thermal Collector for Air Heating System Using Dynamic Ribs

Authors: Nishitha Chowdary, Prabhav Dwivedi

Abstract:

Solar radiation (or insolation) is responsible for 174 petawatts (PW) of energy reaching the Earth's atmosphere. About one-third of this is reflected in space. Solar energy is by far the most abundant source of energy on Earth. In this study to use solar energy to the fullest in a solar air heater, An analysis of a solar air heater duct roughened with fixed cylindrical ribs in 3-D has been done using CFD. These fixed cylindrical ribs have a uniform circular cross-section and are placed in transverse in-line and staggered arrangements. The orientation of ribs has been fixed and is perpendicular to the in-flow direction. Cylindrical ribs are arranged periodically with fixed pitch; therefore, one pitch length is only considered in the present study. Validation has been done with smooth as well as with roughened duct and is matched perfectly with the developed correlations. Geometric parameters, namely rib height (e), ranges from 1 to 2 mm and pitch ranges from 10 to 40 mm are used in the present investigation. Thermo-hydraulic performance parameters in terms of average Nusselt number and friction factor have been extracted for Reynolds number ranging 5000—18000 to optimize the performance of roughened duct.

Keywords: cylindrical ribs, solar air heater, thermo-hydraulic performance factor, roughened duct

Procedia PDF Downloads 155
6931 Development of a Web Exploration Support System Focusing on Accumulation of Search Contexts

Authors: T. Yamazaki, R. Onuma, H. Kaminaga, Y. Miyadera, S. Nakamura

Abstract:

Web exploration has increasingly diversified in accordance with the development of browsing environments on the Internet. Moreover, advanced exploration often conducted in intellectual activities such as surveys in research activities. This kind of exploration is conducted for a long period with trials and errors. In such a case, it is extremely important for a user to accumulate the search contexts and understand them. However, existing support systems were not effective enough since most systems could not handle the various factors involved in the exploration. This research aims to develop a novel system to support web exploration focusing on the accumulation of the search contexts. This paper mainly describes the outline of the system. An experiment using the system is also described. Finally, features of the system are discussed based on the results.

Keywords: web exploration context, refinement of search intention, accumulation of context, exploration support, information visualization

Procedia PDF Downloads 309
6930 Heat Transfer and Friction Factor Study for Triangular Duct Solar Air Heater Having Discrete V-Shaped Ribs

Authors: Varun Goel

Abstract:

Solar energy is a good option among renewable energy resources due to its easy availability and abundance. The simplest and most efficient way to utilize solar energy is to convert it into thermal energy and this can be done with the help of solar collectors. The thermal performance of such collectors is poor due to less heat transfer from the collector surface to air. In this work, experimental investigations of single pass solar air heater having triangular duct and provided with roughness element on the underside of the absorber plate. V-shaped ribs are used for investigation having three different values of relative roughness pitch (p/e) ranges from 4-16 for a fixed value of angle of attack (α), relative roughness height (e/Dh) and a relative gap distance (d/x) values are 60°, 0.044 and 0.60 respectively. Result shows that considerable augmentation in heat transfer has been obtained by providing roughness.

Keywords: artificial roughness, solar air heater, triangular duct, V-shaped ribs

Procedia PDF Downloads 452
6929 The Differences between Direct Examination and ELISA Test during the Diagnosis of Fasciolosis in Jaundiced Slaughtered Sheep in Iraq

Authors: Azad A. Meerkhan, Alaa Hani Razak, Bayan M. S. Younis

Abstract:

The efficiency of enzyme-linked immunosorbent assay (ELISA) in sheep infected with Fasciola hepatica was studied. 232 jaundiced sheep among 5208 sheep slaughter in the Duhok abattoir (regardless of the age and gender) between the period of May. 2012 to Oct. 2012 were examined by direct examination (Searching of adult flukes in the bile duct) and by Enzyme-linked immunosorbent assay (ELISA) to detect the prevalence of fascioliasis in the studied population which showed a high observed infection ratio in Sep. 2012 (12.2%) with the high (ELISA) result of infection in May. 2012 (25.36%). Significant differences were found between the two ways in all of the months with the highest difference in May. 2012 and the net deference between the both ways was 6.91%.

Keywords: fascioliasis, Fasciola hepatica, layers, liver fluk, ELISA, direct examination

Procedia PDF Downloads 322
6928 Influence of Flame-Holder on Existence Important Parameters in a Duct Combustion Simulator

Authors: Mohammad Mahdi Doustdar, Mohammad Mojtahedpoor

Abstract:

The effects of flame-holder position, the ratio of flame holder diameter to combustion chamber diameter and injection angle on fuel propulsive droplets sizing and effective mass fraction have been studied by a cold flow. We named the mass of fuel vapor inside the flammability limit as the effective mass fraction. An empty cylinder as well as a flame-holder which are as a simulator for duct combustion has been considered. The airflow comes into the cylinder from one side and injection operation will be done by four nozzles which are located on the entrance of cylinder. To fulfill the calculations a modified version of KIVA-3V code which is a transient, three-dimensional, multi phase, multi component code for the analysis of chemically reacting flows with sprays, is used.

Keywords: KIVA-3V, flame-holder, duct combustion, effective mass fraction, mean diameter of droplets

Procedia PDF Downloads 622